A.GIBSON P.NIEHOFF A.SANDRA 4 : 32 : 33 PM 23 / 07 / 14 c:\users\pgoley\wpc\dms19925\ALB_G1201.dgn Description Date In Serv Rev. Drawn By Designed By Checked By Approval Date Drawing Number In Serv. Scale Sheet Size Sheet No. Down Location Up Location Datum Approved Ind. Review Revision Franchisee / Lessee Consultant East. North. ID# East. North. ID# Approv. Ind. Rev. Checked File Name Revised By Designed Victrack’s prior written consent. not be provided to, or used by, any other person without person or organisation to whom Victrack provides it. It may This drawing is provided only for the information of the dimensions. All written dimensions take precedence over scaled drawing or the information contained in it. liability in relation to the use of, or any reliance on, this Victrack from all and any loss, damage, cost, expense or contained in this drawing. Each user of this drawing releases the completeness, accuracy or quality of any information responsibility for, and makes no representations in relation to, maximum extent permissible by law, Victrack takes no information provided by, persons other than Victrack. To the This drawing has been prepared by, or compiled from of Ce r ti f i e d By : ( BL OCK LETTERS) ( SGNAT URE) ( DATE) Project Drawing Number 01 01 MGA Z55 G.DODS P.GOLEY ALB_G1201.dgn ALB_G1201 INDEX LOCATION: ALB522MB SIGNALS ALBION 308085.860 31/01/14 5817191.147 A3 N.T.S. WPC-DRG-TBB-GSG-0-24-ALB-1201 03/06/14 Plan No. Rev Title Plan No. Title Rev ALBION INDEX - ALB522MB DETAILS OF SIGNAL MODULE NOS. 12S51 & 12S54 DATA LINK MODULE CONNECTIONS A & B EARTHING DETAILS INDEX INTERFACE CIRCUITS WITH M540GR & ALB443GR ALB_G1205 ALB_G1202 ALB_G1210 ALB_G1207 ALB_G1208 ALB_G1211 ALB_G1201 ALB_G1204 ALB_G1206 ALB_G1212 ALB_G1209 ALB_G1203 POWER SUPPLY (AC & DC) & BOX LIGHTS ALBION INTERFACE CIRCUITS & POWER ALARM INDICATIONS - MODULE 12S57 CSEE TRACK FEED NOS. M540 & M541, CSEE TRACK RELAY NO. 522 INTERFACE CIRCUITS AND TPWS CONTROL NO. ALB522 - MODULE 12S54 LAYOUT OF APPARATUS, TERMINATIONS & CONTACT NOS. IN ALB522MB (7 SHEETS) SIGNAL CONTROL & MECHANISM NO. ALB522 - MODULE 12S51 DETAILS OF SIGNAL MODULE NO. 12S57 REFERENCES ALB_G7064 ALB_G7014 ALB_G7047 SUN_G7025 COMMUNICATIONS DATA LINK ARCHITECTURE ALBION CABLE RUNNING PLAN 13.400KM - 15.500KM INCL. VLINE/ARTC LINES (13300M - 14024M) TRACK CIRCUITS, BONDING & SIGNALLING APPARATUS (13300M - 14400M) ALBION SIGNALLING ARRANGEMENT 13.340KM - 15.500KM
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:3
3 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1201.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1201.dgn
ALB_G1201
INDEX
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1201
03/06/14
Plan No. Rev Title Plan No. TitleRev
ALBIONINDEX - ALB522MB
DETAILS OF SIGNAL MODULE NOS. 12S51 & 12S54
DATA LINK MODULE CONNECTIONS A & B
EARTHING DETAILS
INDEX
INTERFACE CIRCUITS WITH M540GR & ALB443GR
ALB_G1205
ALB_G1202
ALB_G1210
ALB_G1207
ALB_G1208
ALB_G1211
ALB_G1201
ALB_G1204
ALB_G1206
ALB_G1212
ALB_G1209
ALB_G1203
POWER SUPPLY (AC & DC) & BOX LIGHTS
ALBION INTERFACE CIRCUITS & POWER ALARM INDICATIONS - MODULE 12S57
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1202.dgn
ALB_G1202
CSEE TRACK RELAY NO. 522
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1202
CSEE TRACK FEED NOS. M540 & M541,
03/06/14
V3
#2#1
#2
#2#1
#2
3
4
5
6 7
8
1
2
TO TRACK
TRACKS
TO TRACK TERMINATION
TO EQUIPMENT
TERMINAL 2
TERMINAL 4
TO TRACK ARRESTOR
TO EQUIPMENT
TO TRACK TERMINATION
TYPE SANKOSHA 3Y20-290GT
TYPICAL TERMINAL ARRESTOR WIRING ARRANGEMENT FOR M540TX, M541TX & 522RX
EARTH WIRE 7/0.85mm G/Y
SCREEN FOR TRACK CABLE
1-2, 3-4, 5-6 & 7-8 ARE INTERNALLY BRIDGED
#1
#2
REFER TO EARTHING PLAN DETAILS ALB_G1211
TO MAIN EARTH BAR VIA 7/0.85mm G/Y EARTH WIRE.
EARTHING VIA EK10 TERMINAL TO G-RAIL (ROW G), THEN FROM G-RAIL CONNECTED
#2: TRACK ARRESTOR TYPE - SANKOSHA 3Y20-290GT
#1: SCREEN IS SOLIDLY EARTHED TO EK10 ON ROW G BELOW TRACK TERMINALS.
HEAT SHRINK IS INSTALLED
: SCREEN INSULATED AND NOT TERMINATED IN TRACK SIDE UNIT.
