This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
201www.conceptcontrols.com
AIR QUALITYINSTRUMENTS
201
Handheld AnamometersAnemomaster LITE 6006 202Compact and Lightweight Hotwire Anemometer 202Anemomaster Professional / Standard 6036/6035 202Climomaster 6501 203Anemomaster 6812, 6813, 6815 204Anemomaster 6113 204TABmaster 6710 205Anemomaster 6162 205
Anemomaster Professional / Standard 6036/6035Features:
• Simultaneously measures and displays air velocity and air temperature
• Telescopic articulating probe makes it easy to take traverse measurements at ceiling ducts and other hard to reach places
• Datalogging function with storage capacity of up to 1500 records which allows users to work longer before pausing to upload data to a PC. (Model 6036)
• USB connection, easy to upload to your PC or laptop. (Model 6036)
• Highly Visible blacklit display• The new Anemomaster offers an optional hands-free case
that can be comfortably worn by the contractor
Specifications:
Model Model 6036 Model 6035Probe Type Telescopic and
Articulating TipTelescopic
Air Velocity Range 2 to 6,000 FPM (0.01 to 30.0 m/s)
Accuracy +/- 3.0% of reading or 0.015 m/s whichever is greater
Standard Accessories Carrying Case, Operation Manual, AA Batteries, AC AdapterNIST Certificate
Options Analog Output, Pressure sensor option, Portable Printer, Printer Cable, Rolled Paper for printer
NEWNEW
203www.conceptcontrols.com
Climomaster 6501Most Accurate Hot-Wire Anemometer of its Kind
Features:• Probe Compatibility feature allows you to have spare probes• Automatic Flow Rate Calculation function• USB connection to PC• Large data storage, stores up to 20,000 measurements• Differential Pressure available as an option• One probe simultaneously measures air velocity, air temperature, relative humidity, and airflow rate• 7 different detachable probes available, including a low air velocity, omni-directional probe• Detachable probes allow you to share the main unit or the probes• Optional Software displays real-time measurements in table, graphic, and spreadsheet formats
Specifications:
Model 6531 6541 6542 6551 6552 6533 6543 6561Air Velocity Range 20 to 6000 fpm (0.10 to 30.0 m/s) 10 to 1000 fpm 20 to 9840
fpm (0.05 to 5.00 m/s) (0.1 to 50
m/s)Accuracy +/- (2% of reading +/- 0.0125) m/s
Air Temperature Range -4 to 158°F (-20 to 70°C)Accuracy +/- 1°F (+/- 0.5 °C)
Relative Humidity Range 2 to 98%RH (Model A531, A533)Accuracy +/- 2 %RH
Differential Pressure(Option)
Range -5.00 to +5.00 kPaAccuracy +/- (3% of reading +0.01) kPa
Output Digital USBAnalog DC 0 to 1 V (Option)
Datalogging Stores up to 20,000 measurement dataPower Supply 6 x AA Batteries / AC Adapter (100 to 240 V)Weight 0.9 lbs (400 g)Standard Accessories Carrying Case, Operation Manual, AA Batteries, 2m Probe Cable, NIST CertificateOption Spare Probes, Analog Output, Pressure Sensor, Extention Rod Printer, Printer Cable, PC Communcation Cable,
Windows Software, AC Adapter
Probe Options:
Probe 6531 6541 6561 6542 6533 6543 6551 6552Probe Tip
Applications HVAC Testing, IAQ Investigation
HVAC Testing High Velocity Applications
HVAC Testing, Manufacturing
Process Control
Cleanroom Certification, HEPA Filter
Performance Testing,
Turbulent Air Testing
Cleanroom Certification, HEPA Filter
Performance Testing,
Turbulent Air Testing
Heat Sink Cooling
Efficiency Testing, Airflow Measurements in tight spaces
Heat Sink Cooling
Efficiency Testing, Airflow Measurements in tight spaces
Features:• HVAC Testing• IAQ Investigations• Industrial Hygiene• Cleanroom Testing• Display switchable in m/s (MPS)
or ft/min (FPM) forair velocity and cubic ft/min (CFM) or cubic metre/hr (CMH) for calculated air volume flow. Very high accuracy due to use of microprocessor digital memory for maximum and minimum values
• Average measurements over two or sixteen seconds for air velocity
• Display hold for easy reading of measurements• Long battery life
Specifications: Model 6812 6813 6815 Air Velocity Probe AP275 40 to 7800 FPM (0.2 to 40 m/s)
Probe AP100 60 to 6800 FPM (0.3 to 35 m/s) Accuracy ±1.0% of Reading ±1 digit Resolution 1 FPM or 0.01 m/s
Temp. Air Velocity Probe
- -22 to 212 F (-30 to 100C)
Optional Temp Probe
- -139 to 392 F (-95 to 200C)
Accuracy - ±0.3o±0.2% of Reading in oF
Resolution - 0.1 F or 0.1o(1 F below -99.9 F)
Relative Humidity
Range - 5.0 to 95.0 %RH
Accuracy - ±2.0 %RH Resolution - 0.1 %RH
Display 0.5 inch LCD, 4 digits with LED Backlight
Operating Temp.
