Top Banner
Agricultural Designed Motors & Controls 508A Agricultural Catalog
66

alog - naemotors.com

Oct 16, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: alog - naemotors.com

Agricultural Designed Motors amp Controls

508A

Agricu

ltural C

atalog

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer expectations for quality performance and reliability at the lowest possible cost and delivered within the customerrsquos schedule through our authorized distribution network

COMPANY HISTORY

In 1993 North American Electric began sourcing high quality high performance electric motors and gearing from around the world and distributed the on a national and international level In 2014 we opened our NAE Motor Controls division enabling us to offer our wholesale distribution network complete automation solutions

Controls Motors Gear Reducers

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)

CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)

ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled

SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available

CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)

MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)

SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet

SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction

THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet

THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)

THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction

ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)

GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)

ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Program

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

ldquoNo Hasslerdquo Chassis

Exchange Program

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage

protection Single phasing phase reversal and voltage

unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis

(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)

Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance

ldquoProviding reliable control panel

service for up to six (6) yearsrdquo

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 2: alog - naemotors.com

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MISSION STATEMENT To provide complete automation solutions for the United States and international market with products and service that meet or exceed customer expectations for quality performance and reliability at the lowest possible cost and delivered within the customerrsquos schedule through our authorized distribution network

COMPANY HISTORY

In 1993 North American Electric began sourcing high quality high performance electric motors and gearing from around the world and distributed the on a national and international level In 2014 we opened our NAE Motor Controls division enabling us to offer our wholesale distribution network complete automation solutions

Controls Motors Gear Reducers

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)

CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)

ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled

SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available

CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)

MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)

SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet

SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction

THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet

THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)

THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction

ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)

GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)

ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Program

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

ldquoNo Hasslerdquo Chassis

Exchange Program

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage

protection Single phasing phase reversal and voltage

unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis

(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)

Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance

ldquoProviding reliable control panel

service for up to six (6) yearsrdquo

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 3: alog - naemotors.com

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

STAINLESS STEEL WASHDOWN DUTY MOTORS 13 HPmdash20 HP 2 4 or 6-Pole C-Flange w Feet or Round Body Inverter Duty (201 VT 101 CT)

CLOSE COUPLED PUMP MOTORS 1 HPmdash75 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS TEFC 2 HPmdash150 HP 6 or 8-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

OIL WELL PUMP MOTORS ODP 75 HPmdash100 HP 6-Pole NEMA Design D High Slip (5mdash8 Slip) Special Purpose Oil Well Pump Motors Inverter Duty (201 VT 101 CT)

VERTICAL HOLLOW SHAFT PUMP MOTORS 10 HPmdash500 HP 4-Pole Extra High Thrust Double Stacked Bearings Available Inverter Rated (101 VT) or Inverter Duty (201 VT)

ROTARY UNIT MOTOR FOR ROTARY PHASE CONVERTER 3 HPmdash60 HP 4-Pole For Use with Rotary Phase Converters To Run Three Phase Equipment From Single Phase Power Totally Enclosed Fan Cooled

SHAFT MOUNT REDUCERS amp ACCESSORIES 2mdash10 Box Size Gear Ratios 151 or 251 Screw Conveyor Adaptors Available Repair Kits Also Available

CONTROLS Safety Switches Across the Line Starters (ATL) Part Wind Starters (PWS) Soft Starters VFDs (Available in NEMA 3R 4 4X and 12)

MOTOR SLIDE BASES Available 56mdash505U Frame Single-Adjusting Screw Type (56mdash145T Frame) Double-Adjusting Screw Type (182Tmdash505U Frame)

SINGLE PHASE 56C FRAME TEFC 13 HPmdash2 HP 2 or 4-Pole High Starting Torques Capacitor Start Capacitor Run Design Rolled Steel Construction Removable Feet

SINGLE PHASE COMPRESSOR DUTY ODP 3 HPndash5 HP 2 or 4-Pole High Starting Torque Capacitor Start Capacitor Run Design Rolled Steel Construction

THREE-PHASE 56C FRAME TEFC 13 HPmdash3 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction Removable Feet

THREE-PHASE OPEN DRIP PROOF 1 HPmdash20 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

EXPLOSION PROOF MOTORS 1mdash250 HP 2 4 or 6-Pole All Motors Meet or Exceed UL 674 Specification As Required By OSHA For Installation and Use In Hazardous Locations Totally Enclosed Explosion Proof (TEXP) Inverter Rated (101 VT 51 CT)

THREE-PHASE TEFC 1 HPmdash10 HP 2 or 4-Pole High Starting Torque Rolled Steel Construction

SINGLE PHASE FARM DUTY TEFC 13 HPmdash10 HP 2 or 4-Pole High Starting Torques Manual Overload Protection (13 HPmdash5 HP) Capacitor Start Capacitor Run Design Rolled Steel Construction

ALUMINUM FRAME INVERTER DUTY MOTORS 1 HPmdash10 HP 2 or 4-Pole Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

CRUSHER DUTY MOTORS 1 HPmdash600 HP 4 6 or 8-Pole NEMA Design C Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (250 HPmdash600 HP)

GENERAL PURPOSE INVERTER DUTY MOTORS 1 HPmdash300 HP 2 4 6 or 8-Pole NEMA Design B Totally Enclosed Fan Cooled or Open Drip Proof Inverter Duty (201 VT 101 CT)

ROUND BODY MOTORS 1 HPmdash30 HP 4-Pole 1800 RPM C-Flange without Feet Totally Enclosed Fan Cooled Inverter Duty (201 VT 101 CT)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Program

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

ldquoNo Hasslerdquo Chassis

Exchange Program

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage

protection Single phasing phase reversal and voltage

unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis

(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)

Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance

ldquoProviding reliable control panel

service for up to six (6) yearsrdquo

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 4: alog - naemotors.com

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Program

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

ldquoNo Hasslerdquo Chassis

Exchange Program

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program Warranty period is three (3) years from the date of delivery and must be activated by an NAE Authorized or Certified Installer This warranty protection may be extended to cover the chassis or the entire panel for up to six (6) years Program warranty benefits include Lightning surge and severe overvoltage

protection Single phasing phase reversal and voltage

unbalance protection ldquoBumper to Bumperrdquo panel coverage Same day shipment of exchange chassis

(Next Day Air Second Day Air and Hot Shot Service is available for an additional charge)

Visit our website at wwwnaemotorscomchassis exchangeprogram for complete terms and conditions

NAE ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your soft starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime ldquoBUMPER TO BUMPERrdquo COVERAGE Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage and includes ldquoLightning amp Surgerdquo Protection covering momentary anomaly including line side events such as lightning surge and severe overvoltage and load side events such as single phasing phase reversal and voltage unbalance

ldquoProviding reliable control panel

service for up to six (6) yearsrdquo

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 5: alog - naemotors.com

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 6: alog - naemotors.com

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 6

COUPLING

INCLUDED IN PRICE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Corrosion Resistant Epoxy Paint

⓲ Lifting Provisions

⓳ Two (2) Year Warranty (Extended Warranty Available)

⓴ Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Suitable for use with variable frequency drives

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 7: alog - naemotors.com

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 7

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER RATED (101 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V1 SERIES

VHSmdashV1 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Rated (101 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V1 SERIESmdash INVERTER RATED (101 VT)

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 8: alog - naemotors.com

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 8

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V

3 Zinc Plate Steel Frame Construction

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

Standard Features Include ❶ 10 HPmdash500 HP in Stock

❷ 115 Service Factor 60 Hertz

❸ Oversized Angular Contact Bearing and Ball Bearing

Insulated Bearing Mount (40 HPmdash500 HP)

High Thrust (10 HPmdash250 HP)

Extra High Thrust Double Stacked Bearing Available (100 HPmdash500 HP)

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance

❽ Enclosure WP1mdashOpen Weather-Protected Machine Type 1

❾ Non-Reverse Ratchet (Ball Type)

❿ Dual Voltage Ratings Suitable for Part Wind Start at 230V

Single Voltage Ratings are Suitable for Part Wind Start at 460V

⓫ Oil Bath with Large Reservoir (40 HPmdash500 HP)

⓬ Cast Iron Plate Steel Frame Construction

⓭ Light Weight Hood for Easy Access

⓮ Space Heaters

⓯ Resistance Temperature Detector (RTD) (300 HPmdash500 HP)

⓰ Thermal Protected

⓱ Windings Rated for 2200V Peak Voltage Spikes

⓲ Corrosion Resistant Epoxy Paint

⓳ Lifting Provisions

⓴ Two (2) Year Warranty (Extended Warranty Available)

mdash Parts and Accessories Available5

APPLICATIONS Designed primarily for deep well turbine pump applications The coupling is equipped with a non-reverse ratchet which prevents motor rotation from backspin at shutdown These motors are built to NEMA standards and have special bearing arrangements to carry heavy thrust loads Recommended for use with variable frequency drives

COUPLING

INCLUDED IN PRICE

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 9: alog - naemotors.com

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 9

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

INVERTER DUTY (201 VT)

