Air Conditioning Light Commercial, Commercial and Industrial June 2018 Air Conditioning
The new airport in Istanbul is the largest infrastructure project in Turkey. When completed, it will become the largest newly constructed airport in the world.The runways from which flights will depart for over 350 destinations will be 3,750 meters long and 60 meters wide.The project calls for four stages of construction, the first scheduled for completion in 2018.Systemair has been chosen as a supplier thanks to its efficiency, quality and the design of its products, the high quality standards of its international production and overall trust in the brand. 531 air handling units and more than 5,000 hydronic terminals will be installed in the airport.
Italy has contributed to the design of this airport!The control tower, winner of Chicago Athenaeum’s 2016 International Architecture Award, was designed by the renowned Italian architect Pininfarina. The finished tower will overlook an area of 6,085 sq.m from its height of 90 meters. The tower’s shape is inspired by the tulip, the symbol of Istanbul for many centuries and an important cultural icon in Turkey’s history.
New airport in Istanbul - Turkey
Front image: Istanbul airport
1
Systemair Worldwide 2
Systemair product range 4
Systemair Application 6
Systemair online 8
Systemair Air Conditioning 10
Air Cooled Chiller and Heat Pump 14
Water Cooled Chiller and Heat Pump 89
Free-Cooling 107
Condensing unit 111
Residential Heat Pump 130
Water Terminals 140
Water Source Heat Pump 166
Rooftop 176
Close control 184
Direct expansion 193
HPT Hydrokit 198
The 36,000 square meters of the headquarters in Skinnskatteberg, Sweden and the 450 professionals who work there are just part of what today has become Systemair. Founded by Gerald Engstrom in 1974, today the company is present in 50 countries on 5 continents with manufacturing locations around the world, and is recognized as a key player in the HVAC industry.Systemair:• More than 40 years of history.• Founded in 1974 by Gerald Engstrom, current Chairman of the
Management Board of the Systemair Group.• Turnover in continuous growth. €650 million in sales in the 2015
2016 fiscal year.• 15% average annual sales growth over the past 10 years.
• Direct presence of company-owned subsidiaries in 50 countries in Europe, North and South America, Middle East, Asia and South Africa.
• 24 factories with more than 280,000 sq.m of production space.• 66 companies with more than 4,800 employees.• The highest credit rating (AAA).• Listed on the NASDAQ OMX Nordic Exchange.These are the results that allow us to look with confidence towards the challenges of the future. In Sweden, Italy and the World.
From Sweden to the World: the numbers of a company in constant growth
Contents
Contents |
2
Skinnskatteberg, SwedenThe Group headquarters, distribution center and largest production site. Production of compact air handling units, a wide range of fans and accessories, air curtains and fan heaters. Hässleholm, Sweden Production of heating products for air handling units, fan heaters and dehumidifiers. Windischbuch, Germany Production facility and distribution center, specializing in engineered products. Langenfeld, Germany Production of air curtains.
Mühlheim an der Ruhr, GermanyProduction of air handling units for swimming pool halls and comfort ventilation. Ukmergé, Lithuania Production of residential units and large air handling units. Maribor, Slovenia Production of high-temperature fans for smoke extract ventilation. Aarhus, Denmark Production of large air handling units. Bratislava, Slovakia Production of air distribution products and fire dampers.
Hyderabad, India Production of air distribution products. Greater Noida, New Delhi, India Production of duct, axial and box fans, air handling units and air distribution products. Kuala Lumpur, Malaysia Production of duct and axial fans. Johannesburg, South Africa Production of axial fans. Lenexa, USA Manufacturing and distribution center of ventilation products.
| Systemair worldwide
Systemair worldwide
3
Our commitment to quality Systemair is certified in accordance with ISO 9001, ISO 14001, ATEX and European fire safety standard EN 12101-3. Our research and development laboratories are among the most modern in Europe. Our measurements are made in accordance with international standards such as AMCA and ISO.
Save energy and lower running costs! Our “Green Ventilation” label highlights products that combine energy economy with energy efficiency, offering end users high energy-saving potential. The ErP symbol indicates that the product fulfills EU demands on energy consumption.
Barlassina, Italy Production of liquid and air-cooled chillers and heat pumps for comfort cooling. Tilliéres, France Production of air conditioning products for the commercial market. Madrid, Spain Production of large air handling units and box fans. Bouctouche, Canada Production of air handling units. Tillsonburg, Canada Production of air handling units.
Eidsvoll, Norway Production of air handling units. Istanbul, Turkey Production of air handling units and fan coils. Waalwijk, The Netherlands Production of air handling units. Pardubice, Czech Rep. Development and manufacturing of air handling units and air curtains. Winterbach, Germany Development and production of air curtains.
Helmstadt, Germany Manufacturing of rotary heat exchangers. Sao Paolo, Brasil Manufacturing of air handling units and accessories. Wujiang, China Production of air handling units.
Always close to you!
3 Distribution Centers 27
Production Facilities50 Countries with Sales Subsidiaries
Systemair worldwide |
4
Duct fansDuct fans for circular duct installation.
Roof fans Roof fans with circular or square con-nection.
Rectangular duct fansDuct fans with rectangular connec-tion.
Centrifugal fansCentrifugal supply single fans.
Axial fansAxial fans for duct or wall application.
Square duct fansFor different applications, there are models for ambient with high tem-perature.
Jet Axial FansJet Axial Fans for car park, tunnels and air overpression.
Fans
Systemair has the wider range of fans for use in different applications.Our range includes any type of fans, from circular ducts – hystorical product – boxed up to those of extraction, axial, and explosion-proof for the extraction of fumes. All products listed above are made in different dimensions from 100 mm in diameter to fans of large size for tunnel. All our fans are designed to meet the strict requirements, easy to use, high quality and durability.
Product range
Explosion proof fansExplosion proof fans in duct, roof or wall design.
High temperature fansSystemair provides high fire resis-tance fans till 600°C/2 hours.
Systemair has an extensive range of ventilation products: fans including smoke extractor, tunnel and car park fans, explosion proof fans, air handling units from large central units to small residential units with energy recovery, air distribution products and fire dampers. These products are installed in a variety of locations, including homes, offices, healthcare premises, shops, industrial buildings, tunnels, parking garages, training facilities, sport centres etc.
| Systemair Product range
5
Air distribution products
The range also includes a wideselection of air distribution productsand accessories.
Nozzle diffusersOptimum flexibility and comfort in airdistribution for rooms.
Supply, extract & transfer devicesFor mounting in ceilings or walls.
Residential ventilation
Complete energy-efficient air han-dling units with heat recovery and built in control systems. Designed to be mounted over the cooker, on walls or horizontally in attics.
Residential unitsFor homes with living areas of 60-320 m2.
Cooker hoodsIdeal for capturing odours even at low airflows.
Fire safety Smoke extract fansHigh efficient fans to extract the combustion smoke.
Fire & smoke dampersDampers that reduce the spread ofsmoke and fire.
Air handling unitsSystemair produces a wide range of air handling units for several ap-plications, from small office to large industrial building. All range is been developed to satisfy strict needs of low energy consumption.
Systemair Product range |
6
Systemair – an importantpart of everyday life
AIR HANDLING UNITSCompact and modular units for use in industry, commerce, schools, hospitals and so on.
AIR CURTAINS AND HEATING PRODUCTS Air curtains, fan heaters and radiant heaters are marketed under the Frico brand.
AIR CONDITIONING Liquid and air-cooled air conditioning products, together with heat pumps for comfort and industrial cooling.
FANS AND ACCESSORIES Products such as circular and rectangular duct fans, roof fans, box fans and axial fans.
Systemair products and systems are all around us, provid-ing a comfortable and healthy indoor climate across a wide variety of application areas - from homes and workplaces to public buildings, shopping centers and transportation infrastructures.
| Systemair application
7
SWIMMING POOL VENTILATIONExtra high-efficiency ventilation units for indoor swimming pools and other environments with very high air humidity.
AIR DISTRIBUTIONProducts for air distribution, including supply and exhaust diffusers, dampers and grilles.
TUNNEL VENTILATIONFans and systems for ventilation of all types of tunnels for roads, rail and metro systems.
CAR PARK VENTILATIONComprehensive system solu-tions for multi-storey or under-ground car parks and fire/smoke applications.
RESIDENTIAL VENTILATIONSmall ventilation units for apart-ment buildings and single-family homes, mostly including heat recovery.
FIRE SAFETYProducts that have been tested and certified to withstand high temperatures for a long period.
Systemair application |
8
We offer a wide range of tools online to assist in choosing the product or system best suited to your specific needs.All our documentation can be freely viewed online or downloaded without login or password.
Systemair online: The world of Systemair is just a click away
Thanks to the "Systemair Media Center" app, all our documentation is always available on your smartphone or tablet.
• Everywhere: on site, when travelling, in the office• Always available, even offline• Constantly updated
Systemair Media Center: Systemair app!
NEW!
| Systemair online
Download Systemair Media Center app
9
Catalogues and BrochuresOur documentation library has more than 80 manuals including technical catalogues and leaflets, always viewable online or downloadable for offline reference.
Product DocumentationComplete documentation for each Systemair product is available online: technical data sheets, CAD blocks, user and maintenance manuals, electrical connections, certifications, CE declarations, DoP declarations and so on.
Technical catalogue onlineThe Systemair catalogue is also available online. The intuitive structure of the content makes it easy to find and select the product needed.
BIM supportBIM is the new frontier of integrated design. Models from Systemair's MagiCloud library can be downloaded in DXF format for CAD software or RFA format for REVIT.
Selection softwareSee our extensive range of selection software for ventilation, air diffusion, heating and air conditioning. It is possible to download the programs from a dedicated area in our website.
Online selection programA reliable and simple online selection program thanks to continuous updates and user friendly interface. The "Product Selector" is available online for PC, tablet and smartphone use.
Systemair online |
10
France - Tillières-sur-Avre
| Systemair Air Conditioning
RangeThe factory develops and manufactures a wide range of air conditioning products: Chillers & Heat Pumps Water Terminals Residential Heat Pumps Water Source Heat Pumps Roof Top Direct expansion.
Our sales department will be able to design THE solutions that fit your needs.The factory benefits from ISO 9001 certifications.Besides, Systemair AC participates in the Eurovent certification programme insuring, by independent laboratories, the check of the technical specifications according to the international standards.
Production The factory in France, extends over a total area of 37.000 sqm with 200 employees.
The companySystemair AC, the French factory of Syste-mair group, founded in 1947 by Paul Vallet, is one of the globally leading manufacturer and distributor of air conditioning systems.More than 60 years of experience in design, development and production of residential, commercial and industrial applications make Systemair a key player on the european market. References are numerous in France and internationally, and concern all lines of business including many hospitals (surgery rooms, white rooms...), industrial sites, energy-efficientoffice buildings, hotels ...
11
Italy - Barlassina
Systemair Air Conditioning |
RangeThe factory develops and manufactures a wide range of air conditioning products: Chillers & Heat Pumps Condensing Unit.
The range of product, that is Eurovent certi-fied, consists of Air and Water cooled chillers and heat pumps as well as condensing and condenserless unit.
Production The factory in Italy extends over a total area of 33.400 sqm and a manufacture area over of 19.400 sqm with around 200 employees.
The companySystemair, Italian factory of Systemair Group, is important in equipment for HVAC’s market from 20 to 1.700 kW suit-able for a wide range of applications of air conditioning and industrial processes.Systemair has 70 years experience in the industrial production, of which 50 years in HVAC business.Systemair Italy is equipped with high tech equipment and has one of the most mod-ern research centers in Europe for the de-velopment and testing of chillers and heat pumps.
12
Applications
OfficesIn buildings for tertiary application, the air conditioning and the ventilation are nec-essary during the day. The heat loads to be removed are generally generated by people present, from the lighting system, from solar radiation and by machines.Normally it is necessary the use of chillers, Heat Pump to produce cold and/or hot water to be sent to hydronic (fan coils, cassettes, ducted) to obtain an optimum air conditioning of offices.
SchoolsIn buildings for school, the load to be disposed is variable during the day due to the presence of people only for some periods, thus it is mandatory to control the users requirements during daily plant use. Systemair offers a wide range of equipment suitable for this purpose, the fan coils with EC motors allow to obtain the requiredflexibility.
13
Commercial buildingsNormally the number of people varies continuously; the optimal solution would be to use machinery for the conditioning with variable flow and with constant moni-toring of concentration of pollutants (VOC and CO2). Systemair ACʼs products can easily meet the plantʼs requirement.
IndustryIndustrial plants generate a large amount of heat that must be dissipated in the appropriate way.Systemair AC offers a wide range of products (chillers from 20 kW to 1.700 kW) that can be readily integrated industrial installation. The chiller can be used both for air conditioning and for the cooling equipment process (production of chilled water up to -10°C).
HotelsIn the hotel rooms, it is needed a high level of comfort with the minimum impact with respect to the noise level. Systemair ducted products equipped with EC motors fully comply with requirements efficiency, cooling capacity and sound impact , required by this type of installations.
| Air cooled Chiller & Heat Pump14
Air Cooled Chiller & Heat Pump
VLS/VLH604-1204 153-307 kW 170-337 kW R410A Scroll PlatePages 38 and 76
AQVL/AQVH 85-140 83-137 kW 87-144 kW R410A Scroll PlatePages 34 and 70
SyScroll 85-135 Air CO-HP 84-132 kW 85-133 kW R410A Scroll PlatePages 32 and 68
SyScroll 20-35 Air CO 21-34 kW R410A Scroll Plate Page 24
SyScroll 40-75 Air CO-HP 41-77 kW 39-76 kW R410A Scroll PlatePages 28 and 64
SysAqua 20-40L-H 19-39 kW 20-42 kW R410A Scroll PlatePages 26 and 62
SysAqua 45-125 L-H 47-128 kW 48,5-119 kW R410A Scroll PlatePages 30 and 66
SyScroll 20-30 Air EVO HP 20-36 kW 20-34 kW R410A Scroll Inverter PlatePage 60
Mini SysAqua DCI 5-16 5-14,5 kW 6,2-16 kW R410A Rotary Inverter PlatePage 58
SysAqua 140-210 L-H 125,4-209 kW 143,7-217,6 kW R410A Scroll PlatePages 36 and 74
ErP2018ErP
20182017
ErP2018
ErP2018
ErP20182017
ErP20182017
ErP2018
SysCloud
SysCloudSysCloud
ErP20182017
ErP20182017
ErP20182017
ErP20182021
2021Ready.
ErP20182021
2021Ready.
ErP20182021
2021Ready.
ErP20182017
ErP2018
ErP20182017
ErP2018
ErP20182017
ErP20182021
2021Ready.
ErP20182021
2021Ready.
ErP20182021
2021Ready.
ErP2018
Air cooled Chiller & Heat Pump | 15
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SyScrew 300-1400 Air CO 295-1.395 kW R134a Screw Shell & TubePage 54
SyScrew 370-1250 Air EVO CO 360-1.250 kW R134a R513A Screw Shell & TubePage 48
SyScroll 240-660 Air CO-HP 238-654 kW 256-679 kW R410A Scroll PlatePages 46 and 86
SyScroll 140-360 Air EVO CO-HP 144-361 kW 145-361 kW R410A Scroll PlatePages 42 and 80
SyScroll 400-900Air EVO CO-HP 399-897 kW 404-902 kW R410A Scroll PlatePages 44 and 84
ErP2018
Low-temperature Heat Pumps Minimum ηsh to be Ecodesign compliantCOMMISSION REGULATION (EU) No813/2013
Air to Water Comfort chillers <400kW Minimum ηsc to be Ecodesign compliantCOMMISSION REGULATION (EU) No2016/2281
EcodesignLow-temperature Heat Pumps / Air to Water Comfort chillers <400kW
ErP2018
The operating parameters of your unit(s) at anytime, from anywhere !
Among many different functionalities, this new user friendly connected tool allows you, for example, to see all your unit(s)’ operating data, change and store settings, get
alarm notifications and make remote diagnostics.
Don’t lose time and money anymore going on site. Just login and Click !
NEWSysCloud
Available with SysAqua units
100
110
120
130
140
150
160
170
2015 2016 2017 2018 2019 2020 2021 2022
ηsc / ηsh
149
161
115
125
Sept. 2015
Sept. 2017
Jan. 2018
Jan. 2021
years
ErP2018
ErP20182017
ErP2018
ErP20182017
ErP2018
ErP20182017
ErP20182021
2021Ready.
ErP20182021
2021Ready.
| Air cooled Chiller & Heat Pump16
Selecting guide Air Cooled Chiller
Product Family Cooling capacity SEER Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SySc
roll
20-3
5 Ai
r CO SyScroll 20
Air CO 20,8 kW 3,8 0,97 l/s 73 1.477 x
1.615 x 539
SyScroll 25 Air CO
24,4 kW 4,0 1,14 l/s 74 1.477 x 1.615 x 539
SyScroll 30 Air CO
28,2 kW 3,93 1,32 l/s 74 1.477 x 1.615 x 539
SyScroll 35 Air CO
33,7 kW 3,83 1,59 l/s 75 1.477 x 1.615 x 539
SysA
qua
L
SysAqua 20 L
20,4 kW 4,24 0,97 l/s 75 1.000 x 1.983 x 1.000
SysAqua 25 L
26,6 kW 4,22 1,19 l/s 75 1.000 x 1.983 x 1.000
SysAqua 30 L
28,3 kW 4,05 1,33 l/s 75 1.000 x 1.983 x 1.000
SysAqua 35 L
37,6 kW 4,09 1,69 l/s 76 1.000 x 1.983 x 1.000
SysAqua 40 L
39,3 kW 3,91 1,83 l/s 76 1.000 x 1.983 x 1.000
SySc
roll
40-7
5 Ai
r CO
SyScroll 40 Air CO
40,8 kW 4,08 1,9 l/s 80 1.750 x 1.580 x 1.100
SyScroll 45 Air CO
44,8 kW 4,08 2,1 l/s 81 1.750 x 1.580 x 1.100
SyScroll 50 Air CO
51,9 kW 4,33 2,4 l/s 81 1.750 x 1.580 x 1.100
SyScroll 60 Air CO
60,9 kW 4,3 2,8 l/s 85 2.200 x 1.580 x 1.100
SyScroll 65 Air CO
68,9 kW 4,22 3,2 l/s 86 2.200 x 1.580 x 1.100
SyScroll 75 Air CO
76,7 kW 4,0 3,6 l/s 86 2.200 x 1.580 x 1.100
SysA
qua
L
SysAqua 45 L
49,1 kW 3,89 2,22 l/s 80 2.180 x 1.986 x 1.160
SysAqua55 L
56,0 kW 3,97 2,58 l/s 80 2.180 x 1.986 x 1.160
SysAqua65 L
69,1 kW 4,04 3,11 l/s 80 2.180 x 1.986 x 1.160
SysAqua75 L
75,1 kW 3,98 3,55 l/s 80 2.180 x 1.986 x 1.160
SysAqua90 L
96,0 kW 3,89 4,25 l/s 83 2.180 x 2.286 x 1.160
SysAqua 105 L
112,0 kW 3,89 4,89 l/s 83 2.180 x 2.286 x 1.160
SysAqua125 L 3,89 5,81 l/s 83 2.180 x
2.286 x 1.160
SySc
roll
85-1
35 A
ir CO
SyScroll 85 Air CO
84,2 kW 4,4 4,02 l/s 84 3.000 x 2.250 x 1.100
SyScroll 95 Air CO
93,2 kW 4,38 4,44 l/s 84 3.000 x 2.250 x 1.100
SyScroll 105 Air CO
104,6 kW 4,15 5 l/s 88 3.000 x 2.250 x 1.100
SyScroll 120 Air CO
118,6 kW 4,2 5,6 l/s 88 3.500 x 2.250 x 1.100
SyScroll 135 Air CO
4,35 6,3 l/s 88 3.500 x 2.250 x 1.100
AQVL
85-
140
AQVL 85 83,3 kW 4,1 3,9 l/s 85 2.555 x
2.185 x 1.095
AQVL 95 93,3 kW 4,5 4,4 l/s 85 2.555 x
2.185 x 1.095
AQVL 105 102,6 kW 4,33 4,9 l/s 85 2.555 x
2.185 x 1.095
AQVL 115 110,5 kW 4,35 5,2 l/s 85 2.555 x
2.185 x 1.095
AQVL 125 121,6 kW 4,38 5,8 l/s 89 3.155 x
2.185 x 1.095
AQVL 140 4,05 6,5 l/s 89 3.155 x 2.185 x 1.095
132,1 kW
136,5 kW
128,0 kW
NEW
Air cooled Chiller & Heat Pump | 17
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Product Family Cooling capacity SEER Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SysA
qua
L
SysAqua 140 L
134,0 kW 4,07 6,9 l/s 85 2.856 x 2.295 x 2.210
SysAqua 150 L
147,0 kW 4,01 7,4 l/s 85 2.856 x 2.295 x 2.210
SysAqua 170 L
161,2 kW 4,09 8,2 l/s 87 2.856 x 2.321 x 2.210
SysAqua 190 L
187,8 kW 3,89 9,4 l/s 88 2.856 x 2.321 x 2.210
SysAqua 210 L
208,8 kW 3,90 10,5 l/s 88 2.856 x 2.321 x 2.210
VLS
604-
1204
VLS 604 153,4 kW 3,88 7,3 l/s 93 3.300 x
2.300 x 1.100
VLS 704 176,2 kW 3,8 8,4 l/s 93 4.300 x
2.300 x 1.100
VLS 804 198,1 kW 3,88 9,4 l/s 93 4.300 x
2.300 x 1.100
VLS 904 228,4 kW 3,8 10,9 l/s 94 4.300 x
2.300 x 1.100
VLS 1004 250,3 kW 3,83 11,9 l/s 94 4.300 x
2.300 x 1.100
VLS 1104 279,1 kW 3,8 13,3 l/s 95 4.300 x
2.300 x 1.100
VLS1204 306,9 kW 3,8 14,7 l/s 95 4.300 x
2.300 x 1.100
SySc
roll
140-
360
Air E
VO C
O
SyScroll 140 Air EVO CO
144 kW 3,85 6,9 l/s 90 4.000 x 2.600 x 1.100
SyScroll 170 Air EVO CO
168,6 kW 3,83 8,0 l/s 90 4.000 x 2.600 x 1.100
SyScroll 200 Air EVO CO
196,4 kW 4,1 9,4 l/s 92 3.500 x 2.600 x 2.150
SyScroll 230 Air EVO CO
229,9 kW 4,08 11,0 l/s 92 3.500 x 2.600 x 2.150
SyScroll 260 Air EVO CO
262,6 kW 4,1 12,5 l/s 93 3.500 x 2.600 x 2.150
SyScroll 280 Air EVO CO
283,5 kW 4,0 13,5 l/s 93 3.500 x 2.600 x 2.150
SyScroll 300 Air EVO CO
309,3 kW 4,03 14,8 l/s 94 4.550 x 2.600 x 2.150
SyScroll 330 Air EVO CO
330,3 kW 4,05 15,8 l/s 95 4.550 x 2.600 x 2.150
SyScroll 360 Air EVO CO
360,7 kW 4,0 17,2 l/s 95 4.550 x 2.600 x 2.150
SySc
roll
240-
660
Air C
O
SyScroll 240 Air CO
238,1 kW 3,93 11,4 l/s 93 3.500 x 2.600 x 2.150
SyScroll 270 Air CO
267,4 kW 3,8 12,8 l/s 93 3.500 x 2.600 x 2.150
SyScroll 290 Air CO
287,4 kW 3,85 13,8 l/s 94 3.500 x 2.600 x 2.150
SyScroll 320 Air CO
316,1 kW 3,98 15,13 l/s 94 3.500 x 2.600 x 2.150
SyScroll 360 Air CO
362 kW 3,93 17,3 l/s 94 4.550 x 2.600 x 2.150
SyScroll 420 Air CO
414,2 kW 4,18 19,8 l/s 95 4.550 x 2.600 x 2.150
SyScroll 470 Air CO
469,6 kW 4,13 22,5 l/s 95 5.600 x 2.600 x 2.150
SyScroll 540 Air CO
4,38 25,6 l/s 96 5.600 x 2.600 x 2.150
SyScroll 590 Air CO
4,4 28,2 l/s 96 6.650 x 2.600 x 2.150
SyScroll 660 Air CO
4,43 31,4 l/s 97 6.650 x 2.600 x 2.150
533,7 kW
588,9 kW
654,2 kW
| Air cooled Chiller & Heat Pump18
SySc
rew
370
-125
0 Ai
r EVO
CO
SyScrew 370 Air EVO CO
364,1 kW 4,13 17,3 l/s 97 4.600 x 2.510 x 2.200
SyScrew 400 Air EVO CO
414,5 kW 4,13 19,8 l/s 98 5.700 x 2.510 x 2.200
SyScrew 450 Air EVO CO
445,5 kW 4,13 21,2 l/s 98 5.700 x 2.510 x 2.200
SyScrew 500 Air EVO CO
502,9 kW 4,13 24,0 l/s 98 5.700 x 2.510 x 2.200
SyScrew 570 Air EVO CO
562,1 kW 4,13 26,8 l/s 99 6.700 x 2.510 x 2.200
SyScrew 650 Air EVO CO
625,5 kW 4,13 29,8 l/s 99 6.700 x 2.510 x 2.200
SyScrew 700 Air EVO CO
712,9 kW 4,13 34,0 l/s 99 7.800 x 2.510 x 2.200
SyScrew 750 Air EVO CO
749,2 kW 4,13 35,7 l/s 100 7.800 x 2.510 x 2.200
SyScrew 850 Air EVO CO
839 kW 4,1 40,0 l/s 100 8.800 x 2.510 x 2.200
SyScrew 950 Air EVO CO
961,8 kW 4,13 45,9 l/s 101 9.900 x 2.510 x 2.200
SyScrew 1000 Air EVO CO
1.019 kW 4,13 48,6 l/s 101 10.900 x 2.510 x 2.200
SyScrew 1100 Air EVO CO
1.117,90 kW 4,18 53,4 l/s 102 12.000 x 2.510 x 2.200
SyScrew 1250 Air EVO CO
1.249,1 kW 4,22 59,8 l/s 103 13.000 x 2.510 x 2.200
Product Family Cooling capacity SEER Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SySc
roll
400-
900
Air
EVO
CO
SyScroll 400 Air EVO CO
398,8 kW 4,5 19,1 l/s 92 4.580 x 2.500 x 2.175
SyScroll 450 Air EVO CO
446,1 kW 4,43 21,4 l/s 93 5.620 x 2.500 x 2.175
SyScroll 490 Air EVO CO
487,7 kW 4,53 23,4 l/s 93 6.680 x 2.500 x 2.175
SyScroll 530 Air EVO CO
533,9 kW 4,4 25,6 l/s 94 6.680 x 2.500 x 2.175
SyScroll 600 Air EVO CO
597,1 kW 4,58 28,6 l/s 94 7.760 x 2.500 x 2.175
SyScroll 670 Air EVO CO
667,3 kW 4,68 32 l/s 94 7.760 x 2.500 x 2.175
SyScroll 750 Air EVO CO
4,5 35,9 l/s 95 8.900 x 2.500 x 2.175
SyScroll 800 Air EVO CO
4,5 38,3 l/s 95 8.900 x 2.500 x 2.175
SyScroll 850 Air EVO CO
4,43 40,7 l/s 95 9950 x 2500 x 2175
SyScroll 900 Air EVO CO
4,5 43,1 l/s 96 11.000 x 2.500 x 2.175
797,9 kW
847,2 kW
896,7 kW
748,3 kW
Air cooled Chiller & Heat Pump | 19
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Product Family Cooling capacity SEER Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SySc
rew
300
-140
0 Ai
r CO
SyScrew 300 Air CO
294,8 kW 2,76 14,1 l/s 95 4.600 x 2.550 x 2.200
SyScrew 360 Air CO
365 kW 2,63 17,4 l/s 96 4.600 x 2.550 x 2.200
SyScrew 410 Air CO
413 kW 3,21 19,7 l/s 97 4.600 x 2.550 x 2.200
SyScrew 450 Air CO
445 kW 3,13 21, l/s 97 4.600 x 2.550 x 2.200
SyScrew 480 Air CO
480 kW 3,02 22,9 l/s 97 4.600 x 2.550 x 2.200
SyScrew 500 Air CO
505 kW 3,03 24,1 l/s 97 4.600 x 2.550 x 2.200
SyScrew 540 Air CO
540 kW 2,91 25,8 l/s 98 5.700 x 2.550 x 2.200
