IntroAPQP/PPAPWORKBOOK V4.0
Interplex Part NumberVAL-5061-000Customer NameValeo
SilvaniaDivisionQueretaroPart Name (description)Bulb holder NH F25
Applique.Customer Part Number71A-1807-0001Engineering Change
Level5AEngineering Change Level Date7Drawing
Number71A-1807-0001Application9Customer Conctact10e-mail1112Drawing
Reception Date13Submission Date14Supplier NameInterplex,
MxicoSupplier Code16Street
Address17City18State19Zip20Country21Phone Number22Fax
Number23Preparado por:Victor HerreraCore teamF. Martinez, L.
Miranda, S. Guzmn, O. Galindo, R. VenturaTitle26e-mail2728Raw
Material29Raw Material Dimensions30Plating31Material
Supplier32IMDS33PPAP34Flow diagram35PFMEA36Control Plan37
Diagrama de ProcesosDIAGRAMA DE FLUJO DE PROCESO(PROCESS
FLOWCHART)
Cliente:Valeo SilvaniaNo. parte:No. parte
IXM:VAL-5061-000(Customer)Bulb holder NH F25 Applique.(Costumer
part number)(IXM part number.)Descripcin:Nivel de Rev. de
dibujo.6BRevisin y fecha:18/06/2014(description)(ECL)(Rev. and date
Flowchart)Elaborado por: Mitchell Ascenci, Ramirez Vavarro, Ramirez
Plascencia, Minerva Valle(Prepared by)
Smbologa
(legend):OperacinTransporteInspeccinDemoraAlmacenaje(operation)(transportation)(inspection)(delay)(storage)Operation
or EventOperacin.Descripcion de la operacin.(Operation)(description
of the operation or event)
.Moldeo .Moldeo de parte plasticaSe moldea la parte plastica
(housing)
traslado de partes plasticaSe reciben partes plasticas
provenientes del area de moldeo para primer ensamble
Se estampa parte metalicaSe estampa cinta metalica para crear el
(Spring Clip)
traslado de partes metalicasSe reciben partes metalicas
provenientes del area de estampado para primer ensamble
Acomodo del area de primer ensambleSe acomoda el area donde se
trabajara y se ponen en su lugar la materia prima, para iniciar el
proceso de ensamble
Primer ensamble.Ensamble de housing (VAL-5061-104) con Spring
Clip (VAL-5061-103).
Cortado de housingCorte de rebaba de housing
Inspeccion de housingSe inspecciona el housing que cuente con
los orificios adecuados para el insertado del circuito
primario.
Traslado a segunda estacion, de segundo ensambleSe traslada el
primer ensamble a la segunda estacion para el segundo ensamble
(Housing-Spring Clip con Circuito Primario)
Estampado del circuito primarioSe estampa el circuito primario
en cinta metalica
Segundo ensamble Insertado de circuito (VAL-5061-102) en
housing,Insertado de Centerin Ring H21W (VAL-5061-101) .
Mesa rotatoria Para cortes y pruebas al housing con
circuito.
Inspeccin automatica de componentes plasticos y metalicos.
Verificar que tenga los componentes moldeados y metalicos.
Fundido de postes.Fundido de postes para sostenimiento de
componentes.
Corte de pistas.Separar las pistas en el circuito.
Prueba de alto voltajeVerificar presencia de componentes
metlicos y circuitos abiertos.
Marcado Marcado de piezas Ok,
Descarga de piezas No Ok Descarga de piezas No Ok,
Descarga de piezas Ok, Descarga de piezas Ok,
Inspeccin visual.Verificar presencia de componentes metlicos y
circuitos abiertos.
Retrabajo de piezaSi al inspeccionar salio un rebaba plastica o
con filo los bordes, se eliminan retrabajandolo con un bisturi.
Liberacin de producto.Inspeccin final del ensamble acorde a
criterios de ayuda visual.
Empaque.Empaque de producto y envo del material a almacn.
