LabVolt Series Datasheet Air Pressure/Flow Process Learning Systems 3533-00 * The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice. Festo Didactic en 120 V - 60 Hz 10/2021
70
Embed
Air Pressure/Flow Process Learning Systems 3533-00
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
LabVolt Series
Datasheet
Air Pressure/Flow Process Learning Systems3533-00
* The product images shown in this document are for illustration purposes; actual products may vary. Please refer to the Specifications section of each product/item for all details. Festo Didactic reserves the right to change product images and specifications at any time without notice.
Festo Didactic
en 120 V - 60 Hz
10/2021
Air Pressure/Flow Process Learning Systems, LabVolt Series
Smart Devices: HART® and FOUNDATION™ Fieldbus ______________________________________________________ 5
Troubleshooting ____________________________________________________________________________________ 5Air Requirements ___________________________________________________________________________________ 6Topic Coverage _____________________________________________________________________________________ 7Features & Benefits _________________________________________________________________________________ 7List of Available Training Systems______________________________________________________________________ 8Additional Equipment Required to Perform the Exercises___________________________________________________ 8Optional Equipment _________________________________________________________________________________ 8Optional Manual(s) _________________________________________________________________________________ 9Available Training Systems __________________________________________________________________________ 10Equipment Description _____________________________________________________________________________ 23Optional Equipment Description______________________________________________________________________ 43
General DescriptionThe Air Pressure/Flow Process Training Learning , Series 3533, introduce students to process instruments and control performed on air processes. The Learning systems are part of the Instrumentation and Process Control program, which uses modern equipment and a complete curriculum to help students assimilate the theoretical and practical knowledge that is mandatory to work in the process control industry.
The modularity of the systems allows instructors to select only the specific equipment necessary to attain the training objectives, without unrequired equipment. Several configurations are available for a single workstation. Adding optional equipment can increase the number of these configurations.
The Air Pressure/Flow Process Training Systems feature a workstation on which the equipment required for pressure and flow processes can be installed along with the electrical and pneumatic panels. A controller from Series 3539 is required to complete the systems and is part of the pedagogical curriculum. The systems are completed by a wide choice of optional equipment.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Process & Instrumentation Workstation (Air)The Process & Instrumentation Workstation (Air) contains all the equipment required to perform the experiments with compressed air. It is designed to house the Electrical Unit and the Pneumatic Unit as well as other devices such as controllers, PLCs, a Color Paperless Recorder, and a Touch Screen Graphic Terminal The workstation also supports the different air tanks, valves, and instruments used in the experiments. To have a fully functional system, a controller, Series 3539, is required.
To configure the system for hands-on training, the students have to install the appropriate instruments as described in the student manuals. The student manuals cover both the theory and practice of measurement, control, and troubleshooting of pressure and flow air processes.
The Electrical Unit provides power for the whole system, includes a lockable power switch, and a 24 V dc power supply. The design of the Electrical Unit allows cutoff of both the electric and pneumatic power using either an emergency button or the lockable power switch. The teaching material includes a complete lockout/tagout procedure explaining how to lock the power switch. This procedure is similar to the procedure used in industry to lock and unlock electrical equipment.
The workstation also features a storage cabinet with lockable doors and a retractable shelf.
Process & Instrumentation Workstation (shown with optional equipment)
The dimensions of the Workstation (excluding any device installed on it) are: 680 x 1180 x 1890 mm (26.8 x 46.5 x 74.4 in).
•••••
Pressure and Flow – Compressed AirMeasurement and control experiments related to pressure and flow of compressed air can be done with the following devices:
Air Tanks (2 sizes available)Air RotameterOrifice Plate for airSolenoid Valve for airPneumatic Control Valve
Air Pressure/Flow Process Learning Systems, LabVolt Series
Optional ValvesVarious pneumatic control valves are available to upgrade the Learning systems. The valves are provided with a current-to-pressure converter (if required). The available valves are listed below:
Pneumatic Control Valve with different Digital Positioners (HART or FOUNDATION Fieldbus)Pneumatic Control Valve (with Positioner)Solenoid Valve for air
••
ControllersA wide selection of controller are also available:
Industrial PID Controllers (Ethernet or Modbus)Programmable Logic Controllers (with Ethernet communications, Analog I/O, programming software, and Communication Cable)
SCADA / DCS SoftwareTwo SCADA software programs are available for the system: Wonderware Development Studio (including InTouch) and FactoryTalk View Studio (from Rockwell Software). Both software programs come with an interface specially designed for the Instrumentation and Process Control Training Systems. An OPC server for the Foxboro controller is also available.
Calibration InstrumentationAn accurate calibration device is an essential addition to the system. It allows calibration and maintenance of the transmitters, current to pressure converter, gauges, and control valves. Four different calibration packages are available. A basic version makes it possible to perform the required calibration and a second version includes more advanced equipment. The two other calibration kits are each designed to act as configurator and sophisticated tools to calibrate the smart devices.
••
Additional EquipmentOther devices are also available to enhance the system. These devices allow the students to explore more technologies and communication protocols used in the industry. Among the optional devices available are:
a Signal TowerTouch Screen Graphic Terminal (available in two sizes)
Air Pressure/Flow Process Learning Systems, LabVolt Series
Smart Devices: HART® and FOUNDATION™ FieldbusA few components of the Air Pressure/Flow Process Learning Systems feature a transmitter which is able to communicate via one of two communication protocols: HART or FOUNDATION Fieldbus.
The HART protocol enables communication between devices by superimposing digital signals on top of the existing 4-20 mA outputs. The FOUNDATION Fieldbus protocol is like a Local Area Network (LAN) for smart devices.
Most of these devices can be configured manually via their alphanumeric display and/or push-buttons, but it is much quicker and more efficient to use a communication link to configure them remotely from a computer. The HART apparatuses can be connected to a computer using the HART Software Configurator (Model 46982-0 or -B). FOUNDATION Fieldbus devices can be configured from a computer with the FOUNDATION Fieldbus Software Configurator (Model 46982-A or -B). Calibration kits are available for each of the two communication protocols.
A Software Configurator compatible with the selected communication protocol is strongly suggested.
••
•
TroubleshootingTroubleshooting of industrial process equipment is an integral part of the learning process. This is why the Air Pressure/Flow Process Training Systems feature many tools to help instructors devise troubleshooting exercises for the students. Faults can be inserted in most devices: Controllers, PLCs, Valves, Transmitters, etc.
There are three different methods to insert faults:
Local fault insertion is done by accessing the fault panel on a particular device to activate faults as required.Remote calibration fault insertion is performed by changing the calibration parameters of a device from the instructor's computer over either the HART or the FOUNDATION Fieldbus communication protocol (requires the appropriate modules).Remote fault insertion is achieved by remotely modifying the state of I/O relays on a PLC from a computer or from a touch screen terminal.
Details of a setup on the Process & Instrumentation Workstation (shown with optional equipment).
Air Pressure/Flow Process Learning Systems, LabVolt Series
Content dependency structure of the manuals for the training system.
Air RequirementsThe Air Pressure/Flow Process Learning System requires a reliable source of compressed air from a central air supply or portable unit able to deliver air at a minimal flow of 110 L/min (4 CFM), with a pressure of 620 kPa (90 PSI).
Compressed air units are also available. The Air Compressor, Model 6410-B, is a silent portable unit able to supply air to a single station and is well suited to the systems.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Air pressure and flow (basics, measurement, process control)
Features & Benefits
Complete training program that helps students to assimilate theoretical and practical knowledgeComprehensive curriculum
1 Required if no source of compressed air is available in the lab. The Air Compressor, Model 6410-C is also available.2 Required if no source of compressed air is available in the lab. The Air Compressor, Model 6410-B is also available.3 Necessary if the selected controller is a Programmable Logic Controller. Refer to the Computer Requirements in the System Specifications section of this datasheet if the computer is to be provided by the end-user.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Air Pressure/Flow Process Training System (Allen-Bradley) – HART588505 (3533-00)
The Air Pressure/Flow Process Training System (Allen-Bradley) – HART introduces students to process instruments and control performed on air processes. The use of modern equipment coupled with a complete training program helps students to assimilate the theoretical and practical knowledge that is mandatory to work in the process control industry.