SyScrew 580 Air CO
575 kW 3,22 27,4 l/s 98 6.700 x 2.550 x 2.200
SyScrew 650 Air CO
652 kW 3,22 31,1 l/s 99 6.700 x 2.550 x 2.200
SyScrew 720 Air CO
713 kW 3,22 34,1 l/s 99 6.700 x 2.550 x 2.200
SyScrew 800 Air CO
794 kW 3,23 37,9 l/s 99 6.700 x 2.550 x 2.200
SyScrew 850 Air CO
851 kW 3,22 40,6 l/s 100 8.800 x 2.550 x 2.200
SyScrew 910 Air CO
909 kW 3,22 43,4 l/s 100 8.800 x 2.550 x 2.200
SyScrew 970 Air CO
971 kW 3,23 46,3 l/s 100 8.800 x 2.550 x 2.200
SyScrew 1000 Air CO
1.008 kW 3,25 48,1 l/s 100 8.800 x 2.550 x 2.200
SyScrew 1070 Air CO
1.071 kW 3,24 51,1 l/s 100 9.900 x 2.550 x 2.200
SyScrew 1130 Air CO
1.132 kW 3,3 54,1 l/s 101 10.900 x 2.550 x 2.200
SyScrew 1170 Air CO
1.172 kW 3,26 55,9 l/s 101 10.900 x 2.550 x 2.200
SyScrew 1200 Air CO
1.218 kW 3,22 58,2 l/s 101 10.900 x 2.550 x 2.200
SyScrew 1300 Air CO 3,23 62,8 l/s 102 12.000 x
2.550 x 2.200
SyScrew 1400 Air CO 3,22 66,6 l/s 103 13.000 x
2.550 x 2.200
1.316 kW
1.395 kW
| Air cooled Chiller & Heat Pump20
Vitruve BuildingLa Réunion, France
Site: BuildingProduct: Air Cooled Chiller SyScroll 260 Air EVO COApplication: Pharmaceutical application
Air cooled Chiller & Heat Pump | 21
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Selecting guide Air Cooled Heat pump
Product Family Cooling capacity SCOP Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
Min
i Sys
Aqua
DCI
Mini SysAqua DCI 5
5 kW 3,55 0,24 l/s 63 990 x 966 x 354
Mini SysAqua DCI 7
7 kW 3,46 0,33 l/s 66 990 x 966 x 354
Mini SysAqua DCI 10
10 kW 3,34 0,48 l/s 68 970 x 1.327 x 400
Mini SysAqua DCI 12
11,2 kW 3,66 0,53 l/s 68 970 x 1.327 x 400
Mini SysAqua DCI 14
12,5 kW 3,78 0,60 l/s 70 970 x 1.327 x 400
Mini SysAqua DCI 16
14,5 kW 3,39 0,69 l/S 72 970 x 1.327 x 400
SySc
roll
20-3
0 Ai
r EVO
HP
SyScroll 20 Air EVO HP
20,4 kW 3,43 0,975 l/s 74 1.477 x 1.615 x 539
SyScroll 30 Air EVO HP
26,1 kW 3,57 1,247 l/s 75 1.477 x 1.615 x 539
SysA
qua
H
SysAqua 20 H
19,4 kW 3,37 0,97 l/s 75 1.000 x 1.983 x 1.000
SysAqua 25 H
25,3 kW 3,27 1,19 l/s 75 1.000 x 1.983 x 1.000
SysAqua 30 H
26,9 kW 3,27 1,33 l/s 75 1.000 x 1.983 x 1.000
SysAqua 35 H
35,8 kW 3,36 1,69 l/s 76 1.000 x 1.983 x 1.000
SysAqua 40 H
37,4 kW 3,40 1,83 l/s 76 1.000 x 1.983 x 1.000
SySc
roll
40-7
5 Ai
r HP
SyScroll 40 Air HP
39,2 kW 3,71 1,74 l/s 80 1.750 x 1.580 x 1.100
SyScroll 45 Air HP
43,7 kW 3,65 1,95 l/s 81 1.750 x 1.580 x 1.100
SyScroll 50 Air HP
51,7 kW 3,84 2,27 l/s 81 1.750 x 1.580 x 1.100
SyScroll 60 Air HP
58 kW 3,65 2,67 l/s 85 2.200 x 1.580 x 1.100
SyScroll 65 Air HP
69,1 kW 3,63 3,02 l/s 86 2.200 x 1.580 x 1.100
SyScroll 75 Air HP
76,3 kW 3,54 3,37 l/s 86 2.200 x 1.580 x 1.100
NEW
| Air cooled Chiller & Heat Pump22
Selection guide Air Cooled Heat Pump
Product Family Cooling capacity SCOP Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SysA
qua
H
SysAqua 45 H
46,8 kW 3,23 2,22 l/s 80 2.180 x 1.986 x 1.160
SysAqua55 H
53,3 kW 3,27 2,58 l/s 80 2.180 x 1.986 x 1.160
SysAqua65 H
65,8 kW 3,43 3,11 l/s 80 2.180 x 1.986 x 1.160
SysAqua75 H
71,6 kW 3,40 3,55 l/s 80 2.180 x 1.986 x 1.160
SysAqua90 H
91,4 kW 3,26 4,25 l/s 83 2.180 x 2.286 x 1.160
SysAqua 105 H
106,2 kW 3,31 4,88 l/s 83 2.180 x 2.286 x 1.160
SysAqua125 H
122 kW 3,35 5,80 l/s 83 2.180 x 2.286 x 1.160
SySc
roll
85-1
35 A
ir HP
SyScroll 85 Air HP
85 kW 3,56 3,77 l/s 84 3.000 x 2.250 x 1.100
SyScroll 95 Air HP
96 kW 3,51 4,16 l/s 84 3.000 x 2.250 x 1.100
SyScroll 105 Air HP
107 kW 3,36 4,69 l/s 88 3.000 x 2.250 x 1.100
SyScroll 120 Air HP
120 kW 3,31 5,44 l/s 88 3.500 x 2.250 x 1.100
SyScroll 135 Air HP
132,6 kW 3,33 5,97 l/s 88 3.500 x 2.250 x 1.100
AQVH
85-
140
AQVH 85 87 kW 3,61 3,87 l/s 85 2.555 x
2.185 x 1.095
AQVH 95 100,4 kW 3,64 4,30 l/s 85 2.555 x
2.185 x 1.095
AQVH 105 108,3 kW 3,78 4,73 l/s 85 2.555 x
2.185 x 1.095
AQVH 115 116,4 kW 3,77 5,11 l/s 85 2.555 x
2.185 x 1.095
AQVH 125 131,5 kW 3,47 5,55 l/s 89 3.155 x
2.185 x 1.095
AQVH 140 143,6 kW 3,54 6,19 l/s 89 3.155 x
2.185 x 1.095
SysA
qua
H
SysAqua 140 H
125,4 kW 3,32 6,9 l/s 85,4 2.856 x 2.295 x 2.210
SysAqua 150 H
137,6 kW 3,36 7,4 l/s 85,4 2.856 x 2.295 x 2.210
SysAqua 170 H
150,9 kW 3,31 8,2 l/s 87,0 2.856 x 2.321 x 2.210
SysAqua 190 H
175,8 kW 3,29 9,41 l/s 88,1 2.856 x 2.321 x 2.210
SysAqua 210 H
195,4 kW 3,23 10,5 l/s 88,1 2.856 x 2.321 x 2.210
VLH
604-
1204
VLH 604 169,8 kW 3,20 8,11 l/s 93 3.300 x
2.300 x 1.100
VLH 704 200,1 kW 3,41 9,56 l/s 93 4.300 x
2.300 x 1.100
VLH 804 223,2 kW 3,42 10,66 l/s 93 4.300 x
2.300 x 1.100
VLH 904 254,7 kW 3,28 12,17 l/s 94 4.300 x
2.300 x 1.100
VLH 1004 270,8 kW 3,39 12,94 l/s 94 4.300 x
2.300 x 1.100
VLH 1104 302,1 kW 3,20 14,43 l/s 95 4.300 x
2.300 x 1.100
VLH 1204 337,4 kW 3,19 16,12 l/s 95 4.300 x
2.300 x 1.100
Air cooled Chiller & Heat Pump | 23
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Product Family Cooling capacity SCOP Flow rate Acousticpower dB(A)
size (LxHxW) without water tank
SySc
roll
140-
360
Air E
VO H
P
SyScroll 140 Air EVO HP
144,9 kW 3,39 6,8 l/s 90 4.000 x 2.600 x 1.100
SyScroll 170 Air EVO HP
165,7 kW 3,42 7,88 l/s 90 4.000 x 2.600 x 1.100
SyScroll 200 Air EVO HP
200,1 kW 3,34 9,52 l/s 92 3.500 x 2.600 x 2.150
SyScroll 230 Air EVO HP
229 kW 3,46 10,91 l/s 92 3.500 x 2.600 x 2.150
SyScroll 260 Air EVO HP
262,3 kW 3,48 12,50 l/s 93 3.500 x 2.600 x 2.150
SyScroll 280 Air EVO HP
279,6 kW 3,44 13,30 l/s 93 3.500 x 2.600 x 2.150
SyScroll 300 Air EVO HP
305,6 kW 3,51 14,55 l/s 94 4.550 x 2.600 x 2.150
SyScroll 330 Air EVO HP
327,2 kW 3,44 15,58 l/s 95 4.550 x 2.600 x 2.150
SyScroll 360 Air EVO HP
361,4 kW 3,48 17,22 l/s 95 4.550 x 2.600 x 2.150
SySc
roll
240-
660
Air H
P
SyScroll 240 Air HP
255,9 kW 3,39 12,16 l/s 93 3.500 x 2.600 x 2.150
SyScroll 270 Air HP
289,1 kW 3,50 13,72 l/s 93 3.500 x 2.600 x 2.150
SyScroll 290 Air HP
313,3 kW 3,38 14,86 l/s 94 3.500 x 2.600 x 2.150
SyScroll 320 Air HP
333 kW 3,59 15,86 l/s 94 3.500 x 2.600 x 2.150
SyScroll 360 Air HP
382,4 kW 3,51 18,19 l/s 94 4.550 x 2.600 x 2.150
SyScroll 420 Air HP
444 kW 3,64 21,11 l/s 95 4.550 x 2.600 x 2.150
SyScroll 470 Air HP
491,5 kW 3,42 23,38 l/s 95 5.600 x 2.600 x 2.150
SyScroll 540 Air HP
- 26,47 l/s 96 5.600 x 2.600 x 2.150
SyScroll 590 Air HP
- 28,77 l/s 96 6.650 x 2.600 x 2.150
SyScroll 660 Air HP
- 32,27 l/s 97 6.650 x 2.600 x 2.150
SySc
roll
400-
900
Air E
VO H
P
SyScroll 400 Air EVO HP
404,4 kW 3,62 19,3 l/s 92 5.620 x 2.500 x 2.175
SyScroll 450 Air EVO HP
450,9 kW 3,62 21,5 l/s 93 5.620 x 2.500 x 2.175
SyScroll 490 Air EVO HP
492,7 kW 3,53 23,5 l/s 93 6.680 x 2.500 x 2.175
SyScroll 530 Air EVO HP
532,1 kW 3,53 25,3 l/s 94 6.680 x 2.500 x 2.175
SyScroll 580 Air EVO HP
585,8 kW - 27,9 l/s 94 7.760 x 2.500 x 2.175
SyScroll 620 Air EVO HP 627,7 kW - 29,9 l/s 95 8.800 x 2.500
x 2.175
SyScroll 670 Air EVO HP
- 32,3 l/s 95 8.800 x 2.500 x 2.175
SyScroll 750 Air EVO HP
- 36,1 l/s 95 9.950 x 2.500 x 2175
SyScroll 800 Air EVO HP
- 38,4 l/s 95 9.950 x 2.500 x 2.175
SyScroll 850 Air EVO HP
- 40,7 l/s 96 11.000 x 2.500 x 2.175
SyScroll 900 Air EVO HP
- 40,7 l/s 96 11.000 x 2.500 x 2.175
605 kW
679,1 kW
556,4 kW
807,3 kW
856,9 kW
677,7 kW
758,3 kW
901,6 kW
| Air cooled Chiller & Heat Pump24
Technical features 4 sizes Cooling capacity from 20,8 to 33,7 kW One refrigerant circuit One scroll compressor Plate evaporator (AISI 316) New control Operating low water content in the plant Pump as standard
SyScroll 20-35 Air COLeaving water temperature* °C from -8 to +18∆ T water K from 3 to 7Air temperature °C from -10 to 50Power supply voltage V/Ph/Hz 400/3+N/50 (Nominal)
* Below 5°C, glycol and electronic expansion valve is required.
Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kW of cooling capacity.
Air Cooled ChillerSyScroll 20-35 Air CO
21-34 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coil grilles Coils treatment Desuperheater Electronic expansion valve Fan speed control (standard) Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water differential pressure switch (standard) Water filter (standard) Water flow switch
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 25
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
SyScroll 20-35 Air CO 20 25 30 35Cooling capacity1 kW 20,8 24,4 28,2 33,7Power input1 kW 6,67 7,42 8,98 11,5EER 100%1 3,12 3,29 3,14 2,93Energy efficiency class A A A BESEER 3,56 3,77 3,70 3,44SEER2 3,8 4 3,93 3,83
hsc2 149 157 154 150
Sound power level3 dB(A) 73 74 74 75Sound pressure level at 10 m4 dB(A) 41 42 42 43
Water Connections (Evaporator)Type Male gas threaded Inlet/outlet diameter inch 1”1/4WeightOperating weight kg 248 279 283 298DimensionsLength mm 1.477 1.477 1.477 1.477Width mm 539 539 539 539Height mm 1.615 1.615 1.615 1.615
Physical features
SyScroll 20-35 Air CO 20 25 30 35
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump26
SysAqua 20-40 LLeaving water temperature (without glycol) °C from +5 to +18Leaving water temperature (with glycol 45%) °C from -10 to +18External air temperature °C from -10 to +50Power supply V/Ph/Hz 400/3~+N/50 (Nominal)
Air Cooled ChillerSysAqua 20-40 L
Technical features 5 sizes Cooling capacity from 20,4 to 39,3 kW EER up to 3,08 SEER up to 4,37
Product Advantages
Extra low sound level Refrigerant R410A Extented operating limits High temperature operation up to 50°C High SEER Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop Closed cabinet with inside the thermodynamic and hydraulic
parts One refrigerant circuit with tandem scroll compressors for a
higher efficiency at partial load Hydraulic circuit with or without pump in standard (including
a not mounted water filter) Modbus RTU communication protocol as standard Return or leaving water temperature control Set point compensation Night mode (extra low sound level) ON/OFF Remote Water flow switch (factory mounted) Phase monitor
20-39 kW Plate
Air cooled Scroll
R410A
Main accessories and options
All seasons Antivibration mount rubber Antivibration spring Bacnet IP Bacnet MSTP (upon request) Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Low water pressure sensor Modbus TCP/IP Outdoor coil protection grid Remote control Shut off valves Sofstarter SysCloud Variable pumps Water tank 100L Without neutral (upon request)
NEW Size 20 and variable pumps now available!
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182021
2021Ready.
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere! (optional)
Air cooled Chiller & Heat Pump | 27
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 20-40 L 20 25 30 35 40Cooling Capacity1 kW 20,40 26,60 28,30 37,60 39,30Power input1 kW 6,30 8,61 9,34 13,50 13,60Total EER 100%1 3,24 3,08 3,03 2,79 2,88ESEER1 - 4,03 3,85 3,63 3,63Energy efficiency class (EER)1 A B B C C
SEER2 4,24 4,22 4,05 4,09 3,91hsc
2 163 162 156 157 150
SEER2 4,37 4,34 4,21 4,37 4,15
hsc2 172 167 165 172 163
Sound power level3 dB(A) 75 75 75 76 76
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Following Eurovent standard.
Technical performance
Water Connections (Evaporator)Type Male gas threaded BSPP iso 228Inlet/outlet diameter inch 1”1/2WeightWithout water tank - 1 pump kg 285 295 325 335 335With water tank - 1 pump kg 450 460 490 500 500DimensionsLength mm 1.000 1.000 1.000 1.000 1.000Width without tank mm 1.000 1.000 1.000 1.000 1.000Width with tank mm 1.507 1.507 1.507 1.507 1.507Height mm 1.983 1.983 1.983 1.983 1.983
Physical features
SysAqua 20-40 L 20 25 30 35 40
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
New
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump28
Technical features 6 sizes Cooling capacity from 40,8 to 76,7 kW
3 versions: STD (Standard version) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions: Standard version (STD) Super Low Noise version (S) One refrigerant circuit 2 scroll compressors (one tandem) Plate evaporator (AISI 316) Operating low water content in the plant “Brine” version for process application
Air Cooled ChillerSyScroll 40-75 Air CO
41-77 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker Coils grilles (standard) Coils treatments Compressors jackets (standard S) Desuperheater Electronic expansion valves Fan speed control (down to -18°C) Hydrokit with 1 or 2 pumps with or without buffer tank Hydrometer (standard) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sequencer for up to 4 chillers installation Softstart Water filter (standard) Water differential switch (standard) Water flow switch (standard)
SyScroll 40-75 Air COLeaving water temperature * °C from -8 to +18Water ∆ T K from +3 to +7Air Temperature (STD) °C from -18 to +46Air Temperature (S) °C from -18 to +42Air Temperature (HT) °C from -20 to +50Power Supply V/Ph/Hz 400/3+N/50 (Nominal)
* Below 5°C, glycol and electronic expansion valve are required.
Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kW of output.
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182021
2021Ready.
Air cooled Chiller & Heat Pump | 29
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScroll 40-75 Air CO (STD-HPF-HT) 40 45 50 60 65 75Cooling capacity1 kW 40,8 44,8 51,9 60,9 68,9 76,7Power input1 kW 14,0 16,2 18,6 20,5 23,5 27,9EER1 2,91 2,77 2,79 2,97 2,93 2,75Energy efficiency class B C C B B CESEER 4,08 3,87 3,89 4,01 4,07 3,73
SEER2 4,08 4,08 4,33 4,3 4,22 4
hsc2 160 160 170 169 166 157
SEER2 - - 4,33 4,3 4,22 -
hsc2 - - 170 169 166 -
Sound power level3 dB(A) 78 79 79 83 84 84Sound pressure level at 10 m4 dB(A) 47 47 47 52 52 52
SyScroll 40-75 Air CO S 40 45 50 60 65 75Cooling capacity1 kW 39,4 43,1 49,6 59,0 64,0 73,7Power input1 kW 14,3 16,6 19,4 20,7 23,6 28,7EER1 2,76 2,60 2,56 2,85 2,71 2,57Energy efficiency class C D D C C DESEER 3,87 3,62 3,58 3,85 3,77 3,50
SEER2 4,08 4,1 4,25 4,4 4,2 4
hsc2 160 161 167 173 165 157
SEER2 - - 4,25 4,4 4,2 -
hsc2 - - 167 173 165 -
Sound power level3 dB(A) 74 75 75 78 79 79Sound pressure level at 10 m4 dB(A) 42 44 44 46 47 47
Physical features
Water Connection (Evaporator)Connection type Male gas threadedInlet/outlet diameter inch 2”WeightOperating weight kg 413 421 446 489 496 502DimensionsLength mm 1.750 1.750 1.750 2.200 2.200 2.200Width mm 1.100 1.100 1.100 1.100 1.100 1.100Height mm 1.580 1.580 1.580 1.580 1.580 1.580
SyScroll 40-75 Air CO 40 45 50 60 65 75
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
ErP20182021
ErP20182018
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump30
Air Cooled ChillerSysAqua 45-125 L
Technical features 7 sizes Cooling capacity from 49,1 to 128,0 kW EER up to 3,13 SEER up to 4,28
Product Advantages Low sound level Refrigerant R410A Extended operating limits High temperature operation up to 50°C High SEER Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop Closed cabinet with inside the thermodynamic and hydraulic
parts One refrigerant circuit with tandem scroll compressors for a
higher efficiency at partial load Hydraulic circuit without pump in standard (including a not
mounted water filter) Modbus RTU communication protocol as standard Return or leaving water temperature control Set point compensation Night mode (extra low sound level) On/Of Remote Water flow switch (factory mounted) Phase monitor
49-128 kW Plate
Air cooled Scroll
R410A
SysAqua 45-125 LLeaving water temperature (without glycol) °C from +5 to +18Leaving water temperature (with glycol 45%) °C from -10 to +18External air temperature °C from -10 to +50Power supply V/Ph/Hz 400/3~+N/50 (Nominal)
Accessories and options All seasons Antivibration mount rubber Antivibration spring Bacnet MSTP (upon request) Bacnet IP Compatible with container transportation Extra low noise version Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Hydraulic circuit pack single or double pump Low water pressure sensor Modbus TCP/IP Outdoor coil protection grid Refrigerant gauges HP/LP Remote control Shut off valves Sofstarter SysCloud Variable pumps Water tank 300L Without neutral (upon request)
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182021
2021Ready.
NEW Variable pumps now available!
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere! (optional)
Air cooled Chiller & Heat Pump | 31
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 45-125 L 45 55 65 75 90 105 125Cooling Capacity1 kW 49,10 56,00 69,10 75,10 96,00 112,00 128,00Power input1 kW 16,90 19,70 22,10 24, 30 34,40 38,10 46,40Total EER 100%1 2,91 2,84 3,13 3,10 2,79 2,93 2,76ESSER1 3,96 3,87 4,12 4,18 3,96 4,16 3,92Energy efficiency class (EER)1 B C A A C B C
SEER2 3,89 3,97 4,04 3,98 3,89 3,89 3,89hsc
2 150 153 156 153 149 159 150SEER2 4,10 4,11 4,23 4,17 4,11 4,16 4,28
hsc2 161 161 166 164 161 164 168
Sound power level3 dB(A) 80 80 80 80 83 83 83
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Following Eurovent standard.
Technical performance
Water Connection (Evaporator)Type Male gas threaded BSPP iso 228Inlet/Outlet diameter inch 2” 2” 2” 2” 2”1/2 2”1/2 2”1/2WeightWithout water tank - 1 pump kg 545 545 615 615 795 905 925With water tank - 1 pump kg 1.005 1.005 1.075 1.075 1.255 1.365 1.385DimensionsLength without water tank mm 2.180 2.180 2.180 2.180 2.180 2.180 2.180Length with water tank mm 2.680 2.680 2.680 2.680 2.680 2.680 2.680Width mm 1.160 1.160 1.160 1.160 1.160 1.160 1.160Height mm 1.986 1.986 1.986 1.986 2.286 2.286 2.286
Technical features
SysAqua 45-125 L 45 55 65 75 90 105 125
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump32
Air Cooled ChillerSyScroll 85-135 Air CO
Technical features 5 sizes Cooling capacity from 84,2 to 132,1 kW 3 versions:
STD (Standard version) HT (High Temperature version) HPF (High Pressure Fans version)
2 acoustic versions: Standard version (STD)
Super Low Noise version (S) One refrigerant circuit 2 Scroll compressors (tandem) One plate evaporator Microchannel coils Microprocessor control Electronic expansion valve as standard E-Coating coil treatment as standard "Brine" version for process application
84-132 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard) Compressors jackets Desuperheater Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch (standard) Water pressure switch
SyScroll 85-135 Air CO
Leaving water temperature
Water °С from +6 to +18Water with glycol +electronic expansion valve* °С from -8 to +5
∆ T Water К from 3 to 7
Air temperatureBLN °С from +10 to +45S °С from -14 to +42HT °С from -16 to +47
External static pressureStandard fans Pa 0High pressure fans (HPF) Pa < 120
Power supply V/Ph/Hz 400/3/50 (Nominal)
* For operation below 0°C contact sales office.
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182021
2021Ready.
Air cooled Chiller & Heat Pump | 33
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScroll 85-135 Air CO 85 95 105 120 135Cooling capacity1 kW 84,2 93,2 104,6 118,6 132,1Power input1 kW 27,2 31,5 37,7 42,0 47,6EER1 3,09 2,96 2,77 2,82 2,78ESSER 3,94 4,35 4,00 4,01 4,03Energy efficiency class B C C C C
SEER2 4,4 4,38 4,15 4,2 4,35
hsc2 173 172 163 165 171
SEER2 4,4 4,38 4,15 4,2 4,35
hsc2 173 172 163 165 171
Sound power level3 dB(A) 84 84 88 88 88Sound pressure level at 10 m4 dB(A) 52 52 56 56 56
SyScroll 85-135 Air CO S 85 95 105 120 135Cooling capacity1 kW 81,1 89,3 101,4 113,5 126,0Power input1 kW 28,0 32,8 38,6 43,0 49,6EER1 2,90 2,72 2,63 2,64 2,54ESSER 3,91 4,32 3,98 4,03 4,00Energy efficiency class C C D D D
SEER2 4,4 4,3 4,28 4,28 4,3
hsc2 173 169 168 168 169
SEER2 4,4 4,3 4,28 4,28 4,3
hsc2 173 169 168 168 169
Sound power level3 dB(A) 82 82 85 85 85Sound pressure level at 10 m4 dB(A) 50 50 53 53 53
Physical features
Water connections (Evaporator)Type Male gas threadedInlet/outlet diameter inch 2”1/2WeightOperating weight - Kg 715 786 867 919 959Operating weight S Kg 708 779 858 908 946DimensionsLength mm 3.000 3.500Width mm 1.100 1.100Height mm 2.250 2.250
SyScroll 85-135 Air CO 85 95 105 120 135
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
ErP20182021
ErP20182018
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump34
Technical features 6 sizes Cooling capacity from 83,3 to 136,5 kW 4 versions:
STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans)
2 acoustic versions: Standard version (STD)
Extra Low Noise version (ELN) Two refrigerant circuits 4 Scroll compressors (tandem) Plate evaporator (AISI 316) Microprocessor control Low operating water content in the plant Electronic expansion valve as standard “Brine” version for process application E-Coating coil treatment as standard
Air Cooled ChillerAQVL 85-140
AQVL 85-140
Leaving water temperatureWater °С from +5 to +18Water with glycol °С from 0 to +18Water with glycol (Brine version) °C from -8 to +18
Air temperature
BLN °С from +5 to +47ELN °С from -18 to +44
HSE/HT °Сfrom -18 to +50 (85-115)
from -18 to +47 (125-140)
External static pressureStandard fans Pa 0High Pressure Fans (HPF) Pa < 120
Power supply V/Ph/Hz 400/3/50 (Nominal)
83-137 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets as standard on ELN Desuperheater & Total heat recovery Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Pressure switch Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure & Water flow switch (standard) Water filter
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
ErP20182021
2021Ready.
Air cooled Chiller & Heat Pump | 35
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
AQVL 85-140 BLN 85 95 105 115 125 140Cooling capacity1 kW 83,3 93,3 102,6 110,5 121,6 136,5Power input1 kW 27,1 31,0 33,6 36,6 40,9 46,1EER1 3,08 3,01 3,05 3,02 2,97 2,96Energy efficiency class B B B B B BESEER 4,16 4,15 4,07 4,12 3,95 4,01EER HSE1 3,19 3,09 3,13 3,10 3,05 3,03Energy efficiency class A B A A B BESEER HSE 4,06 4,12 4,23 4,19 3,96 4,08
SEER2/ hsc2 4,1/ 161 4,5/ 177 4,33/ 170 4,35/ 171 4,38/ 172 4,05/ 159
SEER HSE2/ hsc HSE2 4,5/177 4,5/177 4,68/184 4,7/185 4,38/172 4,33/170
SEER2/ hsc2 - 4,5/ 177 4,33/ 170 4,35/ 171 4,38/ 172 -
SEER HSE2/ hsc HSE2 4,5/177 4,5/177 4,68/184 4,7/185 4,38/172 4,33/170Sound power level3 dB(A) 84 84 84 84 88 88Sound pressure level at 10 m4 dB(A) 52 52 52 52 56 56Sound power level HPF3 dB(A) 92 92 92 92 95 95Sound pressure level at 10 m HPF4 dB(A) 60 60 60 60 63 63
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.5 Input power (only compressors).
AQVL 85-140 ELN 85 95 105 115 125 140Cooling capacity1 kW 80,6 89,9 98,3 105,6 119,6 133,5Power input1 kW 26,1 30,2 32,8 35,7 39,9 45,1EER1 2,87 2,75 2,77 2,73 2,90 2,86Energy efficiency class C C C C B CESEER 3,91 3,78 3,81 3,67 3,92 3,93EER HSE1 3,00 2,87 2,87 2,81 2,96 2,91Energy efficiency class B C C C B BESEER HSE 3,91 3,87 3,87 3,79 3,99 3,94
SEER2/ hsc2 4,03/ 158 4,03/ 158 4,18/ 164 4,18/ 164 4,45/ 175 4,25/ 167
SEER HSE2/ hsc HSE2 4,58/ 180 4,53/ 178 4,63/ 182 4,65/183 4,65/183 4,5/177
SEER2/ hsc2 - - 4,18/ 164 4,18/ 164 4,45/ 175 4,25/ 167
SEER HSE2/ hsc HSE2 4,58/ 180 4,53/ 178 4,63/ 182 4,65/183 4,65/183 4,5/177Sound power level3 dB(A) 82 82 82 82 86 86Sound pressure level at 10 m4 dB(A) 50 50 50 50 54 54
AQVL 85-140 HT 85 95 105 115 125 140Cooling capacity1 kW 86,2 97,0 106,9 115,3 124,6 139,6Power input5 kW 23,2 26,6 28,9 31,4 36,1 40,9EER 3,10 3,10 3,19 3,21 3,06 3,07ESEER 4,34 4,34 4,46 4,49 4,29 4,30SEER2 4,5 4,5 4,68 4,7 4,38 4,33
hsc2 177 177 184 185 172 170
Sound power level3 dB(A) 95 95 95 95 95 95Sound pressure level at 10 m4 dB(A) 63 63 63 63 63 63
Physical features
Water connection (Evaporator)Connection type Male gas threadedInlet/outlet diameter inch 2½”WeightOperating weight BLN kg 1.058 1.072 1.111 1.143 1.183 1.262Operating weight ELN kg 1.088 1.102 1.141 1.173 1.213 1.292Operating weight HT kg 1.058 1.072 1.111 1.143 1.183 1.262DimensionsLength mm 2.555 2.555 2.555 2.555 3.155 3.155Width mm 1.095 1.095 1.095 1.095 1.095 1.095Height mm 2.185 2.185 2.185 2.185 2.185 2.185
AQVL 85-140 85 95 105 115 125 140
ErP20182021
ErP20182018
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump36
Air Cooled ChillerSysAqua 140-210 L
Technical features 5 sizes Cooling capacity from 134 to 208,8 kW EER up to 3,03 SEER up to 4,36
Product Advantages SysCloud as standard Extra low sound level Refrigerant R410A Extended operating limits High temperature operation up to 50°C High SEER Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop Two refrigerant circuits with tandem scroll compressors per
circuit for a higher efficiency at partial load Hydraulic circuit without pump in standard (including a not
mounted water filter) Modbus RTU and TCP/IP communication protocols as standard Return or leaving water temperature control Double water set point Night mode (extra low sound level) On/Of Remote Water flow switch (factory mounted) Phase monitor
134 - 209 kW Plate
Air cooled Scroll
R410A
SysAqua 140-210 LLeaving water temperature (without glycol) °C from +5 to +18Leaving water temperature (with glycol 45%) °C from -10 to +18External air temperature °C from -10 to +50Power supply V/Ph/Hz 400/3~+N/50 (Nominal)
Accessories and options All seasons Antivibration mount rubber Antivibration spring Bacnet IP Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Hydraulic circuit pack single or double pump Hydraulic gauges Low water pressure sensor Outdoor coil protection grid Refrigerant gauges HP/LP Remote control Shut off valves Sofstarter Variable pumps Water tank 300L Without neutral
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP2018
ErP20182021
2021Ready.
