Vertical CondensingUnit A Series Horizontal Discharge
Condensing UnitF Series Ducted Split
B & D Series Ducted SplitBR & ER Series Air-Cooled Rooftop
A Series
50Hz, 60Hz
50Hz, 60Hz
50Hz
50Hz
50Hz
ElectricalSupply
AVCU 25/30/35/40/50/60A
2.78~16.41
2.78~16.41
ACC 10/15/20/25/28/30/38/40/50/60C/CR
Ceiling Concealed C Series
50Hz, 60HzCeiling ConcealedD &E Series
ACC 75/100 D/DR (Very High Static)ACC 75/100 E/ER (High Static)
50Hz
21.96 – 29.31
22.27 – 32.24
Protection 1
Ideal blend of style and function. Regular cleaning is easier by just wiping the flat front panel.This ensures the air-conditioner will always look brand new all the time.
Wall Mounted J series
ALC 09/15 C/CR
AWM 09/15/20/25 J/JR
Bio-Pro is an IAQ solution which combines superior cleansing and purifying of Bio Antibody filter with more effective deodorizing features of Titanium Apatite filter.Working in tandem, both technologically-advanced air filters offer higher level of IAQ and room comfort.*Bio-Pro is offered as optional accessories.
Bio-engineering is the fusion of life science with engineering principles that creates exciting new solutions to considerably enhance the needs of modern lifestyle.Using advanced bio-engineering techniques, the Bio Antibody filter is able to eliminate up to 99.99%* of various airborne infectious viruses to provide a cleaner and more purified living environment.
100%
0.01%60s
Virus Removal Rate • Deactivates influenza virus within 1 minute*.• Effective against the common H1N1 and H3N2 Type-A influenza viruses.• Neutralization of virus as a result of natural antigen-antibody reaction.
* Proven through joint research with Waseda University (Japan), Japanese Ministry of Health, Labor & Welfare and National Institute of Infectious Diseases (Japan).
Through immunization process,a healthy hen is injected with
antigen to stimulate the productionof natural IgY antibodies.
Eggs produced by immunized hen also contains IgY antibodies.
The egg yolk liquid is removed and by centrifugal separation,
pure IgY is obtained. After sterilization and spray dry,IgY powder is applied on special moisture-retaining filter material.
By method of deposition, high concentration of IgY is extracted.
Antigen
Centrifugal WaterSoluble
IgY
IgY IgYIgY
IgY
IgY
IgYIgY IgY
IgY
IgY
IgYIgYIgY
IgY
Hen Egg
No longer harmful to room occupants. Air is fresher.
IgY Antibody
Bio-Antibody FilterSpecial filter material thatcontains IgY antibodies
Deactivates 99.99% of airborneinfections viruses within 1 minit
Deactivated even if itbecomes airborne again
Free floating viruses and antigen causes potential health hazards and discomfort to the room occupants.
Airborne Virus
AWM 09/15/20/25 J/JR
Cooling:8400 Btu/h - 24000 Btu/h2.46 kW - 7.03 kW
Heating:9000 Btu/h - 25000 Btu/h2.64 kW - 7.33 kW
Wall Mounted ALC 20/25 C/CR
4 5
Wall Mounted J series
Protection 2Micron-scale fibers trap dust while titanium apatite adsorbs organic contaminants such as bacteria and viruses. In addition, the titanium oxide is activated by natural light, allowing it to break down and eliminate odours. The filter effectively deactivates bacteria and viruses. It lasts for three years without replacement if washed about once every six months.
• Absorption of dangerous airbone particles like dust, pollen and cigarette smoke.• Dissolves odor, bacteria and virus.
• Photo catalytic deodorizing filter• Mechanism of photo catalytic. - Titanium Oxide is activated by exposure to light. - Becomes highly oxidative. - Dissolves absorbed sunstances into harmless water (H2O) and carbon dioxide (CO2).
NaturalSunlight
Step 1 Step 2 Step 3
When photocatalyst is exposed to light, it is activated and absorbs odor particles
A chemical reaction decomposes the odors into CO2 and H2O
The odorless substances and thenreleased into the air.
Deactivated
ActiveAirborne
Virus
Decomposed
Power to absorbbacteria and
virusesmore than
DOUBLED!
Dissolutionefficiency
is alsoimproved
TURBO function is available in COOL & HEAT modes only. Once it is activated, the air-conditioner will run into full power with indoor fan running at MAX speed for 20 minutes. This enables the set temperature to be achieved faster. If TURBO and SLEEP are activated at the same time, the SLEEP mode timer will be reset, it will resume after TURBO function is cleared.
T room
T set
20min 30min
Power Failure Power Failure
E2 PROME2 PROM
Operation Stop Restart
Setting stored before power failure.
With up to five selectable fan speeds, users are given more choices. By selecting Quiet mode, the sound pressure level can be reduced down to an unobtrusive 25 dBA.
GS02 Handset
6 7
Once activated, sleep mode ensures a comfortable environment for restful sleep. Depending on the mode, set temperature is increased / decreased gradually according to normal sleeping temperature patterns.
-3˚C
* Heat pump models only
Cooling
Hou
rs
Tem
pera
ture
Sleep Set On
0 1/21
2Cooling mode
+0.5˚C+0.5˚C
+1˚C
Heating
Hours
Tem
pera
ture
Sleep Set On
-1˚C
-2˚C
0 1/2 12
Heating mode*
• Prominent 40mm temparature display.• Real-time clock display.• Dedicated buttons for Silent and Turbo functions.
AWM 301/301RCombining the advantages of a wall-mounted unit with improved cooling / heating capacity, AWM301/301R is ideally designed for large key features include:• Uniform Air Distribution - automated air swing ensures conditioned air distributed evenly.• Quiet Operation - random-pitched fan blade delivers high air flow at lower sound level.• Easy Maintenance - air intake grille is detachable and cleaned with water.