AlmacenSe trasladan las piezas empacadas a almacen
IXFC073.06
Hoja1
AMEFANALISIS POTENCIAL DE MODO Y EFECTO DE FALLA DE PROCESO
(POTENTIAL PROCESS FAILURE MODE AND EFFECT ANALYSIS) No. Referencia
:VAL-5061-000(Supplier P/N):
N/P Cliente:71A-1807-0001Responsabilidad del ProcesoInterplex
MxicoPreparado por:Set Guzman(Customer P/N)(process
responsibility)(Prepared by)
Revision de Cliente:5AKey Date9-Feb-10Fecha
Original:9-Feb-10(Customer Revision):(key date)(orig. date)
Equipo Resp:Revisin y fecha: (Rev 4) 18/06/2014(Core Team)F.
Martinez, L. Miranda, S. Guzmn, O. Galindo, R. Ventura(rev. and
date)ProcesoProcessStep
Funcin FunctionRequerimientosRequirementsModo de Falla Potencial
Potential failure modeEfecto(s) Potenciales de la FallaPotential
effect(s) of failureSeveridad (Severity)Clase
(Classification)Causa(s) potenciales / mecanismo(s) de Falla
Potential cause(s) / mechanism(s) of failureOcurrencia
(Ocurrence)Controles de Proceso Actuales, (P) Prevencion (D)
Deteccion Current process controls: P - Preventive, D -
DetectionDeteccin (Detection)R. P. N.Accin(es) Recomendad(as)
Recommended action(s)Responsable y Fecha Objetivo de Cierre
Responsibility & target completion dateResultados de la Accin
Action resultsAccciones Tomadas Actions takenS e vO c cD e t R. P.
N.Primer ensamble.First assembly.10Componentes de ensamble.assembly
components.Falta de componente en housing (VAL-5061-100)Missing
components (VAL-5061-100)8El componente no es colocado.The
component is not positioned.4Sistema de vision Vision systeam264N /
AN / AN / AFalta de terminal en housing (TER:0002)Missing terminal
(TER: 0002)Falta de continuidad entre componentes.Lack of
continuity of between components.8El componente no es colocado.The
component is not positioned.4Prueba de Hipot para detectar
presencia de componentes metalicos.Hipot test to detect the
presence of metal components.264N / AN / AN / AFalta de terminal en
housing, (VAL-5061-103)Missing terminal (VAL-5061-103)8El
componente no es colocado.The component is not positioned.4Prueba
de Hipot para detectar presencia de componentes metalicos.Hipot
test to detect the presence of metal components.264N / AN / AN /
AEnsamble incorrectoincorrect assembly8Desconocimiento del
asociado.Lack of knowledge of the partner.3Se cuenta con instruccin
de trabajo para colocacin de componentes, IXIT115.It has to work
instruction component placement, IXIT115.372N / AN / AN / ASegundo
ensamble, circuito en housing.Second assembly, circuit
housing.20Componentes de ensamble.assembly components.Falta de
componente VAL-5061-102Missing component, VAL-5061-102falta de
continuidad entre componentes.Lack of continuity of between
components.8El componente no es colocado.The component is not
positioned.3Instruccin de trabajo para insertado de componente,
IXIT116.Statement of Work for component inserted, IXIT116.372N / AN
/ AN / AEl equipo cuenta con una prensa para llegar la terminal a
fondo del housing y detectar falta de componenete.The equipment has
a press to get the terminal to detect bottom of the housing and
lack of componente.248N / AN / AN / AEnsamble incorrectoWrong
assembleMaterial de desperdicio en la linea.Wastage material in the
line.8El componente no es colocado adecuadamente.The component is
not properly positioned.2Instruccin de trabajo para insertado de
componente, IXIT116.Statement of Work for component inserted,
IXIT116.464N / AN / AN / AFalta de componente centering Ring W16W
(VAL-5061-100) en housing.Missing centering component W16W Ring
(VAL-5061-100) in housing.Ensamble inapropiado del foco o
intermitencia en el buld holder.Improper assembly or intermittency
focus buld holder.8El componente no es colocado.The component is
not positioned.3Instruccin de trabajo y capacitacion del operador
para correcta colocacion de componenetes con la IXIT117Work
Instruction and training of the operator for correct placement of
the IXIT117 componentes248N / AN / AN / AFalta de componente
centering Ring H21W (VAL-5061-101) en housing.Missing centering
component Ring H21W (VAL-5061-101) in housing.Ensamble inapropiado