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED
NOTES:
V1
V7
V2 V4 V5 V6
M1 M2M3 M4M5
M540TX
(TA1)
T1-1 T1-2
SCREEN
G5
E1
E2
1
4
V1 (INT)
V2 (INT)
V1 (EXT)
V2 (EXT)
M540TTMU
1B24
(ALB522MB)
1N24
1
1R
2
T1-3 T1-4
(ALB522MB)
G1
G2
95mm† FLEX ALUMINIUM AF
2000Hz
ALB_G1463 (M540GR)REFER TO PLANTO TRACK RELAY
A+
A-
SHIELDED
PT QUAD 0.90mm†
M540TB
M540TN T1-6
V3 V4 V5 V6
M1 M2M3 M4M5
M541TX
(TA2)
T2-1 T2-2
SCREEN
G16
E1
E2
1
4
V1 (INT)
V2 (INT)
V1 (EXT)
V2 (EXT)
M541TTMU
2B24
(ALB522MB)
2N24
1
1R
2
T2-3 T2-4
(ALB522MB)
G12
G13
95mm† FLEX ALUMINIUM AF
2300Hz
ALB_G1404 (ALB541MB)REFER TO PLANTO TRACK RELAY
V7
V8
A+
A-
SHIELDED
PT QUAD 0.90mm†
M541TB
M541TN T2-6
L+
L-
V1
V2 A- A+
C C2C1
SCREEN
SHIELDED
PT QUAD 0.90mm†
9
10
1
4
V1 (INT)
V2 (INT)
V1 (EXT)
V2 (EXT)
522RTMU
(ALB522MB)
G23
G24
(TA3)
T3-2
2
2
2L
(ALB522MB)
1N24
1B24
MT/8-8
522TR R1 R2
G27
522RX
2600Hz
95mm† FLEX ALUMINIUM AF
ALB_G1404 (ALB541MB)REFER TO PLANTO TRACK FEED
522RB
522RN
T3-1
T3-4 T3-3
T3-6
A.GIBSON P.NIEHOFF
A.SANDRA
SIGNAL CONTROL & MECHANISM
4:3
2:3
6 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1203.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1203.dgn
ALB_G1203
NO. ALB522 - MODULE 12S51
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1203
03/06/14
O/P5 77
O/P6 78
O/P7 60
RAS 40
(I/P7)C/P1 63
C/S1 79
E2
E6
c1
c2
c3
c4
c5
c6
E16
(VR)O/P4 76
C/P0 62
BXI 67
NXI 36
37
54
52
34
#1
E32
E28
E25
#1
#1
c8
c4
c5
c1
JAH
ALB522V 9 10
(VN)
I/P5
(VR)
I/P4
NXE 28
BXE 25
c1
c3
c4
c6
O/P1 72
O/P3 58
RAS 43
C/S2/3/4 74
45
27
(TR)
I/P1
(I/P6)C/P4 64
Pt. 10c 7/0.50mm
Pt. 10c 7/0.50mm
c2
c3
c7
7/0.85mm
Pt. 10c 7/0.50mm
21 A
522TR
D1
2
D2
2
D3
2
D4
2
D6
2
O/P2 75
1R
1L
R1
15 ohm
5W
R2
15 ohm
5W
SIGNAL MODULE 12S51
E31
E26
E27
NGE
HGE
DGE1 4
2 5
3 6
UGI TC2 TRI-COLOUR LED
aALB522G
NGE
HGE
DGE1 4
2 5
3 6
UGI TC2 TRI-COLOUR LED
bALB522G(ALB522MB)
E11
73O/P0RD
MNHXC1 2H/4-4
ALB522VR R1 R2
(ALB522MB)
E21
(ALB522MB)
E22
D7
2
D8
2
#1
#1
(ALB522MB)
E30
(ALB522MB)
E29
UBX
(ALB522MB)
UNX
8
3R
6
C1
C2
C3
C4
C5
C6
C7
C8
E24
(ALB522MB)
E23
ALB522VR
ALB522VR
(ALB522MB)
E1
2 1
ALB522V
c6
6 5
ALB522V
12S51NXI
E3
E5
(ALB522MB)
E4
E13
(ALB522MB)
E14
2c 7/0.85mm
21 A
ALB522VR
21 D
ALB522VR
78 A
ALB522VR
78 D
ALB522VR
MPU7(1)
I1 E1
I2 E2
I3 E3
I4 E4
I6 E6
I7 E7
I5 E5
I8 E8
I1
I2
E1
E2
MPU4(2)
I1
I2
E1
E2
MPU5(3)
I1
I2
E1
E2
MPU5(4)
I1
I2
E1
E2
MPU5(5)
8 7
ALB522V
4 3
ALB522V
VIA G/Y 7/0.85mm WIRE. REFER TO EARTHING DETAILS PLAN No. ALB_G1211.
#1: MPU EARTHED TO G-RAIL (ROW EE), THEN FROM G-RAIL CONNECTED TO MAIN EARTH BAR
HEAVY DUTY CONTACT (C1,C2), (C3,C4), (C5,C6), (C7,C8) ARE INTERNALLY LINKED FOR MNHXC1 2H 4-4 RELAY
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED (BLUE WIRE TO TFM PLUG COUPLER)
NOTES:
TYPICAL
RESISTOR WIRING
15 ohm 15W
B
C
T
1
2
3
4
5
6
D/H/NGE
MODULE
LED SIGNAL
TRI-COLOUR
TERMINAL BLOCK IN SIGNAL MECHANISM
TYPICAL UNITED TC2 TRI-COLOUR
SIGNAL HEAD WIRING
PO
WE
R M
OD
ULE
TRI-
CO
LO
UR L
ED SIG
NA
L
BLK
RD
BLK
cSUN532G
HGE1 2
IRPL U2L SYTLE 90 DOT
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:3
7 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1204.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
HEAVY DUTY CONTACT (C1,C2), (C3,C4), (C5,C6), (C7,C8) ARE INTERNALLY LINKED FOR MNHXC1 2H 4-4 RELAY
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED (BLUE WIRE TO TFM PLUG COUPLER)
NOTES:
#2
21 A
ALB522(TSS)VR 78 A
ALB522(TSS)VCR
R4 ALB522TSS VGO
3.9K ohm
25W
65 A
ALB522(TSS)VR
65 D
ALB522(TSS)VR
MNHX 8-4
ALB522(TSS)VRR1 R2
(TPS)
I/P1
B50
(ALB522MB)
N50
1
1R
2
UBX
(ALB522MB)
UNX
11
5R
2
UBX
(ALB522MB)
UNX
10
5L
2 (DIS BOX)
1
3
6
R2 R1 ALB522(TSS)VCR
MBA/8-8
1
TSS PROVING (IN)
TSS PROVING (OUT)8
7
SUPP I/P - NX
SUPP I/P - BX
MAIN I/P - NX
MAIN I/P - BX
6
5
4
3
2 POWER IN - NX
POWER IN - BX
TSS
9
10
12
13
14
EARTH
ALB522 SIGNAL TSS
0.25
SIM - RED MODULE PART No. 604366-20
G/Y 32/0.20mm
f3(ND)
LOOP
ARMING
f2(ND)
LOOP
TRIGGER
TSM - GREEN MODULE PART No. 604367-21
11
5
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:3
9 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1205.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1205.dgn
ALB_G1205
ALBION INTERFACE CIRCUITS AND
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1205
POWER ALARM INDICATION - MODULE 12S57
03/06/14
37
54
52
34
BXI
NXI
67
36 1L
1R
2L
24
42
45
27
32
50
47
29
5L
(M526UPS)
Pt. 10c 7/0.50mm
(M526UPS)
12S57NXE
F6
12S57BXE
POK)
(UPSCOC
I/P0
(UPS)ALMK
I/P1
#1
#1
#1
#1
(ALB522MB)
F8
5R
3R
2L 1R
3L
2R
4L
4R
2L
2R
3L
(ALB522MB)
F7
F4
F2
F5
F3
F1
REFER TO ALB_G1263
BXE 25
NXE 28 1L
1L
21 A
440TSP
21 C
ALB443PCP
MPU6(6)
I1 E1
E2I2
MNX
MPU6(7)
I1 E1
E2I2
MNX
MPU6(8)
I1 E1
E2I2
MNX
MPU6(9)
I1 E1
E2I2
MNX
(110ELDK)
I/P3
(HT)POK
I/P2
I/P 5
(TSP)
I/P 4
(PCP)
SIGNAL MODULE 12S57
12S57NXI
REFER TO ALB_G1260
#3
#5
#2
#5: M526F(UPSCOC)POR
#4: M526F(UPS)ALMK
#3: M526F(HT)POR
#2: M526F-BX & UPS ELD
VIA G/Y 7/0.85mm WIRE. REFER TO EARTHING DETAILS PLAN No. ALB_G1211.
