Annex 3 Soil Erosion Control Plan
Overall Arrangement for Soil Erosion Control
The overall erosion control measures shall be determined for
each protection zone according to the principles of the arrangement
of erosion control. The overall layout of erosion control measures
for the full line is shown in Table 1.
Table 1 Overall Layout of Soil Erosion Control Measures along
the New Rapid Railway from Zhangjiakou to Hohhot
Control zones
Control objects
Conservation and prevention measures
Hilly area
Subgrade works
Subgrade slope
Retaining wall shall be located by using frame bolt and shaller
to protect the deep cutting. Frame slope protection and vegetation
measures shall be combined to protect subgrade slope, with
vegetation measures mainly being slope shrubs, planting shrubs and
grasses within the frame, etc.; and engineering measures are frame
slope protection with water cut-off and drainage channels, mortar
rubble slope protection and subgrade drainage works, etc.
Both sides of subgrade
Mainly plant-based measures, with shrubs inside and trees
outside, and natural recovery of both sides of the subgrade shall
be paid attention to.
Subgrade stripped topsoil
Temporary protective measures shall be taken on the temporary
stockpiling field of the stripped topsoil in the subgrade.
Station
Station
Engineering measures are mainly station slope protection and
drainage works; plant measures are landscaping design combining
trees, shrubs, flowers and grass to beautify the environment and
improve soil and water conservation.
Stripped topsoil in the station
Temporary protective measures shall be taken on the temporary
stockpiling field of stripped topsoil in the station site.
Bridge and culvert works
Bridge and culvert
Mortar rubble slope shall be used for the bridge cone slope and
river bank; cofferdam shall be set up and removed, and temporary
protective measures shall be strengthened.
Tunnel
Tunnel
Mortar rubble masonry shall be used for the side invert slope
and gutter in the tunnel entrance, and water cut-off and drainage
measures shall be taken.
Earth-fetching field
Earth-fetching field
When the construction is completed, protection measures to
spread grass seed and plant shrubs shall be taken, and temporary
protective measures shall be strengthened for the stripped topsoil
on the earth-fetching field.
Spoil (ballast) field
Spoil (ballast) field
Engineering measures and plant measures shall be combined.
Retaining walls and drains shall be installed, and topsoil cover
measures shall be taken; grass seed shall be spread or shrubs be
planted for natural recovery of spoil (ballast) body; and temporary
protective measures shall be enhanced for spoil, and stripped
topsoil in the disposable ballast.
Construction sidewalk
Construction sidewalk
It shall be remained for local use or maintenance of roads
according to the actual situation. The sidewalk which is not used
shall be cleaned up and leveled when the construction is finished,
and grass seeds shall be spread for natural recovery.
Production and living area in construction
Construction site, camp
After the construction, the garbage site and hardening space
shall be cleaned, and the surface shall be leveled; plant recovery
measures shall be taken according to the actual situation.
Plain area
Subgrade works
Subgrade slope
Frame slope protection and plant measures shall be combined for
the slope protection of the subgrade, with plant measures being
shrubs planted at the slope, shrubs planted in the frame and
seeding grass, etc. and engineering measures being frame slope
protection with water cut-off and drainage channels, mortar rubble
slope protection and subgrade drainage works.
Both sides of subgrade
Mainly plant-based measures, with shrubs inside and trees
outside, and natural recovery of both sides of the subgrade shall
be paid attention to.
Subgrade stripped topsoil
Temporary protective measures shall be taken on the temporary
stockpiling field of the stripped topsoil in the subgrade.
Station
Station
Engineering measures are mainly station slope protection and
drainage works; plant measures are landscaping design combining
trees, shrubs, flowers and grass to beautify the environment and
improve soil and water conservation.
Stripped topsoil in the station
Temporary protective measures shall be taken on the temporary
stockpiling field of stripped topsoil in the station site.
Bridge and culvert works
Bridge and culvert
Mortar rubble slope shall be used for the bridge cone slope and
river bank; cofferdam shall be set up and removed, and temporary
protective measures shall be strengthened.
Tunnel
Tunnel
Mortar rubble masonry shall be used for the side invert slope
and gutter in the tunnel entrance, and water cut-off and drainage
measures shall be taken.
Earth-fetching field
Earth-fetching field
When the construction is completed, protection measures to
spread grass seed and plant shrubs shall be taken, and temporary
protective measures shall be strengthened for the stripped topsoil
on the earth-fetching field.
Spoil (ballast) field
Spoil (ballast) field
Engineering measures and plant measures shall be combined.
Retaining walls and drains shall be installed, and topsoil cover
measures shall be taken; grass seed shall be spread or shrubs be
planted for natural recovery of spoil (ballast) body; and temporary
protective measures shall be enhanced for spoil, and stripped
topsoil in the disposable ballast.
Construction sidewalk
Construction sidewalk
It shall be remained for local use or maintenance of roads
according to the actual situation. The sidewalk which is not used
shall be cleaned up and leveled when the construction is finished,
and grass seeds shall be spread for natural recovery.
Production and living area in construction
Production and living area in construction
After the construction, the garbage site and hardening space
shall be cleaned, and the surface shall be leveled; plant recovery
measures shall be taken according to the actual situation.
Frame slope protection and plant measures shall be combined for
the slope protection of the subgrade, with plant measures being
shrubs planted at the slope, shrubs planted in the frame and
seeding grass, etc. and engineering measures being frame slope
protection with water cut-off and drainage channels, mortar rubble
slope protection and subgrade drainage works.
Subgrade Protection Measures2.1 Subgrade Protection
To reduce soil erosion resulted from subgrade filling and
excavation and to ensure the safety of the subgrade project, the
line of subgrade has been reinforced and appropriate measures such
as retaining wall protection, slope protection by framework or
mortar rubble revetment, arched or square slope, planted tank, and
new soil grass have been take based on the characteristics of
subgrade in different segments. In addition, appropriate drainage
system has been designed.
(1) General subgrade slope protection
If the height of the subgrade slope <3.0m, hollow bricks with
new soil grass and planted shrubs shall be used; if the height of
the slope≥ 3.0m, a layer of two-way geogrid with a limit tensile
strength of not less than 25.0kN/m shall be laid every a filling of
0.6m within the width of 3.0m at the outer section of the slope,
C25 concrete hollow brick with new soil grass + planted shrubs in
water disconnection framework shall be used for slope protection.
The main frame shall be 0.6m thick, and C25 concrete masonry shall
be used for the water disconnection tank. The interface between the
subgrade surface drainage and slope drainage shall be paid
attention to. Three-dimensional ecological bags may be considered
for the protection of city road segments, scenic areas and
ecologically sensitive areas. If the slope of the subgrade height
is greater than 8.0m, a different slope rate shall be taken
according to the filling height. It is 1:1.5 for the slope of 0 ~
8.0m, 1:1.75 for the slope of 8.0 ~ 12.0m, and 1:2.0 for the slope
below 12 m; and a 2.0m wide platform will be located at 12.0m for
the slope. New soil grass and planted shrubs in the hollow bricks
in C25 concrete arch water disconnection frame will be used for the
slope of 0 ~ 12.0m under the shaller, and dry stone revetment or
prefabricated solid block revetment will be used for the side slope
below 12.0m.
(2) High subgrade slope protection
If the slope height exceeds 12m, the slope rate is 1:1.5 for 0 ~
8.0m, 1:1.75 for 8.0 ~12.0m, 1:2.0 for the height below 12 m. A
2.0m-wide platform will be located at 12.0m for the slope. New soil
grass and planted shrubs in the hollow bricks in C25 concrete arch
water disconnection frame will be used for the slope of 0 ~ 12.0m
under the shaller, and dry stone revetment or prefabricated solid
block revetment will be used for the side slope below 12.0m. C25
concrete or rubble foot wall of concrete will be positioned at the
slope. Gravity retaining wall may be located at some high-fill
subgrades with less arable land to reduce the use of farmland.
(3) General graben slope protection
1) For the cutting slope of general clay and all-weathered
layer, if the height of the slope is less than 3.0m, hollow bricks
with new soil grass and planted shrubs shall be used for
protection; if the height is equal to or greater than 3.0m, hollow
bricks with new soil grass and planted shrubs in C25 concrete water
disconnection frame shall be used for protection.
2) For gravel soil, sandy soil cutting slope, hollow bricks with
new soil grass and planted shrubs in C25 concrete arched or square
grass window shall be used for protection.
3) For strong-weak weathered soft rock cutting slope whose
height is less than 8.0m, hollow bricks with new soil grass and
planted shrubs in C25 concrete water disconnection frame shall be
used for protection; if the height is greater than 8.0m, hollow
bricks with new soil grass and planted shrubs in C25 concrete arch
or square grass window shall be used for the lower side slope for
protection, hollow bricks with new soil grass and planted shrubs in
C25 concrete water disconnection frame shall be used for the most
upper side slope for protection.
4) For strong-weak weathered hard rock cutting slope, if the
slope height is less than 8.0m, hollow bricks with new soil grass
and planted shrubs in C25 concrete arch or square grass window
shall be used for protection; if the height is greater than 8.0m,
hollow bricks with new soil grass and planted shrubs in the
retaining wall of C25 concrete hollow window shall be used at the
bottom, while hollow bricks with new soil grass + planted shrubs in
C25 concrete arched or square grass window shall be used at the
upper slope for protection.