del foco o intermitencia en el buld holder.Improper assembly or
intermittency focus buld holder.8El componente no es colocado.The
component is not positioned.3Instruccin de trabajo y capacitacion
del operador para correcta colocacion de componenetes con la
IXIT117Work Instruction and training of the operator for correct
placement of the IXIT117 componenetes248N / AN / AN / AInspeccin
automatica de componentes plasticos.Automatic inspection of plastic
components.30.1Componentes de ensamble.assembly components.Falta de
componentes plasticos no detectados, (Centering Ring H21W
(VAL-5061-101) y Centering Ring W16W (VAL-5061-100) en el
housing.Missing undetected plastic components, (Centering Ring H21W
(VAL-5061-101) and Centering Ring W16W (VAL-5061-100) in the
housing.Ensamble inapropiado del foco o intermitencia en el buld
holder.Improper assembly or intermittency focus buld
holder.8Sensores desalineados en el equipo.Sensors misaligned on
the equipment..3Sensores atornillados en el equipo de
prueba.Sensors screwed into the test equipment.372N / AN / AN /
ADummies para verificar el funcionamiento del sensor.Dummies to
verify sensor operation.372N / AN / AN / AFundido de postes.Heat
staking.30.2Fundido muy delgado y extendidoHeat stake thin and wide
spreadIntermitencia de corriente en ensamble final y conector del
vehiculoCurrent intermitance in final assembly and with vehicle
connector8Temperatura inadecuada de operacinInadequate operation
temperature2Validacion de set-up IXFC172B, Inspeccion visual del
producto terminado, prueba de push test.Validation of set-up
IXFC172B, Visual inspection of the finished product, push test
test.464N / AN / AN / APuesta a punto de la linea con los parmetros
pre-establecidos.Setup of the line with the pre-set
parametersAltura incorrecta de Pines de cabezal (Transmisor de
calor)Incorrect pins heigth (heat transmission)264N / AN / AN /
APostes sin fundirPlastic posts with no heat stakeCircuito
levantado no hace buen contactoCircuit lifted, poor contact7Altura
incorrecta de Pines de cabezal (Transmisor de calor)Incorrect pins
heigth (heat transmission)256N / AN / AN / AFractura en el
housing.Breaking into the housing.Pieza no funcional en el ensamble
final.Non functional part in the final assembly.8Estrs de
componente en la estacion de Heat staking.Stress component in the
Heat staking station.4Validacion de set-up IXFC172B, Inspeccion
visual del producto terminado, prueba de push test.Validation of
set-up IXFC172B, Visual inspection of the finished product, push
test test.4128Controlar el flujo de aire del planchado por medio
del regulador.Set Guzman10-Oct-13Se incluyo regulador de flujo de
aire en la linea y se agrego su verificacion en la hoja de arranque
IXFC172B82464Ajustar las alturas de los postes del heat stakes en
la herramienta Set Guzman10-Oct-13Se ajustaron las alturas de
postes del heat stake documentado en el formato de arranque
IXFC172B pag. 2Corte de pistas.Cutting of tracks
(Trimming).30.3Puesta a punto de la linea con los parmetros
pre-establecidos.Setup of the line with the pre-set
parametersCircuito con uniones sin cortar.Circuit with not
trimming.Corto circuito.Electric short circuit.8Ausencia de
cortadores.No cutting punches.2Se verifica que la parte cuente con
los cortes en sus areas y se registra en IXFC172B.(setup), rueba de
alto voltajeIt verifies that the part has the cuts in their areas
and recorded in IXFC172B, Hipot test232N / AN / AN / ATamao de
ponzones inapropiado.Size of punchs inappropriate.2No hay.We dont
have696Entregar el libro de la herramienta a tallerA.
Rubio31-May-13Por realizar.Documentar las incidencias de la
herramienta en el libroA. Alvarado.14-Jun-13Por realizar.El
conector no funciona apropiadamente.The connector does not work
properly.8Punzones de corte desafilados.Punchs worn
out.2Mantenimiento preventivo de la herramienta IXFC067, acorde a
la cantidad de golpes determinados.Preventive maintenance IXFC067
tool, according to the number of strokes determined.348Documentar
las incidencias de la herramienta en el libroA.
