Top Banner

of 12

ANALISIS-IODIMETRY2

Apr 08, 2018

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • 8/7/2019 ANALISIS-IODIMETRY2

    1/12

    Serenity Nerds 2010

    IODIMETRY

  • 8/7/2019 ANALISIS-IODIMETRY2

    2/12

    The Members

    Definition of

    Iodimetry

    How to MakeI2 Solution

    Standardization of I2

    Conclusion

    References

    To get started, click the category

    Featured Items

    Album Photos

    Supported By

    Serenity Nerds 11-6

  • 8/7/2019 ANALISIS-IODIMETRY2

    3/12

    The Members

    Serenity Nerds

    20. Raden Achmad H.K

    21. Rania Fardyani

    22. Rima Amalia 23. Siti Aisyah

    I

    D

    M

    TRY

    O

    I

    E

    Definition of

    Iodimetry

    How to MakeI2 Solution

    Standarization of I2

    Conclusion

    References

    19. NurWulan Fiany

  • 8/7/2019 ANALISIS-IODIMETRY2

    4/12

    Definition of

    Iodimetry

    D

    E

    F

    I

    N

    I

    TI

    O

    NP

    R

    I

    NC

    I

    P

    E

    Serenity Nerds

    WHATIS IODIMETRY?

    Iodimetry is one of red-ox titration

    method that oxidizes compound when

    the reagent and the sample react.

    This method is a direct titration because

    the sample directly reacts with theiodine (I2).

    KMnO4 I2

    Oxidator

    I- Fe2+

    Reductor

    How to MakeI2 Solution

    Standarization of I2

    Conclusion

    References

    The Members The sample will react directly with iod

    solution, and then the rest of iod will

    be titrated by Sodium Tio Sulphate

    In this case, we use starch as the

    indicator because the end-point was

    not clear without it.

    End-point without starch to

    End-point with starch fromblue to

    colorless

    slightly yellow

    PRINCIPE

  • 8/7/2019 ANALISIS-IODIMETRY2

    5/12

    E

    X

    P

    L

    A

    N

    A

    TI

    O

    N

    Serenity Nerds

    20g of KI p.a 30-40ml of water

    E.A 1L

    1.27g of iod p.ashaked

    Do not weigh iodinewith

    analytical balance,

    becauseiodinewill

    condense quicklywhen

    interactswith air!

    CovertheErlenmeyer

    immediatelyto minimize

    airtoErlenmeyer!

    PuttheIodium indark bottle

    to prevent HIO

    decomposition bylightsun.

    How to MakeI2 Solution

    P

    R

    O

    C

    E

    DU

    R

    E

    TheadditionofKIisto

    increasesolubilityinwater

    anddecreaseevaporation

    ofiodium

    Standarization of I2

    Conclusion

    References

    The Members

    Definition of

    Iodimetry

  • 8/7/2019 ANALISIS-IODIMETRY2

    6/12

    Standarization of I2

    As2O3

    Serenity Nerds

    PRINCIP

    EIn neutral condition, As2O3 are oxidized by I2. Reaction thathappened is reversible but can be moved to right. HI thatformed as soon as possible is taken from addition of NaHCO3.End-point are obtained from colorless becomes blue with starch

    indicator.

    REACTIO

    NAs2O3 + 2H2O + 2I2 4HI + As2O5HI + NaHCO3

    NaI + CO2 + H2O

    PROCED

    URE

    1g ofAs2O3 V.F 250ml

    Conclusion

    References

    The Members

    Definition of

    Iodimetry

    How to MakeI2 Solution

    PP

    10ml of

    NaOH 4N

    3g of

    NaHCO3H2SO4

    10ml

    starch

  • 8/7/2019 ANALISIS-IODIMETRY2

    7/12

    PRINCIP

    EI2 are oxidized by Na2S2O3until the solution becomes slightlyyellow. The titration stopped and starch added into solution.The titration continued until the solution becomes colorless asthe end-point.

    REACTIO

    NI2 + Na2S2O3 2NaI + Na2S4O6

    PROCED

    URES

    E 250ml

    25ml of I2

    andarization of I2

    As2O3

    Na2S2O

    3

    Conclusion

    References

    The Members

    Definition of

    Iodimetry

    How to MakeI2 Solution

  • 8/7/2019 ANALISIS-IODIMETRY2

    8/12

    Serenity Nerds

    Iodimetry isoneofred-ox

    titration methodthatoxidizes

    compoundwhenthereagentandthesamplereact.

    This methodisa directtitration

    becausethesample directly

    reacts with theiodine (I2).

    I2 can bestandarizedwith using

    As2O3 and Na2S2O3

    I2 solutionwas made bydilutteI2p.a. In KI becausevapor

    pressureI2 in KIissmallerthan

    I2 inwater

    How to MakeI2 Solution

    Standarization of I2

    References

    The Members

    Conclusion

    Definition of

    Iodimetry?

  • 8/7/2019 ANALISIS-IODIMETRY2

    9/12

    Serenity Nerds

    J.Bassett, dkk. 1994. Buku Ajar Vogel,

    Kimia Analisis Kuantitatif Kimia.

    Jakarta : EGCSulistiowati, dkk. 2009. Analisis Volumetri.

    Bogor: Departemen Perindustrian

    Pusdiklat Indistri SMAKBO

    Oxford University. 2005. Oxford Learners

    Pocket Dictionary. China : Oxford

    University Pressen.wikipedia.org

    www,google.com

    www.ecplaza.net

    How to MakeI2 Solution

    Standarization of I2

    The Members

    Definition of

    Iodimetry

    References

    Conclusion

  • 8/7/2019 ANALISIS-IODIMETRY2

    10/12

  • 8/7/2019 ANALISIS-IODIMETRY2

    11/12

  • 8/7/2019 ANALISIS-IODIMETRY2

    12/12