Weakly- sligthly hard rock cutting: in general, the height of
the slope is controlled within 30.0m, and M10 mortar rubbles will
be embedded for the slope. Hollow bricks with new soil grass will
be used for the protection in the concrete grass window or anchor
rod and cable within the framework.
5) In the lots with absence of A, B group packing, if the
cutting soil is sand gravel, hard rock, large platform shall be
reserved for the foot and side slope of cutting slope, with one
level every 8.0 ~ 10.0m, and the slope rate shall be reduced
accordingly. C25 concrete grass window shall be used for the slope
protection.
6) The types of water disconnection frame slope protection are
arch, herringbone and box types. They shall be used based on the
soil quality of the slope and the requirement for erosion
prevention combined with landscape demand. The spacing between the
main frame and the arch shall be 3.0m. For the general soil and
soft rock cutting, the main frame is 0.65m thick, and the
supporting frame is 0.4m thick; for very soft rock, red clay,
swelling (rock) soil cutting, the main frame is 0.8m thick, and the
supporting frame is 0.6m thick.
7) Planting tanks in which japanesecreepers and evergreen low
shrubs are planted shall be located at the platform of the side
trenches in the cutting where retaining wall, pile wall and
protection wall are located and the platform from the flooding
closed slope lot to the drainage.
(4) Deep cutting slope protection
If the height of soil and soft rock cutting slope exceeds 12.0m,
and of hard rock slope exceeds 20.0m, the deep cutting shall be
designed, and reinforced protection works shall be set.
1) Gravity retaining wall shall be used in the close of the
slope for soil and completely weathered rock cutting, and the
height of the retaining wall shall not exceed 4.0m. The measures of
slope protection refer to slope subgrade. If the slope height is
greater than 15.0m, stratified excavation shall be considered for
hierarchical reinforcement or pre- strengthening of the lowest part
of the slope.
2) In the lots where the slope height of soft rock cutting and
hard weathered rock cutting is not more than 18.0m and there is no
adverse impact on the structure surface, retaining wall, concrete
window grass slope and framework anchored rod shall be used for
protection. The height of the retaining wall shall not be greater
than 6.0m. In the lots where the slope height is greater than 18.0m
or there is adverse impact of the structure surface or broken
lithology, stratified excavation shall be considered for hierarchy
reinforcement or pre- reinforcement of the lowest part of the
slope, such as prestressed cables, pre-reinforced piles and sheet
pile walls. In general, the height of the slope shall be controlled
within 25.0m. As the strata of the hard rock along this line is
old, the joints are developed and the rocks are crushing, grass
window wall shall be used for the slope or the slope shall be
closed.
3) The slope rate for excavation of the cutting slope of
weakly–slightly weathered hard rock shall be determined based on
rock lithology, degree of weathering, level, geological structure,
groundwater and required allocation of earth and stone. If the
slope height is not greater than 24.0m and there are no lots with
adverse impact on the structure surface, retaining wall, concrete
grass window slope, wall and frame anchored rod shall be used for
protection, with the height of the retaining wall not greater than
8.0m. If the height of the wall exceeds 6.0m, temporary shotcrete
shall be taken for the excavated slope of the back of the wall. If
the slope height is greater than 24.0m or there are lots with
adverse side effects of structure and broken lithology, stratified
excavation shall be considered for hierarchical reinforcement or
pre-strengthening of the foot of the slope. The slope height of
weak–slight weathered hard rock cutting shall, in general, be
controlled within 30.0m. Finishing or pre-split blasting shall be
used for the slope within the thickness of 3.0m, and M10 mortar
rubbles shall be embedded. Hollow bricks with new soil grass shall
be used inside the concrete grass windows or frame anchored rods
and cables.
4) Planting tanks in which japanesecreepers and evergreen low
shrubs are planted shall be located at the platform of the side
trenches in the cutting where retaining wall, pile wall and
protection wall are located and the platform from the foot of the
flooding closed slope lot to the drainage.
5) In the lots with absence of A, B group packing, if the
cutting soil is sand gravel or hard rock, depressed road's
extension shall be designed and large platform shall be reserved
for the foot and side slope of cutting slope, with one level every
8.0 ~ 10.0m, and the slope rate shall be reduced accordingly. C25
concrete grass window shall be used for the slope protection.
(5) Expansion rock (soil) cutting slope protection
1) The slope design of expansion rock (soil) excavation shall
follow the principle of "reduced slope rate, wide platform,
reinforced toe, enhanced drainage and appropriate slope
protection". The excavation height shall be generally controlled
within 15.0m. The rating of the slope height shall not be more than
6.0m. If the slope height of the cutting is less than 10.0m, the
slope rate is generally 1:1.75 for weak swelling rock (soil), 1:2.0
for moderate swelling rock (soil), and 1:2.25 - 1:2.5 for strong
expansion rock (soil). The width of the slope platform shall not be
less than 2.0m for weak expansion rock (soil), and not less than
3.0m for medium and strong expansion rock (soil).
2) If the slope height of the cutting is less than 3.0m, the use
of hollow bricks with new soil grass + planted shrubs shall be made
for protection; if the slope height is greater than 3.0m but less
than 10.0m, the use of hollow bricks with new soil grass and
planted shrubs in C25 concrete water disconnection frame (expansion
soil) or C25 concrete grass window (expansion rock) shall be made
for protection; if the slope height is equal to or greater than
10.0m, a platform in a width of 3.0 ~ 6.0m shall be located at the
slope of expansive soil cutting, hollow bricks with new soil grass
and planted shrubs in C25 concrete water disconnection frame
combined with supporting sewer shall be used for protection; if the
slope is equal to or greater than 10.0m, hollow bricks with new
soil grass and planted shrubs in framework anchoring rod (or
anchoring cable) combined with supporting sewer shall be used for
the protection of the slope of expansion rock. The thickness of the
main frame of the C25 concrete water disconnection framework shall
not be less than 0.8m, and that of the supporting frame shall be
0.6m. The main frame spacing and the spacing between arches is
3.0m.
(6) Loess cutting slope protection
The excavation height of loess cutting slope is commonly
controlled within 20.0m. Side-ditch platform in a width of 2.0 ~
3.0m shall be located at the loess cuttings along the line. M10
cement mortar rubble or concrete solid block masonry shall be used
for the platform.
If the cutting slope height H is ≤ 5.0m, concrete hollow bricks
with new soil grass and planted shrubs inside shall be used for the
slope protection. If the slope height is: 5.0m (7) Cutting of
groundwater development
The slope rate shall be reduced by level 1~2 compared with the
groundwater undeveloped section. C25 concrete grassed window or C25
concrete arched water disconnection frame + three-dimensional
vegetation network solid soil grass + planted shrubs shall be used.
The net frame spacing shall be 2.5m and the main frame shall be
0.8m thick. Water disconnection tank shall be reserved at the top,
and supporting sewer in a width of 2.0m and a depth of 2.0~2.5m
shall be located every 10.0~15.0m. At the junction of permeable and
impermeable sections, a slope platform in a width of 3.0 ~ 5.0m
shall be located with drainage ditches in it.
(8) Subgrade drainage works1) Surface drainage design
1 Side ditches, gutters, drains or drainage ditches shall be
designed by the slope rate of 1/50, and the top shall be 0.2m
higher than the designed water level. The longitudinal slope rate
shall not be less than 2‰. The cross-section dimension of water
surpassing for drainage facilities shall be calculated based on
water flow. The connection with subgrade surface drainage, slope
drainage and sub drainage systems shall be paid attention to.
2 If the subgrade slope is protected with water disconnection
framework, the slope water disconnection tanks on both sides will
be the lateral gutters along the subgrade slope. Lateral gutters
along the slope shall be located in the lots where C25 precast
concrete hollow brick grassed pavement in a depth of 0.2m and a
spacing of 10.0m is used.
3 In the lots where cross slope is significant on the subgrade
ground, drainage ditches may be located in the top side. If the
ground cross slope is not obvious, drainage ditches shall be
located on both sides of the subgrade. Drainage plane shall be
straight; if a turn is required, its radius shall not be less than
10.0~20.0m, and the length of the gutter shall be determined
according to the actual needs. Drains are generally trapezoidal
ditches in a bottom width of 0.4m and a depth of 0.6m with a slope
rate of 1:1. Cast-in-site C30 reinforced concrete in a thickness of
0.2m shall be used for drainage ditches. The location of drains
shall ensure that the water will be led outside the subgrade to
prevent it from erosion.
4 C30 reinforced concrete rectangular cover trench shall be used
for side ditches in a bottom width of 0.6m, a height of 0.8m, and a
thickness of 0.25m. The drains between the lines in a standard
spacing shall have a width of 0.4m, a depth of 0.8m, and a
thickness of 0.20m in C30 reinforced concrete masonry. Precast C30
reinforced concrete shall be used for the cover of the side ditch.
Trapezoidal side ditch shall be used for non easily weathered hard
rock cutting, in a bottom width of 0.4m, a depth of not less than
0.6m and a slope rate of 1:1. M10 cement mortar in a thickness of
0.08m shall be used for the surface, and C25 concrete may be used
for embedment at local sections.
