Top Banner
NPI Sept 2007 Please contact your local marketing center for latest information Confidential. For internal use only 1 All you need to know about MP2/X2 Prepared by Enzo Park, Daniel Cho Product Manager Patient Monitoring Systems CONFIDENTIAL Division, Author, MMMM dd, yyyy, Reference Agenda • MP2 Vs X2 – the difference • How to order –What is Included –Core features Vs Options • Mountings & Accessories • Printing Solutions • Respironics CO2
26

All you need to know about MP2 4sept07 - Philips

Nov 02, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 1

All you need to know about MP2/X2

Prepared by Enzo Park, Daniel ChoProduct ManagerPatient Monitoring Systems

CONFIDENTIAL Division, Author, MMMM dd, yyyy, Reference

Agenda

• MP2 Vs X2 – the difference• How to order

–What is Included–Core features Vs Options

• Mountings & Accessories• Printing Solutions • Respironics CO2

Page 2: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 2

CONFIDENTIAL 3Division, Author, MMMM dd, yyyy, Reference

IntelliVue FamilyIntelliVue Family

CONFIDENTIAL 4Division, Author, MMMM dd, yyyy, Reference

MP2 / X2 – IntelliVue Family

MP2MP2 X2X2

Page 3: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 3

CONFIDENTIAL 5Division, Author, MMMM dd, yyyy, Reference

Intended UseIntended Use

CONFIDENTIAL 6Division, Author, MMMM dd, yyyy, Reference

MP2 – Low End Monitor

• Standalone patient monitor

M8102AM8102A

Page 4: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 4

CONFIDENTIAL 7Division, Author, MMMM dd, yyyy, Reference

X2 – New MMS Generation• Processing unit and display in a single package• Can be used as an MMS or as a standalone patient monitor

M3002AM3002A

CONFIDENTIAL 8Division, Author, MMMM dd, yyyy, Reference

FeaturesFeatures

Page 5: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 5

CONFIDENTIAL 9Division, Author, MMMM dd, yyyy, Reference

X2 – MP2

3,5’’color TFT-

displaywith Touch

188 x 99 x 86 mm7.4 x 3.9 x 3.4 in

1.2 kg (2.7 lbs)

CONFIDENTIAL 10Division, Author, MMMM dd, yyyy, Reference

X2 – MP2

You can usea pen

to operatethe screen

Page 6: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 6

CONFIDENTIAL 11Division, Author, MMMM dd, yyyy, Reference

X2 – MP2

Rugged design

1 meter drop test

INTERNAL USE ONLY 12PMD, Martin Allgeier, Fall 2007

X2 – MP2 Profile Outdoor*

X2/MP2 onlyX2/MP2 only

VolumeWhite Colors

*Screenshots in Demo Mode

• For use in typical outdoor conditions

– bright sunlight– higher ambient

noise

Brightness

Page 7: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 7

INTERNAL USE ONLY 13PMD, Martin Allgeier, Fall 2007

Green FlagshipGreen Flagship

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

EcoDesign Summary Patient Monitor MP2/X2

Guess what progress...!

Page 8: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 8

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

Improvements MP2 vs. M3Actual Target

• Weight: 1.2 kg vs. 2.65 kg 1) - 55% - 30% 2)

• Energy: 4.5 W vs. 12.5 W 1) - 64% - 50% 2)

• Packaging: 1.1 kg vs. 1.58 kg - 30% - 25%

• Hazardous materials: no BeCu contact springs used

EcoDesign Summary Patient Monitor MP2/X2

The 1st PMS Product to carry this Logo!