NEW Variable pumps now available!
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere!
Air cooled Chiller & Heat Pump | 37
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 140-210 L 140 150 170 190 210Cooling capacity1 kW 134,0 147,0 161,0 188,0 209,0 Power input1 kW 44,2 49,1 53,5 65,7 73,0Total EER 100%1 3,03 3,00 3,02 2,86 2,86ESEER1 4,16 4,20 4,14 4,08 4,10Energy efficiency class (EER)1 B B B C C
SEER2 4,07 4,01 4,09 3,89 3,90hsc
2 157 154 157 150 150SEER2 4,24 4,19 4,36 4,10 4,09
hsc2 166 166 171 161 161
Sound power level3 dB(A) 85 85 87 88 88
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Following Eurovent standard.
Technical performance
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 2”1/2WeightWithout water tank - 1 pump kg 1.685 1.705 1.798 1.891 2.201With water tank - 1 pump kg 2.139 2.159 2.253 2.343 2.653DimensionsLength without water tank mm 2.856 2.856 2.856 2.856 2.856Length with water tank mm 3.666 3.666 3.666 3.666 3.666Width mm 2.210 2.210 2.210 2.210 2.210Height mm 2.295 2.295 2.321 2.321 2.321
Physical features
SysAqua 140-210 L 140 150 170 190 210
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump38
Air Cooled ChillerVLS 604-1204
VLS 604-1204 604 704 804 904 1004 1004 1204
Chilled liquid
Water °C from +6 to +15Water with glycol °C from 0 to +15Water with glycol (Brine version) °C from -8 to +15
∆ T K from 3 to 8
Ambient airBLN °C -5 to +472 -5 to +472 0 to +462 0 to +472 0 to +462 0 to +452 0 to +452
LN/ELN1 °C -5 to +452 -5 to +452 0 to +442 0 to +452 0 to +442 0 to +422 0 to +422
HT °C -18 to +492 -18 to +492 -18 to +482 -18 to +492 -18 to +482 -18 to +472 -18 to +472
External static pressure
Standard fans Pa 0Inverter fans HPF Pa <120
Power supply V/Ph/Hz 400/3/50 (Nominal)
153-307 kW Plate
Air Scroll
R410A
1 Minimum air temperature -18°C with Fan speed control (standard ELN). 2 High Pressure at 40,5 bar.
Chillers suitable for operation without buffer tank for water content greater than 3 liters of water per kW of output.
Technical feature 7 sizes Cooling capacity from 153,4 to 306,9 kW 3 versions:
STD (Standard); HT (High Temperature);
HPF (High Pressure Fans) 3 acoustic versions:
BLN (Basic Low Noise) LN (Low Noise)
ELN (Extra Low Noise) Two refrigerant circuits 4 Scroll compressors (tandem) Plate evaporator (AISI 316) Microprocessor control Microchannel coils (CO only version) Electronic expansion valve Inverter fans and HT “Brine” version for process application (upon request) E-Coating coil treatment as standard
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater and total heat recovery VLR Fan speed control (-18°C) Hydrokit with 1 or 2 pumps with or without buffer tank (500 lt)(
+1mt of length) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
ErP2018
HSE version
Air cooled Chiller & Heat Pump | 39
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
VLS HSE 604-1204 BLN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 153,4 176,2 198,1 228,4 250,3 279,1 306,9Power input1 kW 54,4 64,3 70,5 80,7 84,85 97,9 113,25EER1/ Energy efficiency class 2,82/C 2,74/C 2,81/C 2,83/C 2,95/B 2,85/C 2,71/CESEER 3,81 3,79 3,89 3,9 4,07 3,97 3,86SEER2 3,88 3,8 3,88 3,8 3,83 3,8 3,8
hsc2 152 149 152 149 150 149 149
Sound power level3 dB(A) 91 91 91 92 92 93 93Sound pressure level at 10 m4 dB(A) 59 59 59 60 60 61 61
VLS HSE 604-1204 LN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 149,4 171,2 192,1 222,4 241,3 266,2 292,0Power input1 kW 54,5 64,6 71,7 81,5 86,2 100,8 117,7EER1/ Energy efficiency class 2,74/C 2,65/D 2,68/D 2,73/C 2,8/C 2,64/D 2,48/EESEER 4,1 3,95 3,96 3,89 4,07 4 3,84SEER2 4,13 3,98 3,98 3,98 3,8 3,8 3,8
hsc2 162 156 156 156 149 149 149
Sound power level3 dB(A) 87 87 87 88 88 89 89Sound pressure level at 10 m4 dB(A) 55 55 55 56 56 57 57
VLS HSE 604-1204 ELN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 145,4 166,3 186,2 216,5 234,4 258,2 282,1Power input 1 kW 55,7 66,8 74,2 83,6 88,8 105 122,1EER1/ Energy efficiency class 2,61/D 2,49/E 2,51/D 2,59/D 2,64/D 2,46/E 2,31/EESEER 4,1 3,88 3,9 3,88 4,03 3,92 3,78SEER2 4,15 3,95 4,08 3,98 3,83 3,8 3,83
hsc2 163 155 160 156 150 149 150
Sound power level3 dB(A) 83 83 83 84 84 85 85Sound pressure level at 10 m4 dB(A) 51 51 51 52 52 53 53
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.5 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature. 6 Input power (only compressors).7 Data refers to 7/12°C evaporator water temperature and 35°C condenser air temperature.8 Data based on 7°C leaving chilled water temperature and 45°C condenser warm water temperature.
VLS STD/HPF 604-1204 BLN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 153,4 176,2 198,1 228,4 250,3 279,1 306,9Power input1 kW 55,8 66,0 72,3 83,1 86,9 100,0 114,9EER1 2,75 2,67 2,74 2,75 2,88 2,79 2,67Energy efficiency class C D C C C C DESEER 3,50 3,47 3,44 3,43 3,59 3,52 3,45Sound power level2 dB(A) 91 91 91 92 92 93 93Sound pressure level at 10 m3 dB(A) 59 59 59 60 60 61 61
VLS STD 604-1204 LN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 149,4 171,2 192,1 222,4 241,3 266,2 292,0Power input1 kW 56,4 66,4 73,3 83,6 88,7 104,0 120,2EER1 2,65 2,58 2,62 2,66 2,72 2,56 2,43Energy efficiency class D D D D C D EESEER 3,72 3,63 3,65 3,58 3,75 3,66 3,57Sound power level2 dB(A) 87 87 87 88 88 89 89Sound pressure level at 10 m3 dB(A) 55 55 55 56 56 57 57
VLS STD 604-1204 ELN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 145,4 166,3 186,2 216,5 234,4 258,2 282,1Power input 1 kW 57,9 68,7 76,3 86,3 91,2 106,7 124,8EER1 2,51 2,42 2,44 2,51 2,57 2,42 2,26Energy efficiency class D E E D D E FESEER 3,62 3,52 3,53 3,59 3,68 3,58 3,47Sound power level2 dB(A) 83 83 83 84 84 85 85Sound pressure level at 10 m3 dB(A) 51 51 51 52 52 53 53
| Air cooled Chiller & Heat Pump40
Water connection (Evaporator)Connection type Male gas threadedInlet/outlet diameter inch 2½” 2½” 2½” 3” 3” 3” 3”WeightOperating weight BLN / LN kg 1.315 1.490 1.625 1.770 1.820 1.835 1.840Operating weight ELN kg 1.350 1.525 1.660 1.805 1.860 1.875 1.880Operating weight HT kg 1.345 1.520 1.655 1.810 1.860 1.875 1.880Operating weight VLR kg 1.536 1.725 1.880 2.101 2.230 2.320 2.329DimensionsLength mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300
VLS 604-1204 604 704 804 904 1004 1104 1204
Physical features
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
VLS 604-1204 HT 604 704 804 904 1004 1104 1204Cooling capacity5 kW 156,1 178,6 200,9 231,7 254,2 282,4 313,3Power input6 kW 56,5 66,1 72,2 83,4 87,6 101 114EER 2,74 2,69 2,77 2,77 2,89 2,78 2,74SEER2 3,88 3,8 3,88 3,8 3,83 3,8 3,8
hsc2 152 149 152 149 150 149 149
Sound power level3 dB(A) 99 99 99 100 100 100 100Sound pressure level at 10 m4 dB(A) 67 67 67 68 68 68 68
VLR 604-1204 604 704 804 904 1004 1104 1204Cooling capacity7 kW 152,0 176,0 200,0 230,0 250,0 277,0 306,0Power input6 kW 56,4 66,6 73 82,8 86,6 100 114Heat recovery capacity8 kW 191,0 222,8 251,3 288,3 310,7 348,7 388,6EER 2,70 2,64 2,74 2,78 2,89 2,77 2,68
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.5 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature. 6 Input power (only compressors).7 Data refers to 7/12°C evaporator water temperature and 35°C condenser air temperature.8 Data based on 7°C leaving chilled water temperature and 45°C condenser warm water temperature.
Air cooled Chiller & Heat Pump | 41
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Mucem History MuseumMarseille, France
Site: MuseumProduct: Air cooled chiller AQCL 120Application: Air conditioning
| Air cooled Chiller & Heat Pump42
Air Cooled ChillerSyScroll 140-360 Air EVO CO
Technical features 9 sizes Cooling capacity from 144 to 360,7 kW 4 versions:
STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
“Brine” version: Cooling only for process application LWT -10°C Two refrigerant circuits 4 scroll compressor (tandem) Electronic expansion valve Microchannel coils E-Coating coil treatment as standard Plate heat exchanger evaporator
144-361 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater and total heat recovery (TR version) Fan speed control (-14 °C in cooling mode – standard as
Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank (350 lt
140-170, 500 lt 200-360) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
SyScroll 140-360 Air EVO CO
Chilled liquid
Liquid outlettemperature
Water °C from +5 to +18Water with glycol* °C from -10 to +5Temperature spread K from 3 to 7
Maximum operating pressure bar 6
Ambient air
Air enteringtemperature cooling
- °C from +5 to +48L °C from +0 to +46S °C from -14 to +44EC-HT °C from-18 to +50
Externalstatic pressure
Temperature spread Pa 0High pressure fans (HPF) Pa <120
Power supply voltage1 V/Ph/Hz 400/3/50 (nominal)
1 Voltage 400V +/- 10%.* For Liquid outlet temperature <0 °C provide Brine Version (available for CO; upon request for HP).
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
ErP20182021
2021Ready.
Air cooled Chiller & Heat Pump | 43
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performanceSyScroll 140-360 Air EVO CO 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 144,0 168,6 196,4 229,9 262,6 283,5 309,3 330,3 360,7Input power1 kW 44,7 54,2 62,0 73,9 83,4 90,3 98,5 103,9 116,0EER1 / Energy efficiency class / EER* 3,2/A/3,2 3,1/A/3,1 3,2/A/3,2 3,1/A/3,2 3,1/A/3,2 3,1/A/3,2 3,1/A/3,2 3,2/A/3,2 3,1/A/3,2ESEER / ESEER* 3,96/4,2 3,81/4,0 4,0/4,2 4,0/4,22 4,05/4,3 4,0/4,24 4,0/4,21 4,1/4,26 4,0/4,2
SEER / SEER*2 3,85/3,95 3,83/ 3,85 4,1/4,18 4,08/4,15 4,1/4,18 4,0/4,08 4,03/4,13 4,05/4,13 4,0/4,08
hsc / hsc*2 151/155 150/151 161/164 160/163 161/164 157/160 158/162 159/162 157/160
SEER*2/ hsc*2 - - 4,18/164 4,15/163 4,18/164 - 4,13/162 4,13/162 -
Sound power level3 dB(A) 90 90 92 92 93 93 94 95 95Sound pressure level 10 m4 dB(A) 58 58 60 60 61 61 62 63 63
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.5 Data refers to 7°C leaving chilled water temperature and 35°C air temperature.6 Input power (only compressors).7 Nominal cooling capacity refers to 7°C leaving chilled water temperature and 45°C leaving warm water temperature.* High Efficiency Units (EC) with inverter fans.
Water Connections (Evaporator)Type Male gas threadedInlet/outlet water connection inch 2”1/2 2”1/2 2”1/2 3” 3” 3” 3” 3” 3”WeightOperating weight - / L kg 1.157 1.200 1.492 1.617 1.765 1.705 2.286 2.303 2.313Operating weight S kg 1.162 1.205 1.497 1.622 1.770 1.770 2.291 2.308 2.318Operating weight HT kg 1.187 1.230 1.542 1.667 1.825 1.825 2.356 2.383 2.393Operating weight TR kg 1.342 1.386 1.885 2.028 2.250 2.250 2.876 2.969 2.969DimensionsLength mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
Physical features
SyScroll 140-360 Air EVO TR 140 170 200 230 260 280 300 330 360Nominal cooling capacity7 kW 141,8 169,7 189,2 230,5 260,5 283,7 308,1 324,1 359,8Input power6 kW 39,9 47,9 55,3 64,0 73,2 78,9 86,0 91,6 101,1EER 3,43 3,40 3,29 3,47 3,44 3,46 3,48 3,43 3,43Heat recovery capacity 183,2 219,7 246,7 296,9 336,2 365,7 396,7 418,6 464,7
SyScroll 140-360 Air EVO CO HT 140 170 200 230 260 280 300 330 360Nominal cooling capacity5 kW 145,3 170,2 197,9 232,0 264,7 286,0 312,0 332,9 363,8Input power6 kW 38,7 47,9 52,2 63,7 71,4 78,2 84,5 88,1 99,7EER / Energy efficiency class 3,09/B 3,02/B 3,00/B 2,99/B 3,01/B 3,02/B 3,01/B 3,03/B 2,99/BESEER 3,88 3,72 3,92 3,92 3,99 3,94 3,93 4,06 3,92SEER2 3,95 3,85 4,18 4,15 4,18 4,08 4,13 4,13 4,08
hsc2 155 151 164 163 164 160 162 162 160
Sound power level3 dB(A) 92 92 94 94 96 96 97 98 98Sound pressure level 10 m4 dB(A) 60 60 62 62 64 64 65 66 66
SyScroll 140-360 Air EVO CO S 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 132,5 152,9 182,3 209,4 241,0 258,7 282,5 304,3 328,5Input power1 kW 47,0 57,5 63,3 78,7 88,0 96,2 104,6 108,7 123,5EER1 / Energy efficiency class /EER* 2,8/C/2,9 2,7/D/2,7 2,9/C/2,9 2,7/C/2,7 2,7/C/2,8 2,7/D/2,7 2,7/C/2,7 2,8/C/2,8 2,6/C/2,7ESEER / ESEER* 4,12/4,3 4,0/4,2 4,16/4,37 4,16/4,39 4,17/4,4 4,18/4,4 4,17/4,38 4,18/4,35 4,16/4,37
SEER / SEER*2 4,0/4,13 3,83/3,95 4,18/4,3 4,2/4,33 4,13/4,25 4,0/4,13 4,03/4,13 4,05/4,15 4,0/4,1
hsc / hsc*2 157/162 150/155 164/169 165/170 162/167 157/162 158/162 159/163 157/161
SEER*2/ hsc*2 - - 4,3/169 4,33/170 4,25/167 4,13/162 4,13/162 4,15/163 4,1/161
Sound power level3 dB(A) 79 79 82 82 83 83 85 86 86Sound pressure level 10 m4 dB(A) 47 47 50 50 51 51 53 54 54
SyScroll 140-360 Air EVO CO L 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 139,9 162,9 191,5 222,9 255,1 275,0 300,1 321,3 349,5Input power1 kW 45,0 54,9 61,4 74,3 83,6 91,1 99,0 103,7 116,5EER1 / Energy efficiency class / EER* 3,1/A/ 3,2 2,97/B/3 3,1/A/3,2 3/B/3,04 3,0/B/3,1 3,0/B/3,1 3,0/B/3,1 3,1/A/3,2 3/B/3,04ESEER / ESEER* 4,0/4,20 3,9/4,1 4,08/4,28 4,08/4,3 4,1/4,34 4,1/4,33 4,09/4,3 4,14/4,3 4,08/4,28
SEER / SEER*2 4,03/3,85 3,88/4,0 4,2/4,3 4,2/4,3 4,18/4,28 4,1/4,2 4,08/4,15 4,1/4,18 4,05/4,13
hsc / hsc*2 158/151 152/157 165/169 165/169 164/168 161/165 160/163 161/164 159/162
SEER*2/ hsc*2 3,85/151 - 4,28/169 4,3/169 4,28/168 4,2/165 4,15/163 4,18/164 -
Sound power level3 dB(A) 85 85 87 87 88 88 89 90 90Sound pressure level 10 m4 dB(A) 53 53 55 55 56 56 57 58 58
SyScroll 140-360 Air EVO CO
ErP20182018
ErP 2021
ErP20182018
ErP 2021
ErP20182018
ErP 2021
| Air cooled Chiller & Heat Pump44
Air Cooled ChillerSyScroll 400-900 Air EVO CO
Technical features 10 sizes Cooling capacity from 399 to 897 kW 4 versions:
STD (Standard) EC (Invert fans) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions:
(Standard) S (Super Low Noise) "Brine" Version:
Cooling only for process application LWT -10°C Two refrigerant circuits 4 / 5 / 6 / 8 Scroll compressors Plate Evaporator Electronic expansion valve Microchannel coils E-Coating coil treatment as standard
399-897 kW Plate
Air Scroll
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater and total heat recovery (TR version) Fan speed control (standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank (500 lt
400-450, 1000 lt 470-670) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
SyScroll 400-900 Air EVO CO
Chilled liquid
Liquid outlettemperature
Water °C from +5 to +18Water with glycol* °C from -10 to +5ΔT K from 3 to 7
Maximum operating pressure bar 6
Ambient air
Air enteringtemperature cooling
_ / EC °C from +10 to +48S / EC S °C from -18 to +48HT °C from-18 to +52
Externalstatic pressure
Standard fans Pa 0High pressure fans (HPF) Pa <120
Power supply1 V/Ph/Hz 400/3/50 (Nominal)
1 Voltage 400V +/- 10%.* For Liquid outlet temperature <-3 °C provide Brine Version .
www.sysoftac.com
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182021
2021Ready.
Air cooled Chiller & Heat Pump | 45
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScroll 400-900 Air EVO CO 400 450 490 530 600 670 750 800 850 900Nominal cooling capacity1 kW 398,8 446,1 487,7 533,9 597,1 667,3 748,3 797,9 847,2 896,7Input power1 kW 128,6 142,8 157,1 172,1 192,1 215,0 241,7 257,4 272,4 286,7EER1 / Energy efficiency class 3,10/A 3,12/A 3,10/A 3,10/A 3,11/A 3,10/A 3,10/A 3,10/A 3,11/A 3,13/AESEER 4,16 4,26 4,29 4,16 4,14 4,24 4,09 4,08 4,13 4,12EER*1 / Energy efficiency class 3,18/A 3,21/A 3,19/A 3,18/A 3,19/A 3,18/A 3,17/A 3,17/A 3,19/A 3,21/AESEER* 4,28 4,43 4,44 4,30 4,32 4,41 4,21 4,21 4,28 4,27
SEER2/ hsc2 4,5/177 4,43/174 4,53/178 4,4/173 4,58/180 4,68/184 4,5/177 4,5/177 4,43/174 4,5/177
SEER*2/ hsc*2 4,68/184 4,6/181 4,68/184 4,58/180 4,83/190 4,85/191 4,65/183 4,68/184 4,6/181 4,63/182
SEER2/ hsc2 4,5/177 - - - 4,58/180 4,68/184 - - - -
SEER*2/ hsc*2 4,68/184 4,6/181 4,68/184 4,58/180 4,83/190 4,85/191 4,65/183 4,68/184 4,6/181 4,63/182
Sound power level3 dB(A) 92 93 93 94 94 94 95 95 95 96Sound pressure level at 10 m4 dB(A) 60 61 60 61 61 61 62 62 62 63
1 Water / Plant side heat exchanger: RWT = 12 °C / LWT = 7 °C. Air / Source side heat exchanger: OAT = 35 °C. Declared data are in accordance with EN14511 / 2013.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound power levels is declared in nominal full load condition (cooling operation), referring to ISO standard 9614, in accordance with Eurovent certification program.4 Sound pressure level refer to ISO Standard 3744, parallelepiped shape in a free field on a reflective surface. 5 Water / Plant side heat exchanger: RWT = 12 °C / LWT = 7 °C. Water / Recovery side heat exchanger: RWT = 40 °C / LWT = 45 °C.* EC version: brushless fan motors version.
Water Connections (Evaporator and Condenser)Type VictaulicInlet/outlet water connection inch 4" 5" 6" WeightOperating weight _ / EC / HPF kg 3.028 3.367 3.783 4.069 4.317 4.524 5.536 5.607 5.906 6.253Operating weight S / EC S / HT kg 3.318 3.656 4.069 4.369 4.597 4.789 6.111 6.183 6.499 -Operating weight TR kg 3.409 3.763 4.198 4.498 4.832 5.100 6.264 6.365 6.679 7.047
Physical features
SyScroll 400-900 Air EVO CO HT 400 450 490 530 600 670 750 800 850 -Nominal cooling capacity1 kW 411,2 455,8 497,3 543,1 607,2 678,7 768,3 820,5 867,0 -Input power1 kW 123,4 138,4 152,2 167,3 186,4 208,9 234,2 249,2 265,0 -EER1 / Energy efficiency class 3,33/A 3,29/A 3,27/A 3,25/A 3,26/A 3,25/A 3,28/A 3,29/A 3,27/A -ESEER 4,44 4,47 4,53 4,34 4,36 4,48 4,33 4,30 4,34 -
SEER2 4,8 4,83 4,83 4,83 4,88 4,85 4,7 4,63 4,9 -
hsc2 189 190 190 190 192 191 185 182 193 -
SEER2 4,8 4,83 4,83 4,83 4,88 4,85 4,7 4,63 4,9 -
hsc2 189 190 190 190 192 191 185 182 193 -
Sound power level3 dB(A) 93 93 94 94 94 95 96 96 96 -Sound pressure level at 10 m4 dB(A) 60 61 60 61 61 61 62 62 62 -
SyScroll 400-900 Air EVO CO S 400 450 490 530 600 670 750 800 850 -Nominal cooling capacity1 kW 396,0 440,4 480,4 524,8 585,3 651,7 743,4 792,2 838,6 -Input power1 kW 127,2 141,4 156,0 171,4 192,0 215,6 238,6 254,6 269,6 -EER1 / Energy efficiency class 3,11/A 3,11/A 3,08/B 3,06/B 3,05/B 3,02/B 3,12/A 3,11/A 3,11/A -ESEER 4,31 4,30 4,44 4,31 4,28 4,34 4,23 4,22 4,27 -EER*1/ Energy efficiency class 3,20/A 3,21/A 3,17/A 3,15/A 3,13/A 3,10/A 3,20/A 3,19/A 3,20/A -ESEER* 4,47 4,44 4,55 4,43 4,41 4,47 4,41 4,39 4,44 -
SEER2/ hsc2 4,53/178 4,63/182 4,58/180 4,8/189 4,8/189 4,72/186 4,72/186 4,72/186 4,78/188 -
SEER*2/ hsc*2 4,7/185 4,8/189 4,75/187 5,05/199 5,05/199 4,95/195 4,95/195 4,9/193 5/197 -
SEER2/ hsc2 4,53/178 4,63/182 4,58/180 4,8/189 4,8/189 4,72/186 4,72/186 4,72/186 4,78/188 -
SEER*2/ hsc*2 4,7/185 4,8/189 4,75/187 5,05/199 5,05/199 4,95/195 4,95/195 4,9/193 5/197 -
Sound power level3 dB(A) 86 87 87 87 88 88 89 89 89 -Sound pressure level at 10 m4 dB(A) 54 54 54 54 55 55 56 56 56 -
SyScroll 400-900 Air EVO TR 400 450 490 530 600 670 750 800 850 900Nominal cooling capacity5 kW 398,8 446,1 487,7 533,9 597,1 667,3 748,3 797,9 847,2 896,7Input power5 kW 128,6 142,8 157,1 172,1 192,1 215,0 241,7 257,4 272,4 286,7EER5 3,10 3,12 3,10 3,10 3,11 3,10 3,10 3,10 3,11 3,13Heat recovery capacity kW 513,1 566,1 620,1 679,2 760,3 851,7 957,9 1.026,6 1.082,3 1.137,6
SyScroll 400-900 Air EVO CO 400 450 490 530 600 670 750 800 850 900
DimensionsLength _ / EC / HPF / TR mm 4.580 5.620 6.680 6.680 7.760 7.760 8.900 8.900 9.950 11.000Length S / EC S / HT mm 5.620 6.680 7.760 7.760 8.800 8.800 11.000 11.000 12.050 -Width mm 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175Width TR mm 3.409 3.763 4.198 4.498 4.832 5.100 6.264 6.365 6.679 7.047Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
ErP20182021
ErP20182018
ErP20182021
ErP20182018
ErP20182021
ErP20182018
| Air cooled Chiller & Heat Pump46
Air Cooled ChillerSyScroll 240-660 Air CO
Technical features 10 sizes Cooling capacity from 238,1 to 654,2 kW 3 versions:
STD (Standard) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
“Brine” version: Cooling only for process application LWT -10°C
Two refrigerant circuits Plate evaporator (AISI 316) 3/4/5/6 Scroll compressors Electronic expansion valve Microchannel coils E-Coating coil treatment as standard
1 Voltage 400V +/- 10%.* For Liquid outlet temperature <0 °C provide Brine Version (available for CO; upon request for HP).
