Member Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice. Distributed By :- Version : 16-09-2013 CERT NO.: 2001.1.0321 ISO 9001 : 2008 R DESCRIPTION ALARM BELL MBA-624 BACK BOX BBX-4 Optional (To be ordered separately) Weight 680g 300g Material Gong : Steel (Red) Housing : ABS Plastic Light Alloy (Painted Red) Rated Voltage 24 VDC - Rated Current ≤ 20 mA - Voltage Range 19.2 to 28.8 VDC - Sound Level 95 dB at 3m (10 ft.) - The MBA series Alarm Bells are low-current, audible signaling devices for use in Fire Alarm Systems and other signaling applications to provide warning during emergencies. ALARM BELL Model MBA-624 Typical Bell Installation with optional Back Box Gong Hex Bolt Striker Housing Back Box (Optional) Gasket (Optional) The Bells are polarized for usage with supervision circuitry, with low current, high efficiency DC motor to drive the striker. The Bell Gong is made of steel, finished in red enamel paint with the mechanism enclosed in an ABS plastic housing. Back Box BBX-4 (To be ordered separately), could be used in conjunction with the Bell as an option for outdoor installation, or when weatherproof installation is required. Back Box BBX-4 For Outdoor Installation (To be ordered separately) 85.5mm Back Box BBX-4 Dimension 42mm 96mm Sq. 127mm 112mm 85.5mm 112mm Ø20mm (ؾ”) Cable Entry 146.5mm Ø7mm M4 TAP Hole Ø150mm 75mm 68mm 26mm 85.5mm Alarm Bell MBA-624 Dimension 119mm Sq. Base) Ø5mm
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Member
Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice.
Distributed By :-
Version : 16-09-2013
1. MEMBER
CERT NO.: 2001.1.0321
ISO 9001 : 2008
R
DESCRIPTION ALARM BELL
MBA-624
BACK BOX BBX-4 Optional
(To be ordered separately)
Weight 680g 300g
Material Gong : Steel (Red) Housing : ABS Plastic
Light Alloy (Painted Red)
Rated Voltage 24 VDC -
Rated Current ≤ 20 mA -
Voltage Range 19.2 to 28.8 VDC -
Sound Level 95 dB at 3m (10 ft.) -
The MBA series Alarm Bells are low-current, audible signaling devices for use in Fire Alarm Systems and other signaling applications to provide warning during emergencies.
ALARM BELL Model MBA-624
Typical Bell Installation with optional Back Box
Gong Hex Bolt
Striker
Housing
Back Box (Optional)
Gasket (Optional)
The Bells are polarized for usage with supervision circuitry, with low current, high efficiency DC motor to drive the striker. The Bell Gong is made of steel, finished in red enamel
paint with the mechanism enclosed in an ABS plastic housing.
Back Box BBX-4 (To be ordered separately), could be used in
conjunction with the Bell as an option for outdoor installation,
or when weatherproof installation is required.
Back Box BBX-4 For Outdoor Installation
(To be ordered separately)
85.5
mm
Back Box BBX-4 Dimension
42mm
96m
m S
q.
127mm
112mm
85.5mm
112m
m
Ø20mm (ؾ”) Cable Entry
146.5mm
Ø7mm
M4 TAP Hole
Ø150mm
75mm
68mm
26mm
85.5
mm
Alarm Bell MBA-624 Dimension
119m
m S
q. B
ase)
Ø5mm
Technical Specifications
Operating Voltage 24VDC (Range 20VDC to 28VDC)
Operating Current Standby Current : 18mA
Alarm Current : 33mA
Detection Range Distance from 8m to 100m
Monitoring Area Maximum Area : 14 x 100 = 1400m2
Maximum Width : 14m
Wiring Non-Polarized Two-Core 24VDC
Non-Polarized Two-Core Detection Loop
Operating Environment
Temperature Range : -10C ~ +55C
Relative Humidity : 95% Non-condensation
Weight 650 Gram (with Mounting Bracket)
Material ABS Plastic
IP Rating IP30
Colour White with Black Screen
MULTRON Reflective Beam Detector is a reflective infrared beam smoke detector, which
must be used together with reflectors. The number of reflector(s) to be used (1 to 4) depends on the distance of coverage from the detector.
