Top Banner
All Wall” All Wall” as a as a Superstruct Superstruct ure ure Walls on a footer Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate Methods of Construction class.
22

“All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Dec 24, 2015

Download

Documents

Phebe Fisher
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

““All Wall” All Wall” as a as a

SuperstructSuperstructureureWalls on a footerWalls on a footer

Presentation to the Architectural and Construction Students at the University of Florida

in their Alternate Methods of Construction class.

Page 2: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Superstructure on Superstructure on FootersFooters

The 2The 2ndnd and and 33rdrd floor in floor in this picture this picture is the is the habitable habitable space.space.

The 1The 1stst floor floor is a footer/ is a footer/ basement.basement.

Page 3: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Cross Section for Design Cross Section for Design PlansPlans

Page 4: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Considerations for a Considerations for a BuildingBuilding

Hurricane Resistance

Energy Efficient

Mold Resistance

Fire Resistance

Termite/Bug Resistance

Ease of Manufacturing the walls

Ease of Installation

Easy for Building Departments to Inspect

Easy for local Engineers and Architects to use for design

Cost to Construct

Cost to live in the home. Monthly Outlay

Page 5: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Considerations for a Considerations for a BuildingBuilding

Hurricane Resistance

Energy Efficient

Mold Resistance

Fire Resistance

Termite/Bug Resistance

Ease of Manufacturing

Ease of Installation

Easy for Building Departments to Inspect

Easy for local Engineers and Architects to use for design

Cost to Construct

Cost to live in the home. Monthly Outlay

Ask a B

uilder

Developer

(Only to meet codes.)

(Only to meet codes.)

Easy to fin

d “3 Bids”

Doesn’t care - Everybody else is bldg this way, so it must be OK

Doesn’t have to get involved. Easy is the operative word here.

Absolutely – ‘Does Not Care’, they are only worried about their ability to get the house up and on to the next one. If Governing agency allows it, they will build it. No Conscience – No Accountability. Two major traits of a Serial Killer.

Ask a Builder or Developer

Page 6: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Considerations for a Considerations for a BuildingBuilding

Hurricane Resistance

Energy Efficient

Mold Resistance

Fire Resistance

Termite/Bug Resistance

Ease of Manufacturing

Ease of Installation

Easy for Building Departments to Inspect

Easy for local Engineers and Architects to use for design

Cost to Construct

Cost to live in the home. Monthly Outlay

Ask th

e Home O

wner

Ask a Future Home Owner

Page 7: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Considerations for a Considerations for a BuildingBuilding

Hurricane Resistance

Energy Efficient

Mold Resistance

Fire Resistance

Termite/Bug Resistance

Ease of Manufacturing

Ease of Installation

Easy for Building Departments to Inspect

Easy for local Engineers and Architects to use for design

Cost to Construct

Cost to live in the home. (Monthly Outlay)

Ask th

e NEW

Product

Manufacturer /

Installe

rFor Sales Purposes

For the ability to be competitive to bring in a new product

LOW COST TO CONSTRUCT IS THE ONLY THING THAT IS BRINGING ALL WALL TO THE MARKET. (Sad, but TRUE)THE LESS MONTHLY COSTS IS WHAT WILL SUSTAIN ALL WALL IN THE MARKET.

Ask the NEW Product Manufacturer

Page 8: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

What is it going to take to get the Builder to consider the BENEFITS of building a stronger, healthier, and safer home that costs more to build and

costs LESS to live in and then use this information to enhance his BID presentation to help secure the job?

Get the IRS involved new federal tax credits for residential energy efficiency Energy Efficient Homes

Under the provision for energy efficient homes, an eligible contractor who constructs a qualified new energy efficient home may qualify for a credit of up to $2,000. The credit is available for all new homes, including manufactured homes constructed in accordance with the Federal Manufactured Homes Construction and Safety Standards.The home qualifies for the credit if:

•It is located in the United States; •Its construction is substantially completed after August 8, 2005; •It meets the statutory energy saving requirements, and •It is acquired from the eligible contractor after December 31, 2005, and before January 1, 2009, for use as a residence.