HIGHEXTRA HIGH THRUST DESIGN 215TPmdash5008P FRAME

OPEN WEATHER-PROTECTED MACHINE TYPE 1mdashWP1 THREE-PHASE

V2 SERIES

VHSmdashV2 Series Cast Iron Plate Steel Three-Phase 215TPmdash5008P Frame Open Weather-Protected Machine Type 1mdashWP1 Inverter Duty (201 VT) High Extra High Thrust

1 Suitable for Part Wind Start on 230V 2 Suitable for Part Wind Start on 460V 3 Zinc Plate Steel Frame Construction

LIGHTWEIGHT HOOD

OIL PLUG

SIGHT GAUGE

Performance Data Dimensions found at naemotorscom Accessories on pp 10mdash11

Warranty on p 64

V2 SERIESmdash INVERTER DUTY (201 VT)

4 Extra High Thrust Double Stacked Bearing Design 5 Please reference pp 10mdash11 for parts and accessories or contact us at 800-884-0404 for assistance

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 10: alog - naemotors.com

VER

TIC

AL

HO

LLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 10

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

REPLACEMENT PARTS

V1 AND V2 SERIES

AccessoriesmdashVHS V1 and V2 Series

Ball Bearing Non-Reverse Ratchet Assembly

Lubriport Sight Glass

Model Number HP FrameWeight

(lbs)

Mult

Symbol List Price

SG-LUBRIPORT 40-500 ALL 033 M15 9623$ Alternative Bases

Top Cover

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 11: alog - naemotors.com

VER

TICA

L H

OLLO

W

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 11

AccessoriesmdashVHS V1 and V2 Series

10 HPmdash500 HP VERTICAL HOLLOW SHAFT

MOTOR COUPLINGS

V1 AND V2 SERIES

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 12: alog - naemotors.com

R

OLL

ED

STE

EL

12 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

General PurposemdashFarm Duty Single Phase 56Cmdash215T Frame Totally Enclosed Fan Cooled (TEFC)

APPLICATIONS General purpose use on pumps fans conveyors poultry equipment air compressors and other farm duty machinery requiring high starting torque

13 HPmdash10 HP FARM DUTY ROLLED STEEL

56Cmdash215T FRAME

SINGLE PHASE TEFC

Performance Data Dimensions found at naemotorscom

Warranty on p 64

sup1 Removable Feet on 56CCH motors only

sup2 Does not have Manual Overload Protection

Standard Features Include ❶ 13 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor for 10 HP Only

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility1

❾ Manual Overload Protection (13 HPmdash5 HP)

❿ Capacitor Start Capacitor Run Design

⓫ Corrosion Resistant Epoxy Paint

⓬ Lifting Provision on 182T and Above

⓭ Condensation Drains with Plugs

⓮ IP55 Protection

⓯ Two (2) Year Warranty

⓰ C-Flange Field Conversion Kits Available

SINGLE PHASE

56Cmdash56CH

143Tmdash145T

213Tmdash215T

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 13: alog - naemotors.com

R

OLLED

STEEL

13 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial and commercial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

1 HPmdash10 HP GENERAL PURPOSE

ROLLED STEEL

143Tmdash215T FRAME THREE-PHASE

TEFC

General PurposemdashRolled Steel Three Phase 143Tmdash215T Frame Totally Enclosed Fan Cooled (TEFC) Inverter Rated (101 VT 51 CT) NEMA MG-1 PART 31 TABLE 12-12

Standard Features Include ❶ 1 HPmdash10 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

❸ Sealed Bearings

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Corrosion Resistant Epoxy Paint

❿ Lifting Provision

⓫ Condensation Drains with Plugs

⓬ IP55 Protection

⓭ Three (3) Year Warranty (Extended Warranty Available)

⓮ C-Flange Field Conversion Kits Available

Performance Data Dimensions found at naemotorscom

Warranty on p 64

THREE-PHASE

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 14: alog - naemotors.com

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

14

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Standard Features Include ❶ 1 HPmdash600 HP in Stock

❷ 115 Service Factor 60 Hertz 10 Service Factor 50 Hertz

Suitable for 575V 10 Service Factor

❸ Sealed Bearings Through 215T Frame

Regreasable Open Bearings 254T Frame and Above

Insulated Bearing on ODE Available on 444T and Above

❹ Class F Insulation System Class B Rise at Full Load

Class H Vacuum Pressure Impregnation (VPI) Resin for All Windings

❺ 40o C Ambient Continuous Duty

❻ Stainless Steel Nameplate and Zinc Plate Hardware

❼ NEMA Design B Performance High Starting Torque

❽ Feet are Dual Drilled for Mounting Flexibility

❾ Dual Voltage Ratings Suitable for Part Wind Start on Lower Voltage

Single Voltage (460V) Ratings are Suitable for Part Wind Start

❿ Corrosion Resistant Epoxy Paint

⓫ F1 F2 Reversible

⓬ Lifting Provision

⓭ Condensation Drains with Plugs

⓮ Windings Rated for 2200V Peak Voltage Spikes

⓯ IP55 Protection

⓰ Three (3) Year Warranty (Extended Warranty Available)

⓱ C-Flange amp D-Flange Field Conversion Kits Available

1 HPmdash300 HP

350 HPmdash600 HP

APPLICATIONS General purpose use on pumps fans blowers compressors conveyors material handling and other industrial machinery installed in damp dusty or dirty environments Suitable for use with variable frequency drives

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 15: alog - naemotors.com

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 15

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 16: alog - naemotors.com

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

16

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

G

ENER

AL

PU

RP

OSE

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 17

General PurposemdashHeavy Duty Cast Iron Three-Phase 143Tmdash5867UZ Frame Totally Enclosed Fan Cooled (TEFC) Inverter Duty (201 VT 101 CT) (1 HPmdash300 HP) Inverter Rated (101 VT 51 CT) (350 HPmdash600 HP) NEMA MG-1 PART 31 TABLE 12-12 (unless otherwise noted) CLASS I DIV II GROUPS ABCD T2B CLASS II DIV II GROUPS F amp G

Performance Data Motor Dimensions found at naemotorscom

Warranty on p 64

1 HPmdash600 HP GENERAL PURPOSE

CAST IRON

143Tmdash5867UZ FRAME THREE-PHASE

TEFC

1 NEMA Premiumreg (NEMA MG-1 Table 12-12) 2 Inverter Duty (201 Variable Torque 101 Constant Torque) 3 12 Lead Part Wind Start at 230V 4 6 Lead Part Wind Start at 460V

5 Ball Bearing on Drive End 6 Insulated Bearing on Opposite Drive End 7 Equipped with Terminal Blocks as Standard 8 Inverter Rated (101 Variable Torque 51 Constant Torque)

SAFE

TY

SWIT

CH

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 18

Safety SwitchDisconnect Panel 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

3-POLE3-WIRENON-FUSED OR FUSED NEMA 3R ENCLOSURE

HEAVY DUTY RATED NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Two (2) Year Warranty Most Orders Ship Within

24 HOURS

Warranty on pp 60mdash61

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4584

SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $9604

SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $11852

SFTYSW-NK-TNI65 400A 600V Neutral Kit $20936

SFTYSW-NK-TNI66 600A 600V Neutral Kit $20936

SFTYSW-NK-TNI67 800A 600V Neutral Kit $44556

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $61344

SAFETY

SW

ITC

H

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021 19

Warranty on pp 60mdash61

Safety SwitchDisconnect Panel w ldquoLightning amp Surgerdquo Protection 480VAC 600VAC 3-Pole 3-Wire Non-Fused or Fused Heavy Duty Rated

PROTECTS AGAINST LIGHTNING STRIKES

AND EXTREME SURGES

480VAC600VAC 30 AMPmdash1200 AMP SAFETY SWITCHDISCONNECT

w ldquoLIGHTNING amp SURGErdquo 3-POLE3-WIRENON-FUSED OR FUSED

NEMA 3R ENCLOSURE HEAVY DUTY RATED

NON-FUSED or FUSED w FLANGED

Standard Features for Base Models Include ❶ 30 AMPmdash1200 AMP Ratings in Stock

❷ NEMA 3RmdashHeavy Duty Enclosure

❸ 3-Pole 3-Wire Non-Fused or Fused

❹ Rated for 480VAC 600VAC

❺ Highly Visible Easy-to-Grip Handle

❻ Visible Blade Construction

❼ Door Opens 180deg or Greater

❽ All Copper Current Carrying Parts

❾ Quick-Make Quick-Break Mechanism

❿ Positive Two and Three Point Mounting

⓫ Front Removable Lugs Can Easily be Converted

to Copper Body or Compression Type Lugs

⓬ Lugs Suitable for Copper (60degC) or Aluminum (75degC)