With built-in microprocessor, the detector has capabilities of analysis and judgment. The detector can automatically carry out system adjustment & compensation due to variations in ambience data through fixed algorithm.
The detectors can be used with all major brands of Conventional Fire Alarm Panels.
Hassle free alignment, using built-in digital guide display with Laser Beam
Auto-compensation for weaken receiving signals
Fire & Fault Interfacing Relay Output
Users’ programmable sensitivity
Self-diagnostic for internal faults
Designed in compliance to EN 54-12: 2002 Standards
Standard Accessories :-
1 pc. Mounting Bracket
1 pc. IR Light Filter (for site testing simulations)
4 pcs. Reflector
Reflective Beam Detector Model: DET-640RB
Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice.
The range of Heat and Smoke Detectors are designed to comply with EN54 Part 5 & Part 7 respectively. With low profile attractive appearance, the detectors have stable and reliable performance against false alarm.
Optical Smoke Detector, Model DET-C631
It is suitable for general smoke detection, particularly effective in detecting large visible smoke particles such as those produced by smouldering wood, paper, PVC or polyurethane foam.
The smoke detector detects fire by the scattering of infrared beam, which circuits are consisted of a infrared beam emitter and receiver. The emitting and receiving lens are in the optical sensing chamber, screening any interference from outside lights, without preventing the entrance of smoke particles. In a smokeless condition, it only receives very weak infrared light. When smoke particles enter the chamber, the received light signal will increased due to scattering. When the smoke reaches a predetermined density, it will trigger an alarm signal.
To reduce interference and power consumption, pulsed emitting circuits are used to increase the life of the emitting lens.
Heat Detector, Model DET-C632 Combination Rate of Rise & Fixed Temperature
With a combination of detecting Rate-of-Rise and Fixed Temperature for higher safety, this detector is ideal for general fire detection purposes.
Rate-of-Rise Heat Detectors are particularly suited in areas where the temperature is normally fairly stable – useful for low ambient temperature areas where the response of fixed temperature may be slower. It activates upon rapid rise in temperature.
Fixed Temperature Heat Detectors are particularly suited to areas where temperature can fluctuate for natural reason – e.g. where there are large windows or industrial heat producing processes. It is preset to trigger an alarm
when the temperature reaches approximately 57C – therefore an excellent way of avoiding continual false alarms in areas where the temperature fluctuates rapidly.
Electronic thermistor type detector element provides high accuracy with no moving parts, which results in excellence reliability.
Standard Base, Model DB-6
This common base can be used for all the Point Detectors in the C600 Series.
With no electronics, this mounting base provides durable trouble-free operation and ease of use when replacement of the detector head is required.
Features :-
Wide operating voltage for both Fire & Security Systems
Error free non- polarized zone input termination
Optional Detector Head locking mechanism incorporated
Twin colour LED Indicator, with `Green’ (blinking) for Normal Operation, and `Red’ for Alarm Status
LPCB Approved
Optical Smoke Detector
Model : DET-C631
Heat Detector R.O.R & Fixed Temp.
Model : DET-C632
Standard Base
Model : DB-6
0832-CPD-2118 1148a / 01
0832-CPD-2119 1148b / 01
Smoke & Heat Detector Model : DET-C631 and DET-C632
Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice.
