S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2174.000
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 1000.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 343.338
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 1352.720
5 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strength) of any
size and diameter including straightening , bending, placing,
binding in position
with binding wire, placing spacers. Complete in all respects as
per specification and
instruction of Engineer incharge.
M.Ton 5.438
6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 147.225
7 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 569.625
8 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1126.922
9 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 5023.969
Annex B2 Technical Specifications LOT 2
Civil Works Kohat BHU Nakaband
Page 1 of 35
-
1013-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 5023.969
11 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 540.813
12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
245.149
13 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 1435.938
14 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 105.000
15 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 4.000
16 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 151.000
17 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 111.000
18 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
19 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 144.000
20 24-17-a-01
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 26.000
21 09--05
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 1120.000
22 06-05-h
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 43.560
S.NO MRS-2017 Description Unit QuantityIE-1 15-50 Wiring of
light/fan/call-bell point in 3/0.029 PVC insulated Each 16.000
IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC
insulated 250/440 voltage
grade cable.Rft 400.000
Internal Electrification works Kohat BHU Nakaband
Page 2 of 35
-
IE-3 15-81 Supply and fixing 20 ampere power pluge Each
4.000
IE-4 15-82 Supply and fixing 30 ampere power pluge Each
8.000
IE-5 15-83 Supply and fixing 10 ampere power pluge Each
6.000
IE-6 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 4.000
IE-7 NSI
Supply & Installation of 12" sweep, plastic body, Exhaust
fan including all civil
works required for complete installation and of Asia/Climax/Pak
fan made
including all labour and materials cable as required at site and
as approved by the
Engineer Incharge. (Exaust fan will be fitted in proper steel
frame along with wire
gauze at external side)
Each 4.000
IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for
hanging ceiling fan Each 6.000
IE-9 15-61-aSupply and Erection fluorescent tube light fitting
including 4' rod, choke, starter,
flexible wire etc : SingleEach 10.000
IE-10 15-53Special Earthing of iron/metal clad switches etc with
copper wire No. 8 SWG in GI
pipe 1/2" diaEach 1.000
E-11
15-71-d Supply and Erection single phase imported auto circuit
breaker 30 Amp. Each 4.000
15-71-a Supply and Erection single phase imported auto circuit
breaker 6 Amp Each 14.000
15-71-b Supply and Erection single phase imported auto circuit
breaker 15 Amp Each 12.000
NSISupply and Erection Cubical Type Factory Fabricated
floor/wall mounting steel
main board comp. : RecessedNo 1.000
IE-9 NSIProviding and fixing of distribution board along with
best quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Labour room and recovery room)
No 2.000
NSIProviding and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Wash Room and Verandah)
No 2.000
Sub Head MRS-2017 Description Unit Quantity
Sanitary 14-01-aP/F: European type WC (ICI Boch or equivalent)
i/c flush Tanki, P/Trap, Stop Cock,
Plastic Connection etc. Complete as per specification and
instruction of Engineer
Incharge(Porta , Duur or equivalent )
Each 5.000
14-05-b-01Providing and fixing glazed earthen WHB complte with
pedistal white size 25" x 18"
Each 3.000
14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each
3.000
14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each
10.000
14-17P/F: of 22"x16"best quality 5mm mirror glass of approved
quality. Complete in all
respect as per specification and instruction of Engineer
incharge.Each 3.000
14.20 cP/F: best quality towel rail of approved quality as per
specification and instruction
of engineer inchargeEach 3.000
14.20 bP/F: best quality paper holder of approved quality as per
specification and
instruction of engineer inchargeEach 5.000
Distribution Board:
Water Supply and Sanitation Works Kohat BHU Nakaband
Page 3 of 35
-
14.20 aP/F: best quality plastic soap dish of approved quality
as per specification and
instruction of engineer inchargeEach 3.000
14-28-a Providing and Fixing gun metal peet / gate valve
(screwed) 1" dia Each 6.000
14-31-bProviding and Fixing CI floor trap including CI grating
& concrete chamber all round
: 4"x3"Each 2.000
Water supply 14-55-e Providing and Fixing GI pipe &
including specials complete 3/4" dia (light) Rft 800.000
14-55-f Providing and Fixing GI pipe & including specials
complete 1/2" dia (light) Rft 500.000
14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 2.000
Sewerage 14-70-aProviding and Fixing of pipe type B nikasi
system including testing in all respect 110
mm (using dadex, or eq)Rft 195.000
14-37-c Supply and Fixing CI manhole cover with frame etc
complete 25" dia Each 7.000
23-Oct Construction of septic tank (7' x 2' x 5') complete in
all respect) Each 2.000
23-NovConstruction of Soakage pit having 6 Rft dia and 10 Rft
deep filled with brick and
brick linning at sideEach 2.000
NSIConstruction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
Each 8.000
