ANTI-MICROBIAL CONFORM PROTECTIVE FILM 714-575-1100 www.Graffiti-Shield.com Tested by third party to ISO testing standards against most common illness-causing bacteria and coronavirus. Antimicrobial technology is applied to the product; it does not directly protect the user from any exposure to bacteria or viruses, or provide additional health benefits. Pure Zone antimicrobial film contains an active ingredient (silver ions approved by EPA under file number 73148-1-91742). Pure Zone has been tested and proven to reduce Coronavirus by up to 99.87% (after 1 hour) and reduce up to 99.99% of bacteria (after 1 hour) such as: Listeria, Salmonella, Golden Staph, Methicillin-resistant Staphylococcus aureus, and Pseudomonas aeruginosa. It is strongly recommended to practice good hygiene, wash hands regularly, and maintain social distancing as often as possible. During cleaning operations, as well as in the presence of humidity, silver ions are released from the top layer of the film. These ions come into contact with the bacteria, blocking their metabolism and/or interrupting their proliferation mechanism, leading to their destruction When the Anti-Microbial film is manufactured, silver ions encapsulated in a glass matrix are distributed over the film in a uniform manner. Active strains (according to ISO 22196) Reducing > 99.99 % of bacteria ascertained for: • Escherichia coli • Salmonella (Salmonelle enterica) • Listeria (Listeria monocytogenes) • Golden staph (Staphylococcus aureus) • Methicillin-resistant Staphylococcus aureus (MRSA) • Pseudomonas aeruginosa Antiviral activity on the Human coronavirus HCoV-229E strain (according to the ISO 21702 standard): • 94.99 % after a contact time of 15 minutes • 99.87 % after a contact time of 60 minutes Under normal usage conditions, harmless when in contact with human skin (skin compatibility study carried out under dermatological control). • No allergenic potential • No irritant potential • Active compound: silver ions, < 0.3 % w/w of the entire product • Antimicrobial activity maintained after 365 cleanings with water, alcohol, and chlorine bleach • Resistance to solvents: the adhesive is resistant to most chemicals (alcohol, diluted acids, oils). The film can be cleaned/disinfected by all conventional cleaning methods, using non-abrasive accessories, cleaning products, detergents or products currently used in healthcare environments • The disinfection levels achieved are compatible with common usage in the most sensitive areas in terms of infectious risks • Recommended minimum application temperature: +10 °C (+50 °F). • Operating temperature range: from -40 °C to +90 °C (-40 °F to +194 °F)
13
Embed
ANTI-MICROBIAL CONFORM - Graffiti Shield · THE ANTI-MICROBIAL ACTION OF SILVER IONS In its (elemental) metallic form, silver is inert and does not kill bacteria. Silver atoms (written
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ANTI-MICROBIAL CONFORMPROTECTIVE FILM
714-575-1100 www.Graffiti-Shield.com
Tested by third party to ISO testing standards against most common illness-causing bacteria and coronavirus. Antimicrobial technology is applied to the product; it does not directly protect the user from any exposure to bacteria or viruses, or provide additional health benefits. Pure Zone antimicrobial film contains an active ingredient (silver ions approved by EPA under file number 73148-1-91742). Pure Zone has been tested and proven to reduce Coronavirus by up to 99.87% (after 1 hour) and reduce up to 99.99% of bacteria (after 1 hour) such as: Listeria, Salmonella, Golden Staph, Methicillin-resistant Staphylococcus aureus, and Pseudomonas aeruginosa. It is strongly recommended to practice good hygiene, wash hands regularly, and maintain social distancing as often as possible.
During cleaning operations, as well as in the presence of humidity, silver ions are released from the top layer of the film. These ions come into contact with the bacteria, blocking their metabolism and/or interrupting their proliferation mechanism, leading to their destruction When the Anti-Microbial film is manufactured, silver ions encapsulated in a glass matrix are distributed over the film in a uniform manner.
Active strains (according to ISO 22196)Reducing > 99.99 % of bacteria ascertained for:
Antiviral activity on the Human coronavirus HCoV-229E strain (according to the ISO 21702 standard):
• 94.99 % after a contact time of 15 minutes• 99.87 % after a contact time of 60 minutes
Under normal usage conditions, harmless when in contact with human skin (skin compatibility study carried out under dermatological control). • No allergenic potential • No irritant potential
• Active compound: silver ions, < 0.3 % w/w of the entire product
• Antimicrobial activity maintained after 365 cleanings with water, alcohol, and chlorine bleach
• Resistance to solvents: the adhesive is resistant to most chemicals (alcohol, diluted acids, oils). The film can be cleaned/disinfected by all conventional cleaning methods, using non-abrasive accessories, cleaning products, detergents or products currently used in healthcare environments
• The disinfection levels achieved are compatible with common usage in the most sensitive areas in terms of infectious risks
• Recommended minimum application temperature: +10 °C (+50 °F).
• Operating temperature range: from -40 °C to +90 °C (-40 °F to +194 °F)
ANTI-MICROBIAL CONFORMPROTECTIVE FILM
714-575-1100 www.Graffiti-Shield.com
Anti-Microbial film applied in areas of frequent handling (e.g.: handles) or high visitor frequency will be subject to repeated abrasion which will reduce its durability (change of appearance, lifting, etc.). The film durability depends on the intensity and frequency of the mechanical stress to which it is exposed.