#1: MPU EARTHED TO G-RAIL (ROW FF), THEN FROM G-RAIL CONNECTED TO MAIN EARTH BAR
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED (BLUE WIRE TO TFM PLUG COUPLER)
NOTES:
#4
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:4
1 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1206.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1206.dgn
ALB_G1206
M540GR & ALB443GR
INTERFACE CIRCUITS WITH
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1206
03/06/14
H2
H3
H4
H6
H5
B50
(ALB522MB)
N50
2
2L
2
B50
(ALB522MB)
N50
3
2R
2
B50
(ALB522MB)
N50
4
3L
2
(ALB522MB)
H1
(M540GR)
H7
H8
(ALB522MB)
H21
H22
(ALB443GR)
440TSPRF
1
2
3
4
(12B1999)
440TSPSRU
1
2
3
4
(5B1999)
ALB522AR
2MBA/4-4
ALB443PCPR2R4
(M540GR)
12 A
M540GR1
34 A
M540GR1
12 A
aM540HR1
34 A
aM540HR1
12 A
M540DR1
34 A
M540DR1
M540GR
aM540HR
M540DR
MBCA 2H/4-4
M540GR
MBA/8-8
aM540HR
MBA/8-8
M540DR
2MBA/4-4
ALB522ARR3 R1
DM578TR
DM578TR
CM578TR
CM578TR
440TSP
ALB443PCP
Pt. 20c 7/0.50mm
Pt. 20c 7/0.50mm
Pt. 20c 7/0.50mm
12 B
522TR
34 B
522TR
CM578NS
aM540HR
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED
NOTE:
DM578N
21 B
440TSP
78 D
ALB443PCP
43 B
440TSP
12 C
M540TPS
34 C
M540TPS
12 B
M540TPS
34 B
M540TPS
34 A
M540TPS
12 D
M540TPS
H14
H15
M540HR
M540HR
M540(TSS)VCR
M540HR
M540HR
H12
H13
M540TPS
MBA/12-4
M540TPSR2 R1
M578GR
21 A
M540TPS
DM578TR
DM578TR
CM578TR
CM578TR
CM578N
DM578N
CM578NS
(M540GR)
M540GR
M540HR
aM540HR
M540DR
M540(TSS)VCR (M540GR)
(M540GR)
Pt. 10c 7/0.50mm
12
M540V
M540TR
M540TR M540TPSRF
1
2
3
4
10VA
(1B2000)
6 5 A
M540GR16 5 A
M540DR16 5 A
aM540HR1
(M540GR)
NX
BX
H11
aM540HR
M540GR
UBX2
(ALB522MB)
UNX2
1
1R
2
MSRA/8-4
440TSP R2 R1
REFER TO PLAN ALB_G1470
REFER TO PLAN ALB_G1466
TO (ALB443GR)
CONTINUED ON PLAN ALB_G1477
REFER TO PLAN ALB_G1470
(M540GR)
440TSP/ALB443PCP
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:4
2 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1207.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1207.dgn
ALB_G1207
NOS. 12S51 & 12S54
DETAILS OF SIGNAL MODULE
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1207
03/06/14
O/P
7S 5
7
O/P
3S 5
5
RA
S 4
6
PS 5
6
RA
S 4
4
PS 4
8
E
#1
#1
1B
X
1N
X
32/0.2
0m
m B
LU
E
C/D
1 7
1
TE
RMIN
AL 1
5
1
11
10 8 1 2 3 4 5 7
"A"
5v "1"
0v "0"
MO
D
10 2 3 4 5
21
20
18
12
13
14
15
16
17
"B"
5v "1"
0v "0"
MO
D
10 2 3 4 5
26
O/P
7S 5
7
O/P
3S 5
5
RA
S 4
6
PS 5
6
RA
S 4
4
PS 4
8
53
80
BX 1
10
82
MO
DU
LE 1
2S54
#1
#1
C/D
1 7
1
C/D
2/3/4 7
0
TE
RMIN
AL 1
0
NX 1
10
2B
X
2N
X
32/0.2
0m
m B
LU
E
1
500
VA
500
VA
110
V/2
No. 110
V T
RA
NS
FO
RM
ER
110
0
110
0
110
0
12S51/5
4G
MF
1
R1L
1
R1L
C/S
1 7
9
C/S
2/3/4 7
4
GUID
E PIN
JA
CK S
CR
EW
GUID
E PIN
GUID
E S
OC
KE
T
12
3
45
7
810
11
12
13
14
15
16
17
18
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
62
63
64
65
66
67
70
71
72
73
74
75
76
77
78
79
80
82
GUID
E PIN
GUID
E PIN
JA
CK S
OC
KE
TG
UID
E S
OC
KE
T
(WIR
E SID
E)
FR
EE C
ON
NE
CT
OR A
NA
LY
SIS
DE
NO
TE
S C
RIM
PE
D PIN
DE
NO
TE
S W
IRE W
RA
P PIN
RO
TA
TIO
N C
OLL
AR)
(FIT
TE
D W
ITH A
NTI-
GUID
E PIN
JA
CK S
CR
EW
GUID
E PIN
GUID
E S
OC
KE
T
12
3
45
7
810
11
12
13
14
15
16
17
18
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
62
63
64
65
66
67
70
71
72
73
74
75
76
77
78
79
80
82
GUID
E PIN
GUID
E PIN
JA
CK S
OC
KE
TG
UID
E S
OC
KE
T
(WIR
E SID
E)
FR
EE C
ON
NE
CT
OR A
NA
LY
SIS
DE
NO
TE
S C
RIM
PE
D PIN
DE
NO
TE
S W
IRE W
RA
P PIN
RO
TA
TIO
N C
OLL
AR)
(FIT
TE
D W
ITH A
NTI-
1L
4
1L
4
10
1
1
R
(AL
B522
MB)
UN
X
UB
X
INT
ER
LO
CKIN
G
AD
DR
ES
S BIT
DE
CIM
AL/BIN
AR
Y
PR
OC
ES
SO
R A PIN N
o
PR
OC
ES
SO
R B PIN N
o
BIN
AR
Y A
DD
RE
SS
12S51
12
34
5(M
SB)
24
816
32
23
45
7
13
14
15
16
17
10
01
1 RR
OR
PS
I/L I
D N
o.