The modularity of the system allows instructors to select only the specific equipment necessary to attain the training objectives, without unnecessary equipment. Several configurations are available for a single workstation. Adding optional equipment can increase the number of these configurations.
The Air Pressure/Flow Process Training System (Allen-Bradley) – HART features a workstation on which the equipment required for pressure and flow processes can be installed along with the electrical and pneumatic panels. A controller from Series 3539 is required to complete the system and is part of the pedagogical curriculum. The system comes with an Allen-Bradley unmanaged switch and it is completed by a wide choice of optional equipment.
List of Equipment
Qty DescriptionModel number
1 Emergency Switch Station ________________________________________________________ 582352 (5926-A0)1 Digital Pressure Gauge (High Range) _______________________________________________ 582387 (46761-B0)1 Instrumentation Workstation (Without Heating/Cooling Unit) __________________________ 582393 (46900-F0)1 Air Tank (Large) ________________________________________________________________ 588312 (46906-00)1 Air Tank (Small) ________________________________________________________________ 588313 (46906-A0)1 Muffler Assembly ______________________________________________________________ 588314 (46907-00)1 Orifice Plate (Air- High Flow) ______________________________________________________ 582404 (46914-00)1 Rotameter (Air) ________________________________________________________________ 582405 (46915-00)1 Differential-Pressure Transmitter (HART, Low Range) __________________________________ 582410 (46921-00)1 Solenoid Valve (Air) _____________________________________________________________ 582427 (46951-A0)1 Pneumatic Control Valve (Air) _____________________________________________________ 582428 (46953-00)1 Electrical Unit __________________________________________________________________ 592680 (46970-10)1 Pneumatic Unit ________________________________________________________________ 582433 (46971-A0)1 Color Paperless Recorder ________________________________________________________ 595185 (46972-A0)1 Instrumentation Mounting Pipe ___________________________________________________ 582444 (46990-00)1 Piping and Accessories (Air, Allen-Bradley) __________________________________________ 588433 (46993-H0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
Process Control (Workbook) (585121 (85989-00))1-1 Determining the Dynamic Characteristics of an Air Process2-1 Tuning and Control of a Pressure Loop2-2 Tuning and Control of a Flow Loop3-1 Guided Process Control Troubleshooting
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
System SpecificationsParameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1900 x 1200 x 1200 mm (74.8 x 47.2 x 47.2 in)
Net Weight TBE
Air Pressure/Flow Process Training System – FOUNDATION Fieldbus588509 (3533-10)
The Air Pressure/Flow Process Training System – FOUNDATION Fieldbus includes two differential-pressure transmitters:
FOUNDATION Fieldbus High RangeFOUNDATION Fieldbus Low Range
Measurement and control experiments related to pressure and flow of compressed air can be performed using only the equipment provided with the training system. However, a PLC controller of Series 3539 and the FOUNDATION Fieldbus PLC Add-On, Model 3539-9, are require to implement all system functionalities.
DescriptionManual number
Measurement (Workbook) ___________________________________________________________585119 (85988-00)Measurement (Workbook (Instructor)) _________________________________________________585120 (85988-10)Process Control (Workbook) __________________________________________________________585121 (85989-00)Process Control (Workbook (Instructor)) ________________________________________________585122 (85989-10)Control Valves (User Guide) __________________________________________________________585145 (86001-E0)Familiarization with the Training System (User Guide) _____________________________________________ 8089744
Air Pressure/Flow Process Learning Systems, LabVolt Series
Process Control (Workbook) (585121 (85989-00))1-1 Determining the Dynamic Characteristics of an Air Process2-1 Tuning and Control of a Pressure Loop2-2 Tuning and Control of a Flow Loop3-1 Guided Process Control Troubleshooting
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)
DescriptionManual number
Measurement (Workbook) ___________________________________________________________585119 (85988-00)Measurement (Workbook (Instructor)) _________________________________________________585120 (85988-10)Process Control (Workbook) __________________________________________________________585121 (85989-00)Process Control (Workbook (Instructor)) ________________________________________________585122 (85989-10)Control Valves (User Guide) __________________________________________________________585145 (86001-E0)Familiarization with the Training System (User Guide) _____________________________________________ 8089744
Air Pressure/Flow Process Learning Systems, LabVolt Series
6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
System SpecificationsParameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1900 x 1200 x 1200 mm (74.8 x 47.2 x 47.2 in)
Net Weight TBE
Air Pressure/Flow Process Training System (Siemens) – HART589886 (3533-20)
The Air Pressure/Flow Process Training System (Siemens) – HART introduces students to process instruments and control performed on air processes. The use of modern equipment coupled with a complete training program helps students to assimilate the theoretical and practical knowledge that is mandatory to work in the process control industry.
The modularity of the system allows instructors to select only the specific equipment necessary to attain the training objectives, without unnecessary equipment. Several configurations are available for a single workstation. Adding optional equipment can increase the number of these configurations.
The Air Pressure/Flow Process Training System (Siemens) – HART features a workstation on which the equipment required for pressure and flow processes can be installed along with the electrical and pneumatic panels. A controller from Series 3539 is required to complete the system and is part of the pedagogical curriculum. The system comes with an Siemens unmanaged switch and it is completed by a wide choice of optional equipment.
List of Equipment
Qty DescriptionModel number
1 Emergency Switch Station ________________________________________________________ 582352 (5926-A0)1 Digital Pressure Gauge (High Range) _______________________________________________ 582387 (46761-B0)1 Instrumentation Workstation (Without Heating/Cooling Unit) __________________________ 582393 (46900-F0)1 Air Tank (Large) ________________________________________________________________ 588312 (46906-00)1 Air Tank (Small) ________________________________________________________________ 588313 (46906-A0)1 Muffler Assembly ______________________________________________________________ 588314 (46907-00)1 Orifice Plate (Air- High Flow) ______________________________________________________ 582404 (46914-00)1 Rotameter (Air) ________________________________________________________________ 582405 (46915-00)1 Differential-Pressure Transmitter (HART, Low Range) __________________________________ 582410 (46921-00)1 Solenoid Valve (Air) _____________________________________________________________ 582427 (46951-A0)1 Pneumatic Control Valve (Air) _____________________________________________________ 582428 (46953-00)1 Electrical Unit __________________________________________________________________ 592680 (46970-10)1 Pneumatic Unit ________________________________________________________________ 582433 (46971-A0)1 Color Paperless Recorder ________________________________________________________ 595185 (46972-A0)1 Instrumentation Mounting Pipe ___________________________________________________ 582444 (46990-00)1 Piping and Accessories (Air, Siemens) ______________________________________________ 589882 (46993-Q0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
Process Control (Workbook) (585121 (85989-00))1-1 Determining the Dynamic Characteristics of an Air Process2-1 Tuning and Control of a Pressure Loop2-2 Tuning and Control of a Flow Loop3-1 Guided Process Control Troubleshooting
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
The PID Controller (Honeywell) is composed of a Honeywell UDC3500 Dual Loop Controller and a user guide.
The Honeywell controller can implement the different PID procedures and is able to perform cascade control. A wireless infrared communication port enables controller setup from a computer or Pocket PC (neither is included), and an Ethernet communication port allows simple connection to a network. The controller features a fluorescent display with push-buttons, a simple configuration software to setup the controller from a
computer, math and logic packages, and other advanced features like fuzzy logic and auto-tune functions. A total of ten switches is located in a panel behind the module to insert faults in the system for troubleshooting exercises.