Instrument: 32 to 125F (0 to 50C)
Probe: -4 to 212F (-20 to 100C) Power Supply 3 AA Alkaline Batteries Operating Time (Battery)
Approximately 150 hours
Dimensions Instrument W 3.2 x D 1.5 x H 6.5 inches (8.2 x 3.8 x 16.5 cm)
Probe AP275 2.75 inch diameter Probe AP100 1.00 inch diameter RH/Temp Probe
- 6 inch x 1 inch diameter
Standard Accessories 1 x Rotating Vane Probe Head, your choice of AP275 or AP100 3 x AA 1.5V Alkaline Batteries, Operation Manual,
Carrying Case Extension Rod w/ Handle Grip, Flexible Rod HTP 201
combination RH / Temp Probe (avail. for 6815)
Anemomaster 6113Multi-Function Thermal Anemometer
Features:• Probe Compatibility feature
allows utilization of a spare probe
• Simultaneously measures air velocity, temperature, and pressure measurements
• Large, easy-to-read LCD• Quick printing of measurements at site• Simple operation with buttons for printing and calculation• Easily keeps record of measurements• Suitable for measurements inside ducts
Specifications:
Air Velocity Range 20 to 9840 fpm (0.10 to 50.0 m/s) Accuracy +/-(3% of reading +20fpm (0.1m/s))
Air Temp. Range 32 to 212ºF (0 to 100ºC) Accuracy +/-2.0ºF (1.0ºC)
Pressure (Option)
Range -5.00 to +5.00kPa Accuracy +/-(3% of reading +0.01)kPa
Measuring Functions
Settings Display hold, time constant setting (1, 5, or 10 sec.), remaining battery life (5 steps), measuring unit setting (m/s, fpm, Celsius, Fahrenheit, kPa).
Data Storage Instantaneous storage, average (over 60 sec max), Storage 100 max
Calculation Max. and min. values, averaging, raw data display
Display Calendar function, air velocity bar graph display
Outputs Digital Output
RS-232C (4800, 9600, 19200, 38400bps) for communication w/ PC
Printer Output
Printing calculation results and measurements
Analog Output (Option)
DC 0 to 1V (1ch. Selected from air velocity, temp. and pressure)
Power Supply 6 × 1.5 volt C cells (Mn, alkaline, or Ni-Cd)
Battery Life 10 hours continuous operation (with alkaline batteries, at 5m/s, 20ºC, without printer use)
Operating Environment
Main Body 41 to 104ºF (5 to 40ºC) Probe 32 to 212ºF (0 to 100ºC)
Storage Environment 41 to 104ºF (5 to 40ºC) Weight (incl. batteries) Approx. 2.2 lbs (Approx. 1000 g) Dimensions 7.9”x5.9”x3.9” (200x150x100mm) Standard Kit 1 x operation manual, 6 x 1.5V Mn C
cells, 1 x probe with 2-meter (6.6-feet) cable, 1 x extension rod, 1 x shoulder strap
Optional Accessories Spare Probe, Analog Output, Pressure Measurement, Printer Paper, Communication Cable, Data Management Software, AC Adapter
205www.conceptcontrols.com
HANDHELD ANAMOMETERS
Anemomaster 6162Middle and High Temperature Anemometer
Features:• Simultaneous display of air velocity
and temperature• Improved response time by the
addition of secondary temperature compensation circuit
• Easy review of time history by graphic display• Memory function of maximum 999 separate measurement
data• RS-232 C serial interface for connection to PC. Analog
output, and remote control terminal equipped• Probe Compatibility feature allows you to change the
Display Digital (simultaneous display of air velocity and temp) Input/output Terminal
Remote terminal: START/STOP key Analog output terminal: Output voltage 0 . 1 V, Output
impedance 47. Digital output terminal: RS-232C (serial interface)
Power Supply Dry battery drive: US type (1.5V x 6 pcs = 9V), Alkaline battery, Mn battery AC adapter: 12.5V, 450mA
(AC100V +/- 10%, 50/60Hz) Operating Temp.
41-104oF (5-40oC)
Battery Life Approx. 8 hours Dimensions 8.7” x 3.3” x 5.9” 220 x 85 x 150 mm Weight Main body: Approx. 4.0lbs (1.8kg), Probe Model 0203:
7.1oz(200g), Model 0204: 17.6oz (500g)
TABmaster 6710Capture Hood
The TABmaster is the perfect tool for accurate supply and return airflow measurements. Interchangeable hoods make it a snap to sample the air for any duct size. The unit is lightweight and easy to handle.The full colour screen can be tilted so it’s always at the optimal viewing angle regardless of height.
Features:• 23 to 2500 cfm (40 to 4250 m3/h) range• Simultaneously measures and displays air flow,
temperature and humidity• Displays the direction of the airflow as well as the velocity• Store up to 3,000 measurements• Advanced storage feature allows you to store multiple
measurements under a single ID#• Easy one-person setup and use• Five hood sizes make it easy to pick one that fits your duct• Built-in back pressure compensation ensures accuracy for
large volumetric flow measurements• Competitive economic price with professional-grade
features
Specifications:
Airflow Measuring Range 23 to 2500 CFM (40 to 4250 m3/h)
Accuracy 3% of measuring +/- 10 m3/h
Resolution 1 m3/h
Temperature Measuring Range 32 to 122°F (0 to 50°C)
Dimensions 16.9” x 19.6” x 5.5” (430 x 500 x 140 mm)
8.9” x 12.8” x 5.5” (226 x 325 x 140mm)
Weight Approx. 22lbs (10kg) Approx. 11lbs (5kg)
4 Channel Anemomaster 1570Features:
• 4CH simultaneous measurement in a compact body• Wide probe selection available for various applications• Can take measurements at high-time-resolution (0.1 sec)• RS232C terminal for data logging• Channel display can be switched by the touch of a button• Probe compatibility saves downtime and shipping cost• Windows software gives you simultaneous measurement
on air velocity and flow rate• Measurement data saved in text format for easy
processing using other software such as Excel
Main Body Specifications:
Display LCD display Data Transfer Burst Mode Transfers data of all channels
Channel Mode Transfers data of specific channel only
Software Function
Instant Mode Displays instantaneous values every specified sampling time
Average Mode Displays average values of a specified sampling time
Output Digital RS 232C (Baud rate 9600bps fixed)
Analog 0-5 V Main Body Operation Temp. 41-104ºF (5-40ºC) External Dimensions 7.8” x 10.2” x 2.8” (200 x 260
x 70mm) Weight 5.7 lbs (Approx. 2.6 kg) Power Supply AC 85V – 276V 50Hz/60Hz Standard Kit RS-232 cable, Power cable,
• Simultaneously measures and data logs multiple parameters such as: CO, CO2, temperature, relative humidity, to monitor indoor air quality conditions
• Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air
• Built-in memory allows user to store multiple point measurements. Equipped with RS232C terminal
• Easy user calibration with built-in calibration function• Capable to continuously monitor parameters via PC• Large LCD shows multiple parameters at a glance
Specifications:
CO Range 0 to 500PPM
Accuracy +/-3% of reading or +/-3PPM whichever is greater
Resolution 0.1PPM: 0-99PPM 1PPM: 100-500 PPM
CO2 Range 0 to 5000PPM
Accuracy +/-3% of reading or+/-50PPM whichever is greater
Resolution 1PPM
Temp. Range - 4 to 140F (-20 to 60C)
Accuracy +/- 1F (+/-0.5C)
Resolution 0.1F (0.1C )
Relative Humidity
Range 2 to 98%RH
Accuracy 2 to 80%RH:±2%RH, 80 to 98%RH:±3%RH
Resolution 0.1%RH
Function Normal Mode Normal measuring (do not store and calculate the data). Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity and Humidity Ratio.