12
01100
0(L
SB)
0V
5V
MO
DIFIE
R
1 1 12 1
10
11
20
21
8 18 0 6
01
INP
UT
PIN
CU
RR
EN
T P
AT
HS
LA
MP P
RO
VIN
G
62 0
NO
NE
NO
NE
63 1
35
W7
64
65
66
23
4
35
W125
W2x60
WPIN
BX
NX
60
78
77
76
58
75
72
73
OU
TP
UT 0
OU
TP
UT 1
OU
TP
UT 2
OU
TP
UT 3
OU
TP
UT 4
OU
TP
UT 5
OU
TP
UT 6
OU
TP
UT 7
LA
BE
L
FIX
ED S
OU
RC
E
FIX
ED S
OU
RC
E
INP
UT C
ON
TA
CT S
EN
SIN
G S
OU
RC
E
PIN
INP
UT 0
INP
UT 1
INP
UT 2
INP
UT 3
INP
UT 4
INP
UT 5
INP
UT 6
CU
RR
EN
T P
RO
VIN
G
CU
RR
EN
T P
RO
VIN
G
37
52
32
47
27
42
24
45
29
50
34
54
RR
RR
FU
NC
TIO
N
aA
LB522
NG
E
aA
LB522
HG
E
aA
LB522
DG
E
AL
B522
V
bA
LB522
NG
E
bA
LB522
DG
E
aA
LB522E
C
bA
LB522E
C
AL
B522
VN
AL
B522
VR
522T
R
BXI
NXI
BX
EN
XE
67
36
25
28
ALL A
DD
RE
SS C
ON
NE
CTIO
NS W
IRE W
RA
PP
ED 1/0.5
mm I
NS
UL
AT
ED W
IRE (
BL
AC
K F
OR ’0’, R
ED F
OR ’1’)
INP
UT 7
RR
SIG
NA
L M
OD
ULE
43
SU
N3
RE
SE
T F
US
E 1
BX-1
cA
LB522
HG
E
40
INT
ER
LO
CKIN
G
AD
DR
ES
S BIT
DE
CIM
AL/BIN
AR
Y
PR
OC
ES
SO
R A PIN N
o
PR
OC
ES
SO
R B PIN N
o
BIN
AR
Y A
DD
RE
SS
12S54
12
34
5(M
SB)
24
816
32
23
45
7
13
14
15
16
17
11
01
1 RR
OR
PS
I/L I
D N
o.
12
01100
0(L
SB)
0V
5V
MO
DIFIE
R
1 1 12 0
10
11
20
21
8 18 0 6
01
INP
UT
PIN
CU
RR
EN
T P
AT
HS
LA
MP P
RO
VIN
G
62 0
NO
NE
NO
NE
63 1
35
W7
64
65
66
23
4
35
W125
W2x60
WPIN
BX
NX
60
78
77
76
58
75
72
73
OU
TP
UT 0
OU
TP
UT 1
OU
TP
UT 2
OU
TP
UT 3
OU
TP
UT 4
OU
TP
UT 5
OU
TP
UT 6
OU
TP
UT 7
LA
BE
L
FIX
ED S
OU
RC
E
FIX
ED S
OU
RC
E
INP
UT C
ON
TA
CT S
EN
SIN
G S
OU
RC
E
PIN
INP
UT 0
INP
UT 1
INP
UT 2
INP
UT 3
INP
UT 4
INP
UT 5
INP
UT 6
CU
RR
EN
T P
RO
VIN
G
CU
RR
EN
T P
RO
VIN
G
37
52
32
47
27
42
24
45
29
50
34
54
PS
RR
FU
NC
TIO
N
M540
GR
1
M540
DR
1
aM
540
HR
1
AL
B522(T
SS)V
R
AL
B522TP
WS (
TS
S) (R)
AL
B522TP
WS (
TS
S) (N)
AL
B522
AR
M540TP
BXI
NXI
BX
EN
XE
67
36
25
28
ALL A
DD
RE
SS C
ON
NE
CTIO
NS W
IRE W
RA
PP
ED 1/0.5
mm I
NS
UL
AT
ED W
IRE (
BL
AC
K F
OR ’0’, R
ED F
OR ’1’)
INP
UT 7
RR
SIG
NA
L M
OD
ULE
43
SU
N3
RE
SE
T F
US
E 2
BX-1
AL
B522 T
SS(D
UM)
40
TE
RMIN
AL 7
TE
RMIN
AL 8
TE
RMIN
AL 9
11
10 8 1 2 3 4 5 7
"A"
5v "1"
0v "0"
MO
D
10 2 3 4 5
21
20
18
12
13
14
15
16
17
"B"
5v "1"
0v "0"
MO
D
10 2 3 4 5
26
53
80
BX 1
10
82
NX 1
10
MO
DU
LE 1
2S51
70
C/D
2/3/4
PL
AN N
o.
AL
B_
G1211
RE
FE
R T
O E
AR
THIN
G D
ET
AIL
S
7/0.8
5m
m G/Y E
AR
TH W
IRE
(BL
UE W
IRE T
O T
FM P
LU
G C
OU
PLE
R)
ALL I
NT
ER
NA
L W
IRIN
G IS 2
4/0.2
0m
m U
NLE
SS O
TH
ER
WIS
E S
PE
CIFIE
D
R
EF
ER T
O E
AR
THIN
G D
ET
AIL
S P
LA
N N
o.
AL
B_
G1211
#1. 32/0.2
0m
m G/Y E
AR
TH W
IRE.