DescriptionManual number
Measurement (Workbook) ___________________________________________________________585119 (85988-00)Measurement (Workbook (Instructor)) _________________________________________________585120 (85988-10)Process Control (Workbook) __________________________________________________________585121 (85989-00)Process Control (Workbook (Instructor)) ________________________________________________585122 (85989-10)Control Valves (User Guide) __________________________________________________________585145 (86001-E0)Familiarization with the Training System (User Guide) _____________________________________________ 8089744
Air Pressure/Flow Process Learning Systems, LabVolt Series
This bundle includes a Siemens S7-1500 PLC, a Distributed I/O Module (HART), one copy of STEP 7 Software , one copy of the Process Device Manager Software and a user guide.
List of Equipment
Qty DescriptionModel number
1 Programmable Logic Controller (S7-1516) __________________________________________ 589671 (46962-00)1 Distributed I/O Module (HART) ___________________________________________________ 589674 (46976-00)1 TIA Portal PLC Software (Step 7 Professional) with Process Device Manager (PDM) _________ 589676 (46986-00)
Additional Equipment Required to Perform the Exercises
The RSLogix Micro software is a tool to design and implement ladder programs for the Allen-Bradley MicroLogix™ family of processors (it cannot be used with SLC 500 controllers). It is a
Windows®-based application produced by Rockwell Software that allows PLC programming using a personal computer.
The free-form ladder of RSLogix Micro lets students concentrate on the application logic rather than using the proper syntax when editing programs. Several other features of RSLogix Micro greatly facilitate PLC programming, such as a project verifier, drag-and-drop editing, and search-and-replace functions. The PLC can be programmed via either an RS-232 port or an Ethernet
port on the PLC processor. This software comes with RSLinx™, which provides connectivity between the PLC and the computer.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The RSLogix Micro software is a tool to design and implement ladder programs for the Allen-Bradley MicroLogix™ family of processors (it cannot be used with SLC 500 controllers), such as the Programmable Logic Controller (MicroLogix), Model 46964. It
is a Windows®-based application, produced by Rockwell Software, that allows PLC programming using a personal computer.
The free-form ladder of RSLogix Micro lets students concentrate on the application logic rather than using the proper syntax when editing programs. Several other features of RSLogix Micro greatly facilitate PLC programming, such as a project verifier,
drag-and-drop editing, and search-and-replace functions. The PLC can be programmed via either an RS-232 port or an Ethernet port on the PLC processor. This software comes with RSLinx™, which provides connectivity between the PLC and the computer.
The software is available with either an educational license (Model 3245-A) or as a commercial license (Model 3245-B).
SpecificationsParameter Value
Computer RequirementsA currently available personal computer Pentium type with RS-232 serial port, running under one of the
Microsoft® operating systems, Windows® 2000, Windows® XP, Windows® Vista or Windows® 7, is required.
Communication Cable (Allen-Bradley) 587566 (3246-40)
The communication cable is an RS-232-C serial cable specifically designed to connect a personal computer to an Allen-Bradley programmable logic controller, thus making it possible to program and monitor the PLC.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Emergency Switch Station consists of a mushroom-type push-button that opens its circuit when the button is pressed in order to cut the power to some of the 24 V dc outputs of the electrical unit, the pneumatic unit, and the pump drive.
SpecificationsParameter Value
Physical Characteristics
Dimensions (H x W x D) TBE
Net Weight TBE
Studio 5000 Logix Designer Lite Edition 587890 (5935-00)
Studio 5000 Logix Designer is a Windows-based application, produced by Rockwell Software™, used to build programs for PLCs.
Studio 5000 Logix Designer provides a powerful integrated interface allowing users to easily build programs using four programming languages: relay ladder, structured text, sequential function chart, and function block diagram. The software allows students to concentrate on the logic aspects of PLC programming instead of spending time on complex syntax. It also features drag-and-drop editing, search-and-replace functions, and tools for verifying programs before running them on a PLC. Studio 5000 Logix Designer can be used to program a
PLC via the built-in RS-232 port or via an Ethernet link. The software comes with RSLinx lite which provides the functionality required to support RSLogix and RSNetWorx.
Air Pressure/Flow Process Learning Systems, LabVolt Series
5935-0: Studio 5000 Logix Designer Lite Edition5935-1: Studio 5000 Logix Designer Full Edition5935-A: Studio 5000 Logix Designer Lite Edition (Commercial)5935-B: Studio 5000 Logix Designer Full Edition (Commercial)
SpecificationsParameter Value
Included Software RSLogix 5000 and RSLinx Lite
Available Languages Relay ladder, structured text, sequential function chart, and function block diagram.
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
Windows® 8.
Studio 5000 Logix Designer Full Edition 587895 (5935-10)
Studio 5000 Logix Designer is a Windows-based application, produced by Rockwell Software™, used to build programs for PLCs.
Studio 5000 Logix Designer provides a powerful integrated interface allowing users to easily build programs using four programming languages: relay ladder, structured text, sequential function chart, and function block diagram. The software allows students to concentrate on the logic aspects of PLC programming instead of spending time on complex syntax. It also features drag-and-drop editing, search-and-replace functions, and tools for verifying programs before running them on a PLC. Studio 5000 Logix Designer can be used to program a
PLC via the built-in RS-232 port or via an Ethernet link. The software comes with RSLinx lite which provides the functionality required to support RSLogix and RSNetWorx.
The following versions are available:
5935-0: Studio 5000 Logix Designer Lite Edition5935-1: Studio 5000 Logix Designer Full Edition5935-A: Studio 5000 Logix Designer Lite Edition (Commercial)5935-B: Studio 5000 Logix Designer Full Edition (Commercial)
SpecificationsParameter Value
Included Software RSLogix 5000 and RSLinx Lite
Available Languages Relay Ladder, structured text, sequential function chart, and function block diagram.
Computer Requirements
Pentium IV 2.8 GHz, 1 GB of RAM, at least 16 GB of free hard disk space, and a 1024 x 768 True Color graphics device. Recommended: Intel i5 2.4 GHz processor, 8 GB of RAM, 20 GB of free hard disk space, and DirectX 9 graphics device with WDDM 1.0 or higher. Compatible operating systems: Windows XP Professional with SP3, Windows 7 Professional (64-bit) with SP1 or Home Premium (64 or 32-bit) with SP1.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Studio 5000 Logix Designer Lite Edition (Commercial) 587892 (5935-A0)
Studio 5000 Logix Designer is a Windows-based application, produced by Rockwell Software™, used to build programs for PLCs.
Studio 5000 Logix Designer provides a powerful integrated interface allowing users to easily build programs using four programming languages: relay ladder, structured text, sequential function chart, and function block diagram. The software allows students to concentrate on the logic aspects of PLC programming instead of spending time on complex syntax. It also features drag-and-drop editing, search-and-replace functions, and tools for verifying programs before running them on a PLC. Studio 5000 Logix Designer can be used to program a
PLC via the built-in RS-232 port or via an Ethernet link. The software comes with RSLinx lite which provides the functionality required to support RSLogix and RSNetWorx.
The following versions are available:
5935-0: Studio 5000 Logix Designer Lite Edition5935-1: Studio 5000 Logix Designer Full Edition5935-A: Studio 5000 Logix Designer Lite Edition (Commercial)5935-B: Studio 5000 Logix Designer Full Edition (Commercial)
SpecificationsParameter Value
Included Software RSLogix 5000 and RSLinx Lite
Available Languages Relay ladder, structured text, sequential function chart, and function block diagram.
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
Windows® 8.
Studio 5000 Logix Designer Full Edition (Commercial) 587894 (5935-B0)
Studio 5000 Logix Designer is a Windows-based application, produced by Rockwell Software™, used to build programs for PLCs.