SyScroll 240-660 Air CO
Chilled liquid
Liquid outlettemperature
Water °C from +6 to +18Water with glycol* °C from -10 to +6Temperature spread K from 3 to 7
Maximum operating pressure bar 6
Ambient air
Air enteringtemperature cooling
- °C from +10 to +45L °C from +7 to +43S °C from -14 to +43HT-HPF °C from -18 to +47
Externalstatic pressure
Standard fans Pa 0High pressure fans (HPF) Pa < 120
Power supply voltage1 V/Ph/Hz 400/3/50 (Nominal)
238-654 kW Plate
Air cooled Scroll
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard for S version) Desuperheater and total heat recovery (TR version) Hydrokit with 1 or 2 pumps with or without buffer tank Overload protection for compressors Mechanical gauges Pressostatic fan speed control (standard for S version) Power factor corrector capacitors Sequence phases control (standard) Softstart Unit protection grilles Water flow switch Water differential pressure switch (standard) Water filter
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 47
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SyScroll 240-660 Air CO (STD-EC-HPF) 240 270 290 320 360 420 470 540 590 660Nominal cooling capacity1 kW 238,1 267,4 287,4 316,1 362,0 414,2 469,6 533,7 588,9 654,2Input power1 kW 83,8 99,0 103,4 111,6 128,3 148,7 160,9 183,9 198,1 221,6EER1 / Energy efficiency class 2,84/C 2,70/C 2,78/C 2,83/C 2,82/C 2,78/C 2,92/B 2,90/B 2,97/B 2,95/BESEER 3,75 3,62 3,80 3,89 3,93 3,95 4,01 3,87 4,01 3,98EER* / EER** 2,87/2,7 2,73/2,6 2,8/2,64 2,86/2,7 2,85/2,7 2,82/2,6 2,95/2,8 2,93/2,8 3,0/2,83 2,99/2,8ESEER* / ESEER** 3,84/3,4 3,69/3,3 3,89/3,4 3,98/3,5 4,0/3,55 4,0/3,57 4,1/3,64 3,95/3,5 4,1/3,66 4,1/3,73SEER2 3,93 3,8 3,85 3,98 3,93 4,18 4,13 4,38 4,4 4,43
hsc2 154 149 151 156 154 164 162 172 173 174
SEER* / SEER**2 4 3,88 3,93 4,05 4 4,2 4,1 4,47 4,47 4,43
hsc* / hsc
**2 157 152 154 159 157 165 161 176 176 174Sound power level3 dB(A) 93 93 94 94 94 95 95 96 96 97Sound pressure level at 10 m4 dB(A) 61 61 62 62 62 63 63 64 64 64
Technical performance
SyScroll 240-660 Air CO L 240 270 290 320 360 420 470 540 590 660Nominal cooling capacity1 kW 230,0 256,9 277,6 303,8 348,5 398,6 451,7 513,1 566,5 628,8Input power1 kW 85,1 101,5 104,9 113,9 131,1 151,6 164,2 187,5 202,2 225,9EER1 / Energy efficiency class 2,70/C 2,53/D 2,65/D 2,67/D 2,66/D 2,63/D 2,75/C 2,74/C 2,80/C 2,78/CESEER 3,83 3,60 3,73 3,82 3,99 4,03 4,07 3,89 4,01 3,99SEER2 3,93 3,8 3,85 3,95 3,98 4,18 4,1 4,25 4,3 4,4
hsc2 154 149 151 155 156 164 161 167 169 173
Sound power level3 dB(A) 88 88 89 89 90 91 91 91 92 92Sound pressure level at 10 m4 dB(A) 56 56 57 57 58 59 59 59 59 59
SyScroll 240-660 Air CO S 240 270 290 320 360 420 470 540 590 660Nominal cooling capacity1 kW 214,4 236,9 259,0 280,6 323,0 368,9 418,3 474,2 524,1 580,9Input power1 kW 91,0 109,9 112,0 122,6 141,3 162,9 176,6 201,5 217,3 242,5EER1 / Energy efficiency class 2,36 /E 2,16/F 2,31/E 2,29/F 2,29/F 2,26/F 2,37/E 2,35/E 2,41/E 2,40/EESEER 3,61 3,42 3,57 3,59 3,82 3,88 3,90 3,68 3,99 3,99SEER2 3,85 3,83 3,83 3,83 3,88 4,22 4,13 4,22 4,4 4,2
hsc2 151 150 150 150 152 166 162 166 173 165
Sound power level3 dB(A) 85 86 87 87 88 88 89 89 90 90Sound pressure level at 10 m4 dB(A) 53 54 55 55 56 56 57 57 57 57
SyScroll 240-660 Air TR 240 270 290 320 360 420 470 540 590 660Nominal cooling capacity1 kW 233,7 266,1 280,1 321,2 365,4 413,9 474,9 535,1 596,3 659,2Input power1 kW 85,5 100,5 105,2 113,9 131,3 151,7 169,1 189,9 207,3 228,3EER1 2,93 2,83 2,74 3,17 3,10 2,97 3,23 3,12 3,29 3,21Total heat rejection1 313,4 360,3 382,5 422,6 483,2 553,3 622,0 706,5 777,7 864,9
Water Connections (Evaporator)Type Male gas threaded VictaulicInlet/outlet diameter inch 3” 3” 3” 3” 4” 4” 4” 4” 5” 5”WeightOperating weight - / S / L kg 1.786 1.787 1.879 1.945 2.330 2.441 2.934 3.047 3.456 3.553Operating weight TR kg 1.946 1.947 2.039 2.160 2.554 2.665 3.218 3.331 3.793 9.889DimensionsLength mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
Physical featuresSyScroll 240-660 Air CO 240 270 290 320 360 420 470 540 590 660
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.* Unità alta temperatura (HT) con ventilatori inverter.** HPF Units with high static pressure fans.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump48
Air Cooled ChillerSyScrew 370-1250 Air EVO CO
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressor stepless control Desuperheater and total heat recovery (TR) Hydrokit with 1 or 2 pumps Mechanical gauges Pressostatic fan speed control Power factor corrector capacitors Sequence phases control (standard) Softstart Unit protection grilles Water filter Water flow switch
SyScrew 370-1250 Air EVO CO
Leaving water temperature
Water °С from +5 to +15Water + glycol °С from 0 to +15Water + glycol (Brine Version) °С from -8 to +15∆ T K from 3 to 8
Air temperature
- °С from 0 to +49L/S °С from 0 to +47HT °С from -10 a +51
Minimum Air temperature Polar Version °C -18
External static pressureStandard fans Pа 0Inverter fans Pа < 120
Power supply V/Ph/Hz 400/3/50 (Nominal)
360-1.250 kW Shell & Tube
Air cooled Screw
R134a
Technical features 13 sizes Cooling capacity from 360 to 1.250 kW 3 acoustic versions:
- (Basic Low Noise) L (Low Noise) S (Super Low Noise)
Two refrigerant circuits Two Screw compressors One S&T evaporator Electronic expansion valve “Brine” version for process application LWT -8°C “Polar” version for air temperature -18°C E-Coating coil treatment as standard
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
R513A
NEW Refrigerant R513A
Air cooled Chiller & Heat Pump | 49
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SyScrew 370-700 Air EVO CO R134a (STD) 370 400 450 500 570 650 700Cooling capacity1 kW 364,1 414,5 445,5 502,9 562,1 625,5 712,9Power input1 kW 112,7 130,4 143,5 159,9 176,5 197,7 223,5EER1 / Energy efficiency class 3,23/A 3,18/A 3,11/A 3,15/A 3,18/A 3,16/A 3,19/AESEER 4,07 3,96 3,86 3,92 3,95 3,93 3,96SEER2 4,13 4,13 4,13 4,13 4,13 4,13 4,13
hsc2 162 162 162 162 162 162 162
Sound power level3 dB(A) 97 98 98 98 99 99 99Sound pressure level at 10 m4 dB(A) 65 66 66 66 67 67 67
Technical performance
SyScrew 370-700 Air EVO CO R134a L 370 400 450 500 570 650 700Cooling capacity1 kW 354,6 401,7 438,5 478,8 547,5 610,5 702,3Power input1 kW 111,8 126,4 142,5 159,0 176,4 199,6 224,3EER1 / Energy efficiency class 3,17/A 3,18/A 3,08/B 3,01/B 3,10/A 3,06/B 3,13/AESEER 4,07 4,19 4,07 4,00 4,11 4,05 4,14SEER2 4,22 4,28 4,25 4,2 4,2 4,1 4,1
hsc2 166 168 167 165 165 161 161
Sound power level3 dB(A) 91 92 92 92 93 93 94Sound pressure level at 10 m4 dB(A) 59 60 60 60 61 61 61
SyScrew 370-700 Air EVO CO R134a S 370 400 450 500 570 650 700Cooling capacity1 kW 354,6 401,7 438,5 478,8 547,5 610,5 702,3Power input1 kW 111,8 126,4 142,5 159,0 176,4 199,6 224,3EER1 / Energy efficiency class 3,17/A 3,18/A 3,08/B 3,01/B 3,10/A 3,06/B 3,13/AESEER 4,07 4,19 4,07 4,00 4,11 4,05 4,14SEER2 4,1 4,1 4,13 4,13 4,13 4,13 4,13
hsc2 161 161 162 162 162 162 162
Sound power level3 dB(A) 87 88 88 88 89 89 90Sound pressure level at 10 m4 dB(A) 55 56 56 56 57 57 58
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Physical features
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 6" 6" 6" 8" 8" 8" 8"WeightOperating weight - / L kg 3.590 4.000 4.000 4.850 5.150 5.350 5.690Operating weight S kg 3.675 4.095 4.095 4.945 5.235 5.430 5.775DimensionsLength mm 4.600 5.700 5.700 5.700 6.700 6.700 7.800Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200Height - / L mm 2.510 2.510 2.510 2.510 2.510 2.510 2.510Height S mm 2.610 2.610 2.610 2.610 2.610 2.610 2.610
SyScrew 370-700 Air EVO CO R134a 370 400 450 500 570 650 700
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump50
Physical features
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 8" 8" 8" 10" 10" 10"WeightOperating weight - / L kg 6.600 6.930 7.780 8.280 8.610 8.970Operating weight S kg 6.685 7.015 7.865 8.370 8.700 9.070DimensionsLength mm 7.800 8.800 9.900 10.900 12.000 13.000Width mm 2.200 2.200 2.200 2.200 2.200 2.200Height - / L mm 2.510 2.510 2.510 2.510 2.510 2.510Height S mm 2.610 2.610 2.610 2.610 2.610 2.610
SyScrew 750-1250 Air EVO CO R134a 750 850 950 1000 1100 1250
SyScrew 750-1250 Air EVO CO R134a (STD) 750 850 950 1000 1100 1250Cooling capacity1 kW 749,2 839,0 961,8 1.019,0 1.117,9 1.249,1Power input1 kW 237,4 261,2 288,6 312,8 340,0 394,0EER1 / Energy efficiency class 3,16/A 3,21/A 3,33/A 3,26/A 3,29/A 3,17/AESEER 3,91 3,96 4,14 4,11 4,08 3,95SEER2 4,13 4,1 4,13 4,13 4,18 4,22
hsc2 162 161 162 162 164 166
Sound power level3 dB(A) 100 100 101 101 102 103Sound pressure level at 10 m4 dB(A) 67 67 68 68 69 70
SyScrew 750-1250 Air EVO CO R134a L 750 850 950 1000 1100 1250Cooling capacity1 kW 722,2 814,4 922,4 981,4 1.086,0 1.213,9Power input1 kW 237,7 264,2 288,3 309,8 339,3 395,4EER1 / Energy efficiency class 3,04/B 3,08/B 3,20/A 3,17/A 3,20/A 3,07/BESEER 4,04 4,08 4,23 4,21 4,24 4,06SEER2 4,1 4,1 4,1 4,18 4,22 4,38
hsc2 161 161 161 164 166 172
Sound power level3 dB(A) 94 94 95 95 96 97Sound pressure level at 10 m4 dB(A) 61 61 62 62 63 64
SyScrew 750-1250 Air EVO CO R134a S 750 850 950 1000 1100 1250Cooling capacity1 kW 722,2 814,4 922,4 981,4 1.086,0 1.213,9Power input1 kW 237,7 264,2 288,3 309,8 339,3 395,4EER1 / Energy efficiency class 3,04/B 3,08/B 3,20/A 3,17/A 3,20/A 3,07/BESEER 4,04 4,08 4,23 4,21 4,24 4,06SEER2 4,13 4,13 4,1 4,13 4,13 4,25
hsc2 162 162 161 162 162 167
Sound power level3 dB(A) 90 90 91 91 92 93Sound pressure level at 10 m4 dB(A) 57 57 58 58 59 60
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical performance
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Air cooled Chiller & Heat Pump | 51
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SyScrew 370-700 Air EVO CO R513A (STD) 370 400 450 500 570 650 700Cooling capacity1 kW 360,4 410,4 441,1 497,9 556,4 619,2 705,8Power input1 kW 118,6 137,3 151,0 168,2 186,1 208,5 235,3EER1 / Energy efficiency class 3,04/B 2,99/B 2,92/B 2,96/B 2,99/B 2,97/B 3,00/BESEER 4,09 3,98 3,88 3,94 3,97 3,94 3,98SEER2 4,10 4,10 4,10 4,10 4,10 4,10 4,10
hsc2 161 161 161 161 161 161 161
Sound power level3 dB(A) 97 98 98 98 99 99 99Sound pressure level at 10 m4 dB(A) 65 66 66 66 67 67 67
Technical performance
SyScrew 370-700 Air EVO CO R513A L 370 400 450 500 570 650 700Cooling capacity1 kW 351,1 397,7 434,2 474,0 542,0 604,4 695,2Power input1 kW 117,8 133,0 149,7 167,5 186,3 209,9 236,5EER1 / Energy efficiency class 2,98/B 2,99/B 2,90/B 2,83/C 2,91/B 2,88/C 2,94/BESEER 4,09 4,20 4,09 4,02 4,12 4,06 4,16SEER2 4,14 4,20 4,18 4,13 4,13 4,10 4,10
hsc2 163 165 164 162 162 161 161
Sound power level3 dB(A) 91 92 92 92 93 93 94Sound pressure level at 10 m4 dB(A) 59 60 60 60 61 61 61
SyScrew 370-700 Air EVO CO R513A S 370 400 450 500 570 650 700Cooling capacity1 kW 354,6 401,7 438,5 478,8 547,5 610,5 702,3Power input1 kW 117,8 133,0 149,7 167,5 186,3 209,9 236,5EER1 / Energy efficiency class 2,98/B 2,99/B 2,90/B 2,83/C 2,91/B 2,88/C 2,94/BESEER 4,09 4,20 4,09 4,02 4,12 4,06 4,16SEER2 4,10 4,10 4,10 4,10 4,10 4,10 4,10
hsc2 161 161 161 161 161 161 161
Sound power level3 dB(A) 87 88 88 88 89 89 90Sound pressure level at 10 m4 dB(A) 55 56 56 56 57 57 58
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Physical features
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 6" 6" 6" 8" 8" 8" 8"WeightOperating weight - / L kg 3.590 4.000 4.000 4.850 5.150 5.350 5.690Operating weight S kg 3.675 4.095 4.095 4.945 5.235 5.430 5.775DimensionsLength mm 4.600 5.700 5.700 5.700 6.700 6.700 7.800Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200Height - / L mm 2.510 2.510 2.510 2.510 2.510 2.510 2.510Height S mm 2.610 2.610 2.610 2.610 2.610 2.610 2.610
SyScrew 370-700 Air EVO CO R513A 370 400 450 500 570 650 700
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
New
| Air cooled Chiller & Heat Pump52
Physical features
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 8" 8" 8" 10" 10" 10"WeightOperating weight - / L kg 6.600 6.930 7.780 8.280 8.610 8.970Operating weight S kg 6.685 7.015 7.865 8.370 8.700 9.070DimensionsLength mm 7.800 8.800 9.900 10.900 12.000 13.000Width mm 2.200 2.200 2.200 2.200 2.200 2.200Height - / L mm 2.510 2.510 2.510 2.510 2.510 2.510Height S mm 2.610 2.610 2.610 2.610 2.610 2.610
SyScrew 750-1250 Air EVO CO R513A 750 850 950 1000 1100 1250
SyScrew 750-1250 Air EVO CO R513A (STD) 750 850 950 1000 1100 1250Cooling capacity1 kW 740,8 829,4 952,1 1008,8 1106,7 1236,6Power input1 kW 251,1 276,5 304,2 329,7 358,2 415,0EER1 / Energy efficiency class 2,95/B 3,00/B 3,13/B 3,06/B 3,09/B 2,98/BESEER 3,93 3,98 4,16 4,12 4,10 3,97SEER2 4,10 4,10 4,10 4,10 4,10 4,13
hsc2 161 161 161 161 161 162
Sound power level3 dB(A) 100 100 101 101 102 103Sound pressure level at 10 m4 dB(A) 67 67 68 68 69 70
SyScrew 750-1250 Air EVO CO R513A L 750 850 950 1000 1100 1250Cooling capacity1 kW 714,9 806,3 913,2 971,6 1075,2 1201,7Power input1 kW 250,0 278,0 303,4 326,0 357,2 415,9EER1 / Energy efficiency class 2,86/C 2,90/B 3,01/B 2,98/B 3,01/B 2,89/CESEER 4,05 4,09 4,25 4,22 4,25 4,07SEER2 4,10 4,10 4,10 4,10 4,15 4,28
hsc2 161 161 161 161 163 168
Sound power level3 dB(A) 94 94 95 95 96 97Sound pressure level at 10 m4 dB(A) 61 61 62 62 63 64
SyScrew 750-1250 Air EVO CO R513A S 750 850 950 1000 1100 1250Cooling capacity1 kW 722,2 814,4 922,4 981,4 1.086,0 1.213,9Power input1 kW 250,0 278,0 303,4 326,0 357,2 416,0EER1 / Energy efficiency class 2,86/C 2,90/B 3,01/B 2,98/B 3,01/B 2,89/CESEER 4,05 4,09 4,25 4,22 4,25 4,07SEER2 4,10 4,10 4,10 4,10 4,10 4,18
hsc2 161 161 161 161 161 164
Sound power level3 dB(A) 90 90 91 91 92 93Sound pressure level at 10 m4 dB(A) 57 57 58 58 59 60
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Technical performance
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
New
Air cooled Chiller & Heat Pump | 53
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Keep it cool.With Systemair Air Conditioning system.
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
| Air cooled Chiller & Heat Pump54
Air Cooled ChillerSyScrew 300-1400 Air CO
Technical features 21 sizes Cooling capacity from 295 to 1.395 kW 2 versions:
STD (Standard) HT (High Temperature)
3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
Two refrigerant circuits Screw compressors Electronic expansion valve “Brine” version for process application LWT-8°C “Polar” version for air temperature -18°C E-Coating coil treatment as standard
SyScrew 300-1400 Air CO
Leaving water temperature
Water °С from +5 to +15Water + glycol °С from 0 to +15Water + glycol (Brine Version) °С from -8 to +15∆ T K from 3 to 8
Air temperature
- °С from 0 to +48L °С from 0 to +46S °С from -10 to +42HT °С from -10 to +50Minimum Air temperature Polar Version °C -18
External static pressureStandard fans Pа 0Inverter fans Pа < 120
Power supply V/Ph/Hz 400/3/50 (Nominal)
295-1.395 kW Shell & Tube
Air cooled Screw
R134a
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors stepless control Desuperheater and total heat recovery Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 55
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScrew 300-580 Air CO (STD) 300 360 410 450 480 500 540 580Cooling capacity1 kW 295 365 413 445 480 505 540 575Power input1 kW 108,8 134,4 151,5 167,7 176,3 184,1 198,6 212,5EER1 / Energy efficiency class 2,71/C 2,71/C 2,73/C 2,65/D 2,72/C 2,74/C 2,72/C 2,70/CESEER 3,32 3,15 3,16 3,18 3,27 3,18 3,26 3,14SEER2 2,76 2,63 3,21 3,13 3,02 3,03 2,91 3,22Sound power level3 dB(A) 95 96 97 97 97 97 98 98Sound pressure level at 10 m4 dB(A) 63 64 65 65 65 65 66 65
SyScrew 300-580 Air CO L 300 360 410 450 480 500 540 580Cooling capacity1 kW 283 357 405 436 470 495 529 563Power input1 kW 102,5 133,4 149,2 166,0 174,9 183,0 197,1 210,5EER1 / Energy efficiency class 2,76/D 2,68/D 2,72/C 2,63/D 2,69/D 2,70/C 2,68/D 2,68/DESEER 3,42 3,32 3,37 3,37 3,45 3,35 3,45 3,32SEER2 3,05 2,91 3,5 3,41 3,22 3,24 3,09 3,35Sound power level3 dB(A) 89 90 91 91 91 91 92 92Sound pressure level at 10 m4 dB(A) 57 58 59 59 59 59 60 59
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers. 3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
SyScrew 300-580 Air CO S 300 360 410 450 480 500 540 580Cooling capacity1 kW 276 339 385 414 446 469 502 535Power input1 kW 105,7 140,4 157,0 174,7 184,1 192,8 207,6 221,6EER1 / Energy efficiency class 2,61/D 2,42/E 2,45/E 2,37/E 2,43/E 2,43/E 2,42/E 2,41/EESEER 3,24 3,14 3,18 3,18 3,26 3,16 3,25 3,13SEER2 2,96 2,82 2,82 3,39 3,31 3,12 3,13 3,02Sound power level3 dB(A) 85 86 87 87 87 87 88 88Sound pressure level at 10 m4 dB(A) 53 54 55 55 55 55 56 55
Water connection (Evaporator)Type VictaulicInlet/outlet diameter inch 5” 5” 6” 6” 6” 6” 6” 6”WeightOperating weight - / L/ HT kg 3.270 3.300 3.670 3.990 4.290 4.320 4.550 4.800Operating weight S kg 3.350 3.380 3.760 4.080 4.390 4.410 4.640 4.900DimensionsLength mm 4.600 4.600 4.600 4.600 4.600 4.600 5.700 6.700Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200 2.200Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550 2.550
Physical features
SyScrew 300-580 Air CO 300 360 410 450 480 500 540 580
SyScrew 300-580 Air CO HT 300 360 410 450 480 500 540 580Cooling capacity1 kW 301 372 422 454 489 515 550 586Power input1 kW 106,7 138,1 156,9 172,8 181,2 188,8 204,1 218,8EER1 / Energy efficiency class 2,82/C 2,69/D 2,69/D 2,63/D 2,70/C 2,73/C 2,70/D 2,68/DESEER 3,27 3,12 3,12 3,15 3,24 3,16 3,24 3,11SEER2 2,84 2,71 3,28 3,19 3,07 3,08 2,96 3,25Sound power level3 dB(A) 101 102 103 103 103 103 104 104Sound pressure level at 10 m4 dB(A) 69 70 71 71 71 71 72 71
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump56
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water connection (Evaporator)Type VictaulicInlet/outlet diameter inch 6” 6” 8” 8” 8” 8” 8”WeightOperating weight - / L / HT kg 5.330 5.760 6.220 6.750 6.830 7.090 7.180Operating weight S kg 5.430 5.860 6.320 6.850 6.930 7.190 7.280DimensionsLength mm 6.700 6.700 6.700 8.800 8.800 8.800 8.800Width mm 2.200 2.200 2.200 2.200 2.200 2.200 2.200Height mm 2.550 2.550 2.550 2.550 2.550 2.550 2.550
SyScrew 650-1000 Air CO S 650 720 800 850 910 970 1000Cooling capacity1 kW 606 663 738 792 846 903 938Power input1 kW 246,1 264,3 286,3 311,6 335,0 356,1 366,0EER1 / Energy efficiency class 2,46/E 2,51/D 2,58/D 2,54/D 2,53/D 2,54/D 2,56/DESEER 3,20 3,37 3,47 3,42 3,28 3,41 3,33SEER2 3,26 3,26 3,27 3,33 3,32 3,33 3,29Sound power level3 dB(A) 89 89 89 89 90 90 90Sound pressure level at 10 m4 dB(A) 56 56 56 56 57 57 57
SyScrew 650-1000 Air CO HT 650 720 800 850 910 970 1000Cooling capacity1 kW 665 727 809 868 927 990 1.028Power input1 kW 244,7 261,0 285,0 307,7 328,7 349,6 360,6EER1 / Energy efficiency class 2,72/C 2,79/C 2,84/C 2,82/C 2,82/C 2,83/C 2,85/CESEER 3,15 3,34 3,41 3,39 3,27 3,40 3,31SEER2 3,24 3,23 3,25 3,28 3,27 3,28 3,27Sound power level3 dB(A) 105 105 105 106 106 106 106Sound pressure level at 10 m4 dB(A) 72 72 72 73 73 73 73
SyScrew 650-1000 Air CO 650 720 800 850 910 970 1000
SyScrew 650-1000 Air CO (STD) 650 720 800 850 910 970 1000Cooling capacity1 kW 652 713 794 851 909 971 1.008Power input1 kW 236,8 253,4 275,7 298,9 320,2 340,5 350,7EER1 / Energy efficiency class 2,75/C 2,81/C 2,88/C 2,85/C 2,84/C 2,85/C 2,87/CESEER 3,19 3,38 3,45 3,42 3,29 3,42 3,33SEER2 3,22 3,22 3,23 3,22 3,22 3,23 3,25Sound power level3 dB(A) 99 99 99 100 100 100 100Sound pressure level at 10 m4 dB(A) 66 66 66 67 67 67 67
Technical performance
Physical features
SyScrew 650-1000 Air CO L 650 720 800 850 910 970 1000Cooling capacity1 kW 639 699 778 835 891 952 988Power input1 kW 233,7 250,9 272,0 296,0 318,2 338,2 347,8EER1 / Energy efficiency class 2,73/C 2,78/C 2,86/C 2,82/C 2,80/C 2,81/C 2,84/CESEER 3,39 3,58 3,67 3,62 3,48 3,61 3,52SEER2 3,29 3,37 3,31 3,44 3,43 3,44 3,4Sound power level3 dB(A) 93 93 93 94 94 94 94Sound pressure level at 10 m4 dB(A) 60 60 60 61 61 61 61
Air cooled Chiller & Heat Pump | 57
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Physical features
Water connection (Evaporator)Type VictaulicInlet/outlet diameter inch 8” 8” 8” 8” 10” 10”WeightOperating weight - / L / HT kg 7.880 8.150 8.350 8.560 8.940 9.245Operating weight S kg 7.980 8.250 8.450 8.660 9.040 9.345DimensionsLength mm 9.900 10.900 10.900 10.900 12.000 13.000Width mm 2.200 2.200 2.200 2.200 2.200 2.200Height mm 2.550 2.550 2.550 2.550 2.550 2.550
SyScrew Air 1070-1400 Air CO S 1070 1130 1170 1200 1300 1400Cooling capacity1 kW 996 1.053 1.090 1.133 1.224 1.324Power input1 kW 388,5 409,3 428,7 450,2 485,8 511,3EER1 / Energy efficiency class 2,56/D 2,57/D 2,54/D 2,52/D 2,52/D 2,59/DESEER 3,45 3,34 3,42 3,27 3,27 3,22SEER2 3,28 3,39 3,24 3,26 3,26 3,26Sound power level3 dB(A) 90 91 91 91 92 93Sound pressure level at 10 m4 dB(A) 57 58 58 58 59 60
SyScrew 1070-1400 Air CO HT 1070 1130 1170 1200 1300 1400Cooling capacity1 kW 1.092 1.155 1.195 1.242 1.342 1.415Power input1 kW 382,2 402,9 422,3 443,6 479,8 494,9EER1 / Energy efficiency class 2,86/C 2,87/C 2,83/C 2,80/C 2,80/C 2,86/CESEER1 3,43 3,33 3,40 3,25 3,25 3,32SEER2 3,25 3,35 3,22 3,24 3,29 3,25Sound power level3 dB(A) 106 107 107 107 108 109Sound pressure level at 10 m4 dB(A) 73 74 74 74 75 76
SyScrew 1070-1400 Air CO 1070 1130 1170 1200 1300 1400
Technical performance
SyScrew 1070-1400 Air CO (STD) 1070 1130 1170 1200 1300 1400Cooling capacity1 kW 1.071 1.132 1.172 1.218 1.316 1.395Power input1 kW 371,8 391,8 410,5 431,2 465,9 482,6EER1 / Energy efficiency class 2,88/C 2,89/C 2,85/C 2,82/C 2,82/C 2,89/CESEER 3,46 3,35 3,43 3,28 3,28 3,35SEER2 3,24 3,3 3,26 3,22 3,23 3,22Sound power level3 dB(A) 100 101 101 101 102 103Sound pressure level at 10 m4 dB(A) 67 68 68 68 69 70
SyScrew 1070-1400 Air CO L 1070 1130 1170 1200 1300 1400Cooling capacity1 kW 1.050 1.110 1.148 1.193 1.290 1.346Power input1 kW 368,8 388,6 407,0 427,4 461,4 491,2EER1 / Energy efficiency class 2,85/C 2,86/C 2,82/C 2,79/C 2,80/C 2,74/CESEER 3,65 3,54 3,62 3,46 3,47 3,40SEER2 3,38 3,5 3,34 3,37 3,37 3,29Sound power level3 dB(A) 94 95 95 95 96 97Sound pressure level at 10 m4 dB(A) 61 62 62 62 63 64
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump58
Operating limits
Technical features 6 sizes Cooling capacity from 5,0 to 14,5 kW Heating capacity from 6,2 to 16,0 kW EER up to 3,30 SCOP up to 3,78
Product Advantages Low energy consumption EC fans Operating range:
from -5 to 46 °C cooling and from -15 to 27 °C heating DC Inverter technology: Compressor and outdoor fan motor One refrigerant circuit with DC compressor Blue fin coil LWT up to +55 °C in heating mode, outdoor temperature down
to -15 °C. Bi-flow electronic expansion valve Stainless steel plate heat exchanger with antifreeze protection Single pump with expansion tank Operating low water content in the plant
Inverter Air Cooled Heat PumpMini SysAqua DCI 5-16
5-14,5 kW
Rotary InverterR410A
6,2-16 kW
Automatic circuit breaker Coil guards Fan speed control Sequence phases control Softstart Water differential pressure switch (sizes 10 to 16 only) Water flow switch (sizes 5 and 7 only)
Accessories and options ON/OFF remote control (available for sizes 10 to 16 only)
Mini SysAqua DCI 5-16Leaving water temperature (Cooling mode) °C from 4 to 20Air temperature (Cooling mode) °C from -5 to 46Leaving water temperature (Heating mode) °C from 30 to 55Air temperature (Heating mode) °C from -15 to 27
Power supply V/ph/Hz230/1/50 5 - 7 -10 (Nominal)
400/3/50 12 - 14 -16 (Nominal)
Plate
Air cooled
ErP20182017
EC Motor
Air cooled Chiller & Heat Pump | 59
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Mini SysAqua DCI 5 7 10 12 14 16
Cooling
Cooling Capacity1 kW 5,0 7,0 10,0 11,2 12,5 14,5Power input1 kW 1,55 2,25 2,95 3,38 3,90 4,70EER1 3,23 3,11 3,39 3,31 3,20 3,10Energy efficiency class (EER)1 A A A A A A
Heating
Heating Capacity2 kW 6,20 8,0 11,0 12,3 13,8 16,0Power input2 kW 1,90 2,50 3,14 3,72 4,25 4,85SCOP3 3,55 3,46 3,34 3,66 3,78 3,39Energy efficiency class (SCOP)3 A+ A+ A+ A+ A+ A+
hsh3 138,9 135,3 130,7 143,5 148,3 132,6
Sound power level dB(A) 63 66 68 68 70 72
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.3 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.
Water connection (Evaporator)Connection type Male gas threadedInlet/Outlet Diameter inch 1" 1" 1” 1/4 1” 1/4 1” 1/4 1” 1/4WeightOperating weight kg 81 81 110 110 111 111DimensionsLength mm 990 990 970 970 970 970Width mm 354 354 400 400 400 400Height mm 966 966 1.327 1.327 1.327 1.327
Physical features
Technical performance
Mini SysAqua DCI 5 7 10 12 14 16
| Air cooled Chiller & Heat Pump60
* Below 5°C, glycol is required. For operation below 0°C contact sales office.
Chillers suitable for operation without buffer tank for water content greater than 2,5 liters of water per kW of output.
