Top Banner
Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O-Convect - Touchline Quick Installation Guide Rev: B - 12/11/2018
12

Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Jun 18, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O-Convect - Touchline

Quick Installation Guide

Rev: B - 12/11/2018

Page 2: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Index

Page 1

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Installation

Filtration System 4

Positioning 5

Drainage Connection 6

Detergent Tray (6 Grid, 10 Grid) 7

Oven Cleaner Connection (20 Grid) 7

Water Connection 8

Electrical Oven - Power 9

Gas Oven - Power 9

Total Dissolved Solids (TDS) Test 3

Chloride Test 3

Information

Electrical and Gas Connection 2

Water Connection 2

Attention 2

Page 3: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Information

Page 2

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Attention

Disclaimer:

The manufacturer and distributor cannot be held responsible or liable for any injuries or damages of any kind occurred to persons, appliances or others, due to abuse and misuse of this appliance in regards to installation, un-installation,

operation, servicing or maintenance, or lack of conformity with the instructions indicated in this documentation.

All appliances made by the manufacturer are delivered assembled, where possible, and ready to install. Any installation, un-installation, servicing, maintenance and access or removal of any parts, panels or safety barriers that is not

permitted, does not comply in accordance to this documentation, or not performed by a TRAINED AND AUTHORISED SPECIALIST will result in the IMMEDIATE LOSS OF THE WARRANTY.

The manufacturer cannot be held responsible or liable for any unauthorized modifications or repairs. All modifications or repairs must be approved by the manufacturer in writing before initiating. All modifications or repairs performed to

this appliance must be performed at all times by a TRAINED AND AUTHORISED SPECIALIST.

Read through the following instructions carefully before proceeding with the installation. Be sure to follow all relevant standard and local codes. Please contact the Stoddart Service Department at 1300 307 289 if you are having problems with the installation of the unit.

Information

• This unit must be connected to an adequate supply of filtered potable water. (See page 3-4 for selection of an appropriate filter system)• This unit must be connected to a waste water disposal system that:

(a) will effectively dispose of all waste water; and (b) is constructed and located so that there is no likelihood of the waste water polluting the water supply or contaminating food.

• Regulations require that all units be installed to the appropriate Australian standards.• Regulations require that authorised persons carry out all plumbing work.

Water Connection

IMPORTANT!This unit must be installed in accordance with AS/NZS 3500.5

Information

• The electrical and/or gas supply must comply with the rating plate data.• Ensure that the machine is connected to a suitably rated, dedicated and earthed power source with its own isolation switch.

Extension leads or power boards are not to be used.• Regulations require that all units be installed to the appropriate Australian standards.• Regulations require that authorised persons carry out all electrical and/or gas work.• Users should also note that if the supply electricity cord is damaged in any way it should be replaced. Please contact Stoddart for parts

and we will advise how to do this in order to avoid any electrical hazard.• The power cable should be dry and or isolated from moisture or water.

Electrical and Gas Connection

WARNING!This unit must be installed in accordance with

AS/NZS 60335.1, AS/NZS5601

Page 4: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 3

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Chloride Test1. Remove Titrator from bottle and

replace bottle cap immediately.

2. Insert lower end of the Titrator into water to be tested (approx 20mm of water). DO NOT allow water to touch yellow completion band at top of Titrator.

3. Allow water to completely saturate the wick of Titrator. Reaction is complete when yellow band turns dark.

4. Note where the white chloride peak falls on the scale. This represents the unit value.

5. Refer to the table to convert the Titrator units into salt concentration. * Readings higher than 1.4 (32PPM) require a Reverse Osmosis Unit to be installed.

Total Dissolved Solids (TDS) Test1. Remove the cover from the TDS meter,

turn on by pressing the On/Off button. The display should read 000.

2. Insert lower end of the TDS meter into water to be tested (approx 20mm of water). DO NOT completely submerge.

3. Wait 5-10 seconds.

4. The number displayed on meter is the TDS (Total Dissolved Solids) of the water expressed in PPM (parts per million) e.g. TDS = 220PPM.

5. When finished, turn the TDS meter off.

1

2

3

4

5

6

7

8

9

1

2

3

4

5

6

7

8

9

1

2

3

1.41.61.82.02.22.42.62.83.03.23.43.63.84.04.24.4

0.0050.0060.0070.0090.0100.0110.0130.0140.0160.0170.0190.0210.0230.0250.0270.030

323945536068778695

106116128140152166180

4.64.85.05.25.45.65.8

0.0320.0350.0380.0410.0440.0480.051

196212229248267288311

6.0 0.055 3356.2 0.060 3616.4 0.064 3896.6 0.069 4196.8 0.074 4527.0 0.080 4877.2 0.087 5257.4 0.093 5677.6 0.101 613

Units %NaCI CI Units %NaCI CI

ppm(mg/L)

Limit*

ppm(mg/L)

IMPORTANT!Selection of the correct water filtration system to suit local water

conditions is CRITICAL. Failure to install the correct system according to the following guidelines will void warranty.

Page 5: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 4

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

WaterSupply Test

CallStoddart

1300 307 289

Chloride(Cl)

TDS

Greater Than32PPM (Parts Per Million)

BWT Unit

Reverse Osmosis Unit

Less Than32PPM

Less Than60PPM

Greater Than60PPM

Filtration System• After testing the quality of your water supply use the below chart to determine you water filter requirements.