5 In the lots where cross slope is significant on the subgrade
ground, gutters may be located in the top side. If the ground cross
slope is not obvious, gutters shall be located on both sides of the
subgrade. 0.2m thick in-situ C30 reinforced concrete may be used
for the gutters, and M10 mortar rubble shall be used to close the
sections from expansive rock (soil), collapsible loess, the top of
the bed cutting to the gutter. For the gutter which has the steep
slope of the cutting top, rectangular gutter shall be used.
6 0.40m × 0.40m rectangular groove shall be used for the water
disconnection ditch at the slope platform for the cutting, and C25
concrete which is used in the slope shall be poured.
7 The anti-slope drainage of the tunnel entrance is based on the
rigid transition section of the tunnel road, with the cross section
of the ditch at the starting position being 0.4m deep. In the deep
cutting and the lot with problems of anti-slope drainage(if the
depth of the side ditch is more than 1.50m, and the width more than
0.80m), and in the valley cutting lots, the addition of culverts
and the use of 0.2m thick C30 reinforced concrete drains shall be
made to lead the side ditch water out of the subgrade as soon as
possible.
2) Base-bed waterproofing and drainage
Collecting well shall be located in the middle of the subgrade
for the drainage between the tracks of slab track sections of
straight lines and curves lines. The inside diameter of the
drainage well is 0.6m, the depth 0.8m, and 0.3m thick cast-in-site
C30 reinforced concrete is used. Precast C30 reinforced concrete is
used for the cover spaced 50m or so, which are embedded into the
drainage channels or side trenches for the slope of subgrade.
3) Groundwater waterproofing and drainage facilities
Drainage facilities such as open ditches, slope support sewers
and porous drains shall be located where underground water brings
hazards to the subgrade according to its nature and
characteristics. Drainage shall be particularly designed for
swelling rock (soil) cutting and underground water development
cutting.
4) Connection between drainage system and natural system
The drainage system of subgrade main project uses its drains
with devices such as wells and settling ponds by being connected to
the existing ditches or channels around.
The subgrade slope protection, slope greening measures, drainage
works, protective area, quantity and investments of protection, etc
taken in the design shall meet water security requirements, and be
included in this program investment. For the quantities of soil
stripped and corresponding temporary protective measures excluded
in the main project list, design will be added to them in the
program. Special design of green channel is made for the both sides
of the line in the main works, and costs are listed to meet water
conservation requirements, but detailed design has not been made in
the main engineering. Therefore it is not very targeted and
operable, and may not be implemented specifically in the
construction process. This soil and water conservation program has
detailed design for the greening sections on both sides of the
line, and quantities and investment costs of protection works based
on sections have been included.
Table 2 Subgrade slope protection measures
No
Landform
Milestone
Administration
Slope protection
3-d ecological slope protection
TGSG25
Fence
Greening protection
Concrete block
Planting pool
Grass
Soils
River locust tree
Creepers
C25Concrete block
C25 concrete
Planting soil
Fertiliezer
Water outlet
3-d slope protection
M type bag
PVC pipe(φ0.05m)
m2
m2
m3
Nr
/
m3
m3
m3
m3
m
m2
Nr
1
Plain
CK000+000~CK002+570
Zhangjiakou
640
170
17
1595
7
2
Plain
CK002+570~CK011+260
Wangquan
26749
5208
521
48879
235
3
Plain
CK011+260~CK068+300
Huai’an
488848
49703
4972
471572
102732
2005
935
3931
393
1868
4
Hills
CK068+300~CK073+310
Shangyi
5
Hills
CK073+310~CK074+560
Xinghe
6
Hills
CK074+560~CK076+900
Shangyi
36
4
342
2
7
Hills
CK076+900~CK124+215
Xinghe
139051
110007
14512
1075442
37444
4789
830
2382
237
1659
19443
136101
8
Hills
CK124+215~CK151+080
Chanyouqianqi
24209
20306
4186
200455
1755
1017
106
309
31
213
9
Plain
CK151+080~CK152+303
Jining
10
Pain
CK152+303~CK160+796
Chayouqianqi
20711
4466
447
41918
177
28292
198044
11
Pain
CK160+796~CK163+498
Jining
7700
2648
265
24855
379
102
47
139
14
95
12
Hills
CK163+498~CK179+317
Chayouqianqi
4673
12000
1201
120208
5000
459
109
347
34
218
13
Hills
CK179+317~CK255+248
Zhuozi
111646
117330
13246
1114323
36806
4794
657
2007
202
1310
16139
114233
14
Hills
CK255+248~CK269+500
Hohhot
55511
27715
3773
262277
8665
1199
166
476
47
336
15
Plain
CK269+500~CK291+000
Hohhot
181362
35064
3504
329095
47423
1358
429
1810
182
861
16
Hills
Sections by Second Jibaoline
Hohhot
1053
2407
241
22599
1108
17
Plain
Section by Jingbao line(double line)
Hohhot
57012
16711
1672
156851
48779
Total
1119165
403771
48561
3870411
240204
66031
3279
11401
1140
6560
64054
448378
(Continued)
No
Landform
Milestone
Administration
Slope protection
Reinforce
Interception structure slope protection
Concrete(window type)wall
Geotextile,etcs
Grooving
C25 Concrete
M10concrete structure
Wall body
Filter layer
Water outlet
Expansion joint
Soil
Stone
M10
C25
concrecte block
Sand/grabble
PVC管(φ0.1m)
Alphalt linen(0.02m)
m3
m3
m3
m3
m3
m3
m3
m
m2
m2
1
Plain
CK000+000~CK002+570
Zhangjiakou
48
49
394
2
Plain
CK002+570~CK011+260
Wangquan
282
283
15242
3
Plain
CK011+260~CK068+300
Huai’an
15871
63
16005
266199
4
Hills
CK068+300~CK073+310
Shangyi
5
Hills
CK073+310~CK074+560
Xinghe
6
Hills
CK074+560~CK076+900
Shangyi
176
7
Hills
CK076+900~CK124+215
Xinghe
26662
5481
32272
363902
8
Hills
CK124+215~CK151+080
Chanyouqianqi
4831
668
5520
68226
9
Plain
CK151+080~CK152+303
Jining
10
Plain
CK152+303~CK160+796
Chayouqianqi
1627
1634
7238
11
Plain
CK160+796~CK163+498
Jining
627
630
16712
12
Hills
CK163+498~CK179+317
Chayouqianqi
923
2171
3108
41764
13
Hills
CK179+317~CK255+248
Zhuozi
30473
2215
32835
8578
45
299
2589
897
381687
14
Hills
CK255+248~CK269+500
Hohhot
9331
35
9409
79156
15
Plain
CK269+500~CK291+000
Hohhot
22796
23921
244173
16
Hills
Sections by Second Jibaoline
Hohhot
1228
2998
17
Plain
Section by Jingbao line(double line)
Hohhot
6043
10389
Total
120115
11260
125666
13387
8578
45
299
2589
897
1484869
Table 3 Subgrade Drainage Protection Measures`
No
Landform
Milestone
Administration
Ground drainage ditch
Water collection well
Side ditch
Side ditch platform
drainage ditch
Gutter
Joint
Well body
Cover
C30
Concrete
M10 cement surfacing(0.05m)
M10
M10 cement surfacing (0.05m)
M10
C30 Concrete
Soils
M10
C30 concrete
Soils
Soils
M10
C30Concrete
C30Concrete
(m3)
(m2)
(m3)
(m2)
(m3)
(m3)
(m3)
(m3)
(m3)
(m3)
(m3)
(m3)
(m3)
(m3)
1
Plain
CK000+000-CK002+570
Zhangjiakou
17
12
12
27
2
Plain
CK002+570-CK011+260
Wangquan
938
2095
9
1
3
Plain
CK011+260-CK068+300
Huai’an
4949
9313
3479
12327
18884
408
2791
6355
8093
1491
158
19
4
Hills
CK068+300-CK073+310
Shangyi
5
Hills
CK073+310-CK074+560
Xinghe
6
Hills
CK074+560-CK076+900
Shangyi
15
10
6
13
7
Hills
CK076+900-CK124+215
Xinghe
23246
16864
71
4613
6643
10643
23952
2847
30
209
22
8
Hills
CK124+215-CK151+080
Chanyouqianqi
4432
2457
3211
1489
355
541
2361
5228
232
39
5
9
Plain
CK151+080-CK152+303
Jining
10
Pain
CK152+303-CK160+796
Chayouqianqi
445
696
298
4
11
Pain
CK160+796-CK163+498
Jining
1218
341
297
465
411
1972
199
10
1
12
Hills
CK163+498-CK179+317
Chayouqianqi
2999
3090
1715
2504
113
333
399
1357
3055
170
48
23
2
13
Hills
CK179+317-CK255+248
Zhuozi
25114
13720
3477
201
8544
9453
272
12214
234839
4051
100
220
18
14
Hills
CK255+248-CK269+500
Hohhot
4220
2398
1100
737
2353
2142
3322
1008
550
45
6
15
Plain
CK269+500-CK291+000
Hohhot
5503
4084
10941
15480
723
1604
6633
102
11
16
Hills
Sections by Second Jibaoline
Hohhot
574
66
99
96
460
653
41
17
Plain
Section by Jingbao line(double line)
Hohhot
1168
1197
7176
10531
42
74
4515
3075
Total
73455
5547
52931
7470
16335
39545
91699
722
33108
281067
4038
1099
819
85
2.2 Plant protection measures for both sides of the subgrade
In order to improve the environmental quality of the project
area, reduce soil erosion caused by railway construction, while
achieving the purposes of soil and water conservation,
afforestation and beautification as well as the protection of
railway operational safety, protection of plant measures shall be
made for the both sides of the subgrade. Based on the site
conditions in climate, soil, and water, the available lots on both
sides of the subgrade within the land in the project may be greened
under the principle of "trees and shrubs integrated", and green
protective measures may not be taken for the lots without the space
for green.