INTERNAL USE ONLY 16PMD, Martin Allgeier, Fall 2007

X2 versus MP2X2 versus MP2

Page 9: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 9

INTERNAL USE ONLY 17PMD, Martin Allgeier, Fall 2007

X2 versus MP2

1.5 kg (3.3 lbs)Weight

StandardTouch screen

3.5"TFT QVGA (320 x 240 pixels)Display

MP2X2Options Features

16 P, 4h@12s, 24h@1min, 48h@5min(no extended database)Trend

StandardTabular and Graphic Trend

3 WavesWaveforms

INTERNAL USE ONLY 18PMD, Martin Allgeier, Fall 2007

X2 versus MP2

n/aMasimo®Optional SpO2 Algorithm

StandardConnectivity to Extensions

Respironics ® mainstream/sidestreamCO2 Technology

(IBP+Temp) or CO2Optional Measurement

ECG - SpO2 - NBPBasic Measurement

MP2X2Options Features

Optional

OptionalStandardST Map

StandardECG Sync Pulse Output

OptionalConventional 12 lead

StandardEASI 12 lead

StandardFull Arrythmia

StandardBasic Arrythmia

Page 10: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 10

INTERNAL USE ONLY 19PMD, Martin Allgeier, Fall 2007

X2 versus MP2

n/aStandardCompanion Mode

Via PC or PIICReports

OptionalITS Network (Smart Hopping) 1.4/2.4 GHz

OptionalStandardNetwork to PIIC

StandardNetwork to PC

MP2X2Options Features

StandardMMS mount

StandardAnti-slip Pad

3 hrsBattery Life

StandardBattery

StandardOptionalPower Supply with Network

StandardOptionalHandle

INTERNAL USE ONLY 20PMD, Martin Allgeier, Fall 2007

MeasurementsMeasurements

Page 11: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 11

INTERNAL USE ONLY 21PMD, Martin Allgeier, Fall 2007

X2 – MP2 Measurements

Standard1. ECG/Resp2. SpO2 FAST– X2:

• FAST or• Masimo ®

3. NBP

Optional4. Temp 5. IBP

OR6. CO2 X2 MP2

INTERNAL USE ONLY 22PMD, Martin Allgeier, Fall 2007

X2 Measurement OptionsStandard

ECG/RespSpO2 FAST

• FAST #A01• Masimo® #A03

NBP

Optional Temp/IBP #C06

Temp AND IBP

OR

#C14CO2 Ready

X2

Page 12: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 12

INTERNAL USE ONLY 23PMD, Martin Allgeier, Fall 2007

MP2 Measurement Options

Standard #B20ECG/RespSpO2 FASTNBP

Optional Temp/IBP #B22

Temp AND IBP

OR #B23CO2 ready MP2

INTERNAL USE ONLY 24PMD, Martin Allgeier, Fall 2007

X2 – MP2 Measurements Flexibility• Hemodynamic Extension• Capnography Extension

Extensions are NOT operable without power from monitor or power supplyM3012A

M3015A

M3014A

Page 13: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 13

INTERNAL USE ONLY 25PMD, Martin Allgeier, Fall 2007

X2 – MP2 Measurement Selection Window

• New look• Unavailable measurements grayed-out• Measurement conflicts displayed in red

INTERNAL USE ONLY 26PMD, Martin Allgeier, Fall 2007

X2 – MP2 Clinical applications - Options

X2 MP2

StandardST segment analysis

StandardEASI 12 leadStandard5-/6-lead ECG

#C15StandardFull NetworkingStandard (but without ECG Sync Cable #SN3)ECG Sync Pulse Output

#C13StandardST Map

#C01

#C12 (as a hardware option)Conventional 12 leadStandardFull Arrythmia

StandardBasic Arrythmia

Page 14: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 14

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

MP2 Hardware - Standard

• All MP2 monitors will come with –1 Handle–1 Anti-Slip Pad–1 Power and Network Adapter–1 SRL Cable–1 Battery with Charge Adapter–Network Hardware (need option C15 to

connect to PIIC)

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

X2 Hardware - Standard

• All MP2 monitors will come with –1 Anti-Slip Pad–1 SRL Cable (you need to order Option

SC? For length)–1 Battery with Charge Adapter–Network Hardware & Software

Page 15: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 15

INTERNAL USE ONLY 29PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware - Options

X2 MP2Standard#E31Carrying handle

#E18Extra 5 Anti-slip pad

INTERNAL USE ONLY 30PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware - Options

X2 MP2

Part No. 9898 031 53021 ordirectly from GCX

Roller stand (no optionnumber)

#E20MMS mounting clamp

Page 16: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 16

INTERNAL USE ONLY 31PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware – Future Options

X2 MP2

#E23Protective casing

INTERNAL USE ONLY 32PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware – Future Options

X2 MP2

#E19Carrying Strap

Page 17: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 17

INTERNAL USE ONLY 33PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware - Options

X2 MP2

#J47 (ROW)Instrument telemetry 2.4 GHz

Locatiaon tracking via PIIC

Standard#E27Power and network adapter

1 battery #E24 / 2 batteries #26Additional Lithium ion battery

#J45 (US only)Instrument telemetry 1.4 GHz

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

X2 – MP2 Hardware - Reminder

• For X2, battery can be charged by the Host Monitor. Only order Power & Network Adapter if needed to be monitoring outside the Host for extended time (eg X-Ray room)

• Order M8023A If you need extra Power and Network Adapters

• One Battery is included! All batteries will come with Adapter for the Battery Conditioner.