S No. MRS Code 2017 Description Units Nos Length
WidthHeight/Dep
th
Total
Quantities1 04-48-b Remove of extra material from roof Sft 1.000
42.000 21.000 882.000
2 10-15-e PCC (1:2:4) as screeding 2" thick Sft 1.000 42.000
21.000 882.000
3 11-09-b Cement sand mortor on walls in 1:4 CSM Sft 1.000
1480.000
4 10-15-eProvide & lay topping of concrete 1:2:4, including
surface finishing & dividing in
panels : 2" thickSft 2.000 12.000 15.000 180.000
5 10-15-eProvide & lay topping of concrete 1:2:4, including
surface finishing & dividing in
panels : 2" thickSft 2.000 11.000 12.000 132.000
6 NSIRepairing of Existing Cupboard, replaceing of damage sheets
and locks etc
complete with paint and pannelsSft 2.000 6.000 10.000
120.000
7 04-24Repairing and fixing of old wooden door in pannels with
chowkat, locks and polish
in wooden color completeSft 6.000 7.000 3.000 126.000
9 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per
sq. in, fixed to steel window
completeSft 4.000 6.000 4.000 96.000
10 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000
22.000 15.000 0.333 219.780
11 13-05-c-01 & 02Painting old surfaces : Doors / windows
any type First coat & one another coat. In
3 quarters and their boundary wallsSft 3.000 340.000 10.000
1500.000
12 14-69-a-02 P/F Fibre Glass Water Tank 400 gallons Each 1.000
1.000 1.000
13 14-03-aProviding and Fixing glazed earthen ware WC squatting
type with built-in foot rests
: WhiteNo 2.000 2.000 4.000
14 14-05-a-02 Providing and Fixing glazed earthen ware WHB
complete No 2.000 4.000 2.000
15 14-31-b Floor Trap complete with fitting No 2.000 2.000
4.000
16 23-02-a Providing and Laying non-reinforced concrete pipe RFT
2.000 80.000 160.000
Rehabilitation Works Kohat BHU Nakaband
Page 4 of 35
-
17 NSI PVC Pipe 4 inch dia Royal or Ill for the sewarage line
Each 2.000 80.000 160.000
19 11-09-b Plaster on the walls in 1:4 CSM Cft 1.000 200.000
0.750 3.000 450.000
20 14-81-aSupply and fixing of 3.0 HP Monoblock water pump
1.5"x1.5" size 5 stage DE-S5
model single phase for 220 ft head with all accessories.No 1.000
1.000 1.000
21 24-02-d-01Tubewell boring in all soils except shingle/rock
From 300'
to 400' below ground : 8" i/dNo 1.000 150.000 150.000
22 24-12-c-01Providing and installing PVC blind pipe in tubewell
with
strainer BSS Class 'D' working pressure : 6" i/dRft 1.000
-38.000 -38.000
23 24-09-c-0Providing and installing PVC strainer, in
tubewell
borehole comp. BSS Class 'D' working pressure : 6" i/dRFT 1.000
39.000 39.000
24 24-14Shrouding with graded pack grave 3/8" to 1/8" around
tubewell in bore holeCFT 1.000 60.000 60.000
25 24-30-a-01Providing and Laying HDPE pipe
Din-/Din-/ISO-4427
incl testing & disinfect complete (20mm diaRFT 1.000 160.000
160.000
26 24-16-c-02Providing and Laying cut, joint, test &
disinfect GI pipe
line Using light quality GI Pipe : 3/4" i/d RFT 1.000 90.000
90.000
1917-10-b-01 4" thick PCC lining, using washed screened
&
graded/curshed stone aggregate : On slope : Ratio 1:2:4 for wall
CFT 2.000 300.000 0.330 0.500 99.000
21 11-08-a Cement plaster 1:3 upto 20' height 3/8" thick SFT
2.000 200.000 2.500 1000.000
23 07-05-a-05 Pacca brick work in ground floor Cement, sand
mortar 1:6 CFT 1.000 200.000 0.750 2.500 375.000
2413-05-a-01+2x 13-
05-a-02
Painting old corrugated surfaces, pent roofing etc. with oil
first and subsequent
coatSft 2.000 8.000 6.000 0.000 96.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 376.000
2 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.Cft 62.000
3 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 86.760
4 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 0.350
5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat,
one layer polythene and
one coat bitumen ( 2" thick)Sft 39.550
Waiting Shed Kohat BHU Nakaband
Page 5 of 35
-
6 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 164.500
7 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 242.440
8 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 735.000
913-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 735.000
10 10-03-aProvding sand cushion in lyers as specified under
concreet, road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 160.000
11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
52.800
12 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 160.000
13 24-16-c-08 Extra for providing /fixing approved quality rim
locks : local Rft 36.000
14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft
100.000
15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24
BWG Sft 216.000
16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down
graded stone aggregate i/c form-
work, placing, compacting, leveling and curing etc. Complete as
per specification
and instructions of Engineer incharge.
Cft 34.980
17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 1.000
1815-05-e
Supply and Erection 7/.044" single core Copper PVC insulated
250/440 voltage
grade cable.Rft 75.000
19 15-81 Supply and fixing 20 ampere power pluge Each 1.000
20 15-78 Supply and Fixing bracket fan pak made complete Each
2.000
2115-61-a
Supply and Erection fluorescent tube light fitting including 4'
rod, choke, starter,
flexible wire etc : SingleEach 2.000
22 NSI Benches for Patients. No 2.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2174.000
Civil Works Kohat BHU Parshai
Page 6 of 35
-
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 1000.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 343.338
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 1352.720
5 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strength) of any
size and diameter including straightening , bending, placing,
binding in position
with binding wire, placing spacers. Complete in all respects as
per specification and
instruction of Engineer incharge.