ANTI-MICROBIAL FILM FEATURES:Indicative value
• Thickness: 2.4 mil Average Values
• Tensile strength (N/25 mm): min. 15 • Elongation at break (%): min. 100• Shrinkage 168 hours at 70 °C (158 °F) (mm): < 0.6 mm
ADHESIVE PROPERTIES:(Measured average values at publication of the technical data sheet)
Average value Standard• Peel strength test 180° on glass (N/25 mm): - after 20 minutes of application 15 - after 24 hours of application 17• Initial tack (N/25 mm): 20• Release (N/25 mm): 0.5
THE ANTI-MICROBIAL ACTION OF SILVER IONS
In its (elemental) metallic form, silver is inert and does not kill bacteria. Silver atoms (written as Ag or Ag0) must lose an electron and become positively charged silver ions, Ag+. Silver is ionised in air, but above all in a humid environment. Silver ions are highly reactive and affect multiple sites in bacterial cells, guaranteeing their destruction.
SILVER IONS : • Produce alterations to the
cell wall
• When transported into the cell, bind with proteins and interfere with the production of energy, enzyme function and cell replication
• Silver ions are active on a broad spectrum of bacteria
Reference : CHL-R14-0815 Intertek France - Etablissement de Chalon/Saône CHL-R16-1301 12 rue Alfred Kastler – Boite N° 7 71530 FRAGNES www.intertek-france.com
Intertek France – Etablissement de Chalon/Saône
This report only concerns samples submitted for testing. This report must not be reproduced, if not in entirely, without the written authorization of the laboratory General Conditions of Services information available upon request. You can send your comments on this report in two months by email [email protected]
Certificate of analysis
Society : HEXIS Address : ZI Horizons sud
34110 FRONTIGNAN
To the attention of: Nathalie SIBOLD
Customer Reference: Film Antimicrobien Pure Zone Intertek Sample Reference: 14-CHL-0815-02 / 16-CHL-1301-01Date of Sample Receipt: September 1st, 2014 / November 28th, 2016Date of Sample Analysis: September 10th, 2014 / December 6th, 2016Date of the Certificate of Analysis: July 21st, 2017
Test: Evaluation of antimicrobial efficiency based on ISO 22196
Results: The results are given as log reduction R, corresponding to the value of antimicrobial activity.
Salmonella enterica subsp enterica R > 4.56 (for sample 14-CHL-0815-02) Listeria monocytogenes R > 4.21 (for sample 14-CHL-0815-02) Staphylococcus aureus R > 4.12 (for sample 14-CHL-0815-02) Escherichia coli R = 4.54 (for sample 14-CHL-0815-02) MRSA R > 3.51 (for sample 14-CHL-0815-02) Pseudomonas aeruginosa R > 5.37 (for sample 16-CHL-1301-01)
Certified by Sylvie LEBRAT Laboratory Director
R2007HEX001-1 Page 1/ 10
REPRODUCTION ET DIFFUSION INTERDITE SANS AUTORISATION
R2007HEX001-1
Antiviral activity of PUREZONE060/PRZ150/PURECOVER surface on
human coronavirus HCoV-229E for a contact time of 15 and 60min.
Adapted protocol from ISO 21702 (201) standard
CLIENT
HEXIS
Monsieur Christophe BAUDRION
Z. I. Horizons Sud
34110 FRONTIGNAN
FRANCE
PRESTATION
EFFECTUÉE PAR
S.A.S VIRHEALTH
Site Laennec-La Buire, 2éme étage, Bat B
7-11 rue Guillaume Paradin,
69372 Lyon Cedex 08
CONTRIBUTION
TECHNIQUE Léa Szpiro, responsable laboratoire
Dounia Bouchami, technicienne de laboratoire
Approbateur/Validation Qualité
Nom : Dr Vincent Moulès, CEO
Date : At Lyon, 01/07/2020
Signature :
This report includes 10 pages
R2007HEX001-1 Page 2/ 10
REPRODUCTION ET DIFFUSION INTERDITE SANS AUTORISATION
SUMMARY
I. CONCLUSION ...................................................................................................................... 3
II. CONTRACTUAL DOCUMENTS ............................................................................................... 4
III. TEST CONDITIONS AND SAMPLES DATA ............................................................................... 4 III.1 SAMPLES IDENTIFICATION ............................................................................................................... 4
III. RÉSULTS ............................................................................................................................. 6 ANTIVIRAL ACTIVITY OF THE PUREZONE060/PRZ150/PURECOVER SURFACE ON HUMAN CORONAVIRUS HCOV-
229E FOR A CONTACT TIME OF 15 AND 60 MINUTES ..................................................................................... 6
a. Cell susceptibility ............................................................................................................................. 6 a. Cytotoxicity ...................................................................................................................................... 6 a. Essai ................................................................................................................................................. 7
VI. ANNEXES ............................................................................................................................ 8 ...................................................................................................................................................................................... 8
R2007HEX001-1 Page 3/ 10
REPRODUCTION ET DIFFUSION INTERDITE SANS AUTORISATION
I. CONCLUSION
Antiviral activity of the PUREZONE060/PRZ150/PURECOVER surface and non-active surface have
been tested under conditions defined by the ISO 21702 (2019) adapted protocol for contact times of 15
and 60 minutes on the human coronavirus HCoV-229E
Stainless steel surface is the control for this test.
● PUREZONE060/PRZ150/PURECOVER surface, 15 minutes of contact time
Under experimental conditions, (20°C, 15 minutes), the PUREZONE060/PRZ150/PURECOVER
surface shows an antiviral activity associated with a logarithmic reduction of 1.30 log10 which is
equivalent to a 94.99% efficiency under the ISO 21702 adapted protocol.
● PUREZONE060/PRZ150/PURECOVER surface, 60 minutes of contact time
Under experimental conditions, (20°C, 15 minutes), the PUREZONE060/PRZ150/PURECOVER
surface shows an antiviral activity associated with a logarithmic reduction of 2.90 log10 which is
equivalent to a 99.87% efficiency under the ISO 21702 adapted protocol.