AIR & EMISSIONS Matrices consisting of organic, inorganic, and particulate matter for testing emissions and ambient air. Standards are designed to meet regulations of the United States Environmental Protection Clean Air Act and may be used to satisfy PT requirements worldwide. 2020 Air & Emissions PT Schedule 2021 Schedule subject to change – see Waters ERA’s website at www.eraqc.com Scheme # Opens Closes Q AE 51 Jan 27 Mar 12 Q AE 52 Apr 27 Jun 11 Q AE 53 Jul 27 Sep 10 Q AE 54 Oct 23 Dec 7 Scheme # Opens Closes Q AE 55 Jan 29 Mar 15 Q AE 56 Apr 26 Jun 10 Q AE 57 Jul 30 Sep 13 Q AE 58 Oct 29 Dec 13 52 For the latest products and information, please visit us online at www.eraqc.com
6
Embed
AIR & EMISSIONS documents/6164_CT_2020... · AIR & EMISSIONS Matrices consisting of organic, inorganic, and particulate matter for testing emissions and ambient air. Standards are
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
AIR & EMISSIONSMatrices consisting of organic, inorganic, and particulate matter for testing emissions and ambient air. Standards are designed to meet regulations of the United States Environmental Protection Clean Air Act and may be used to satisfy PT requirements worldwide.
2020Air & Emissions PT Schedule
2021
Schedule subject to change – see Waters ERA’s website at www.eraqc.com
Scheme # Opens Closes
Q AE 51 Jan 27 Mar 12
Q AE 52 Apr 27 Jun 11
Q AE 53 Jul 27 Sep 10
Q AE 54 Oct 23 Dec 7
Scheme # Opens Closes
Q AE 55 Jan 29 Mar 15
Q AE 56 Apr 26 Jun 10
Q AE 57 Jul 30 Sep 13
Q AE 58 Oct 29 Dec 13
52 For the latest products and information, please visit us online at www.eraqc.com
CRM: A reference material characterized by a metrologically valid procedure for one or more specified properties, accompanied by a reference material certificate that provides the value of the specified property, its associated uncertainty, and a statement of metrological traceability.
A complete listing of ERA’s CRMs can be found on our Scope of Accreditation for general requirements for competence of reference material producers available at www.eraqc.com/AboutERA/Accreditations.
PT: A Proficiency Test (PT) is an analysis of what is often referred to as a blind sample or a sample with unknown concentrations of analytes for the purpose of evaluating a laboratory’s analytical performance.
QR: Similar to a Proficiency Test, a QuiK Response (QR) is a sample with unknown concentrations. However, unlike a scheduled PT, QR is on-demand and available at any time. Plus, your results are returned within two business days. QuiK Response can be used as a bilateral PT as referenced in the IUPAC/CITAC guide: Selection and use of PT schemes for a limited number of participants – chemical analytical labs.
RM: A material, sufficiently homogeneous and stable with respect to one or more specified properties, which has been established to be fit for its intended use in a measurement process.
54 For the latest products and information, please visit us online at www.eraqc.com
Volatiles
Volatiles on Sorbent
CRM Cat. #1101
PT Cat. #1001 Q QR
Cat. #1101QR
One 2 mL flame-sealed ampule for spiking client-specific sorbent. Use with EPA Methods TO-17, 0030, 0031, or other applicable methods. Contains at least 24 analytes, randomly selected from the list below, at 50–2000 ng/sample (200–3000 ng/sample for Total Xylenes) after preparation.
One pressurized gas cylinder containing 87 L of gas at 1500 psig (103 bar) for use with EPA methods TO-14, TO-15, or other applicable methods. Contains at least 10 analytes, randomly selected from the list below, at 2-50 ppbv (4-100 ppbv) for Total Xylenes.
CRM – Certified Reference Material PT – Proficiency Testing QR – QuiK Response RM – Reference Material
Semivolatiles
PAHs on Polyurethane Foam
CRM Cat. #1113
PT Cat. #1013 Q QR
Cat. #1113QR
One 2 mL flame-sealed ampule plus one polyurethane foam. Use with EPA Method TO-13A, or other applicable methods. Contains at least 13 analytes, randomly selected from the list below, at 10–200 µg/sample after preparation.