M.Ton 5.438
6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 147.225
7 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 569.625
8 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1126.922
9 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 5023.969
1013-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 5023.969
11 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 540.813
12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
245.149
13 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 1435.938
Page 7 of 35
-
14 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 105.000
15 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 4.000
16 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 151.000
17 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 111.000
18 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
19 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 144.000
20 24-17-a-01
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 26.000
21 09--05
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 1120.000
22 06-05-h
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 43.560
S.NO MRS-2017 Description Unit Quantity
IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 16.000
IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC
insulated 250/440 voltage
grade cable.Rft 400.000
IE-3 15-81 Supply and fixing 20 ampere power pluge Each
4.000
IE-4 15-82 Supply and fixing 30 ampere power pluge Each
8.000
IE-5 15-83 Supply and fixing 10 ampere power pluge Each
6.000
IE-6 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 4.000
IE-7 NSI
Supply & Installation of 12" sweep, plastic body, Exhaust
fan including all civil
works required for complete installation and of Asia/Climax/Pak
fan made
including all labour and materials cable as required at site and
as approved by the
Engineer Incharge. (Exaust fan will be fitted in proper steel
frame along with wire
gauze at external side)
Each 4.000
Internal Electrification works Kohat BHU Parshai
Page 8 of 35
-
IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for
hanging ceiling fan Each 6.000
IE-9 15-61-aSupply and Erection fluorescent tube light fitting
including 4' rod, choke, starter,
flexible wire etc : SingleEach 14.000
IE-10 15-53Special Earthing of iron/metal clad switches etc with
copper wire No. 8 SWG in GI
pipe 1/2" diaEach 1.000
E-11
15-71-d Supply and Erection single phase imported auto circuit
breaker 30 Amp. Each 4.000
15-71-a Supply and Erection single phase imported auto circuit
breaker 6 Amp Each 14.000
15-71-b Supply and Erection single phase imported auto circuit
breaker 15 Amp Each 12.000
NSISupply and Erection Cubical Type Factory Fabricated
floor/wall mounting steel
main board comp. : RecessedNo 1.000
IE-9 NSIProviding and fixing of distribution board along with
best quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Labour room and recovery room)
No 2.000
NSIProviding and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Wash Room and Verandah)
No 2.000
Sub Head MRS-2017 Description Unit Quantity
Sanitary 14-01-a
P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki,
P/Trap, Stop Cock,
Plastic Connection etc. Complete as per specification and
instruction of Engineer
Incharge(Porta , Duur or equivalent )
Each 5.000
14-05-b-01 Providing and fixing glazed earthen WHB complte with
pedistal white size 25" x 18" Each 3.000
14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each
3.000
14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each
10.000
14-17P/F: of 22"x16"best quality 5mm mirror glass of approved
quality. Complete in all
respect as per specification and instruction of Engineer
incharge. Each 3.000
14.20 cP/F: best quality towel rail of approved quality as per
specification and instruction
of engineer incharge Each 3.000
14.20 bP/F: best quality paper holder of approved quality as per
specification and
instruction of engineer inchargeEach 5.000
14.20 aP/F: best quality plastic soap dish of approved quality
as per specification and
instruction of engineer incharge Each 3.000
14-28-a Providing and Fixing gun metal peet / gate valve
(screwed) 1" dia Each 6.000
14-31-bProviding and Fixing CI floor trap including CI grating
& concrete chamber all round
: 4"x3"Each 2.000
Water supply 14-55-e Providing and Fixing GI pipe &
including specials complete 3/4" dia (light) RFt 800.000
14-55-f Providing and Fixing GI pipe & including specials
complete 1/2" dia (light) RFt 500.000
14-69-b-03 P/F Fibre Glass Water Tank 500 gallons Each 3.000
Sewerage 14-70-aProviding and Fixing of pipe type B nikasi
system including testing in all respect 110
mm (using dadex, or eq)Rft 195.000
Distribution Board:
Water Supply and Sanitation Works Kohat BHU Parshai
Page 9 of 35
-
NSIProviding and Fixing of pipe type wind pipe system including