Studio 5000 Logix Designer provides a powerful integrated interface allowing users to easily build programs using four programming languages: relay ladder, structured text, sequential function chart, and function block diagram. The software allows students to concentrate on the logic aspects of PLC programming instead of spending time on complex syntax. It also features drag-and-drop editing, search-and-replace functions, and tools for verifying programs before running them on a PLC. Studio 5000 Logix Designer can be used to program a
PLC via the built-in RS-232 port or via an Ethernet link. The software comes with RSLinx lite which provides the functionality required to support RSLogix and RSNetWorx.
Air Pressure/Flow Process Learning Systems, LabVolt Series
5935-0: Studio 5000 Logix Designer Lite Edition5935-1: Studio 5000 Logix Designer Full Edition5935-A: Studio 5000 Logix Designer Lite Edition (Commercial)5935-B: Studio 5000 Logix Designer Full Edition (Commercial)
SpecificationsParameter Value
Included Software RSLogix 5000 and RSLinx Lite
Available Languages Relay Ladder, structured text, sequential function chart, and function block diagram.
Computer Requirements
Pentium IV 2.8 GHz, 1 GB of RAM, at least 16 GB of free hard disk space, and a 1024 x 768 True Color graphics device. Recommended: Intel i5 2.4 GHz processor, 8 GB of RAM, 20 GB of free hard disk space, and DirectX 9 graphics device with WDDM 1.0 or higher. Compatible operating systems: Windows XP Professional with SP3, Windows 7 Professional (64-bit) with SP1 or Home Premium (64 or 32-bit) with SP1.
I/O Interface with LVProSim 763509 (9065-B0)
The I/O Interface is a module used to interface with a computer for data acquisition and PID control of a real process. The I/O Interface provides interconnection between the process devices and the computer. It performs analog signal and digital signal conversions and sends the information to LVProSim, a process control software included with the interface.
The I/O Interface has four 4-20 mA analog inputs, two 4-20 mA analog outputs, four 24 V digital inputs, and two 24 V digital outputs. It connects to a computer through a USB cable and must be powered using a 24 V dc power supply.
The I/O Interface requires LVProSim, a process control software specially designed to connect to the interface and collect data at
a fast sampling rate (100 ms). LVProSim has two main features: it can operate as a process controller and a generic process simulator. LVProSim's modern web interface makes it easy to use, helping students focus on learning process control.
When used as a controller, LVProSim monitors data from the I/O Interface and applies a standard PID algorithm to determine the appropriate response. LVProSim can either control two processes simultaneously or use its two controllers in cascade mode. LVProSim also offers a set of mathematical functions to treat inputs and outputs signals.
The simulation mode allows students to model first-order or second-order processes. This mode encourages students to explore the various characteristics of a process such as its time constants, gain, and dead time. Once a generic process simulation is running, students can connect the simulated process to a controller and test different control schemes. Contrary to the data acquisition mode, the simulation mode does not require the I/O Interface. Therefore, students can experiment with the software on their own computer.
LVProSim is free to use and can be downloaded without charge. See the "Downloads" section below!
Note that, although the I/O interface is designed to be used with LVProSim, its data acquisition interface is
compatible with Linux®, MATLAB®, and NI LabVIEW™. Raw data can be acquired using these software/platform, given the appropriate drivers are installed.
Air Pressure/Flow Process Learning Systems, LabVolt Series
LVProSim uses a non-interacting ideal algorithm to control processes. Two controllers are available. They can be used to control two independent processes or they can be coupled via a dynamic set point for cascade control. The sampling interval and the controller action (director or reverse) are user selectable. A square-root extracting function permits linearization of measured signals and other mathematical functions are available as well.
The proportional (P), integral (I), and derivative (D) contributions on the final controller output can be displayed independently on the trend recorder. Meters can be added to the interface to display monitored variables in real time.
Trend Recorder
The LVProSim trend recorder can be used to plot different variables such as the set points, output signals, signals from the proportional, integral, and derivative contributions, measured and controlled variables, the function generator output signal, etc. A pause button can be used to stop the recorder at any time. The trend recorder can be scrolled backward and forward in time, with automatic time tracking during scrolling. Data can be exported to CSV format to be later imported into a spreadsheet software for detailed analysis and accurate measurement of the process characteristics.
Function Generator
The function generator can produce a sine, square, triangle, or step signal. The signal from the function generator can be used as the controller set point or to perform manual control of a process device. When using LVProSim in the simulation mode, the generator signal can be used as the controller set point, the disturbance signal, or
the controller output signal.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Computer RequirementsA currently available personal computer with USB 2.0 or 3.0 port, running under one of the following operating
systems: Windows® 7, Windows® 8 or Windows® 10 .
Physical Characteristics
Dimensions (H x W x D) 55 x 120 x 172 mm (2.2 x 4.7 x 6.8 in)
Net Weight 1 kg (2.2 lb)
••••
Data Acquisition
Through continuous acquisition of process data via the I/O Interface, LVProSim can:
achieve digital PID control of the processbe used as the primary and secondary controller of a cascade control loopbe used as a process simulatorbe used as a general purpose data acquisition system
Generic Process Simulator
The generic process simulator provides simplified simulation to introduce basic concepts of process control. The simulator can be configured as first or second order process, with or without dead time. The disturbance can be configured as first order. The process and disturbance have variable gains.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Digital Pressure Gauge (High Range) 582387 (46761-B0)
The Digital Pressure Gauge provides a direct reading of the pressure in one of many convenient measurement units. It features two interconnected pressure ports, an LCD display, and is equipped with a mounting bracket for simple installation on the workstation. The pressure gauge is available in two versions with different operating ranges:
The Instrumentation Workstation is designed to house the Electrical Unit, the Pneumatic Unit, as well as all other electrical components that are not measuring instruments. Devices such as controllers, PLCs, Color Paperless Recorders, and Touch Screen Graphic Terminals must be installed on the Instrumentation Workstation. This prevents the equipment from coming in contact with water.
The Instrumentation Workstation, Model 46900-F, does not include a Heating/Cooling Unit.
Like the Process Workstation, the Instrumentation Workstation is a double-sided mobile workstation. Two groups of students can work on the system at the same time, one group on each side.
SpecificationsParameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) TBE
Net Weight TBE
Air Pressure/Flow Process Learning Systems, LabVolt Series
This Air Tank is a robust ASME-compliant pressure vessel designed to contain pressurized air. It features two pressure ports equipped with a quick-connect fitting (1/4 inch) and a graduated hand-operated valve.
SpecificationsParameter Value
Capacity 7.6 L (2 gal)
Maximum Pressure 10.34 bar (150 psi)
Air Tank (Small) 588313 (46906-A0)
This Air Tank is a robust pressure vessel designed to contain pressurized air. It features two pressure ports each equipped with a quick-connect fitting (1/4 inch) and a graduated hand-operated valve. The tank is coated to resist corrosion and is tested to SAE J10 compliance.
SpecificationsParameter Value
Capacity 0.95 L (1/4 gal)
Maximum Pressure 10.34 bar (150 psi)
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Muffler Assembly is composed of two air inlet ports connected to a muffler to reduce exhaust noise. A graduated hand valve for each air inlet restricts the access to the muffler while a third one is used to link the two input lines.
Orifice Plate (Air- High Flow) 582404 (46914-00)
The Orifice Plate (Air - High Fow) is a flow measurement device designed for air applications. It uses the Venturi effect to produce a pressure drop from which the flow rate can be inferred. This primary element consists of an orifice precisely machined in a brass tube. The Orifice Plate requires the use of a differential-pressure transmitter to directly convert the pressure drop into a usable flow rate value.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Rotameter is a variable area flowmeter specifically calibrated to measure the air flow in a compressed air setup. It provides a direct visual reading of the flow by simply observing the position of a float inside the transparent graduated tube.