In general, to meet the energy saving requirements, a home must be certified to provide a level of heating and cooling energy consumption that is at least 30 to 50 percent in the case of manufactured homes, and 50 percent for other homes below that of a comparable home constructed in accordance with the standards of the 2004 Supplement to the 2003 International Energy Conservation Code. It must also have building envelope component improvements providing a level of heating and cooling energy consumption that is at least 10 percent below that of a comparable home.

The All Wall System performs up to 75% better than code built homes.

Page 9: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

They prepared the following report:

Two Gainesville, FL builder case studies are presented that detail the critical elements of a systems engineering process that has resulted in increased sales and fewer callbacks for several builders. Additional benefits these builders realized include:

•enhanced customer satisfaction through improved comfort, •improved indoor air quality and •lower operating costs.

Each of these builders chose to improve the performance and marketability of their homes.

Get local government funded organizations involved and local energy consultants involved by providing Case Studies:

•Florida Solar Energy Center•Ken Fonorrow, www.FloridaHERO.com

Page 10: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

0

2

4

6

8

10

12

14

16

18

20

R-5 R-10 R-15 R-20 R-25

6" Wood

Concrete Blocks

ICF-ICI

All Wall-CICEne

rgy

Sav

ings

%

Page 11: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Explanation of Chart:

Why has ‘All Wall’ and ICF methods of construction proven superior to the standard methods of construction?

1. Sealed Envelope because of continuous poured concrete.

2. The concept of keeping the temperature that is outside outside and controlling the temperature inside. The FOAM makes this happen.

3. The air conditioning ducts have zero leakage to the outside air and they are in air that is only about 7 deg higher than the house is maintained.

Notice that the R-Value (a myth) is not mentioned here because of it’s minimum level of significance.

R-Value is a marketing tools for hollow wall construction, does not apply to mass walls, to any beneficial degree, and very Misleading to the PUBLIC.

On an All Wall Eco-Home we foam under the plywood of the roof. MAJOR BENEFIT!

Page 12: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Why is the ‘All Wall System’ method of construction superior to

it’s closest competitor?

Page 13: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

More usable interior space. 

5,000 SF home yields greater than 95 SF MORE Interior Area

Page 14: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Non-Combustible and Non-Flammable exterior load bearing walls. 

ICF’s, Wood Framing, and Concrete Blocks use drywall boards on the interior.

Page 15: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

More MOLD resistant because the concrete board is the most mold resistant material to use, as is

concrete. 

ICF’s, Wood Framing, and Concrete Blocks use drywall boards which suck up and hold water for mold to grow.

Page 16: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

More pest and termite resistant: 

ICF’s use drywall boards and foam exposed – pests can burrow a nice home.Wood and Concrete Blocks use wood, insulation and drywall that pests can burrow a nice home.

Page 17: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Easier to have plans drawn and approved.The concrete exceeds all ACI codes and

the light gage steel exceeds all LGSEA codes.  

All Wall is code compliant for any home and incorporates columns and stand alone beams. All of which exceed the strength of any other method of

construction including concrete lintels, which are typical of block construction.

Page 18: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Easier to install.

1. Entry Level Employees2. Less costly bracing 3. Faster to erect and fill, less labor costs 4. Faster removal of any forming, such as corners,

and clean up

Page 19: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Zero Site waste

Page 20: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

Better resistance to street noise. 

The harder exterior bounces sounds off, then foam absorbs.

Page 21: “All Wall” as a Superstructure Walls on a footer Presentation to the Architectural and Construction Students at the University of Florida in their Alternate.

More Energy Savings with All Wallhttp://www.ornl.gov/roofs+walls/research/detailed_papers/thermal/index.html