testing in all respect
of 2 inch with capRft 110.000
14-37-c Supply and Fixing CI manhole cover with frame etc
complete 25" dia Each 7.000
23-10 Construction of septic tank (7' x 2' x 5') complete in all
respect) Each 2.000
23-11Construction of Soakage pit having 6 Rft dia and 10 Rft
deep filled with brick and
brick linning at sideEach 2.000
NSI
Construction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
Each 8.000
S No. MRS Code 2017 Description Units Nos Length
WidthHeight/Dep
th
Total
Quantities1 04-48-b Remove of extra material from roof Sft 1.000
42.000 21.000 882.000
2 10-15-e PCC (1:2:4) as screeding 2" thick Sft 1.000 42.000
21.000 882.000
3 11-09-b Cement sand mortor on walls in 1:4 CSM Sft 1.000
1480.000
4 10-15-eProvide & lay topping of concrete 1:2:4, including
surface finishing & dividing in
panels : 2" thickSft 2.000 12.000 15.000 180.000
5 10-15-eProvide & lay topping of concrete 1:2:4, including
surface finishing & dividing in
panels : 2" thickSft 2.000 11.000 12.000 132.000
6 13-05-c-01 & 02Painting old surfaces : Doors / windows any
type First coat & one another coat. In
3 quarters and their boundary wallsSft 2.000 6.000 10.000
1200.000
7 04-24Repairing and fixing of old wooden door in pannels with
chowkat, locks and polish
in wooden color completeSft 6.000 7.000 3.000 126.000
8 NSIRepair of external MS Grill repair with welding &
replacement of broken/rusted
portions complete & prepared for paint jobSft 4.000 6.000
4.000 96.000
9 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per
sq. in, fixed to steel window
completeSft 4.000 6.000 4.000 96.000
10 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000
22.000 15.000 0.333 219.780
11 13-05-c-01 & 02Painting old surfaces : Doors / windows
any type First coat & one another coat. In
3 quarters and their boundary wallsSft 3.000 340.000 10.000
1500.000
12 14-69-a-03 P/F Fibre Glass Water Tank 500 gallons Each 1.000
1.000 1.000
13 14-03-aProviding and Fixing glazed earthen ware WC squatting
type with built-in foot rests
: WhiteNo 2.000 2.000 4.000
14 14-05-a-02 Providing and Fixing glazed earthen ware WHB
complete No 2.000 4.000 8.000
15 14-31-b Floor Trap complete with fitting No 2.000 2.000
4.000
16 23-02-a Providing and Laying non-reinforced concrete pipe Rft
2.000 80.000 160.000
17 14-81-aSupply and fixing of 3.0 HP Monoblock water pump
1.5"x1.5" size 5 stage DE-S5
model single phase for 220 ft head with all accessories.No 1.000
1.000 1.000
18 24-02-d-01Tubewell boring in all soils except shingle/rock
From 300'
to 400' below ground : 8" i/dNo 1.000 150.000 150.000
19 24-12-c-01Providing and installing PVC blind pipe in tubewell
with
strainer BSS Class 'D' working pressure : 6" i/dRft 1.000
-38.000 -38.000
Rehabilitation Works Kohat BHU Parshai
Page 10 of 35
-
20 24-09-c-0Providing and installing PVC strainer, in
tubewell
borehole comp. BSS Class 'D' working pressure : 6" i/dRft 1.000
39.000 39.000
21 24-14Shrouding with graded pack grave 3/8" to 1/8" around
tubewell in bore holeCft 1.000 60.000 60.000
22 24-30-a-01Providing and Laying HDPE pipe
Din-/Din-/ISO-4427
incl testing & disinfect complete (20mm diaRft 1.000 160.000
160.000
23 24-16-c-02Providing and Laying cut, joint, test &
disinfect GI pipe
line Using light quality GI Pipe : 3/4" i/d Rft 1.000 90.000
90.000
24 11-09-b Plaster on the walls in 1:4 CSM Cft 1.000 200.000
0.750 3.000 450.000
25 NSI
Construction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
No 8.000 8.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 376.000
2 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.Cft 62.000
3 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 86.760
4 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 0.350
5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat,
one layer polythene and
one coat bitumen ( 2" thick)Sft 39.550
6 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 164.500
7 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 242.440
Waiting Shed Kohat BHU Parshai
Page 11 of 35
-
8 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 735.000
913-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 735.000
10 10-03-aProvding sand cushion in lyers as specified under
concreet, road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 160.000
11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
52.800
12 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 160.000
13 24-16-c-08 Extra for providing /fixing approved quality rim
locks : local Rft 36.000
14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft
100.000
15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24
BWG Sft 216.000
16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down
graded stone aggregate i/c form-
work, placing, compacting, leveling and curing etc. Complete as
per specification
and instructions of Engineer incharge.