NO
TE:
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:4
4 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1208.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1208.dgn
ALB_G1208
NO. 12S57
DETAILS OF SIGNAL MODULE
LOCATION: ALB522MB
SIGNALS
ALBION
0.000308085.860
31/01/14
0.0005817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1208
03/06/14
E
#1
#1
3B
X
3N
X
32/0.2
0m
m B
LU
E
C/D
1 7
1
TE
RMIN
AL 1
6
TE
RMIN
AL 1
1
TE
RMIN
AL 1
2
1
500
VA
500
VA
110
V/2
No. 110
V T
RA
NS
FO
RM
ER
110
0
110
0
110
0
12S57
GM
F
1
R1L
C/S
1 7
9
10
2
2
L
(AL
B522
MB)
UN
X
UB
X
1L
4
GUID
E PIN
JA
CK S
CR
EW
GUID
E PIN
GUID
E S
OC
KE
T
12
3
45
7
810
11
12
13
14
15
16
17
18
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
62
63
64
65
66
67
70
71
72
73
74
75
76
77
78
79
80
82
GUID
E PIN
GUID
E PIN
JA
CK S
OC
KE
TG
UID
E S
OC
KE
T
(WIR
E SID
E)
FR
EE C
ON
NE
CT
OR A
NA
LY
SIS
DE
NO
TE
S C
RIM
PE
D PIN
DE
NO
TE
S W
IRE W
RA
P PIN
RO
TA
TIO
N C
OLL
AR)
(FIT
TE
D W
ITH A
NTI-
INT
ER
LO
CKIN
G
AD
DR
ES
S BIT
DE
CIM
AL/BIN
AR
Y
PR
OC
ES
SO
R A PIN N
o
PR
OC
ES
SO
R B PIN N
o
BIN
AR
Y A
DD
RE
SS
12S57
12
34
5(M
SB)
24
816
32
23
45
7
13
14
15
16
17
00
11
1 RR
OR
PS
I/L I
D N
o.
12
01100
0(L
SB)
0V
5V
MO
DIFIE
R
1 1 12 1
10
11
20
21
8 18 0 6
01
INP
UT
PIN
CU
RR
EN
T P
AT
HS
LA
MP P
RO
VIN
G
62 0
NO
NE
NO
NE
63 1
35
W7
64
65
66
23
4
35
W125
W2x60
WPIN
BX
NX
60
78
77
76
58
75
72
73
OU
TP
UT 0
OU
TP
UT 1
OU
TP
UT 2
OU
TP
UT 3
OU
TP
UT 4
OU
TP
UT 5
OU
TP
UT 6
OU
TP
UT 7
LA
BE
L
FIX
ED S
OU
RC
E
FIX
ED S
OU
RC
E
INP
UT C
ON
TA
CT S
EN
SIN
G S
OU
RC
E
PIN
INP
UT 0
INP
UT 1
INP
UT 2
INP
UT 3
INP
UT 4
INP
UT 5
INP
UT 6
CU
RR
EN
T P
RO
VIN
G
CU
RR
EN
T P
RO
VIN
G
37
52
32
47
27
42
24
45
29
50
34
54
PS
RR
FU
NC
TIO
N
440TS
P
AL
B443P
CP
M526F-1
10E
LD
K
M526F(H
T)P
OK
M526F(U
PS)A
LM
K
M526F(U
PS
CO
C)P
OK
BXI
NXI
BX
EN
XE
67
36
25
28
ALL A
DD
RE
SS C
ON
NE
CTIO
NS W
IRE W
RA
PP
ED 1/0.5
mm I
NS
UL
AT
ED W
IRE (
BL
AC
K F
OR ’0’, R
ED F
OR ’1’)
INP
UT 7
PS
SIG
NA
L M
OD
ULE
43
SU
N3
RE
SE
T F
US
E 3
BX-1
40
11
10 8 1 2 3 4 5 7
"A"
5v "1"
0v "0"
MO
D
10 2 3 4 5
21
20
18
12
13
14
15
16
17
"B"
5v "1"
0v "0"
MO
D
10 2 3 4 5
26
O/P
3S 5
5
O/P
7S 5
7
RA
S 4
4
PS 4
8
RA
S 4
6
PS 5
6
53
80
BX 1
10
82
C/D
2/3/4 7
0
C/S
2/3/4 7
4
NX 1
10
MO
DU
LE 1
2S57
PL
AN N
o.
AL
B_
G1211
RE
FE
R T
O E
AR
THIN
G D
ET
AIL
S
7/0.8
5m
m G/Y E
AR
TH W
IRE
(BL
UE W
IRE T
O T
FM P
LU
G C
OU
PLE
R)
ALL I
NT
ER
NA
L W
IRIN
G IS 2
4/0.2
0m
m U
NLE
SS O
TH
ER
WIS
E S
PE
CIFIE
D
R
EF
ER T
O E
AR
THIN
G D
ET
AIL
S P
LA
N N
o.
AL
B_
G1211
#1. 32/0.2
0m
m G/Y E
AR
TH W
IRE.
NO
TE:
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:4
6 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1209.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1209.dgn
ALB_G1209
BOX LIGHTS
POWER SUPPLY (AC & DC) &
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1209
03/06/14
#1
2 No. 110V 20W FLUORESCENT
BOX LIGHT
LOAD
LINE
UBX
(ALB522MB)
UNX
1L
1L
(ALB522MB)
B50
N50 1L
1L UBX
(ALB522MB)
UNX
4
3L
6 B50RF
1
2
3
50VA 4
(9B1999)
7/0.85mm
7/0.85mm
7/1.70mm
LS
(ALB522MB)
1B24
1N24 1L
1L
UBX
(ALB522MB)
UNX
7
4R
6
(ALB522MB)
2B24
2N24 1L
1L
UBX
(ALB522MB)
UNX
6
4L
6
UBX
(ALB522MB)
UNX
5
2R
2
UBX
UNX
7/0.85mm
#1
LOAD
LINE
UBX2
(ALB522MB)
UNX2
1L
1L
7/0.85mm
7/0.85mm
7/1.70mm
UBX2
UNX2SHEET 2
REFER TO PLAN ALB_G1260
M526UPS MTM S/B CB7
SHEET 2
REFER TO PLAN ALB_G1260
M526UPS MTM S/B CB12
E
E
2B24RF
T110
T0
B24
4.4A
(T6/2919)#1 TERMINAL 20
N24
(ALB522MB)
1
2
(ALB522MB)
1
2
L1
L2
L1
L2
TC(1)
(TC-150/802EI)
TRANSIENT PROTECTOR
EARTH
L1
L2
L1
L2
TC(2)
(TC-150/802EI)
TRANSIENT PROTECTOR
EARTH
#2 #2
NOTE:
