B N L M D C H A G J I A F E Standard Lighting Column Article number (Buried) ABB.001.040 ABB.002.050 ABB.003.050 ABB.004.050 ABB.005.050 ABB.006.060 Article number (Flanged) AFB.001.040 AFB.002.050 AFB.003.050 AFB.004.050 AFB.005.050 AFB.006.060 Surface area of column / m² 1.74 2.05 2.05 2.12 2.12 2.51 Dimensions A Base 114 114 114 122 122 122 B Top 60 60 60 60 60 60 C Mass 12.5 14.5 14.4 17.5 17.3 20.5 D Wall thickness 2.5 2.5 2.5 3 3 3 E Light point height 4000 5000 5000 5000 5000 6000 F Groundrooth protection 800 800 800 800 800 1000 G Access door position 420 420 420 420 420 420 H Access door dimensions 400x85 400x85 400x85 400x85 400x85 400x85 I Cable entry dimensions 150x50 150x50 150x50 150x50 150x50 150x50 J Cable entry position 500 500 500 500 500 500 K Max. dimensions of cutout 80x60x300 80x60x300 80x60x300 80x65x300 80x65x300 80x65x300 L Bracket Lenght 750 750 750 750 750 750 M Radius 300 300 300 300 300 300 N Angle 5° 5° 15° 5° 15° 5° Column with baseplate Baseplate Article Number 600 600 600 601 601 601 Surface area of column 1.49 1.80 1.80 1.86 1.86 2.19 Ac Value in M 2 Mass / kg 10 8 8 10 10 5 136 km / hour 0.09 0.05 0.05 0.11 0.11 0.06 161 km / hour 0.05 0.02 0.02 0.06 0.06 0.02 184 km / hour 0.03 - - 0.03 0.03 - 204 km / hour 0.01 - - 0.01 0.01 - Lighting Point Height 4000 5000 5000 5000 5000 6000 Conical Poles With Consoles CONICAL POLES WITH CONSOLES Technical Data
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
K Max. dimensions of cutout 110x145x485 110x145x485
L Bracket Lenght 1250 1250
M Radius 380 380
N Angle 15° 15°
Column with baseplate
Baseplate Article Number 607 607
Surface area of column 3.91 3.91
Ac Value in M2
Mass / kg 12 12
136 km / hour 0.19 0.19
161 km / hour 0.16 0.16
184 km / hour 0.07 0.07
204 km / hour 0.02 0.02
Lighting Point Height 12000 14000
CONICAL POLES WITH CONSOLESTechnical Data
39
Standard Lighting Column
The standard lighting column has a base-holder, thermoplastic protection and integrated mounting rail, without options or other accessories.
Dimensions
The specifications of the standard lighting column are expressed in the following units:A Base diameter - mmB Top diameter - mmC Mass - kgD Wall thickness - mmE Lighting point height - mmF Groundrooth protection - mmG Access door position - mmH Access door dimensions - mm - (height x width)
I Cable entry dimensions - mm - (height x width)
J Cable entry position - mmK Max. cutout dimensions - mm - (height x depth x width)
Surface area of lighting column …m2
Lighting Column With Baseplate
Standard lighting column with mounted baseplate (excluding base-holder length), without options or accessories.
Ac Value in m2
The Ac value is a combination of the projected surface area and the luminare fixing depth’s coef-ficient of from, expressed in m2 . The maximum Ac values permitted have been stated for the various wind speeds. The values indicated have been de-termined using the European EN-40 standard. The mass of the light fitting on which the calculations have been based is also stated.