Calculation Mode
Store the data, and calculate the maximum, minimum and average value.
% OA Mode Measure ventilation ratio (Ask for ventilation ratio by calculating from temperature and CO2 value).
Data Output Mode
Perform re-calculation of stored data and output of data to PC and Printer.
Calibration Mode
Perform the calibration of CO and CO2.
Output Digital RS232C
Analog (option)
DC 0 to 1V
iaQ & environmental monitors
Thermohygrometer Model 6841Features:
• Ultralight and palm-size• Easy to use (Select
temperature, humidity, or power on/off)
Specifications:
Measuring Object Clean airflow
Measuring range Temperature -4 to 113ºF (-20 to 45ºC)
Humidity 5 to 95%RH
Display resolution Temperature 0.1ºF or 0.1ºC
Humidity 0.1%RH
Accuracy Temperature +/-0.9ºF (+/-0.5ºC)
Humidity +/-3%RH
Responsiveness 30 sec
Measuring Function Conversion between ºF and ºC
Dimension Main Unit Approx. 2.4” x 4.7” x 1.3” (60 x 120 x 34mm)
Probe Approx. φ19 x 170mm
Cable Approx. φ3.3 x 1.5m
Power Supply AAA Battery x 4 (Mn, Alkaline, or Ni-Cd)
Operating Environment
Main Unit 41 to 104ºF (5 to 40ºC)
Probe -4 to 113ºF (-20 to 45ºC)
Storage Temperature
14 to 122ºF (-10 to 50ºC)
Weight (including batteries) Approx. 6.3oz (180g)
Accessories Operation Manual, AA batteries
Options Carrying Case
IAQ & ENVIRONMENTAL MONITORS
AIR QUALITY
208 www.conceptcontrols.com
Air Aide AA-3500Handheld Odor Monitor OMXFeatures:
• Numerical value for relative strength of smell
• Numerical value for classification of smell
• Handheld odor meter is ideal for before and after applications, such as air purification and cleaning service.
• Memory sampling mode saves data based on the selected sampling rate. (up to 32732 data, 511 files)
• Battery operated with 7 hrs continuous usage
Specifications:
Model OMX-SRM OMX-ADM OMX-TDMDetection Method
Two Semiconductor Gas Sensors
Sampling Method
Continuous Sampling with Built-in Air Pump
Object Gas Ethanol, Acetone,
Hydrogen, etc
Hydrogen Sulfide, Methyl
Mercaptan, Ammonia, etc
TVOC (Toluene), etc
Odor Strength Level
0.0 to 999 0 to 999 0.0 to 9999 (µg/m3)
Classification Class 0 to 90 Odor Intensity 2.5 to 5.0
n/a
Power Supply 4 x AA batteries or AC adaptor *Battery life for continuous measurement is approx. 7 hours
Memory Capacity
Up to 32732 data
Storage Temperature
0 to 40 ºC (32 to 104 ºF) * No condensation
Operating Temperature
-10 to 50 ºC (14 to 122 ºF) * No condensation
Dimensions 74 (W) x 167.5 (L) x 35 (H) mm
Weight 250g (without batteries)
The Air-Aide AA-3500 Airborne Particulate Monitor provides accurate and instantaneous display of concentration readings on lung damaging particulates and aerosols. AA-3500 is a portable handheld survey tool for measuring lung damaging particulate matter. The unique sensor design has applications in indoor air quality (IAQ), HVAC, environmental and industrial hygiene. Results are immediately displayed and stored in memory. The supplied PC software allows for graphical and statistical representation of the total dust generating process, eliminating the need for repetitive and costly filter gravimetric laboratory analysis.
