Page 1: An introduction to Zeversolar inverters

Introduction of

zeversolar inverters

Page 2: An introduction to Zeversolar inverters

2

Agenda

1. Overview

2. Introduction of Zeversolar String Inverters

3. A Look Inside

4. Technical Information

5. Monitoring Solution

6. PMU

7. SolarCloud

8. ZeverPlan

9. What I´ve Seen

10. Manufacturing Tour

Page 3: An introduction to Zeversolar inverters

Overview

3

01

Page 4: An introduction to Zeversolar inverters

Our Product Overview

4

No matter what size your solar plant is we offer the right inverter

Our string inverters range from 1.5kW to 20kW to satisfy residential and commercial usage

* Available expected end of 2014

** Available expected August 2014

*** Available expected end of October 2014

1-3

TL1500

TL2000

TL3000

3-5

TL3680

TL5000

4-6

TLC4000

TLC5000*

TLC6000

TLC8000**

500

NSG-

500K3TL

1000 KW

NSG-

1000K3TL

15-20

TLC10K**

TLC15K

TLC17K

TLC20K

Page 5: An introduction to Zeversolar inverters

Certification

5

UK Certificates can be downloaded from the ENA Register

http://www.ena-eng.org/ProductTypeTestRegister/Login.aspx?LoggedOut=Y

Page 6: An introduction to Zeversolar inverters

Introduction of Zeversolar

String Inverters

6

02

Page 7: An introduction to Zeversolar inverters

Single Phase Inverters

7

Eversol TL

TL1500-20

TL2000-20

TL3000-20

Features:

• Efficiency - > 96,5 %, MPPT - 99,5 %, European - > 96,2 %

• RS485 communication via RJ45 (IP65)

• IP65

• Convection cooled

• Eversol TL – 1 MPPT / Evershine TL – 2 MPPT´s

Introduction of Zeversolar Inverters

Evershine TL

TL3680*

TL5000-10

Page 8: An introduction to Zeversolar inverters

Three Phase Inverters

8

Evershine TLC

TLC4000

TLC5000*

TLC6000

TLC8000**

Features

• Efficiency - 98 %, MPPT - 99,5 %, European - 97,5 %

• Wide voltage range

• Two MPPT´s for flexible PV Plant design

• Graphical LCD-Display

• IP65

Introduction of Zeversolar Inverters

Eversol TLC

TLC10K*

TLC15K

TLC17K

TLC20K

Page 9: An introduction to Zeversolar inverters

A Look Inside

9

03

Page 10: An introduction to Zeversolar inverters

Exploded View

10

Bracket

Heat sink

PCBA

Tank

Lid

Eversol TL

Bracket

Heat sink

PCBA

Tank

Lid

Bracket

Heat sink

PCBA

Tank

Lid

Evershine TLC Eversol TLC

Page 11: An introduction to Zeversolar inverters

Eversol TL

11

直流EMC滤波器DC EMC filter

光伏输入DC input

直流开关DC switch

升压电路BOOST DC/DC

逆变电路DC/AC

交流电抗器AC inductor

EMC滤波器EMC filter

L

N

PE

交流输出AC output

继电器Relay

987654321

Page 12: An introduction to Zeversolar inverters

Technical Information

12

04

Page 13: An introduction to Zeversolar inverters

High Power Generating Capability

13

• High efficiency across all products > 97 %

• High input DC voltage

• PV Array oversizing – 30 %

• Reactive Power Control up to 0.85 lagging / leading

• Wide MPPT voltage range

• Multiple MPPT´s

• East / West design

• Flexible string lengths

MPPT A

MPPT B

Flexibility

Page 14: An introduction to Zeversolar inverters

Did You Know

14

• IP 65 rated enclosure and RJ45 comm ports

• Tolerant to temperature [-25oC – 60oC]

• Heatsink

• Cooling Fan

• 3 kW - up to 10 kg lighter – lowest DC start up voltage – lowest DC shutdown voltage

• 5 kW – up to 7 kg lighter – lowest DC start up voltage – lowest DC shutdown voltage

• 15 kW – 9 kg heavier – not the lightest

• Quality internal components

Page 15: An introduction to Zeversolar inverters

Sunclix DC Connector

15

• No special crimping tool required

• 2.5mm2 – 6mm2

• 40 A CCC – 1100 V

• Terminate cable up to 10 times

Page 16: An introduction to Zeversolar inverters

16

Optimisation of the Product

Development Process

Engineering

Pilot TrialProject Start

Planning &

PreperationR&D Design

Labor Pilot

Trial

Field

Pilot TrialMass

Production

Market Research, Feasibility Assessment

Establishment of Project Team

Review by Technical Experts

Evaluation by SMA

Customer Tests

Page 17: An introduction to Zeversolar inverters

High Reliability

17

• Comprehensive Testing• Zeversolar (internal)