Differential-Pressure Transmitter (FOUNDATION Fieldbus, High Range) 582409 (46920-A0)
A differential pressure transmitter is an instrument that senses a pressure difference between two points and converts the pressure to a standardized electronic signal which can be sent to a control element. The transmitter can be configured so that its signal is either proportional to a pressure differential, a flow rate, or a level.
The High Range version of the differential pressure transmitter is designed to operate in a range going from a difference of 0 kPa (0 psi) to an absolute difference of 1.6 MPa (240 psi).
This Differential-Pressure Transmitter includes a transmitter which is compatible with the Foundation Fieldbus communication protocol.
A differential pressure transmitter is an instrument that senses a pressure difference between two points and converts the pressure to a standardized electronic signal which can be sent to a control element. The transmitter can be configured so that its signal is either proportional to a pressure differential, a flow rate, or a level.
The Low Range version of the differential pressure transmitter is designed to operate in a range going from a difference of 0 kPa (0 psi) to an absolute difference of 50 kPa (7.3 psi).
This Differential-Pressure Transmitter includes a transmitter which is compatible with the HART communication protocol.
Available Differential-Pressure Transmitters:
46920-0 Differential-Pressure Transmitter (HART, High Range)46920-A Differential-Pressure Transmitter (Fieldbus, High Range)
A differential pressure transmitter is an instrument that senses a pressure difference between two points and converts the pressure to a standardized electronic signal which can be sent to a control element. The transmitter can be configured so that its signal is either proportional to a pressure differential, a flow rate, or a level.
The Low Range version of the differential pressure transmitter is designed to operate in a range going from a difference of 0 kPa (0 psi) to an absolute difference of 50 kPa (7.3 psi).
This Differential-Pressure Transmitter includes a transmitter which is compatible with the Foundation Fieldbus communication protocol.
The Solenoid Valve (Air) is a four-way, two-position, single-solenoid operated, directional control valve. It is made of brass and has 1/4 inch connectors. The valve can be used, among other things, to direct the flow of air and to create perturbations in the system. A 24 V dc signal is used to toggle the position of the solenoid.
Pneumatic Control Valve (Air) 582428 (46953-00)
The Pneumatic Control Valve for Air is a normally closed stainless steel valve with 1/4 inch connectors designed to regulate the flow of air. This compact valve features a rugged construction and good control characteristics over the air flow. The Pneumatic Control Valve (Air) includes a current-to-pressure converter which transforms a 4-20 mA input signal into a pneumatic signal sent to the actuator of the valve.
This control valve is available in different versions which can include a positioner. The various versions are:
46953-00 Pneumatic Control Valve (Air)46953-A0 Pneumatic Control Valve for Air with Digital Positioner (HART) -
DVC 200046953-B0 Pneumatic Control Valve for Air with a Positioner - Fisher 366046953-C0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 620046953-D0 Pneumatic Control Valve for Air with Digital Positioner (FOUNDATION Fieldbus) - DVC 6200
Table of Contents of the Manual(s)
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory
Manual
DescriptionManual number
Control Valves (User Guide) __________________________________________________________585145 (86001-E0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
PID Controller (Honeywell) 588380 (46961-00)
The PID Controller (Honeywell) is composed of a Honeywell UDC3500 Dual Loop Controller. The Honeywell controller can implement the different PID procedures and is able to perform cascade control. A wireless infrared communication port enables controller setup from a computer or Pocket PC (neither is included), and an Ethernet communication port allows simple connection to a network. The controller features a fluorescent display with push-buttons, simple configuration software to setup the controller from a computer, math and logic packages, and other advanced features like fuzzy logic and autotune functions. A total of ten switches is located in a panel behind the module to insert faults in the system for troubleshooting
The Programmable Logic Controller (S7-1516) consists of a controller from the Siemens family. This powerful PLC comes with sixteen 24 V dc inputs, eight 4-20 mA inputs, eight 24 V dc output relays and eight 4-20 mA outputs hardwired to both banana jacks and terminal blocks on the module front panel. Banana jacks provide an easy and fast way to wire a setup, while terminal blocks allow students to wire their setup in a way much closer to what is commonly found in the industry.
The Siemens S7-1516 PLC supports two types of network communication: one PROFIBUS and three PROFINET ports.
The S7-1516 PLC is programmed using Siemens SIMANTIC STEP 7 Pro software in TIA Portal environnement (Model 46986) using any of four languages: Ladder (LAD), Function Block Diagram (FBD), Instruction List (IL). This module has ten switches that the instructor can use to insert faults.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Programmable Logic Controller (AB MicroLogix 1100) 588381 (46964-00)
The AB MicroLogix 1100 PLC is a compact programmable logic controller ideal for small to mid-sized applications. It features ten digital inputs, two analog inputs, six digital outputs, and two analog outputs. Programs for this PLC are written using Rockwell's RSLogix Micro software (Model 3245-A or -B) and can be used to implement a wide variety of control procedures, including PID routines.
It includes an Ethernet communication port, a DF1 Full-Duplex Serial link (RS-232-C) port, an embedded LCD and control keys,
and many more advanced features. Hidden behind the module is a total of eight switches that the instructor can use to insert faults in the system.
Programmable Logic Controller (AB ControlLogix) 589122 (46965-10)
The Programmable Logic Controller (AB ControlLogix) consists of a controller from the Allen-Bradley family. This powerful PLC comes with sixteen 24 V dc inputs, eight 4-20 mA HART inputs, eight 24 V dc output relays and eight 4-20 mA HART outputs hardwired to both banana jacks and terminal blocks on the module front panel. Banana jacks provide an easy and fast way to wire a setup, while terminal blocks allow students to wire their setup in a way much closer to what is commonly found in the industry.
The ControlLogix PLC supports EtherNet/IP. The EtherNet/IP communication ports are located on the PLC processor. A USB port, also located on the PLC processor, can be used to transfer a program into the PLC.
The ControlLogix PLC can be programmed using Rockwell's RSLogix 5000 Full Edition software (Model 5935-1 or -B) in any of four languages: relay ladder, structured text, sequential function chart, and function block diagram. The module has ten switches that the instructor can use to insert faults.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Programmable Logic Controller (AB CompactLogix) 589123 (46966-10)
The AB CompactLogix PLC is a cost-effective controller from the Allen-Bradley family of Logix controllers. This PLC features a L24 CPU and includes sixteen 24 V dc digital inputs and sixteen 24 V dc digital output relays hardwired to both banana jacks and terminal blocks on the module front panel. Banana jacks provide an easy and fast way to wire a setup, while terminal blocks allow students to wire their setup in a way much closer to what is commonly found in the industry. A total of eight 4-20 mA analog inputs and eight 4-20 mA analog outputs are also included.
The CompactLogix PLC supports Ethernet/IP network communication. The two Ethernet/IP ports are located on the front panel to make the cabling more convenient.
The CompactLogix PLC is programmed with Rockwell's RSLogix 5000 Lite Edition software (Model 5935 or -A) using any of four languages: Relay ladder, structured text, sequential function chart, and function block diagram. This module has ten switches that the instructor can use to insert faults.
Electrical Unit 592680 (46970-10)
The Electrical Unit is the source of 24 V dc power for the system. It includes a lockable safety switch, a power transformer from line level to 24 V dc, and all the necessary inputs and outputs in both a banana jack version and in a terminal block version. A fault panel is also included to easily insert a fault during troubleshooting exercises.
