Top Banner
Ammonia Emergency Response Training For NIEHS TRX Attendees
56

Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

May 14, 2018

Download

Documents

ngokhuong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Emergency Response Training

ForNIEHS TRX Attendees

Page 2: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Midwest ConsortiumCarol Rice -Director

Lakeshore Technical CollegeCleveland, WIRich Hoerth – Dean of Public Safety

Page 3: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Why are YOU here?

A. I thought my boss would be in another session.B. Sounded like the best chance to napC. I’ve failed to find a good hiding place, yet!D. My boss IS here!

(That’s why I’m here, I’d rather be site-seeing)

Page 4: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Wayne’s Goal for TodayDetermine who is physically fit to lead a Level A response to a simulated ammonia leak.

(Was this misrepresented in the description?)

Page 5: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Outer glovesinner glovesboots with steel toe (per hazards)hard hat - opt.Disposable over suit

Page 6: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 7: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Or, how about:

Discussion on how LTC presents Ammonia ER with an interactive discussion on ways to improve it AND apply it “back home”

Page 8: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

24 Hour Technician Level –Ammonia Emergency ResponseTechnician competencies relating to ammonia.

(Local OSHA (Wisconsin) OK with content and format)

Emergency Response Plan must reflect the “ammonia only” response

Page 9: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

FOCUS

Refrigeration facilities

Other marketsProducersManufacturingAgriculture Power plantsHazMat Teams – Public & Private

Page 10: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Potential Clients

Food processors

Dairy industry

Cold storage

Page 11: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Look for these

Page 12: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Condenser

Page 13: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Students

Refrigeration techniciansMaintenance employeesSupervisorsAssociatesEngineers (NOT real people but they count for NIEHS purposes)

Page 14: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

LTC’s Outline

Page 15: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

DAY 1

45 min - Introduction and WelcomeWhy are we here?PaperworkHAZWOPER-29CFR1910.120Technician competencies

30 min - Hazard Recognition(Chemistry)Chemical and physical characteristics of ammonia

Page 16: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

30 min - Hazard Recognition for AmmoniaPlacards and labelsContainersMSDSLiterature and resourcesHaz Rec Exercise

45 min - Health Hazard RecognitionAmmonia Toxicology

30 min - Medical ConcernsMedical surveillanceHeat stress and field monitoring

Page 17: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

60 min - Air MonitoringLEL/OxygenElectrochemical sensorsMetal oxide sensorsPhotoionizationColorimetric tubesBadgesWhat’s`new

60 min - Air Monitoring Lab

Page 18: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

70 min - Respiratory ProtectionOSHA Standard - 1910.134Air Purifying Respirators (APRs)Supplied Air Respirators (SARs)Self-contained Breathing Apparatus (SCBA)Escape units

90 min - Respiratory Protection Workshop

SCBAAir linesAPRs and fit testing

Page 19: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

DAY 2

60 min - Personal Protective EquipmentLevels of protectionSelection of PPEExercise

120 min - PPE WorkshopDressout in Levels D,C,B,&A

Page 20: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

40 min - DecontaminationDecon plan

LineWork zones

20 min - Work PracticesPhysical hazardsSOPsConfined spacesLockout/tagout

30 min - Refrigeration Systems

Page 21: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

60 min - Controlling Ammonia ReleasesTechnologies and techniquesVideo(s) and critique

130 min - Round-Robin ExerciseRepairing a leak in Level ADeconDebriefing

Page 22: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

DAY 3

150 min - Emergency ResponseSARA- federal,state, and local responseEmergency response plansIncident command system (ICS)Response operations

size-upstrategy/tacticsentrytermination

Page 23: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

90 min - Emergency Response Tabletop Exercise90 min - Simulation of an Ammonia Leak

Team organizationSize-upEntryControlDeconTermination/Critique

60 min - Final Exam

Page 24: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

90 min - Simulated Ammonia Incident -B

ResponseTermination

Course Closing

Page 25: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Any memorable experiences with ammonia?

That I won’t have to report to the authorities

What is 50 ppm, OSHA’s PEL, like?

Page 26: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Monitoring

Page 27: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Typical ER real time monitors

4 gas – without an ammonia cellEC ammonia specificMOS – non-specificPID/FIDColorimetric tube

ChipBadge

TWA

Page 28: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Monitoring Lab

HO

Page 29: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

PPE

Page 30: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Content

Respiratory Protection

CPCLevels of Protection

Ammonia is one of a few (?) chemicals that OSHA reports a Level B to Level A requirement for: 5000 ppm

Video on LOP and CPCSelection exercise

Page 31: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

How many want to do a Level B dressoutexercise now?How many want to watch?

Page 32: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Practical Applications

All over the board

Factors Affecting Response Levels:WhoCompany’s safety environmentTraining $$$$$$

Page 33: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Decon

Page 34: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Wet vs dry vs none stories Water vs fan (Wayne’s World)

Page 35: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Videos

Page 36: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Wayne’s favorite

“Valuable Lessons Learned Regarding Anhydrous Ammonia”

Satellite teleconference – 2 hr12/5/90

Hands-on with live ammonia

Page 37: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Others

Anhydrous Ammonia Emergency Film Group (1994)fair

Page 38: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Safety – Emergency Response Procedures

International Institute of Ammonia Refrigeration – IIAR

Good , but not for ER, rather EAP

They have a series of videos I have not seen

Page 39: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

PPEDecon

Elaborate - howShaving cream – why

IC

Page 40: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

OthersPhillip’s 1960sRussian firefighters

Page 41: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Table Top Exercise

HO

Page 42: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ammonia Exercises

Page 43: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Ideas

Engine room - realisticNoiseHazards

Page 44: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 45: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 46: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 47: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 48: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Empty rooms/garagesAmmonia “rack”

Semi TrailersSmokeAccess

Page 49: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 50: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 51: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 52: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...
Page 53: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

WARNING

Don’t get caught in a PSM clusterDiagrams have mistakes and are not current (despite what the client says)

Page 54: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Resources

Page 55: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Clients or potential clientsRefrigeration contractorsAmmonia producers/suppliersIIAR

Page 56: Ammonia Emergency Response Training · Refrigeration – IIAR Good , but not for ER, rather EAP They have a series of videos I have not seen ...

Q&A