An Approach to Heat Recovery An Approach to Heat Recovery in Rural Alaska in Rural Alaska Introduction Introduction Background – Maintenance & Background – Maintenance & Repair Repair Small Scale: 50 kW to 3500 kW Small Scale: 50 kW to 3500 kW Heat Recovery: Heat Recovery: SAVES Fuel - NOT SAVES Fuel - NOT Primary Heat Primary Heat Keep it SIMPLE Keep it SIMPLE
29
Embed
An Approach to Heat Recovery in Rural Alaska Introduction Introduction Background – Maintenance & Repair Background – Maintenance & Repair Small Scale:
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
An Approach to Heat RecoveryAn Approach to Heat Recovery in Rural Alaska in Rural Alaska
IntroductionIntroduction Background – Maintenance & RepairBackground – Maintenance & Repair Small Scale: 50 kW to 3500 kWSmall Scale: 50 kW to 3500 kW Heat Recovery: Heat Recovery: SAVES Fuel - NOT Primary SAVES Fuel - NOT Primary
HeatHeat
Keep it SIMPLEKeep it SIMPLE
Rules of ThumbRules of Thumb
1/3 Electricity : 1/3 Jacket Water : 1/3 Exhaust1/3 Electricity : 1/3 Jacket Water : 1/3 Exhaust 2000 BTU/kW-Hr (jacket water)2000 BTU/kW-Hr (jacket water) 100,000 BTU delivered Heat = 1 gallon #1 Diesel100,000 BTU delivered Heat = 1 gallon #1 Diesel 0.3 x Power Plant Annual Fuel Use x 0.60.3 x Power Plant Annual Fuel Use x 0.6 Pumping Energy Costs <= 10% Fuel ValuePumping Energy Costs <= 10% Fuel Value Size System Flow for 2/3rds Peak LoadSize System Flow for 2/3rds Peak Load
End-UsersEnd-Users
Water Plant / WasheteriaWater Plant / Washeteria SchoolsSchools Public Facilities (Clinics, City Offices, Rec Public Facilities (Clinics, City Offices, Rec
Air ControlAir Control– Air Eliminator (rol-air-trol vs. air scoop)Air Eliminator (rol-air-trol vs. air scoop)– Expansion Tank Sizing (40F or –40F)Expansion Tank Sizing (40F or –40F)
Pre-charge (set for specific application) Pre-charge (set for specific application)
Arctic Piping Loop FluidArctic Piping Loop Fluid– Ethylene / Propylene / Water Ethylene / Propylene / Water