Pneumatic Unit 582433 (46971-A0)
The Pneumatic Unit regulates the pressurized air coming from an external compressed air source. It includes an activation switch to quickly turn on or off the air supplied, an adjustable low-range pressure regulator (0 to 200 kPa (0 to 30 psi)) with its output air port, and an adjustable high-range pressure regulator (0 to 700 kPa (0 to 100 psi)) with its output air port. A fault panel is included to insert a fault in the system when performing troubleshooting exercises.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Color Paperless Recorder is a state-of-the-art device designed to acquire, display, record, and archive analog input signals. Four high-speed 4-20 mA inputs with a scan time of 100 ms are available and can be displayed on the thin-film-transistor (TFT) 17.8
cm (7 in) color display. The device can be configured using push-buttons and a shuttle dial, and it can be programmed to activate one of four output relays as required by the user. The data acquired can be recorded in the internal memory of the
apparatus and it can also be transferred to a USB stick for archiving or transfer to a PC. An Ethernet port is available to include the recorder in a PC network (TCP/IP).
Distributed I/O Module (HART) 589674 (46976-00)
The Distributed I/O Module (ET 200M) consists of an interface module from Siemens and permits to connect analog I/O's using HART communication protocol to a Siemens PLC through PROFINET communication. This I/O module features eight 4-20 mA HART analog inputs and eight 4-20 mA HART analog outputs.
All the I/O'S can be hardwired to both banana jacks and terminal blocks on the module front panel. Banana jacks provide an easy and fast way to wire a setup, while terminal blocks allow students to wire their setup in a way much closer to what is
commonly found in the industry.
This module has six switches that the instructor can use to insert faults.
Air Pressure/Flow Process Learning Systems, LabVolt Series
FOUNDATION Fieldbus Junction Box 588414 (46978-A0)
The FOUNDATION Fieldbus Junction Box is a device used to connect up to four field devices to a H1 segment. It can also be used to terminate an end of the cable run.
FOUNDATION Fieldbus Bridge 588415 (46979-10)
The FOUNDATION Fieldbus Bridge is a device used to establish a link between a computer, a PLC of the Logix5000 family (ControlLogix and CompactLogix), and a network of FOUNDATION Fieldbus devices. The FOUNDATION Fieldbus Bridge connects to the computer and the PLC via an Ethernet/IP network.
TIA Portal PLC Software (Step 7 Professional) with Process Device Manager (PDM) 589676 (46986-00)
The TIA Portal PLC Software (Step 7 Professional) is a programming software that is required for programming Siemens programmable logic controllers. Model 46986-0 also includes SIMATIC PDM (Process Device Manager) software for configuration, parameter assignment, commissioning, diagnostics and maintenance of intelligent field devices and automation components.
Air Pressure/Flow Process Learning Systems, LabVolt Series
TIA Portal PLC Software (Step 7 Professional) 592687 (46986-10)
The TIA Portal PLC Software (Step 7 Professional) is a programming software that is required for programming Siemens programmable logic controllers.
Instrumentation Mounting Pipe 582444 (46990-00)
The Instrumentation Mounting Pipe is a vertical pipe used to install instruments, usually differential-pressure transmitters, at the appropriate height and close to the point of measurement. The mounting pipe replicates the common industrial practice of installing a measuring instrument directly on the process pipe or on an adjacent one. The Instrumentation Mounting Pipe can be mounted on both sides of the Process Workstation or on the
Instrumentation Workstation.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Piping and Accessories (Air, Allen-Bradley) 588433 (46993-H0)
The Piping and Accessories (Air, Allen-Bradley) model includes a reel of tubing, a tube cutter, connectors, and other items required to use the air workstation. A manual needle valve is also included to control the flow of air in the process. An Allen-Bradley unmanaged switch also comes with the accessories.
Piping and Accessories (Air, Siemens) 589882 (46993-Q0)
The Piping and Accessories (Air, Siemens) model includes a reel of tubing, a tube cutter, connectors, and other items required to use the air workstation. A manual needle valve is also included to control the flow of air in the process. A Siemens unmanaged switch also comes with the accessories.
Optional Equipment Description
Touch-Screen Computer Mount (Optional) 589678 (3451-B0)
This sturdy mount allows the installation of the Touch-Screen Computer, Model 46299, on the side of the 3531 Instrumentation Workstation, Model 46900.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Touch Screen Graphic Terminal consists of an Allen-Bradley PanelView™ Plus 600 with a 14.5 cm (5.7 in) color display. This touch-screen interface allows the user to monitor and control many devices in the Pressure, Flow, Level, and Temperature Process Training Systems. The Touch Screen Graphic Terminal is pre-programmed with a control interface developed with the various components of the system in mind. The terminal also features an integrated EtherNet/IP communication port and an RS-232 serial port.
The FactoryTalk software, Model 46968, is optional and can be used to design your own control interface. A Rail Workstation, Model 3105, is required to install the Touch Screen Graphic Terminal on the system.
Process Control Signal Tower (Optional) 587869 (5924-C0)
The Signal Tower consists of three lights providing visual signals for various states of the Pressure, Flow, Level, and Temperature Process Training Systems. Lights are stacked one upon another, up to five modules. Each module is easily programmable without any special wiring or tools. An Acoustic Alarm, Model 52054, is available as an option.
Indicator-Light/Push-Button Station (Optional) 587871 (5925-A0)
The Indicator-Light/Push-Button Station consists of three industrial push-buttons, one normally closed and two normally open, used to operate the Pressure, Flow, Level, and Temperature Process Training Systems. The Indicator-Light/Push-Button Station also features three indicator lights. Both the push-buttons and the indicator lights operate at a voltage of 24 V dc. Electrical connections can be made using either the banana jacks or the terminal blocks available on the module. This module has four switches that the instructor can use to insert faults. A Rail Workstation, Model 3105, is required to install this device on the system.
SpecificationsParameter Value
Indicator Lights
Number 3
Color 1 green, 1 yellow, 1 red
Voltage Rating 24 V dc
Push Buttons
Number 3
Type 1 normally closed, 2 normally open
Voltage Rating 24 V dc
Faults Switches 4
Physical Characteristics
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Fuzzy Logic Software Add-On features Fuzzy Designer, an add-on to RSLogix 5000 which lets the user design and implement fuzzy logic algorithms on a controller of the Logix 5000 family. Fuzzy Designer includes an extensive component library to help the user quickly build algorithms that can be used in any RSLogix 5000 program. Two variants are available:
The Fuzzy Logic Software Add-On features Fuzzy Designer, an add-on to RSLogix 5000 which lets the user design and implement fuzzy logic algorithms on a controller of the Logix 5000 family. Fuzzy Designer includes an extensive component library to help the user quickly build algorithms that can be used in any RSLogix 5000 program. Two variants are available:
The Air Compressor is a quiet device well suited for classroom and school laboratories. It is provided with a tank, pressure regulator, pressure gauge, and a hose.
The Air Compressor is available in different variants depending on ac power network voltages and frequencies. Because of this, the actual module may vary from the one shown in the picture.
SpecificationsParameter Value
Power Requirements
Current 14.4 A
Power 1.125 kW (1.5 hp)
Service Installation Standard single-phase ac outlet
Tank Capacity 50 L (13 gal)
Flow Rate
Flow Rate (Free Flow) 180 L/min (6.3 CFM)
Flow Rate at 621 kpa (90 psi) 127 L/min (4.5 CFM)
Maximum Pressure 8 bar (116 psi)
Noise Level 42 dB/A (about as quiet as a refrigerator)
Physical Characteristics
Dimensions (H x W x D) 1041 x 330 x 686 mm (41 x 13 x 27 in)
Net Weight 69.9 kg (154 lb)
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Air Compressor is a quiet device well suited for classroom and school laboratories. The Air Compressor can be used to provide compressed air to different components. A conditioning unit, Model 6411-A, must be connected to the compressor for certain applications.
The Circulator Pump is available in different variants depending on ac power network voltages and frequencies. Because of this, the actual module may vary from the one shown in the picture.
