AC Power - - - Normal Range: 120VAC 50/60Hz Operating Range: 108~132 VAC, 50/60Hz
Power Consumption
168W (Incl. 4 ODUs) 27W 48W (Incl. 2
DOUs) 390W (Incl. 6 RDUs) 78W (Incl. VHF/UHF RDU)
Operating Temp 14 to 122°F, -10 to +50°C 13 to 131°F, -25 to +55°C
Operating Humidity - 0% to 90% (Non-condensing)
Mechanical Product Description Size (Inches) W x H x D Weight (lbs) Power Consumption
BIU Chassis (VHF/UHF Inputs Standard) 19 x 8.72 (5U) x 17.7 49.2 88W 700MHz LTE Full Band SISO MDBU
1.57 x 5.5 x 10.96
6.82 12W 700MHz LTE Full Band MIMO MDBU 7.04 19W 800MHz & 900MHz MDBU 6.82 20W 850MHz & 700MHz MDBU (Public Safety) 7.04 19W 850MHz & 700MHz LTE Full Band 7.04 19W 1900 MHz MDBU 6.82 20W 1900 MHz MDBU B Path 6.82 20W 2100 MHz MDBU 6.82 12W 2100 MHz MDBU B Path 6.82 12W Blank BIU Module 0.88 - ODU Chassis 19 x 1.75 (1U) x 17.7 12.56 3W OEU Chassis 19 x 3.46 (2U) x 17.7 20.5 12W 4 Port and 1 Port Optical Module (for ODU / OEU) 11.8 x 5.6 x 1.1 3.52 10W Blank Optical Module (for ODU and OEU) 11.8 x 5.6 x 1.1 0.88 - MROU Chassis - AC Power *Fully Loaded 9.84 x 15.94 x 44.14 130 390W MROU Chassis - DC Power *Fully Loaded 9.84 x 15.94 x 44.14 130 390W Add-on remote (AOR) for ROU - AC or DC Power (Required for VHF/UHF Services) 19 x 6.96 (4U) x 10.16 24.25 78W
Standards and Certifications
Specification Description
NFPA 72 Code Compliant National Fire Alarm Code. Applicable for components that can be installed outdoors (e.g., Remote Optic Units and Add-On Remotes).
NEMA 4 This equipment meets NEMA 4 enclosure standards to withstand rain, sleet, snow, dust, dirt, splashing water, and hose-directed water. (Applies only to Remote Optic Units and Add-On Remotes.)
UL (North America) UL 60950-1, 2nd Edition CSA C22.2 No. 60950-1-07, 2nd Edition, CSA C22.2 No. 60950-1-03, 1st Edition
FCC (North America) FCC Part24 Subpart D and Part90 Subpart I FCC Part22 Subpart H and Part 27 Subpart C FCC Part24 Subpart E and Part 27 Subpart C
IC (Canada) RSS-131 (ISSUE 2), ICES-003 Emissions (North America) FCC Part15 Subpart B, Class A MTBF (Telecordia SR-332 Issue2)
Failure Rate = 11,823 MTBF = 9.65 Years
ALLIANCE DAS – 5W Remote Optic Unit (MROU) Product Specification
Part Numbers Product Description Part Number BIU (Base Station Interface Unit) Signal Source Inputs
Base Station Interface Unit **NOTE: Input Power -48VDC. Power supply not included. BIU_C BIU Combiner (Doubles Input Modules on Single Fiber Strand) BIU_Combiner Blank BIU Module for the BIU BIU_B (BIU Blank) 1900 MHz Input Module for the BIU MDBU_1900P 1900 MHz Input Module for the BIU; B Path for MIMO MDBU_1900P_B 700MHz LTE Full Band MIMO Input Module for the BIU MDBU_700LTE_M 700MHz LTE Full Band SISO Input Module for the BIU MDBU_700LTE_S 800MHz & 900MHz Input Module for the BIU MDBU_800PS_900I_PA 850MHz & 700MHz LTE Full Band Input Module for the BIU MDBU_850C_700FB 850MHz & 700MHz (first responder) Input Module for the BIU MDBU_850C_700PS 2100MHz Input Module for the BIU MDBU_AWS 2100MHz Input Module for the BIU; B Path for MIMO MDBU_AWS_B ALLIANCE Power Supply - 48 VDC / 480 W RMP_480 ODU/OEU Optical Distribution and Expansion Units Optical Distribution Unit Chassis ODU_C Optical Expansion Unit Chassis **NOTE: Input Power -48VDC. Power supply not included. OEU_C 1 Port Optical Module (For TITAN use only) ODU_OM_1 / OEU_OM_1 4 Port Optical Module (For TITAN and ALLIANCE) ODU_OM_4 / OEU_OM_4 Blank Optical Module for the ODU ODU_B / OEU_B MROU and RDU (Mid-Power Remote Optic Unit and Remote Distribution Units) 5 Watt Remote Optical Unit Chassis - AC Power / DC Power MROU_C_M_AC / MROU_C_M_DC 5 Watt Blank Module MROU_B Add-on cabinet for ROU (AOR) - AC Power / DC Power (Required for VHF/UHF Services) ROU_Add-On_AC / ROU_Add-On_DC 5 Watt 1900MHz Amplifier Module MRDU_1900P 5 Watt 700MHz LTE Full Band Amplifier Module MRDU_700LTEF 5 Watt 700MHz LTE Full Band Amplifier Module; B Path for MIMO MRDU_700LTEF_B 5 Watt 700MHz & 800MHz Public Safety Amplifier Module MRDU_700PS_800PS 5 Watt 800MHz iDEN & 850MHz Cellular Amplifier Module MRDU_800I_850C 5 Watt 850MHz Full Band Amplifier Module MRDU_850C 5 Watt 900MHz Amplifier Module MRDU_900I 5 Watt 2100MHz Amplifier Module MRDU_AWS 5 Watt 2100MHz Amplifier Module; B Path for MIMO MRDU_AWS_B 150MHz VHF & 450MHz UHF Amplifier Module RDU_150_450 380MHz VHF & UHF Amplifier Module (Military Band) RDU_E_VHF_UHF Combiner – Required for combining output for 700LTE / 2100AWS MIMO MROU_CU_70B21B Combiner – Required for combining output for 700PS/800PS/900i MROU_CU_708090 DMS (Data Management System) Data Management System (DMS) for ALLIANCE DMS_1200 REL6
SOLiD 617 North Mary Avenue Sunnyvale, CA 94085 PHONE: 888.409.9997 EMAIL: [email protected] WEB: www.solid.com