⓭ Padlockable Cover Latches and Disconnect Handle

⓮ UL 508A Certified

⓯ Three (3) Year Warranty with ldquoLightning

amp Surgerdquo Protection

Most Orders Ship Within

24 HOURS

NON-FUSED

Neutral Kit Options

Model Number Amp Rating Volt Description List Price

SFTYSW-NK-TNI62 30A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA62 60A 600V Fusible Neutral Kit $4864 SFTYSW-NK-TNIA63 100A 600V Fusible Neutral Kit $10189 SFTYSW-NK-TNIA64 200A 600V Fusible Neutral Kit $12574 SFTYSW-NK-TNI65 400A 600V Neutral Kit $22211 SFTYSW-NK-TNI66 600A 600V Neutral Kit $22211 SFTYSW-NK-TNI67 800A 600V Neutral Kit $47270

SFTYSW-NK-TNI68A 1200A 600V Neutral Kit $65080

ATL

20 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ATL SERIES ACROSS THE LINE - STARTER PANELS

Model Number Assembler

Select the option code from each box to build your control panel

ATL-IRR-460-N3-BRKR-13A-000

Product Series

ATL ndash Across the Line

Supply Voltage

230 ndash 240V

460 ndash 480V

Series

IRR ndash Irrigation

NEMA Size

N1 ndash 1

N2 ndash 2

N3 ndash 3

N4 ndash 4

N5 ndash 5

Disconnect Type

FUSD ndash Fused

BRKR ndash Circuit Breaker

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available mdash Please

refer to page 27 or contact us at

800-884-0404 for assistance

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 27)

ATL

21 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor

ATL

22 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

IRRIGATION PUMP NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for

Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashIrrigation Panel Special Purpose for Irrigation Pump Application Fused with Flanged Disconnect NEMA Full Rated Contactor

ATL

23 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 CIRCUIT BREAKER

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP

CIRCUIT BREAKER w FLANGED Standard Features for Base Model Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker w Flanged Disconnect

❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

ATLmdashStandard Panel General Purpose Application Circuit Breaker with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

ATL

24 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Standard Features for Base Models Include ❶ NEMA 1mdashNEMA 5 Sizes in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused w Flanged Disconnect ❹ Full NEMA Rated Contactor

Interchangeable Coils for Easy Field Conversion Between 240V and 480V (No Special Tools Needed) ❺ Solid State Overload

One Overload Covers Entire HP (Amp) Range for Each NEMA Size

❻ Overload Reset Button ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ 120V Fused Control Power (Transformer) ⓫ Heavy Duty Mounting Ears ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Most Orders Ship Within

24 HOURS

Options on p 27 Warranty on pp 60mdash61

240V480V 2 HPmdash200 HP ACROSS THE LINE STARTER

w 120V TRANSFORMER NEMA 1mdashNEMA 5 FUSED

NEMA 3R ENCLOSURE

FULL NEMA RATED CONTACTOR 240V 2 HPmdash100 HP 480V 3 HPmdash200 HP FUSED w FLANGED

ATLmdashStandard Panel General Purpose Application Fused with Flanged Disconnect NEMA Full Rated Contactor 120V Fused Control Power (Transformer)

240V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-230-N1-FUSD-24S 1 2 - 75 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-230-N2-FUSD-24S 2 10 - 15 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-230-N3-FUSD-24S 3 20 - 30 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-230-N4-FUSD-24S 4 40 - 50 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-230-N5-FUSD-24S 5 60 - 100 130 - 270 470 304 100 285 M70

480V with 120V Transformer NEMA

Model Number Size H W D

ATL-IRR-460-N1-FUSD-24S 1 3 - 10 64 - 32 293 209 70 85 M70 98082$

ATL-IRR-460-N2-FUSD-24S 2 15 - 25 15 - 75 293 209 70 90 M70 111492$

ATL-IRR-460-N3-FUSD-24S 3 30 - 50 22 - 110 424 248 86 195 M70 148912$

ATL-IRR-460-N4-FUSD-24S 4 60 - 100 30 - 150 424 248 86 195 M70 254822$

ATL-IRR-460-N5-FUSD-24S 5 125 - 200 130 - 270 470 304 100 285 M70 561144$

HPsup1Amp

Range

Dimensions (Inches)Weight List Price

Weight List Price

Mult

Symbol

Mult

SymbolHPsup1

Amp

Range

Dimensions (Inches)

ATL

25 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 27 Warranty on pp 60mdash61

240V 1 HPmdash100 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash100 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor ❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

26 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

480V 1 HPmdash200 HP WASHDOWN

ACROSS THE LINE STARTER w120V TRANSFORMER

CIRCUIT BREAKER NEMA 4X ENCLOSURE

IEC RATED CONTACTOR

CIRCUIT BREAKER wTHROUGH-DOOR Standard Features for Base Model Include ❶ 1 HPmdash200 HP ❷ Fully Gasketed NEMA 4X Stainless Steel Enclosure ❸ Combination Circuit Breaker w Through-Door Disconnect

❹ IEC Rated Contactor

❺ Thermal Overload (Class 10) w Phase Loss Protection ❻ Illuminated Fault Reset Pushbutton ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ 120V Fused Control Power (Transformer) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

Options on p 27 Warranty on pp 60mdash61

ATLmdashWashdown Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect IEC Rated Contactor 120V Fused Control Power (Transformer)

ATL

27 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67 3 Requires Transformer

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

ATL SERIES ACROSS THE LINE STARTER (ATL) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

TC75 34 Diameter $2722

TC100 1 Diameter $2722

TC125 1 14 Diameter $1577

TC150 1 12 Diameter $2722

TC200 2 Diameter $2722

TC250 2 12 Diameter $1603

TC300 3 Diameter $7011

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

- We Stock Fuses for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

FUSES

SPACE HEATERS3

MISCELLANEOUS

PROTECTION MECHANISMS3

METERS3

TIMERS3

UNIVERSAL RAINTIGHT HUBS

ADVANCED FAULT STATUS MONITORING OPTIONS3

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS3

SELECTOR SWITCHES

PA

RT

WIN

D

STA

RT

ERS

28 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

1000 SERIES ATLPWS STARTER PANELS

Model Number Assembler

1100B-1004TCE1-13A-4-000 Product Series

1 - Starter

Series

0 - ATL

1 - PWS

2 - Submersible

3 - Wye - Delta

4 - Duplex

9 - Operator Station

Disconnect Type

B - Breaker

D - Disconnect

F - Fused

N - None

Control Voltage

A - 208VAC60HZ

H - 120VAC60HZ

B - 240VAC60HZ

C - 480VAC60HZ

D - 24VDC

Overload

XX ndash None

T1 - Thermal Class 10

T2 - Thermal Class 20

T3 - Thermal Class 30

E1 - Electronic Class 10

E2 - Electronic Class 20

E3 - Electronic Class 30

E4 - Elec Class 5-10-20-30

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 31)

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

refer to page 31 or contact us

at 800-884-0404 for assistance

Type

00 - 3Ph Non Reversing

10 - 3Ph Reversing

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

030 - 30

hellip

hellip

NS1 - NEMA Size 1

NS2 - NEMA Size 2

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

PA

RT W

IND

STA

RT

ERS

29 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

Standard Features for Base Models Include ❶ 10 HPmdash200 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ IEC Rated Contactors ❺ Thermal Overload (Class 20) w Phase Loss Protection ❻ Overload Reset Pushbuttons ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Heavy Duty Mounting Ears ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓮ Other Options Available

Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash200 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

CIRCUIT BREAKER NEMA 3R ENCLOSURE

IEC RATED CONTACTORS 240V 10 HPmdash75 HP

480V 10 HPmdash200 HP CIRCUIT BREAKER wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

PA

RT

WIN

D

STA

RT

ERS

30 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 31 Warranty on pp 60mdash61

240V480V 10 HPmdash100 HP PART WIND STARTER

IRRIGATION PUMP w 120V TRANSFORMER

FUSED NEMA 3R ENCLOSURE

IEC RATED CONTACTORS

240V 10 HPmdash50 HP 480V 10 HPmdash100 HP

FUSED wTHROUGH-DOOR

PWSmdashStandard Panel General Purpose Application Combination Circuit Breaker Disconnect IEC Rated Contactors 120V Fused Control Power (Transformer)

Standard Features for Base Model Include ❶ 10 HPmdash100 HP in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Fused Through-Door Disconnect ❹ IEC Rated Contactors

❺ Thermal Overload (Class 20) w Phase Loss Protection

❻ Overload Reset Pushbuttons

❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Accepts Type R Fuses (In StockmdashSold Separately) ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection ⓯ Other Options Available

PA

RT W

IND

STA

RT

ERS

31 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

1000 SERIES PART WIND STARTER (PWS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

001 ATL PWS Overload Reset Pushbutton $15552

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

FUSES - We Stock Fuses for Convenience Please Call for Pricing

SPACE HEATERS034 Space Heater with Thermostat $46008

MISCELLANEOUS054 Transformer $16092

PROTECTION MECHANISMS41 Surge suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

METERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

SOFT

ST

AR

TER

S

32 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Model Number Assembler

3032B-1004TP00-13A-4-000 Product Series

3 - RVSS

Torque

0 - Normal Duty

1 - Heavy Duty

2 - Submersible

Drive BrandSeries

20 - SAF MS6

31 - ABB PSR

32 - ABB PSE

40 - Siemens 3RW30

41 - Siemens 3RW40

42 - Siemens 3RW44

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

6 - 6903PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility

Status Light

030mdashElapsed Time Meter

mdash Multiple Options

Available (p 35)

Horsepower

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

hellip

hellip

700 - 700

Purpose

P00mdashGeneral

Purpose

Control Option Package

Eg 13A HandOff Auto (HOA)

Start Pushbutton

Overload Reset Button

Other Options Available - Please

Refer to page 35 or contact us

at 800-884-0404 for assistance

3000 SERIES RVSS (SOFT STARTER) PANELS

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon

N4 - NEMA 4 4FmdashNEMA 4X Fiberglass

4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

SOFT

STA

RT

ERS

33 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35 Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 SOFT STARTER

IRRIGATION PUMP NORMAL DUTY

NEMA 3R ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 15 HPmdash300 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

Soft StartermdashIrrigation Panel Special Purpose for Irrigation Pump Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

SOFT

ST

AR

TER

S

34 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on p 35

Warranty on pp 60mdash61

240V480V SIEMENS 3RW40 WASHDOWN

SOFT STARTER NORMAL DUTY

NEMA 4X ENCLOSURE 240V 15 HPmdash150 HP

480V 25 HPmdash300 HP CIRCUIT BREAKER w THROUGH-DOOR

Soft StartermdashWashdown Normal Duty Panel Food and Beverage Corrosion Resistant Application Combination Circuit Breaker Disconnect Siemens 3RW40 Series Device

Standard Features for Base Model Include ❶ 15 HPmdash300 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Combination Circuit Breaker Disconnect ❹ Siemens 3RW40 Series Device

Integrated ByPass Contact System

Adjustable Current Limiting

Intrinsic Device Protection

LED Status Fault Monitoring

Remote Reset

Motor Overload Protection (Class 10) ❺ Isolation Contactor ❻ Illuminated Start Pushbutton ❼ Hand Off Auto (HOA) Selector Switch ❽ Illuminated Fault Reset Pushbutton ❾ Surge Suppressor ❿ Heavy Duty Mounting Ears ⓫ Padlockable Door and Disconnect ⓬ Service Entry Rated ⓭ UL 508A Certified ⓮ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓯ Other Options Available

SOFT

STA

RT

ERS

35 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty Details on pp 66mdash67

MotorSaverreg is a registered trademark of SymCom Inc

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

3000 SERIES REDUCED VOLTAGE SOFT STARTER (RVSS) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side singlephasing phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SPACE HEATERS

METERS

TIMERS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

36 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

2000 SERIES VARIABLE FREQUENCY DRIVE PANELS

Model Number Assembler

2010B-1004TP00-13M-4-000

Environmental Enclosure Rating

N1mdashNEMA 1 4XmdashNEMA 4X 304 SS 3RmdashNEMA 3R FXmdashNEMA 4X 304 SS Flanged FRmdashNEMA 3R Flanged 4SmdashNEMA 4X 316 SS T2mdashNEMA 3R Tunnel FSmdashNEMA 4X 316 SS Flanged T3mdashNEMA 3R Flanged Tun 4PmdashNEMA 4X Polycarbon N4 - NEMA 4 4FmdashNEMA 4X Fiberglass 4F - NEMA 4 Flanged 42mdashNEMA 12 4T - NEMA 412 F2mdashNEMA 12 Flanged FT - NEMA 412 Flanged

Product Series

2 - VFD

Horsepower

005 - 5

7P5 - 75

010 - 10

015 - 15

020 - 20

025 - 25

030 - 30

700 - 700

Disconnect Type

B - Breaker

F - Fused

N - None

Supply Voltage

1 - 2083PH

2 - 2403PH

4 - 4803PH

5 - 5753PH

Specification Information

000mdashNone

SPCmdashSpecial Instructions

065mdashHigh Visibility Status Light

mdash Multiple Options Available

(pp 49mdash50 62mdash64)

Purpose

P00 - General Purpose

P01 - Irrigation (IRR)

P02 - Positive Displacement

Pump (PDP)

P1B - ReGen Avoidance

P1C - ReGen Drive

INT - Integrator

Torque

0 - VT (120) Normal Duty

1 - CT (150) Heavy Duty

2 - Submersible

4 - Duplex

Control Option Package

Eg 13M HandOff Auto (HOA)

Start Pushbutton

1 Turn Potentiometer

Other Options Available - Please

refer to pp 49mdash50 62mdash64 or

contact us at 800-884-0404 for

assistance

Drive BrandSeries

1x - LSIS

10 - IS7

11 - C100

12 - H100

13 - S100

14 - S100 4X

5x - SIEMENS

50 - G120

55 - G120X

51 - G130

52 - V20

VFD

s

37 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

Standard Features for Base Model Include ❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (15 HPmdash60 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓫ Leg Stands Included (15 HPmdash60 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓱ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

38 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2 Line Side Harmonic Filtering including Line Reactor

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓫ Leg Stands Included (25 HPmdash150 HP) ⓭ Padlockable Door and Disconnect ⓮ Service Entry Rated ⓯ UL 508A Certified ⓰ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓱ Other Options Available

LSis S100 and iS7 ECONOMY PACKAGE 1-PHASE TO 3-PHASE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP

CIRCUIT BREAKER

Options on pp 43mdash44 Warranty on pp 60mdash61

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

VFD

s

39 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 1 HPmdash60 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM Standard Features for Base Model Include

❶ 1 HPmdash60 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash10 HP Windowed 15 HPmdash60 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (15 HPmdash60 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash10 HP) Flanged (15 HPmdash60 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash60 HP) ⓯ Leg Stands Included (15 HPmdash60 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

1 HPmdash75 HP

10 HP

15 HPmdash60 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

40 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

LSis S100 and iS7 IRRIGATION PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 1 HPmdash150 HP CIRCUIT BREAKER

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

1 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash150 HP

Standard Features for Base Model Include ❶ 1 HPmdash150 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash20 HP Windowed 25 HPmdash150 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash150 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash20 HP) Flanged (25 HPmdash150 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 2

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash150 HP) ⓯ Leg Stands Included (25 HPmdash150 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Options on pp 43mdash44 Warranty on pp 60mdash61

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

41 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash15 HP Windowed 15 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (20 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash10 HP) Flanged (15 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (75 HPmdash30 HP) ⓯ Leg Stands Included (15 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 240V VARIABLE TORQUE

NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP CIRCUIT BREAKER INCLUDES NAErsquos

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

5 HPmdash5 HP

75 HPmdash10 HP

15 HPmdash30 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

42 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect LSis S100 and iS7 Series Drives

5 HPmdash75 HP

10 HPmdash20 HP

25 HPmdash125 HP

LSis S100 and iS7 SUBMERSIBLE PACKAGE

1-PHASE to 3-PHASE 480V VARIABLE TORQUE

NEMA 3R ENCLOSURE

480V 12 HPmdash125 HP CIRCUIT BREAKER

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 3 For drive configuration utilizing sensorless vector control please contact us at 800-884-0404 for assistance

Options on pp 43mdash44 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 12 HPmdash125 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash125 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F 104deg F) (25 HPmdash125 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash125 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Drive Configured Utilizing VHz Control 3

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash125 HP) ⓯ Leg Stands Included (25 HPmdash125 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

43 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024

008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172

065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222

027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488

031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960

116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240

066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

156 LSis HMI eXP40-TTA Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $171720

052 Two Way Cellular Communication amp Functionality

061 Cloud Based Remote Monitoring

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940

151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592

155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

POTENTIOMETERS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

VFD

s

44 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

2000 SERIES LSIS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000

one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092

072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MODEL

NUMBERDESCRIPTION

VFD

s

45 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Siemens VFD Packages V20 G120X G120G130 Series

VFD

s

46 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP

CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

47 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

1 HPmdash10 HP

60 HPmdash200 HP

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

15 HPmdash50 HP

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❹ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot)

❿ Heavy Duty Lifting Ears (15 HPmdash700 HP)

⓫ Leg Stands Included (60 HPmdash400 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

48 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash40 HP FUSED w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Design for Maximum Cooling ❹ Combination Fused Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

49 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57

Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for General Purpose Application Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❹ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓫ Leg Stands Included (60 HPmdash200 HP) ⓬ Padlockable Door and Disconnect ⓭ Service Entry Rated ⓮ UL 508A Certified ⓯ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓰ Other Options Available

VFD

s

50 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens V20 Series Drives w BOP-2 Keypad

SIEMENS V20 ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash40 HP CIRCUIT BREAKER w THROUGH-DOOR