Page 6: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 5

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

300mm

500mm

Minimumclearance from

non-heat source

Minimumclearance from

heat source

Positioning• The oven must be installed under an

extraction canopy that meets AS 1668.2.

• To allow access to service panel and protection of the control components, the left hand side of the Combi oven must have the following minimum clearances: Heat Source: - 500mm clearance from another heat source, in order to protect the oven control components and allow access to the service panel. Non-Heat Source: 300mm clearance from a non-heat source to allow access to the service panel.

• Failure to adhere to these clearances will potentially void the oven warranty or add service costs due to lack of access.

• Using a spirit level, ensure that the Combi oven is level. Adjust the foot height to level Combi oven.

• If using a stand, level the stand by adjusting the feet, then level the Combi oven.

Page 7: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 6

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Drainage Connection• Drain kit is supplied with oven as

illustrated. Any modification or extension to the kit must be able to resist temperatures up to 100°C.

• Plumb supplied waste pipes to the Tundish.

• Tundish needs to be a minimum of 300mm left or right from the oven waste outlet.

• Tundish should never be located directly below the waste outlet, or close to or under the oven control compartment. Steam from drainage should not be allowed to rise up underneath the oven control compartment.

• Waste pipe must sit 25mm above the Tundish.

• Secure waste pipe to the Combi oven. Securing bracket is attached to top of the Combi oven. Remove screw, reposition bracket, then secure in place with previously removed screw.

25mm

300mm

300mm

Oven Waste Outlet

25mm

300mm

300mm

Oven Waste Outlet

Page 8: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 7

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Oven Cleaner Connection (20 Grid)• Connect the oven cleaner and rinse aid

hoses to oven. - Rinse aid (blue) on left side. - Oven cleaner (red) on right side.

• Attach correct hoses directly to oven cleaner and rinse aid bottles.

Detergent Tray (6 Grid, 10 Grid)• Connect locking pin to underside of

oven.• Insert bracket into holes located on

underside of oven.• Slide detergent tray between bracket

and oven. Secure by rotating the locking pin clockwise 90°.

• Detergent tray is split into two compartments: - Rinse aid (blue) on left side. - Oven cleaner (red) on right side.

RINSE

DETERGENT

Optional Storage Rack

Oven Cleaner(Red)Rinse Aid

(Blue)

90°

Page 9: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 8

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

CWI-1Filtered Water

CWI-2Non Filtered Water

Water SupplyWith

Isolation Valve

Water FlowDirection

FiltrationSystem

150-350 kPa(22-65 psi)

150-350 kPa(22-65 psi)

No FiltrationSystem

Minimum Flow RateRefer to specificinstallation guidesupplied with the

water filter10LPM flow rate6,10,10x2 tray oven

20LPM flow rate20,40 tray oven

FE

D

SuppliedConnectors

RO Filter

BWT Filter

B

C

A

Water Connection• Water connections are labelled on the

service panel.• Isolation valve must be installed at the

water supply outlet.• CWI-1: The Combi oven requires

filtered water supplied to its steam generation system. Water pressure must be150-350 kPa (22-65 psi) at oven connection.

• CWI-2:The Combi oven requires unfiltered water supplied to its wash system. Water pressure must be150-350 kPa (22-65 psi) at oven connection. Minimum flow rate: 10LPM - 6,10,10x2 tray oven. 20LPM - 20,40 tray oven.

BWT Filter Supplied Connectors:• A: Manifold fitting with 1 cap x1• B: Non-Return Valve x1• E: 3/4 BSB Hex Nipple x1

RO Filter Supplied Connectors:• D: Manifold fitting with 2 caps x1• E: Non-Return Valve x1• F: 3/4 BSB Hex Nipple x1

Page 10: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Installation

Page 9

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Electric Oven - Power• Oven is to be wired to the electrical

supply by a licensed technician in accordance with AS/NZS60335.1.

• Supply must have an isolation switch.• Remove the two screws at the base

of the service panel, remove service panel.

• Correctly wire the oven to terminal.• Re-install service panel.

Electric OvenElectric Oven

Gas Oven - Power• Gas ovens only.• Oven is to be connected to the gas

supply by a licensed technician in accordance with AS/NZS5601.

• Supply must have an isolation valve.• Connect gas line to gas connection on

underside of oven.• Stoddart is to be contacted for the gas

setting adjustment. Ph:1300307289• No external appliance gas regulator is

required.• The ovens electrical connection is

supplied via a 10Amp plug and lead, for connection to an appropriately rated GPO.

GasSupply

Page 11: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Notes

Page 10

Due to continuous product research and development,the information contained herein is subject to change without notice.

www.stoddart.com.auwww.stoddart.co.nz

Page 12: Air-O-Steam, Air-O-Steam - Touchline, Air-O-Convect, Air-O ......Due to continuous product research and development, the information contained herein is subject to change without notice.

Page 11

www.stoddart.com.au

InternationalSales

Tel: +617 3440 7600

Email: [email protected]

Service / Spare Parts

Tel: +617 3440 7600

Email: [email protected]

Email: [email protected]

www.stoddart.co.nzNew Zealand Business Number: 6837694

New ZealandSales

Tel: 0800 79 1954

Email: [email protected]

Service / Spare Parts

Tel: 0800 935 714

Email: [email protected]

Email: [email protected]

www.stoddart.com.auAustralian Business Number: 16009690251

AustraliaSales

Tel: 1300 79 1954

Email: [email protected]

Service / Spare Parts

Tel: 1300 307 289

Email: [email protected]

Email: [email protected]