Cft 34.980
17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 1.000
1815-05-e
Supply and Erection 7/.044" single core Copper PVC insulated
250/440 voltage
grade cable.Rft 75.000
19 15-81 Supply and fixing 20 ampere power pluge Each 1.000
20 15-78 Supply and Fixing bracket fan pak made complete Each
2.000
2115-61-a
Supply and Erection fluorescent tube light fitting including 4'
rod, choke, starter,
flexible wire etc : SingleEach 2.000
22 NSI Benches for Patients. No 2.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2174.000
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 1000.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 343.338
Civil Works Kohat BHU Togh Bala
Page 12 of 35
-
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 1352.720
5 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strength) of any
size and diameter including straightening , bending, placing,
binding in position
with binding wire, placing spacers. Complete in all respects as
per specification and
instruction of Engineer incharge.
M.Ton 5.438
6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 147.225
7 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 569.625
8 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1126.922
9 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 5023.969
1013-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 5023.969
11 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 540.813
12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
245.149
13 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 1435.938
14 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 105.000
15 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 4.000
Page 13 of 35
-
16 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 151.000
17 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 111.000
18 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
19 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 144.000
20 24-17-a-01
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 26.000
21 09--05
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 1120.000
22 06-05-h
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 43.560
S.NO MRS-2017 Description Unit Quantity
IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 16.000
IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC
insulated 250/440 voltage
grade cable.Rft 400.000
IE-3 15-81 Supply and fixing 20 ampere power pluge Each
4.000
IE-4 15-82 Supply and fixing 30 ampere power pluge Each
8.000
IE-5 15-83 Supply and fixing 10 ampere power pluge Each
6.000
IE-6 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 4.000
IE-7 NSI
Supply & Installation of 12" sweep, plastic body, Exhaust
fan including all civil
works required for complete installation and of Asia/Climax/Pak
fan made
including all labour and materials cable as required at site and
as approved by the
Engineer Incharge. (Exaust fan will be fitted in proper steel
frame along with wire
gauze at external side)
Each 4.000
IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for
hanging ceiling fan Each 6.000
IE-9 15-61-aSupply and Erection fluorescent tube light fitting
including 4' rod, choke, starter,
flexible wire etc : SingleEach 10.000
Internal Electrification works Kohat BHU Togh Bala
Page 14 of 35
-
IE-10 15-53Special Earthing of iron/metal clad switches etc with
copper wire No. 8 SWG in GI
pipe 1/2" diaEach 1.000
E-11
15-71-d Supply and Erection single phase imported auto circuit
breaker 30 Amp. Each 4.000
15-71-a Supply and Erection single phase imported auto circuit
breaker 6 Amp Each 14.000
15-71-b Supply and Erection single phase imported auto circuit
breaker 15 Amp Each 12.000
NSISupply and Erection Cubical Type Factory Fabricated
floor/wall mounting steel
main board comp. : RecessedNo 1.000
IE-9 NSIProviding and fixing of distribution board along with
best quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Labour room and recovery room)
No 2.000
NSIProviding and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Wash Room and Verandah)
No 2.000
Sub Head MRS-2017 Description Unit Quantity
Sanitary 14-01-a
P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki,
P/Trap, Stop Cock,
Plastic Connection etc. Complete as per specification and
instruction of Engineer
Incharge(Porta , Duur or equivalent )
Each 5.000
14-05-b-01 Providing and fixing glazed earthen WHB complte with
pedistal white size 25" x 18" Each 3.000
14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each
3.000
14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each
10.000
14-17P/F: of 22"x16"best quality 5mm mirror glass of approved
quality. Complete in all
respect as per specification and instruction of Engineer
incharge. Each 3.000
14.20 cP/F: best quality towel rail of approved quality as per
specification and instruction
of engineer incharge Each 3.000
14.20 bP/F: best quality paper holder of approved quality as per
specification and
instruction of engineer inchargeEach 5.000
14.20 aP/F: best quality plastic soap dish of approved quality
as per specification and
instruction of engineer incharge Each 3.000
14-28-a Providing and Fixing gun metal peet / gate valve
(screwed) 1" dia Each 6.000
14-31-bProviding and Fixing CI floor trap including CI grating
& concrete chamber all round
: 4"x3"Each 2.000
Water supply 14-55-e Providing and Fixing GI pipe &
including specials complete 3/4" dia (light) RFt 800.000
14-55-f Providing and Fixing GI pipe & including specials
complete 1/2" dia (light) RFt 500.000
14-69-b-03 P/F Fibre Glass Water Tank 500 gallons Each 3.000
Sewerage 14-70-aProviding and Fixing of pipe type B nikasi
system including testing in all respect 110
mm (using dadex, or eq)Rft 195.000
NSIProviding and Fixing of pipe type wind pipe system including
testing in all respect
of 2 inch with capRft 110.000
14-37-c Supply and Fixing CI manhole cover with frame etc
complete 25" dia Each 7.000
Distribution Board:
Water Supply and Sanitation Works Kohat BHU Togh Bala
Page 15 of 35
-
23-10 Construction of septic tank (7' x 2' x 5') complete in all
respect) Each 2.000
23-11Construction of Soakage pit having 6 Rft dia and 10 Rft
deep filled with brick and
brick linning at sideEach 2.000
NSI
Construction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
Each 8.000
S No. MRS Code 2017 Description Units Nos Length
WidthHeight/Dep
th
Total
Quantities
1 13-05-c-01 & 02Painting old surfaces : Doors / windows any
type First coat & one another coat. In
3 quarters and their boundary wallsSft 1.000 1800.000
2 12-51Provide & fix GI wire gauze 22 SWG, 12x12 mesh per
sq. in, fixed to steel window
completeSft 4.000 6.000 4.000 96.000
3 06-05-f PCC 1:2:4 in the open space of the BHU Cft 2.000
22.000 15.000 0.333 219.780
4 15-02-a-06Supply and Erection PVC pipe for wiring purpose
complete On surface including
clamps etc: 2" i/dRft 2.000 250.000 500.000
5 15-05-aSupply and Erection single core PVC insulated copper
conductor 3/29 V grade
cableRft 2.000 500.000 1000.000
6 15-05-fSupply and Erection single core PVC insulated copper
conductor 250/440 V grade
cable : 7/0.064"Rft 2.000 100.000 200.000
7 15-18-a Supply and Erection switches 10/15 Amp : Open type
Each 2.000 4.000 8.000
8 15-80 Supply and Fixing dimmer switch complete Each 2.000
3.000 6.000
9 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 4.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 376.000
2 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.Cft 62.000
3 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 86.760
4 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 0.350
Rehabilitation Works Kohat BHU Togh Bala
Waiting Shed Kohat BHU Togh Bala
Page 16 of 35
-
5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat,
one layer polythene and
one coat bitumen ( 2" thick)Sft 39.550
6 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 164.500
7 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 242.440
8 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 735.000
913-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 735.000
10 10-03-aProvding sand cushion in lyers as specified under
concreet, road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 160.000
11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
52.800
12 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 160.000
13 24-16-c-08 Extra for providing /fixing approved quality rim
locks : local Rft 36.000
14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft
100.000
15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24
BWG Sft 216.000
16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down
graded stone aggregate i/c form-
work, placing, compacting, leveling and curing etc. Complete as
per specification
and instructions of Engineer incharge.
Cft 34.980
17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 1.000
1815-05-e
Supply and Erection 7/.044" single core Copper PVC insulated
250/440 voltage
grade cable.Rft 75.000
19 15-81 Supply and fixing 20 ampere power pluge Each 1.000
20 15-78 Supply and Fixing bracket fan pak made complete Each
2.000
2115-61-a
Supply and Erection fluorescent tube light fitting including 4'
rod, choke, starter,
flexible wire etc : SingleEach 2.000
22 NSI Benches for Patients. No 2.000
Civil Works Kohat BHU Bazid Khel
Page 17 of 35
-
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2174.000
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 1000.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 343.338
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
icharge.
Cft 1352.720
06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 5.438
5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 147.225
6 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 569.625
7 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1126.922
8 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 5023.969
9 13-30-a + 2 x 13-30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 5023.969
10 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 540.813
11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
245.149
Page 18 of 35
-
12 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 1435.938
13 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 105.000
14 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 4.000
15 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 151.000
16 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 111.000
17 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
18 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 144.000
19 24-17-a-01
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 26.000
20 09--05
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 1120.000
21 06-05-h
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 43.560
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2117.000
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 882.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 259.875
Civil Works Kohat BHU Bazid Khel (New Building)
Page 19 of 35
-
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
icharge.