Green protective measures shall be taken for the available lots
within the boundary of the land on both sides of the line with the
total length of the green lots being 99.23km. A combination of
planted bushes and trees will be taken for Hebei section, and
shrubs will be planted in the Inner Mongolia section. Specific
green measures for the Hebei section will be the following: one row
of trees and two rows of shrubs will be planted at either side of
the subgrade lot; three rows of shrubs planted on both sides of the
cutting lot; the tree spacing will be 3.0×1.0m, shrub spacing
1.0m×1.0m; for the Inner Mongolia, the specific measures will be
the following: three rows of shrubs will be planted on either sides
of the subgrade lot in a spacing of 1.0m×1.0m. A total of 10,696
trees and 1,747,256 shrubs will be planted on both sides of the
subgrade areas along the whole line.
Table 4 Greening along subgrade
No
Landform
Milestone
Administration
Subgrade length(km)
Greening quantity
Trees
Bushes
1
Plain
CK000+000~CK002+570
Zhangjiakou
0.02
15
268
2
Plain
CK002+570~CK011+260
Wangquan
0.87
577
10392
3
Plain
CK011+260~CK068+300
Huai’an
15.16
10104
181867
4
Hills
CK068+300~CK073+310
Shangyi
0.00
0
0
5
Hills
CK073+310~CK074+560
Xinghe
0.00
0
0
6
Hills
CK074+560~CK076+900
Shangyi
0.01
0
180
7
Hills
CK076+900~CK124+215
Xinghe
22.27
0
400775
8
Hills
CK124+215~CK151+080
Chanyouqianqi
3.88
0
69777
9
Plain
CK151+080~CK152+303
Jining
0.00
0
0
10
Plain
CK152+303~CK160+796
Chayouqianqi
2.61
0
47003
11
Plain
CK160+796~CK163+498
Jining
0.95
0
17092
12
Hills
CK163+498~CK179+317
Chayouqianqi
2.37
0
42713
13
Hills
CK179+317~CK255+248
Zhuozi
23.39
0
420965
14
Hills
CK255+248~CK269+500
Hohhot
4.50
0
80953
15
Plain
CK269+500~CK291+000
Hohhot
16.77
0
301831
16
Hills
Sections by Second Jibaoline
Hohhot
0.65
0
11653
17
Plain
Section by Jingbao line(double line)
Hohhot
8.99
0
161787
Total
102.42
10696
1747256
(1) Temporary block and drainage measures for the subgrade
stripped topsoil
During the filling works of the railway subgrade, as the surface
soil fails to meet the requirements of subgrade filling in the
engineering design, the topsoil must be stripped. The thickness of
this surface soil is generally about 30cm. It has high content of
humus, featuring good soil fertility, structure and texture. It is
suitable for vegetation growth and may be used in the topsoil
transformation for the subgrade slope green of grid, station and
ballast along the railway.
According to the state of the environment in the project area,
combined with the engineering characteristics, the land, woodland
and grassland occupied by the subgrade are designed to have topsoil
stripping in a strip thickness of 0~30cm, and a temporary
stockpiling field is designed every 500~1000m in the land, where
the stripped topsoil will be piled up and compacted. Retaining wall
made of straw bags will be used as temporary protection at the foot
of the outside slope surrounding the stockpiled soil, and other
exposed surfaces will be covered with tarpaulin to prevent wind
transport. Temporary drains will be dug at the border of the
stockpile soil, temporary settling basin will be constructed at the
outlet, and connected with the surrounding drainage system, so that
the rainfall runoff may be discharged through the outlet and the
simple settling basin to prevent soil erosion in the temporary
stockpiling field.
The stockpiling height of the temporary stockpiling filed shall
not be higher than 3.0m, and the stacked slope rate shall be
controlled within 1:1.5. The straw bag retaining wall section shall
be a rectangular trapezoidal cross-section in height × top width
×bottom width = 1.0m × 0.5m × 1.5m. When piling, the bags shall be
engaged and lapped in a lap length not less than 1/3 of the length
of the straw bag. The temporary drains shall be soil drains with a
trapezoidal cross-section, whose design specifications are base
width of 0.3m, top width of 0.9m, ditch depth of 0.3m and slope
rate of 1:1. The ditch base and wall shall be compacted. The simple
settling basin shall have a length of 2.0m, a width of 1.0m, and a
depth of 1.5m, with its bottom compacted. A total of 89.57 × 104m3
topsoil used in the new soil grass of subgrade slope are stripped
for the subgrade across the line.
Table 5 Temporary protection and drainage design for top soil
from subgrade area
No
Landform
Milestone
Administration
Topsoils(m3)
Soil cover(m3)
Length(m)
Soil bags(m3)
Paulin(m2)
Temporary drainage(m3)
Temporary settling tank
1
Plain
CK000+000~CK002+570
Zhangjiakou
0
0
0
0
0
0
0
2
Plain
CK002+570~CK011+260
Wangquan
10060
10060
409
409
4024
0
0
3
Plain
CK011+260~CK068+300
Huai’an
182420
182420
6960
6960
72968
0
0
4
Hills
CK068+300~CK073+310
Shangyi
14980
14980
610
610
5992
434
3
Hills
CK074+560~CK076+900
Xinghe
5
Hills
CK073+310~CK074+560
Shangyi
Xinghe
282560
282560
10901
10901
113024
7048
47
Hills
CK076+900~CK124+215
6
Hills
CK124+215~CK151+080
Chanyouqianqi
Jining
55376
55376
2054
2054
22150
1366
9
7
Plain
CK152+303~CK160+796
8
Plain
CK151+080~CK152+303
Chayouqianqi
Jining
0
0
0
0
0
0
0
9
Plain
CK160+796~CK163+498
10
Hills
CK163+498~CK179+317
Chayouqianqi
13844
13844
469
469
5538
334
2
11
Hills
CK179+317~CK255+248
Zhuozi
228200
228200
8629
8629
91280
5661
38
12
Hills
CK255+248~CK269+500
Hohhot
43320
43320
1600
1600
17328
1068
7
13
Plain
CK269+500~CK291+000
Hohhot
64980
64980
8664
8664
25992
0
0
14
Hills
Sections by Second Jibaoline
Hohhot
0
0
0
0
0
0
0
15
Plain
Section by Jingbao line(double line)
Hohhot
0
0
0
0
0
0
0
Total
895740
895740
40296
40296
358296
15911
107
Protective measures for Station3.1 Station subgrade
protection
The water and soil conservation measures for the station in this
project is mainly aimed at the station subgrade, which are roughly
the same as the soil and water conservation measures for the
subgrade. Slope protection of arched frame pavement, hollow bricks
with new soil grass and mortar rubble drainage ditch and porous
drain are used for the subgrade. If the subgrade slope height is
less than 3.0m, six-diamond hollow bricks with planted grass and
Amorpha will be used for protection, and a precast concrete
drainage tank will located at both sides of the slope at intervals
of 10.0m to connect the horizontal drainage channels between the
tracks; if the slope height is greater than 3.0m, 3×3m C25 concrete
arch framework with water disconnection tank will be used in the
slope protection of the subgrade, and in the framework, six-diamond
hollow bricks will be paved with planted grass and Amorpha. A layer
of two-way stretch plastic geogrid (TGSG30-30) will be laid every
0.6m of the vertical height from the foot of the slope to the
surface level of the base bed within the lateral width of 3.0m on
both sides of the slope; if the subgrade is filled with weak
weathered and slightly weathered broken rocks, the quantity of new
soil shall be added into the block.
The cutting slope rate shall be 1:1.25~1:1.5 for silty clay,
1:1.25 for gravel soil, and 1:1.25 for loess cutting. For the slope
whose height is less than 3.0m, six-diamond hollow bricks with
planted grass and Amorpha inside shall be used for protection; for
the slope whose height is greater than 3.0m, C25 concrete arch
frame paved with six-diamond hollow bricks with planted grass and
Amorpha inside shall be used for protection.
The stations are open-train layout, and the new sites are ground
stations except that Huai An Station is an elevated one. The
average earthwork height in plains is h≤ 3m (Huan An Station),
3m
3.2 Greening measures in the station area
There are three new stations across the line, with Trunk of
treesozi Station and Trunk of treesozi East Station under the
construction being integrated for locations. In order to maintain
soil and water and beautify the station area environment, to
improve ecological environment quality of the station area, and to
meet the production and operating conditions, 20% of the new
permanent site in the station are greened in line with the
principle of multiple green. They are mainly located at the
surrounding of the new buildings at each station and other open
space available for concentrated green. Trees, shrubs, flowering
shrubs and grass are integrated, in a green ratio of 30% by trees,
shrubs 30%, flowering shrub 20%, and grass 20%, laid according to
the principle of 3×3m for trees and 1 × 1m for shrubs. In the new
stations, as Huai An Station is an elevated one, green design is
considered for its areas available for green at the roads in the
stops. The proportion of shrubs, flowering shrubs and lawns is 30%,
30% and 40% respectively. The shrubs are laid in 1× 1m. A total of
3,523 trees, 34,898 shrubs, 9,532 flowers and 4,958m2 paved turf
are planted in the stations across the line.