ALL INTERNAL WIRING IS 24/0.20mm UNLESS OTHERWISE SPECIFIED
#1: FOR EARTHING DETAILS REFER TO PLAN No. ALB_G1211
#2: TERMINALS LOCATED ON AA ROW
LEFT
RIGHT
TERMINAL 1
1B24RF
T110
T0
B24
4.4A
(T6/2919)#1 TERMINAL 19
N24
TERMINAL 23
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:4
8 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1210.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
01 01
MGA Z55
G.DODS
P.GOLEY
ALB_G1211.dgn
ALB_G1211
EARTHING DETAILS
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1211
03/06/14
26
53
12S51
SIG
NA
L M
OD
ULE
26
53
C
C
FF
C
C
FF
MO
DU
LE A
DA
TA
LIN
K
MO
DU
LE B
DA
TA
LIN
K
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
EA
RT
H
EA
RT
H
G/Y 7/0.8
5m
m
G/Y 7/0.8
5m
m
(MP
U)
’EE’ R
OW
(MP
U)
’FF’ R
OW
G/Y 7/0.8
5m
m
G/Y 7/0.8
5m
m
EA
RT
H
G/Y 7/0.8
5m
m
53
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
26
(AL
B522
MB)
EA
RT
H
G/Y 7/0.8
5m
m
EA
RT
H
EA
RT
H
(OD
LIU P
OW
ER U
NIT)
12
V P
SU’A’
(OD
LIU P
OW
ER U
NIT)
12
V P
SU’B’
G/Y 3
2/0.2
0m
m
G/Y 3
2/0.2
0m
m
12S54
SIG
NA
L M
OD
ULE
12S57
SIG
NA
L M
OD
ULE
12S51/5
4 G
MF
12S57 G
MF
1B24
RF
BO
X F
RA
ME
G/Y 7/0.8
5m
m
2B24
RF
EA
RT
H
G/Y 7/0.8
5m
m
(TR
AC
K A
RR
ES
TO
R)
’G’ R
OW
G/Y 7/0.8
5m
m
(AL
B522
MB)
EA
RT
H
EA
RT
H
G/Y 7/0.8
5m
m
#1
#1
AL
B522 T
SS
(UB
X2/U
NX2 T
RA
NSIE
NT C
LA
MP)
TC(2)
(UB
X/U
NX T
RA
NSIE
NT C
LA
MP)
TC(1)
BP
AH
E24
24 W
AY E
AR
TH LIN
K B
LO
CK
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
(SPIK
E)
TO E
XT
ER
NA
L E
AR
TH
G/Y 7/1.7
0m
m
G/Y 7/1.7
0m
m
(AL
B522
MB)
MAIN E
AR
TH B
AR
SP
AR
E
SP
AR
E
G/Y 3
2/0.2
0m
m
RE
FE
R T
O S
TA
ND
AR
D D
RA
WIN
G S
TD
_G
0010
FO
R E
QUIP
ME
NT B
OX E
AR
THIN
G A
RR
AN
GE
ME
NT
#1. L
AB
ELLE
D "
DO N
OT DIS
CO
NN
EC
T"
NO
TE:
GR
OU
ND L
EV
EL
FF
EE
AA
SHEET 02 SHEET 03 SHEET 04
KEY PLAN
SHEET 05
SHEET 06 SHEET 07
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:5
1 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1212.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
02 07
MGA Z55
G.DODS
P.GOLEY
ALB_G1212.dgn
ALB_G1212
& CONTACT NOS.
LAYOUT OF APPARATUS, TERMINATIONS
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1212
03/06/14
2B
X - 2
FU
SE
RE
SE
T
B
MO
DU
LE
LIN
K
DA
TA
1B
X - 2
FU
SE
RE
SE
T
A
MO
DU
LE
LIN
K
DA
TA
1B
X - 1
FU
SE
RE
SE
T
12S51
MO
DU
LE
SIG
NA
L
2B
X - 1
FU
SE
RE
SE
T
12S54
MO
DU
LE
SIG
NA
L
3B
X - 1
FU
SE
RE
SE
T
12S57
MO
DU
LE
SIG
NA
L
OD
LIU ’B’
OD
LIU ’A’
GR
OU
ND L
EV
EL
FF
EE
AA
SID
E VIE
W
MP
U
MP
U
- I
NS
UL
AT
OR
BY I
NS
TA
LL
ATIO
N C
ON
TR
AC
TO
R
OFFS
ET DIS
TA
NC
E T
O B
E C
ON
FIR
ME
D
E*
I*
I* D
EN
OT
ES I
NT
ER
NA
L W
IRIN
G
E*
DE
NO
TE
S E
XT
ER
NA
L W
IRIN
G
AL
B522
MB R
EA
R VIE
W
MP
U7 (1)
7940006189
12
V P
SU ’A’
7940006189
12
V P
SU ’B’
OF I
NT
ER
NA
L & E
XT
ER
NA
L W
IRIN
G
SH
OWIN
G T
WO S
EP
AR
AT
E D
UC
TS
TO
P VIE
W O
F T
S32 (
G-R
AIL)
CO
LU
MN E
E & F
F
OFFS
ET
#4
#4
#3
#3
1
2
1
2
TC(2)
TC(1)
MP
U4 (2)
MP
U5 (3)
MP
U5 (4)
MP
U5 (5)
MP
U6 (9)
MP
U6 (8)
MP
U6 (7)
MP
U6 (6)
TO R
EA
R O
F E,
& F R
OW
S
TS32 R
AIL IS O
FFS
ET T
O E
NA
BLE A
CC
ES
ST
C1: T
RA
NSIE
NT C
LA
MP T
CA T
YP
E (
TC-1
50/8
02 EI)
- M
PU
7: S
LD
4-M
PU
7
- M
PU
6: S
LD
1-M
PU
6
- M
PU
5: S
LD
1-M
PU
5
- M
PU
4: S
LD
1-M
PU
4
ALL M
PUs T
YP
E N
OV
ARIS:
RE
FE
R T
O E
AR
THIN
G D
ET
AIL
S A
LB_
G1211
#4. 7/0.8
5m
m G/Y E
AR
TH W
IRE
#3. 1 N
o.
KS
K1
#2. 2 N
o. S
AK16
N U
BX/U
NX
#1. 2 N
o. S
AK16
N U
BX2/U
NX2
NO
TE
S:
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:5
5 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1212.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
03 07
MGA Z55
G.DODS
P.GOLEY
ALB_G1212.dgn
ALB_G1212
& CONTACT NOS.