Standard Features for Base Model Include ❶ 1 HPmdash40 HP ❷ NEMA 4XmdashStainless Steel Enclosure ❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient ❹ Combination Circuit Breaker Disconnect Through-Door ❺ Easy-to-Use Drive for Basic Applications Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor ❼ Start Pushbutton ❽ Hand Off Auto (HOA) Selector Switch ❾ Potentiometer (Speed Pot) ❿ Padlockable Door and Disconnect ⓫ Service Entry Rated ⓬ UL 508A Certified ⓭ Standard Two (2) Year Warranty or OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓮ Other Options Available

Enclosure Air Conditioner Not Shown (25 HPmdash40 HP)

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

VFD

s

51 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor Options on pp 56mdash57 Warranty on pp 60mdash61

Standard Features for Base Model Include ❶ 1 HPmdash200 HP

❷ NEMA 4XmdashStainless Steel Enclosure

❸ Pre-Engineered for 32deg C90deg F IndoorNon-Direct Sunlight Ambient

❹ Combination Circuit Breaker Disconnect

Through-Door

❺ Easy-to-Use Drive for Basic Applications

Remote Start and Speed Control Capable with Analog Input Line Side Harmonic Filtering

❻ Surge Suppressor

❼ Start Pushbutton

❽ Hand Off Auto (HOA) Selector Switch

❾ Potentiometer (Speed Pot)

❿ Padlockable Door and Disconnect

⓫ Service Entry Rated

⓬ UL 508A Certified

⓭ Standard Two (2) Year Warranty or

OPTIONAL Three (3) Year Warranty w ldquoLightning amp Surgerdquo Protection

INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program

⓮ Other Options Available

VFDmdashEconomy Panel Economical Solutions for Washdown Duty Application Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

SIEMENS G120X ECONOMY PACKAGE

480V VARIABLE TORQUE NEMA 4X ENCLOSURE

RATED 32deg C90deg F INDOOR AMBIENT

480V 1 HPmdash200 HP CIRCUIT BREAKER w THROUGH-DOOR

Shown with Optional Floor Stands Enclosure AC Included (25 HPmdash200 HP)

VFD

s

52 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash700 HP

CIRCUIT BREAKER

1 HPmdash10 HP

60 HPmdash400 HP

15 HPmdash50 HP

Standard Features for Base Model Include ❶ 1 HPmdash700 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash700 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash400 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash700 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash700 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

53 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X IRRIGATION PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 1 HPmdash200 HP

FUSED

1 HPmdash10 HP

60 HPmdash200 HP

15 HPmdash50 HP

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashIrrigation Panel Special Purpose for Irrigation Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Fused Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

Standard Features for Base Model Include ❶ 1 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 1 HPmdash50 HP Windowed 60 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (60 HPmdash200 HP) ❺ Combination Fused Disconnect Through-Door (1 HPmdash50 HP) Flanged (60 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (15 HPmdash200 HP) ⓯ Leg Stands Included (60 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

VFD

s

54 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS V20 and G120 SUBMERSIBLE PACKAGE

240V VARIABLE TORQUE NEMA 3R ENCLOSURE

240V 12 HPmdash30 HP

CIRCUIT BREAKER

12 HPmdash3 HP

25 HPmdash30 HP

5 HPmdash20 HP

Standard Features for Base Model Include ❶ 12 HPmdash30 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash20 HP Windowed 25 HPmdash30 HP) ❹ Advanced Tunnel Design for Maximum Cooling (40deg C 104deg F) (25 HPmdash30 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (12 HPmdash20 HP) Flanged (25 HPmdash30 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering

❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance

❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (5 HPmdash30 HP) ⓯ Leg Stands Included (25 HPmdash30 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

Red = Fault

Blue = Backspin Mode

Green = Running

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor 2 G120 Series Drive Only

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens V20 and G120 Series Drives w BOP-2 Keypad Modular with Full Communication Package Design2

VFD

s

55 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIEMENS G120X SUBMERSIBLE PACKAGE

480V VARIABLE TORQUE NEMA 3R ENCLOSURE

480V 12 HPmdash200 HP

CIRCUIT BREAKER

12 HPmdash75 HP

50 HPmdash200 HP

10 HPmdash40 HP

Standard Features for Base Model Include ❶ 12 HPmdash200 HP Ratings in Stock ❷ Fully Gasketed NEMA 3R Heavy Duty Enclosure ❸ Door Mounted Keypad with Lockable Metal Cover (Solid 12 HPmdash40 HP Windowed 50 HPmdash200 HP) ❹ Advanced Tunnel Design for Maximum Cooling (45deg C 113deg F) (50 HPmdash200 HP) ❺ Combination Circuit Breaker Disconnect Through-Door (1 HPmdash40 HP) Flanged (50 HPmdash200 HP) ❻ Pre-Packaged Drive Solutions for Special Application

PID Loop Control Capable with Analog Input

Line Side Harmonic Filtering ❼ ldquoLightning amp Surgerdquo Protection Covering Momentary Anomaly Events

Line SidemdashLightning Surge and Severe Overvoltage

Load SidemdashSingle Phasing Phase Reversal and Voltage Unbalance ❽ 0mdash10 Minute Restart (Backspin) Timer ❾ 247 Programmable Timer ❿ Start Pushbutton ⓫ Hand Off Auto (HOA) Selector Switch ⓬ Potentiometer (Speed Pot) ⓭ High Visibility Status Light ⓮ Heavy Duty Lifting Ears (10 HPmdash200 HP) ⓯ Leg Stands Included (50 HPmdash200 HP) ⓰ Padlockable Door and Disconnect ⓱ Service Entry Rated ⓲ UL 508A Certified ⓳ Three (3) Year Warranty with ldquoLightning amp Surgerdquo Protection INCLUDING NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program ⓴ Other Options Available

sup1 HP ratings are for reference only Starter size is dependent on the nameplate Full Load Amps (FLA) rating of the motor

INCLUDES NAErsquos ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM

Options on pp 56mdash57 Warranty on pp 60mdash61

VFDmdashSubmersible Panel Special Purpose for Submersible Pump Application Pre-Engineered Pre-Packaged Drive Solutions Combination Circuit Breaker Disconnect Siemens G120X Series Drives w IOP-2 Keypad Infrastructure Pump Fan and Compressor Design

Red = Fault

Blue = Backspin Mode

Green = Running

VFD

s

56 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on p 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

004 Start Pushbutton $14904

005 Stop Pushbutton $14904

043 Start Stop Pushbutton $20412

007 Jog Pushbutton $14904

009 Raised Pushbutton - Specify Color and Function $14904

010 Flush Pushbutton - Specify Color and Function $16416

011 Mushroom Type Pushbutton - Specify Color and Function $22842

012 Illuminated Pushbutton - Specify Color and Function $30024008 Soft Start or VFD Chassis Reset Pushbutton $14904

006 Run Light $17172

013 Stop Light $17172

023 Power On Light $17172

014 Fault Light $17172

015 Ready Light $17172

016 Bypass Light $17172

017 Red Light - Specify Function $17172

018 Green Light - Specify Function $17172

019 Amber Light - Specify Function $17172

020 White Light - Specify Function $17172

021 Blue Light - Specify Function $17172

022 Push to Test Contact Assembly $17172065 High Visibility Status Light (PLC may required for complete functionality) $26892

024 Hand - Off - Auto HOA Selector Switch $21546

025 Local - Off - Remote Selector Switch $21546

026 Key Operated Hand - Off - Auto Selector Switch $35640

002 Two Position Selector Switch - Specify Function $17496

003 Three Position Selector Switch - Specify Function $21222027 Other Selector Switch - Specify Function and Type

032 1 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768033 10 Turn Potentiometer - (NEMA 3R NEMA 4 and NEMA 12) $15768

028 Ammeter $34452

029 Voltmeter $34452

030 Elapsed Time Meter $25488031 Other Power Metering - Specify Function

037 247 Programmable Timer $12960116 0-10 Minute Restart (Back Spin) Timer $16200

044 Door Mounted Keypad $27540

045 Lockable Metal Protective Cover (Solid) for Door Mounted Keypad $57240

055 Lockable Metal Protective Cover (Windowed) for Door Mounted Keypad $57240066 Plastic Protective Cover (NEMA 4XIP66) for Door Mounted Keypad $58320

110 Stack Tower Light - 360deg Visibility (Red Yellow Green) w 6 Cable $77760

040 Murphy Switch Interface W Fault Recall Function $172044

067 Siemens SIMATIC HMI TP 700 Touch Operation 7 Widescreen-TFT-Display3 (PLC Required) $272160

052 Two Way Cellular Communication amp Functionality

200 6AV21252GB030AX0 Siemens SIMATIC Mobile 2nd Generation HMI KTP700 Panel3 (PLC Required) $538920

201 6AV21252AE030AX0 SIMATIC HMI connection box compact for mobile panels $40824

202 6AV21815AG800AX0 Wall holder Type 13 for KTP700 mobile without attachment parts incl cable tray $28944

203 6AV21815AF020AX0 SIMATIC HMI connecting cable for mobile Length 2 m (656 ft) $35208

204 6AV21815AF050AX0 SIMATIC HMI connecting cable for mobile length 5 m (1640 ft) $43848

