MElec-Ch4 - 1

Chapter 4

Alternating CurrentPower

Page 2: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 2

Overview

• What is Alternating Current• AC Hazards• AC Power Requirements• Shoreside Utility System• On-Board Generators

Page 3: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 3

What is Alternating Current

• General Description

• Basic Terminology

Page 4: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 4

General Description

• Batteries provide limited amount of power Can’t run air conditioner or heater DC appliances are expensive

• Therefore need for AC on boat From shore power From on-board generator

• Need “Service Drop” Not an extension cord Safety hazards with AC power

Page 5: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 5

Basic Terminology

• Polarity – Hot, neutral and ground

• Voltage – 120 VAC

• Frequency – 60 Hz

• Resistance – DC opposition to current flow

• Reactance – AC opposition to current flow

• Voltage Drop – difference input & output

• Wave Form – Commercial AC is sine wave

Page 6: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 6

Sine Wave

• Plot of AC Voltage is Sine Wave

Page 7: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 7

AC Hazards

• Shock

• Fire

• Reversed Polarity

Page 8: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 8

Shock and Fire

• Shock AC “shock” could be lethal Marine environment increases this hazard Need GFCI protection

• Fire Inadequate wiring and overloaded cables Over fusing or no overload protection Heater on extension cord

Page 9: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 9

Reverse Polarity

120V HOT

NEUTRAL

CIRCUIT

BREAKER

NO SAFETY GROUND

CONNECTION

REVERSED POLARITY

2-WIRE OUTLET

GROUND

LOAD

120V POTENTIAL

EXISTS BETWEEN

BOAT NEUTRAL AND WATER

• Reverse Polarity is extremely dangerous- Neutral is “Hot” (120 VAC not 0 VAC)

- Produces stray current

Outlet checker indicates if AC outlet is correctly wired

Page 10: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 10

Reverse Polarity - 2• Receptacles are polarized

Plug can only be inserted one way• Modern receptacles are polarized & grounded

Narrow vertical slot is Hot (120 VAC) Longer vertical slot is Neutral (0 VAC) Rounded hole is Ground

• ABYC requires a Polarity Indicator Normally lights on AC power panel If reverse polarity light is “On”

• DO NOT USE SHORE POWER• Immediately disconnect the shore power cable

Page 11: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 11

AC Power Requirements

• Maximum Current Limitations

• Priority Usage Table

Page 12: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 12

Maximum Current Limitations

• Dockside Outlet

• Service Cord

• Boat’s Service Entrance

Page 13: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 13

Dockside Outlet• 30A outlet protected by 30A circuit breaker• 15 A outlet protected by 15A circuit breaker• If 15A to 30A adapter plugged into 15A outlet and

30A cable plugged into adapter Current available limited to 15 Amps

• A 30A to 20A adapter permits a 15A cord to be plugged into dockside outlet NOT SAFE!

• No GFCI protection• Outlet is overprotected

Page 14: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 14

Service Cord

• 30A, 120 VAC service cord wire is AWG #10• 50A, 120 VAC service cord wire is AWG #6• Service cords are 25 and 50’

Cords are rated for 50’ length

• Limit for #10 wire carrying 30A is 60’ Ch 2 Wire Size Selection Table When two 30A service cords connected together,

safe current is limited to 20 Amps

• Similar problem for two 50A cords

Page 15: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 15

Boat’s Service Entrance

• Has a maximum current rating Size for the service cord

• Service switch is DPST Breaks hot and neutral wires Normally left “On”

• If power is lost and circuit breakers are “On” Check service entrance switch

• Using one 30A service cord, rather than two and configuring power panel for one cord Service switch will trip if exceed 30A total

Page 16: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 16

Priority Usage Table

• Maximum current limited by smaller of: Dockside outlet and circuit breaker Service cord Service inlet and service switch (circuit breaker)

• Following table gives typical AC power use Everything cannot be on at same time Prioritize demand based on limiting factor

Page 17: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 17

Priority Scheme

Page 18: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 18

Shoreside Utility System

• Utility Power Distribution• Shoreside Outlets• Dockside Service Drop• Shore Power Service Cable• Connector Standards and Adapters• Service Entrance and Distribution

Page 19: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 19

Utility Power Distribution

• Power lines are at 2,300 VAC or higher

• Output from last transformer is 120/240 V If loads are balanced, no current in neutral Hot wires are Black and Red

• 120 VAC from either wire to neutral• 240 VAC between black and red wires

Center tap of transformer is grounded

• No current flows in ground (green) wire

Page 20: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 20

Shoreside Outlets

Page 21: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 21

Dockside Service Drops

• Shoreside power: 120/240 V 60 Hz Cords and plugs are called 125 or 125/250 V

• Boats under 30’: usually one 30A service cord• Boats between 30 & 40’: may use two 30A cords• Larger boats: one or two 50A 125/250 V cords• Neutral wire is grounded only at transformer• Inadequate service (brownout)