In the event of a sudden power failure during operation, unit can be automatically restarted in 64 different recovery timing patterns and the unit will operate base on the previous setting (Operating Mode, Temperature Setting and Fan Speed). This ensures that air conditioners in the same building resume randomly instead of all at the same time, preventing power surges after a blackout.
ACC 10/15/20/25 C
Indoor Unit:
A
B
COMP. A
COMP. B
AMSD Series: Double Compressor 2-Indoor Split System
A
B
COMP. A
COMP. B
CCOMP. C
AMST Series: Triple Compressor 3-Indoor Split System
AWM 10/15/20/25 G2/G2R
Acson offers a very comprehensive range of Multi-Split condensing units, right from System 2 (1 outdoor to 2 indoors) up to System 3. In addition, each of the product range has various cooling/heating capacity combinations.
Only 1 outdoor is need to couple with 2 or more indoors. Thus, this has effectively improving the floor space utilisation. The Multi-Split models are especially popular in the apartment and condominium application where the floor space is very limited.
G18 Handset
The design of G18 handset comes as standard for all AWM-G2 series indoor which includes
• Real Time Timer
• Turbo Mode
• Personalized Setting Control
• Activation Of Negative Ion Generator
AMSD 1010/1015/1515/1020*/1520/2020* A/AR* Available in Cooling Only unit.
AMST 101010/101015/101515/101020*/101025*101525*/151520*/151525* A/AR* Available in Cooling Only unit
ACK 10/15/20 CACK 25 A
• Auto Fan Speed Control• Self Diagnosis System• Soft Dry Operation• Auto Random Restart
Multi Split SystemsAcson's Multi-Split Systems also include ACC-C and ACK-C as indoor coupling choices for cooling only models.
The aesthetically attractive unit is equipped with many advance features.• 24 Hours Real Time Timer• Sleep Mode Auto Control• Hydrophilic 'Slit' Fin• 3 Speed Fan Control
The reliable rotary compressor, which can efficiently providing an optimum cooling/heating capacity, is being used in the unit.
This fin design will enhance the heat transfer efficiency andthus boost up the cooling capacity.
Multi Split Systems
Ceiling Cassette
The ACK-E series is equipped with a newly-developed turbo fan; the shape produce low air turbulence.
With up to 4 selected fan speeds, users are given more choices. By selecting the Quiet mode, the sound pressure level can be as low as 27dBA.
E series
ALC 20/25/28 C/CR ALC 35/40/50 D/DR
ACK 20/25/28/40/50 E/ER
10 11
The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.
It is designed with unique “round” side contour and new LED light location. Rotateable intake grill promote uniform installation.
Combining 4 ways air discharge and large discharge area on each side, Ceiling Cassette promote even air distribution. The additional of the automatic air swing help further to evenly distribute conditioned air to every corner of the instrall area.
Allow 90°Rotation
The ACK-E series height is as low as 290mm to ease installation.
Select this setting to eliminate direct draftswhich can lead to discomfort.
55˚
75˚
55˚
75˚
Pattern 3Setting to Prevent Soiling of Ceiling Recommended for location with light colour
ceiling that must be kept spotless.
To increase the comfort level of the air conditioned area of ACK-E series, the system had been built in with 3 different type of air flow pattern to suit different requirement.
The default setting for air swing pattern is pattern 1. The air swing pattern can be selected through the wireless remote control.
Ceiling CassetteC series
The unit comes with a built-in high head drain pump 700mm head. A safety float is incorporated in the drain pump to monitor its water level.
700mm
Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required.
The slim panel can be blended easily into interior decoration and design.
It comes with 4 way air discharge and air swing function to ensure better air distribution and circulation in the room.
This intelligent feature helps to detect any faults or malfunctioning in the system and give user a warning by blinking of the LED lights.
12 13
Ceiling Cassette
The Ceiling Cassette C series is designed to be compact. Its body dimension is only 570mm X 570mm which can easily fit into a 600mm ceiling grids. This make installation a lot easier.
During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected.
The ACK-C series is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building.* Refer local representative for details.
NetWare IIIWired Controller
(Field Installed OptionalAccessories)
SLM 3Wired Controller
(Field Installed OptionalAccessories)
GS02
Ceiling ConvertibleE series
ACM 35/40/50 E/ER
ACM 15/20/25/28 E/ER
The ACM is designed with the option to install either below the ceiling or mounted at low wall position to suit any interior design requirement.
Wall bracket supplied as optional item
The unit is designed to work with high pressure head drain pump (optional). Thus offering flexibility for installation on condensate drain pipe. The drain pump comes with a high head and is incorporate with the float switch as safety protection.
700mm
Drain pump kit supplied as optional item
The washable filter can be easily access by just pulling down the intake grill. During servicing or repairing, only the bottom panel need to be remove in order to access.
The motorized louver enables the air flow to be evenly distributed. At the same time, negative ion will be released to provide quality air.
Ceiling ConvertibleNetWare III
Wired Controller(Field installed
optional accessories)
SLM 3Wired Controller(Field Installed
Optional Accessories)
GS02
ALC 18/20/25/28 C/CR
ALC 15 C/CR
ALC 30/35/40/50 D/DR
Power Failure Power Failure
E2 PROME2 PROM
Operation Stop Restart
Setting stored before power failure.
In the event of a sudden power failure during operation, unit can be automatically restarted in 64 different recovery timing patterns and the unit will operate base on the previous setting (Operating Mode, Temperature Setting and Fan Speed). This ensures that air conditioners in the same building resume randomly instead of all at the same time, preventing power surges after a blackout.
Equipped with two way air discharge, at front and bottom discharge; to provide better air distribution, for both cooling and heating effect.** Applicable for RCM 20-50 D/DR only.