205 6AV21815AF080AX0 SIMATIC HMI connecting cable for mobile Length 8 m (2624 ft) $53568

206 6AV21815AF100AX0 SIMATIC HMI connecting cable for mobile length 10 m (3280 ft) $58752

207 6AV21815AF150AX0 SIMATIC HMI connecting cable for mobile Length 15 m (4921 ft) $70524

208 6AV21815AF200AX0 SIMATIC HMI connecting cable for mobile Length 20 m (6561 ft) $82296

209 6AV21815AF250AX0 SIMATIC HMI connecting cable for mobile Length 25 m (8202 ft) $88776061 Cloud Based Remote Monitoring

POTENTIOMETERS

MODEL

NUMBERDESCRIPTION

PUSHBUTTONS

PILOT LIGHTS

SELECTOR SWITCHES

METERS

TIMERS

OTHER DOOR MOUNTED OPTIONS

ADVANCED FAULT STATUS MONITORING OPTIONS

VFD

s

57 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

3 Additional information on pp 64

Please email salesnaemotorscom or contact us at 800-884-0404 for assistance

Motor Controls Panel Customization Made Easy

sup1 Multiplier Symbol 2 Warranty on pp 68mdash69

2000 SERIES SIEMENS - VARIABLE FREQUENCY DRIVE (VFD) - CONTROL PANEL OPTIONS M50sup1 LIST

PRICE (w Installation)

073 V20 Smart Access $19656

074 V20 BOP - Basic Operator Panel for V20 Drive $5616

075 BOP Interface - Connection between the V20 BOP and the V20 Drive $3348

076 BOP-2 - Basic Operator Panel for G120G130 Drive $7344

077 IOP - Intelligent Operator Panel for G120 Drive $38880080 AOP30 - Advanced Operator Panel for G130 Drive3

$196236

150 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $32940151 PROG-RELAY-LRE08RA240 - Expansion Module Programmable Relay $17820

152 PLC-6ES72121HE400XB0 - SIMATIC S7-1200 CPU 1212C - (Includes Power Supply Module) $56268

153 PLC-6ES72141HE400XB0 - SIMATIC S7-1200 CPU 1214C - (Includes Power Supply Module) $77004

154 PLC-6ES72231PH320XB0 - S7-1200 Expansion Module Digital Input $29592155 PLC-6ES72314HA300XB0 - SIMATIC S7-1200 CPU Analog Input $14148

100 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Black PUR Jacket 5 Meter $4320

101 4-Wire Micro DC Cord Set Straight Connector Coupling Nut Gray PUR Jacket 10 Meter $4860

102 Pressure Transducer 0 - 100 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

103 Pressure Transducer 0 - 200 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

104 Pressure Transducer 0 - 250 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000

105 Pressure Transducer 0 - 500 PSI 4-Pin Micro DC Connector (Transducer Cord Required eg Option 100 or 101) $54000106 Level Transducer $162000

- We Stock Fuses (including VFD High Speed) for Convenience Please Call for Pricing

034 Space Heater with Thermostat $46008

054 Transformer $16092

041 Surge Suppressor $33156

115 SymCom MotorSaverreg Model 460 $22032

064 dV dT Filters

062 IEEE 519 Passive Harmonic Filter

063 Lightning and Surge Protection2 - All panels will include line side lightning surge and severe overvoltage protection which comprises $135000one (1) additional year of warranty coverage on the entire panel In addition all soft starter amp VFD panels will include load side single phasing

phase reversal and voltage unbalance protection and are eligible for NAEs No Hassle Chassis Exchange Program

070 Main Line Only Box 20 Tall 16 Wide 12 Depth $194292

071 Main Line Only Box 20 Tall 20 Wide 12 Depth $259092072 Main Line Only Box 20 Tall 24 Wide 12 Depth $604692

SPFSK-1212-W 2 Legs 12 Tall 12 Depth $24084

SPFSK-1214-W 2 Legs 12 Tall 14 Depth $27000

SPFSK-1216-W 2 Legs 12 Tall 16 Depth $27000

SPFSK-1220-W 2 Legs 12 Tall 20 Depth $29808

SPFSK-1224-W 2 Legs 12 Tall 24 Depth $32400

SPFSK-624-W 2 Legs 6 Tall 24 Depth $32400

SPFSK-1212-N4X 2 Legs 12 Tall 12 Depth NEMA 4X 304 Stainless Steel $91368

SPFSK-1218-N4X 2 Legs 12 Tall 18 Depth NEMA 4X 304 Stainless Steel $109512SPFSK-1224-N4X 2 Legs 12 Tall 24 Depth NEMA 4X 304 Stainless Steel $115452

PROTECTION MECHANISMS

MAIN LINE ONLY BOXES

FLOOR STANDS

PROGRAMMABLE RELAY OPTIONS

PROGRAMMABLE LOGIC CONTROLLERS (PLC) OPTIONS

SENSOR OPTIONS

FUSES

SPACE HEATERS

MISCELLANEOUS

SIEMENS DRIVE CHASSIS OPTIONS

MODEL

NUMBERDESCRIPTION

VFD

s

58 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

SIMATIC AOP30 Advanced Operator Panel The user-friendly AOP30 operator panel is an optional inputoutput device for SINAMICS G130 convertors The operator panel can be used for commissioning operation and diagnostic purposes

VFDmdashControl Options CONTROL OPTIONS

Data sheet 6SL3055-0AA00-4CA5 AOP30 KEY FEATURES DISPLAY WITH GREEN BACKLIGHTING RESOLUTION 240 X 64 PIXELS MEMBRANE KEYBOARD WITH 26 KEYS CONNECTION FOR A 24V POWER SUPPLY TIME AND DATE MEMORY WITH INTERNAL BATTERY BACKUP 4 LEDs TO INDICATE THE OPERATING STATUS OF THE DRIVE

ADVANCED OPERATOR PANEL

Data sheet 6AV2124-0GC01-0AX0 SIMATIC HMI TP700 COMFORT COMFORT PANEL TOUCH OPERATION 7 WIDESCREEN-TFT-DISPLAY 16 MIL COLORS PROFINET INTERFACE MPIPROFIBUS DP INTERFACE 12 MB USER MEMORY WINDOWS CE 60 CONFIGURABLE FROM WINCC COMFORT V11

HUMAN MACHINE INTERFACE PANEL

SIMATIC HMI TP700 Comfort Panel For operator control and monitoring SIMATIC HMI products are ldquostate of the artrdquo They are the intelligent response to increasingly complex processes and stringent requirements for the operation of machines and plants They feature state-of-the-art technology outstanding performance as well as integrated functionality from size 7rdquo or larger The new SIMATIC HMI Comfort Panels are seamlessly integrated in the TIA Portal via WinCC This innovative engineering framework represents the key to the full performance capacity of Totally Integrated Automation

Data sheet 6AV2125-2GB03-0AX0 MOBILE 2ND GENERATION HMI PANEL

SIMATIC HMI KTP700 MOBILE 70 TFT DISPLAY 800x 480 PIX-EL 16m COLORS KEY AND TOUCH OPERATION 8 FUNCTION KEYS 1x PROFINETINDUSTRIAL ETHERNET INTERFACE 1x MULTIMEDIA CARD 1x USB CONFIGURABLE FROM WINCC COMFORT V13 SP1

SIMATIC HMI KTP700 Mobile 2nd Gen Panel SIMATIC HMI Mobile Panels 2nd generation offer even more performance flexibility convenience and quality mdash making operation and monitoring even safer and more efficient They transfer the functionality and performance of SIMATIC HMI Comfort Panels to mobile control units Users benefit from more flexibility and convenience They are ideally suited for small machines with small footprints The compact connection box is easily mounted directly onto the control cabinet

SIMATIC BOP-2 Basic Operator Panel The BOP-2 Basic Operator Panel can be used to commission drives monitor drives in operation and input individual parameter settings

Data sheet 6SL3255-0AA00-4CA1 BOP-2 KEY FEATURES LCD MONOCHROME DISPLAY WITH GREEN BACKLIGHTING

BASIC OPERATOR PANEL (BOP-2)

SIMATIC IOP-2 Intelligent Operator Panel The IOP-2 supports both newcomers and drive experts Thanks to the membrane keyboard with a central sensor control field high-contrast color displays menu-based operation and application wizards it is easy to commission drives A drive can be essentially commissioned without having to use a printed parameter list ndash as the parameters are displayed in plain text and explanatory help texts and the parameter filtering function are provided

Data sheet 6SL3255-0AA00-4JA2 IOP-2 KEY FEATURES HIGH-CONTRAST COLOR DISPLAY 320 X 240 PIXELS MEMBRANE KEYBOARD WITH CENTRAL SENSOR CONTROL

INTELLIGENT OPERATOR PANEL (IOP-2)

VFD

s

59 naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

VFDmdashSpecial Enclosure Feature NEMA 3R Only

53rdquo AND UP ADVANCED TUNNEL DESIGN

SPECIAL FEATURE

40deg C104deg F VT 50deg C122deg F CT NEMA 3R ONLY

53 Height and Up Enclosures 40deg C 104deg F VT 50deg C 122deg F CT (V20and G120)

45deg C 113deg F VT and CT (G120X)