Cft 1225.190
5 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 4.925
6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 217.954
7 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 1625.438
8 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1220.016
9 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 6880.641
10 13-30-a + 2 x 13-30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 6880.641
11 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 790.500
12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
260.865
13 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 961.063
14 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 147.000
15 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 6.000
Page 20 of 35
-
16 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 169.000
17 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 80.000
18 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
19 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 216.000
20 24-17
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 78.000
21 09---5
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 882.000
22 06-05---H
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 122.000
S. NO MRS-2017 Description Unit Quantity
IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 32.000
IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC
insulated 250/440 voltage
grade cable.Rft 850.000
IE-3 15-81 Supply and fixing 20 ampere power pluge Each
8.000
IE-4 15-82 Supply and fixing 30 ampere power pluge Each
16.000
IE-5 15-83 Supply and fixing 10 ampere power pluge Each
12.000
IE-6 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 10.000
IE-7 NSI
Supply & Installation of 12" sweep, plastic body, Exhaust
fan including all civil
works required for complete installation and of Asia/Climax/Pak
fan made
including all labour and materials cable as required at site and
as approved by the
Engineer Incharge. (Exaust fan will be fitted in proper steel
frame along with wire
gauze at external side)
Each 12.000
IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for
hanging ceiling fan Each 12.000
IE-9 15-61-aSupply and Erection fluorescent tube light fitting
including 4' rod, choke, starter,
flexible wire etc : SingleEach 28.000
Internal Electrification works Kohat BHU Bazid Khel
Page 21 of 35
-
IE-10 15-53Special Earthing of iron/metal clad switches etc with
copper wire No. 8 SWG in GI
pipe 1/2" diaEach 2.000
E-11 Distribution Board:
15-71-d Supply and Erection single phase imported auto circuit
breaker 30 Amp. Each 8.000
15-71-a Supply and Erection single phase imported auto circuit
breaker 6 Amp Each 28.000
15-71-b Supply and Erection single phase imported auto circuit
breaker 15 Amp Each 24.000
NSISupply and Erection Cubical Type Factory Fabricated
floor/wall mounting steel
main board comp. : RecessedNo 2.000
IE-9 NSI
Providing and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Labour room and recovery room)
No 4.000
NSI
Providing and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Wash Room and Verandah)
No 4.000
Sub Head MRS-2017 Description Unit Quantity
Sanitary
14-01-a
P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki,
P/Trap, Stop Cock,
Plastic Connection etc. Complete as per specification and
instruction of Engineer
Incharge(Porta , Duur or equivalent )
Each 5.000
14-05-b-01Providing and fixing glazed earthen WHB complte with
pedistal white size 25" x 18"
Each 3.000
14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each
3.000
14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each
10.000
14-17P/F: of 22"x16"best quality 5mm mirror glass of approved
quality. Complete in all
respect as per specification and instruction of Engineer
incharge. Each 3.000
14.20 cP/F: best quality towel rail of approved quality as per
specification and instruction
of engineer incharge Each 3.000
14.20 bP/F: best quality paper holder of approved quality as per
specification and
instruction of engineer inchargeEach 5.000
14.20 aP/F: best quality plastic soap dish of approved quality
as per specification and
instruction of engineer incharge Each 3.000
14-28-a Providing and Fixing gun metal peet / gate valve
(screwed) 1" dia Each 6.000
14-31-bProviding and Fixing CI floor trap including CI grating
& concrete chamber all round
: 4"x3"Each 2.000
Water supply 14-55-e Providing and Fixing GI pipe &
including specials complete 3/4" dia (light) RFt 890.000
14-55-f Providing and Fixing GI pipe & including specials
complete 1/2" dia (light) RFt 500.000
14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 3.000
Sewerage14-70-a
Providing and Fixing of pipe type B nikasi system including
testing in all respect 110
mm (using dadex, or eq)Rft 225.000
NSIProviding and Fixing of pipe type wind pipe system including
testing in all respect
of 2 inch with capRft 110.000
14-37-c Supply and Fixing CI manhole cover with frame etc
complete 25" dia Each 7.000
Water Supply and Sanitation Works Kohat BHU Bazid Khel
Page 22 of 35
-
23-10 Construction of septic tank (7' x 2' x 5') complete in all
respect) Each 2.000
23-11Construction of Soakage pit having 6 Rft dia and 10 Rft
deep filled with brick and
brick linning at sideEach 2.000
NSI
Construction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
Each 8.000
S No. MRS Code 2017 Description Units Nos Length
WidthHeight/Dep
th
Total
Quantities
117-10-b-01 4" thick PCC lining, using washed screened &
graded/curshed stone aggregate : On slope : Ratio 1:2:4 for wall
Cft 2.000 300.000 0.330 0.500 99.000
2 11-08-a Cement plaster 1:3 upto 20' height 3/8" thick Sft
2.000 250.000 2.500 1250.000
3 07-05-a-05 Pacca brick work in ground floor Cement, sand
mortar 1:6 Cft 1.000 250.000 0.750 2.500 468.750
413-05-a-01+2x 13-
05-a-02
Painting old corrugated surfaces, pent roofing etc. with oil
first and subsequent
coatSft 2.000 8.000 6.000 0.000 96.000
3 14-81-aSupply and fixing of 3.0 HP Monoblock water pump
1.5"x1.5" size 5 stage DE-S5
model single phase for 220 ft head with all accessories.No 1.000
1.000 1.000
4 24-02-d-01Tubewell boring in all soils except shingle/rock
From 300'
to 400' below ground : 8" i/dNo 1.000 150.000 150.000
5 24-12-c-01Providing and installing PVC blind pipe in tubewell
with
strainer BSS Class 'D' working pressure : 6" i/dRft 1.000
-38.000 -38.000
6 24-09-c-0Providing and installing PVC strainer, in
tubewell
borehole comp. BSS Class 'D' working pressure : 6" i/dRft 1.000
39.000 39.000
7 24-14Shrouding with graded pack grave 3/8" to 1/8" around
tubewell in bore holeCft 1.000 60.000 60.000
8 24-30-a-01Providing and Laying HDPE pipe
Din-/Din-/ISO-4427
incl testing & disinfect complete (20mm diaRft 1.000 160.000
160.000
9 24-16-c-02Providing and Laying cut, joint, test &
disinfect GI pipe
line Using light quality GI Pipe : 3/4" i/d Rft 1.000 90.000
90.000
12 14-69-a-03 P/F Fibre Glass Water Tank 500 gallons Each 1.000
1.000 1.000
13 14-03-aProviding and Fixing glazed earthen ware WC squatting
type with built-in foot rests
: WhiteNo 2.000 2.000 4.000
14 14-05-a-02 Providing and Fixing glazed earthen ware WHB
complete No 2.000 4.000 2.000
15 14-31-b Floor Trap complete with fitting No 2.000 2.000
4.000
17 23-02-a Providing and Laying non-reinforced concrete pipe Rft
2.000 80.000 160.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 376.000
Waiting Shed Kohat BHU Bazid Khel
Rehabilitation Works Kohat BHU Bazid Khel
Page 23 of 35
-
2 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.Cft 62.000
3 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
incharge.