Ceiling ConvertibleC&D series
RCM 62 C/CR (Ceiling Exposed only)
RCM 20/25/30/40/50 D/DR
The unit is designed with possibility to be installed under the ceiling or sitting on the floor to suit any interior design requirements.* Applicable for RCM 30-50 D/DR only.
The swing mode enables the air flow to be evenly distributed into the room from the front discharge area. ** Applicable for RCM 20-50 D/DR only.
16 17
The RCM range of product is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building.* Refer local representative for details.
Auto Mode allows the setting to change automatically between cool and heat mode depending on the room temperature and the set temperature required.
This feature helps to detect any faults or malfunctioning in the system and give user a warning by blinking of the LED lights.
Ceiling Convertible
Dust
The anti fungus air filter removes air-particles from the air.
During heat mode hot keep cycle, the fan will run at low speed during the thermostat cycle off. As a result, one will not feel the draft of cold air discharge from the unit. Option of fan stop or fan run at specific interval timing can also be selected.
SLM 3Wired Controller
(Field Installed OptionalAccessories)
NetWare IIIWired Controller(Field installed
optional accessories)
GS02
Power Failure Power Failure
E2 PROME2 PROM
Operation Stop Restart
Setting stored before power failure.
In the event of a sudden power failure during operation, unit can be automatically restarted in 64 different recovery timing patterns and the unit will operate base on the previous setting (Operating Mode, Temperature Setting and Fan Speed). This ensures that air conditioners in the same building resume randomly instead of all at the same time, preventing power surges after a blackout.
A LC 18/20/25/28 C/CR
ALC 30/35/40/50/61 D/DR
Ceiling ConcealedC series
The unit offers fan motor that can operate up to 4 speeds, thus provide choices of external static pressure for designing ducting system. In addition, a range of ACC-C model with optional specification of low external static pressure is also provided. Please refer to the technical specification of ACC-C model.
The microprocessor provides the possibility to detect and to diagnose any faults that occurs in the system. Faults are displayed as error code in the wired controller. This will ease the troubleshooting process.
Ceiling ConcealedThe ACC range of product is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a systems of multiple indoor units in a building.* Refer local representative for details.
Standard unit come with a simple and user friendly SLM 3. An optional specification of ACC-C series is also available that come with Netware III, which offers wide range of control features that includes 7 days and 24 hours timer settings, self diagnosis error code display and more.
NetWare III Controller(Optional)
SLM 3Wired Controller
Power Failure Power Failure
E2 PROME2 PROM
Operation Stop Restart
Setting stored before power failure.
In the event of a sudden power failure during operation, unit can be automatically restarted in 64 different recovery timing patterns and the unit will operate base on the previous setting (Operating Mode, Temperature Setting and Fan Speed). This ensures that air conditioners in the same building resume randomly instead of all at the same time, preventing power surges after a blackout.
The conditioned air can be distributed evenly to every corner of the room through ducting. This helps to create a pleasant environment and maintain comfort. Furthermore, multiple area can be conditioned simultaneously by using just one indoor units.
A set duct accessories specifically designed to fit and to suit the ACC-C model is being created. Thus offers a one stop solution to installing the unit.
The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan “built in” to the standard unit offers extra protection against possible water leaking problems.
Primary Drain PanPolysterene (Ps) With Height ImpactPolystyrene (Hips) Cover
Secondary Drain PanWith Insulation
Discharge Adaptor
Square GrilleAssembly c/w Adaptor
Secondary Drain Pan with Insulation
Primary Drain Pan
Square Return Grille Assembly
c/w Adaptor & Filter
FlexibleRound Duct(field supply)
Ceiling Concealed Unit ACC ReturnAssembly Bracket c/w Adaptor
FlexibleRound Duct(field supply)
* Available for ACC 10-25 C/CR only.
With ACC-E series, outdoor coupling no longer limited to AMC-D/ER series only. Different outdoor coupling had been tested with ACC-E series to give more choice on coupling selection.
Cater to different ducting application requirement, ACC-D and ACC-E series are designed with different static range. ACC-D series is designed for very high static requirement (up to 200pa), whereby ACC-E series is for high static requirement (up to 100pa). Both series offer 4 choices of external static pressure by using the built in four speeds direct drive fan motor. As such, selection of desire air flow or external static becomes much easier.
Ceiling ConcealedD&E series
AMC 75/100 D/ER
AMC 100 B/BR
Both ACC-D and E series offer lower height at 430mm only. Furthermore, depth of ACC-E series had even been reduced 44mm compared to ACC-D series. This gives ACC-E a more compact design. With this, the unit can be easily fitted into any concealed ceiling and allows more ceiling height space for interior design.
Both ACC-D and ACC-E series are designed to have better serviceability by allowing access to the internal components from side or bottom panel. The entire fan deck can be easily pulled in or out from either side of the unit to ease servicing of fan motor. Bottom access allows servicing of coil and other internal parts of the unit.
ACC-D series is supplied standard with Netware III wired which offers wide range of control features including 7 days programable timer , 24 hours timer setting, self diagnosis error code display and more.
ACC-E series is offered with SLM3 as standard. Advanced wired controller Netware III is offered as an option to provide wider range of control features.
Ceiling ConvertibleReturn ducting side
Supply ducting side
SLM 3Wired Controller
(Standard for ACC-E Series)
NetWare IIIController
(Standard for ACC-D Series)(Optional for ACC-E Series)
The designed of the direct drive condenser fans together with the raise fan guard helps to reduces the operating noise from the fan.Besides that, the compressor is well isolated to the housing cabinet, avoiding transmission of vibration. This also helps in reducing the sound pressure of the unit.
As the hot air density is lower than surrounding atmosphere, the vertical air throw of the Acson AVCU series have improved the air distribution. This in turn helps to improve the efficiency of the heat exchanger as well as avoid the hot air short circuit possibility for heat exchanger. The large coil surface area is incorporated with unique slit fins design and inner grove copper tube to increase the heat exchanger surface. This has helped to improve thermal transfer, providing maximum efficiency and hence boosts up the unit capacity.