Features:• Direct reading with high resolutions and stability of airborne
particulates• Active sample flow using a long-life air sampling pump for
particle size separation• Location codes, user-defined audible alarm• Size selective inlet, PM-10, PM-2.5, PM-1.0 and ISO
respirable (4.0µm)• Rechargeable battery – unit runs on AC or DC power• Large data storage capacity – can run continuously for 15
months without downloading• On-screen programming of sampling and data storage
parameters• Downloading of stored data through an RS232 port; PC-
based software supplied to download and graph stored data• Selection of different built-in calibration factors for fine and
coarse particulate matter• CE, ETL approved• Optional Wireless Data Transmission to computer• Interfaces to wireless Video Dust Monitoring System Model
VDM-7500
Options:• Zero Filter• Calibration Span Reference insert• Size selective impactor: PM-10, PM-2.5, PM-1.0 and ISO
Respirable (4.0µm)
NEW
209www.conceptcontrols.com
EVM Environmental MonitorsThe 3M™ EVM Series monitors both particulates and air quality in one compact instrument. From healthcare and manufacturing to construction and military applications, the EVM Series provides a lower cost of ownership by combining three instruments into one. Its user-friendly interface, patented dial-in rotary impactor, and advanced reporting and analysis features make it a particulate and IAQ area monitoring instrument of choice for industrial hygienists and safety professionals worldwide.
Its large display and buttons, simple screens, straightforward commands and robust software solutions put all of the EVM-7’s capabilities right at your fingertips.
• Simultaneous Measurement of Particulate and Gas Concentrations Reduces the need for multiple instruments and lowers the cost of ownership.
• Dial-in Rotary Impactor Twist and click selection of particulate settings: PM2.5, PM4, PM10 or TSP.* Eliminates disassembly and reduces the need for external cyclones.
• 90° Light Scattering Photometer Provides real-time measurement of particulates.
• Built-in Sampling Pump for Gravimetric Analysis Allows user to insert a 25 or 37 mm cassette to capture particulates for laboratory testing. Incorporates the effects of protective clothing and personal physical condition.
Specifications:PART NO. DESCRIPTIONEVM-7 EVM-7 Advanced Particulate and Air Quality Monitor
Includes base model with PID Sensor, CO2 Sensor, one Dummy Sensor (used to seal socket when no sensor is present), two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-080 PID Cleaning Kit, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, 74-726 Toxic Calibration Adapter and 74-718 Storage Case. Also available with CO sensor. 3M ID 70-0715-8013-1
EVM-4 EVM-4 Indoor Air Quality Monitor
Includes base model with CO2 Sensor, two Dummy Sensors (used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 74-726 Toxic Calibration Adapter and 74-718 Storage Case. Also available with CO sensor. 3M ID 70-0715-8015-6
EVM-3 EVM-3 Real-Time Direct Reading Particulate Monitor
Includes base model with two 37mm Gravimetric Filter Cassettes (for pump protection; one in unit and one spare), three Dummy Sensors (used to seal socket when no sensor is present), 53-263 12V DC Universal Input Power Supply, 53-575 USB Cable, 100-456 Silicone Dielectric Grease for Impactors, 74-090 10 pack Pump Protection Filters, 74-720 Dust Zero Calibration Filter Assembly, and 74-718 Storage Case 3M ID 70-0715-8016-4
AIRPROBE-10-120
Airprobe-10 Air Velocity Probe Airprobe-10 Kit -Includes Airprobe-10, 74-719 Mounting Bracket, 74-083 Adapter Cable, 53-037 120V AC Charger and 54-964 Carrying Case 3M ID 70-0715-8017-2
AIRPROBE -10-220
Airprobe-10 Kit -Includes Airprobe-10, 74-719 Mounting Bracket, 74-083 Adapter Cable, 53-038 220V AC Charger and 54-964 Carrying Case 3M ID 70-0715-8018-0
3M™ EVM-3 Specializes in real-time direct reading of particulate concentrations. This tri-sensor instrument utilizes the built-in sampling pump and dial-in impactors for real-time mass concentration readings.
3M™ EVM-4Multi-sensor instrument designed for indoor air quality investigations. Simultaneously track, log and monitor multiple indoor air quality parameters including room air exchange rates and dew point.
EVM-4 measures:• Toxic Gas (choose from nine sensors)• Relative Humidity• Carbon Dioxide• Temperature
RENTALConcept Controls Inc.
IAQ & ENVIRONMENTAL MONITORS
AIR QUALITY
210 www.conceptcontrols.com
HAZ-SCANNER Indoor Environmental Monitoring StationThe portable HAZ-SCANNER Indoor Environmental Monitoring Station (IEMS) is designed to measure critical parameters for indoor environmental assessments, LEED green building certification, school zone measurements, job task analysis, and occupational health and safety compliance. The HAZ-SCANNER IEMS displays real-time readings with datalogging capabilities. Configure the IEMS for up to 14 simultaneous critical indoor measurements. Optional wireless data acquisition for continuous unattended sampling for up to one mile is available. Easily download data to a PC or Mac and create compliance-ready graphical reports with the supplied software.
Features:• Direct reading• Measures and displays data for up to 14 critical
air quality parameters• Standard IEMS configuration measures 5 parameters
including PM10 or TSP particulates, CO2, CO, temperature, and relative humidity
• Add one or all optional plug and play sensors and/or IEMS-specific meters (up to 9 sensors/meters total) Choose from additional toxic gas sensors, PID for VOCs, or IEMS-specific meters for light intensity, sound/noise, atomic/nuclear radiation, ELF radiation, and air velocity
• Available analog input port for alternative meter• Interchangeable size-selective impactors are available
for PM1.0, PM2.5, or PM4.0 (close approximation of respirable)
• In-line standard 37-mm or optional 25-mm gravimetric filter cassette provides concurrent filter sampling for chemical and biological analyses
• 1 to 4 L/min internal sample pump• 8-hour operation with NiMH battery, continuous
operation with AC power• Displays TWA, STEL, Max, and Min• Optional alarm indicator light and siren for
user-defined threshold limits• Removable handheld sensors for spot-checking remote
areas• Datalogging and optional real-time wireless
data transmission• Easy-to-use graph and reporting software — compatible
with PC and Mac
Description Cat. No.HAZ-SCANNER IEMS includes monitor with particulate sensor for TSP, impactor for PM10 sampling, CO2, CO, temperature, and relative humidity sensors, charger, HazComm Pro Software, cables, CD-ROM with instructions, and carry case
770-800
Requires calibration using appropriate calibration gas(es) and regulator sold separately
HAZ-SCANNER IEMS is expandable to up to 14 parameters; see sensors and meters listed below.