Technical features 2 sizes Cooling capacity from 20,0 to 35,9 kW Heating capacity from 20,4 to 34,0 kW Operating range:
from -10 to 45 °C cooling and from -15 to 20 °C heating Inverter driven compressor Plate evaporator (AISI 316) A single inverter driven 3-phase scroll compressor equipped
with brushless motor with variable frequency (20-120 Hz) One refrigerant circuit Bi-flow electronic expansion valve Multistage centrifugal pump as standard Bluefin coil Operating low water content in the plant
Inverter Air Cooled Heat PumpSyScroll 20-30 Air EVO HP
20-36 kW
Plate
Air cooled
Scroll InverterR410A
20-34 kW
SyScroll 20-30 Air EVO HPLeaving water temperature (Cooling mode)* °C from -8 to 18∆ T water (Cooling mode) K from 3 to 7Air temperature (Cooling mode) °C from -10 to 45Leaving water temperature (Heating mode)* °C from 25 to 55∆ T water (Heating mode) K from 3 to 7Air temperature (Heating mode) °C from -15 to 20Power supply V/ph/Hz 400/3+N/50 (Nominal)
Accessories and options Automatic circuit breaker (standard) Buffer tank placed under unit Coils treatments Coil grilles (standard) Fan speed control (standard) In/Out Valve kit Power factor corrector capacitors (standard) Remote on/off Sequence phases control (standard) Softstart (standard) Water differential pressure switch (standard) Water filter (standard) & Water flow switch
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 61
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performanceSyScroll 20-30 Air EVO HP 20 30
Cooling
Cooling Capacity (min/nom/max)2 kW 9,33 20,0 28,0 13,9 29,0 35,9Power input2 kW 2,38 4,15 6,61 3,51 7,24 13,0EER2 3,92 4,82 4,24 3,96 4,01 2,76Energy efficiency class A ACooling Capacity (min/nom/max)4 kW 6,60 20,0 25,2 9,43 29,0 31,1Power input4 kW 2,52 6,65 10,3 3,14 10,7 12,4EER4 2,62 3,01 2,45 3,00 2,71 2,51Energy efficiency class B CEER 75% 3,83 3,65EER 50% 4,53 4,48EER 25% 3,80 4,79ESEER 4,08 4,23SEER5 3,75 4,075
hsc5 147 160
Heating
Heating Capacity (min/nom/max)1 kW 9,94 20,4 29,4 11,5 26,1 34,0Power input1 kW 2,98 5,02 8,37 3,01 6,45 9,80COP1 3,34 4,06 3,51 3,82 4,05 3,47Eurovent class A AHeating Capacity (min/nom/max)3 kW 8,90 20,4 27,4 10,2 26,1 33,5Power input3 kW 3,34 6,44 9,64 3,97 8,42 11,6COP3 2,66 3,17 2,84 2,57 3,10 2,89Energy efficiency class B BSCOP / Energy efficiency class6 3,43 / A+ 3,57 / A+
hsh6 134 140
Sound power level7 dB(A) 74 75Sound pressure level at 10 m8 dB(A) 43 44
1 Data refers to 35°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.2 Data refers to 18°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.5 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.6 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.7 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.8 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water Connections (evaporator)Type Male gas threadedInlet/Outlet Diameter inch 1” 1/4WeightOperating weight kg 260 275DimensionsLength mm 1.477 1.477Width mm 539 539Height mm 1.615 1.615
Physical features
SyScroll 20-30 Air EVO HP 20 30
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump62
Air cooled heat pump SysAqua 20-40 H
Technical features 5 sizes Cooling capacity from 19,4 to 37,4 kW Heating capacity from 19,5 to 41,6 kW EER up to 3,18 SEER up to 3,91 SCOP up to 3,40
Product Advantages Extra low sound level Refrigerant R410A Extended operating limits High temperature operation up to 50°C Heating mode operation down to -17°C Leaving hot water up to 50°C High SEER and SCOP Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop One refrigerant circuit with tandem scroll compressors for a
higher efficiency at partial load Hydraulic circuit with or without pump in standard (including a
not mounted water filter) Finned coil waterproof treatment Modbus RTU communication protocol as standard Return or leaving water temperature control Set point compensation Night mode (extra low sound level) Remote On/Off Heat Cool mode remote Water flow switch (factory mounted) Phase monitor
19-37 kW
Plate
Air cooled Scroll
20-42 kW R410A
Main accessories and options All seasons Antivibration mount rubber Antivibration spring Bacnet IP Bacnet MSTP (upon request) Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Modbus TCP/IP Nordic Pack Outdoor coil protection grid Remote control Shut off valves Sofstarter SysCloud Variable pumps Water pressure switch Water tank 100L Without neutral (upon request)
SysAqua 20-40 H
Leaving water temperature(cooling mode)
without glycol °С from 5 to 18with glycol 45% °С from -10 to 18
External air temperature (Cooling mode) °С from -10 to 50Leaving water temperature (Heating mode) °С from 20 to 50External air temperature (Heating mode) °С from -17 to 20Power supply V/ph/Hz 400/3~+N/50 (Nominal)
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
NEW Size 20 and variable pumps now available!
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere! (optional)
Air cooled Chiller & Heat Pump | 63
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 20-40 H 20 25 30 35 40
Cooling
Cooling Capacity1 kW 19,40 25,3 26,9 35,8 37,4Power input1 kW 6,10 8,61 9,34 13,49 13,64Total EER 100%1 3,18 2,94 2,88 2,65 2,74ESEER1 - 3,78 3,77 3,45 3,71Energy efficiency class (EER)1 A B C D CSEER3 3,91 3,87 3,88 3,68 3,91hsc
3 150 149 149 141 135
Heating
Heating Capacity2 kW 19,50 26,9 29,7 37,3 41,6Power input2 kW 6,11 9,28 9,93 13,23 13,51SCOP4 3,37 3,27 3,27 3,36 3,40Energy efficiency class (SCOP)4 A+ A+ A+ A+ A+hsh
4 132 128 128 132 133Sound power level5 dB(A) 75 75 75 76 76
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.3 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Following Eurovent standard.
Technical performance
Technical features
Water connection (Evaporator)Type Male gas threadedInlet/outlet diameter inch 1”1/2 1”1/2 1”1/2 1”1/2 1”1/2WeightWithout water tank - 1 pump kg 285 295 325 335 335With water tank - 1 pump kg 450 460 490 500 500DimensionsLength mm 1.000 1.000 1.000 1.000 1.000Width without water tank mm 1.000 1.000 1.000 1.000 1.000Width with water tank mm 1.507 1.507 1.507 1.507 1.507Height mm 1.983 1.983 1.983 1.983 1.983
SysAqua 20-40 H 20 25 30 35 40
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
New
| Air cooled Chiller & Heat Pump64
Technical features 6 sizes
Cooling capacity from 36,8 to 71,6 kW Heating capacity from 39,2 to 76,3 kW
3 versions: STD (Standard version)
HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions:
Standard version (STD) Super Low Noise (S) One refrigerant circuit 2 scroll compressors (one tandem) Plate evaporator (AISI 316) Low operating water content in the plant “Polar” version for extreme conditions
Air Cooled Heat PumpSyScroll 40-75 Air HP
37-72 kW
Plate
Air cooled Scroll
39-76 kW R410A
Accessories and options Automatic circuit breaker Coil grilles (standard) Coils treatments Compressors acoustic box (standard on S) Compressors jackets (standard S) Desuperheater Electric heater inside buffer tank for additional heating Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter (standard) Water flow switch (standard) Water pressure switch (standard)
SyScroll 40-75 Air HPLeaving water temperature (Cooling mode)* °C from -8 to 18Water ∆ T (Cooling mode) K from 3 to 7Leaving water temperature (Heating mode) °C from 25 to 55Water ∆ T (Heating mode) K from 3 to 15Power supply V/ph/Hz 400/3+N/50 (Nominal)
* Below 5°C, glycol and electronic expansion valve are required.
Chillers suitable for operation without buffer tank for water content greater than 4 liters of water per kW of output.
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 65
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScroll 40-75 Air HP (STD) 40 45 50 60 65 75
Cooling
Cooling capacity1 kW 36,8 41,7 48,4 56,8 64,3 71,6Power input1 kW 13,6 15,6 18,1 19,9 22,8 27,1EER1 2,71 2,67 2,67 2,85 2,82 2,64Energy efficiency class C D D C C DESEER 3,81 3,74 3,72 3,82 3,75 3,57SEER2 3,65 4,05 4,75 4,72 4,55 4,3
hsc2 143 159 187 186 179 169
Heating
Heating capacity3 kW 39,2 43,7 51,7 58,0 69,1 76,3Power input3 kW 13,3 14,5 16,3 21,3 23,0 26,9COP3 2,95 3,01 3,17 2,72 3,00 2,84Energy efficiency class C B B C B CSCOP /Energy efficiency class4 3,69 / A+ 3,68 / A+ 3,90 / A++ 3,62 / A+ 3,63 / A+ 3,61 / A+
hsh4 145 144 153 142 142 142
Sound power level5 dB(A) 78 79 79 83 84 84Sound pressure level at 10 m6 dB(A) 47 47 47 52 52 52
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
SyScroll 40-75 Air HP S 40 45 50 60 65 75
Cooling
Cooling capacity1 kW 36,8 40,2 46,3 55,0 59,8 68,9Power input1 kW 13,9 16,1 18,9 20,1 22,9 28,0EER1 2,65 2,50 2,45 2,74 2,61 2,46Energy efficiency class D D E C D EESEER 3,61 3,50 3,42 3,67 3,47 3,35SEER2 3,65 4,05 4,75 4,72 4,47 4,3
hsc2 143 159 187 186 176 169
Heating
Heating capacity3 kW 38,2 42,5 50,4 56,6 67,3 74,4Power input3 kW 13,0 14,2 16,1 20,8 22,5 26,4COP3 2,94 2,99 3,13 2,72 2,99 2,82Energy efficiency class C C B C C CSCOP /Energy efficiency class4 3,71 / A+ 3,62 / A+ 3,84 / A++ 3,65 / A+ 3,63 / A+ 3,54 / A+
hsh4 145 142 151 143 142 139
Sound power level5 dB(A) 74 75 75 78 79 79Sound pressure level at 10 m6 dB(A) 42 44 44 46 47 47
Physical features
Water connection (Evaporator)Connection type Male gas threadedInlet/outlet Diameter inch 2” 2” 2” 2” 2” 2”WeightOperating weight kg 431 440 467 517 524 530DimensionsLength mm 1.750 1.750 1.750 2.200 2.200 2.200Width mm 1.100 1.100 1.100 1.100 1.100 1.100Height mm 1.580 1.580 1.580 1.580 1.580 1.580
SyScroll 40-75 Air HP 40 45 50 60 65 75
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump66
Technical features 7 sizes Cooling capacity from 46,8 to 121,9 kW Heating capacity from 48,5 to 119,1 kW EER up to 2,98 SEER up to 4,04 SCOP up to 3,43
Product Advantages Low sound level Refrigerant R410A Extended operating limits High temperature operation up to 50°C Heating mode operation down to -17°C Leaving hot water up to 50°C High SEER and SCOP Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop One refrigerant circuit with tandem scroll compressors for a
higher efficiency at partial load Hydraulic circuit without pump in standard (including a not
mounted water filter) Finned coil waterproof treatment Modbus RTU communication protocol as standard Return or leaving water temperature control Set point compensation Night mode (extra low sound level) Remote On/Off Heat Cool mode remote Water flow switch (factory mounted) Phase monitor
47-122 kW
Plate
Scroll
48,5-119 kW
R410A
Main accessories and options All seasons Antivibration mount rubber Antivibration spring Bacnet IP Bacnet MSTP (upon request) Compatible with container transportation Extra low noise version Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Hydraulic circuit pack single or double pump Modbus TCP/IP Outdoor coil protection grid Refrigerant gauges HP/LP Remote control Shut off valves Sofstarter SysCloud Variable pumps Water pressure switch Water tank 300L Without neutral (upon request)
SysAqua 45-125 H
Leaving water temperature(cooling mode)
without glycol °С from 5 to 18with glycol 45% °С from -10 to 18
External air temperature (Cooling mode) °С from -10 to 50Leaving water temperature (Heating mode) °С from 20 to 50External air temperature (Heating mode) °С from -17 to 20Power supply V/ph/Hz 400/3~+N/50 (Nominal)
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
NEW Variable pumps now available!
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere! (optional)
Air Cooled Heat PumpSysAqua 45-125 H
Air cooled
Air cooled Chiller & Heat Pump | 67
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 45-125 H 45 55 65 75 90 105 125
Cooling
Cooling Capacity1 kW 46,8 53,3 65,8 71,6 91,4 106,2 122Power input1 kW 16,9 19,7 22,1 24,3 34,4 38,1 46,4Total EER 100%1 2,77 2,71 2,98 2,95 2,66 2,79 2,63ESSER1 3,87 3,89 4,00 3,97 3,82 3,85 3,83Energy efficiency class (EER)1 C C B B D C DSEER3 3,70 3,86 4,04 3,99 3,89 3,88 3,89hsc
3 142 148 156 153 149 149 150
Heating
Heating Capacity2 kW 48,5 58,2 67,2 75,9 88,1 101,0 119,1Power input2 kW 17,3 20,4 22,5 24,3 33,8 38,4 45,5SCOP4 3,23 3,27 3,43 3,40 3,26 3,31 3,35Energy efficiency class (SCOP)4 A+ A+ A+ A+ A+ A+ A+hsh
4 126 128 134 133 128 129 131Sound power level5 dB(A) 80 80 80 80 83 83 83
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.3 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Following Eurovent standard.
Technical performance
Water connections (evaporator)Type Male gas threaded Inlet/outlet Diameter inch 2” 2” 2” 2” 2”1/2 2”1/2 2”1/2WeightWithout water tank - 1 pump kg 545 545 615 615 795 905 925With water tank - 1 pump kg 1.005 1.005 1.075 1.075 1.225 1.365 1.385DimensionsLength without water tank mm 2.180 2.180 2.180 2.180 2.180 2.180 2.180Length with water tank mm 2.680 2.680 2.680 2.680 2.680 2.680 2.680Width mm 1.160 1.160 1.160 1.160 1.160 1.160 1.160Height mm 1.986 1.986 1.986 1.986 2.286 2.286 2.286
Physical features
SysAqua 45-125 H 45 55 65 75 90 105 125
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump68
Air Cooled Heat PumpSyScroll 85-135 Air HP
Technical feature 5 sizes
Cooling capacity from 79,0 to 125,0 kW Heating capacity from 85,0 to 132,6 kW 3 versions:
STD (Standard versions) HT (High Temperature version) HPF (High Pressure Fans version)
2 acoustic versions: Standard version (STD)
Extra Low Noise version (S) One refrigerant circuit 2 Scroll compressors (tandem) Plate evaporator Microprocessor control Electronic expansion valve as standard
SyScroll 85-135 Air HP
Leaving water temperature(cooling mode)
Water °С from 6 to 18
Water with glycol +electronic expansion valve* °С from -8 to 6
∆ T К from 3 to 7
Air temperature(cooling mode)
BLN °С from 5 to 42S °С from -14 to 40HT °С from -18 to 44
Leaving water temperature(heating mode)
Water °С from +20 to 52∆ T К from 3 to 7
Air temperature (heating mode)
BLN °С from -10 to 20S °С from -10 to 20HT °С from -12 to 20
External static pressureStandard fans P 0High pressure fans (HPF) P <120
Power supply V/ph/Hz 400/3~+N/50 (Nominal)
79-125 kW
Plate
Air cooled
Scroll
85-133 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard) Compressors jackets Coils treatments Desuperheater Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch (standard) Water pressure switch
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
* For operation below 0°C contact sales office.
Air cooled Chiller & Heat Pump | 69
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
SyScroll 85-135 Air HP 85 95 105 120 135
Cooling
Cooling capacity1 kW 79,0 87,0 98,0 113,8 125,0Power input1 kW 27,6 32,0 39,0 42,0 47,0EER1 2,86 2,72 2,51 2,71 2,66Energy efficiency class C C D C DESEER 3,84 4,22 3,75 3,98 4,00SEER2 3,28 3,33 3,28 3,63 3,65
hsc2 128 130 128 142 143
Heating
Heating capacity3 kW 85,0 96,0 107,0 120,0 132,6Power input3 kW 27,1 30,8 38,0 42,5 47,2COP3 3,14 3,12 2,82 2,82 2,81Energy efficiency class B B C C CSCOP /Energy efficiency class4 3,56 / A+ 3,51 / A+ 3,36 / A+ 3,31 / A+ 3,33 / A+
hsh4 139 137 131 129 130
Sound power level5 dB(A) 84 84 88 88 88Sound pressure level at 10 m6 dB(A) 52 52 56 56 56
SyScroll 85-135 Air HP S 85 95 105 120 135
Cooling
Cooling capacity1 kW 76,0 83,3 95,0 111,4 121,8Power input1 kW 28,3 33,3 40,0 42,6 48,0EER1 2,68 2,50 2,37 2,62 2,54Energy efficiency class D E E D DESEER 3,73 4,10 3,68 3,74 3,88SEER2 3,48 3,63 4,43 4,18 4,08
hsc2 136 142 174 164 160
Heating
Heating capacity3 kW 82,6 93,1 105,1 117,8 129,4Power input3 kW 26,4 30,1 37,0 41,5 46,2COP3 3,13 3,09 2,84 2,84 2,80Energy efficiency class B B C C CSCOP /Energy efficiency class4 3,56 / A+ 3,51 / A+ 3,36 / A+ 3,31 / A+ 3,33 / A+
hsh4 139 137 131 129 130
Sound power level5 dB(A) 82 82 85 85 85Sound pressure level at 10 m6 dB(A) 50 50 53 53 53
Physical features
Water connections (Evaporator)Type Male gas threadedInlet/outlet diameter inch 2”1/2WeightOperating weight Kg 860 932 1.064 1.170 1.214DimensionsLength mm 3.000 3.500Width mm 1.100 1.100Height mm 2.250 2.250
SyScroll 85-135 Air HP 85 95 105 120 135
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump70
Technical feature 6 sizes Cooling capacity from 81,0 to 129,6 kW Heating capacity from 87,0 to 143,6 kW 4 versions:
STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans)
2 acoustic versions: BLN (Basic Low Noise)
ELN (Extra Low Noise) Two refrigerant circuit 4 Scroll compressors (tandem) Plate evaporator (AISI 316) Microprocessor control Low operating water content in the plant Electronic expansion valve as standard “Polar” version for extreme conditions
Air Cooled Heat PumpAQVH 85-140
81-130 kW
Plate
Air cooled
Scroll
87-144 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater Double set point Electric heater inside buffer tank for additional heating Fan speed control Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Pressure switch Sequence phases control (standard) Sofstart Unit protection grilles Water filter Water flow switch (standard)
AQVH 85-140
Leaving water temperature(cooling mode)
Water °С from 5 to 18Water with glycol °С from -8 to 18
Air temperature(cooling mode)
BLN °С from 5 to 47ELN °С from -18 to 44
HT °С from -18 to 50 (85-115) from -18 to 47 (125-140)
Leaving water temperature (heating mode) °С from 20 to 55
Air temperature (heating mode)
°С from -10 to 20Polar Version °С from -15 to 20
External static pressureStandard fans P 0High pressure fans (HPF) P <120
Power supply V/ph/Hz 400/3~+N/50 (Nominal)
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
Air cooled Chiller & Heat Pump | 71
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
AQVH 85-140 BLN 85 95 105 115 125 140
Cooling
Cooling capacity1 kW 81,0 89,9 98,9 106,7 115,6 129,6Power input1 kW 27,5 31,5 34,2 36,8 41,6 46,6EER1 / Energy efficiency class 2,95/B 2,85/C 2,89/B 2,90/C 2,78/C 2,78/CESEER 3,78 3,81 3,86 3,96 3,69 3,77EER HSE1 / Energy efficiency class 3,05/B 2,94/B 2,97/B 2,96/B 2,84/C 2,84/CESEER HSE1 4,21 4,14 4,27 4,28 3,96 4,03SEER2 4,25 4,68 4,63 4,18 4,33 4,28
hsc2 167 184 182 164 170 168
SEER HSE2 4,6 5,03 4,95 4,55 4,6 4,5
hsc HSE2 181 198 195 179 181 177
Heating
Heating capacity3 kW 87,0 100,4 108,3 116,4 131,5 143,6Power input3 kW 25,7 31,1 32,9 35,7 42,0 45,7COP3 / Energy efficiency class 3,39/A 3,23/A 3,29/A 3,26/A 3,13/B 3,14/BCOP HSE3 / Energy efficiency class 3,54/A 3,47/A 3,52/A 3,47/A 3,36/A 3,36/ASCOP /Energy efficiency class4 3,61/ A+ 3,64/ A+ 3,78/ A+ 3,77/ A+ 3,47/ A+ 3,54/ A+
hsh4 141 143 148 148 136 139
Sound power level5 dB(A) 84 84 84 84 88 88Sound pressure level at 10 m6 dB(A) 52 52 52 52 56 56Sound power level HPF5 dB(A) 92 92 92 92 95 95Sound pressure level at 10 m HPF6 dB(A) 60 60 60 60 63 63
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.7 Input power (only compressors).
AQVH 85-140 ELN 85 95 105 115 125 140
Cooling
Cooling capacity1 kW 78,3 86,5 94,8 102,7 112,7 124,6Power input1 kW 28,7 33,3 36,2 39,4 43,5 47,6EER1 / Energy efficiency class 2,73/C 2,60/D 2,62/D 2,61/D 2,59/D 2,62/DESEER 3,57 3,57 3,61 3,52 3,50 3,59EER HSE1 / Energy efficiency class 2,84/C 2,70/C 2,71/C 2,69/D 2,65/D 2,67/DESEER HSE1 4,07 3,94 3,94 3,97 3,72 3,85SEER2 4,25 4,68 4,63 4,18 4,33 4,28
hsc2 167 184 182 164 170 168
SEER HSE2 4,6 5,03 4,95 4,55 4,6 4,5
hsc HSE2 181 198 195 179 181 177
Heating
Heating capacity3 kW 85,2 97,8 105,3 113,4 127,4 139,5Power input3 kW 25,3 30,6 32,5 35,4 40,1 44,0COP3 / Energy efficiency class 3,37/A 3,20/A 3,24/A 3,20/A 3,18/B 3,17/BCOP HSE3 / Energy Efficiency class 3,55/A 3,46/A 3,50/A 3,45/A 3,38/A 3,38/ASCOP /Energy efficiency class4 3,61/ A+ 3,64/ A+ 3,78/ A+ 3,77/ A+ 3,47/ A+ 3,54/ A+
hsh4 141 143 148 148 136 139
Sound power level5 dB(A) 82 82 82 82 86 86Sound pressure level at 10 m6 dB(A) 50 50 50 50 54 54
AQVH 85-140 HT 85 95 105 115 125 140
Cooling
Cooling capacity1 kW 83,6 93,4 103,8 111,7 118,0 132,1Power input7 kW 23,6 27,2 29,5 32,0 37,0 41,2EER 2,96 2,94 3,04 3,05 2,83 2,88ESEER 4,14 4,12 4,25 4,27 3,97 4,03SEER2 4,6 5,03 4,95 4,55 4,6 4,5
hsc2 181 198 195 179 181 177
Heating
Heating capacity5 kW 93,5 104,9 113,7 121,9 135,6 148,3Power input7 kW 24,5 28,1 30,1 32,8 37,2 40,9COP 3,22 3,21 3,28 3,26 3,25 3,26SCOP /Energy efficiency class4 3,99/ A++ 3,96/ A++ 4,12/ A++ 4,07/ A++ 3,73/ A+ 3,77/ A+
hsh4 157 155 162 160 146 148
Sound power level5 dB(A) 95 95 95 95 95 95Sound pressure level at 10 m6 dB(A) 63 63 63 63 63 63
| Air cooled Chiller & Heat Pump72
Physical features
Water Connections (Evaporator)Connection type Male gas threadedInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½”WeightOperating weight BLN - HT kg 1.090 1.105 1.149 1.180 1.227 1.301Operating weight ELN kg 1.120 1.135 1.179 1.210 1.257 1.331DimensionsLength mm 2.555 2.555 2.555 2.555 3.155 3.155Width mm 1.095 1.095 1.095 1.095 1.095 1.095Height mm 2.185 2.185 2.185 2.185 2.185 2.185
AQVH 85-140 85 95 105 115 125 140
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Air cooled Chiller & Heat Pump | 73
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Double Tree Hotel by HiltonDubai, United Arab Emirates
Site: HotelProduct: Air cooled chiller AQVL 95Application: Cold room application for kitchen
| Air cooled Chiller & Heat Pump74
Air Cooled Heat PumpSysAqua 140-210 H
Technical features 5 sizes Cooling capacity from 125,4 to 195,4 kW Heating capacity from 143,7 to 217,6 kW EER up to 2,88 SEER up to 3,91 SCOP up to 3,36
Product advantages SysCloud as standard Antifrost coil Extra low sound level Refrigerant R410A Blue fin coil in standard Extended operating limits High temperature operation up to 50°C Heating mode operation down to -17°C Leaving hot water up to 50°C High SEER and SCOP Low footprint Easy maintenance Leak detection according to BREEAM standard Low water pressure drop Two refrigerant circuits with tandem scroll compressors per
circuit for a higher efficiency at partial load Hydraulic circuit without pump in standard (including a not
mounted water filter) Finned coil waterproof treatment Modbus RTU and TCP/IP communication protocols as standard Return or leaving water temperature control Double water set point Night mode (extra low sound level) On/Of Remote Heat Cool mode remote Water flow switch (factory mounted) Phase monitor
125,4-195,4 kW
Plate
Air cooled
Scroll
143,7-217,6 kW
R410A
Main accessories and options
All seasons Antivibration mount rubber Antivibration spring Bacnet IP Finned coil Blygold treatment (upon request) Finned coil treatment epoxy High pressure fan Hydraulic circuit pack single or double pump Hydraulic gauges Nordic Pack Outdoor coil protection grid Refrigerant gauges HP/LP Remote control Shut off valves Sofstarter Variable pumps Water pressure switch Water tank 300L Without neutral
SysAqua 140-210 H
Leaving water temperature(Cooling mode)
Without glycol °С from 5 to 18With glycol 45% °С from -10 to 18
Air temperature (cooling mode) °С from -10 to 50Leaving water temperature (heating mode) °С from 20 to 50Air temperature (heating mode) °С from -17 to 20Power supply V/ph/Hz 400/3~+N/50 (Nominal)
Patented Antifrost coil !
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
NEW Variable pumps now available!
NEW
SysCloudThe operating parameters of your unit(s) at anytime, from anywhere!
Air cooled Chiller & Heat Pump | 75
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
SysAqua 140-210 H 140 150 170 190 210
Cooling
Cooling capacity1 kW 125,4 137,6 150,9 175,8 195,4Power input1 kW 43,6 47,8 52,7 64,8 72,5Total EER 100%1 2,88 2,88 2,86 2,71 2,69ESEER1 4,02 3,98 4,04 3,82 3,77Energy efficiency class (EER)1 B B B C CSEER3 3,87 3,87 3,91 3,69 3,68hsc
3 149 149 150 142 141
Heating
Heating capacity2 kW 143,7 153,7 170,1 194,9 217,6Power input2 kW 45,7 50,3 55,5 67,3 78,3SCOP4 3,32 3,36 3,31 3,29 3,23Energy efficiency class (SCOP)4 A+ A+ A+ A+ A+hsh
4 130 131 129 129 144Sound power level 5 dB(A) 85,4 85,4 87 88,1 88,1
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.3 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Following Eurovent standard.