Significantly Reduces Contaminants

Advanced Tunnel Design for Maximum Cooling

Patent Pending

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR CONTROLS WARRANTY POLICY amp PROCEDURES North American Electric Inc warrants to that all products will conform to final specifications andor drawings and will be free from defects in materials and workmanship Special build panels will require the final specifications and drawings to be approved in writing by the Buyer before being released for production The warranty shall remain in effect for a period specified for each product line (24 36 or 60 months) from the date of the invoice See warranty period for each product line below

CHASSIS Soft Start Chassis Siemens Soft Starter Chassis24 months from date of invoice ndash 3RW30 Series 3RW40 Series 3RW44 Series

Variable Frequency Drive Chassis LSis VFD Chassis24 months from date of invoice ndash C100 Series S100 Series S100-4X Series H100 Series iS7 Series Siemens VFD Chassis24 months from date of invoice ndash V20 Series G120 Series G120X Series G130 Series

ENCLOSED PANEL PACKAGES Safety Switches ATLs and PWS Panels Heavy Duty Safety Switches24 months from date of invoice Heavy Duty Safety Switches with ldquoLightning amp Surgerdquo Protection36 months from date of invoice Across the Line Starter Panels24 months from date of invoice Part Wind Starter Panels24 months from date of invoice

Reduced Voltage Soft Starter Panels General Purpose amp Washdown Duty Soft Starters24 months from date of invoice ndash Normal Duty and Heavy Duty SAF CrusherUltra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs) SAF Ultra Heavy Duty Soft Starters60 months from date of invoice (SAF Opal Pro M6 Series Warranty Includes SCRs)

Variable Frequency Drive Panels General Purpose amp Washdown Duty ndash Non-Combo amp Economy Panel Pkg24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose amp Washdown Duty ndash Standard Panel Packages24 months from date of invoice ndash Variable Torque and Constant Torque General Purpose ndash Integrator Packages24 months from date of invoice ndash Variable Torque and Constant Torque Special Purpose ndash Irrigation Pump Panel Packages36 months from date of invoice with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Positive Displacement Pump Panel Packages36 months from date of invoice Standard Advanced and Deluxe Panel Packages with ldquoLightning amp Surgerdquo Protection

INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program Special Purpose ndash Beam Pump Panel Package36 months from date of invoice with ldquoLightning amp Surgerdquo Protection INCLUDING ldquoNo Hasslerdquo Chassis Exchange Program

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

Special Purpose ndash Custom Build To Order Panel Packagehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip36 months from date of invoice

(Customer must review approve and sign drawings prior to panel being released for production)

Parts replaced or repaired in the warranty period shall carry the full warranty the balance of the equipment will carry the unexpired portion of the original warranty The liability of the Seller hereunder is limited to replacing or repairing any part or parts which are defective or do not conform to such specifications and drawings provided that such part or parts are returned within ninety (90) days from the date such defect is discovered The Seller shall have the sole right to determine if the parts are to be repaired at the job site or whether they are to be returned to the Sellerrsquos facility for repair or replacement If the Seller has determined warranty part or parts are to be repaired at the job site a purchase order must be issued for traveling and living expenses All items returned to Seller for repair or replacement must be accompanied by an RMA number with all the necessary information required by the Seller Shipping charges for incoming part or parts to be repaired or replaced will be at the Buyerrsquos expense The above conditions must be met if warranty is to be valid Seller will not be liable for any damage done by unauthorized repair work unauthorized replacement parts from any misapplication of the product or for damage due to accident abuse or act of God Seller makes no warranties express or implied including any warranty as to merchantability or fitness for a particular use Seller is not liable for and Purchaser waives any right of action it has or may have against seller for any consequential or special damages arising out of any breach of warranty and for any damages Purchaser may claim for damage to any property or injury or death to any person arising out of its purchase or the use operation or maintenance of the product Seller will not be liable for any labor subcontracted or performed by Purchaser for preparation of warranted item for return to Sellerrsquos facility or for preparation work for field repair or replacement Invoicing of Seller for labor either performed or subcontracted by Purchaser will not be considered as a liability by the Seller North American Electricrsquos liability under this warranty or any other warranty whether expressed or implied in law or fact shall be limited to the repair or replacement of defective material and workmanship and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight

ldquoLIGHTNING amp SURGErdquo PROTECTION NAErsquos Heavy Duty Safety Switches and VFD Special Purpose Panel Packages include this protection as a standard feature but it may also be purchased separately All panel packages which receive this protection will include line side lightning surge and severe overvoltage protection and will comprise of one (1) additional year of warranty coverage on the entire panel In addition all Soft Starter amp VFD panel packages which receive this protection will include load side single phasing phase reversal and voltage unbalance protection and are eligible for NAErsquos ldquoNo Hasslerdquo Chassis Exchange Program NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lightning strikes to the motor control panel The panel must be properly grounded

ELECTRIC MOTOR CONTROLS WARRANTY PROCEDURE

Step 1 Have the motor control inspected by an authorized service shop to determine if the problem is a result of defects in materials andor workmanship If the problem is a result of defects in materials andor workmanship North American Electric Inc will pay a reasonable inspection fee for the inspection that will included a written warranty report that describes the cause of failure along with photographs that show in detail what is described in the warranty report

Step 2 Contact our warranty department and be prepared to provide the following information and documentation

1) Serial Number 2) Model Number 3) Inspection Failure Report 4) Photographs showing the cause of failure 5) Estimated cost of repair

Step 3 Our warranty department will determine whether to replace or repair the defective product DO NOT repair any product without prior written purchase order from North American Electric Inc Always be sure to take clear photographs before beginning any repair work

Visit our website at wwwnaemotorscom for detailed information and instructions on the following

1) Freight Damage and Claims Policy and Procedure 2) Return Material Authorization (RMA) Policy and

Procedure

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY

WITH

ldquoLIGHTNING amp SURGErdquo PROTECTION

Terms amp Conditions of Sale

ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM North American Electricrsquos (aka NAE) ldquoNo Hasslerdquo Chassis Exchange Program is a revolutionary motor control panel warranty designed to keep you up and running Our ldquoNo Hasslerdquo Chassis Exchange Program makes it easy to exchange your Soft Starter or VFD chassis without needlessly having to purchase a chassis while at the same time minimizing unplanned downtime Should your Soft Starter or VFD panelrsquos chassis fail NAE will promptly ship a new or refurbished chassis for the duration of your selected warranty Your entire panel is further protected with our three (3) year ldquoBumper to Bumperrdquo coverage even protecting against line side anomalies such as lightning surges and severe overvoltage events and load side anomalies such as single phasing phase reversal and voltage unbalance Your panel must be installed by an NAE Authorized or Certified Installer to qualify ldquoNO HASSLErdquo CHASSIS EXCHANGE PROGRAM WARRANTY with ldquoLIGHTNING amp SURGErdquo PROTECTION Soft Starter and VFD panel packages must include ldquoLightning amp Surgerdquo Protection to be eligible for our ldquoNo Hasslerdquo Chassis Exchange Program Warranty As an option you can purchase ldquoLightning amp Surgerdquo Protection (LIST Price = $949) which will automatically include our ldquoNo Hasslerdquo Chassis Exchange Program Warranty on any Soft Starter or VFD panel packages

ldquoLightning amp Surgerdquo Protection ldquoLightning amp Surgerdquo Protection covering momentary anomalies such as

Line side events lightning surges and severe overvoltage Load side events single phasing phase reversal and voltage unbalance

NOTE This protection is not designed to withstand nor does it cover load side (downstream) lightning strikes or direct lighting strikes to the motor control panel The panel must be properly grounded

The ldquoNo Hasslerdquo Chassis Exchange Program Warranty must be activated (See ldquoObligations of the Customerrdquo) If the panel is installed by a North American Electric Authorized Installer then the warranty period shall be three (3) years from the date of delivery If the panel is installed by a North American Electric Certified Installer then the warranty period shall be three (3) years from the date of installation NAE Certified Installers have six (6) months from the date of delivery to commission the control panel otherwise the warranty period shall be three years from the date of delivery Our Chassis Exchange Program Warranty benefits include ldquoBumper to Bumperrdquo coverage of the entire panel package from 0 ndash 36 months from date of delivery Repair replacement or credit of a panel package that is found to be defective due to faulty manufacture design

andor defective materials Factory installed options sold with the panel package Cost of replacement parts or replacement of the chassis Cost of labor for repair work ldquoLightning amp Surgerdquo Protection covering momentary anomaly events

Line Side Lightning Surge and Severe Overvoltage Load Side Single Phasing Phase Reversal and Voltage Unbalance

ldquoNo Hasslerdquo Chassis Exchange Program offering same day shipment of exchanged chassis (Next Day Air Second Day Air and Hot Shot Service are available for an additional charge)