VerticalCondensing Unit
Powder-coated fan guard and full metal louvered coil guard protect the condenser fan and the condenser coil, which forms part of the body of the AVCU, from damages by external forces. It also contributes largely to the appearance of the unit.
With a smaller base and the vertical air discharge, the Acson AVCU meets the requirement of minimum space utilization and suitable for multi-unit installation, especially in area whereby floor space constraint is an issue.
The AVCU is equipped with state-of-the-art compressor with proven quality, thus giving the unit high capacity, good performance, better reliability and durability. Besides that, the integration of a set of high and low pressure switches in the unit provides better protection to the compressor, prolonging the compressor life span.
The material used for the AVCU are designed to resist toughest climates. Constructed with gauge galvanized steel and powder paint, the strength of the structures have improved as well as giving better weather protection. This helps to establish AVCU series as a robust unit.
The Acson AVCU is capable to couple with various indoor units such as wall mounted, ceiling cassette, ceiling convertible and ceiling concealed split unit.
Vertical Condensing
Acson ducted split is offering very wide range of product lineup which is applicable from residential, to light commercial or even commercial use.
Ducted Split
• Expansion device: Thermal expansion valves are supplied as standard. Double TXV is used in heatpump model to optimize the performance for both cooling and heating.• Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration.• Indoor Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.• Condenser fan blade: Use of 32” and 36” propeller fan blade has effectively reduce the sound pressure level.• Condenser fan motor: IP20 for AMC 75/100 D/ER while IP54 for AMC 125/150 D/ER.
• High Pressure and Low Pressure protection. • Sensor fault indication. • Compressor & motor current overload protection.• Minimum compressor’s running time to ensure oil return.• Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation
Whenever unit stop due to power failure during operation unit automatically restarts at last setting condition once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Option is provided to cancel this feature.
AMC 150 CAMC 75/100/125/150 DAMC 75/100/125/150 ER
AMC 75/100 CAMC 75 CR
AMC 100/125 B/BR
AMC 200/250/300 D2
With only 4 different capacities outdoors, Acson ducted split product range is ranking up to an individual indoor unit at approximately 600MBH.
Either indoor or outdoor is coated with weatherproofed electro galvanized mild steel casing, with an epoxy is coated with an epoxy polyester powder costing for severe external conditions.Service Panel is available at the convenience side for both indoor and outdoor.
Convertible discharge air direction at indoor unit has made it versatile to various architectural designs.
Discharge line and suction line access valve is accessible without opening the unit casing.
Standard units are equipped with microprocessor controller and it is equipped with following functions:• Mode selection• Temperature Setting• Timer (delay timer for SLM3 and real timer for Sequential)• Error code display
Standard maximum piping length of Acson ducted split is up to 35m for Cooling Only model and 45m for heatpump model. However, long piping spec for Cooling Only model can be specified for stringent project requirement.
Fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam Insulation (CCF) has offered the following advantages:• Durable external surface that resists dirt tough and resilient• Higher degree of puncture resistance when compared to fiberglass• Easily cleaned surface (if necessary) to further resist microbial growth
The outdoor units are come with factory Nitrogen holding charge. Installer will need to charge the HCFC-22 (R-22) refrigerant at side according to the manual recommendation
Acson ducted split quality is ensured & qualified by specific testing method as following:• 100% coil leak test by helium testing method• Copper tubes were tested at burst pressure, where it is at least 3 times the refrigerant operating pressure.• Every components being used in our unit are tested, at factory test lab.• Every unit receives a 100% unit run test before leaving the production line to make sure it lives up to Acson requirement.
Ducted Split
Heatpump UnitADB 75/100/150/200/250/300/350/400/500 BRADB 125 CRADB 75/100/125/150/200/250/300/350/400/500/600 ER
Unit’s flat top design allows the unit to be stacked up at warehouse or even during transportation, resulting in maximum utilization of warehouse and container space.
Air-Cooled Rooftop
ART 60/80/100/120/150/200 A/AR
Acson rooftop is equipped with a solid base foundation and compact cabinet. The weatherproofed electro galvanized mild steel casing is coated with an epoxy polyester powder costing for protection against corrosion. Forklift slots and rigging hole is provide for better handling purpose. All Acson rooftop designs were rigorously rain tested at the factory to ensure the water integrity.
Acson rooftop quality is ensured & qualified by specific testing method as following:• 100% coil leak test by helium testing method• Copper tubes were tested at burst pressure, where it is at least 3 times the refrigerant operating pressure.• Every components being used in our rooftop are tested, at factory test lab.• Every unit receives a 100% unit run test before leaving the production line to make sure it lives up to Acson requirement.
Stackable
10mm thickness, fire-resistant Polyethylene is used at every possible condensate panel to prevent all forms of water or moisture penetration. Polyethylene, which is also a type of Closed Cell Foam Insulation (CCF) has offered the following advantages:• Durable external surface that resists dirt tough and resilient• Higher degree of puncture resistance when compared to fiberglass• Easily cleaned surface (if necessary) to further resist microbial growth
• The ART series are factory charged with HCFC-22 (R-22) refrigerant.
• Expansion device: Optimized capillary tube is used for better performance. However, thermal expansion valves spec can be specified in any project requirement.• Compressor: Each high efficiency scroll type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimize vibration.• Indoor Fan: A dynamically balanced forward curved fan with a field changeable pulley package, in order to match the designed supply air requirements.• Outdoor Fan: IP54 rated condenser fan is being used for ART 250/300/360/420 A/AR
• High Pressure and loss of refrigerant protection.• Compressor & motor current overload protection.• Sensor fault indication.• Minimum compressor’s running time to ensure oil return.• Phase sequencer is used to detect for any wrong phase and phase loss during installation and operation.