Technical performance
Water Connections (Evaporator)Connection type VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 2”1/2WeightWithout water tank - 1 pump kg 1.685 1.705 1.798 1.891 2.201With water tank - 1 pump kg 2.139 2.159 2.253 2.343 2.653DimensionLength with tank mm 2.856 2.856 2.856 2.856 2.856Length without tank mm 3.666 3.666 3.666 3.666 3.666Width mm 2.210 2.210 2.210 2.210 2.210Height mm 2.295 2.295 2.321 2.321 2.321
Physical features
SysAqua 140-210 H 140 150 170 190 210
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump76
Technical feature 7 sizes Cooling capacity from 149,4 to 299,9 kW Heating capacity from 169,8 to 337,4 kW 3 versions:
STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions:
BLN (Base Low Noise) LN (Low Noise) ELN (Extra Low Noise) Two refrigerant circuits 4 Scroll compressors (tandem) Plate evaporator Microprocessor control Electronic expansion valve Inverter fans (Standard or HT) “Polar” version for extreme conditions (upon request)
Air Cooled Heat PumpVLH 604-1204
149-300 kW
Plate
Air cooled
Scroll
170-337 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets Desuperheater Fan speed control (-18°C) Hydrokit with 1 or 2 pumps with or without buffer tank (500 lt)
( +1mt of length) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
VLH 604-1204 604 704 804 904 1004 1104 1204
Leaving water temperature
Water °C from +6 to 15Water with glycol °C from 0 to 15Water with glycol (Brine version) °C from -8 to 15∆ T K from 3 to 8
Air temperature
BLN °C from -5to +47
from -5to +47
from 0to +46
from 0to +47
from 0to +46
from 0to +45
from 0to +45
Cooling LN °C from -5to +45
from -5to +45
from 0to +44
from 0to +45
from 0to +44
from 0to +42
from 0to +42
Cooling ELN °C from -18to +41
from -18to +41
from -18to +40
from -18 to +41
from -18 to +40
from -18to +38
from -18to +38
Cooling HT °C from -18to +49
from -18to +49
from -18to +48
from -18to +49
from -18to +48
from -18to +47
from -18to +47
Heating °C from -10 (-4 LN/ELN) to + 20
External static pressure
Standard fan P 0High pressure fans (HPF) P <120
Power supply V/ph/Hz 400/3/50 (Nominal)
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 77
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performance
VLH STD/HPF 604-1204 BLN 604 704 804 904 1004 1104 1204
Cooling
Cooling capacity1 kW 149,4 173,2 197,1 226,4 246,3 273,1 299,9Power input1 kW 56,4 66,1 72,2 82,6 86,7 99,7 114,0EER1 / Energy efficiency class 2,65/D 2,62/D 2,73/C 2,74/C 2,84/C 2,74/C 2,63/DESEER 3,38 3,41 3,43 3,45 3,57 3,46 3,41SEER2 3,6 3,63 3,55 3,35 3,5 3,53 3,43
hsc2 141 142 139 131 137 138 134
SEER HSE2 3,98 3,95 3,83 3,65 3,8 3,78 3,68
hsc HSE2 156 155 150 143 149 148 144
Heating
Heating capacity3 kW 169,8 200,1 223,2 254,7 270,8 302,1 337,4Power input3 kW 58,0 67,4 70,4 79,6 87,6 100,0 112,5COP3 / Energy efficiency class 2,93/B 2,97/B 3,17/B 3,20/A 3,09/B 3,02/B 3,00/BSCOP /Energy efficiency class 4 3,20/ A+ 3,41 / A+ 3,42 / A+ 3,28 / A+ 3,39 / A+ 3,30 / A+ 3,19 / A+
hsh4 125 133 134 128 133 129 125
Sound power level5 dB(A) 91 91 91 92 92 93 93Sound pressure level at 10 m6 dB(A) 59 59 59 60 60 61 61
VLH STD 604-1204 LN 604 704 804 904 1004 1104 1204
Cooling
Cooling capacity1 kW 145,4 168,2 191,2 220,4 237,3 261,2 285,1Power input1 kW 56,8 66,2 73,3 83,8 88,5 102,8 119,8EER1 / Energy efficiency class 2,56/D 2,54/D 2,61/D 2,63/D 2,68/D 2,54/D 2,38/EESEER 3,60 3,58 3,64 3,59 3,70 3,63 3,49SEER2 2,95 3 3 3,1 3,28 3,3 3,23
hsc2 115 117 117 121 128 129 126
SEER HSE2 3,98 3,95 3,83 3,65 3,80 3,78 3,68
hsc HSE2 156 155 150 143 149 148 144
Heating
Heating capacity3 kW 165,7 195,0 217,1 247,7 261,8 288,9 322,2Power input3 kW 56,0 65,2 68,3 76,9 84,7 97,0 109,2COP3 / Energy efficiency class 2,96/C 2,99/C 3,18/B 3,22/A 3,09/B 2,98/C 2,95/CSCOP /Energy efficiency class 4 3,20/ A+ 3,41 / A+ 3,42 / A+ 3,28 / A+ 3,39 / A+ 3,20 / A+ 3,19 / A+
hsh4 125 133 134 128 133 125 125
Sound power level5 dB(A) 87 87 87 88 88 89 89Sound pressure level at 10 m6 dB(A) 55 55 55 56 56 57 57
VLH STD 604-1204 ELN 604 704 804 904 1004 1104 1204
Cooling
Cooling capacity1 kW 141,5 164,3 185,2 214,5 230,4 253,3 276,1Power input1 kW 58,0 69,0 76,2 86,1 90,7 106,9 124,9EER1 / Energy efficiency class 2,44/E 2,38/E 2,43/E 2,49/E 2,54/D 2,37/E 2,21/FESEER 3,49 3,46 3,51 3,60 3,67 3,51 3,40SEER2 3,6 3,63 3,55 3,35 3,5 3,53 3,43
hsc2 141 142 139 131 137 138 134
SEER HSE2 3,98 3,95 3,83 3,65 3,8 3,78 3,68
hsc HSE2 156 155 150 143 149 148 144
Heating
Heating capacity3 kW 156,6 184,9 202,9 232,6 245,7 266,8 297,0Power input3 kW 55,0 64,9 67,0 75,8 83,9 95,0 108,0COP3/ Energy efficiency class 2,85/C 2,85/C 3,03/B 3,07/B 2,93/B 2,81/C 2,75/CCOP HSE3 2,95 2,95 3,13 3,19 3,04 2,90 2,83SCOP /Energy efficiency class 4 3,20/ A+ 3,41 / A+ 3,42 / A+ 3,28 / A+ 3,39 / A+ 3,30 / A+ 3,19 / A+
hsh4 125 133 134 128 133 129 125
Sound power level5 dB(A) 83 83 83 84 84 85 85Sound pressure level at 10 m6 dB(A) 51 51 51 52 52 53 53
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Air cooled Chiller & Heat Pump78
Physical feature
EvaporatorConnection type Male gas threadedInlet/outlet diameter inch 2½” 2½” 2½” 3” 3” 3” 3”WeightOperating weight BLN -LN kg 1.485 1.675 1.820 1.980 2.125 2.215 2.225Operating weight ELN kg 1.520 1.710 1.855 2.015 2.165 2.255 2.265Operating weight HT kg 1.515 1.705 1.850 2.020 2.165 2.255 2.265DimensionsLength mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300
VLH STD/HPF 604-1204 604 704 804 904 1004 1104 1204
VLH 604-1204 HT 604 704 804 904 1004 1104 1204
Cooling
Cooling capacity1 kW 151,7 175,6 199,7 229,5 250,1 276,5 305,6Power input4 kW 49,2 58,4 64,4 73,2 76,8 89,9 102,8EER / Energy efficiency class 2,69/D 2,69/D 2,80/D 2,77/D 2,88/D 2,77/D 2,71/ESEER2 2,95 3 3 3,1 3,28 3,3 3,23
hsc2 115 117 117 121 128 129 126
Heating
Heating capacity3 kW 170,5 200,7 224,0 256,6 273,7 305,5 341,5Power input4 kW 51,3 60,6 63,5 71,4 79,3 91,4 103,5COP / Energy efficiency class 2,91/C 2,97/C 3,18/B 3,17/A 3,07/B 3,01/C 3,01/CSCOP /Energy efficiency class 5 3,43/ A+ 3,44 / A+ 3,40 / A+ 3,32 / A+ 3,33 / A+ 3,37 / A+ 3,26 / A+
hsh5 134 135 133 130 130 132 127
Sound power level6 dB(A) 99 99 99 100 100 100 100Sound pressure level at 10 m7 dB(A) 67 67 67 68 68 68 68
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.4 Input power (only compressors).5 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.6 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.7 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Air cooled Chiller & Heat Pump | 79
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Expo 2015Milan, Italy
Site: China pavilionProduct: Water cooled chiller WQH 75Application: Air conditioning
| Air cooled Chiller & Heat Pump80
Air Cooled Heat PumpSyScroll 140-360 Air EVO HP
Technical features 9 sizes Cooling capacity from 136,7 to 340,5 kW Heating capacity from 144,9 to 361,4 kW 4 versions:
STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
“Polar” version: Heat Pump for extreme conditions
Two refrigerant circuits 4 Scroll compressors (tandem) Plate evaporator Electronic expansion valve
* For Liquid outlet temperature <0 °C provide Brine Version (upon request for HP).1 Voltage 400V +/- 10%.
137-340 kW
Plate
Air cooled
Scroll
145-361 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater Fan speed control (standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank (350lt
140-170, 500lt 200-360) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
SyScroll 140-360 Air EVO HP
Chilled liquid Liquid outlettemperature
Water °С from 5 to 18Water with glycol* °С from -10 to 5ΔT K from 3 to 7
Ambient air Air enteringtemp. Cooling
- / L / S °С 5 to 48 / 0 to 46 / 14 to 44EC-HT °С from -18 to 50
Warm Liquid Liquid outlettemperature
Water °С from +20 to 55ΔT K from 3 to 7
Ambient air Air enteringtemp. Heating
- / L / S / EC °С from -10 to 20Polar Version °С from -13 to 20HT °С from -13 to 20
External static pressureStandard fans P 0High pressure fans (HPF) P <120
Power supply 1 V/ph/Hz 400 /3/50 (Nominal)
ErP20182017
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Air cooled Chiller & Heat Pump | 81
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performanceSyScroll 140-360 Air EVO HP 140 170 200 230 260 280 300 330 360
Cooling
Nominal cooling capacity1 kW 136,7 154,5 181,3 213,6 243,7 261,1 287,8 307,4 340,5Input power1 kW 45,1 54,6 61,9 73,2 83,8 90,7 98,5 103,5 117,0EER1/Energy efficiency class 3,03/B 2,83/C 2,93/B 2,92/B 2,91/B 2,88/C 2,92/B 2,97/B 2,91/BEER* / EER** 3,08/2,86 2,86/2,69 2,97/2,73 2,96/2,75 2,95/2,73 2,91/2,71 2,96/2,75 3,02/2,78 2,95/2,74ESEER 3,52 3,47 3,60 3,71 3,71 3,65 3,60 3,64 3,65ESEER* /ESEER** 3,62/3,38 3,57/3,50 3,71/3,46 3,83/3,56 3,83/3,6 3,78/3,51 3,71/3,46 3,71/3,57 3,76/3,51SEER2 3,8 3,95 4,22 4,13 4,05 4,1 3,83 3,8 3,93hsc
2 149 155 166 162 159 161 150 149 154SEER* / SEER**2 3,95 4,08 4,35 4,22 4,13 4,2 3,93 3,8 4,05hsc
* / hsc**2 155 160 171 166 162 165 154 149 159
Heating
Nominal heating capacity3 kW 144,9 165,7 200,1 229,0 262,3 279,6 305,6 327,2 361,4Input power3 kW 44,9 51,6 62,1 70,9 81,7 87,4 94,9 101,9 112,6COP3/ Energy efficiency class 3,23/A 3,21/A 3,22/A 3,23/A 3,21/A 3,20/A 3,22/A 3,21/A 3,21/ACOP* 3,28 3,25 3,28 3,27 3,26 3,25 3,27 3,26 3,26COP** 3,05 3,05 3,01 3,03 3,01 3,02 3,02 2,99 3,02Nominal heating capacity4 kW 148,6 170,0 207,0 233,8 268,4 285,6 311,0 333,9 367,9Input power4 kW 37,2 43,6 52,7 58,7 67,8 72,3 77,8 83,7 92,7COP4 4,00 3,90 3,93 3,98 3,96 3,95 4,00 3,99 3,97SCOP /Energy efficiency class / hsh
53,39/A+/
1333,42/A+/
1343,34/A+/
1313,46/A+/
1353,48/A+/
1363,44/A+/
1353,51/A+/
1373,44/A+/
1353,48/A+/
136Sound power level6 dB(A) 90 90 92 92 93 93 94 95 95Sound pressure level at 10 m7 dB(A) 47 47 50 50 51 51 53 54 54
SyScroll 140-360 Air EVO HP L 140 170 200 230 260 280 300 330 360
Cooling
Nominal cooling capacity1 kW 132,9 149,3 176,9 207,2 236,9 253,3 279,4 299,1 330,1Input power1 kW 45,2 55,3 61,2 73,7 83,7 91,4 99,1 103,1 117,5EER1 / Energy efficiency class 2,94/B 2,70/C 2,89/C 2,81/C 2,83/C 2,77/C 2,82/C 2,90/C 2,81/CESEER 3,59 3,55 3,67 3,78 3,76 3,72 3,67 3,67 3,72EER*/ Energy efficiency class* 2,98/B 2,73/C 2,93/B 2,85/C 2,87/C 2,81/C 2,86/C 2,94/B 2,84/CESEER* 3,69 3,66 3,78 3,91 3,89 3,85 3,78 3,75 3,83SEER2 3,8 3,95 4,22 4,13 4,05 4,1 3,83 3,8 3,93hsc
2 149 155 166 162 159 161 150 149 154SEER*2 4,58 4,65 3,75 3,7 3,65 3,63 2,58 2,65 4,17hsc
*2 180 183 147 145 143 142 100 103 164
Heating
Nominal heating capacity3 kW 141,0 162,1 193,7 223,7 255,6 272,3 299,4 320,8 353,9Input power3 kW 43,5 50,3 60,0 69,0 79,4 84,8 92,7 99,6 109,9COP3 / Energy efficiency class 3,24/A 3,22/A 3,23/A 3,24/A 3,22/A 3,21/A 3,23/A 3,22/A 3,22/ANominal heating capacity4 kW 144,2 165,8 199,8 227,8 260,8 277,3 303,8 326,4 359,2Input power4 kW 35,8 42,2 50,5 56,5 65,2 69,8 75,2 81,0 89,8COP4 4,03 3,93 3,96 4,03 4,00 3,97 4,04 4,03 4,00COP* 3,32 3,30 3,32 3,32 3,31 3,29 3,31 3,31 3,30SCOP /Energy efficiency class / hsh
53,39/A+/
1333,42/A+/
1343,34/A+/
1313,46/A+/
1353,48/A+/
1363,44/A+/
1353,51/A+/
1373,44/A+/
1353,48/A+/
136Sound power level6 dB(A) 85 85 87 87 88 88 89 90 90Sound pressure level at 10 m7 dB(A) 58 58 60 60 61 61 62 63 63
SyScroll 140-360 Air EVO HP S 140 170 200 230 260 280 300 330 360
Cooling
Nominal cooling capacity1 kW 125,9 140,3 168,5 194,7 224,0 238,5 263,3 283,5 310,5Input power1 kW 47,2 57,7 63,4 77,6 88,2 96,6 104,5 108,2 124,2EER1/ Energy efficiency class 2,67/D 2,43/D 2,66/D 2,51/D 2,54/D 2,47/D 2,52/D 2,62/D 2,50/DESEER 3,66 3,64 3,75 3,85 3,82 3,80 3,75 3,71 3,80EER*/Energy efficiency class* 2,71/C 2,45/D 2,70/C 2,54/D 2,58/D 2,50/D 2,55/D 2,66/D 2,53/DESEER* 3,77 3,75 3,86 3,99 3,95 3,93 3,86 3,79 3,91SEER2 3,8 3,95 4,22 4,13 4,05 3,60 3,83 3,8 3,93hsc
2 149 155 166 162 159 141 150 149 154SEER*2 4,58 4,65 3,75 3,7 3,65 3,63 2,58 2,65 4,17hsc
*2 180 183 147 145 143 142 100 103 164
Heating
Nominal heating capacity3 kW 138,5 159,5 189,8 219,8 250,8 267,1 294,7 315,0 348,9Input power3 kW 42,4 48,9 58,0 67,2 77,2 82,4 90,4 96,9 107,4COP3/ Energy efficiency class 3,27/A 3,26/A 3,27/A 3,27/A 3,25/A 3,24/A 3,26/A 3,25/A 3,25/ANominal heating capacity4 kW 141,3 162,7 195,3 223,3 255,3 271,3 298,3 319,7 353,2Input power4 kW 34,9 41,1 49,1 55,1 63,5 67,8 73,5 78,9 87,6COP4 4,05 3,96 3,98 4,05 4,02 4,00 4,06 4,05 4,03SCOP /Energy efficiency class / hsh
53,39/A+/
1333,42/A+/
1343,34/A+/
1313,46/A+/
1353,48/A+/
1363,44/A+/
1353,51/A+/
1373,44/A+/
1353,48/A+/
136Sound power level6 dB(A) 79 79 82 82 83 83 85 86 86Sound pressure level at 10 m7 dB(A) 53 53 55 55 56 56 57 58 58
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard. 4 Data refers to 35°C leaving warm water temperature and 7°C condenser air temperature with 87% R.H., according EN14511 standard.5 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.6 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 7 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.* High Efficiency Units (EC) with inverter fans.** HPF Units with high static pressure fans.
| Air cooled Chiller & Heat Pump82
Water Connections (Evaporator)Type Male gas threadedInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 3” 3” 3” 3” 3” 3”WeightOperating weight - / L kg 1.312 1.355 1.858 1.993 2.216 2.226 2.806 2.899 2.909Operating weight S kg 1.317 1.360 1.863 1.998 2.221 2.231 2.811 2.904 2.914Operating weight HT kg 1.342 1.385 1.908 2.043 2.276 2.286 2.876 2.979 2.989DimensionsLength mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard. 4 Input power (only compressors).5 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.6 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 7 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Physical features
SyScroll 140-360 Air EVO HP HT 140 170 200 230 260 280 300 330 360
Cooling
Nominal cooling capacity1 kW 137,9 156,0 182,5 215,5 245,8 263,4 290,3 309,8 343,4Input power4 kW 39,0 48,4 52,3 63,2 71,9 78,6 84,9 88,0 101,0EER/ Energy efficiency class 2,92/B 2,75/C 2,77/C 2,80/C 2,78/C 2,77/C 2,80/C 2,82/C 2,79/CESEER 3,45 3,38 3,53 3,63 3,65 3,58 3,53 3,60 3,58SEER2 3,68 3,78 4,5 3,8 3,73 3,78 4,28 3,95 4,08hsc
2 144 148 177 149 146 148 168 155 160
Heating
Nominal heating capacity3 kW 147,0 168,5 202,8 232,3 266,0 283,7 309,8 331,5 366,5Input power4 kW 39,2 46,0 52,8 61,8 70,7 76,1 82,3 87,1 97,8COP/ Energy efficiency class 3,11/B 3,12/B 3,07/B 3,10/B 3,07/B 3,08/B 3,08/B 3,06/B 3,08/BSCOP /Energy efficiency class / hsh
53,55/A+/
1393,58/A+/
1403,44/A+/
1353,56/A+/
1393,57/A+/
1403,53/A+/
1383,61/A+/
1413,55/A+/
1393,58/A+/
140Sound power level6 dB(A) 92 92 94 94 96 96 97 98 98Sound pressure level at 10 m7 dB(A) 60 60 62 62 64 64 65 66 66
SyScroll 140-360 Air EVO HP 140 170 200 230 260 280 300 330 360
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Air cooled Chiller & Heat Pump | 83
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Holiday InnUfa, Russia
Site: HotelProduct: Air Cooled Chillers, SyScroll 660 Air and 260 Air EVOApplication: Air conditioning
| Air cooled Chiller & Heat Pump84
Air Cooled Heat PumpSyScroll 400-900 Air EVO HP
Technical features 11 sizes Cooling capacity from 374 to 839 kW Heating capacity from 404 to 902 kW 3 versions:
STD (Standard) EC (Invert fans) HPF (High Pressure Fans) 2 acoustic versions:
- (Standard) S (Super Low Noise) "Polar” version: Heat Pump for extreme conditions Two refrigerant circuits 4 / 5 / 6 / 8 Scroll compressors Plate Evaporator Electronic expansion valve
1 Voltage 400V +/- 10%.
374-839 kW
Plate
Air
Scroll
404-902 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater and total heat recovery (TR version) Fan speed control (standard a Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank (500 lt
400-450, 1000 lt 470-670) Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
SyScroll 400-900 Air EVO HP
Chilled liquid Liquid outlettemperature
Water °С from 5 to 18Water with glycol °С from -3 to 5ΔT K from 3 to 7
Ambient air Air enteringtemp. Cooling
_ / EC °С from 10 to 46S / EC S °С from -18 to 46
Warm Liquid Liquid outlettemperature
Water °С from 25 to 55ΔT K from 3 to 7
Ambient air Air enteringtemp. Heating
_ °С from -10 to 20S / EC / EC S °С from -10 to 35PH °С from -13 to 35
External static pressureStandard fans P 0High pressure fans (HPF) P <120
Power supply 1 V/ph/Hz 400 /3/50 (Nominal)
ErP20182017
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
Air cooled Chiller & Heat Pump | 85
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performanceSyScroll 400-900 Air EVO HP 400 450 490 530 580 620 670 750 800 850 900
Cooling
Nominal cooling capacity1 kW 373,5 419,2 454,5 489,7 535,7 581,5 625,4 701,4 748,1 795,2 838,7Input power1 kW 132,3 147,8 160,9 173,0 190,2 206,1 221,5 247,4 263,8 280,5 295,4EER1/ Energy efficiency class 2,82/C 2,84/C 2,82/C 2,83/C 2,82/C 2,82/C 2,82/C 2,84/C 2,84/C 2,83/C 2,84/CESEER 3,81 3,65 3,76 3,81 3,82 3,75 3,66 3,71 3,72 3,65 3,58EER1 */ Energy efficiency class 2,90/B 2,91/B 2,90/B 2,90/B 2,90/B 2,90/B 2,90/B 2,91/B 2,91/B 2,91/B 2,91/BESEER* 3,96 3,79 3,91 4,00 4,01 3,94 3,84 3,83 3,87 3,80 3,72SEER2 4,65 4,53 4,7 4,55 4,33 4,35 4,3 4,3 4,35 4,3 4,3
hsc2 183 178 185 179 170 171 169 169 171 169 169
SEER*2 4,93 4,83 4,97 4,88 4,5 4,5 4,45 4,45 4,47 4,47 4,47
hsc*2 194 190 196 192 177 177 175 175 176 176 176
Heating
Nominal heating capacity3 kW 404,0 450,9 492,7 532,1 585,8 627,7 677,8 758,3 807,3 856,9 901,6Input power3 kW 125,9 140,8 153,8 166,3 183,0 195,5 212,0 237,0 252,3 267,2 281,3COP3 3,21/A 3,20/A 3,20/A 3,20/A 3,20/A 3,21/A 3,20/A 3,20/A 3,20/A 3,21/A 3,21/ASCOP4/Energy efficiency class 3,46/A+ 3,47/A+ 3,37/A+ 3,38/A+ / / / / / / /
hsh4 135 136 132 132 / / / / / / /
COP3 */Energy efficiency class 3,30/A 3,29/A 3,29/A 3,29/A 3,29/A 3,31/A 3,29/A 3,29/A 3,29/A 3,29/A 3,29/ASCOP4 */Energy efficiency class 3,62/A+ 3,62/A+ 3,53/A+ 3,53/A+ / / / / / / /
hsh4 * 142 142 138 138 / / / / / / /
Sound power level5 dB(A) 92 93 93 94 94 95 95 95 95 96 96Sound pressure level at 10 m6 dB(A) 60 61 60 61 61 62 62 62 62 63 63
1 Cooling operation. Water / Plant side heat exchanger: RWT = 12 [°C] / LWT = 7 [°C]. Air / Source side heat exchanger: OAT = 35 [°C]. Declared data are in accordance with EN14511 / 2013.
2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Heating operation. Water / Plant side heat exchanger: RWT = 40 [°C] / LWT = 45 [°C]. Air / Source side heat exchanger: OAT DB / WB = 7 / 6 [°C]. Declared data are in
accordance with EN14511 / 2013.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound power level is declared in nominal full load condition (cooling operation), referring to ISO standard 9614, in accordance with Eurovent certification program.6 Sound pressure level refer to ISO Standard 3744, parallelepiped shape in a free field on a reflective surface.* EC version: brushless fan motors version.
SyScroll 400-900 Air EVO HP S 400 450 490 530 580 620 670 750 800 - -
Cooling
Nominal cooling capacity1 kW 371,2 417,3 453,4 487,3 531,4 578,6 621,5 701,5 743,2 - -Input power1 kW 128,1 143,6 156,5 167,6 183,3 199,0 214,1 241,4 256,6 - -EER1/Energy efficiency class 2,90/B 2,91/B 2,90/B 2,91/B 2,90/B 2,91/B 2,90/B 2,91/B 2,90/B - -ESEER 4,02 3,85 3,97 4,02 4,03 3,96 3,86 3,91 3,92 - -EER1 */ Energy efficiency class 2,98/B 2,99/B 2,98/B 2,99/B 2,98/B 2,99/B 2,99/B 2,99/B 2,98/B - -ESEER* 4,16 3,97 4,11 4,22 4,24 4,18 4,05 4,07 4,08 - -SEER 2 5,03 4,53 5,1 5,05 4,6 4,6 4,55 4,55 4,58 - -
hsc 2 198 178 201 199 181 181 179 179 180 - -
SEER* 2 5,35 5,33 5,45 5,48 4,75 4,72 4,7 4,65 4,65 - -
hsc* 2 211 210 215 216 187 186 185 183 183 - -
Heating
Nominal heating capacity3 kW 403,6 451,7 490,3 531,2 585,6 627,1 676,7 757,4 805,3 - -Input power3 kW 124,3 138,2 152,2 165,9 182,9 193,2 209,6 234,0 247,7 - -COP3/ Energy efficiency class 3,25/A 3,27/A 3,22/A 3,20/A 3,20/A 3,25/A 3,23/A 3,24/A 3,25/A - -SCOP4/ Energy efficiency class 3,76/A+ 3,76/A+ 3,69/A+ 3,68/A+ / / / / / - -
hsh4 147 147 145 144 / / / / / - -
COP3 * / Energy efficiency class 3,34/A 3,37/A 3,32/A 3,29/A 3,30/A 3,34/A 3,32/A 3,34/A 3,35/A - -SCOP4 * 3,99 3,98 3,91 3,89 / / / / / - -Energy efficiency class A++ A++ A++ A++ / / / / / - -
hsh4 * 157 156 153 153 / / / / / - -
Sound power level5 dB(A) 86 87 87 87 88 88 88 89 89 - -Sound pressure level at 10 m6 dB(A) 53 54 54 54 55 55 55 56 56 - -
Physical featuresSyScroll 400-900 Air EVO HP 400 450 490 530 580 620 670 750 800 850 900
Water Connections (Evaporator)Type VictaulicInlet/outlet diameter inch 4" 5" 6" WeightOperating weight _ / EC / HPF Kg 3.769 3.938 4.412 4.744 5.214 5.554 5.691 6.790 6.985 7.231 7.408Operating weight S / EC S Kg 4.131 4.293 4.764 5.101 5.567 5.919 6.059 7.497 7.683 - -Dimensions HPLength _ / EC / HPF mm 5.620 5.620 6.680 6.680 7.760 8.800 8.800 9.950 9.950 11.000 11.000Length S / EC S mm 6.680 6.680 7.760 7.760 8.800 9.850 9.850 12.050 12.050 - -Width mm 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175 2.175Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
| Air cooled Chiller & Heat Pump86
Air Cooled Heat PumpSyScroll 240-660 Air HP
Technical features 10 sizes Cooling capacity from 216,5 to 580,6 kW Heating capacity from 255,9 to 679,1 kW 3 versions:
STD (Standard) HT (High Temperature) HPF (High Pressure Fans) 3 acoustic versions:
- (Basic Low Noise) L (Low Noise) S (Super Low Noise) Two refrigerant circuits 3/4/5/6 Scroll compressors Plate evaporator Electronic expansion valve
* For Liquid outlet temperature <0 °C provide Brine Version (available for CO; upon request for HP).1 Voltage 400V +/- 10%.
217-581 kW
Plate
Air cooled
Scroll
256-679 kW
R410A
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard as Super Low Noise) Desuperheater Fan speed control (standard as Super Low Noise version) Hydrokit with 1 or 2 pumps with or without buffer tank Mechanical gauges Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstarter Unit protection grilles Water differential pressure switch (standard) Water filter Water flow switch
SyScroll 240-660 Air HP
Chilled liquid Liquid outlettemperature
Water °С from 6 to 18Water with glycol* °С from -10 to 6ΔT K from 3 to 7
Ambient air
Air enteringtemp. Cooling
- °С from 5 to 42L °С from 5 to 40S °С from -14 to 40HT-HPF °С from -18 to 44
External static pressureStandard fans P 0High pressure fans (HPF) P <120
Warmed liquid Liquid outlettemperature
Water °С from 20 to 52ΔT K from 3 to 7
Ambient air Air enteringtemperature heating
- / L / S °С from -10 to 20HT °С from -12 to 20
Power supply 1 V/ph/Hz 400 /3/50 (Nominal)
ErP20182017
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
Air cooled Chiller & Heat Pump | 87
AIR
COOL
ED C
HILL
ER &
HE
AT P
UMP
Technical performanceSyScroll 240-660 Air HP (STD-EC-HPF) 240 270 290 320 360 420 470 540 590 660
Cooling
Nominal cooling capacity1 kW 216,5 251,6 263,8 287,1 330,0 380,7 435,1 481,9 530,7 580,6Input power1 kW 85,5 100,5 105,2 113,9 131,3 151,7 169,1 189,9 207,3 228,3EER1/ Energy efficiency class 2,53/D 2,50/D 2,51/D 2,52/D 2,51/D 2,51/D 2,57/D 2,54/D 2,56/D 2,54/DESEER 3,55 3,43 3,52 3,66 3,66 3,79 3,80 3,66 3,74 3,82EER*/EER** 2,56/2,41 2,53/2,4 2,54/2,38 2,55/2,41 2,54/2,4 2,54/2,4 2,60/2,46 2,56/2,42 2,59/2,44 2,57/2,43ESEER*/ESEER** 3,63/3,21 3,50/3,16 3,60/3,19 3,74/3,32 3,74/3,31 3,88/3,43 3,89/3,45 3,74/3,35 3,81/3,41 3,90/3,58SEER3 4,25 4,25 4,1 3,83 4,18 3,85 3,85 4,22 4,3 4,25
hsc3 167 167 161 150 164 151 151 166 169 167
SEER*3 3,9 3,9 4,28 3,88 4,2 4,35 4,2 4,3 4,43 4,33
hsc*3 153 153 168 152 165 171 165 169 174 170
Heating
Nominal heating capacity2 kW 255,9 289,1 313,3 333,0 382,4 444,0 491,5 556,4 605,0 679,1Input power2 kW 92,7 106,8 117 117,4 136,2 159,7 170,5 191,2 209,2 231,1COP2/ Energy efficiency class 2,76/D 2,71/D 2,68/D 2,84/C 2,81/C 2,78/D 2,88/C 2,91/C 2,89/C 2,94/CCOP* 2,79 2,73 2,71 2,87 2,84 2,81 2,91 2,94 2,92 2,97COP** 2,63 2,60 2,56 2,71 2,68 2,66 2,75 2,78 2,76 2,81SCOP /Energy efficiency class4 3,39/A+ 3,50/A+ 3,38/A+ 3,59/A+ 3,51/A+ 3,64/A+ 3,42/A+ - - -
hsh4 133 137 132 141 137 143 134 - - -
Sound power level5 dB(A) 93 93 94 94 94 95 95 96 96 97Sound pressure level at 10 m6 dB(A) 61 61 62 62 62 63 63 64 63 64
SyScroll 240-660 Air HP L 240 270 290 320 360 420 470 540 590 660
Cooling
Nominal cooling capacity1 kW 204,9 236,3 249,9 269,8 311,1 358,4 409,7 453,2 499,5 545,9Input power1 kW 88,6 105,2 109,0 118,7 137,0 158,0 176,3 197,8 216,1 237,8EER1/ Energy efficiency class 2,31/E 2,24/F 2,29/F 2,27/F 2,27/F 2,27/F 2,32/E 2,29/F 2,31/E 2,30/FESEER 3,50 3,29 3,51 3,56 3,66 3,80 3,77 3,60 3,82 3,79SEER3 3,85 3,85 4,18 3,83 4,1 4,25 4,25 4,28 4,3 4,3
hsc3 151 151 164 150 161 167 167 168 169 169
Heating
Nominal heating capacity2 kW 253,0 285,5 309,7 328,9 377,7 438,6 485,4 539,8 597,5 670,7Input power2 kW 90,1 104,1 113,6 114,1 132,3 155,1 165,7 188 202,7 224COP2/ Energy efficiency class 2,81/C 2,74/D 2,72/D 2,88/C 2,86/C 2,83/C 2,93/C 2,87/C 2,95/C 2,99/CSCOP /Energy efficiency class4 3,39/A+ 3,50/A+ 3,38/A+ 3,65/A+ 3,51/A+ 3,64/A+ 3,49/A+ - - -
hsh4 133 137 132 143 137 143 137 - - -
Sound power level5 dB(A) 88 88 89 89 90 91 91 91 92 92Sound pressure level at 10 m6 dB(A) 56 56 57 57 58 59 59 59 59 59
SyScroll 240-660 Air HP S 240 270 290 320 360 420 470 540 590 660
Cooling
Nominal cooling capacity1 kW 186,8 212,3 228,4 243,4 281,5 324,0 370,5 409,0 451,5 492,5Input power1 kW 96,3 115,5 117,9 129,4 149,7 172,0 192,4 215,4 235,6 258,9EER1/ Energy efficiency class 1,94/G 1,84/G 1,94/G 1,88/G 1,88/G 1,88/G 1,93/G 1,90/G 1,92/G 1,90/GESEER 3,28 3,12 3,30 3,38 3,62 3,60 3,61 3,70 3,76 3,64SEER3 3,85 3,85 4,18 3,83 4,1 4,25 4,25 4,28 4,3 4,3
hsc3 151 151 164 150 161 167 167 168 169 169
Heating
Nominal heating capacity2 kW 249,0 280,7 304,8 323,3 371,4 431,3 477,3 540,4 587,5 659,5Input power2 kW 87,5 101 110 111,1 128,8 150,6 161,4 179,9 197,4 219,8COP2/ Energy efficiency class 2,85/C 2,78/D 2,77/D 2,91/C 2,88/C 2,86/C 2,96/C 3,00/B 2,98/C 3,00/BSCOP /Energy efficiency class 4 3,39/A+ 3,50/A+ 3,38/A+ 3,65/A+ 3,51/A+ 3,64/A+ 3,49/A+ - - -
hsh4 133 137 132 143 137 143 137 - - -
Sound power level5 dB(A) 85 86 87 87 88 88 89 89 90 90Sound pressure level at 10 m6 dB(A) 53 54 55 55 56 56 57 57 57 57
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Data refers to 45°C leaving warm water temperature and 7°C ambient coil air temperature with 87% R.H., according EN14511 standard.3 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.4 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.5 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.6 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.* Unità alta temperatura (HT) con ventilatori inverter.** HPF Units with high static pressure fans.