Page 18: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 18

INTERNAL USE ONLY 35PMD, Martin Allgeier, Fall 2007

ECG Sync Output

ECG Sync Output

INTERNAL USE ONLY 36PMD, Martin Allgeier, Fall 2007

X2 – MP2 ECG Sync Pulse OUT

• Connection to synchronize external medical devices– Defibrillator– CT/MR scanner– Trans esophageal echo– Intra-aortic balloon pump (IABP)…

• Digital output – no analog ECG waveform• Special cable required - M3002-61601• Automatic cable detection

Page 19: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 19

INTERNAL USE ONLY 37PMD, Martin Allgeier, Fall 2007

X2 – MP2 ECG Sync Pulse OUT

• Sync Pulse specification– Delay from R-wave peak to start of pulse 20 ms maximum

(per AAMI EC13)– Output signal > 2.4 V– Minimum required R-wave amplitude 0.5 mV

Sync Pulse marker

INTERNAL USE ONLY 38PMD, Martin Allgeier, Fall 2007

X2 – MP2 ECG Sync Pulse OUT

• SyncPulse Marker– Choices: On / Off– Default: On– Set to On and plug in the ECG Sync Pulse cable

SyncPulse markers in the ECG wave on the monitor screen

Main Setup > Measurements > ECG

+ =

Measurement Settings

Page 20: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 20

INTERNAL USE ONLY 39PMD, Martin Allgeier, Fall 2007

digital output

X2 – MP2 ECG Sync Pulse OUT

• ECGOut Size Up/Down– Changes the level of the output signal

for analog output (ECG waveform)– when X2 in companion mode with a

host monitor

Main Setup > Measurements > ECG

analog output

> 2.4 V

INTERNAL USE ONLY 40PMD, Martin Allgeier, Fall 2007

BatteryBattery

Page 21: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 21

INTERNAL USE ONLY 41PMD, Martin Allgeier, Fall 2007

X2 – MP2 Battery• Battery must always be in X2/MP2, even

when running on AC power• Changing the battery with AC power has

no influence on monitoring– After 15 seconds, severe yellow alarm

– Changing the battery without AC power switches off monitor

– Normal monitor resuming afterwards• Battery minimum 3 hours operating time

INTERNAL USE ONLY 42PMD, Martin Allgeier, Fall 2007

X2 – MP2 Battery LED

Battery recharges automatically when the X2/MP2 is connected to a host monitor or external power supply

Battery or charger malfunctionBattery or charger malfunction

Red flashing intermittently

n/a

Battery charging(off when fully charged)

Connected to monitoror external power supply

Less then 10 minutes power remainingRed flashing

n/aYellow

Running on batteryBattery LED colors

Page 22: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 22

INTERNAL USE ONLY 43PMD, Martin Allgeier, Fall 2007

X2 – MP2 Battery Charger and Conditioner

• Compatible with Philips Battery Charger and Conditioner M8043A used for batteries of M3/4 MP20/30/40/50

• Adaptor required (included with every battery ordered)

INTERNAL USE ONLY 44PMD, Martin Allgeier, Fall 2007

TrendsTrends

Page 23: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 23

INTERNAL USE ONLY PMD, Martin Allgeier, Fall 2007

X2 – MP2 Trends

• Both X2 and MP2 can store up to– 48 Hrs @ 5 minute– 24 Hrs @ 1 minute– 4 Hrs @ 12 seconds

• All 3 are being stored in both monitors simultaneously.

• For X2, only 8 Hr of data are uploaded to Receiving Monitor.

Supplies for MMS+

Dave Danehy, Sr. Product ManagerElectrodes, Paper, Fetal, Cardiac Output & AccessoriesMonitoring Supplies2007

Page 24: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 24

Dave Danehy, August 200747

What about Supplies…? Things to remember!

• Comprehensive portfolio for your customer’s needs– Reusable & Disposable Supplies

• Tools – New Product Reference Table– Literature

Dave Danehy, August 200748

Product Reference Table

Coming so

on!

Page 25: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 25

Dave Danehy, August 200749

Features and Benefits of MMS+ Supplies

•2 m drop protection provides durability in harsh environments•Meets IEC 60721-3-7/IEC TR 60721-4-7 requirements for vibration, shock and free fall.

Protective Case, 989803153871

• Pad design provides anti slip surface for MMS+ on tables and other flat surfaces.• Pack of 5

Anti Slip Pad, 989803157171

• Durable strap allows for better patient mobility• Integrated cable organizer for better cable management

Carrying Strap, 989803153441

· Provides 3 hrs basic monitoring time for convenient patient transport

Lithium Ion Battery, M4607A

Dave Danehy, August 200750

Tools to help!

• Reference Guide• On Line Store• 800 Number (US only)• Local Supplies Sales Rep• Brochure

– 4522 962 17611/864

Page 26: All you need to know about MP2 4sept07 - Philips

NPI Sept 2007 Please contact your local marketing center for latest information

Confidential. For internal use only 26

Dave Danehy, August 200751

Why should you quote?

• Creating a full Philips customer!– Hardware & supplies– Bigger footprint in your account– Creates a loyal customer

• We’re only a phone call away for information and support!