IEMS-specific Optional Meters (Choose up to 5)Each includes holder to mount meter on tripod accessory
Air Velocity Meter, 0 to 30 m/s or 0 to 5910 ft/min 770-801
Atomic/Nuclear Radiation Meter, 1 to 19,999 cpm or 0.001 to 100 mR/hr
770-802
ELF Radiation Meter, 1 to 200 mG 770-803
Indoor Light Intensity Meter, 0 to 50,000 lux/0 to 5000 footcandles
770-804
IEMS-specific Optional Sensors (Choose up to 4)†Nitrogen Dioxide Sensor, 0 to 20 ppm* 770-805
Sulfur Dioxide Sensor, 0 to 50 ppm* 770-806
Oxygen Sensor, 0 to 30%* 770-807
Ozone Sensor, 0 to 0.15 ppm* 770-808
Ozone Sensor, 0 to 5 ppm* 770-818
PID for VOCs, 0 to 2000 ppm (isobutylene equivalent) 770-809
AccessoriesSize-selective Impactors PM1.0 770-811
PM2.5 770-812
PM4.0 770-813
Calibration Standard, particulate 770-207
Calibration Regulator, 1.0 L/min fixed flow, male thread, for use with 34/58 L aluminum cylinder, required for use with calibrator gas for toxic gases
770-816
Tripod Stand for HAZ-SCANNER IEMS includes holder for IEMS
770-814
Alarm for HAZ-SCANNER IEMS 770-815
Wireless Radio Modem, 900 MHz, up to 300 feet 770-505
Wireless Radio Modem, 900 MHz, up to 1500 feet 770-505X† Hydrocarbon sensors and specialty sensors for nitric oxide, chlorine, hydrogen
cyanide, and hydrogen sulfide are available. Contact SKC; specify gas type when ordering.
* Additional calibration gas for the specific chemical is required when using additional toxic gas sensors.
Ordering Information
211www.conceptcontrols.com
IAQ & ENVIRONMENTAL MONITORS
HAZ-SCANNER Wireless Environmental Perimeter Air StationThe portable HAZ-SCANNER Wireless Environmental Perimeter Air Station (EPAS) is easily deployed as an ambient air quality monitor to scan, measure, and document critical EPA criteria pollutants including nitrogen dioxide, carbon monoxide, sulfur dioxide, ozone, carbon dioxide, particulates, VOCs, and more. The EPAS provides direct readings in real time with datalogging capabilities. The graph and reporting software are compatible with PC and Mac.
Features:• Direct Reading• Build your own station with up to 14 simultaneous air measurements including U.S. EPA criteria
air pollutants • Standard configuration measures 5 parameters including PM10 or TSP particulates, NO2, CO,
temperature, and relative humidity • Add one or all optional plug and play sensors and/or EPAS-specific meters (up to 9). Choose
from additional sensors for toxic gas (including hydrocarbons, VOCs, and methane) and biological/chemical agents, and EPAS-specific meters for solar radiance/UV or IR, barometric pressure, sound/noise, atomic radiation, ELF radiation, rain, and wind speed/direction
• Available analog input port for alternative meter • Interchangeable size-selective impactors are available for PM1.0, PM2.5, or PM4.0 (close
approximation of respirable) • Real-time readings, datalogging capabilities
• Optional wireless data transmission up to 5 miles • Optional ethernet internet connection for 24/7 data reporting
• Easily portable and deployable• Battery operated• Network up to 8 EPAS to one central PC or Mac• Easy-to-use graph and reporting software compatible with PC and Mac
Ordering InformationContact a Concept Controls product specialist to build your custom HAZ-SCANNER Wireless EPAS.