Operating Voltage 9.6 VDC to 30 VDC 9.6 VDC to 30 VDC
Quiescent Current ≤ 65uA ≤ 35uA
Alarm Current 18 to 22mA (Typical 20mA) 18 to 22mA (Typical 20mA)
Remote LED Drive Current Output Max. 20mA Max. 20mA
Maximum Air Velocity 7.6 m/s -
Weight 102g (160g with Base DB-6 ) 85g (143g with Base DB-6 )
Operating Temp. Range -10°C to +50°C
Relative Humidity 95%RH, Non Condensing @ 40°C
Alarm LED Indication Red ( Continuous )
Normal LED Indication Green ( Blinking )
Ingress Protection IP42 IP42
Material of Body ABS Plastic ( To UL94V-0 Flammability Test Standards )
Colour of Body White
Standards EN54-7 EN54-5
Typical Detector Dimension
Heat Detector Model : DET-C632
Smoke Detector
Model : DET-C631
Ø100 mm
56
mm
48
mm
8
mm
Ø100 mm
52
mm
44
mm
8
mm
Optional – Remote LED
Typical Detector Termination Diagram
End-of-Line Resistor
1 2
5
3
8 6 7
4 1 2
5
3
8 6 7
4
+
-
Detection Zone Termination
FIRE ALARM PANEL
Manual Call Point Model : MCP-C652
The Manual Call Point MCP-C652 is provided to manually trigger the Fire Alarm System. They are constructed in red ABS plastic housing, and are usually installed in areas like corridors and exit staircases.
They are alarm latching, with LED alarm indication provided as standard. Every unit is provided with a special `Key’ to facilitate the resetting of the unit during testing or routine inspection.
Features :-
Complies to the latest EN 54-11 Standards
Non-breaking resettable `Glass’ via special key
LED light provided to indicate activation
Plug-in type of Termination for ease of Installation
Optional Transparent Flip Cover available
(To be ordered separately)
Technical Specifications :-
Operation Voltage 24VDC
Monitoring Currently 0mA
Alarm Current 46.3mA @ 24VDC
Operating Temperature -10 °C to +55°C
Relative Humidity 95%, Non-Condensing
Ingress Protection IP 43
Dimension in mm. (Ht. x Width x Depth)
89.5 x 87 x 26 (without Back Box) 89.5 x 87 x 58 (with Back Box)
Weight 137g (with Back Box) 84g (without Back Box)
Alarm Contact (Terminal 1,2 and 3,4)
470 Ω with LED
Alarm Contact (Terminal 5,6 and 7,8)
N/O without Resistor & LED
Manual Call Point , Model : MCP-C652
Convenient Plug-in Terminals for ease of wiring installation
TYPICAL TERMINATION DIAGRAM (Using Terminal 1,2 and 3,4)
FIRE ALARM PANEL
Zone Termination End-of-Line
Resistor -
+
Transparent Flip Cover may be added for extra protection
against accidental activation (Optional - To Be Ordered Separately)
LED N/O Contact 470 Ω
1 2 - -
3 4 + +
5 6 - -
7 8 + +
Typical Circuitry
Manual Call Point Model : MCP-C652
TO ACTIVATE ALARM :-
TO `RESET’ MANUAL CALL POINT :-
Innovative Resettable `Break-glass’…..
….with the look and feel of a real Break-glass, but without the trouble of replacement after activation....
1) Manual Call Point in its normal condition. 2) Position your finger onto the centre of the Break-glass’.
Position Finger onto `Break-glass’
6) To reset, insert the special Key at the bottom reset keyhole of the Manual Call Point.
7) Slid down the casing of the Manual Call Point downwards to reset the position of the `Break-glass’.
8) Press and slid back the casing to its original position. 9) Once the casing is snapped back, the Manual Call Point is properly `Reset’ to its normal condition.
3) To activate, press the `Break-glass’ and it will snap backwards. 4) Yellow marking will be shown at the top to indicate activation. 5) The Alarm Contact Signal shall be activated.
Press Hard to Activate.
The Yellow Marking will be shown once the Call Point is activated.
Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice. Version : 1-08-2016
Customisation is available to meet any special requirement
Colour Symbols & Indicators for ease of identification & usage
The CFP-600 Series of Fire Alarm Panel uses the latest in
microprocessor technology to meet today’s stringent needs for a
comprehensive and versatile range of Fire Detection & Alarm Systems.
Design for ease in installation and operation, the control functions and
programming are enables through a key switch to prevent unauthorized
access. Operation of the Panel is made simple with frontal indications
and switches.
Design in compliance to EN54 Parts 2 & 4, each detection zone can
cater up to 20 conventional devices.
Attractively styled and compact in size to blend into any modern
architecture, the slim profile of the panel is unobtrusive even when
surface mounted.
MULTRON®
Model No. Zoning
CFP-600- 4 4- Zone
CFP-600- 8 8-Zone
CFP-600-12 12-Zone
CFP-600-16 16-Zone
CFP-600-20 20-Zone
CFP-600-24 24-Zone
The standard Fire Alarm Panel lowest capacity is 4-Zone, with increment in steps of 4-zone up to a capacity of 24- Zone. Panels requirement above 24-Zone may be customised and made to order based on clients’ requirement. Panels in Weatherproof Cabinets are also available upon request.
TYPICAL FIRE ALARM PANEL PHYSICAL DIMENSION
Zone Module (4 zone per Module)
Door Lock
Mains Module
Ø20mm Knock-Out Holes For Cable Entry
20 to 24-Zone
12 to 16-Zone
350mm 135mm
46
0m
m (
12
to
16
-zo
ne)
38
0m
m (
4 t
o 8
-zo
ne
)
54
0m
m (
20
to
24
-zo
ne)
Technical Specifications :-
Mains Voltage 230VAC ± 15% @ 50 Hz
System Operating Voltage 24VDC ± 15%
Detection Circuit Static Current 2.4mA (Based on 20 conventional detectors)
Resistance for Alarm Activation 100Ω to 1.4KΩ
End-of-Line Resistor 4.7KΩ
Sounder Output Circuit 1 amp (Total Current Output)
`Alarm’ Output Contact NO or NC Voltage-Free Contact (Selectable)
`Fault’ Output Contact NO or NC Voltage-Free Contact (Selectable)
Aux. Power Output 0.5amp @ 24VDC
Operating Temperature -10°C to 45°C
Relative Humidity 95%, Non-Condensing
IP Rating IP30
Estimated Weight (Excluding Standby Batteries)
4 and 8 zone : 6.3 kg 12 and 16 zone : 7.5 kg 20 and 24 zone : 8.7 kg
The electronics components are mounted onto the PCBs by the latest surface mount technologies.
PCBs within the panel are easily accessible and connected by ribbon cables, with knockout holes for cable entry provided for ease of wiring installation and termination.
The modular construction of the Panels enables easy replacement of any faulty parts or modules, with the flexibility for any re-configuration.
THE PANELS ARE MANUFACTURED UNDER STRICT ISO 9001 QUALITY MANAGEMENT SYSTEM CERTIFIED BY ACCREDITED CERTIFICATION BODY
ZONE MODULE, CFP-600-ZM
Each Zone Module incorporates 4 Detection Zones, with each zone having an independent `FIRE’ (Red), and `FAULT’ (Yellow) LED Indicators
`DISABLE’ Pushbutton with corresponding LED Indicator is provided for each zone.
`DISABLE’ Pushbutton With LED Indicator
Zone Label (Slide-in from Behind)
`Fire’ & `Fault’ LED Status Indicator
Agent Release Countdown Timer
AGENT RELEASE MODULE, CFP-600-GM
The Agent Release Module may be incorporated into the Fire Alarm Panel for Extinguishing Agent Release Functions.
Typical examples are for usage in CO2, FM200, Foam or Pre-Action Sprinkler Systems. This Module can be factory programmed to work in conjunction with any 2 Alarm Detection Zones for Cross-Zone Detection prior to Agent release.