Cft 86.760
4 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 0.350
5 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat,
one layer polythene and
one coat bitumen ( 2" thick)Sft 39.550
6 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 164.500
7 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 242.440
8 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 735.000
913-30-a + 2 x 13-
30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 735.000
10 10-03-aProvding sand cushion in lyers as specified under
concreet, road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 160.000
11 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
52.800
12 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 160.000
13 24-16-c-08 Extra for providing /fixing approved quality rim
locks : local Rft 36.000
Page 24 of 35
-
14 NSI P/L, cut, joint, test and disinfect MS pipe 1.5" X 2" Rft
100.000
15 9--13--C S/F corrugated GI sheet with GI bolt,nuts,limpite 24
BWG Sft 216.000
16 06-05-hP/L: P.C.C 1:3:6 in plint protection using 3/4 down
graded stone aggregate i/c form-
work, placing, compacting, leveling and curing etc. Complete as
per specification
and instructions of Engineer incharge.
Cft 34.980
17 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 1.000
1815-05-e
Supply and Erection 7/.044" single core Copper PVC insulated
250/440 voltage
grade cable.Rft 75.000
19 15-81 Supply and fixing 20 ampere power pluge Each 1.000
20 15-78 Supply and Fixing bracket fan pak made complete Each
2.000
2115-61-a
Supply and Erection fluorescent tube light fitting including 4'
rod, choke, starter,
flexible wire etc : SingleEach 2.000
22 NSI Benches for Patients. No 2.000
S.NO MRS-2017 Description Unit Quantity
1 03-23-b Excavation in foundation of building, bridges etc
complete in ordinary soil Cft 2117.000
2 26-15 Spraying anti-termite liquid mixed with water in ration
of 1:40 Sft 882.000
3 06-05-i
P/L: P.C.C 1:4:8 in any part of building such as foundation,
etc. using 1½" down
graded stone aggregate i/c form-work, placing, compacting,
leveling and curing
etc. Complete as per specification and instructions of Engineer
incharge.
Cft 259.875
4 06-06-a-03
P/L: RCC 1:2:4 i/c using approved quality of crushed stones and
fine agregate
(sand) in roof slab, landing, wall, plienth beam & bands
including mixing in
concrete mixer, lifting, placing in steel fom work, vibrating,
consolidating, dressing,
levling and curing excluding the cost of re-inforcement bars and
the cost of laborty
quality test. Complete in all respect as per specification and
instruction of Engineer
icharge.
Cft 1225.190
5 06-07-c
PF in position mild reinforcement defomed bars (40000 psi yield
strenght) of any
size and dimetter including straightening , bending, placeing,
binding in position
with binding wire, placing spacesers. Complete in all respects
as per specification
and instruction of Engineer incharge.
M.Ton 4.925
6 06-22-a-02DPC of cement concrete 1:2:4 including bitumen coat
, one layer polythene and
one coat bitumen ( 2" thick)Sft 217.954
7 07-04-a-03
P/L: 1st class approved solid BB masonry in walls over 115mm
thicks, laid and
jointed in CM 1:4, straight or to corve with inner radious of 6m
and over, upto
4.25m depth, including racking out the joints where necessary
scaffolding & curing
etc. Complete in all respect as per specification and
instruction if Engineer
incharge.
Cft 1625.438
Civil Works Kohat RHC Gumbat
Page 25 of 35
-
8 07-05-a-03
P/L: 1st class approved solid BB masonry in walls 115mm thicks,
laid and jointed in
CM 1:4, straight or to curve with inner radious of 6m and over,
upto 4.25m depth,
including racking out the joints where necessary scaffolding
& curing etc. Complete
in all respect as per specification and instruction if Engineer
incharge.
Cft 1220.016
9 11-09-b
P/A: 1/2" thick plaster (13mm thick) on wall in 1:4 cement/sand
mortar includind
scafolding, chambering of edges, rounding the corners , making
groves and edges
where required. P/F: of expanded metal Jali 1/2"x 1/2" size, 12"
wide at all joints
of R.C.C and brick work, curing, cleaning, complete in all
respect, specifications and
instructions of engineer incharge.
Sft 6880.641
10 13-30-a + 2 x 13-30-b
Surface prepartion (for dempenss) by provission of film with
Alkali resisting primer
on plaster wall and ceilling . Including first coat of painting
new or old work such
as walls including all detacheched attachement with plast
emulsion paint.
Including subsequent tywo coats of emulsion paints.
Sft 6880.641
11 10-03-a
Provding sand cushion in lyers as specified under concreet,
road, hard standing and
landing including dressing, leveling, compacting and
consolidating as per
specification and instruction of the Engineer Inchage.
Cft 790.500
12 06-05-i Provding and laying PCC 1: 4: 8: laid under floor Cft
260.865
13 10-48-aProvding and laying porceline tile floor 1/4 inch
thick laid cement 1:2 or 3/4 inch
thick cement mortar 1:2 (local master tiles)Sft 961.063
14 12-07-aFirst class doadar wood wrought joinery in doors and
window etc complete : 2 inch
thickSft 147.000
15 12-20-a-02 Extra for providing /fixing approved quality rim
locks : local Nos 6.000
16 12-56-a
Supply and fixing MS sheet 16 gauge (10 x 2 inches)box type
chowkat including
fixing and position with all charges for hold fast hinges and
paint etc complete in
all respect as per drawings and as per specification as directed
by engineer
incharge
Rft 169.000
17 25-39-b-03
Providing and fixing steel window 18 gauge with openable glazed
panels with 22
SWG wire gauze glass pane 3 mm including grill complete in all
respect as per
drawings and specification and as per directed by the engineer
incharge
Sft 80.000
18 12-49Curtain railing to doors and windows comprising
toso-elite japanees railing or
equivalent inclunding paintRft 18.000
19 NSI Provision and fixing of blind to windows as per direction
of engineer incharge Sft 216.000
20 24-17
Supply and fixing of aproved AC building pipe Class , 80mm with
pigot and socket
joints and hexagonal head for rain water including jointing and
suport MS Plate
19mm x 6mm @ 1m apart. Complet in all respect and in accordance
with
specification and instruction of the Engineer Incharge.