• SMA – 30 years of experience

• Tests include:-• Manual Parametric Test

• Fan control test

• Residual current test

• ISO test ……

• ATE Test

• Environmental Verification Test

• IPXX test

• High&low temperature characteristic evaluation

• High temperature & humidity test, Drop test ……

• Field application test

• Teamwork• Zeversolar and SMA engineers work together

`Testing in accordance

with SMA standards´

Page 18: An introduction to Zeversolar inverters

„All in all, the product, Eversol

TL3000, is operating smoothly and

steadily. We have expectations

that customers will be satisfied

with it.”

--- SMA Test Centre

Feb. 2014

18

Summary

PASSED

Page 19: An introduction to Zeversolar inverters

Monitoring Solution

19

05

Page 20: An introduction to Zeversolar inverters

Overview

20

Data collector

PMU(Power Management Unit):

• Comprehensive data and event collection.

• Upload data to cloud storage, local/remote monitoring via network connection.

• Support power regulation required by BDEW and EEG

PMUSolar Cloud

Zeversolar inverters

RS485

Internet

Monitor interface

Solar Cloud:

URL: http://solarcloud.zeversolar.com/

Page 21: An introduction to Zeversolar inverters

PMU

21

06

Page 22: An introduction to Zeversolar inverters

PMU – Power Management Unit

22

Page 23: An introduction to Zeversolar inverters

PMU web server

23

Page 24: An introduction to Zeversolar inverters

Solarcloud

24

07

Page 25: An introduction to Zeversolar inverters

Solarcloud

25

PC interface Mobile phone interface

Monitoring interface

Solar Cloud:

URL: http://solarcloud.zeversolar.com/

Page 26: An introduction to Zeversolar inverters

ZeverPlan - Demo

26

08

Page 27: An introduction to Zeversolar inverters

ZeverPlan

27

Page 28: An introduction to Zeversolar inverters

28

Page 29: An introduction to Zeversolar inverters

ZeverPlan

29

Page 30: An introduction to Zeversolar inverters

30

Page 31: An introduction to Zeversolar inverters

What I´ve Seen

31

09

Page 32: An introduction to Zeversolar inverters

RCD Nuisance Tripping

32

• Residual Current Device

• Detects leakage current

• Rated @ 30 mA – avoid heart attacks caused from electric shock

X X X X

X

X

X X X X

XX Addition of PV causes

Upstream RCD´s to trip

Some inverters disconnect

after 5s on loss of mains

Back

Connect to supply side of

main RCD

• Zeversolar inverters have an internal Residual Current Monitoring Unit

• We recommend a 120 mA RCD Type A or B

Page 33: An introduction to Zeversolar inverters

High Line Voltage

33

• Typical in rural properties

• Measured line voltages exceeding 250 V

• High irradiance + low load = export power -> voltage rise – inverter trip

255 VExport

• Turn on more load – boil some water in kettle or turn on stove

• Ask DNO to change the taps on Tx to reduce the voltage

Page 34: An introduction to Zeversolar inverters

Oversizing PV Array

34

• Oversize by how much?

• 10 % in areas of high irradiance

• 20 – 30 % in areas of low irradiance

• 3 kW Array Vs 4 kW Array – SB3000TL – 250 W Trina Solar Panels – London

• 3 kW – 2732 kWh/yr Vs 4 kW – 3647 kWh/yr

• Pvsyst 5.54!

Page 35: An introduction to Zeversolar inverters

Manufacturing Tour

Company Information35

10

Page 36: An introduction to Zeversolar inverters

Manufacturing

Capacity

4 string inverter manufacturing

lines and 3 central inverters

manufacturing lines (4 lines by

end of 2014)

1.8GW annual capacity with

full product portfolio

now/2.8GW capacity from end

of 2014

36Company Information

Page 37: An introduction to Zeversolar inverters

String Inverter Tour

Company Information37

PCB Soldering PCB Check

Documentation

Assembly

PackingReady for Shipping

ATE Testing

Age Test

Page 38: An introduction to Zeversolar inverters

Central Inverter Tour

Company Information38

Assembly Line Front Assembly

Ready for ShipmentContainerised 1 MW Age Test

Front Assembly Rear Assembly Rear Assembly

Page 39: An introduction to Zeversolar inverters

39

Thank you.

Energy for everybody.

Kaiserswerther Str. 115 | 40880 Ratingen Deutschland

Tel.: +49 2102 420 000 | Fax.: +49 2102 420 001

www.zeversolar.com