OPTIONAL EXTENDED WARRANTIES You may purchase and extend your panelrsquos aforementioned ldquoNo Hasslerdquo Chassis Exchange Program warranty to provide additional protection for up to six (6) years by selecting one of the following

Extended Warranty for the ldquoChassis Onlyrdquo An Extended Warranty for the Chassis Onlyrdquo may be implemented providing up to six (6) years of coverage from the date of purchase by adding 3 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

Extended ldquoBumper to Bumperrdquo Warranty for the Entire Panel An Extended ldquoBumper to Bumperrdquo Warranty for the entire panel may be implemented providing up to six (6) years of coverage from the date of purchase by adding 5 of the total purchase price of the panel per year for years four (4) five (5) and six (6)

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

OBLIGATIONS OF THE CUSTOMER NAErsquos revolutionary ldquoNo Hasslerdquo Chassis Exchange Program with Lightning amp Surge Protection is intended for Soft Starter and VFD panels which can be shipped to and repaired utilizing our authorized chassis repair facility (See ldquoNo Hasslerdquo Chassis Exchange Program Claim Procedures) The customer is required to have an Authorized or Certified Installer activate this warranty by following our ldquoStart Up and Installation Requirementsrdquo

Start Up and Installation Requirements The Soft Starter and VFD panel must be installed by a NAE Authorized or Certified Installer A NAE Chassis Exchange Program Installation Form must be filled out and submitted to North American Electric Inc within fifteen (15) days from the date the panel is installed and prior to any claim or the ldquoNo Hasslerdquo Chassis Exchange Program Warranty with ldquoLightning amp Surgerdquo Protection is considered void Certified Installer classes are offered in Hernando Mississippi You can find updated information on the following topics at the link listed below

How to become a NAE Authorized Installer How to become a NAE Certified Installer NAE Chassis Exchange Program Installation Form NAE University Class Schedule

wwwnaemotorscomchassisexchangeprogram

ldquoNo Hasslerdquo Chassis Exchange Program Claims Procedures What You Must Do 1) Contact North American Electric Inc and open a claim for your failed Soft Starter or VFD chassis Refer to our

ldquoElectric Motor Controls Warranty Claim Procedurerdquo 2) Issue a purchase order for a replacement Soft Starter or VFD chassis 3) Return the defective chassis to North American Electric Inc for warranty inspection 4) If the failure is due to defective materials andor workmanship then NAE will credit you for the replacement

chassis 5) If the failure is not due to defective materials andor workmanship then you will be responsible for payment of

the replacement invoice WARRANTY EXCLUSIONS

1) Any loss or damages caused by an improperly grounded panel 2) Any loss or damages caused by a defective product 3) Any costs and expenses resulting from onsite repair 4) Travel costs and expenses resulting from onsite repair 5) Dismantling installation or commissioning of the product 6) Defects caused by normal wear and tear or external factors such as

a Incorrect grounding of the panel b Incorrect installation c Incorrect operation and maintenance d Improper connection to peripheral or third party products e Use of unauthorized spare parts f Modification or repair performed by a person not authorized by North American Electric Inc g Natural disaster h Connection to irregular voltage sources i Operation outside the usage of parameters stated in the userrsquos manual j Lightning amp Surge Protection that is disabled

7) Peripheral items and options not purchased with the drive 8) Cost of freight to ship product from installation to North American Electric Inc repair facility and back 9) Customs duties and taxes

This ldquoNo Hasslerdquo Chassis Exchange Warranty Protection is being offered by North American Electric Inc The manufacturer of the chassis is not liable for any claims made under this warranty All claims should be made directly with North American Electric Inc

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

MOTOR WARRANTY POLICY amp PROCEDURES NO‐FAULT WARRANTY POLICY

Motors with frame sizes 215T and smaller are covered under our ldquoNo‐Fault Warrantyrdquo The warranty period is 24 months from the date of invoice This special limited warranty is offered one time per end‐user per application If there is more than one failure please follow our standard limited warranty policy and procedure and contact our warranty department for assistance For information regarding this warranty policy you may contact our customer service department at (800) 884‐0404 or visit our website at wwwnaemotorscom North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our ldquoNo Fault Warrantyrdquo you must provide the following documentation to ensure your claim is processed in a timely manner

Original nameplate from the failed motor Copy of the original North American Electric Inc invoice or the invoice number for the failed motor A brief description of the failure for quality control purposes

Note Please make a legible photo copy of the nameplate from the failed motor for your records

STANDARD LIMITED WARRANTY POLICY

General Purpose Cast Iron Motors (TEFC amp ODP)helliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice General Purpose Aluminum Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Rolled Steel Motors Single Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceRolled Steel Motors Three-Phasehelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceCrusher Duty Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice Stainless Steel Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceClose Coupled Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceExplosion Proof Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceOil Well Pump Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoiceVertical Hollow Shaft Motorshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip24 months from date of invoiceRotary Phase Convertershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceShaft Mount Reducershelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 24 months from date of invoiceMotor Slide Baseshelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphelliphellip 36 months from date of invoice

North American Electric Inc shall at its option and expense either repair or replace any such motor or part which is defective within the warranty period To be covered under warranty any motor must have at all times been operated or used under normal operating conditions for which the motor was designed In the event of warranty claims North American Electric Inc must be notified promptly following any motor failure The motor should be sent to a North American Electric Inc authorized service center to diagnose cause of failure After this examination a determination will be made if the failure was due to defective material andor workmanship If the failure was due to defective material andor workmanship North American Electric Inc will replace or repair the motor DO NOT repair any motor without a prior written purchase order from North American Electric Inc North American Electricrsquos liability under this warranty or any other warranty expressed or implied in law or fact shall be limited to the replacement of the motor and in no event shall North American Electric Inc be liable for consequential or indirect damages including freight When filing a claim under our standard Limited Warranty Policy please be prepared to provide the following

1) Serial Number 2) Model Number 3) EASA Report 4) Photographs showing the cause of failure 5) Estimated cost of repair 6) Nameplate (photo of nameplate for stainless steelwashdown duty motors) if motor is to be replaced

For more information about warranty policies and procedures please contact our customer service department at (800) 884‐0404 visit our website at wwwnaemotorscom or send us an email at salesnaemotorscom

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

NAE University offers professional com-

prehensive and educational programs in-

cluding

SalesProduct Training Motors Controls

Motor Start Up Basic Programming of Low Voltage AC Drives

Maintenance and Troubleshooting Training

Motors Controls

We provide in depth hands on training at

our headquarters in Hernando Mississippi

We also provide on-site training at your

location as well as internet courses and

webinars

For more information please visit our

website at wwwnaemotorscom or

contact us at 800-884-0404

CONTINUING EDUCATION

CONTINUING EDUCATION

North American Electricrsquos continuing education courses were created with you in mind to provide information tools technical support and training to sell install and support low voltage AC drives

naemotorscom 8008840404 copy 2021 North American Electric Inc LIT450AGCAT Agricultural Catalog - Electric Motors and Controls - 092021

8008840404 salesnaemotorscom

naemotorscom PO Box 130 350 Vaiden Drive

Hernando MS 38632

General Purpose Motors amp More

508A Certified

Page 17: alog - naemotors.com
Page 18: alog - naemotors.com
Page 19: alog - naemotors.com
Page 20: alog - naemotors.com
Page 21: alog - naemotors.com
Page 22: alog - naemotors.com
Page 23: alog - naemotors.com
Page 24: alog - naemotors.com
Page 25: alog - naemotors.com
Page 26: alog - naemotors.com
Page 27: alog - naemotors.com
Page 28: alog - naemotors.com
Page 29: alog - naemotors.com
Page 30: alog - naemotors.com
Page 31: alog - naemotors.com
Page 32: alog - naemotors.com
Page 33: alog - naemotors.com
Page 34: alog - naemotors.com
Page 35: alog - naemotors.com
Page 36: alog - naemotors.com
Page 37: alog - naemotors.com
Page 38: alog - naemotors.com
Page 39: alog - naemotors.com
Page 40: alog - naemotors.com
Page 41: alog - naemotors.com
Page 42: alog - naemotors.com
Page 43: alog - naemotors.com
Page 44: alog - naemotors.com
Page 45: alog - naemotors.com
Page 46: alog - naemotors.com
Page 47: alog - naemotors.com
Page 48: alog - naemotors.com
Page 49: alog - naemotors.com
Page 50: alog - naemotors.com
Page 51: alog - naemotors.com
Page 52: alog - naemotors.com
Page 53: alog - naemotors.com
Page 54: alog - naemotors.com
Page 55: alog - naemotors.com
Page 56: alog - naemotors.com
Page 57: alog - naemotors.com
Page 58: alog - naemotors.com
Page 59: alog - naemotors.com
Page 60: alog - naemotors.com
Page 61: alog - naemotors.com
Page 62: alog - naemotors.com
Page 63: alog - naemotors.com
Page 64: alog - naemotors.com
Page 65: alog - naemotors.com
Page 66: alog - naemotors.com