Whenever unit stop due to power failure during operation unit automatically restarts at last setting condition once the power is resumed. However, the compressors will restart randomly if more than one unit is installed and share the same phase of power. Option is provided to cancel this feature.
SLM 3 Controller Sequential Controller
• Standard units are equipped with microprocessor controller and every unit is come with a microprocessor operated handset, basic functions of these handset are: - Mode selection - Temperature Setting - Timer (delay timer for SLM3 and real timer for Sequential) - Error code display.
• Maximum point to point communication bus up to 1000m.• A single master unit can control up to 15 slave units in each group.• Support up to 128 air conditioning units on a single communication bus.• Each slave unit will sense their individual local temperature.
Network Interface Module (NIM) is a networking system which enables communication among Acson air conditioners.
With the Network Interface Module (NIM), all your air conditioning systems can be controlled with just a single controller giving you benefits:
• More convenience. No more individually controlling air conditioning units• Quicker and easier zone control from the master control unit• Better control of air conditioning systems operating conditionsNIM utilizes master-slave type system whereby the master node will issue commands to each of the slave nodes.
Every master unit will have a group address so that every slave can only response to their respective master. Each slave unit must have a unique address so that it can be addressed independently of other nodes.The master unit will be operating in conjunction with a control panel. Any settings
done via the control panel connected to the master will overwrite the settings of its slave units.Slave unit can be operated with or without control panel. If a slave unit is operating with a control panel, its settings can be changed without following its master.
• DIP switch setting for Group & Unit address.• Master or slave system configuration.• Automatic detection of control panel existence.• Error type and unit ID indication through• Display control panel.
• Main Board controller • Display control panel • NIM controller • Communications bus
MAINBOARD
MAINBOARD
CONTROLPANEL
CONTROLPANEL
NIM
NIM
MASTER 1
GROUP 1
Slave 1
MAINBOARD
MAINBOARD
CONTROLPANEL
CONTROLPANEL
NIM
NIM
MASTER 2
Slave 1 .......Slave 15
MAINBOARD
CONTROLPANEL
NIM
Slave 2 .......Slave 15
GROUP 2
MAINBOARD
MAINBOARD
CONTROLPANEL
CONTROLPANEL
NIM
NIM
MASTER N
Slave 1 .......Slave 15
GROUP N
NOTE:• Group address range from 1 to 128 (00000001-10000000) • Unit address range from 0 to 15 (0000-1111)
A 2-way twisted pair cable is used as the communication bus.Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.
First NIM to the furthestconnected NIMNIM to Main BoardNIM to Wired Controller
Recommended Maximum Cable Length (m)Connection
1000
1010
The communication bus must be connected serially to the adjacent NIM. (Daisy chair connection). The same polarity has to be connected between the NIMs (A to A, B to B).
28 29
S-NIM
• S-NIM controller• Communication Bus
The S-NIM system consists of• Main Board controller• Display control panel
Communication BusA 2-way twisted pair cable is used as the communication bus.Recommended cable for communication bus is a pair of screened & shielded, twisted single core wire with core diameter of 0.5mm to 1.0mm.
• Laboratory• Railway Switching Center• Room with Critical Electronics Equipments
Built on the NIM configuration, S-NIM serves to enhance the abilities and extend the operating lifetime of existing air conditioning units in harsh and demanding environment.S-NIM works in a master & slave system, operating at alternate sequence of preset hours. Whenever the operating unit is at fault, the standby unit will automatically takes over.Features• Auto restart feature with last state settings.• 2 air conditioning units in a master & slave system, operating at alternate sequence of preset time (3/4/5/7/9/11/12 hours).• System controlled by a single Netware 3 or SLM3 wired controller.• When the operating unit is at fault, the standby unit automatically takes over.• Error indication via error code displayed on LCD panel. (only is using Netware 3 control panel)• During system OFF mode, running timer will stop. It resumes when changing to ON mode.• Preset operation hours can be set via DIP Switch.* The air conditioning unit connected to the wired controller is always the master unit.
Master Unit Slave Unit
Typical connectionstructure for S-NIM
MainBoard
MainBoard
ControlPanel
S-NIMS-NIM
NIM must be used in conjunction with:• Main board Universal U1.4, W1V3 and above• Wired controller, Netware 3, SLM 3 or Wireless Remote Control
Netware 3SLM 3IR RemoteNone of the interface above
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) I) FOR AWM-J SERIES, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT. II) FOR AWM 301/301R, SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
MULTI- SPLIT AMST-A SERIES WITH WALL MOUNTED
Btu/h
W
50 Hz W
V/Ph/Hz
l/s / cfm
l/s / cfm
l/s / cfm
dBA
mm/in
mm/in
mm/in
kg/lb
dBA
mm/in
mm/in
mm/in
kg/lb
LIQUID mm/in
GAS mm/in
IND
OO
R U
NIT
NOMINAL CAPACITY
NOMINAL TOTAL INPUT POWER
OUTDOOR UNIT
INDOOR UNIT
COOLING ONLYMODEL
HIGH
POWER SOURCE
PIPE CONNECTION
WIDTH
DEPTH
SIZE
UNITDIMENSION
UNIT WEIGHT
UNITDIMENSION
HEIGHT
OU
TD
OO
R U
NIT
UNIT WEIGHT
WIDTH
TYPE
HEIGHT
DEPTH
SOUND PRESSURE LEVEL
MEDIUM
SOUND PRESSURE LEVEL (H/M/L)
LOW
AIR FLOW
2 x AWM 10G AWM 25G AWM 10G AWM 15G AWM 25G 2 x AWM 15G AWM 20G 2 x AWM 15G AWM 25G
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELOW THE UNIT.