Alvarado.14-Jun-13Por realizar.8Manejo inadecuado de piezas
rechazadasIncorrect handling of rejected pieces3(P) Contenedor de
scrap cerrado (D) Equipo automatico separa piezas rechazadas en
prueba electica, disposicion de material no conforme acorde a
IXPC13B, Inspeccin de scrap acorde a criterios de ayuda visual,
IXAV11.(P) scrap container closed (D) automatic equipment under
test separates Electica rejected parts, disposition of
nonconforming material according to IXPC13B, scrap inspection
criteria according to visual aid, IXAV11248Hacer aestudio de
tiempos y retorno de invercin.F. Martinez5-Jun-13Por realizar.Diseo
e instalacion de componentes.A. Rubio5-Julio-13Por
realizar.Instalacion de programa y programacin del equipo.S.
Guzman12-Julio-13Por realizar.Prueba de alto voltajeElectrical
Test.30.4Puesta a punto de la linea con los parmetros
pre-establecidos.Setup of the line with the pre-set parametersFalla
en evaluacion (aceptar piezas rechazadas)Failure of testing process
(accept defective parts)No enciende focoBulb does not ligth
8Parametros de Setup incorrectosInadequate set-up
parameters3Validacion de set-up formato IXFC172B, Piezas dummies
para Hi-pot.Validation of IXFC172B format set-up, Pieces dummies
for Hi-pot.248N / AN / AN / A8Equipo apagadoEquipment turned off2
Hoja de parametros para Hi-pot, IXHPAR96.Sheet parameters for
Hi-pot, IXHPAR96.232N / AN / AN / A8Falta de pogo-pinesMissing
pogo-pins2Verificacin y cambion de partes acorde a
IXIT170.Verification and change of parts according to IXIT170.232N
/ AN / AN / ACorto circuito y / o falta de componentes.Short
circuit and / or missing components.8Parametros de Setup
incorrectosInadequate set-up parameters3Validacion de set-up
formato IXFC172B, Piezas dummies para Hi-pot.Validation of IXFC172B
format set-up, Pieces dummies for Hi-pot.248N / AN / AN / A8Equipo
apagadoEquipment turned off2 Hoja de parametros para Hi-pot,
IXHPAR96.Sheet parameters for Hi-pot, IXHPAR96.232N / AN / AN /
A8Falta de pogo-pinesMissing pogo-pins2Verificacin y cambion de
partes acorde a IXIT170.Verification and change of parts according
to IXIT170.232N / AN / AN / A Marcado Marked 30.5Marcado
MarkedPieza sin punto de marcado Part without marking
pointTrasabilidad Traceability5Regulador bloqueado blocked
Regulator3Sensor de final e inicio Sensor end and beginning230N /
AN / AN / A5Dao en los actuadores Damage to the actuator3Sensor de
final e inicio Sensor end and beginning230N / AN / AN / A Descarga
de piezas No Ok, No Ok Parts Download 30.5.1Descarga de piezas No
Ok, No Ok Parts Download La Pieza no se descarga The part is not
downloadedPieza no funcional en el ensamble final.Non functional
part in the final assembly.5Dao en los actuadores Damage to the
actuator3Sensor de final e inicio Sensor end and beginning230N / AN
/ AN / A Descarga de piezas Ok, Ok Parts Download 30.6Descarga de
piezas Ok, Ok Parts DownloadLa Pieza no se descarga The part is not
downloadedLa pieza se retrabaja The piece is reworked5Dao en los
actuadores Damage to the actuator3Sensor de final e inicio Sensor
end and beginning230N / AN / AN / AInspeccin visual.Visual
inspection.40Puesta a punto de la linea con los parmetros
pre-establecidos.Setup of the line with the pre-set
parametersDimensiones criticas fuera de especificacionCritical
dimensions out of toleranceNo ensamblaCan not be
assembled7Parametros de proceso incorrectosIncorrect process
parameters2(P) Validacion de set-up IXFC172B, (D) Medicion y
registro en Hojas de inspeccion IXFC011(P) Set-up validation (D)
Measurement and record in inspection sheets456N / AN / AN /
AComponentes daados o faltantesComponent damaged or missingNo
ensamblaCan not be assembled7Parametros de proceso
incorrectosIncorrect process parameters2Validacion de set-up
IXFC172B.Validation of set-up IXFC172B.570N / AN / AN / ACriterios
de inspeccion en ayudas visuales IXAV011.Inspection criteria
IXAV011 visual aids.570N / AN / AN / ADesprendimiento de
terminal.Detachment terminal.La terminal es botada en el momento de
hacer el ensamble con el cliente.The terminal is launched at the
time of assembly with the client.7Falta de material para retener la