Water Connections (Evaporator)Type Male gas threaded VictaulicInlet/outlet diameter inch 3” 3” 3” 3” 4” 4” 4” 4” 5” 5”WeightOperating weight kg 1.948 1.949 2.055 2.122 2.534 2.659 3.189 3.316 3.762 3.873DimensionsLength mm 3.500 3.500 3.500 3.500 4.550 4.550 5.600 5.600 6.650 6.650Width mm 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150 2.150Height mm 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500 2.500
SyScroll 240-660 Air HP 240 270 290 320 360 420 470 540 590 660
Physical features
| Air cooled Chiller & Heat Pump88
RestaurantFlorence, Italy
Site: RestaurantProduct: Air cooled chiller SysScroll 85 AirApplication: Air conditioning
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
89
Water Cooled Chiller,Heat Pump and Condensing unit
WQL/WQH/WQRC 20-190 21-193 kW 24-212 kW R410A Scroll PlatePage 94
WQL/WQH/WQRC 524-1604 154-478 kW 170-419 kW R410A Scroll PlatePage 98
SyScrew 440-1550 Water EVO CO/HP/RC 444-1.567 kW R134a Screw Shell & TubePage 102
ErP2018
ErP20182017
ErP2018
ErP20182017
ErP2018
| Water cooled Chiller & Heat Pump90
Selection guide Water Cooled Chiller
Product Range Cooling Capacity EER Flow rate Acoustic Power
Size (LxHxW) mm
WQL
20-
190
WQL 20 21,2 kW 4,58 1,02 l/s 65 dB(A) 821 x
1.350 x 455
WQL 25 26,2 kW 4,54 1,26 l/s 67 dB(A) 821 x
1.350 x 455
WQL 30 31,1 kW 4,46 1,5 l/s 67 dB(A) 821 x
1.350 x 455
WQL 35 34,8 kW 4,53 1,68 l/s 68 dB(A) 821 x
1.350 x 455
WQL 40 39,2 kW 4,48 1,89 l/s 68 dB(A) 821 x
1.350 x 455
WQL 45 46,6 kW 4,57 2,24 l/s 70 dB(A) 821 x
1.350 x 455
WQL 50 50,9 kW 4,29 2,44 l/s 70 dB(A) 1.210 x
1.500 x 850
WQL 60 61,1 kW 4,48 2,93 l/s 70 dB(A) 1.210 x
1.500 x 850
WQL 75 77,3 kW 4,48 3,71 l/s 72 dB(A) 1.210 x
1.500 x 850
WQL 90 91,1 kW 4,38 4,37 l/s 73 dB(A) 1.210 x
1.500 x 850
WQL 120 118,4 kW 4,46 5,68 l/s 78 dB(A) 1.210 x
1.500 x 850
WQL 150 147,1 kW 4,46 7,05 l/s 81 dB(A) 1.210 x
1.500 x 850
WQL 170 170 kW 4,50 8,15 l/s 81 dB(A) 1.210 x
1.500 x 850
WQL 190 192,7 kW 4,51 9,24 l/s 81 dB(A) 1.210 x
1.500 x 850
WQL
524
-160
4
WQL 524 154,3 kW 4,51 7,4 l/s 81 dB(A) 2.250 x
1.845 x 850
WQL 604 181,8 kW 4,37 8,71 l/s 82 dB(A) 2.250 x
1.845 x 850
WQL 704 208,9 kW 4,40 10,01 l/s 85 dB(A) 2.250 x
1.845 x 850
WQL 804 232,6 kW 4,36 11,2 l/s 87 dB(A) 2.250 x
1.845 x 850
WQL 904 265,8 kW 4,48 12,7 l/s 89 dB(A) 2.250 x
1.845 x 850
WQL 1004 295,6 kW 4,51 14,1 l/s 90 dB(A) 2.250 x
1.845 x 850
WQL 1104 338 kW 4,51 16,2 l/s 90 dB(A) 2.250 x
1.845 x 850
WQL 1204 379,2 kW 4,55 18,2 l/s 90 dB(A) 2.250 x
1.845 x 850
WQL 1404 429,1 kW 4,51 20,5 l/s 90 dB(A) 2.250 x
1.845 x 850
WQL 1604 478,4 kW 4,45 22,9 l/s 90 dB(A) 2.250 x
1.845 x 850
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
91
Product Range Capacity EER Flow rate Acoustic Power
Size (LxHxW) mm
SySc
rew
440
-155
0Wat
er E
VO C
O
SyScrew 440 Water EVO CO
444,3 kW 5,06 21,3 l/s 95 dB(A) 3.620 x 1.750 x 1.350
SyScrew 490 Water EVO CO
494,4 kW 5,05 23,6 l/s 95 dB(A) 3.620 x 1.750 x 1.350
SyScrew 570 Water EVO CO
570,4 kW 5,07 27,3 l/s 95 dB(A) 4.210 x 1.750 x 1.350
SyScrew 630 Water EVO CO
636,2 kW 5,07 30,5 l/s 95 dB(A) 4.210 x 1.750 x 1.350
SyScrew 700 Water EVO CO
708,5 kW 5,05 33,9 l/s 95 dB(A) 4.180 x 1.750 x 1.350
SyScrew 770 Water EVO CO
787,1 kW 5,06 37,7 l/s 95 dB(A) 4.180 x 1.750 x 1.350
SyScrew 860 Water EVO CO
875,5 kW 5,06 41,94 l/s 98 dB(A) 4.400 x 1.710 x 1.520
SyScrew 920 Water EVO CO
936 kW 5,05 44,86 l/s 98 dB(A) 4.400 x 1.710 x 1.520
SyScrew 990 Water EVO CO
998,6 kW 5,05 47,86 l/s 98 dB(A) 4.600 x 1.710 x 1.520
SyScrew 1070 Water EVO CO
1.071,4 kW 5,06 51,36 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1130 Water EVO CO
1.132,9 kW 5,06 54,33 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1220 Water EVO CO
1.224,1 kW 5,08 58,61 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1280 Water EVO CO
1.285,2 kW 5,06 61,56 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1400 Water EVO CO 1.428,5 kW 5,06 68,53 l/s 98 dB(A) 5.350 x
1.710 x 1.520
SyScrew 1550 Water EVO CO
5,06 75,22 l/s 98 dB(A) 5.350 x 1.710 x 1.5201.567 kW
| Water cooled Chiller & Heat Pump92
Selection guide Water Heat Pump
Product Range Heating Capacity COP Flow rate Acoustic Power
Size (LxHxW) mm
WQH
20-
190
WQH 20 23,7 kW 3,88 1,13 l/s 65 dB(A) 821 x
1.350 x 455
WQH 25 28,9 kW 3,85 1,38 l/s 67 dB(A) 821 x
1.350 x 455
WQH 30 33,6 kW 3,73 1,61 l/s 67 dB(A) 821 x
1.350 x 455
WQH 35 38,5 kW 3,79 1,84 l/s 68 dB(A) 821 x
1.350 x 455
WQH 40 42,9 kW 3,77 2,05 l/s 68 dB(A) 821 x
1.350 x 455
WQH 45 51,2 kW 3,85 2,45 l/s 70 dB(A) 821 x
1.350 x 455
WQH 50 57,7 kW 3,83 2,73 l/s 70 dB(A) 1.210 x
1.500 x 850
WQH 60 68,2 kW 3,81 3,23 l/s 70 dB(A) 1.210 x
1.500 x 850
WQH 75 86,3 kW 3,92 4,09 l/s 72 dB(A) 1.210 x
1.500 x 850
WQH 90 102,2 kW 3,89 4,84 l/s 73 dB(A) 1.210 x
1.500 x 850
WQH 120 132 kW 3,92 6,24 l/s 78 dB(A) 1.210 x
1.500 x 850
WQH 150 164,2 kW 3,95 7,78 l/s 81 dB(A) 1.210 x
1.500 x 850
WQH 170 190,1 kW 3,93 9 l/s 81 dB(A) 1.210 x
1.500 x 850
WQH 190 212,3 kW 3,93 10,05 l/s 81 dB(A) 1.210 x
1.500 x 850
WQH
524
-120
4
WQH 524 170,2 kW 3,85 8,1 l/s 81 dB(A) 2.250 x
1.845 x 850
WQH 604 201,1 kW 3,75 9,57 l/s 82 dB(A) 2.250 x
1.845 x 850
WQH 704 231,8 kW 3,85 11 l/s 85 dB(A) 2.250 x
1.845 x 850
WQH 804 256,5 kW 3,75 12,2 l/s 87 dB(A) 2.250 x
1.845 x 850
WQH 904 295,6 kW 3,82 14,1 l/s 89 dB(A) 2.250 x
1.845 x 850
WQH 1004 331 kW 3,94 15,8 l/s 90 dB(A) 2.250 x
1.845 x 850
WQH 1104 376,6 kW 3,94 18 l/s 90 dB(A) 2.250 x
1.845 x 850
WQH 1204 418,5 kW 3,94 20 l/s 90 dB(A) 2.250 x
1.845 x 850
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
93
Product Range Heating Capacity COP Flow rate Acoustic Power
Size (LxHxW) mm
SySc
rew
440
-155
0Wat
er E
VO H
P
SyScrew 440 Water EVO HP
487,7 kW 4,68 27,08 l/s 95 dB(A) 3.620 x 1.750 x 1.350
SyScrew 490 Water EVO HP
549,1 kW 4,75 30,64 l/s 95 dB(A) 3.620 x 1.750 x 1.350
SyScrew 570 Water EVO HP
634,6 kW 4,65 35,22 l/s 95 dB(A) 4.210 x 1.750 x 1.350
SyScrew 630 Water EVO HP
707,9 kW 4,61 39,19 l/s 95 dB(A) 4.210 x 1.750 x 1.350
SyScrew 700 Water EVO HP
791,9 kW 4,58 43,72 l/s 95 dB(A) 4.180 x 1.750 x 1.350
SyScrew 770 Water EVO HP
862,1 kW 4,65 47,81 l/s 95 dB(A) 4.180 x 1.750 x 1.350
SyScrew 860 Water EVO HP
960,2 kW 4,70 53,39 l/s 98 dB(A) 4.400 x 1.710 x 1.520
SyScrew 920 Water EVO HP
1.033,2 kW 4,71 57,50 l/s 98 dB(A) 4.400 x 1.710 x 1.520
SyScrew 990 Water EVO HP
1.109,2 kW 4,73 61,78 l/s 98 dB(A) 4.600 x 1.710 x 1.520
SyScrew 1070 Water EVO HP
1.189,3 kW 4,67 66,03 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1130 Water EVO HP
1.257 kW 4,63 69,61 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1220 Water EVO HP
1.359,9 kW 4,68 75,50 l/s 98 dB(A) 4.650 x 1.710 x 1.520
SyScrew 1280 Water EVO HP 1.426,9 kW 4,68 79,22 l/s 98 dB(A) 4.650 x
1.710 x 1.520
SyScrew 1400 Water EVO HP
4,53 87,72 l/s 98 dB(A) 5.350 x 1.710 x 1.520
SyScrew 1550 Water EVO HP
4,60 94,83 l/s 98 dB(A) 5.350 x 1.710 x 1.520
1.593,1 kW
1.714,6 kW
| Water cooled Chiller & Heat Pump94
WQL-WQH 20-190
Leaving water temperature (cooling)
Water °C from +5 to +18
Water + glycol °C -8 / +5 (with glycol + electronic expansion valve);+5/+18 (standard)
∆ T K from 3 to 8Only WQL-WQH 20-190Leaving water temperature (heating)
Water °C from +25 to +55
∆ T °C from 3 to 15
Power Supply V/Ph/Hz 400/3/50 (Nominal)
Note: maximum % glycol (ethylenic or propilenic): 40%.
Water Cooled Chiller, Heat Pump and Condensing WQL/WQH/WQRC 20-190
Technical features 14 sizes Cooling capacity from 21,2 to 192,7 kW Heating capacity from 23,7 to 212,3 kW 3 versions:
WQL (Cooling only) WQH (Heat pump) WQRC (Condenserless)
2 acoustic versions: BLN (Basic Low Noise)
ELN (Extra Low Noise) 2 frames:
F1 (size from 20 to 45) F2 (size from 50 to 190)
One refrigerant circuit One or two Scroll compressors Plate evaporator (AISI 316)
21-193 kW
Plate
Water cooled
Scroll
24-212 kW
R410A
Accessories and options BMS interface Compressors acoustic box (standard on ELN) Compressors jackets Desuperheater available for frame 2 Differential pressure switch (standard) Electronic expansion valve (standard WQRC 170-190) Hydrokit with 1 or 2 pumps for evaporator and condenser Mechanical gauges kit Power factor corrector capacitors Sequence phases control (standard) Sofstart Water filter Water flow switch
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182017
ErP2018
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
95
Technical performance
WQL 20-45 20 25 30 35 40 45Cooling capacity1 kW 21,2 26,2 31,1 34,8 39,2 46,6Input power1 kW 4,63 5,77 6,97 7,68 8,75 10,2EER1/ Energy efficiency class 4,58/C 4,54/C 4,46/C 4,53/C 4,48/C 4,57/CESEER 5,16 5,09 4,93 4,95 4,81 5,08SEER2 5,58 5,6 5,45 5,5 5,35 5,83
hsc2 215 216 210 212 206 225
Sound power level3/4* dB(A) 65/62 67/64 67/64 68/65 68/66 70/67Sound pressure level at 10 m3/4** dB(A) 34/31 36/33 36/33 37/34 38/35 39/36
WQH 20-45 20 25 30 35 40 45Cooling capacity1 kW 20,8 26,0 30,1 34,0 38,2 45,5Power input1 kW 4,67 5,82 7,03 7,82 8,80 10,4EER1/ Energy efficiency class 4,45/C 4,47/C 4,28/C 4,35/C 4,34/C 4,39/CESEER 4,95 5,03 4,80 4,86 4,67 4,86SEER2 5,13 5 4,88 5,1 5 5,48
hsc2 197 192 187 196 192 211
Heating capacity5 kW 23,7 28,9 33,6 38,5 42,9 51,2Power input5 kW 6,11 7,51 9,01 10,2 11,4 13,3COP5/ Energy efficiency class 3,88/C 3,85/C 3,73/D 3,79/D 3,77/D 3,85/CSCOP /Energy efficiency class 6 5,65 / A+++ 5,40 / A+++ 5,24 / A+++ 5,23 / A+++ 5,18/ A+++ 5,46 / A+++
hsh6 218 208 202 201 199 210
Sound power level3/4* dB(A) 65/62 67/64 67/64 68/65 68/66 70/67Sound pressure level at 10 m3/4** dB(A) 34/31 36/33 36/33 37/34 38/35 39/36
WQRC 20-45 20 25 30 35 40 45Cooling capacity7 kW 20,9 26,0 31,3 34,8 39,3 46,2Power input8 kW 4,54 5,61 6,37 7,24 8,15 9,89Sound power level3/4* dB(A) 65/62 67/64 67/64 68/65 68/66 70/67Sound pressure level at 10 m3/4** dB(A) 34/31 36/33 36/33 37/34 38/35 39/36
1 Cooling mode conditions: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C according to EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 BLN version. 4 ELN version.5 Data refers to 45°C leaving warm water temperature and 7°C condenser water temperature, according EN14511 standard.6 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.7 Data refered to evaporator water temperature 12/7°C and condenser water temperature 40°C. 8 Input power (only compressors).* Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Physical features
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 1½” 1½” 1½” 1½” 1½” 1½”Water connection (Condenser)Connection type VictaulicInlet/outlet diameter inch 1½˝ 1½” 1½” 1½” 1½” 1½”WeightOperating weight kg 162 182 179 185 191 214DimensionsLength mm 821 821 821 821 821 821Width mm 455 455 455 455 455 455Height mm 1.350 1.350 1.350 1.350 1.350 1.350
WQL 20-45 20 25 30 35 40 45
Internal heat exchangerConnection type VictaulicInlet/outlet diameter inch 1½” 1½” 1½” 1½” 1½” 1½”External heat exchangerConnection type VictaulicInlet/outlet diameter inch 1½˝ 1½” 1½” 1½” 1½” 1½”WeightOperating weight kg 165 187 184 190 195 219DimensionsLength mm 821 821 821 821 821 821Width mm 455 455 455 455 455 455Height mm 1.350 1.350 1.350 1.350 1.350 1.350
WQH 20-45 20 25 30 35 40 45
| Water cooled Chiller & Heat Pump96
Technical performance
WQRC 50-190 50 60 75 90 120 150 170 190Cooling capacity8 kW 51,2 61,7 77,8 91,4 118,7 147,6 169,4 193,2Power input7 kW 11,2 12,9 16,5 20,0 25,7 31,8 36,9 41,4Sound power level3/4* dB(A) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79Sound pressure level at 10 m3/4** dB(A) 39/37 39/37 41/39 42/40 47/45 50/48 50/48 50/48
1 Cooling mode conditions: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C according to EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 BLN version.4 ELN version.5 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 40°C/45°C according to EN14511 standard.6 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.7 Input power (only compressors).8 Data refered to evaporator water temperature 12/7°C and condenser temperature 40°C.* Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
WQL 50-190 50 60 75 90 120 150 170 190Cooling capacity1 kW 50,9 61,1 77,3 91,1 118,4 147,1 170,0 192,7Power input1 kW 11,9 13,6 17,3 20,8 26,6 33,0 37,8 42,7EER1/ Energy efficiency class 4,29/C 4,48/C 4,48/C 4,38/C 4,46/C 4,46/C 4,50/C 4,51/CESEER 5,68 5,95 5,53 5,92 5,58 5,38 5,38 5,41SEER2 5,9 6,125 6,075 6,2 6,125 6,375 5,95 6,7
hsc2 228 237 235 240 237 247 230 260
Sound power level3/4* dB(A) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79Sound pressure level at 10 m3/4** dB(A) 39/37 39/37 40/39 42/40 47/45 50/48 50/48 50/48
WQH 50-190 50 60 75 90 120 150 170 190Cooling capacity1 kW 49,9 58,9 76,1 88,6 114,9 144,3 165,7 185,4Power input1 kW 12,0 13,9 17,5 21,1 27,0 33,3 38,2 43,3EER1/ Energy efficiency class 4,15/D 4,24/D 4,36/C 4,20/D 4,26/C 4,34/C 4,34/C 4,28/CESEER 5,48 5,62 5,43 5,60 5,25 5,22 5,31 5,09SEER2 4,7 4,88 4,47 4,83 4,93 4,97 5,65 5,1
hsc2 180 187 171 185 189 191 218 196
Heating capacity5 57,7 68,2 86,3 102,2 132,0 164,2 190,1 212,3Power input5 kW 15,1 17,9 22,0 26,3 33,7 41,6 48,4 54,0COP5/ Energy efficiency class kW 3,83/D 3,81/D 3,92/C 3,89/C 3,92/C 3,95/C 3,93/C 3,93/C
SCOP /Energy efficiency class6 5,06 / A+++
5,57 / A+++
5,28 / A+++
5,05 / A+++
5,50 / A+++
5,12 / A+++
5,21 / A+++
5,34 / A+++
hsh6 194 215 203 194 212 197 200 205
Sound power level3/4* dB(A) 70/68 70/68 72/70 73/71 78/76 81/79 81/79 81/79Sound pressure level at 10 m3/4** dB(A) 39/37 39/37 40/39 42/40 47/45 50/48 50/48 50/48
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 1½” 1½” 1½” 1½” 1½” 1½”Remote condenser refrigerant connectionsConnection type To be brazedInlet diameter inch ⅝” ⅝” ⅝” ⅝” ⅝” ⅝”Outlet diameter inch ⅝” ⅞” ⅞” ⅞” ⅞” ⅞”WeightOperating weight kg 144 164 166 166 172 172DimensionsLength mm 821 821 821 821 821 821Width mm 455 455 455 455 455 455Height mm 1.350 1.350 1.350 1.350 1.350 1.350
WQRC 20-45 20 25 30 35 40 45
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
97
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½” 2½” 2½”Water connection (Condenser)Connection type VictaulicInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½” 2½” 2½”WeightOperating weight kg 352 371 392 411 597 666 701 745DimensionsLength mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210Width mm 850 850 850 850 850 850 850 850Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500
WQL 50-190 50 60 75 90 120 150 170 190
Internal heat exchangerConnection type VictaulicInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½” 2½” 2½”External heat exchangerConnection type VictaulicInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½” 2½” 2½”WeightOperating weight kg 360 379 403 422 610 683 718 762DimensionsLength mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210Width mm 850 850 850 850 850 850 850 850Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500
Physical feature
WQH 50-190 50 60 75 90 120 150 170 190
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 2½” 2½” 2½” 2½” 2½” 2½” 2½” 2½”Remote condenser refrigerant connectionsConnection type To be brazedInlet diameter inch ⅝” ⅝” ⅞” ⅞” ⅞” ⅞” 1⅛” 1⅛”Outlet diameter inch ⅞” ⅞” 1⅛” 1⅛” 1⅜” 1⅝” 1⅝” 1⅝”WeightOperating weight kg 332 344 365 376 558 612 643 674DimensionsLength mm 1.210 1.210 1.210 1.210 1.210 1.210 1.210 1.210Width mm 850 850 850 850 850 850 850 850Height mm 1.500 1.500 1.500 1.500 1.500 1.500 1.500 1.500
WQRC 50-190 50 60 75 90 120 150 170 190
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Water cooled Chiller & Heat Pump98
Water Cooled Chiller & Heat PumpWQL/WQH/WQRC 524-1604
Technical features WQL 10 sizes and 8 WQH&WQRC Cooling capacity from 154,3 to 478,4 kW Heating capacity from 170,2 to 418,5 kW 3 versions:
WQL (Cooling only) WQH (Heat pump) WQRC (Condenserless)
2 acoustic versions: BLN (Basic Low Noise) ELN (Extra Low Noise)
Two refrigerant circuits Four scroll compressors (tandem) Plate evaporator (AISI 316)
WQL 524-1604 - WQH 524-1204
Leaving water temperature(cooling)
Water °C from +5 to +18
Water + glycol °C -8 / +5 (with glycol and electronic expansion valve);+5/+18 (standard)
∆ T K from 3 to 8
Leaving water temperature(heating)
Water °C from +25 to +55∆ T °C from 3 to 15
Power Supply V/Ph/Hz 400/3/50 (Nominal)
Note: maximum % glycol (ethylenic or propilenic): 40%.
154-478 kW
Plate
Water cooled
Scroll
170-419 kW
R410A
Accessories and options Desuperheater Differential pressure switch (standard) Electronic expansion valve (standard WQRC 1104-1204) Hydrokit with 1 or 2 pumps for evaporator and condenser Mechanical gauges Sequence phases control (standard) Softstart Water filter Water flow switch
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
ErP20182017
ErP2018
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
99
Technical performance
WQL 524-1604 524 604 704 804 904 1004 1104 1204 1404 1604Cooling capacity1 kW 154,3 181,8 208,9 232,6 265,8 295,6 338,0 379,2 429,1 478,4Input power1 kW 34,2 41,6 47,5 53,3 59,3 65,5 74,9 83,3 95,1 107,4EER1/ Energy efficiency class kW/kW 4,51/C 4,37/C 4,40/C 4,36/C 4,48/C 4,51/C 4,51/C 4,55/C 4,51/C 4,45/CESEER kW/kW 5,40 5,68 5,81 5,29 5,74 5,52 5,70 5,67 5,32 4,97SEER2 5,55 6,28 6,1 5,75 6,1 6,1 6,2 6,25 6,2 5,88
hsc2 214 243 236 222 236 236 240 242 240 227
Sound power level3/4* dB(A) 81/75 82/76 85/79 87/81 89/83 90/84 90/84 90/84 90/84 90/84Sound pressure level at 10 m3*/4** dB(A) 49/43 50/44 53/47 55/49 57/51 58/52 58/52 58/52 58/52 58/52
1 Cooling mode conditions: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C according to EN14511 standard.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 BLN version. 4 ELN version.5 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 40°C/45°C according to EN14511 standard.6 Following COMMISSION REGULATION (EU) No 813/2013 for low-temperature heat pumps.7 Evaporator EWT/LWT 12 °C/7 °C, condensing temperature 50 °C.8 Only for handling.* Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.** Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Water connection (Evaporator)Type VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 4” 4” 4” 4” 4” 4”Water connection (Condenser)Type VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 4” 4” 4” 4” 4” 4”WeightOperating weight BLN kg 890 971 1.156 1.329 1.340 1.453 1.552 1.660 1.668 1.716Operating weight ELN kg 993 1.074 1.259 1.432 1.443 1.556 1.655 1.763 1.791 1.819DimensionsLength mm 2.250Width mm 8503/8544/ 8853/8 - 1.0054/8
Height mm 1.8453/ 1.8504
WQH 524-1204 524 604 704 804 904 1004 1104 1204Cooling capacity1 kW 150,7 176,2 204,5 225,4 263,1 291,3 332,0 370,5Input power1 kW 34,9 42,7 48,3 54,3 59,8 66,4 76,2 85,2EER1/ Energy efficiency class kW/kW 4,32/C 4,13/D 4,23/D 4,15/D 4,40/C 4,39/C 4,36/C 4,35/CESEER kW/kW 5,35 5,59 5,71 5,25 5,66 5,46 5,63 5,59SEER2 4,65 4,93 4,93 4,68 5,15 5,1 5,28 5,3
hsc2 178 189 189 179 198 196 203 204
Heating capacity5 kW 170,2 201,1 231,8 256,5 295,6 331,0 376,6 418,5Input power5 kW 44,2 53,6 60,2 68,4 77,4 84,0 95,6 106,2COP5/ Energy efficiency class kW/kW 3,85/C 3,75/D 3,85/C 3,75/D 3,82/C 3,94/C 3,94/C 3,94/C
SCOP /Energy efficiency class6 5,19 / A+++
5,31 / A+++
5,25 / A+++
5,14 / A+++
5,56 / A+++
5,52 / A+++
5,76 / A+++
5,54 / A+++
hsh6 200 204 202 198 214 213 222 214
Sound power level3/4* dB(A) 81/75 82/76 85/79 87/81 89/83 90/84 90/84 90/84Sound pressure level at 10 m3*/4** dB(A) 49/43 50/44 53/47 55/49 57/51 58/52 58/52 58/52
WQRC 524-1204 524 604 704 804 904 1004 1104 1204Cooling capacity7 kW 130,0 155,3 177,6 196,5 224,2 247,2 285,9 316,1Input power7 kW 42,9 51,1 59,0 65,8 74,4 82,5 94,6 105,8Sound power level3*/4** dB(A) 81/75 82/76 85/79 87/81 89/83 90/84 90/84 90/84Sound pressure level at 10 m3*/4** dB(A) 49/43 50/44 53/47 55/49 57/51 58/52 58/52 58/52
Physical features
WQL 524-1604 524 604 704 804 904 1004 1104 1204 1404 1604
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Water cooled Chiller & Heat Pump100
Internal heat exchanger water connectionsType VictaulicInlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 4” 4” 4” 4”Remote condenser refrigerant connectionsType To be brazedInlet diameter inch 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8” 1 1/8” 1 1/8” 1 1/8”Outlet diameter inch 1 1/8” 1 1/8” 1 3/8” 1 3/8” 1 5/8” 1 5/8” 1 5/8” 1 5/8”WeightOperating weight BLN kg 770 812 988 1.163 1.188 1.241 1.328 1.388Operating weight ELN kg 873 915 1.091 1.266 1.291 1.344 1.431 1.491DimensionsLength mm 2.250Width mm 8501/8542/8851/3- 1.0052/3
Height mm 1.8451/1.8502
Physical feature
Internal heat exchangerType VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 4” 4” 4” 4”External heat exchangerType VictaulicInlet/outlet diameter inch 2”1/2 2”1/2 2”1/2 2”1/2 4” 4” 4” 4”WeightOperating weight BLN kg 909 989 1.187 1.360 1.376 1.500 1.598 1.704Operating weight ELN kg 1.012 1.092 1.290 1.463 1.479 1.603 1.701 1.807DimensionsLength mm 2.250Width mm 8501/8542/8851/3- 1.0052/3
Height mm 1.8451/1.8502
WQH 524-1204 524 604 704 804 904 1004 1104 1204
WQRC 524-1204 524 604 704 804 904 1004 1104 1204
1 BLN version. 2 ELN version.3 Only for handling.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
101
Hotel Catalonia Brussel, Belgium
Site: HotelProduct: Air cooled chiller SysAqua 190 Air Application: Air conditioning
| Water cooled Chiller & Heat Pump102
Water Cooled ChillerSyScrew 440-1550 Water EVO CO/HP/RC
Technical features 15 sizes Cooling capacity from 444 to 1.567 kW 3 versions:
CO (chiller) HP (heat pump) water side RC (condenserless)
2 acoustic versions: STD (Standard) S (Super Low Noise)
1/2 refrigerant circuit Screw compressors Shell & Tube evaporator and condenser Electronic expansion valve
Models SyScrew Water EVO CO
SyScrew Water EVO HP
SyScrew Water EVO RC
Evaporator Leaving watertemperature
Water °C from 5 to 15Water + glycol °C from -8 to 5∆ T K from 3 to 7
Condenser
Leaving water temperature °C from 25 to 45 from 25 to 60 -Condensing Temperature °C - - from 30 to 63
Leaving water + glycol temperature K from +3 to +8 with tower water15 with well water -
Power Supply V/Ph/Hz 400/3/50 (Nominal)
444-1.567 kW Shell & Tube
Water cooled Screw
R134a
Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard for S version) Compressor stepless control Mechanical gauges Power factor corrector capacitors Sequence phases control (standard) Softstart Water filter Water flow switch
ErP2018
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
103
Technical performance
SyScrew 440-770 Water EVO CO 440 490 570 630 700 770Cooling capacity1 kW 444,3 494,4 570,4 636,2 708,5 787,1Power input1 kW 87,9 97,8 112,4 125,4 140,2 155,7EER1/ Energy efficiency class 5,06/A 5,05/A 5,07/A 5,07/A 5,05/A 5,06/AESEER 6,27 6,27 6,29 6,29 6,27 6,27SEER2 5,9 5,925 6,2 6,125 5,975 6,3
hsc2 228 229 240 237 231 244
Sound power level STD3 dB(A) 95 95 95 95 95 95Sound pressure level at 10 m STD4 dB(A) 76 76 76 76 76 76Sound power level S3 dB(A) 85 85 85 85 85 85Sound pressure level at 10 m S4 dB(A) 66 66 66 66 66 66
1 Cooling mode conditions: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT 30°C/35°C.2 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.5 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 40°C/45°C.6 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 47°C/55°C.7 NET value. According to standard EN 14511-3:2011.