Line voltage under 100 VAC May damage motors (refrigerator, air-conditioner)

Page 22: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 22

Shore Power Service Cable

• Flexible, durable and oil/moisture resistant Called “Hard Service Cable” Compliant with NEC article 555 Outlets are female; Plugs are male Outlets / plugs are polarized with twist lock Outlets are “keyed” to prevent mismatch

30 Amps @ 125 V 50 Amps @ 125/250 V

Page 23: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 23

Connector Standards

50A 125V

30A125V

20A

125V

15A

125V

Page 24: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 24

Adapters

Reverse “Y”

Two 30A 125 V to

One 50A 125/250 V

15 A to 30 A 50 A to two 30 A

50 A 125/250 to

one 30A 125 V

Page 25: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 25

Service Entrance & Distribution

• Service Entrance Connector• Isolation Transformer• Galvanic Isolator• AC Distribution Panel• Branch Circuit Conductors

Page 26: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 26

Service Entrance Connector• Normally one or two

30A 125 V or 50A 125 V or 50A 125/250 V Most houses have 200A 125/250 V

• Close weatherproof cover when not in use Clean contacts with Electronic Cleaner

• Sequence for Shore Power service cord Turn “Off” all circuit breakers Connect boat end first Then connect shore end Turn “On” shore circuit breaker Check Reverse Polarity for proper connection Turn “On” boat Main then Branch circuits

Page 27: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 27

Isolation Transformer

• No direct electrical connection between boat and shore power Avoids reversed polarity hazard Stops stray current Big $ and weight

Page 28: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 28

Galvanic Isolator

• Solid state - large capacitor and power diode

In series with green ground wire

Blocks DC and low AC voltage

Stops Stray current

Page 29: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 29

Boat AC Distribution Panel• Review of Chapter Two• Normally combined with DC power panel

Main (Shore Power) circuit breaker• Not Service Switch (near input connector)• Breaks both hot and neutral

Branch circuit breakers• Breaks only hot wire

• All AC circuits are 3-wire

Page 30: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 30

Branch Circuit Conductors• Review of Chapter Two• Wiring is stranded 3-wire UL 1426 BC cable

Normally 14 AWG for 15A circuits Normally 12 AWG for 20A circuits

• All neutral & ground wires returned to panel• Support wires every 18” • Ring connectors on both ends of wires

Page 31: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 31

On-Board Generators

• Inverters• Propulsion-engine driven generator• Auxiliary-engine driven generator• Isolation from Shore Power Entrance

Page 32: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 32

Inverters

• Convert DC to AC 12 VDC to 120 V 60 Hz Efficiency 90 to 95%

• Sizes from 50 to 3,000 watts 1200 watts of 120 VAC draws 110A of 12 VDC

• Outputs are 120 V 60 Hz True Sine Wave are expensive

• Run all loads Modified Sine Wave are less expensive

• May damage sensitive electronic equipment

Page 33: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 33

Modified Sine Wave

• Modified Sine Wave and Sine Wave Voltage Either waveform will deliver the same power to a

resistive load

Page 34: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 34

Inverters - 2• Automatically disconnect output when shore

power or generator power is connected• May produce interference

Mitigation is discussed in Chapter 7• Combined Inverter/Charger (illustrated)

Either charge batteries or generate AC Lighter and cheaper than separate systems

Page 35: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 35

Propulsion-Engine Driven

• AC Generators driven by propulsion engine Can only be used while underway Will not produce full output at idle

• Not as efficient as auxiliary driven generator

Page 36: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 36

Auxiliary-Engine Driven

• Directly coupled to small gas or diesel engine Fuel should be same as propulsion engine

• Solution if need over 2 Kw of 60 Hz power• Big, heavy and noisy

Page 37: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 37

Isolation from Shore Power

• Inverters automatically only provide power to AC bus when no other AC power is present

• On-board Generators must also be isolated Normally done by transfer switch

• Neutral and ground are connected at generator

Page 38: Alternating Current Powerarmarine.weebly.com/uploads/1/0/3/3/10331435/ch_4... · Alternating Current Power. MElec-Ch4 - 2 Overview • What is Alternating Current • AC Hazards ...

MElec-Ch4 - 38

Summary

• Polarity reversed: Don’t use shore power

• Nominal shoreside power: 120/240 volts, 60 Hz

• Maximum current limited (smaller of): Dockside circuit breaker, dockside outlet Service cord and boat’s service entrance

• Priority scheme for AC appliances needed

• Outlets must be 3-wire polarized GFCI in galley, head, machinery spaces & weather deck

• Inverters: for short term loads under 2 Kw

• Generators: for long term loads over 2 Kw

• Use transfer switch with inverter or generator