Table 6 Greening measures in the station area
No
Landform
Station
Milestone (center)
Greening area(m2)
Greening
Trees
Bush
Grass(m2)
Flowers(m2)
1
Plain
Huai’an Station
CK043+075
10633
0
3190
4253
3190
2
Hills
Xinghe North Station
CK099+400
30560
1019
9168
204
1834
3
Plains
Ulanchabu Station
CK159+270
54933
1831
16480
366
3296
4
Hills
Zhuozi East Station
CK207+200
20200
673
6060
135
1212
Total
116327
3523
34898
4958
9532
3.3 Temporary block protection and temporary drainage measures
for stripped topsoil in the station area
22.25 × 104m3 stripped topsoil in the new stations across the
line is used for the latter stage green in the station. The
stripped topsoil will be designed to be piled in the temporary
stockpiling site in the station area, and they will be compacted.
Retaining wall made of straw bags will be used as temporary
protection at the foot of the outside slope surrounding the
stockpiled soil, and other exposed surfaces will be covered with
tarpaulin. Temporary drains will be dug at the border of the
stockpile soil, temporary settling basin will be constructed at the
outlet of the drains, and connected with the surrounding drainage
system.
The stockpiling height of the temporary stockpiling filed shall
not be higher than 3.0m, and the stacked slope rate shall be
controlled within 1:1.5. The straw bag retaining wall section shall
be a rectangular trapezoidal cross-section in height × top width
×bottom width = 1.0m × 0.5m × 1.5m. When piling, the bags shall be
engaged and lapped in a lap length not less than 1/3 of the length
of the straw bag. The temporary drains shall be soil drains with a
trapezoidal cross-section, whose design specifications are bottom
width of 0.3m, top width of 0.9m, ditch depth of 0.3m and slope
rate of 1:1. The ditch base and wall shall be compacted. The simple
settling basin shall have a length of 2.0m, a width of 1.0m, and a
depth of 1.5m, with its bottom compacted. The stripped topsoil is
used in the surface soil transformation of green area in the
station.
Table 7 Temporary protection and drainage design for
stations
No
Landform
Station
Milestone
Toposoils(m3)
Soil cover(m3)
Length(m)
Soil bags(m3)
Paulin(m2)
Temp. drainage(m3)
Temp. Settling tank
1
Plain
Huai’an Station
CK043+075
29500
29500
1118
1118
11800
0
0
2
Hills
Xinghe North Station
CK099+400
45840
45840
1801
1801
18336
1012
4
3
Plain
Ulanchabu Station
CK159+270
38252
38252
1496
1496
15301
0
0
4
Hills
Zhuozi Station
CK207+200
27840
27840
1301
1301
11136
652
2
5
Plains
Hohhot Station(yard)
CK289+273
27000
27000
1064
1064
10800
0
0
6
Plains
Hohhot Station(Utility Yard)
CK291+000
54100
54100
2044
2044
21640
0
0
Total
222532
222532
8824
8824
89013
1664
6
Table 8 Main Protection Measures for Stations
Station
Station subgrade reinforce
Geotextile
Grassing
River locust tree
Soils
Concrete structure shoulder
M10 cement surfacing
C25 Concrete
M7.5 Concrete
C30 Concrete
Units
m2
m2
/
m3
m3
m2
m3
m3
m3
Huai’an Station
Xinghe North Station
34269
1073
18
Ulanchabu Station
54308
1518
26
Zhuozi East Station
37972
1190
20
Hohhot Station(yard)
140463
11866
76284
1187
3044
9202
1268
Hohhot Station(Utility Yard)
10382
67085
1229
1000
3023
2493
2784
Station
Station drainage system
Side ditch of sugrade
Drainage
Drainage or gutter
Joint
Earth work quantity
Side ditch length
C30 Concrete
Side ditch platform M10 concrete
Length
M7.5 Concrete
Drainage length
C30 Concrete
Foundation earth work
Earth work quantity
M10 Concrete
Units
m3
m
m3
m3
m
m3
m
m3
m3
m3
m3
Huai’an Station
Xinghe North Station
1925
4015
955
440
470
846
2915
1437
7288
825
220
Ulanchabu Station
1732
800
955
440
1165
1049
3600
1952
9900
743
220
Zhuozi East Station
1745
700
865
419
543
489
1875
1371
6953
748
179
Hohhot Station(yard)
11802
6744
5852
2833
2070
1863
5212
2570
13030
5058
1213
Hohhot Station(Utility Yard)
3490
3141
Control Measures in the Bridge and Culvert Works Area4.1 Bridges
and culverts set-up and design requirements
The flood frequency of bridges and culverts is designed to be
1/100 for bridges, and 1/100 for culverts. In principle, one bridge
(culvert) is set up for one river (ditch), and the river channel
shall not be compressed, so that the water may go through the
bridge in a natural state; where roads are crossing, interchange
may be used; in the farming-intensive areas, farmland channel shall
be located; vertical drains shall be located within the bridge, and
connected with the drainage system in the subgrade so as to lead to
the water in the side ditches of the subgrade to the natural
ditches under the bridge. M10 mortar rubble paving protection shall
be adopted.
Permeable soil shall be used to fill the cone packing of the
bridge ancillary works and be compacted, and 35cm thick M20 mortar
rubble shall be used in the protection of slope with a 10cm thick
gravel layer located below.
For individual lots where river erosion may be increased due to
the set-up of piers, reinforced subgrade and mortar rubble
revetment measures shall be taken to avoid the river, flood
erosion. The bridge foundation excavation shall be made full use
of; if it is unable to use, spoil field shall be selected for
concentrated spoil to reduce soil erosion.
The foundation of the main pier crossing the river shall use
island or cofferdam construction and shall avoid flood. Complete
cleanup shall be considered after the construction to ensure the
smooth water flow.
4.2 Bridge and culvert protective measures
(1) The flood frequency of 1/100 is used in the design of the
bridge and culvert to maintain the appropriate technical
requirements; for the check calculation of extra large bridge (or
large bridge) which is technically complex, difficult to repair or
very important, the flood frequency is 1/300; for the bridge close
to the upstream reservoir, check calculation will be made according
to the reservoir dam break flow.
(2) Natural river channel shall be avoided from compress and
ditches from change when crossing the river channel for flood
discharge so as to maintain the natural run-off state and to ensure
smooth flow of flood discharge. Streamlined piers shall preferably
be used in the river channel to reduce the water-blocking area of
the pier, and avoid increased erosion, as well as to reduce the
impact on the upstream and downstream slopes of the bridge site and
to avoid soil erosion.
(3) Flood discharging capacity is fully considered in the design
of the diameter of the culvert to avoid the water restrain of the
culvert caused by the small aperture, resulting in soil erosion
caused by increased downstream erosion.
(4) For the pier located in the ditch or in the water, cofferdam
made of straw bags filled with soil or steel sheet pile cofferdam
is used based on the water depth in the construction and geological
conditions, and the protection of the sections where the water
level is high and the foundation layer is strongly permeable shall
be paid attention to in the construction.
(5) During the construction, the spoil generated in the bridge
foundation construction shall be knocked into the pile foundation
if permitted by conditions; abutment cone slope shall be protected
by M20 cement mortar rubble.
Table 9 Bridge and viaduct protection measures
No
Landform
Milestone
Administration
Cone protection
Construction protection
M20 Concrete(m3)
M10 Concrete(m3)
Soil weir(m3)
Steel weir(Number)
1
Plain
CK000+000~CK002+570
Zhangjiakou
125
1413
2
Plain
CK002+570~CK011+260
Wangquan
110
0
0
3
Plain
CK011+260~CK068+300
Huai’an
1178
10375
200
4
Hills
CK068+300~CK073+310
Shangyi
5
Hills
CK073+310~CK074+560
Xinghe
6
Hills
CK074+560~CK076+900
Shangyi
7
Hills
CK076+900~CK124+215
Xinghe
2099
8181
14
8
Hills
CK124+215~CK151+080
Chanyouqianqi
545
35300
0
9
Plain
CK151+080~CK152+303
Jining
10
Pain
CK152+303~CK160+796
Chayouqianqi
137
0
0
11
Pain
CK160+796~CK163+498
Jining
95
0
0
12
Hills
CK163+498~CK179+317
Chayouqianqi
404
0
0
13
Hills
CK179+317~CK255+248
Zhuozi
3803
5267
8
14
Hills
CK255+248~CK269+500
Hohhot
862
0
9
15
Plain
CK269+500~CK291+000
Hohhot
480
273
0
0
16
Hills
Sections by Second Jibaoline
Hohhot
17
Plain
Section by Jingbao line(double line)
Hohhot
195
Total
10032
273
60536
231
4.3 Temporary protection measures for bridge and viaduct(1)
Temporary measures to deal with bored pile foundation mud for the
bridge
To minimize the pollution of the water quality of the rivers
along the line by the bridge drilling mud, bored pile foundation of
the bridge crossing river is usually constructed during the dry
season, and mud pump is installed in steel casing barrel to raise
the drilling mud to the land TWA at both ends. The slurry generated
during the bored pile foundation construction shall be temporarily
processed to reduce soil erosion during construction.