Rft 78.000
Page 26 of 35
-
21 09---5
Supply and fixing of one lyer of brick tile (300mm x 150mm) x
50mm flat brick on
roof, bedded, joint and pointed in CM 1: 3: over 4" (avrage),
one coat of hot
bitumen (10 - 15 grade) and one lyer of approve polythene sheet.
Complet in all
respect and in accordance with specification and instruction of
the Engineer
Incharge.
Sft 882.000
22 06-05---H
P/L: P.C.C 1:3:6 in plint protection using 3/4 down graded stone
aggregate i/c
form-work, placing, compacting, leveling and curing etc.
Complete as per
specification and instructions of Engineer incharge.
Cft 122.000
S.NO MRS-2017 Description Unit Quantity
IE-1 15-50 Wiring of light/fan/call-bell point in 3/0.029 PVC
insulated Each 16.000
IE-2 15-05-eSupply and Erection 7/.044" single core Copper PVC
insulated 250/440 voltage
grade cable.Rft 400.000
IE-3 15-81 Supply and fixing 20 ampere power pluge Each
4.000
IE-4 15-82 Supply and fixing 30 ampere power pluge Each
8.000
IE-5 15-83 Supply and fixing 10 ampere power pluge Each
6.000
IE-6 15-68-cSupply and Erection best quality AC ceiling fan
completewith GI rod, canopy,
blades & regulator : 56" sweepEach 4.000
IE-7 NSI
Supply & Installation of 12" sweep, plastic body, Exhaust
fan including all civil
works required for complete installation and of Asia/Climax/Pak
fan made
including all labour and materials cable as required at site and
as approved by the
Engineer Incharge. (Exaust fan will be fitted in proper steel
frame along with wire
gauze at external side)
Each 4.000
IE-8 15-25 Supply and Erection girder clamp hook, 5/8" dia.for
hanging ceiling fan Each 6.000
IE-9 15-61-aSupply and Erection fluorescent tube light fitting
including 4' rod, choke, starter,
flexible wire etc : SingleEach 10.000
IE-10 15-53Special Earthing of iron/metal clad switches etc with
copper wire No. 8 SWG in GI
pipe 1/2" diaEach 1.000
E-11
15-71-d Supply and Erection single phase imported auto circuit
breaker 30 Amp. Each 4.000
15-71-a Supply and Erection single phase imported auto circuit
breaker 6 Amp Each 14.000
15-71-b Supply and Erection single phase imported auto circuit
breaker 15 Amp Each 12.000
NSISupply and Erection Cubical Type Factory Fabricated
floor/wall mounting steel
main board comp. : RecessedNo 1.000
IE-9 NSI
Providing and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Labour room and recovery room)No 2.000
Internal Electrification works Kohat RHC Gumbat
Distribution Board:
Page 27 of 35
-
NSI
Providing and fixing of distribution board along with best
quality electric button
and dimmer complete with all accesoories as recommended by the
Engineer
Incharge (Wash Room and Verandah)No 2.000
Sub Head MRS-2017 Description Unit Quantity
Sanitary 14-01-a
P/F: European type WC (ICI Boch or equivalent) i/c flush Tanki,
P/Trap, Stop Cock,
Plastic Connection etc. Complete as per specification and
instruction of Engineer
Incharge(Porta , Duur or equivalent )
Each 5.000
14-05-b-01 Providing and fixing glazed earthen WHB complte with
pedistal white size 25" x 18" Each 3.000
14-27 Providing and fixing CP mixing valve for WHB/SHOWER Each
3.000
14-24-b Providing and Fixing CP bib-cock, heavy type : 1/2" Each
10.000
14-17P/F: of 22"x16"best quality 5mm mirror glass of approved
quality. Complete in all
respect as per specification and instruction of Engineer
incharge. Each 3.000
14.20 cP/F: best quality towel rail of approved quality as per
specification and instruction
of engineer incharge Each 3.000
14.20 bP/F: best quality paper holder of approved quality as per
specification and
instruction of engineer inchargeEach 5.000
14.20 aP/F: best quality plastic soap dish of approved quality
as per specification and
instruction of engineer incharge Each 3.000
14-28-a Providing and Fixing gun metal peet / gate valve
(screwed) 1" dia Each 6.000
14-31-bProviding and Fixing CI floor trap including CI grating
& concrete chamber all round
: 4"x3"Each 2.000
Water supply 14-55-e Providing and Fixing GI pipe &
including specials complete 3/4" dia (light) RFt 800.000
14-55-f Providing and Fixing GI pipe & including specials
complete 1/2" dia (light) RFt 500.000
14-69-b-03 P/F Fibre Glass Water Tank 400 gallons Each 3.000
Sewerage 14-70-aProviding and Fixing of pipe type B nikasi
system including testing in all respect 110
mm (using dadex, or eq)Rft 195.000
NSIProviding and Fixing of pipe type wind pipe system including
testing in all respect
of 2 inch with capRft 110.000
14-37-c Supply and Fixing CI manhole cover with frame etc
complete 25" dia Each 7.000
23-10 Septic Tank (int.Size: 7'x2'x5') complete Each 1.000
23-11Construction of Soakage pit having 6 Rft dia and 15 Rft
deep filled with brick and
brick linning at sideEach 1.000
NSI
Construction of manholes 2'X2' in size including excavation,
backfilling, 9" thick
brick walls, 3" PCC 1:4:8,2" PCC 1:2:4 benching, 1/2" thick
cement sand plaster
complete.
Each 8.000
Sub Head MRS-2017 Description Unit Quantity
Water Supply and Sanitation Works Kohat RHC Gumbat
2 Unit Typical Toilet Blocks Kohat RHC Gumbat
Page 28 of 35
-
Foundation 03-23-d Excavation in foundation of building, bridges
etc complete : in shingle/gravel Cft 145.000
26-15 Spraying anti-termite liquid mixed with water in the ratio
of 1:40 Sft 220.500
03-60-c Structural backfill using Common Material available at
Cft 68.910
06-05-fPlain Cemen