PARAMETER SENSOR MEASUREMENT/CONCENTRATION RANGEParticulates 90° infrared light scattering 0 to 20,000 µg or 0 to 200 mg/m3
VOCs PID (10.6 eV) 0 to 100 ppmToxic Gas: NH3 - Ammonia Gas-sensing semiconductor (GSS) technology 0 to 100 ppmToxic Gas: CO2 - Carbon Dioxide NDIR 0 to 5000 ppmToxic Gas: CO - Carbon Monoxide Electrochemical 0 to 100 ppmToxic Gas: Cl2 - Chlorine Electrochemical 0 to 100 ppmToxic Gas: Hydrocarbon, CH4 - Methane Specific NDIR 0 to 1% vol., 0 to 10,000 ppm, 0 to 20% LELToxic Gas: Non-Methane Hydrocarbons (HC) NDIR Calibrated for 0 to 20% LEL or selected gasToxic Gas: HCN - Hydrogen Cyanide Electrochemical 0 to 100 ppmToxic Gas: H2S - Hydrogen Sulfide Electrochemical 0 to 100 ppmToxic Gas: NO - Nitrogen Oxide Electrochemical 0 to 100 ppmToxic Gas: NO2 - Nitrogen Dioxide Electrochemical 0 to 5000 ppb (0 to 5 ppm)Toxic Gas: O2 - Oxygen Electrochemical 0 to 30% vol.Toxic Gas: O3 - Ozone Gas-sensing semiconductor (GSS) technology 0 to 150 ppb (0 to 0.15 ppm), 0 to 500 ppb (o to 0.5 ppm)Toxic Gas: SO2 - Sulfur Dioxide Electrochemical 0 to 5000 ppb (0 to 5 ppm)Rainfall/Precipitation Rain gauge (heated, tipping bucket) 0 to 5 inches dailyTemperature NTC thermister -4° to 140° F (-20° to 60° C)Relative Humidity (RH) Thin-film capacitive 0 to 100% RHSolar Radiance Intensity Photoiodode 1110 watts/square meter (W/m))Sound and Noise Type 2 SLM 30 to 135 decibels (dB)Atomic Radiation Geiger counter 1 to 19,999 counts per min (cpm) or 0.001 to 100 milliRad/hrELF Radiation Sensor with single-axis probe 1 to 200 milligauss (mG)Wind Speed/Direction 3-cut anemometer/continuous rotation potentiometric
wind direction vane0 to 125 mph/5 to 355°
Barometric Pressure Piezo Resistive 28 to 31 in HgDew Point Temperature Software calculation from RH and Temperature -47.2° to 122° F (-44° to 50° C)Wet Bulb Temperature Capsulated thermistor with wick 3.2° to 122° F (-16° to 50° C)
AIR QUALITY
212 www.conceptcontrols.com
Ambient Air Quality Monitor AQM60The AQM 60 monitors fill the gap between full reference monitoring stations and simple diffusion samplers. Typical applications include traffic or roadside monitoring, urban air quality measurement and fenceline monitoring of air pollution sources. The AQM60 utilizes proprietary Analytic GSS Technology to provide high performance within a flexible cost effective package.
The AQM 60 monitors are discreet, highly compact, and deliver precise measurement data for a wide range of ambient pollutants including O3, NO2, CO, SO2, CO2, VOC, plus PM10 and environmental parameters such as temperature, humidity, wind speed and direction, noise and other meteorological sensors. Data is stored internally and is also available in real-time via GSM modem, low power radio, ethernet and other communication options.
Features:• Analytic GSS technology• Multiple gas sensors (up to six)• Temperature and humidity sensors• Particulate monitor (PM2.5 or PM10)• Large internal data storage capacity• Zero and span calibration facility• Remote diagnostics capabilities• Weatherproof and compact enclosures• Thermal management system• Wind speed and direction anemometer• Noise and meteorological sensors• Wireless communication
NEW
Environment Operation Range
10 to 25 C (standard)-20 to 45 C (with heater or cooler)10 to 90 %RH (non condensing)
Communications GSM modem / RF modem / ethernet LAN
Air Velocity, Temperature, Relative Humidity and Pressure
Power AC Adapter AC 100 - 240 V
Battery Li-ion Battery
Dimensions W 7.9 x D 7.9 x H 8.1 inch
Weight 14.2 lbs (6.44 kg)
Accessories Quick-start guide, AC adapter, zero filter, Isokinetic probe with 79 inch (2m) tubing, inlet nozzle, data processing software, memory card, 2 rolls of cleanroom-grade printer paper, 1 x Li-ion battery and calibration certificate
HAZ-DUST IV Particulate MonitorThe HAZ-DUST IV, with new infrared detector, displays immediate breathing zone measurements and comprehensive graph reporting of aerosol and dust for industrial hygiene and environmental air investigations. Operate without a sampling head for total head measurement (NIOSH 0500) or target specific particle fractions by installing an inhalable, thoracic, or respirable sampling head. An in-line 37-mm cassette behind the sensor may be used to collect a concurrent filter sample for gravimetric or chemical analysis.
Features:• Immediate display of
particle concentration in mg/m3
• Interchangeable sampling heads
• Operate without a sampling head for total head measurement (NIOSH 0500)
• Internal adjustable sample pump — 1.0 to 3.3 L/min• In-line cassette directly behind sensor for concurrent filter
sampling• Audible alarm with adjustable threshold• Worker comfort• DustComm Pro Software for downloading, basic trend
analysis, and comprehensive graphical reporting• Run time over 8 hours with rechargeable NiMH battery
Ordering InformationDescription Cat. No.HAZ-DUST IV Monitor includes monitor, thoracic head, in-line filter cassette, carry case, computer cable, battery charger, HAZ-DUST Media CD with instruction manual, and DustComm Pro Software 110 - 240 V 770-4004HAZ-DUST IV Monitor Kit includes all items listed above plus GS Cyclone and adapter, IOM and adapter, calibra-tion jar, and standard 110 - 240 V 770-4004KSampling HeadsInhalable Sampling Head and Adapter, IOM Sampler, mounts on HAZ-DUST IV sensor
770-115A
Thoracic Sampling Head, mounts on inlet or HAZ-DUST IV sensor
770-4107
Respirable Sampling Head, GS-3 Cyclone, mounts on HAZ-DUST IV sensor
225-103
Adapter for Respirable Sampling Head, required when using GS-3 Cyclone
770-313
AccessoriesCalibration Standard for Monitor, for verifying span and optical sensor performance
770-140
Calibration Jar, for calibrating and setting pump flow when using respirable sampling head
225-112
Zeroing Accessory, for clean-air zeroing of sensor when using inhalable sampling head
770-4202A
Zeroing Filter, for use with respirable and thoracic sam-pling heads
770-4102
Requires calibration with equipment sold separately, see accessories
HAZ-DUST Real-Time Particulate Monitor
At the touch of a button, the HAZ-DUST real-time particulate monitor provides accurate and instantaneous data on airborne particle concentration in accordance with NIOSH Method 0600. Designed for industrial hygiene, indoor air quality, and hazardous materials investigations, HAZ-DUST saves money by eliminating repetitious and costly gravimetric air sampling and analysis.