There are a total of two bridges which cross a river and possess
piers in the water in this project. They are the extra large Yanghe
Bridge and extra large No. 4 Daheihe Bridge. Before the drilling of
the piers, one mud pool (seepage control shall be done to the mud
pond, and multiple drilling can be shared) and two settling tanks
are built in the temporary construction site. They are used in
series to make the wall protection mud separate from the ballast.
The mud precipitated shall be recycled, and the surface dust and
ballast of the sedimentation tanks shall be dehydrated at the
dumping ground. The effluent of the sedimentation tank discharges
into natural rivers through the nearby agricultural irrigation
ditches. During the drilling and the hole cleaning in the pier
foundation construction process, mud cars are used to transport the
mud to the designated location. The excavation earth from mud pools
and the sedimentation pond is piled near the pier and compacted. It
will be used in the pier foundation and the backfill of the mud
pools and the sedimentation tanks after the construction.
The volume of each mud pool is designed to be 8m3, and the
length, width and depth to be 2m. The volume of each sedimentation
tank is designed to be 6m3, the length and width 2m, and the depth
1.5m.
Table 10 Bridge slurry pond and sedimentation tank
No
Landform
Milestone
Administration
Slurry tank
Settling tank
1
Plain
CK000+000~CK002+570
Zhangjiakou
2
4
2
Plain
CK002+570~CK011+260
Wangquan
0
0
3
Plain
CK011+260~CK068+300
Huai’an
4
8
4
Hills
CK068+300~CK073+310
Shangyi
0
0
5
Hills
CK073+310~CK074+560
Xinghe
0
0
6
Hills
CK074+560~CK076+900
Shangyi
0
0
7
Hills
CK076+900~CK124+215
Xinghe
2
4
8
Hills
CK124+215~CK151+080
Chanyouqianqi
2
4
9
Plain
CK151+080~CK152+303
Jining
0
0
10
Pain
CK152+303~CK160+796
Chayouqianqi
0
0
11
Pain
CK160+796~CK163+498
Jining
0
0
12
Hills
CK163+498~CK179+317
Chayouqianqi
0
0
13
Hills
CK179+317~CK255+248
Zhuozi
1
2
14
Hills
CK255+248~CK269+500
Hohhot
1
2
15
Plain
CK269+500~CK291+000
Hohhot
0
0
16
Hills
Sections by Second Jibaoline
Hohhot
0
0
17
Plain
Section by Jingbao line(double line)
Hohhot
0
0
Total
12
24
(2) Temporary block and protection measures for excavation stone
earth of the foundation for bridges and culverts
Soil erosion is likely to occur for the excavation earth of the
bridge foundation in the rainy or windy season. Temporary block and
protection measures shall be taken to prevent soil erosion in the
construction process.
After the balance of the excavation earthwork in the bridge
foundation along the line in the project, abandoned earth of 79.00
× 104m3 are resulted. Temporary stockpiling field shall be set up
in the land of the bridge. The temporary stockpiling height shall
not be higher than 3.0m, and the pile slope rate shall be
controlled within 1:1.5. The straw retaining wall section shall be
set in the form of a rectangular trapezoidal cross-section with
height ×top width× bottom width = 1.0m × 0.5m × 1.5m, and during
the piling, the straws shall engage and lap each other, with the
lap length not less than the length of 1/3 of the straw. Temporary
stockpiling soil shall be centralized and piled in straw block
protection. After the construction, timely backfill and clean up
shall be made, and extra earth shall be abandoned in time in the
earth fetching field nearby so as to avoid new soil erosion caused
by rainfall runoff or wind erosion.
Table 11 Temporary measures for foundation building for bridge
and viaduct
No
Landform
Milestone
Administration
Disposal soils(m3)
Fencing & retaining work
Soil bags(m3)
Grass bags
Geotextile(m2)
1
Plain
CK000+000~CK002+570
Zhangjiakou
15347
630
8820
6139
2
Plain
CK002+570~CK011+260
Wangquan
108965
4109
57526
43586
3
Plain
CK011+260~CK068+300
Huai’an
81116
3338
46732
32446
4
Hills
CK068+300~CK073+310
Shangyi
0
0
0
0
5
Hills
CK073+310~CK074+560
Xinghe
0
0
0
0
6
Hills
CK074+560~CK076+900
Shangyi
0
0
0
0
7
Hills
CK076+900~CK124+215
Xinghe
140464
5371
75194
56186
8
Hills
CK124+215~CK151+080
Chanyouqianqi
32915
1291
18074
13166
9
Plain
CK151+080~CK152+303
Jining
0
0
0
0
10
Pain
CK152+303~CK160+796
Chayouqianqi
72139
2726
38164
28856
11
Pain
CK160+796~CK163+498
Jining
51758
2010
28140
20703
12
Hills
CK163+498~CK179+317
Chayouqianqi
16691
656
9184
6676
13
Hills
CK179+317~CK255+248
Zhuozi
154210
5871
82194
61684
14
Hills
CK255+248~CK269+500
Hohhot
70955
2703
37842
28382
15
Plain
CK269+500~CK291+000
Hohhot
43035
13906
194684
17214
16
Hills
Sections by Second Jibaoline
Hohhot
0
0
0
0
17
Plain
Section by Jingbao line(double line)
Hohhot
2483
136
1904
993
Total
790078
42747
598458
316031
(3) Protection measures in the construction of water piers
According to the actual situation of the project, water piers
shall be set up in the river for the new bridge across the river.
Cofferdam measures shall be taken accordingly for the foundation in
the water according to the river channel, water depth, flow rate
and venues. Straw cofferdam and steel sheet pile cofferdam shall be
mainly used to build island in the construction for the project,
and the construction period shall be as far as possible in the dry
season. After the cofferdam is used to build an island in the
river, the construction shall be made in the island, and all waste
ballast and waste water generated in the foundation excavation
shall be transported to shore through the island. They will not be
leaked into the river, and will not have a big impact on the water
quality. When the construction is complete, timely removal of the
cofferdam shall be made, and all cofferdam facilities shall be
transported to the nearest designated spoil site for storage. They
shall neither be dumped in the river, nor flowed into the river
downstream.
Table 12 Protection measures for bridge and viaduct
No
Landform
Milestone
Administration
Cone protection
Construction protection
M20 Concrete(m3)
M10 Concrete(m3)
M20 Concrete(m3)
M10 Concrete(m3)
1
Plain
CK000+000~CK002+570
Zhangjiakou
125
1413
2
Plain
CK002+570~CK011+260
Wangquan
110
0
0
3
Plain
CK011+260~CK068+300
Huai’an
1178
10375
200
4
Hills
CK068+300~CK073+310
Shangyi
5
Hills
CK073+310~CK074+560
Xinghe
6
Hills
CK074+560~CK076+900
Shangyi
7
Hills
CK076+900~CK124+215
Xinghe
2099
8181
14
8
Hills
CK124+215~CK151+080
Chanyouqianqi
545
35300
0
9
Plain
CK151+080~CK152+303
Jining
10
Pain
CK152+303~CK160+796
Chayouqianqi
137
0
0
11
Pain
CK160+796~CK163+498
Jining
95
0
0
12
Hills
CK163+498~CK179+317
Chayouqianqi
404
0
0
13
Hills
CK179+317~CK255+248
Zhuozi
3803
5267
8
14
Hills
CK255+248~CK269+500
Hohhot
862
0
9
15
Plain
CK269+500~CK291+000
Hohhot
480
273
0
0
16
Hills
Sections by Second Jibaoline
Hohhot
17
Plain
Section by Jingbao line(double line)
Hohhot
195
Total
10032
273
60536
231
Control Measures in Tunnel Works Area
There are 25 new tunnels in a length of 59.66km built in this
project. The new tunnels are concentrated in the lots of
mountainous and hilly areas. The longest tunnel is Dajianshan
Tunnel in a length of 15,390m. The excavation of these new tunnels
seeks early hole, and to avoid deep cutting or high slope so as to
minimize the destruction of the mountain and to prevent soil
erosion.
If the tunnel is longer than 500m, dual-port tunneling will be
generally used; if the tunnel length is less than 500m, single-port
tunneling will be generally used. For Grade Ⅳ swelling rock lots,
if the expansion of the rock is medium to strong and the rock is
shallow buried, the method of "temporary invert of three steps "
will be used; if the expansion is medium to strong, the method of "
temporary lateral bracket of three steps" will be used; weak
expansion lots shall as far as possible use the "three-step method"
to strengthen the lock pin bolt, and to strengthen the monitoring
of measurement, so as to reduce the temporary support works. For
the lots of GradeⅤexpansion rock, the shallow buried section shall
adopt the method of "temporary invert of three steps"; and the deep
buried segment may adopt the method of " temporary lateral bracket
of three steps" to reduce the temporary support works. The
ultra-shallow, or seriously pressured lots or sections which have
to go through buildings that require protection shall adopt the
method of "CRD"; collapsible loess sections shall try to use
open-cut method, and the lots which require covered tunneling shall
use the method of "CRD".
5.1 Tunnel body protection
Tunnel entrance shall be chosen to minimize the excavation
height of the side invert slope to reduce the excavation, and the
destruction of land and vegetation. Top-down stratified excavation
and layered protection shall be taken during the hole earthwork
construction. In case of poor geological conditions, measures to
stabilize the side slope and the invert slope shall be taken. The
tunnel waterproofing and drainage shall follow the principle of
"the combination of prevention, disconnection, discharge and block
for local conditions and in comprehensive management", if
necessary, the principle of "block-based, limited discharge" shall
be taken. Appropriate control measures shall be taken according to
the tunnel length, weather conditions, the nature and degree of
development of groundwater to protect the ecological environment.
