8/7/2019 ANALISIS-IODIMETRY2
1/12
Serenity Nerds 2010
IODIMETRY
8/7/2019 ANALISIS-IODIMETRY2
2/12
The Members
Definition of
Iodimetry
How to MakeI2 Solution
Standardization of I2
Conclusion
References
To get started, click the category
Featured Items
Album Photos
Supported By
Serenity Nerds 11-6
8/7/2019 ANALISIS-IODIMETRY2
3/12
The Members
Serenity Nerds
20. Raden Achmad H.K
21. Rania Fardyani
22. Rima Amalia 23. Siti Aisyah
I
D
M
TRY
O
I
E
Definition of
Iodimetry
How to MakeI2 Solution
Standarization of I2
Conclusion
References
19. NurWulan Fiany
8/7/2019 ANALISIS-IODIMETRY2
4/12
Definition of
Iodimetry
D
E
F
I
N
I
TI
O
NP
R
I
NC
I
P
E
Serenity Nerds
WHATIS IODIMETRY?
Iodimetry is one of red-ox titration
method that oxidizes compound when
the reagent and the sample react.
This method is a direct titration because
the sample directly reacts with theiodine (I2).
KMnO4 I2
Oxidator
I- Fe2+
Reductor
How to MakeI2 Solution
Standarization of I2
Conclusion
References
The Members The sample will react directly with iod
solution, and then the rest of iod will
be titrated by Sodium Tio Sulphate
In this case, we use starch as the
indicator because the end-point was
not clear without it.
End-point without starch to
End-point with starch fromblue to
colorless
slightly yellow
PRINCIPE
8/7/2019 ANALISIS-IODIMETRY2
5/12
E
X
P
L
A
N
A
TI
O
N
Serenity Nerds
20g of KI p.a 30-40ml of water
E.A 1L
1.27g of iod p.ashaked
Do not weigh iodinewith
analytical balance,
becauseiodinewill
condense quicklywhen
interactswith air!
CovertheErlenmeyer
immediatelyto minimize
airtoErlenmeyer!
PuttheIodium indark bottle
to prevent HIO
decomposition bylightsun.
How to MakeI2 Solution
P
R
O
C
E
DU
R
E
TheadditionofKIisto
increasesolubilityinwater
anddecreaseevaporation
ofiodium
Standarization of I2
Conclusion
References
The Members
Definition of
Iodimetry
8/7/2019 ANALISIS-IODIMETRY2
6/12
Standarization of I2
As2O3
Serenity Nerds
PRINCIP
EIn neutral condition, As2O3 are oxidized by I2. Reaction thathappened is reversible but can be moved to right. HI thatformed as soon as possible is taken from addition of NaHCO3.End-point are obtained from colorless becomes blue with starch
indicator.
REACTIO
NAs2O3 + 2H2O + 2I2 4HI + As2O5HI + NaHCO3
NaI + CO2 + H2O
PROCED
URE
1g ofAs2O3 V.F 250ml
Conclusion
References
The Members
Definition of
Iodimetry
How to MakeI2 Solution
PP
10ml of
NaOH 4N
3g of
NaHCO3H2SO4
10ml
starch
8/7/2019 ANALISIS-IODIMETRY2
7/12
PRINCIP
EI2 are oxidized by Na2S2O3until the solution becomes slightlyyellow. The titration stopped and starch added into solution.The titration continued until the solution becomes colorless asthe end-point.
REACTIO
NI2 + Na2S2O3 2NaI + Na2S4O6
PROCED
URES
E 250ml
25ml of I2
andarization of I2
As2O3
Na2S2O
3
Conclusion
References
The Members
Definition of
Iodimetry
How to MakeI2 Solution
8/7/2019 ANALISIS-IODIMETRY2
8/12
Serenity Nerds
Iodimetry isoneofred-ox
titration methodthatoxidizes
compoundwhenthereagentandthesamplereact.
This methodisa directtitration
becausethesample directly
reacts with theiodine (I2).
I2 can bestandarizedwith using
As2O3 and Na2S2O3
I2 solutionwas made bydilutteI2p.a. In KI becausevapor
pressureI2 in KIissmallerthan
I2 inwater
How to MakeI2 Solution
Standarization of I2
References
The Members
Conclusion
Definition of
Iodimetry?
8/7/2019 ANALISIS-IODIMETRY2
9/12
Serenity Nerds
J.Bassett, dkk. 1994. Buku Ajar Vogel,
Kimia Analisis Kuantitatif Kimia.
Jakarta : EGCSulistiowati, dkk. 2009. Analisis Volumetri.
Bogor: Departemen Perindustrian
Pusdiklat Indistri SMAKBO
Oxford University. 2005. Oxford Learners
Pocket Dictionary. China : Oxford
University Pressen.wikipedia.org
www,google.com
www.ecplaza.net
How to MakeI2 Solution
Standarization of I2
The Members
Definition of
Iodimetry
References
Conclusion
8/7/2019 ANALISIS-IODIMETRY2
10/12
8/7/2019 ANALISIS-IODIMETRY2
11/12
8/7/2019 ANALISIS-IODIMETRY2
12/12