LAYOUT OF APPARATUS, TERMINATIONS
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1212
03/06/14
#2
#1
1
WIR
EWIR
ES
HE
ET
SH
EE
T
A
UB
X
2 3 4 5 6 7 8
1 2 3 4 5 6 8
1
11 1
UB
X
WIR
EWIR
ES
HE
ET
SH
EE
T
B
UN
X
1N
X
1 2 3 4 5
1 2 3 4 5
UN
X
11 1
1
1 1
1
12S51/5
4G
MF
12S51/5
4G
MF
1
WIR
EWIR
ES
HE
ET
SH
EE
T
C
12S51
NXI
522T
R1
112S51
NXI
11
B50
B50
1 2 3
1 2 3
1
2B50
RF
1
1 1 1 1
2 24
4
11
12S57
BX
E
11
12S57
BX
E1
1
12S57
GM
F
B50
RF
BO
X LIG
HT
1B24
RF
2B24
RF
AL
B522
V2
7 11
1B24
1B24
M540T
X2
522
RX
2
M526F(U
PS
CO
C)P
OK
M526F(U
PS)A
LM
KM
526F(H
T)P
OK
2 3
11
2 3
12S57
NX
E
1 2 3 4 5 6
1 1
1 2 3 4 5 6
12S57
NX
E
M526F(U
PS
CO
C)P
OK
1 1
12S54 C/P
0
12S54 C/P
0R
31 2
1 1
1 2
1
12S57
NXI
12S57
NXI
SP
AR
E
1 2
1 2
1 1
1
AL
B522(T
SS)V
CR
22
aM
540
HR
1
9
12S57
GM
F
1B24
RF
2B24
RF
AL
B522 T
SS
AL
B522
V
1 2
1 2
1 1
1N
X
DL
MA
PS
U’A’
2N
X
1 2
1 1
2N
X
DL
MB
PS
U’B’
3N
X
13
NX
12S57 G
MF
1 2
1 1
11
9
11
N50
111
N50
aM
540
HR
1 1
12 3
2 3
1N
24
1 2S
PA
RE
1 1
11
N24
M540T
X
522
RX
1 2
2N
24
11
11
M541T
X2
N24
11
10
21
M526F(U
PS)A
LM
KM
526F(U
PS)A
LM
K
M526F(H
T)P
OK
M526F(H
T)P
OK
1 1
1 1
1 1
SP
AR
E
10
SP
AR
E
SP
AR
E
1B24
5 6
5 6
1B
X
1B
X12S51
2B
X
2B
X12S54
DL
MA
DL
MB
PS
U’B’
PS
U’A’
4 41 1 1 1
3B
X
3B
X12S57
4
M541T
X2
2B24
SP
AR
E
2B24
SP
AR
E
SP
AR
E
1 2 3 1 2 3
11 1 1 11 111
1
24
1 2 3 1 2 3
1 1 111
1
24
332
SP
AR
E
11
12
11
12
SP
AR
E
SP
AR
E
22 4
4S
PA
RE
66
SP
AR
E
SP
AR
ES
PA
RE
22
12S51
12S54
33
SP
AR
ES
PA
RE
SP
AR
ES
PA
RE
22
44
SP
AR
E
2S
PA
RE
SP
AR
E2
12S54
NXI
1 2 3 4
1 2 3 4
12S54
NXI
SP
AR
E
M540TP
SP
AR
E
1 1 1
1 1
SP
AR
E
AL
B522
AR
AL
B522TP
WS(T
SS)(
R)
AL
B522TP
WS(T
SS)(
N)
SP
AR
E
SP
AR
E
M526F(U
PS
CO
C)P
OK
M540
DR
1M
526F-1
10E
LD
K
M526F-1
10E
LD
KM
526F-1
10E
LD
K
M540
GR
AL
B522(T
SS)V
CR
SP
AR
ES
PA
RE
1
1a
M540
HR
1
440TS
P
AL
B443P
CP
M540
GR
M540
DR
AL
B522(T
SS)V
R
1
AL
B522 T
SS
AL
B522 T
SS
AL
B522 T
SS
1
13
13
SP
AR
E
SP
AR
E
1U
BX2
SP
AR
E
UB
X2
SP
AR
E
UN
X2
UN
X2
SP
AR
ES
PA
RE
11 2
1 2
M578
GR
11 2 3
1 2 3
1M
578
GR
SP
AR
E
SP
AR
E
1 1
G1209
G1209
G1209
G1209
G1207
G1207
G1208
G1207
G1208
G1209
G1209
G1209
G1209
G1203
G1204
G1204
G1204
G1206
G1206
G1206
G1202
G1202
G1202
G1207
G1210
G1210
G1207
G1210
G1210
G1208
G1203
G1204
G1204
G1204
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1204
G1204
G1205
G1205
G1209
G1203
G1204
G1204
G1205
G1205
G1205
G1205
G1205
G1205
G1204
G1204
G1205
G1206
G1209
G1208
G1209
G1209
G1204
G1209
G1206
G1206
G1209
G1202
G1209
G1207
G1210
G1207
G1210
G1208
G1209
G1207
G1203
G1209
G1204
G1204
G1206
G1202
G1202
G1207
G1210
G1207
G1210
G1208
G1206
610
10 6662
BO
X LIG
HT
2 2
2
G1209
SP
AR
E
SP
AR
E
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:5
6 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1212.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
04 07
MGA Z55
G.DODS
P.GOLEY
ALB_G1212.dgn
ALB_G1212
& CONTACT NOS.
LAYOUT OF APPARATUS, TERMINATIONS
LOCATION: ALB522MB
SIGNALS
ALBION
308085.860
31/01/14
5817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1212
03/06/14
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WIR
EWIR
ES
HE
ET
SH
EE
T
F
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WIR
EWIR
ES
HE
ET
SH
EE
T
D
O/P F
US
ES
MO
DU
LE
1 1 1 1 1
1 1 121
1 21 1 1 2
aA
LB522
DG
E
1 1
1 1 2 2
2 2 2 2 2
1
DL
M ’A’ B
US
DL
M ’B’ B
US
TE
ST P
OIN
T
DA
TA LIN
K
DL
MA
RX
DL
MA
RX
DL
MB
RX
DL
MB
RX
LIN
E I
N (P)
LIN
E I
N (P)
LIN
E I
N (
R)
LIN
E I
N (
R)
11 11
11 11
11
21
21
1
1
aA
LB522
NG
E
aA
LB522
HG
E
Na
AL
B522
DG
E
Na
AL
B522
HG
E
Na
AL
B522
NG
E
bA
LB522
DG
E
bA
LB522
NG
E
SP
AR
E
SP
AR
E
SP
AR
E
SP
AR
E
Nb
AL
B522
DG
E
Nb
AL
B522
NG
E
1 21 1
SP
AR
E
SP
AR
E
SP
AR
E
SP
AR
E
Nc
AL
B522
HG
E
cA
LB522
HG
E
AL
B522
NA
LB522
1 2 1 1 1 1 1
1 1 1 1 1 1 1
SP
AR
E
SP
AR
E
M526F(H
T)P
OK
111 1
M526F(U
PS
CO
C)P
OK
M526F(U
PS)A
LM
K
111
111
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
15
14
13
12
11
10987654321 16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
WIR
EWIR
ES
HE
ET
SH
EE
T
E
11
SP
AR
E
SP
AR
E
1 1 1
11 1 1
aA
LB522
DG
E
aA
LB522
NG
E
aA
LB522
HG
E
bA
LB522
DG
E
bA
LB522
NG
E2
cA
LB522
HG
E
AL
B522
VR
11
2
M540
GR
1
M540
DR
1
aM
540
HR
1
2 2 22
SP
AR
E
SP
AR