Fully enclosed lining of tunnel entrances of soil, swelling rock
(soil), and schist formation is adopted for the protection of side
invert slopes at the entrance; the rest of the stone tunnels shall
be protected at the entrances and within 2m of the foot of the
slope. 30cm thick M15 mortar rubble lining shall be used.
Drainage ditches shall be located at the tunnel roof, with the
distance of the drainage ditches from the stone at the top of the
slop excavation line not less than 5m. The soil shall not be less
than 10m so as to intercept surface water so that it may be
imported into the subgrade drainage system, thus avoiding the
formation of new erosion.
5.2 Tunnel spoil protection
The spoil of the new tunnels totals 958.12×104m3. The spoil
field shall be selected to heap the abandoned spoil based on the
factors like topographical conditions near the tunnel along the
line and transport distance.
Retaining wall shall be located at the foot of the slope for the
spoil field, and protected by mortar rubble for the foundation.
After the disposable ballast is carried out, reclamation and
afforestation shall be conducted, and waterproofing and drainage
facilities shall be equipped to prevent soil erosion, and reduce
the impact from drop ballast on the surrounding environment.
Table 13 Tunnel portal protection and drainage measures
No
Landform
Milestone
Administration
Tunnel length(m)
Tunnel number
Tunnel portal, gutter and greening
Interception gutter
Dike
Greening
C25 Concrete(m3)
M10 Concrete(m3)
Soil stone refill(m3)
Planting soil(m3)
Bushes
1
Plain
CK000+000~CK002+570
Zhangjiakou
2
Plain
CK002+570~CK011+260
Wangquan
3
Plain
CK011+260~CK068+300
Huai’an
15390
1
1482
1421
969
4335
4335
4
Hills
CK068+300~CK073+310
Shangyi
5
Hills
CK073+310~CK074+560
Xinghe
6
Hills
CK074+560~CK076+900
Shangyi
7
Hills
CK076+900~CK124+215
Xinghe
5529
3
532
510
348
1558
1558
8
Hills
CK124+215~CK151+080
Chanyouqianqi
3470
2
334
320
219
978
978
9
Plain
CK151+080~CK152+303
Jining
10
Pain
CK152+303~CK160+796
Chayouqianqi
11
Pain
CK160+796~CK163+498
Jining
12
Hills
CK163+498~CK179+317
Chayouqianqi
6602
4
636
609
416
1860
1860
13
Hills
CK179+317~CK255+248
Zhuozi
27328
14
2631
2523
1721
7698
7698
14
Hills
CK255+248~CK269+500
Hohhot
1337
1
129
123
84
377
377
15
Plain
CK269+500~CK291+000
Hohhot
16
Hills
Sections by Second Jibaoline
Hohhot
17
Plain
Section by Jingbao line(double line)
Hohhot
Total
59655
25
5743
5507
3757
16805
16805
Control Measures in Earth-fetching Area6.1 Earth-fetching field
set-up and optimizations
The earth-fetching fields set up along the line are mainly for
the earth fetching of subgrade and station, and the main type of
land is unused land. In the earth excavation works, in the spirit
of the principle of concentrated earth fetching, the construction
shall be made in accordance with the position of earth-fetching
field designed. The expansion of the excavation area is not
allowed, and flayer earth is strictly prohibited. The 0~30cm
surface of the earth-fetching field is prohibited to be used as
fill. The surface layer shall be cleared and stacked before earth
fetching, and when the earthwork is completed, then they shall be
backfilled to the earth pit. Excavator with a dump truck is used to
fetch the earth layer by layer. It is proposed that if the
excavation of soil complies with the requirements of packing, the
slope rate shall be slowed down, and the earth excavation depth may
be enhanced to reduce the project disturbance area. After the
completion of the earth fetching, the slope of the earth field
shall be cut in a gradient of 1:1.5, and the slope shall be slowed
down to facilitate construction operations in an economic and safe
way in preventing collapse and soil erosion. Clean, flatting, green
and other necessary measures shall be taken. In the next stage of
design, each earth field is required to sign an agreement on
fetching and abandoning of soil with the local Land and Resources
Bureau.
6.2 Earth fetching and protection principles
1) The centralized and close earth fetching shall be carried
out, and the priority in the use of the existing earth field shall
be made.
2) The selection of the earth field location shall obtain the
coordination of the local government and the soil and water
conservation authority. The locacation shall be determined through
the consultation in the unified planning of the soil and water
conservation department based on the local water resources,
agricultural development planning, and environmental construction
plan.
3) For the sloping earth field, after earth fetching, the slope
of the excavation area shall be adjusted, the bottom shall be
cleaned and leveled, and green measures of shrub planting shall be
taken.
4) For the earth field ready to restore planting, before earth
fetching, the surface mellow soil shall be pushed aside, and
leveled back after earth fetching. Reasonable temporary protective
measures shall be taken according to the terrain of the temporary
dump.
6.3 Earth field slope cutting and drainage design
In the excavation and earth fetching, the expansion of the
disturbance area shall be avoided, and the lane in a width of 10m
and a longitudinal slope rate of 1:5 shall be reserved for the
access of the earth fetching pit. The lane shall stay in the side
facing the construction area, and the slope rate shall take 1: 1.5.
The slope shall be cut by half-dug and half-fill to the limit of 1/
2 of the excavation depth. The upper earth of cut slope shall be
used to fill the lower slope, and the fill slope shall be
backfilled and compacted layer by layer. To intercept the slope
runoff, and protect the overhead slope formed during earth fetching
from directly impact of wind and water erosion, a retaining ridge
in a height of 80cm and a top width of 50cm shall be built beyond
the upper sloping shoulder of the earth field, and intercepting
drains shall be located at the outside close to the retaining ridge
so that the runoff above the top of the slope will be channeled to
both sides, then discharged to the close ditches. The intercepting
ditch has a bottom width of 0.5m, a top width of 1.5m, and a depth
of 0.6m. The soil ditches of semi-filled and semi- dug section
shall be adopted and interior wall shall be compacted. Base gutters
in a bottom width of 50cm, a depth of 50cm, and a top width of 1m
shall be located at 1m outside the foot of the slope. Soil ditches
shall be used, and interior wall shall be compacted. If the slope
has two platforms, the platform shall be an invert slop directing
toward interior side, namely, the side of the second slope, so as
to create conditions for the casing and the drainage in the future.
Meanwhile, drains shall be located in the middle platform and the
foot of the secondary slope to discharge the slope runoff. The
water in the drains in the middle platform will flow down to lead
the rainfall runoff into natural ditches or the existing drainage
ditch system. The drains in the foot of the secondary slope shall
adopt the same design standard with drains at the bottom of the
slope.
6.4 Plant protection measures in the earth field
After the fetching in the earth field is completed, and when the
engineering measures such as slope adjustment of excavation area,
leveling and cleaning of the underside, casing (casing source is
the topsoil stripped before earth fetching, and the casing
thickness is about 30cm), appropriate plant protection measures
shall be taken on the bottom of the fetching pit, side slope and
platform. Through the green initiatives of sowing grass seed,
planting shrubs, and conservation and management measures of
watering, fertilizing, and soil moisture to ensure seedling
survival rate, the purposes of soil and water conservation and the
erosion control may be achieved. The shrub spacing is 1 × 1m.
A total of 121.00hm2 rehabilitation area will be adopted for the
earth fields across the line, 270,000 shrubs will be planted, and
88.60hm2 grass seed will be spread.
6.5 Temporary protection measures of stripped topsoil in the
earth field
Before the fetching in the earth field, the 0~30cm surface layer
of mellow soil shall be scooped and stacked within the earth field.
No new temporary area shall be used. The bottom of the stockpiled
soil shall be protected with temporary straw. The surface of the
temporary stockpiling shall be smooth and compacted and covered
with a tarp to prevent the erosion of rain runoff. Temporary soil
drains shall be set up around the foot of the stockpiling slope, so
that the water collected may be discharged into the existing
drainage system around to prevent the new soil erosion. After
completion of the earth fetching, the topsoil shall be backfilled
and leveled to facilitate the reclamation and revegetation.
A total of 32.40×104m3 topsoil is stripped in the earth fields
across the line, with the temporary block retaining length of 12,
585m, the stripping topsoil covering tarpaulin of 129,600m2,
temporary drains of 4401m3, and temporary settling basins of
33.