Zone Label (Slide-in from Behind)
Abort Pushbutton
Manual Release Pushbutton
Fault LED Indicators
MAINS MODULE, CFP-600-MM
The Mains Module provides all the Status Indicators, Control Pushbuttons, and Control Access Key Switch for Fire Alarm System.
The Series CFP 601 Fire Alarm Control Panel are developed from single-chip microprocessor, to meet the needs for a comprehensive and versatile range of Fire Detection & Alarm Systems. Design for ease in installation and operation, the Panel is made simple with frontal indications and switches, and a lockable front door as protection against unauthorized access. The Panel is design in compliance to NFPA requirement, with each Detection Zone catering up to 20 conventional devices. Attractively styled and compact in size to blend into any modern architecture, the slim profile of the panel is unobtrusive even when surface mounted.
Features :-
Alarm, Trouble & Supervisory, Relay Output
3 amp Power Supply c/w Resettable & Non-Resettable 24VDC Output
Short Circuit at Zone Input can be set as `Alarm’ or `Fault’ status
Programmable to Disable / Enable each Zone
Programmable to Disable / Enable Sound Output
Two Supervisory Input with 12VDC Output
FIRE ALARM PANEL (Conventional Type)
Series CFP 601
Model No. Number of
Detection Zone Number of
Sounder Output Dimension (mm) Weight
CFP 601- 4 4 zone 1
400H x 350W x 115D 6.0kg
(without Battery) CFP 601- 8 8 zone 2
CFP 601-16 16 zone 4
Technical Specifications :-
AC Power : 220VAC, 50Hz
Battery Maximum Charging :- 27.6VDC @ 0.8 Amp
Maximum Battery Charger Capacity :- 18AH Battery (Sealed Lead Acid Type)
Total System Power : 24VD , 3.0Amp
Output Relay rated at 2.0 Amps @ 30VDC
End-of-Line Resistor : 4.7 KΩ, ½W
Member
Due to constant improvement in our products, we reserved the right to modify or withdraw any product or service without prior notice.
Distributed By :-
Version : 12-05-2013
1. MEMBER
CERT NO.: 2001.1.0321
ISO 9001 : 2008
Typical 16 zone Panel Facial and Termination Board Layout
(Optional)
The CFP 602 series Fire Alarm Control Panels are developed from single-chip microprocessor, to meet the needs for a comprehensive and versatile range of Fire Detection & Alarm Systems. Design for ease in installation and operation, the Panel is made simple with frontal indications and switches, and a lockable front door with Key Switch as protection against unauthorized access. The Panel is design in compliance to EN54 Part 2 & 4 requirement, with each Detection Zone catering up to 20 conventional devices. Attractively styled and compact in size to blend into any modern architecture, the slim profile of the panel is unobtrusive even when surface mounted.
Features :-
2 x Alarm, & 1 x Fault Relay Output
2 x Sounder Output
Zone Short Circuit `Fault’ status provided
Programmable to Disable / Enable each Zone
Programmable to Disable / Enable Sound Output
In compliance to EN54 Part 2 & 4 requirement
FIRE ALARM PANEL (Conventional Type)
Series CFP 602
Model No. Number of
Detection Zone Dimension (mm)
Approximate Weight
CFP 602 - 4 4 zone
265H x 335W x 87D 2.7 kg (without Battery)
6.7 kg (with 7AH Battery)
CFP 602 - 8 8 zone
CFP 602 - 12 12 zone
CFP 602 - 16 16 zone
Technical Specifications :-
AC Power : 230VAC, 50Hz
Battery Maximum Charging :- 28VDC @ 0.3 Amp
Maximum Battery Charger Capacity :- 7AH Battery (Sealed Lead Acid Type)
Output Relay rated at 1.0 Amps @ 30VDC
Zoning End-of-Line Resistor : 3.3 KΩ, ½W
Member