GAS mm/in 9.52 / 3/8 15.88 / 5/8 12.70 / 1/2 15.88 / 5/8 2 x 15.88 / 2 x 5/8
SOUND PRESSURE LEVEL
212 / 450
NOMINAL TOTAL INPUT POWER
DIMENSION ( )-PANEL
220 - 240 / 1 / 50
FAN AIR FLOW
SOUND PRESSURE LEVEL 47 / 46 /44
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
250 (295) / 9.8 (11.6)
631.7 / 24.9
5280
3112 3421
18000
23 + 2
4628
AMSD 1020A AMSD 1520A AMSD 2020A
2 x 6.35 / 2 x 1/4
95 / 209.4 100 / 220.5 106 / 233.7
FLARE VALVE
2 x 6.35 / 2 x 1/4
960 / 37.8
POWER SOURCE
IND
OO
R U
NIT
WEIGHT (UNIT+PANEL)
OU
TD
OO
R U
NIT UNIT DIMENSION
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
NOMINAL COOLING CAPACITY
INDOOR UNITCOOLING ONLY MODEL
OUTDOOR UNIT
S5
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE EASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
MULTI-SPLIT AMST-A SERIES WITH CEILING CASSETTE
MULTI-SPLIT AMST-A SERIES WITH CEILING CASSETTE
Btu/h
W
50 H
Z
W
V/Ph/Hz
l/s / cfm
dBA
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg
dBA
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg / lb
LIQUID mm/in
GAS mm/in
NOMINAL TOTAL INPUT POWER
UNIT WEIGHT
TYPEPIPECONNECTION
COOLING ONLYMODEL
OUTDOOR UNIT
INDOOR UNIT
DIMENSION
( )-PANEL
POWER SOURCE
IND
OO
R U
NIT
FAN AIR FLOW ( HIGH )
NOMINAL COOLING CAPACITY
UNIT DIMENSION
OU
TD
OO
R U
NIT
SOUND PRESSURE LEVEL
SIZE
WEIGHT (UNIT+PANEL)
SOUND PRESSURE LEVEL (H/M/L)
AMST 101010A AMST 151515A
3 x ACK 10C 2 x ACK 10C ACK 15C ACK 10C 2 x ACK 15C 3 x ACK 15C 2 x ACK 10C ACK 20C
2 x 6.35 / 2 x 1/4 9.52 / 3/8 2 x 6.35 / 2 x 1/4 9.52 / 3/8 2 x 6.35 / 2 x 1/4 9.52 / 3/8
2 x 9.52 / 2 x 3/8 15.88 / 5/8 9.52 / 3/8 12.70 / 1/2 15.88 / 5/8 2 x 12.70 / 2 x 1/2 15.88 / 5/8
12300 ( 2780 - 12300)
42000 ( 9500 - 42000) 44500 ( 9500 - 44500)
AMST 101025A AMST 101525A
13040 ( 2780 - 13040)
AMST 151525A
47000 (12000-47000)
FLARE VALVE
4938 ( 1154 - 4938)
117 / 257.9 120 / 264.6 123 / 271.2
5444 (1660-5444)
71 7171
4416 ( 1146 - 4416)
220 - 240 / 1 / 50
850 / 33.46
1030 / 40.5
400 / 15.75
13775 (3517-13775)
570 (640) / 22.4 (25.2)
570 (640) / 22.4 (25.2)
S6
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW THE CENTER OF THE UNIT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW THE CENTER OF THE UNIT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.
MULTI-SPLIT AMST-A SERIES WITH CEILING CONCEALED
MULTI-SPLIT AMST-A SERIES WITH CEILING CONCEALED
Btu/h
W
50 HZ W
POWER SOURCE V/Ph/Hz
HIGH cfm / L/s
MEDIUM cfm / L/s
LOW cfm / L/s
STATIC PRESSURE H/M/L mm Aq (Pa)
HIGH cfm / L/s
MEDIUM cfm / L/s
LOW cfm / L/s
STATIC PRESSURE H/M/L mm Aq (Pa)
dBA
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg / lb
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg / lb
dBA
LIQUID mm/in
GAS mm/in
SOUND PRESSURE LEVEL ( H/M/L )
DIMENSION
WEIGHT
INDOOR UNIT
NOMINAL COOLING CAPACITY
COOLING ONLY MODELOUTDOOR UNIT
IND
OO
R U
NIT
AIRFLOW
NOMINAL TOTAL INPUT POWER
STD STATICAIRFLOW
LOW STATIC
OU
TD
OO
R U
NIT
WEIGHT
TYPE
SIZE
PIPECONNECTION
DIMENSION
SOUND PRESSURE LEVEL
AMST 101010A AMST 151515A
3 x ACC 10C 2 x ACC 10C ACC 15C ACC 10C 2 x ACC 15C 3 x ACC 15C 2 x ACC 10C ACC 20C
2 x 6.35 / 2 x 1/4 9.52 / 3/8 2 x 6.35 / 2x 1/4 9.52 / 3/8 2 x 6.35 / 2 x 1/4 9.52 / 3/8
2 x 9.52 / 2 x 3/8 15.88 / 5/8 9.52 / 3/8 12.7 / 1/2 15.88 / 5/8 2 x 12.7 / 2 x 1/2 15.88 / 5/8
AMST 101025A AMST 101525A
12300 (2780 - 12300)
AMST 151525A
220 - 240 / 1 / 50
13040 ( 2780 - 13040) 13780 ( 3520 - 13780)
47000 ( 12000 - 47000)34900 ( 9500- 34900)
5004 5531
42000 ( 9500 - 42000)
1030 / 40.55
4461
850 / 33.46
FLARE VALVE
71
123 / 271.2
7171
120 / 264.6
400 / 15.75
117 / 257.9
28500 ( 9500 - 28500)
S8
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) I) FOR ACK 20/25 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA. II) FOR ACK 28/40/50 E/ER, SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW FASCIA.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW FASCIA.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 1m BELOW THE UNIT.