terminal despues del fundido.Lack of material to retain the
terminal after the heat stake.6No haywe dont have6252propuesta de
diseo para incrementar los postes para el soldado.R. Ventura.Se
realiz y entrego propuesta con cambio en la altura de los
postes.73363Modificar la herramienta acorde al diseo.O. Galindo.Se
modific el molde acorde al diseo.Realizar pruebas con molde
modificado en maquina.E. MarquezSe realizaron las pruebas en
maquina con el molde modificado.Modificar la altura del heat
stakingA. Rubio.Se modific la altura del heat staking.Implementar
prueba de push test y registro de datos.C. MonteroSe implement
prueba de push test y registro de datos en IXFC011Desprendimiento
de terminal durante el ensamble del arnes con el cliente.Terminal
detachment during assembly of the harness with the
client.Intermitencia en el ensamble final con el cliente.Flashing
in the final assembly with the client.7Parametros de proceso
incorrectos.Incorrect process parameters.2Validacion de set-up
IXFC172B.Validation of set-up IXFC172B.570N / AN / AN / ACriterios
de inspeccion acordes a la ayuda visual IXAV011Inspection criteria
consistent visual aid IXAV011570N / AN / AN / APrueba de push test
y registro de datos en IXFC011Test push test and data logging
IXFC011570N / AN / AN / ADesalineacin de teminales para arnes de 2
puntas.Misalignment of terminals for 2-point harness.El cliente no
puede hacer ensamble con arnes.The client can not join with
harness.7Perpendicularidad de terminales en el circuito fuera de
especificacin.Squareness of terminals in the circuit out of
specification.6No hay.We dont have5210Modificar diseo en la
herramienta para controlar perpendicularidad en terminal.D.
Ortiz.25-Sep-12Se modific el diseo de la herramienta y se controla
cambio en el sistema.73363Modificar la herramienta para poder
controlar parpendicularidad de la terminal.A. Alvarado.1-Ago-12Se
modific la herramienta para poder controlar la perpendicularidad en
la terminal.Incluir en la hoja de inspeccion de estampado el
control de perpendicularidad para esta cota.C. Montero4-Jul-12Se
incluy el control de perpendicularidad en la hoja de inspeccion de
estampado.7Perpendicularidad de terminales en el circuito fuera de
especificacin.Squareness of terminals in the circuit out of
specification.3No hay.We dont have5105Implementar uso de fixture
para verificar alineacin de terminal.E. Mrquez13-May-13Se implement
fixture para verificacion de alineacion de terminales, haciendo una
marca de un punto al fondo del alojamiento cuando la alineacion es
buena. Acorde a la IXIT251.733637Perpendicularidad de terminales en
el circuito fuera de especificacin.Squareness of terminals in the
circuit out of specification.3no hay.We dont have5105Implementar
monitoreo de la cota 3.59mm (distancia del conector a la
terminal)C. Montero20-Jun-12Se implement monitoreo de la cota
3.59mm (distancia del conector a la terminal)733637Suficiente
holgura en el ancho de la ventana en el housing, donde van estas 2
terminalesEnough space in the window width of the housing.3No
habiaThere is not.5105Reducir ancho de la ventana en el housing
para estas 2 terminales.R. Ventura. / O. Galindo1-Nov-13Se redujo
el ancho de las ventanas y se aumento el radio de la base de los
insertos en las 4 cavidades72570Desalineacin de teminales para
arnes de 4 puntas.Misalignment of terminals for 4-point harness.El
cliente no puede hacer ensamble con arnes.The client can not join
with harness.7Falta de soporte en el housing para la terminal.Lack
of support in the housing to the terminal.5no hay.We dont
have5175Hacer diseo de fixture para verificar la alineacion de las
terminales en el ensamble.R. GamezSe realiz el diseo de fixture
para verificar la alineacion de las terminales en el
ensamble.73363Fabricacin de fixture para verificar alineacin de
terminales.A. AlvaradoSe fabric fixture para verificar alineacin de
terminales.Implementar instruccin de trabajo para uso de fixture en
verificacin de alineacin de terminal.E. MrquezSe implement
instruccin de trabajo para uso de fixture en verificacin de
alineacin de terminal.Hacer propuesta de diseo en la herramienta.R.
