SUBMITTED BY BAGGIOJOSE 13MD01 AN INVESTIGATION OF THE FAILURE OF LOW PRESSURE STEAM TURBINE BLADES
May 25, 2015
SUBMITTED BY BAGGIOJOSE13MD01
AN INVESTIGATION OF THE FAILURE OF LOW PRESSURE
STEAM TURBINE BLADES
CONTENTS
1. INTRODUCTION2. DESCRIPTION3. TESTS & RESULTS4. CONCLUSION5. REFERANCE
INTRODUCTION
Steam turbine extracts energy from steam3 types HP,IP & LPBlades convert linear to rotary motionDesigned life 30 yearsLP blades are prone to failure
DESCRIPTION
210 MW thermal power plantOverhauled after 5 years shut down after 2
years12% Cr steel with tempered martensiteBrazed joint b/w blade and steel rodeStriations & bleach marksFluctuation of loading
ACTUAL BLADE
POSSIBLE CAUSES
Mateial defectsImproper brazing operationsImproper plant operations
TESTS & RESULTS
Visual inspection
Brazed joints disjointedCracks from holesBlack scale(magnetite)
Contd…
Scanning electron microscope
Microstructure studyMartensitic for bladeBianitic structure for rod
BLADE
ROD
Contd…
Chemical analysisComposition as per AISI 400 series stainless
steel
Contd…
Mechanical propertiesHardness for blade 265 VPNHardness for rods 225 VPNHrdness of brazing wire 200 VPN
Contd…
Contd…
FractographyGalvanic corrosionCrack initiaion at hole and propagation
Contd …
High cycle fatigue test0.7 static 0.5 dyn. 10000 cyc
CONCLUSION
Starts with corrosion of brazed jointsFretting & metal removalCracks from holesFatigue assisted crack growth
COMMENTS
Improper brazingImproper maintenanceImproper opertion
REFERANCE
Fracture analysis case studies 2 D.R.H. Jones
An investigation of the failure of low pressure steam turbine blades N.K Mukhopdhyay, S . Ghosh Chowdhury