CEILING CONVERTIBLE RCM-C & D SERIESRCM 50DR RCM 62CR
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVELS ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELOW THE CENTER OF THE UNIT. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151.3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. TESTED WITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET.5) EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
CEILING CONCEALED ACC-C SERIES
S14
CEILING CONCEALED ACC-D SERIES (VERY HIGH STATIC)ACC 75DR ACC 100DR
AMC 75ER AMC 100ER
Btu/h 75000 100000
W 21960 29310
Btu/h 84000 110000
W 24600 32240
NOMINAL TOTAL INPUT POWER COOLING W 7356 10200
NOMINAL TOTAL INPUT POWER HEATING W 7206 9800
W/W 3.14 3.01
W/W 3.59 3.46
ACC 75D ACC 100D
AMC 75D AMC 100D
Btu/h 75000 100000
W 21960 29310
W 7356 10200
W/W 3.14 3.01
V/Ph/Hz
l/s / CFM 1142 / 2420 1487 / 3150
l/s / CFM 1156 / 2450 1477 / 3130
l/s / CFM 944 / 2000 1340 / 2840
l/s / CFM 793 / 1680 1057 / 2240
Pa (in.wg.)
dBA 52 / 52 / 48 / 43 55 / 54 / 52 / 48
mm/in 430 / 16.9 430 / 16.9
mm/in 1370 / 53.9 1655 / 65.2
mm/in 826 / 32.5 826 / 32.5
kg/lb 92 / 203 119 / 262
dBA
mm/in
mm/in
mm/in
kg/lb 170 / 374 184 / 405
LIQUID mm/in 12.70 / 1/2 15.88 / 5/8
GAS mm/in 25.40 / 1 25.57 / 1-1/8
50 H
z
NOMINAL TOTAL INPUT POWER
50 H
z
SUPER HIGH
HEIGHT
HEIGHT
EER
MEDIUM
EXTERNAL STATIC PRESSURE (SH/H/M/L)
NOMINAL HEATING CAPACITY
INDOOR UNIT
HEAT PUMP MODELOUTDOOR UNIT
POWER SOURCE
INDOOR UNIT
NOMINAL COOLING CAPACITY
EER
COP
OUTDOOR UNITCOOLING ONLY MODEL
NOMINAL CAPACITY
SOUND PRESSURE LEVEL (SH/H/M/L)
196 / 137 / 98 / 69 (0.79 / 0.55 / 0.39 / 0.28)
380 - 415 / 3 / 50
64
HIGH
IND
OO
R U
NIT
UNIT WEIGHT
DEPTH
WIDTH
OU
TD
OO
R U
NIT
SOUND PRESSURE LEVEL
UNIT DIMENSION
UNIT DIMENSION WIDTH
AIR FLOW
LOW
DEPTH
1041 / 41.0
981 / 38.6
981 / 38.6
BRAZING
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. MICROPHONE POSITION : a) INDOOR UNIT : 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM). b) OUTDOOR UNIT : LOGARITHMIC MEAN OF MEASUREMENT AT 1m AWAY FROM EVERY SIDE OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
CEILING CONCEALED ACC-E SERIES (HIGH STATIC)
ACC 75ER ACC 100ER
AMC 75CR AMC 100BR
Btu/h 75000 95000
W 21960 27840
Btu/h 76000 100000
W 22270 29310
NOMINAL TOTAL INPUT POWER COOLING W
NOMINAL TOTAL INPUT POWER HEATING W
W/W 2.64 2.55
W/W 3.21 3.35
ACC 75E ACC 100ER
AMC 75C AMC 100B
Btu/h 75000 100000
W 21960 29310
W
W/W 2.47 2.50
V/Ph/Hz
l/s / CFM 1182 / 2500 1513 / 3200
Pa / in.wg 100 / 0.4 100 / 0.4
dBA 54 57
mm/in 430 / 16.9 430 / 16.9
mm/in 1372 / 54.0 1600 / 63.0
mm/in 784 / 30.9 784 / 30.9
kg/lb 92 / 202.8 119 / 262.4
dBA 74 65
mm/in 946 / 37.2 946 / 37.2
mm/in 1300 / 51.2 939 / 37.0
mm/in 500 / 19.7 1116 / 43.9
kg/lb 145 / 319.7 164 / 361.6
LIQUID mm/in 12.70 / 1/2 15.88 / 5/8
GAS mm/in 25.40 / 1 25.57 / 1-1/8
UNIT WEIGHT
SOUND PRESSURE LEVEL
UNIT DIMENSION
HEIGHT
WIDTH
DEPTH
PIPE CONNECTION
TYPE
SIZE
COOLING ONLY MODELINDOOR UNIT
OUTDOOR UNIT
DEPTH
UNIT WEIGHT
AIR FLOW (HIGH)
OU
TD
OO
R U
NIT
50 H
zIN
DO
OR
UN
IT EXTERNAL STATIC PRESSURE (HIGH)
SOUND PRESSURE LEVEL (HIGH)
UNIT DIMENSION
HEIGHT
WIDTH
NOMINAL CAPACITY
POWER SOURCE
COP
NOMINAL COOLING CAPACITY
50 H
z NOMINAL TOTAL INPUT POWER
EER
NOMINAL HEATING CAPACITY
EER
HEAT PUMP MODELINDOOR UNIT
OUTDOOR UNIT
380 - 415 / 3 / 50
BRAZING
Not Available
Not Available
VERTICAL CONDENSING UNIT AVCU-A SERIES
~ EER/COP CALCULATION IS BASED ON EFFECTIVE POWER INPUT AS PER ISO 5151.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151: 1994(E)3) NOMINAL COOLING CAPACITY IS BASED ON THE CONDITIONS BELOW : a) COOLING - 27.0°C DB / 19.0°C WB INDOOR AND 35°C DB OUTDOOR
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. MICROPHONE POSITION : a) INDOOR UNIT : 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM). b) OUTDOOR UNIT : LOGARITHMIC MEAN OF MEASUREMENT AT 1m AWAY FROM EVERY SIDE OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. MICROPHONE POSITION : a) INDOOR UNIT : 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM). b) OUTDOOR UNIT : LOGARITHMIC MEAN OF MEASUREMENT AT 1m AWAY FROM EVERY SIDE OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