Table 14 Protection Measures for Borrow pits
No
Administration
Location
Area(hm2)
Soils amount(m3)
Re-vegetation and planting protection
Temporary measures for stripping tops soils
Leveling
(hm2)
Bushes
Grassing(m2)
Top soils(m3)
Temp retaining length(m)
Soils in bags(m3)
Grass bag(Nr)
Paulin(m2)
Temp drainage(m3)
Temp settling tank(Nr)
1
Wanquan, Taishizhuang
CK5+000 left 5000m
2.00
64212
2.00
0
20000
0
0
0
0
0
0
0
2
Huai’an Chunfa Company
CK25+000 right 2000m
4.00
185330
4.00
0
40000
0
0
0
0
0
0
0
3
Huai’an Nanxingtun
CK35+500 left 2500m
6.67
293970
6.67
16667
46667
20000
727
727
10178
8000
0
0
4
Huai’an Lijiayao
CK37+300 left 3000m
4.67
164408
4.67
11667
32667
14000
584
584
8176
5600
0
0
5
Huai’an Dukoupu, Caijiantan
CK51+000 left 60m
4.00
180000
4.00
10000
28000
12000
454
454
6356
4800
0
0
6
Huai’an Dukoupu, Manzhoupo
CK57+000 right 1000m
2.00
81177
2.00
5000
14000
6000
227
227
3178
2400
0
0
7
Xinghe, Chengguan, Gaomiaozi
CK80+600left1500m
2.67
95967
2.67
6667
18667
8000
357
357
4998
3200
184
1
8
Xinghe, Chengguan, Qijia
CK91+000 right 300m
1.00
83527
1.00
2500
7000
3000
156
156
2184
1200
73
1
9
Xinghe, Chengguan, Mqiaocun
CK93+400 right 200m
1.00
12481
1.00
2500
7000
3000
156
156
2184
1200
73
1
10
Xinghe, Chengguan, Haoqiancun
CK99+200 right 800m
4.00
110410
4.00
10000
28000
12000
454
454
6356
4800
262
2
11
Xinghe, Chengguan, Dongshihao
CK103+000 left 2000m
4.00
86408
4.00
10000
28000
12000
454
454
6356
4800
262
2
12
Xinghe, Minzutuanjiexiang, Sihihaocun
CK110+400 left 1000m
2.00
45025
2.00
0
20000
0
0
0
0
0
0
0
13
Xinghe, e’erdong, Dianzicun
CK112+000 left 200m
1.00
21570
1.00
2500
7000
3000
156
156
2184
1200
73
1
14
Xinghe, e’erdong,
Dianzicun
CK114+000 right 200m
1.67
29456
1.67
4167
11667
5000
192
192
2688
2000
110
1
15
Xinghe, e’erdong,
Dianzicun
CK117+000~+300 left hill
3.33
46570
3.33
8333
23333
10000
409
409
5726
4000
224
2
16
Chayouqianqi, Pingdiquanzhen, Laijiadicun
CK166+100~+500 right hill
13.33
105476
13.33
33333
93333
40000
1544
1544
21616
16000
878
7
17
Zhuozi, Shibataizhen, Yushugoucun
CK188+000~+600 right hill
3.33
96669
3.33
8333
23333
10000
409
409
5726
4000
224
2
18
Zhuozi, Shibataizhen,hafengjingcun
CK190+000~CK195+000left hill
6.67
53345
6.67
16667
46667
20000
727
727
10178
8000
431
3
19
Zhuozi, Zhuozishan, Dongtan
CK205+100~CK206+600 right hill
6.67
54583
6.67
16667
46667
20000
727
727
10178
8000
431
3
20
Zhuozi, Lihuazhen, Sidaogou
CK247+050left2000m
4.00
173341
4.00
10000
28000
12000
454
454
6356
4800
262
2
21
Hohhot, Saihan, Yulin, Shimengou
CK261+350left3500m
14.00
155089
14.00
35000
98000
42000
1589
1589
22246
16800
916
7
22
Hohhot, Saihan, Yulin, Sanyingyao
CK267+100 right 3200m
5.00
86160
5.00
0
50000
0
0
0
0
0
0
0
23
Hohhot, Saihan, Yulin,Qiannaimobancun
CK274+200left2200m
12.67
182043
12.67
31667
88667
38000
1492
1492
20888
15200
0
0
24
Hohhot, Saihan, Bayan, Tengjiaying
CK280+000left2100m
11.33
97144
11.33
28333
79333
34000
1317
1317
18438
13600
0
0
Total
121.00
2504360
121.00
270000
886000
324000
12585
12585
176190
129600
4401
33
Disposal Sites7.1 Earth disposal site
There are 18 earth disposal sites, total earth disposed will be
4320700m3, occupying 54.8hm2.
7.2 Tunnel spoils disposal site
There will be 52 spoil disposal sites, total spoils disposed
will be 10726400m3, occupying 121.21hm2.
7.3 Design of retaining wall
On the principle of “Firstly retaining and then discarding and
retaining by grading”, adopt mortar flag stone gravity type
retaining wall protection for spoil ground.
To decrease active earth pressure, inclined type is adopted for
gravity type retaining wall this time. When designed, height of
retaining wall is 4 to 8m. When change occurs on height of wall,
rectigradation transition is adopted for size of wall body; slope
ratio of wall back is 1:0.25; wall surface is paralleled with wall
back. Retaining wall is adopted for retaining base of ballast
slope. Embedded depth of foundation is not lower than 2.0m. The
part below ground of wall body is made into step-form, to increase
stability of wall body; basement is made into reverse slope, to
increase resisting overturning ability of wall body.
φ100 PVC pipe is embedded for retaining wall body and is used as
escape hole, distance is 2m×2m. Intercepting ditch and drainage
ditch is set at ballast top. Bottom part of ditch must be
backfilled densely. Set one settlement joint each 10m
longitudinally for the ditch; width of joint is 2~3cm. For earthy
spoil, filtration bed of crushed stone with width of about 500mm
needs to be set behind wall to facilitate drainage and avoid elapse
of fine soil in earth filling. Set blind drain in the middle of
wall body with bigger height.
7.4 Drainage design
Drainage shall be provided at the top and foot of the disposal
sites in order to timely discharge runoff to avoid soil erosion and
threats to the retaining wall.
7.5 Design of spoil grounds leveling and earth backing
After spoil is completed, top part of spoil ballast should be
leveled. To facilitate recovery of vegetation, mature soil of
certain thickness should be covered onto soil body and buffer top
after leveled; earth backing comes from stripped surface soil of
spoil grounds.
7.6 Reclamation and greening design for spoil grounds
After site leveling and earth backing work is completed for
spoil, through combining local actual situation, adopt reclamation
measure for spoil grounds occupying fallow land for the project and
adopt protection measure of grass planting and shrub planting for
spoil grounds occupying timberland and not using land.
7.7 Design of temporary retaining measure for stripped surface
soil for spoil grounds
For spoil grounds where vegetation recovery is to be made,
before spoil, shovel mature soil by about 0~30cm of surface and
stack them within the scope of spoil grounds without newly
increasing occupied area. Temporary straw bag is adopted for
retaining bottom part of stacked soil. Level and compact surface of
temporary stacked soil, use fabric for covering and build drainage
ditch for temporary soil and make rainfall runoff influx before
make it be successfully discharged into surrounding trench and
other existing drainage system, to avoid causing new soil and water
erosion. After spoil project is completed, level soil body and
buffer, cover stripped surface soil, to facilitate land reclamation
and greening.
Table 15 Site specific management of soil disposal sites
No
Administration
Location
Area(hm2)
Disposal quantity(m3)
Disposal depth(m)
Clearance and leveling (hm2)
Retaining and fencing
Greening
Temporary measures for stripping tops soils
C25 Retaining wall(m3)
C25 Concrete drainage(m3)
Top soils(m3)
Top soils(m3)
Top soils(m3)
Top soils(m3)
Top soils(m3)
Top soils(m3)
Top soils(m3)
Temp. drainage(m3)
Temp settling tank(Nr)
1
Huai’an, Dukoubao, Caijiantan
CK52+100left60m
2.00
150223
7.51
2.00
257
172
5000
14000
6000
227
227
3178
2400
0
0
2
Xinghe, Chengguan, Qinjiaaocun
CK77+750left400m
5.33
306181
5.74
5.33
606
404
13333
37333
16000
650
650
9100
6400
357
3
3
Xinghe, Chengguan, Qinjiaaocun
CK82+200left1500m
2.00
153091
7.65
2.00
262
175
5000
14000
6000
227
227
3178
2400
131
1
4
Xinghe, Chengguan, Qinjiaaocun
CK83+100left100m
2.00
102060
5.10
2.00
198
132
5000
14000
6000
227
227
3178
2400
131
1
5
Xinghe, Chengguan, yangpocun
CK85+300 right 300m
2.00
153091
7.65
2.00
262
175
5000
14000
6000
227
227
3178
2400
131
1
6
Xinghe, Chengguan, yangpocun
CK88+600 right 300m
6.67
408241
6.12
6.67
1140
760
16667
46667
20000
811
811
11354
8000
446
3
7
Xinghe, Chengguan, Qijiacun
CK91+000 right 300m
4.67
255151
5.47
4.67
495
330
11667
32667
14000
584
584
8176
5600
315
2
8
Xinghe, Chengguan, Maqiaocun
CK93+400 right 200m
2.00
159700
7.99
2.00
237
158
5000
14000
6000
227
227
3178
2400
131
1
9
Xinghe, Chengguan, Haoqiancun
CK99+200 right 800m
5.33
425601
7.98
5.33
724
483
13333
37333
16000
636
636
8904
6400
354
3
10
Xinghe, Chengguan, Dongshihaocun
CK103+400 right 200m
6.67
532600
7.99
6.67
257
172
16667
46667
20000
811
811
11354
8000
446
3
11
Xinghe, Chengguan, Dongshihaocun
CK107+500left1500m
2.00
159700
7.99
2.00
267
178
5000
14000
6000
227
227
3178
2400
131
1
12
Zhuozi, Shibat