Features:• Easy operation and instantaneous readings in mg/m3 • Selectable dual measuring range feature
• Particulate concentrations between 0.01 and 20 mg/m3 and from 0.1 to 200 mg/m3
• Easy-to-read digital display • Highly sensitive - measurements down to 0.01 mg/m3 • Rechargeable 8 hr battery life & low battery indicator• Unique design provides protection from RFI/EMI • Lightweight, rugged, and portable • Optional tripod mounting • Optional datalogger w/ user-selectable alarm threshold • Easy-to-use DustComm Pro Software available with
datalogger for downloading, time vs concentration profiling, and comprehensive graphical reporting
readingCalibration: SAE fine test dust compared with NIOSH
0600Particle size range: 0.1 to 50 µmPrecision: ± 0.02 mg/m3Accuracy: ± 10% to NIOSH 0600Power: NiMH rechargeable batteryOperating time: > 8 hrsCharging time: 10 to 12 hrsHumidity: 95% non-condensingDimensions: 9 x 2.75 x 1.5 in
(22.9 x 7.0 x 3.8 cm)Weight: 1.10 lbs (0.5 kg)Optional datalogger: Two-key programmable operation. Real-
time clock, display, and user-selectable alarm threshold. Includes software for statistics, graphs, and reports. PC-compatible.
Recording time: 1 sec to 15 moSampling rate: 1 sec, 10 sec, 1 min, 10 min, and 30 min
averagingSignal input: 0 to 2 voltOutput: RS-232C (9600 baud rate)
PARTICLE & DUST MONITORS
AIR QUALITY
216 www.conceptcontrols.com
EPAM 5000The portable HAZ-DUST EPAM-5000 particulate monitor is ideal for ambient, environmental, and indoor air quality investigations. The highly sensitive EPAM-5000 uses light scattering to measure particle concentration and provide real-time determinations and data recordings of airborne particle concentration in mg/m3. Interchangeable size-selective impactors allow PM10, PM2.5, PM1.0, or TSP monitoring. The unique aerodynamic particle sizing and optional 47-mm in-line filter holder loaded with appropriate filter can provide concurrent gravimetric sampling. Download and store sampling data on a PC for analysis and reporting using included DustComm Pro Software.
Features:• Immediate display and data storage of lung damaging
aerosols• Provides both real-time and filter gravimetric data• Unique aerodynamic particle sizing real-time sensor
and in-line 47mm filter cassette which allows concurrent gravimetric samplings
• High correlation to EPMA PM-10 methods and TEOM• Added value survey sampler for saturation monitoring
studies• Easy to use Data Analysis Software• Easy to clean optical sensor with self-purging capabilities• LPKM flow compensated sampling pump• True 24-hour battery capacity or continuous A/C power
operation• Audible Alarm Siren• Optional accessories such as: Solar Power Panel, strobe
light, and inlet heater
EPAM 7500The HAZ-DUST EPAM-7500 portable monitor and air station gives real-time measurements of particulate matter, temperature, and relative humidity in ambient and indoor air. Interchangeable size-selective sampling heads allow PM10, PM2.5, PM1.0, respirable, or TSP monitoring. Optional accessories for measuring wind speed and direction are available. A filter holder positioned directly behind the optical sensor provides concurrent gravimetric sampling for cross calibration of optical sensor, further particulate speciation, and determination of metal and carbon content.
Features:• Immediate display and data storage of lung damaging
aerosols• Provides both real-time and filter gravimetric data.• Unique aerodynamic particle sizing real-time sensor
and in line 47mm filter cassette which allows concurrent gravimetric samplings
• High correlation to EPMA PM-10 methods and TEOM*.• Added value survey sampler for saturation monitoring
studies• Easy to use Data Analysis Software• Easy to clean optical sensor with self-purging capabilities.• LPM flow compensated sampling pump• True 24-hour battery capacity or continuous A/C power
operation• Audible alarm siren• Graphical colour display• USB, ethernet, removable data card and serial DB9
connections• Wind and 1 other optional sensor• Optional accessories such as: Solar Power Panel, strobe
light, and inlet heater
Features:• Particle size range: 0.1 to 10µm• Measuring range: 0.001 to 10 mg/m3• Data logging up to 100,000 measurements• USB interface for data transfer• Compact and light weight unit• More than 24 hours run time with Li-ion battery• Capable of analog and digital output• Useful tripod mount• Rubber protector and Shoulder strap included
Digital Dust Monitor 3443 Measuring Method Light Scattering MethodLight Source Laser diodeMeasuring Object Airborne Particle Matter < 10 µmMeasuring Range 0.001 to 10.0 mg/m3Accuracy +/- 10% of readingData Logging 100,000 data and time
stamped measurementsOutput Digital USB
Analog O to 1 V, Pulse, AlarmPower Supply 6 AA batteries or AC adapterDimensions W 6.4” x H 4.3” x D 2.4” (162 x
109 x 60mm)Weight 2.9 lbs. (1.3 kg)
217www.conceptcontrols.com
PARTICLE & DUST MONITORS
HAZ-DUST VDM-7500Digitally record workplace dust exposure with the HAZ-DUST VDM-7500 wireless video dust monitoring system. The VDM-7500 measures levels of lung damaging particles while simultaneously overlaying dust concentration information onto video images. Easily clip the lightweight monitor to a worker’s belt and the sensor in the breathing zone. Through wireless communication, all data is displayed in real time on the PC. Record and obtain specific events that are clearly linked to worker exposure to airborne contaminants. View, record, and store streaming video, data points, and graphical profiles of dust concentrations on a PC with powerful DustComm Pro Software. Only the VDM-7500 provides you with the integration of video and particulate dust monitoring technology for a more dynamic assessment of air contamination and worker exposure — the components necessary for documentation and control.