SpecificationsParameter Value
Power Requirements
Current 4.8 A
Service Installation Standard single-phase ac outlet
Tank Capacity 15.1 L (4 gal)
Flow Rate 42.5 L/min at 620 kPa (1.5 SCFM at 90 psi)
Maximum Pressure 800 kPa (120 psi)
Noise Level 40 dB(A) (about as quiet as a refrigerator)
Physical Characteristics
Dimensions (H x W x D) TBE
Net Weight TBE
Personal Computer (Optional) 579785 (8990-00)
The Personal Computer consists of a desktop computer running
under Windows® 10. A monitor, keyboard, and mouse are included.
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Touch-Screen Computer is a compact solution for saving space in the classroom. It can be installed on a full-motion mount on the workstation to maximize desk space.
Touch-Screen Computer – Large (Optional) 589677 (46299-A0)
The Touch-Screen Computer is a solution for saving space in the classroom. It features a large 23-inch touch-screen and a high-speed processor. It can be installed on a full-motion mount, model 3451-A0 or 3451-B0, on the Instrumentation Workstation to maximize desk space.
Air Pressure/Flow Process Learning Systems, LabVolt Series
Digital Pressure Gauge (Low Range) (Optional) 588300 (46761-C0)
The Digital Pressure Gauge provides a direct reading of the pressure in one of many convenient measurement units. It features two interconnected pressure ports, an LCD display, and is equipped with a mounting bracket for simple installation on the workstation. The pressure gauge is available in two versions with different operating ranges:
The Storage Station is designed to store the accessories and the various optional models which are not required for the particular process taking place on the workstation.
It includes space to store up to four flange tops, many flowmeters and control valves on six galvanized struts (three on each side), a few devices on two instrumentation mounting pipes, and miscellaneous pieces of equipment in the three painted stainless-steel storage boxes at the bottom of the station.
The Storage Station is mounted on lockable casters to facilitate its mobility.
SpecificationsParameter Value
Physical Characteristics
Intended Location On the floor (stands on casters)
Dimensions (H x W x D) 1020 x 810 x 1830 mm (40.2 x 31.9 x 72 in)
Net Weight TBE
Air Pressure/Flow Process Learning Systems, LabVolt Series
The Instrumentation Workstation is designed to house the Electrical Unit, the Pneumatic Unit, as well as all other electrical components that are not measuring instruments. Devices such as controllers, PLCs, Color Paperless Recorders, and Touch Screen Graphic Terminals must be installed on the Instrumentation Workstation. This prevents the equipment from coming in contact with water.
The Instrumentation Workstation, Model 46900-G, does not include a Heating/Cooling Unit and is delivered already assembled.
Like the Process Workstation, the Instrumentation Workstation is a double-sided mobile workstation. Two groups of students can work on the system at the same time, one group on each side.
A hitch mechanism used to link the Instrumentation Workstation to the Process Workstation is part of the Piping and Accessories kit, Model 46993-C. This convenient piece of equipment makes it possible to move both stations as a single unit.
Pressure Switch (with Analog Output) (Optional) 588328 (46926-00)
The Pressure Switch with Analog Output is a digital pressure gauge ranging from 0 kPa (0 psi) to 1000 kPa (145 psi). It features a 4-20 mA output signal proportional to a user-defined upper value. A relay can be configured so as to become activated when the measured pressure rises above a threshold value.
The Pressure Transmitter is a gauge pressure measurement device for the fluids in the Pressure, Flow, Level, and Temperature Process Training Systems. This rugged and reliable device has a high accuracy and supports one of two communication protocols: HART or FOUNDATION Fieldbus.
The Pressure Transmitter is a gauge pressure measurement device for the fluids in the Pressure, Flow, Level, and Temperature Process Training Systems. This rugged and reliable device has a high accuracy and supports one of two communication protocols: HART or FOUNDATION Fieldbus.
Pneumatic Control Valve for Air with a Positioner - Fisher 3660 (Optional) 588367 (46953-B0)
The Pneumatic Control Valve for Air is a normally closed stainless steel valve with 1/4 inch connectors designed to regulate the flow of air. This compact valve features a rugged construction and good control characteristics over the air flow. The Pneumatic Control Valve (Air) includes a current-to-pressure converter which transforms a 4-20 mA input signal into a pneumatic signal sent to the actuator of the valve.
This control valve is available in different versions which can include a positioner. The various versions are:
46953-00 Pneumatic Control Valve (Air)46953-A0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 200046953-B0 Pneumatic Control Valve for Air with a Positioner - Fisher 366046953-C0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 6000
46953-D0 Pneumatic Control Valve for Air with Digital Positioner (FOUNDATION Fieldbus) - DVC 6000
Table of Contents of the Manual(s)
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
Manual
DescriptionManual number
Control Valves (User Guide) __________________________________________________________585145 (86001-E0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 6000 (Optional) 588368 (46953-C0)
The Pneumatic Control Valve for Air is a normally closed stainless steel valve with 1/4 inch connectors designed to regulate the flow of air. This compact valve features a rugged construction and good control characteristics over the air flow. The Pneumatic Control Valve (Air) includes a current-to-pressure converter which transforms a 4-20 mA input signal into a pneumatic signal sent to the actuator of the valve.
This control valve is available in different versions which can include a positioner. The various versions are:
46953-00 Pneumatic Control Valve (Air)46953-A0 Pneumatic Control Valve for Air with Digital Positioner (HART) -
DVC 200046953-B0 Pneumatic Control Valve for Air with a Positioner - Fisher 366046953-C0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 600046953-D0 Pneumatic Control Valve for Air with Digital Positioner (FOUNDATION Fieldbus) - DVC 6000
Table of Contents of the Manual(s)
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
Pneumatic Control Valve for Air with Digital Positioner (FOUNDATION Fieldbus) - DVC 6000 (Optional) 588369 (46953-D0)
The Pneumatic Control Valve for Air is a normally closed stainless steel valve with 1/4 inch connectors designed to regulate the flow of air. This compact valve features a rugged construction and good control characteristics over the air flow. The Pneumatic Control Valve (Air) includes a current-to-pressure converter which transforms a 4-20 mA input signal into a pneumatic signal sent to the actuator of the valve.
This control valve is available in different versions which can include a positioner. The various versions are:
46953-00 Pneumatic Control Valve (Air)
Manual
DescriptionManual number
Control Valves (User Guide) __________________________________________________________585145 (86001-E0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
46953-A0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 200046953-B0 Pneumatic Control Valve for Air with a Positioner - Fisher 366046953-C0 Pneumatic Control Valve for Air with Digital Positioner (HART) - DVC 600046953-D0 Pneumatic Control Valve for Air with Digital Positioner (FOUNDATION Fieldbus) - DVC 6000
Table of Contents of the Manual(s)
Control Valves (User Guide) (585145 (86001-E0))1 Basic Control Valve Theory2 Basic Control Valve (46950-B)3 Pneumatic Control Valve with a Positioner (46950-A)4 Control Valve with DVC2000 (46950-0)5 Control Valve with DVC6000 – HART/FF (46950-E/-D)6 Control Valve with DVC6200 – HART/FF (46950-E/-D)7 Electric Control Valve (46950-C)
FactoryTalk View ME Studio (Educational) (Optional) 588384 (46968-00)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)
Manual
DescriptionManual number
Control Valves (User Guide) __________________________________________________________585145 (86001-E0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
Windows® 8.
FactoryTalk View ME Studio (with Foxboro OPC Server, Educational) (Optional) 588395 (46968-10)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
Windows® 8.