One 2 mL flame-sealed ampule to be spiked onto sorbent. Use with EPA Method TO-11A, or other applicable methods. Contains at least four analytes, randomly selected from the list below, at 0.5–10 µg/sample after preparation.
One 2 mL flame-sealed ampule plus one polyurethane foam. Use with EPA Methods TO-04A, TO-10A, or other applicable methods. Contains at least 16 analytes, randomly selected from the list below, at 1–20 µg/sample after preparation.
Two 2 mL flame-sealed ampules plus one polyurethane foam. Use with EPA Method 0010, or other applicable methods. Contains at least 42 analytes, randomly selected from the list below, at 10–225 µg/sample (200–1000 µg/sample for Benzidine) after preparation.
One 2 mL flame-sealed ampule plus one polyurethane foam. Use with EPA Methods TO-04A, TO-10A, or other applicable methods. Contains one aroclor, randomly selected from the list below, at 2–10 µg/sample after preparation.
56 For the latest products and information, please visit us online at www.eraqc.com
Metals
Mercury in Impinger Solution
CRM Cat. #1128
PT Cat. #1028 Q QR
Cat. #1128QR
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA Methods 29, 101a, or other applicable methods.
One filter paper sample packaged in a 50 mm polystyrene petri dish containing a single 47 mm tissue quartz filter spiked with lead ready-for-use with EPA Method 12 or other applicable methods.
One impinger solution sample packaged in a 15 mL screw top vial containing approximately 14 mL of standard concentrate for use with EPA Method 12, or other applicable methods.
One filter paper sample packaged in a 50 mm polystyrene petri dish containing a single 47 mm fiber film filter for use with CARB Method 425, or other applicable methods.
Total chromium ............................................................................................................................................................... 1–20 µg/filterHexavalent chromium ............................................................................................................................................. 1–20 µg/filter
Hexavalent Chromium in Impinger Solution
CRM Cat. #1132
PT Cat. #1032 Q QR
Cat. #1132QR
One impinger solution sample packaged in a 15 mL screw top vial containing approximately 14 mL of standard concentrate for use with EPA Method 0061/7199, or other applicable methods.
One filter paper sample packaged in a 50 mm polystyrene petri dish containing a single 47 mm tissue quartz filter ready for use with EPA Method 29 or other applicable methods.
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA Method 29, or other ap-plicable methods.
One 2 mL flame-sealed ampule containing approximately 2 mL of standard concentrate and a 50 mm polystyrene petri dish containing a single 47 mm glass fiber filter. Sample is ready for use with EPA Method 29, or other applicable methods.
CRM – Certified Reference Material PT – Proficiency Testing QR – QuiK Response
Inorganics
Sulfuric Acid & Sulfur Dioxide in Impinger Solution
CRM Cat. #1144
PT Cat. #1044 Q QR
Cat. #1144QR
One impinger solution sample packaged in a 15 mL screw top vial containing approximately 14 mL of standard concentrate for use with EPA Method 8, or other applicable methods.
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA CTM 027, or other applicable methods.
One filter paper sample packaged in a 50 mm polystyrene petri dish containing a single 47 mm tissue quartz filter ready for use with EPA Methods 5, 5A, 5B, 5D, 5F, or other applicable methods.
One impinger solution sample packaged in a 250 mL polyethylene bottle containing approximately 250 mL of standard ready for use with EPA Methods 5, 5A, 5B, 5D, 5F, or other applicable methods.
Two impinger solution samples packaged in 15 mL screw-top vials containing approximately 14 mL of standard concentrate for use with EPA Methods 26, 26a, or other applicable methods.
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA Methods 13a, 13b, 14, or other applicable methods.
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA Method 7, or other applicable methods.
Oxides of nitrogen (NOx).................................................................................................................. 100–2000 mg/dscm
Sulfur Dioxide in Impinger Solution
CRM Cat. #1143
PT Cat. #1043 Q QR
Cat. #1143QR
One impinger solution sample packaged in a 15 mL screw-top vial containing approximately 14 mL of standard concentrate for use with EPA Method 6 and Method 8, or other applicable methods.