Top Banner
By Genconnex ® PROPANE / NATURAL GAS Kit for HONDA EU2200i Minimum single 20lbs propane tank for operation at >25deg F. Tank size must be increased for lower operating temperatures at continuous max loads. Approximate 20hrs run time for typical home load in ECO mode on single 20lb tank. No drilling or cutting - 100% reversible (propane tank and generator not included) Power for days not hours! Everything fits safely inside! Genconnex ® Deployable Emergency & Remote Power 1-800-341-0792 3 year warranty Genconnex ® see website for details GenconnexDirect.Net Engineered to the next level. Genconnex ® Designed specifically by Genconnex ® for the Honda EU2200i Heat Sump pump Fridge & Freezer Microwave Hall lights TV & Internet RV Power Problem Solved. Keep it Simple a a a a a a No more gasoline! Propane lasts forever & run days not hours! a Propane & Natural Gas (Bi-Fuel) kit for your Honda EU2200i Inverter Generator. Includes a 6’ propane regulator & hose for connecting to a standard 20-100lb BBQ tank. Other hoses are available. See website for details! Got Propane or Natural Gas?
2

ANE / NATURAL PROP GAS Kit HONDAfor EU2200i Got Propane · Honda EU2000i generator in all 50 States. Dual propane regulator hose L5-30 to 3 outputs - 1/4” Aux outlet hose12’ Parallel

Jul 29, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ANE / NATURAL PROP GAS Kit HONDAfor EU2200i Got Propane · Honda EU2000i generator in all 50 States. Dual propane regulator hose L5-30 to 3 outputs - 1/4” Aux outlet hose12’ Parallel

By Genconnex®

PROPANE / NATURAL GAS Kit for HONDA EU2200i

Minimum single 20lbs propane tank for operation at

>25deg F. Tank size must be increased for lower

operating temperatures at continuous max loads.

Approximate 20hrs run time for typical home load

in ECO mode on single 20lb tank.

No drilling or cutting - 100% reversible (propane tank and generator not included)

Power for days not hours!Everything fits safely inside!

Genconnex®

Deployable Emergency & Remote Power1-800-341-0792

3 year warrantyGenconnex®

see website for details

GenconnexDirect.Net

Engineered to the next level.Genconnex®

Designed specifically by Genconnex® for the Honda

EU2200i

Heat

Sump pump

Fridge & Freezer

Microwave

Hall lights

TV & Internet

RV Power

Problem Solved.

Keep it Simple

aaaaaa

No more gasoline!Propane lasts forever & run days not hours!

a

Propane & Natural Gas (Bi-Fuel) kit for your

Honda EU2200i Inverter Generator. Includes a

6’ propane regulator & hose for connecting to

a standard 20-100lb BBQ tank. Other hoses

are available. See website for details!

Got Propaneor Natural Gas?

Page 2: ANE / NATURAL PROP GAS Kit HONDAfor EU2200i Got Propane · Honda EU2000i generator in all 50 States. Dual propane regulator hose L5-30 to 3 outputs - 1/4” Aux outlet hose12’ Parallel

70-1017r1.1

EVERYTHING FITS SAFELY INSIDE!We engineer our gas systems pre-set for optimum operation with everything safely shock

mounted inside. Ice, snow and dirt can shut external drilled-on kits down while we keep running.

NO ADJUSTMENTS - Just install and run! Propane: 2200 Watts Peak, 1800 Watts >1/2hr Nat. gas: 1800 Watts Peak, 1800 Watts >1/2hr

What’s in this kit? Pre-tested propane demand regulator module pre-tuned (no adjustment necessary) carburetor adapter w/fuel nozzle insert, pre-cut internal propane hose, internal grounding strap, replacement carb bolts, gasoline feed & drain caps, labels, quick-disconnect propane tank hose w/dust covers, 6’ Propane hose w/regulator and full color assembly instructions.

Comes with many hose options including 6’ regulator/hose for 20-60lb

BBQ tank (Other hose options available see website for details)

Propane Nat. Gas Load 1.60 lbs/hr at 38,000BTU 1600 Watts 0.92 lbs/hr at 20,000BTU 800 Watts 0.70 lbs/hr at 15,000BTU 400 Watts

Genconnex® Honda EU2200i Propane & Natural Gas Conversion Kit

What sets us apart? All Genconnex® products are made exclusively with custom stainless steel and aluminum structural components, use all stainless steel locking fasteners for vibration resistance, and all gas line components are brass to resist corrosion and fatigue (as seen often with plastic fittings). No cutting or drilling required. This kit is EPA certified for installation and use in the Honda EU2000i generator in all 50 States.

Dual propane regulator hose

L5-30 to 3 outputs

12’ - 1/4” Aux outlet hose

Parallel cables

Honda cover

N-G Bonding plug

ACME to POL

A FEW OF OUR MANY ACCESSORIES

6’ SS braided gas extension hose

Generator & propane tanknot included

Model: GXK LP-EU2200i-kit-EC

Genconnex®

Deployable Emergency & Remote Power1-800-341-0792

3 year warrantyGenconnex®

see website for details

GenconnexDirect.Net

35 Pond Park Road, Unit 11 Hingham, MA 02043 Genconnex® and Genconnex®Direct are trademarks of New England Gen-Connect LLC. All rights reserved.

GenconnexDirect.Net

Pre-wired for easy electrician installation - all extra parts included to keep install costs down!(you supply wire from outdoor plug to panel, and 30Amp circuit breaker for your particular main panel - everything else included)

6-circuit auto load-shed home transfer switch

(mount next to your main electrical panel)

120Vac, 30Amp watertight house inlet kit

(Hubbell shipboard series L5-30 locking inlet) 30A/120Vac UL 1008 listed transfer switch (conforms to NEC 702.11(B))

Auto load-shedding is fully programmable (each circuit can be individually controlled) Programmable for UPS backup (battery back up critical loads) Designed by APC for Honda Power

20”H x 16”W x 4”D

FEATURES

You don’t have to head to the basement in the dark - the transfer switch automatically powers your selected circuits after your generator starts!

You don’t have to be home - a neighbor or family member can simply plug it in and turn it on with no home entry needed.

More loads from a single 120Vac generator with automatic load shedding! Just program each load for max acceptable off time and minimum acceptable on time and it will turn off loads to make room for larger loads like intermittent microwave use and fan or pump motors starting.

UPS Backup - Just plug in a battery based UPS into the front UPS inlet and select which circuits you want powered while you plug in your generator.

BENEFITS

APC 6 Circuit 120Vac Smart-Home Transfer Switch