FactoryTalk View ME Station (Educational) (Optional) 588397 (46968-20)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
FactoryTalk View ME Station (with Foxboro OPC Server, Educational) (Optional) 588398 (46968-30)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
FactoryTalk View ME Studio (Commercial) (Optional) 588385 (46968-A0)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial) (Optional) 588387 (46968-B0)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
FactoryTalk View ME Station (Commercial) (Optional) 588390 (46968-C0)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
FactoryTalk View ME Station (with Foxboro OPC Server, Commercial) (Optional) 588391 (46968-D0)
FactoryTalk View is a Windows-based application suite, produced by Rockwell Software, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and small processes. This versatile suite is compatible with a wide array of devices, including PLCs and Foxboro controllers, and constitutes a distributed control system development solution of choice.
HMI applications are developed and edited using FactoryTalk View Studio, which also has limited runtime capabilities to test your interface. A completed application can be loaded directly on a Touch Screen Graphic Terminal, Model 5922 or 46973, as it includes a built-in runtime software. Your applications can also
be designed to run on a computer, but doing so requires the purchase of FactoryTalk View Machine Edition Station Runtime.
A bundle (Model 46968-1 or -B) consisting of FactoryTalk View Studio and a Foxboro OPC server is available to enable communication and data exchange between a Foxboro controller (Model 46960) and a computer.
Available versions:
46968-0 FactoryTalk View ME Studio (Educational)46968-1 FactoryTalk View ME Studio (with Foxboro OPC server, Educational)46968-2 FactoryTalk View ME Station (Educational)46968-3 FactoryTalk View ME Station (with Foxboro OPC server, Educational)46968-A FactoryTalk View ME Studio (Commercial)46968-B FactoryTalk View ME Studio (with Foxboro OPC Server, Commercial)46968-C FactoryTalk View ME Station (Commercial)46968-D FactoryTalk View ME Station (with Foxboro OPC server, Commercial)
SpecificationsParameter Value
Computer RequirementsA currently available personal computer running under one of the following operating systems: Windows® 7 or
Industrial PC HMI (Siemens) (Optional) 589672 (46973-A0)
The Industrial PC HMI consists of a Siemens 477D Industrial PC with a 48.2 cm (19 in) color display. This touch-screen interface allows monitoring and control of some features of the Pressure, Flow, Level, and Temperature Process Training Systems. The Touch Screen Graphic Terminal is pre-programmed with a control interface developed with the various components of the system in mind. It features an integrated PROFINET communication port, three USB ports and DVI port to connect an extra large monitor for presenting démonstrations to a large student group. The Industrial PC includes Windows 7 Ultimate and WinCC Runtime software.
The WinCC Advanced development software, Model 46984, is optional and can be used to design your own control interface.
Calibration Kit (Optional) 588416 (46980-00)
The Calibration Kit includes the equipment required to precisely adjust the control valves and to perform diagnostic tests on electrical devices. The kit contains a Fluke 725 multifunction process calibrator which can act as a source and measure different parameters. A calibration pump completes the kit and is used to calibrate pressure devices.
A Calibration Kit, Model 46980 or 46981, is required to characterize and tune processes in the Pressure, Flow, Level, and Temperature Process Training Systems.
Calibration Kit with Pressure Modules (Optional) 588417 (46980-A0)
The Calibration Kit is a variant of the Calibration kit, Model 46980-0, that also includes a Fluke 725 multifunction process calibrator and pressure modules (a test pump and two pressure gauges) for reliable measurement of pressure directly on the Fluke calibrator.
The Calibration Kit includes the equipment required to precisely adjust the control valves, perform diagnostic tests, and interface with smart devices.
This version of the kit contains a Fluke 754 documenting process calibrator with HART capabilities to calibrate, maintain, and troubleshoot HART devices. The Fluke calibrator acts as a source and measures pressure, temperature, and electrical signals.
It also include a test pump used to generate a wide range of pressures from vacuums at -95 kPa (-13.9 psi) to pressures up to 410 kPa (600 psi). Two pressure gauges, a low-range version (up to 34 kPa (5 psi)) and a high-range version (up to 690 kPa (100 psi)), are included and can be used with the Fluke calibrator for direct measurement of pressure.
A Calibration Kit, Model 46980 or 46981, is required to characterize and tune processes in the Pressure, Flow, Level, and Temperature Process Training Systems.
Available Calibration Kits:
46981-0 Calibration Kit (HART)46981-A Calibration Kit (HART and FOUNDATION Fieldbus)
Calibration Kit (HART and FOUNDATION Fieldbus) (Optional) 588419 (46981-A0)
The Calibration Kit includes the equipment required to precisely adjust the control valves, perform diagnostic tests, and interface with smart devices.
This version of the kit is compatible with both HART and FOUNDATION Fieldbus. It includes the Emerson AMS Trex™ Device Communicator: a universal HART and FOUNDATION Fieldbus communicator. The kit also contains a Fluke 725 multifunction process calibrator which can act as a source and measure different parameters.
It also include a test pump used to generate a wide range of pressures from vacuums at -95 kPa (-13.9 psi) to pressures up to 410 kPa (600 psi). Two pressure gauges, a low-range version (up to 34 kPa (5 psi)) and a high-range version (up to 690 kPa (100 psi)), are included and can be used with the Fluke calibrator for direct measurement of pressure.
A Calibration Kit, Model 46980 or 46981, is required to characterize and tune processes in the Pressure, Flow, Level, and Temperature Process Training Systems.
Available Calibration Kits
46981-0 Calibration Kit (HART)46981-A Calibration Kit (HART and FOUNDATION Fieldbus)
The Software Configurator includes the FieldCare software necessary to interpret the data related to the different smart devices and to configure their parameters. The HART version also includes a communication box for data transfer between a HART device and a PC with a USB port.
FOUNDATION Fieldbus Software Configurator (Optional) 588421 (46982-A0)
The Software Configurator includes the FieldCare software necessary to interpret the data related to the different smart devices and to configure their parameters. The FOUNDATION Fieldbus version makes use of the FOUNDATION Fieldbus Bridge, Model 46979-1.
The Software Configurator includes the FieldCare software necessary to interpret the data related to the different smart devices and to configure their parameters. The HART version also includes a communication box for data transfer between a HART device and a PC with a USB port. The FOUNDATION Fieldbus version makes use of the FOUNDATION Fieldbus Bridge instead, Model 46979-1.
The WinCC Advanced development software is a Windows-based application suite, produced by Siemens, which simplifies the creation of graphic human-machine interfaces (HMI), such as operator interface solutions, to monitor and control machines and industrial processes.
A completed application provided with WinCC can be used with a S7-1500 Siemens PLC and a 3531 System to perform process control experiments. The HMI database can be loaded
directly on an Industrial PC, Model 46973-A0. Your applications can also be designed to run on a computer, model 46299 or 46299-A0.
Custom Computer for SCADA (Optional) 588440 (46999-00)
The Custom Computer for SCADA is designed to ensure full compatibility with the SCADA system as well as long-term reliability and efficiency.
The optional preferred software for SCADA such as FactoryTalkView, WinCC is pre-installed along with the other optional PLC programming software ordered at the same time, such as RSLogix Micro, RSLogix 5000 or Step7 TIA Portal. All the software are registered to the training facility.
The computer model includes a 23-inch Touch-Screen Computer that is a compact solution for saving space in the classroom. It can be installed on a full-motion mount on the workstation to maximize desk space. An
optional computer-mount is also available to attach the computer to the Instrumentation Workstation.
SpecificationsParameter Value
Power Requirements
Current TBE
Service Installation Standard single-phase ac outlet
Instrumentation and Process Control Training System - Optional Manuals (Manuals on CD-ROM) (Optional) 585124 (85990-A0)
Air Pressure/Flow Process Learning Systems, LabVolt Series
Reflecting the commitment of Festo Didactic to high quality standards in product, design, development, production, installation, and service, our manufacturing and distribution facility has received the ISO 9001 certification.