Features:• All-in-one system• Digital and wireless for unattended monitoring• Simultaneous real-time workplace video display,
dust readings, and gravimetric collection for any type of aerosol
• Record-to-disk feature• True breathing zone measurements of inhalable, thoracic,
or respirable particulate• Compact and rapidly deployed
Ordering InformationDescription Cat. No.VDM-7500 Wireless Video Dust Monitoring System includes wireless particulate monitor†, wireless video camera, customized portable PC with radio receiver, and all software and hardware setup packaged in a rolling carry case with handle 110 - 240 V 770-7500Accessories*Adapter for GS-3 Respirable Cyclone, required when using GS-3 Cyclone
770-313
Inhalable Sampling Head and Adapter, IOM Sampler, mounts on monitor sensor
770-115A
Calibration Standard for monitor, for verifying span and optical sensor performance
770-140
Replacement Battery Pack, NiMH 770-4105 Requires calibration with equipment sold separately, see accessories * Cleaning Kit accessory available; contact SKC† Use the VDM-7500 only with the HAZ-DUST Monitor included with the system.
Piezobalace Dust Monitor 3521 / 3522Features:
• Data logging ability allows user to log 500 samples
• Simple cleaning mechanism for easy maintenance
• RS232C port available as standard
• Back-lit display• Data can be reviewed on-screen, printed or downloaded to
a computer• Software included for easy data download and processing• Easy operation requires no special training
PrincipleAs an air sample enters the system, it travels through the impactor, which captures and removes larger particulates from the sample. Smaller particulates become electrically charged and deposited on the piezo-crystal. The total mass of the deposited particulates affects the piezo-crystal’s frequency. Since the change in frequency is proportional to the mass of the particulates, the actual weight of the particulates is obtained.
Specifications:
Model 3521 3522Measuring Object Airborne Particle
Matter < 10 µmAirborne Particle Matter < 2.5 µm
Impactor 10 µm, 4 µm 2.5 µm
Measuring Range 0.01 to 10 mg/m3
Sampling Flow Rate
1L/min
Accuracy +/- 10% of reading +/- 1 digit (0 to 5 mg/m3)+/- 20% of reading +/- 1 digit (5 to 10 mg/m3)
Data Logging 500 data and time stamped measurements
Digital Output RS-232C
Power Supply AC or Ni-MH battery
Dimensions H7.0” x D5.9” x W2.7” (180 x 150 x 65mm)
Weight (incl. batteries)
4.4 lbs. (2 kg)
AIR QUALITY
218 www.conceptcontrols.com
Dust Sentry NEW
PAMS is an electrical mobility size spectrometer designed for portable, mobile, or handheld aerosol sampling applications. It provides the number-weighted diameter distribution of aerosols over the entire submicrometre range (10 to 863nm) in one scan. The unit uses a nonradioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations. Its bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometre range.
Features:• Electrical mobility size spectrometer designed for portable,
mobile, or handheld aerosol sampling applications• Provides number-weighted diameter distribution of
aerosols over the entire submicrometre range (10 to 863nm) in one scan
• Uses a non-radioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations
• Bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometre range
• Can be used in two modes: Single diameter count mode: to get a total count within a narrow size range, or Size distribution mode: to get an automated size distribution measurement over desired size range or size resolution
• Stand-alone, battery-operated instrument; no external computer needed
Scan Time 0.2LPM: 42 sec to minutes for one scan0.4LPM: 81 sec to minutes for one scan
Concentration Range 0 to 100,000 particles /cm3
Flow Rate Inlet: 0.7 LPMSample: 0.05 LPM
Bipolar Charger Dual corona charger at 5 μA
Condensing Fluid Isopropyl alcohol
Display Colour touchscreen
Dimensions (WHD) 9.1 x 9.1 x 5.9 inch (23 cm x 23 cm x 15 cm)
Weight 9.9 lbs (4.5 kg )
Portable Aerosol Mobility Spectrometer (PAMS)
NEW
The Dust Sentry provides real time, continuous particle measurement of TSP, PM10, PM2.5 or PM1 with datalogging and alarm relay outputs. Numerous integrated options including SMS and/or email notifications, weather sensors, noise and mounting equipment make the Dust Sentry a flexible base system suitable for a wide range of applications.
Features:• Real time particle monitoring,
measures and reports data in 1 minute intervals
• Accurately measures TSP, PM10, PM2.5 or PM1• On board data storage for up to 15 years of data• Web-based and GSM data retrieval and alerts• Gravimetric filter• Option to integrate weather, wind, temp/RH sensors, and
sirens• Tough weatherproof enclosure with solar shielding for hot
climates• Quick installation and relocatable
Specifications:
Model # DS 10 DS 25 DS 1Measurement technology
Near forward light scattering nephelometry
Range 0-2000µg/m3
Accuracy +/-(2 ug/m3 +5% of reading)
Cut point PM 10 PM 2.5 PM 1
Sample flowrate
2.0 LPM
Inlet Heated
Alarm Relay and SMS (optional)
Datalogging 2GB SD card (>15 years data storage)
Reference filter 25mm GF filter
Software Datalogging and configuration software included
Outputs RS232 & cellular IP Gateway
Mounting Pole and wall mounting
Wireless communication options
Low power RF modem
Meteorological sensor options
Temperature & RH sensor, Gill WindSonic, Vaisala WXT520
Environmental operating range
-10°C to +45°C; 10 to 95% RH (NC)
Power requirements
Mains (100 to 260VAC) or regulated 12VDC (10W)
Enclosure Lockable & weatherproof GRP cabinet IP65; 685 x 350 x 300mm (including solar shield armour &