Top Banner
The sensor makes the difference Quantitative Radiography for Medical, Dental and Industrial Imaging Applications, enabled by Dose Efficient Direct Conversion CdTe Crystal X-Ray Imaging Sensors
23
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Quantitative Radiography for Medical, Dental and Industrial Imaging Applications, enabled by Dose Efficient Direct Conversion CdTe Crystal X-Ray Imaging Sensors

Page 2: Ajat presentation  at VTT sense13 2013

2

History & Facts– Founded in 2001 in Otaniemi ( VTT/Micronova)

– Acquired by XCounter AB June 2010

– Annual Yearly Growth 20%

– 10% Global Market Share Digital Dental X-ray Sensors

– 45 employees & advanced robotics (we are hiring!)

– 28 approved patent families with 61 individual patents within Xcounter

AB Group)

Page 3: Ajat presentation  at VTT sense13 2013

3

2D/3D Dental X-raysystems Medical X-ray systems

Small animalCT system

X-ray food inspection systems

Canseam

scanner

Weld inspection

Non Destructive Testing (NDT) of

industrial components,

Applications

Page 4: Ajat presentation  at VTT sense13 2013

4

Technology

– CdTe Crystal-CMOS

– DQE: >90% at 90kVp

– MTF: >75% at 2lp/mm

and >40% at 5lp/mm

– 3X better DQE =3X

Better Image Quality

– 3X more dose efficientt

Page 5: Ajat presentation  at VTT sense13 2013

Patented CdTe Crystal Sensors

5

100µm

Page 6: Ajat presentation  at VTT sense13 2013

6

Page 7: Ajat presentation  at VTT sense13 2013

DQE Detective Quantum Efficiency

7

Page 8: Ajat presentation  at VTT sense13 2013

MTF Modulation Transfer Function

8

Page 9: Ajat presentation  at VTT sense13 2013

Linear Dose Efficient Medical X-ray Scanning

XCAN AG

Page 10: Ajat presentation  at VTT sense13 2013

Low dose 3D X-ray CT-imaging for Breast Imaging

CT Imaging GmbH

Page 11: Ajat presentation  at VTT sense13 2013

50µm voxels

11

Page 12: Ajat presentation  at VTT sense13 2013

Medical and Pharma Quality Control

12

Page 13: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Pharmaceutical Quality Control

Images by InnospeXion©

Page 14: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Medical Product Quality Control

Images by InnospeXion©

Page 15: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Food Manufacturing Process Control

Images by InnospeXion©

Page 16: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Food Manufacturing Process Control

Images by InnospeXion©

Page 17: Ajat presentation  at VTT sense13 2013

Packaged Fish Processing

The sensor makes the difference!

Images by InnospeXion© in VALKA systems

Page 18: Ajat presentation  at VTT sense13 2013

Images by InnospeXion

Oil & Gas Pipe Weld Inspection

DR-CR.RU ApplusRTD RayScan

Page 19: Ajat presentation  at VTT sense13 2013

Nuclear Power Safety Critical Pipe Inspection

Quantitative Radiographic Tomography technology for the in-situ Inspection of welded austenitic pipework. ENIQ Qualified

Page 20: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Thank You!

[email protected]

Page 21: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

FDA Recalls, Market Withdrawals, & Safety Alertshttp://www.fda.gov/Safety/Recalls/default.htm

CDC Foodborne Disease Outbreak Surveillancehttp://www.cdc.gov/outbreaknet/surveillance_data.html

The Counterfeit Drug Problem http://www.phrma.org/counterfeit-drugs

The Food Waste Reduction Alliance (FWRA)http://www.foodwastealliance.org/

FDA Food Safety Modernization Act (FSMA)http://www.fda.gov/Food/GuidanceRegulation/FSMA/default.htm

FDA Pharmaceutical cGMPs for the 21st Century - A Risk-Based Approachhttp://www.fda.gov/Drugs/DevelopmentApprovalProcess/Manufacturing/QuestionsandAnswersonCurrentGoodManufacturingPracticescGMPforDrugs/ucm137175.htm

References and Sources for more information

Page 22: Ajat presentation  at VTT sense13 2013

The sensor makes the difference!

Global Food Safety Initiativehttp://www.mygfsi.com/

ASTM International Committee E55 on Manufacture of Pharmaceutical Products http://www.astm.org/COMMITTEE/E55.htm

International Conference on Harmonisation (ICH)http://www.ich.org/

Foundation for Food Safety Certificationhttp://www.fssc22000.com/

BRC Global Standard for Food Safety Issue 6 http://www.brcglobalstandards.com/globalstandards/standards/food.aspx

Next Generation X-ray Imaging solutions by Innospexion http://www.innospexion.dk/

References and Sources for more information

Page 23: Ajat presentation  at VTT sense13 2013

References and Sources for more information

• CT Imaging www.ct-imaging.de/• German Federal Institute for Materials

Research and Testing http://www.bam.de/• Digital Radiography www.dr-cr.ru• Terwingo www.terwingo.ru/• TOMOWELD FP7/2007-2013

www.tomoweld.eu• ApplusRTD http://www.applusrtd.com/