DUCTED SPLIT ADB-B SERIES
DUCTED SPLIT ADB-B SERIES
ADB 450B3 ADB 500B4 ADB 600B4 ADB 750B5
AMC 150C x 3 AMC 125B x 4 AMC 150C x 4 AMC 150C x 5
AMC 100B x 1 AMC 125B x 2 AMC 100B x 4 AMC 100C x 4
Btu/h 400000 400000
W 117200 117200
50HZ W 41635 41075
V/Ph/Hz
l/s / cfm
Pa / in.wg
dBA
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg/lb
dBA 65 65 65 76
HEIGHT mm/in 946 / 37.24 971.4 / 38.24
WIDTH mm/in 1116 / 43.93 1393 / 54.84
DEPTH mm/in 939 / 36.96 500 / 19.68
kg/lb 164 / 361 169 / 372 164 / 361 178 / 392
LIQUID mm/in
GAS mm/in
UNIT WEIGHT
PIPE CONNECTION
TYPE
SIZE
SOUND PRESSURE LEVEL
UNIT DIMENSION
OU
TD
OO
R U
NIT
946 / 37.24
1116 / 43.93
939 / 36.96
BRAZING
1466 / 57.71
UNIT WEIGHT
UNIT DIMENSION
1546 / 60.86 1546 / 60.86
2122 / 83.54
1199 / 47.20
2274 / 89.52
513 / 1131440 / 970
POWER SOURCE 380~415 / 3 / 50
SOUND PRESSURE LEVEL 66 66
356.7 / 1.43
ADB 400B4
OUTDOOR UNIT
IND
OO
R U
NIT
AIR FLOW (HIGH) 4956 / 10500 5664 / 12000
EXTERNAL STATIC PRESSURE (HIGH) 200 / 0.8
NOMINAL TOTAL INPUT POWER
COOLING ONLY MODELINDOOR UNIT ADB 350B3
35486
NOMINAL CAPACITY350000
102550
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. MICROPHONE POSITION : a) INDOOR UNIT : 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM). b) OUTDOOR UNIT : LOGARITHMIC MEAN OF MEASUREMENT AT 1m AWAY FROM EVERY SIDE OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
DUCTED SPLIT ADB-D SERIES
DUCTED SPLIT ADB-D SERIES
ADB 150D1 ADB 150D2
AMC 150D AMC 75D x 2 AMC 100D x 2 AMC 200D2 AMC 125D x 2 AMC 250D2
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. MICROPHONE POSITION : a) INDOOR UNIT : 1.4m BELOW THE UNIT (FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM). b) OUTDOOR UNIT : LOGARITHMIC MEAN OF MEASUREMENT AT 1m AWAY FROM EVERY SIDE OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL. 5) EFFECTIVE POWER INPUT IS USED IN THE RATED EER CALCULATION, ACCORDING TO ISO STANDARD: ISO 5151 & ISO 13253
NOMINAL TOTAL INPUT POWER (HEATING) 7570 8819 9613
EER (COOLING) 2.50 2.72 3.09
NOMINAL TOTAL INPUT POWER (COOLING) 9300 10829 11484
NOMINAL HEATING CAPACITY75000 100000 116300
21981 29308 34090
NOMINAL COOLING CAPACITY73000 94000 111900
21400 27550 32800
ADB 125ER
OUTDOOR UNIT AMC 75FR AMC 100FR AMC 125FRMODEL
INDOOR UNIT ADB 75ER ADB 100ER
OUTDOOR UNIT AMC 75F AMC 100FMODEL
INDOOR UNIT ADB 75D ADB 125D
AMC 125F
NOMINAL CAPACITY75000 98000 113500
21980 28720 33260
ADB 100D
NOMINAL TOTAL INPUT POWER 9120 10,620 11087
EER (COOLING) 2.63 2.89 3.26
S20
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8615 STANDARD. I) FOR ADB150BR AND BELOW, POSITION OF THE MEASUREMENT POINT IS 1.4m BELOW THE UNIT. TESTED WITH FREE RETURN INLET AND 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET. II) FOR ADB200BR AND ABOVE, POSITION OF THE MEASUREMENT POINT IS 1m AWAY FROM THE SERVICE PANEL AND 1m HEIGHT FROM THE FLOOR LEVEL. TESTED WITH FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM.
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER.: POSITION OF THE MEASUREMENT POINT IS 1m AWAY FROM THE SERVICE PANEL AND 1m HEIGHT FROM THE FLOOR LEVEL. TESTED WITH FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM.
OUTDOOR UNIT AMC 100ER x 2 AMC 125ER x 2 AMC 150ER x 2 AMC 100ER x 3
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER.: POSITION OF THE MEASUREMENT POINT IS 1m AWAY FROM THE SERVICE PANEL AND 1m HEIGHT FROM THE FLOOR LEVEL. TESTED WITH FREE RETURN AND THE DISCHARGE AIR WAS DUCTED TO ADJACENT ROOM.
OUTDOOR UNIT AMC 100ER x 4 AMC 150ER x 3 AMC 125ER x 4
464000450000
S23
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW : a) COOLING - 27°C DB / 19°C WB INDOOR AND 35°C DB / 24°C WB OUTDOOR b) HEATING - 20°C DB INDOOR AND 7°C DB / 6°C WB OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8615 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT OF THE UNIT AND 1m ABOVE THE FLOOR LEVEL.