E
SP
AR
E
SP
AR
E
1 1 1 1 1 1
1 1
1 1
1 1
M526F-1
10E
LD
K
SP
AR
E
SP
AR
E
SP
AR
E
AL
B522
VN
AL
B522
VN
NA
LB522
VN
NA
LB522
VN
AL
B522
VR
AL
B522
VR
NA
LB522
VR
NA
LB522
VR
1 1
M526F-1
10E
LD
K
1 1
TE
RMIN
ATIO
NS
TE
RMIN
ATIO
NS
AL
B522 (
AR
MIN
G)
NA
LB522 (
AR
MIN
G)
AL
B522 (
TRIG
GE
R)
NA
LB522 (
TRIG
GE
R)
SC
RE
EN
SC
RE
EN
11
11
AL
B522(T
SS)V
R
M526F(H
T)P
OK
M526F(U
PS
CO
C)P
OK
M526F(U
PS)A
LM
K
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1204
G1204
G1204
G1204
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1204
G1204
G1204
G1204
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1210
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
G1205
1203
10c 7/0.50mm TO aALB522G
111111 11
1203
1203
1203
1203
1203
1111
1203
1203
1203
1203
10c 7/0.50mm TO bALB522G
#2
#1
1111 1111
10c 7/0.50mm TO M526UPS
10c 7/0.50mm TO ALB522V
11
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1203
G1204
G1204
G1204
G1204
G1204
G1204
G1204
G1204
G1204
G1204
G1204
G1204
#2 - 2
C 7/0.8
5m
m T
O A
LB522
V
#1 - 2
C 7/0.8
5m
m T
O c
AL
B522
G
NO
TE
S:
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
2:5
7 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1212.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from
of
Certifie
d B
y:
(BL
OC
K L
ET
TE
RS)
(SIG
NA
TU
RE)
(DA
TE)
Project Drawing Number
06 07
MGA Z55
G.DODS
P.GOLEY
ALB_G1212.dgn
ALB_G1212
& CONTACT NOS.
LAYOUT OF APPARATUS, TERMINATIONS
LOCATION: ALB522MB
SIGNALS
ALBION
0.000308085.860
31/01/14
0.0005817191.147 A3N.T.S.
WPC-DRG-TBB-GSG-0-24-ALB-1212
03/06/14
BACK CONTACTS ARE SHOWN UNDERLINED
TYPE
RELAYCOIL
1 SHT 2RELAY TITLE
3 SHT 4 5
A
SHT 6 7 SHT 8 1 SHT 2 3 SHT 4 5 SHT 6 7
B
SHT 8 1 SHT 2 3 SHT 4
C
5 SHT 6 7 SHT 8 1 SHT 2 3 SHT 4 5
D
SHT 6 7 SHT 8
522TR 8B
SHT
1 G1202
1 1
12S51 I/P1
G1203R3R1
8F
1 G1206 1
M540GR
1 G1206 1
M540GR
MT
R2
1
R4
ALB522(TSS)VCRMBA
8B
SHT
1 G1204
1 2
12S54 I/P3
G1204R3R1
1 G1204 1
12S54 I/P48F
R2
1
R4
ALB522(TSS)VR 4B
SHT
1 G1204
1 1
12S54 I/P4
G1204R3R1
1 G1204 2
ALB522(TSS)
1 G1204 2
ALB522(TSS)8F
MNHX R2
1
R4
aM540HR1 4B
SHT
1 G1204
1 1
aM540HR
G1206R3R1 1 G1206 1
aM540HR
1 G1206 1
M540TSP
8F
MNHX R2
2
R4
M540DR1 4B
SHT
1 G1204
1 1
M540DR
G1206R3R1 1 G1206 1
M540DR
1 G1206 1
M540TSP
8F
MNHX R2
2
R4
M540GR1 4B
SHT
1 G1204
1 1
M540GR
G1206R3R1 1 G1206 1
M540GR
1 G1206 1
M540TSP
8F
MNHX R2
1
R4
M540TPS MBA
4B
SHT
2 G1206
1 1
M540TPS
G1206R3R1 1 G1206 1
aM540HR
1 G1206 1
M578GR
1 G1206 1
M578GR
1 G1206 1
M540GR
1 G1206 1
M540GR
1 G1206 1
M540DR
1 G1206 2
12S54 I/P1
12F
R2
1
R4
SPARE SHT
R4R2
ALB522AR SHT
1 1G1206
1 2
12S54 I/P2
G1204
R3R1
2MBA
4F-4B
440TSP MSRA
4B
SHT
2 G1206
1 1
12S57 I/P
G1205R3R1
1 G1206 1
440TSP
1 G1206 1
ALB443PCP
8F
R2
2
R4
ALB443PCP SHT
G1206
R4R2
SPARE SHT
R3R1
1 2
12S57 I/P4
G1205
2 G1206 1
440TSP
2MBA
4F-4B
1 1
ALB522VR 4B
SHT
1 G1203
1 1
12S51 I/P4
G1203R3R1
1 G1203 1
12S51 I/P4
1 G1203 1
12S51 I/P5
1 G1203 1
12S51 I/P54F
1 1
ALB522V
G1203 1 G1203 1
ALB522V
1 G1203 1
ALB522V
1 G1203 1
ALB522V
MNHXC1 2H R2
2
R4
A.GIBSON P.NIEHOFF
A.SANDRA
4:3
3:0
0 P
M23/0
7/1
4
c:\users\pgoley\wpc\dms19925\ALB_G1212.dgn
DescriptionDateIn Serv Rev.
Drawn By Designed By
Checked By
Approval Date
Drawing NumberIn Serv.
Scale Sheet Size
Sheet No.
Down LocationUp Location Datum
Approved
Ind. Review
Revision
Franchisee / Lessee
Consultant
East.
North.
ID#
East.
North.
ID#
Approv.Ind. Rev.Checked
File Name
Revised By Designed
Victrack’s prior written consent.not be provided to, or used by, any other person withoutperson or organisation to whom Victrack provides it. It mayThis drawing is provided only for the information of the dimensions.All written dimensions take precedence over scaled drawing or the information contained in it.liability in relation to the use of, or any reliance on, thisVictrack from all and any loss, damage, cost, expense orcontained in this drawing. Each user of this drawing releasesthe completeness, accuracy or quality of any informationresponsibility for, and makes no representations in relation to,maximum extent permissible by law, Victrack takes noinformation provided by, persons other than Victrack. To theThis drawing has been prepared by, or compiled from