Ventura.Se realiz propuesta con piramides en el diseo de la
herramienta.Modificacin de la herramienta con piramides.O.
Galindo.Se modific el molde acorde al nuevo diseo.Pruebas de molde
con modificacin.E. MarquezSe realizaron las pruebas en maquina con
el molde modificado.Liberacin de producto.Release product.50Cotas
crticas de la pieza dentro de control.Part dimensions reviews in
controlLa pieza se encuentra fuera de especificacin.The piece is
out of specification.El cliente no puede utilizar el producto en la
linea de ensamble.The client can not use the product on the
assembly line.8Desconocimiento del asociado para la inspeccion del
producto en linea.Lack of partner for online product
inspection.3Registro en hojas de inspeccin para producto terminado,
IXFC011.Registration sheets for finished product inspection,
IXFC011.372N / AN / AN / ACertificacin y registro del operador en
la linea de cada operacin que se realiza, IXFC040Operator
Certification and Registration in the line of each operation
performed, IXFC040372N / AN / AN / AEmpaque.Package.60ERP. Sistema
de control y manejo de materiales de Interplex.ERP. System control
and material handling InterplexPiezas daadas con el clienteCustomer
damaged partsPiezas de rechazo en linea del cliente.Parts Online
customer rejection.8Mal acomodo de piezas en las cajas.Bad
arrangement of parts in boxes.2Instruccin de empaque del
cliente.Customer packing instruction.232N / AN / AN / AEtiqueta
equivocadalabel wrongEl cliente no puede recibir productoThe client
can not receive product5Datos erroneos en la etiquetaWrong data in
the label2ERP. Sistema de control y manejo de materiales de
Interplex.ERP. System control and material handling Interplex.660N
/ AN / AN / AEl material no encontrado en almacn.The material found
in store.No se localiza el material para el embarque.Can not locate
the material for shipment.7Material colocado en rea
diferente.Material placed in different area.2ERP. Sistema de
control y manejo de materiales de Interplex.ERP. System control and
material handling Interplex.228N / AN / AN / ADesconocimiento del
sistema.Ignorance of the system.3Recoleccion de producto movimiento
y acomodo, IXIT202.Collection of product movement and
accommodation, IXIT202.363N / AN / AN / AHistorial de Cambios
(Changes history)Revision(Review)Fecha (Date)Autor
(Author)Descripcin de Cambios (Descripction of changes)A16-Jun-10D.
CamarenaInitial releaseB20-Jul-10D. CamarenaUpdated drawing
revision to 2L, added analysis for potential failures of missing
component, missing trimming, damaged heat stake17-Dec-12S.
GuzmanPush test Included per Car -2012-035221-May-13E. MarquezSe
actualizan operaciones de proceso en base al diagrama de flujo, se
incrementa altura de postes para soldado, se agregan piramides para
retener deforma perpendicular la terminal en 4 puntas, se incluye
control de perpendicularidad en el proceso de estampado y ensamble
de componentes, actualizacion de hojas de inspeccion en estampado y
ensamble, se implementa el uso de fixture VAL-5061-078, se
implementa monitoreo de la cota 3.59mm por variable, deacuerdo al
CAR-2012-034328-Nov-13V. HernandezSe agrego la reduccion del ancho
de la ventana del housing para el modo de falla desalineacion de
las 2 terminales, en la operacion # 80, de acuerdo al CAR #
2012-034. Tambien se actualizo la operacion # 50 agregandose el
control de flujo del aire del planchado y la modificacion del
IXFC172B de acuerdo al CAR # 13-19.417-Jun-14S. GuzmanSe actualizan
numeros de parte y formato de AMEF