SyScrew 440-770 Water EVO HP 440 490 570 630 700 770Cooling Capacity5 7 kW 383,4 433,6 498,1 554,5 619,1 676,8Power input5 7 kW 104,3 115,6 136,4 153,4 172,8 185,2Heating Capacity5 7 kW 487,7 549,1 634,6 707,9 791,9 862,1COP5 7/ Energy efficiency class 4,68/A 4,75/A 4,65/A 4,61/A 4,58/A 4,65/ASEER2 5,95 6,00 6,00 5,875 5,925 5,925
hsc2 230 232 232 227 229 229
Cooling Capacity6 7 kW 339,5 383,8 441,3 491,4 548,0 599,1Total Input Power6 7 kW 117,1 130,3 152,2 172,0 195,5 208,9Heating Capacity6 7 kW 456,6 514,1 593,5 663,4 743,5 808,0COP6 7 3,90 3,95 3,90 3,86 3,80 3,87Sound Power level STD3 dB(A) 95 95 95 95 95 95Sound Pressure level at 10 m STD4 dB(A) 76 76 76 76 76 76Sound Power Level S3 dB(A) 85 85 85 85 85 85Sound Pressure Level at 10 m S4 dB(A) 66 66 66 66 66 66
SyScrew 440-770 Water EVO RC 440 490 570 630 700 770Cooling capacity1 kW 386,3 435,7 502,8 561,0 621,9 680,6Power input1 kW 101,2 113,3 131,4 147,4 170,4 181,5EER1 3,82 3,85 3,83 3,81 3,65 3,75Sound power level STD3 dB(A) 95 95 95 95 95 95Sound pressure level at 10 m STD4 dB(A) 76 76 76 76 76 76Sound power level S3 dB(A) 85 85 85 85 85 85Sound pressure level at 10 m S4 dB(A) 66 66 66 66 66 66
Physical feature
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 6" 6" 6" 6" 8" 8"Water connection (Condenser)Connection type Female gas threadedInlet/outlet diameter inch 4" 4" 5" 5" 5" 5"WeightOperating weight STD kg 2.683 2.718 2.911 3.033 3.516 3.590Operating weight S kg 2.863 2.898 3.091 3.213 3.696 3.770DimensionsLength mm 3.620 3.620 4.210 4.210 4.180 4.180Width mm 1.350 1.350 1.350 1.350 1.350 1.350Height mm 1.650 1.650 1.650 1.650 1.650 1.650Height S mm 1.750 1.750 1.750 1.750 1.750 1.750
SyScrew 440-770 Water EVO CO 440 490 570 630 700 770
| Water cooled Chiller & Heat Pump104
Internal heat exchanger (Evaporator)Connection type VictaulicInlet/outlet diameter inch 6" 6" 6" 6" 8" 8"External heat exchanger (Condenser)Connection type VictaulicInlet/outlet diameter inch 4" 4" 5" 5" 5" 5"WeightOperating weight STD kg 2.690 2.725 2.918 3.040 3.523 3.597Operating weight S kg 2.884 2.919 3.112 3.234 3.717 3.791DimensionsLength mm 3.620 3.620 4.210 4.210 4.180 4.180Width mm 1.350 1.350 1.350 1.350 1.350 1.350Height mm 1.650 1.650 1.650 1.650 1.650 1.650Height S mm 1.750 1.750 1.750 1.750 1.750 1.750
SyScrew 860-1550 Water EVO HP 860 920 990 1070 1130 1220 1280 1400 1550Cooling Capacity1 4 kW 755,9 813,8 874,6 934,6 985,3 1.069,6 1.122,1 1.241,5 1.341,5Power Input1 4 kW 204,3 219,4 234,6 254,7 271,7 290,3 304,8 351,6 373,1Heating Capacity1 4 kW 960,2 1.033,2 1.109,2 1.189,3 1.257,0 1.359,9 1.426,9 1.593,1 1.714,6COP1 4/ Energy efficiency class 4,70/A 4,71/A 4,73/A 4,67/A 4,63/A 4,68/A 4,68/A 4,53/A 4,60/ASEER3 5,925 5,9 5,875 6,525 6 5,925 5,9 5,9 5,95
hsc3 229 228 227 253 232 229 228 228 230
Cooling Capacity2 4 kW 669,3 720,7 774,4 827,8 872,7 946,6 993,3 1.100,0 1.189,1Total Input Power2 4 kW 230,2 246,6 264,0 286,2 305,1 327,7 343,8 395,2 417,5Heating Capacity2 4 kW 899,5 967,3 1.038,4 1.114,0 1.177,8 1.274,3 1.337,1 1.495,2 1.606,6COP2 4 3,91 3,92 3,93 3,89 3,86 3,89 3,89 3,78 3,85Sound power level STD5 dB(A) 98 98 98 98 98 98 98 98 98Sound pressure level at 10 m STD6 dB(A) 79 79 79 79 79 79 79 79 79Sound power level S5 dB(A) 89 89 89 89 89 89 89 89 89Sound pressure level at 10 m S6 dB(A) 70 70 70 70 70 70 70 70 70
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 6" 6" 6" 6" 8" 8"Remote condenser refrigerant connectionsConnection type To be brazedInlet diameter circuit 1 inch 1.5/8" 1.5/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8"Outlet diameter circuit 1 inch 3.1/8" 3.1/8" 3.5/8" 3.5/8" 4.1/8" 4.1/8"WeightOperating weight STD kg 2.295 2.305 2.449 2.469 2.945 2.985Operating weight kg 2.475 2.485 2.629 2.649 3.125 3.165DimensionsLength mm 3.620 3.620 4.210 4.210 4.180 4.180Width mm 1.350 1.350 1.350 1.350 1.350 1.350Height mm 1.650 1.650 1.650 1.650 1.650 1.650Height S mm 1.750 1.750 1.750 1.750 1.750 1.750
SyScrew 440-770 Water EVO HP 440 490 570 630 700 770
SyScrew 440-770 Water EVO RC 440 490 570 630 700 770
SyScrew 860-1550 Water EVO CO 860 920 990 1070 1130 1220 1280 1400 1550Cooling capacity7 kW 875,5 936,0 998,6 1.071,4 1.132,9 1.224,1 1.285,2 1.428,5 1.567,0Power input7 kW 173,1 185,2 197,6 211,7 223,8 241,0 253,9 282,4 309,9EER7/ Energy efficiency class 5,06/A 5,05/A 5,05/A 5,06/A 5,06/A 5,08/A 5,06/A 5,06/A 5,06/AESEER 6,37 6,37 6,39 6,42 6,42 6,43 6,37 6,38 6,38SEER3 5,925 5,925 5,9 6,35 5,95 5,95 5,9 5,875 6
hsc3 229 229 228 246 230 230 228 227 232
Sound power level STD5 dB(A) 98 98 98 98 98 98 98 98 98Sound pressure level at 10 m STD6 dB(A) 79 79 79 79 79 79 79 79 79Sound power level S5 dB(A) 89 89 89 89 89 89 89 89 89Sound pressure level at 10 m S6 dB(A) 70 70 70 70 70 70 70 70 70
Technical performance
1 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 40°C/45°C.2 Heating mode conditions: evaporator EWT/LWT 10°C/7°C, condenser EWT/LWT 47°C/55°C.3 Following COMMISSION REGULATION (EU) No 2016/2281 for comfort application chillers.4 NET value According to standard EN 14511-3:2011.5 Sound power levels refers to standard ISO 3744 and Eurovent 8/1 for units certified. Units at fully loaded conditions.6 Sound pressure levels refers to unit in free field on refletive surface at 1m. Values derived from sound power levels (standard ISO 3744 with parallepiped shape).7 Cooling mode conditions: evaporator EWT/LWT 12°C/7°C, condenser EWT/LWT30°C/35°C.
Water cooled Chiller & Heat Pump |
WAT
ER C
OOLE
D CH
ILLE
R &
HEAT
PUM
P
105
SyScrew 860-1550 Water EVO RC 860 920 990 1070 1130 1220 1280 1400 1550Cooling capacity1 kW 760,8 820,0 880,4 941,7 993,6 1.074,2 1.127,6 1.253,8 1.357,3Power input1 kW 199,5 213,2 228,7 247,5 263,2 285,5 299,1 340,5 357,8EER1 3,81 3,85 3,85 3,80 3,77 3,76 3,77 3,68 3,79Sound power level STD2 dB(A) 98 98 98 98 98 98 98 98 98Sound pressure level at 10 m STD3 dB(A) 79 79 79 79 79 79 79 79 79Sound power level S2 dB(A) 89 89 89 89 89 89 89 89 89Sound pressure level at 10 m S3 dB(A) 70 70 70 70 70 70 70 70 70
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 8" 8" 10" 10" 10" 10" 10" 10" 10"Water connection (Condenser)Connection type Female gas threadedInlet/outlet diameter inch 4" 4" 4" 4/5" 5" 5" 5" 5" 5"WeightOperating weight STD kg 5.540 5.576 5.787 5.909 6.016 6.087 6.136 6.754 6.849Operating weight S kg 5.900 5.936 6.147 6.269 6.376 6.447 6.496 7.114 7.209DimensionsLength mm 4.400 4.400 4.600 4.650 4.650 4.650 4.650 5.350 5.350Length S mm 4650 4650 4650 4650 4650 4.650 4.650 5400 5400Width mm 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520Height mm 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710Height S mm 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770
SyScrew 860-1550 Water EVO CO 860 920 990 1070 1130 1220 1280 1400 1550
Internal heat exchanger (Evaporator)Connection type VictaulicInlet/outlet diameter inch 8" 8" 10" 10" 10" 10" 10" 10" 10"External heat exchanger (Condenser)Connection type VictaulicInlet/outlet diameter inch 4" 4" 4" 4/5" 5" 5" 5" 5" 5"WeightOperating weight STD kg 5.579 5.615 5.826 5.948 6.055 6.126 6.175 6.793 6.888Operating weight S kg 5.966 6.002 6.213 6.335 6.442 6.513 6.562 7.180 7.275DimensionsLength mm 4.400 4.400 4.600 4.650 4.650 4.650 4.650 5.350 5.350Length S mm 4650 4650 4650 4650 4650 4.650 4.650 5400 5400Width mm 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520Height mm 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710Height S mm 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770
SyScrew 860-1550 Water EVO HP 860 920 990 1070 1130 1220 1280 1400 1550
Water connection (Evaporator)Connection type VictaulicInlet/outlet diameter inch 8" 8" 10" 10" 10" 10" 10" 10" 10"Remote condenser refrigerant connectionsConnection type To be brazedInlet diameter circuit 1 inch 1.5/8" 1.5/8" 1.5/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8"Outlet diameter circuit 1 inch 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 4.1/8" 4.1/8"Inlet diameter circuit 2 inch 1.5/8" 1.5/8" 1.5/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8" 2.1/8"Outlet diameter circuit 2 inch 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 3.1/8" 4.1/8" 4.1/8"WeightOperating weight STD kg 4.765 4.775 4.959 5.032 5.092 5.131 5.151 5.557 5.637Operating weight S kg 5.125 5.135 5.319 5.392 5.452 5.491 5.511 5.917 5.997DimensionsLength mm 4.400 4.400 4.600 4.650 4.650 4.650 4.650 5.350 5.350Length S mm 4650 4650 4650 4650 4650 4.650 4.650 5400 5400Width mm 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520 1.520Height mm 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710 1.710Height S mm 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770 1.770
SyScrew 860-1550 Water EVO RC 860 920 990 1070 1130 1220 1280 1400 1550
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Physical features
| Water cooled Chiller & Heat Pump106
Galleria Santa Lucia TunnelBarberino del Mugello, Italy
Site: Highway tunnelProduct: Air cooled chiller SyScroll Air 660Application: Water cooled system
| Free-cooling108
Technical features 10 sizes Cooling capacity from 100 to 550 kW Free-cooling option is developed in 2 versions:
Slave Stand-alone
2 acoustic versions: - (Basic Low Noise) L (Low Noise)
2 fans versions: EC Version (Inverter Fans) HPF Version (High Pressure Fans)
Free-cooling moduleSysFreeCool
SysFreeCool 12 14 22 23 24 32 33 34 43 44
BrineMinimum temperature1 °C -10Maximum operating pressure bar 6
AmbientOutdoor air temperature °C from -20 to +50
External static pressure
Standard fans Pa 0High pressure fans(HPF) Pa < 120
Power supply2 V/Ph/Hz 400/3/50 (Nominal)
1 Liquid with appropriate % of glycol.2 Voltage 400V +/- 10%.
100-550 kW Free-cooling
Accessories and options Automatic circuit breaker Brushless fan motors (EC Version) Coil grilles Coils with cooper fins E-coating for AL/CU fins Fan speed control as standard Free-cooling grilles High static pressure fan motors (HPF Version) Hour meter as standard Main switch ModBus protocol kit Power supply without neutral Remote keyboard panel Remote ON/OFF control Sequence phase control as standard Set point timer/clock card as standard Water filter
Operating limits (to be confirmed with SysofAC - www.sysoftac.com) www.sysoftac.com
Free-cooling |
FREE
-COO
LING
109
Configuration
Following modules are available in order to cover a wide capacity range: 1V: equipped with two coils and two fan motors 2V: equipped with four coils and four fan motors 3V: equipped with six coils and six fan motors 4V: equipped with eight coils and eight fan motors
Each module is be available in further versions, according coil row number, sound level emission.
Following table is summarizing allowed combination be-tween free-cooling modules and SyScroll Air range.The table is valid for Slave version.
SyScroll Air CO Free-cooling module SyScroll Air FC
Assembly view Size Assembly view Size Assembly view
240270290320
232432
360420
3334
470540
3334
590660
4344
+ =
SyScroll Air EVO CO Free-cooling module SyScroll Air EVO FC
Assembly view Size Assembly view Size Assembly view
200 22
230260280
232432
300330360
2324
+ =
V VV VVV VVVV
Stand-alone Slave / Stand-alone
85 200 300 400 550
Cooling Capacity (kW)
Following picture is showing cooling capacity field where it is possible to have stand-alone, slave or both configuration.
| Free-cooling110
Technical performance
Water ConnectionsType Male gas threadedInlet Diameter inch 2” 1/2 2” 1/2 2” 1/2 3” 3”Outlet Diameter inch 2” 1/2 2” 1/2 2” 1/2 3” 3”WeightOperating weight kg 669 733 1.002 1.075 1.139DimensionsLength mm 2.146 2.124Width mm 1.097 2.146Height mm 2.519 2.519
Water ConnectionsType Male gas threaded VictaulicInlet Diameter inch 3” 4” 4” 5” 5”Outlet Diameter inch 3” 4” 4” 5” 5”WeightOperating weight kg 1.466 1.574 1.670 2.070 2.198DimensionsLength mm 3.176 4.228Width mm 2.146 2.146Height mm 2.519 2.519
Physical features
1 Data refers to 15 (°C) return brine temperature, 10 (°C) leaving brine temperature, 0 (°C) outdoor air temperature; 30% EG.2 Sound levels are at fully loaded conditions. Sound power level values refer to ISO standard 3744.3 Sound pressure levels refer to ISO Standard 3744, parallelepiped shape.
SYSFREECOOL_ - (STD -HPF) 12 14 22 23 24Nominal capacity1 kW 101 156 206 245 275Nominal Water Flow m3/h 19,0 29,4 38,7 46,0 51,7Total pressure drop1 kPa 44 83 74 43 49Sound power level2 dB(A) 88 88 91 91 91Sound pressure level at 10 m3 dB(A) 56 56 59 59 59
SYSFREECOOL_ L- (STD -HPF) 12 14 22 23 24Nominal capacity1 kW 84,4 123,5 170,3 197,0 215,9Nominal Water Flow m3/h 15,9 23,2 32,0 37,0 40,6Total pressure drop1 kPa 31 52 50 28 30Sound power level2 dB(A) 79 79 82 82 82Sound pressure level at 10 m3 dB(A) 47 47 50 50 50
SYSFREECOOL_ (STD -HPF) 12 14 22 23 24
Technical performanceSYSFREECOOL_ - (STD -HPF) 32 33 34 43 44Nominal capacity1 kW 309 367 413 490 550Nominal Water Flow m3/h 58,0 69,0 77,5 92,0 103,4Total pressure drop1 kPa 70 51 57 43 49Sound power level2 dB(A) 93 93 93 94 94Sound pressure level at 10 m3 dB(A) 61 61 61 62 62
SYSFREECOOL_ L- (STD -HPF) 32 33 34 43 44Nominal capacity1 kW 255,4 295,5 323,8 394,0 431,8Nominal Water Flow m3/h 48,0 55,5 60,8 74,0 81,1Total pressure drop1 kPa 48 33 35 28 30Sound power level2 dB(A) 84 84 84 85 85Sound pressure level at 10 m3 dB(A) 52 52 52 53 53
Physical featuresSYSFREECOOL_ (STD -HPF) 32 33 34 43 44
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Condensing unit |
COND
ENSI
NG U
NIT
111
Condensing unit
VLC 604-1204 174-347 kW R410A ScrollPage 124
SyScroll 240-660 Air RE 266-727 kW R410A ScrollPage 126
SyScroll 40-75 Air RE 43-85 kW R410A ScrollPage 114
SyScroll 85-135 Air RE 94-142 kW R410A ScrollPage 118
AQVC 85-140 92-151 kW R410A ScrollPage 120
SyScroll 140-360 Air RE 165-395 kW R410A ScrollPage 122
SysAqua 25-125RE
32-136 kW R410A ScrollPage 116
SyScroll 20-35 Air RE 22-36 kW R410A ScrollPage 112
| Condensing unit112
SyScroll 20-35 Air REEvaporating temperature2 °C from -12 to +14Ambient Air temperature °C from -10 to 50Power supply V/Ph/Hz 400/3/50 (Nominal)
Condensing unitSyScroll 20-35 Air RE
Technical features 4 sizes Cooling capacity from 22,1 to 36,2 kW One scroll compressor New control Scroll compressors
22-36 kW
Air cooled
Scroll
R410A
Accessories and options Automatic circuit breaker (standard) Coil grilles Coils treatment Desuperheater Fan speed control (standard) Power factor corrector capacitors Sequence phases control (standard) Softstart
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
113
Technical performance
SyScroll 20-35 Air RE 20 25 30 35Cooling Capacity 1 kW 22,1 26,4 29,9 36,2Input Power kW 7,23 7,96 9,56 12,3Sound Power Level dB(A) 73 74 74 75Sound Pressure Level at 10 m* dB(A) 41 42 42 43
1 Data refers to 7°C evaporating temperature and 35°C condenser inlet air temperature.* Sound pressure level at 10 m.- Values refers to ISO Standard 3744 with parallepiped shape.
Refrigerant connectionType To be brazedLiquid diameter inch 1”1/2WeightShipping weight kg 228 259 263 278DimensionsLength mm 1.477 1.477 1.477 1.477Width mm 539 539 539 539Height mm 1.615 1.615 1.615 1.615
Physical features
SyScroll 20-35 Air RE 20 25 30 35
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit114
SyScroll 40-75 Air REEvaporating limit °C from -13 to 14
Ambient Air temperature
- °C from -18 to 44S °C from -18 to 40
HPF °C from -20 to 47 (40-50)from -20 to 50 (60-75)
Power supply V/Ph/Hz 400/3/50 (Nominal)
Condensing unitSyScroll 40-75 Air RE
Technical features 6 sizes Cooling capacity from 43,2 to 84,5 kW 2 versions:
STD (Standard) HPF (High Pressure Fans)
2 acoustic versions: - (Basic Low Noise) S (Extra Low Noise)
One refrigerant circuit Scroll compressors
43-85 kW
Air cooled
Scroll
R410A
Accessories and options Automatic circuit breaker Coils treatments Compressors acoustic box as standard Compressors jackets (standard on S) Desuperheater Fan speed control (standard) Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles (standard)
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
115
Technical performance
SyScroll 40-75 Air RE 40 45 50 60 65 75Cooling capacity1 kW 43,2 48,8 56,9 67,4 73,8 84,5Power input1 kW 13,0 15,3 17,8 18,7 21,6 26,3Sound power level2 dB(A) 79 79 79 84 84 84Sound pressure level at 10 m3 dB(A) 48 48 48 52 52 52
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
Refrigerant connectionType To be brazedInlet diameter inch ⅝” ⅝” ⅝” ⅞” ⅞” ⅞”Outlet diameter inch 1⅜” 1⅜” 1⅜” 1⅜” 1⅜” 1⅜”WeightShipping weight kg 391 399 422 456 466 469DimensionsLength mm 1.750 1.750 1.750 2.200 2.200 2.200Width mm 1.100 1.100 1.100 1.100 1.100 1.100Height mm 1.580 1.580 1.580 1.580 1.580 1.580Height HPF mm 1.685 1.685 1.685 1.685 1.685 1.685
SyScroll 40-75 Air RE S 40 45 50 60 65 75Cooling capacity1 kW 41,6 46,7 54,0 64,9 70,7 80,6Power input1 kW 13,7 16,3 19,1 19,7 22,8 28,1Sound power level2 dB(A) 74,0 75,3 75,3 78,0 78,5 79,0Sound pressure level at 10 m3 dB(A) 42,4 43,7 43,7 46,3 46,8 47,3
SyScroll 40-75 Air RE HPF 40 45 50 60 65 75Cooling capacity1 kW 45,8 52,1 61,3 68,4 75,2 85,9Power input1 kW 11,9 13,9 16,0 18,3 21,1 25,6
Physical features
SyScroll 40-75 Air RE 40 45 50 60 65 75
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit116
Condensing unitSysAqua 25-125 RE
Technical features Cooling only 32 to 136 kW R410A refrigerant Units are optimized for partial load operation High ESEER 2 compressors fitted in tandem for all the range with two
capacity steps Sizes 25 to 125, three capacity steps with an immediate return
on investment versus the inverter units Low noise version supplied as standard, extra low noise
version for the XLS units (SysAqua RE 45-125 only) Refrigerant circuit is completely closed in a separate
compartment in order to reduce noise level (sizes 25 to 40) Great accessibility to internal components for service
maintenance Wide operating limits Fan speed control for low ambient operation in cooling mode
down to -10 °C as STD Phase sequence monitor supplied as standard Small footprint, allowing shipping and handling costs to be
saved, units find easily a place to be installed Suction and liquid line shut-off valve as STD. Ideal to be
connected with air handling unit
32-136 kW
Air cooled R410A
Scroll
SysAqua 25-125 REEvaporating limits °C from -12 to 14Ambient air temperature °C from -10 to 50Power supply V/Ph/Hz 400/3/50 (Nominal)
Accessories and options Anti-vibration rubber pads Coil with epoxy treatment Condenser protective grid LP/HP gauges Power supply without neutral kit Reinforced acoustic insulation (XLS version) Soft starter
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
117
SysAqua 25-45 RE 25 30 35 40 45Cooling capacity 1 kW 32,5 33,7 43,1 44,8 57,3Power input 1 kW 9,1 9,8 13,9 14,1 17,4Total EER 100%1 3,57 3,44 3,10 3,18 3,29Sound power level dB(A) 75 75 76 76 80
Technical performance
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard.
Refrigerant ConnectionsLiquid line inch 5/8” 5/8” 5/8” 5/8” 5/8”Suction line inch 1”1/8 1”1/8 1”1/8 1”1/8 1”5/8WeightOperating weight kg 260 270 280 280 490DimensionsLength mm 1.000 1.000 1.000 1.000 2.180Width mm 1.000 1.000 1.000 1.000 1.160Height mm 1.983 1.983 1.983 1.983 1.986
SysAqua 55-125 RE 55 65 75 90 105 125Cooling capacity 1 kW 64,5 72,3 79,3 103,9 119,6 136,4Power input 1 kW 20,2 22,5 25,3 35 38,8 47,1Total EER 100%1 3,19 3,21 3,13 2,97 3,08 2,89Sound power level dB(A) 79 79 79 82 82 82
Physical features
SysAqua 25-45 RE 25 30 35 40 45
Refrigerant connectionsLiquid line inch 5/8” 5/8” 5/8” 7/8” 7/8” 7/8”Suction line inch 1”5/8 1”5/8 1”5/8 1”5/8 1”5/8 1”5/8WeightOperating weight kg 490 560 560 740 850 870DimensionsLength mm 2.180 2.180 2.180 2.180 2.180 2.180Width mm 1.160 1.160 1.160 1.160 1.160 1.160Height mm 1.986 1.986 1.986 2.286 2.286 2.286
SysAqua 55-125 RE 55 65 75 90 105 125
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit118
Technical features 5 sizes Cooling capacity from 94,3 to 142,4 kW 3 versions:
STD (Standard) HT (High temperature) HPF (High pressure fans)
2 acoustic versions: - version (Basic Low Noise) S version (Super Low Noise)
One refrigerant circuit 2 scroll compressors (1 tandem) Microchannel coils E-Coating coil treatment as standard
Condensing unitSyScroll 85-135 Air RE
SyScroll 85-135 Air RE85 95 105 120 135
Min Max Min Max Min Max Min Max Min Max
Ambient Air
Air enteringtemperature(cooling)
- °C from +10 to +45S °C from -10 to +43HT-HPF °C from -12 to +47
Minimum capacity step % 50 43 50 44 50Power supply voltage1 V/ph/Hz 400/3/50 (Nominal)
1 Voltage 400V +/- 10%.
94-142 kW
Air cooled R410A
Scroll
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors box (standard) Compressors jackets (standard on Super Low Noise) Fan speed control (standard) Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Softstart Unit protection grilles
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
119
Technical performance
SyScroll 80-135 Air RE - (STD) 85 95 105 120 135Cooling capacity1 kW 94,3 105,0 116,4 130,5 142,4Power input2 kW 24,8 29,2 34,6 39,8 45,1Sound power level3 dB(A) 84 84 88 88 88Sound pressure level at 10 m4 dB(A) 52 52 56 56 56
Refrigerant connectionType To be brazedInlet diameter inch 1 5/8” 1 5/8” 2 1/8” 2 1/8” 2 1/8”Outlet diameter inch 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8”WeightShipping weight kg 625 697 765 817 840DimensionsLength mm 3.000 3.000 3.000 3.500 3.500Width mm 1.100 1.100 1.100 1.100 1.100Height mm 2.250 2.250 2.250 2.250 2.250
SyScroll 80-135 Air RE - (S) 85 95 105 120 135Cooling capacity1 kW 90,2 99,8 112,4 125,2 135,7Power input2 kW 26,3 31,3 36,7 42,5 48,4Sound power level3 dB(A) 82 82 85 85 85Sound pressure level at 10 m4 dB(A) 50 50 53 53 53
Physical features
SyScroll 80-135 Air RE
1 Data refers to 7°C evaporating temperature and 35°C condenser air temperature.2 Input power (only compressors).3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit120
Condensing unitAQVC 85-140
AQVC 85-140 85 95 105 115 125 140Evaporating limit °C from +1 to +15
Air temperatureBLN °C from 0 to +48ELN °C from -18 to +45HT °C from 0 to +50
Power supply V/Ph/Hz 400/3/50 (Nominal)
Technical features 6 sizes Cooling capacity from 92,1 to 151 kW 4 versions:
STD (Standard) HSE (High Seasonal Efficiency) HT (High Temperature) HPF (High Pressure Fans) 2 acoustic versions:
BLN (Basic Low Noise) ELN (Extra Low Noise)
Two refrigerant circuits 4 Scroll compressors (tandem) E-Coating coil treatment as standard
92-151 kW
Air cooled R410A
Scroll
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box as standard Compressors jackets Fan speed control Overload protection for compressors Power factor corrector capacitors Sequence phases control as standard Sofstart Unit protection grilles
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
121
Technical performance
AQVC STD/HSE/HPF 85-140 BLN 85 95 105 115 125 140Cooling capacity1 kW 92,1 103,2 113,2 121,8 134,7 151,0Power input1 kW 25,3 29,3 32,0 34,9 38,3 43,4Sound power level2 dB(A) 85 85 85 85 89 89Sound pressure level at 10 m3 dB(A) 53 53 53 53 57 57
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature, according EN14511 standard. 2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.4 Input power (only compressors).
CondenserConnection type To be brazedInlet diameter inch ⅝” ⅝” ⅝” ⅝” ⅞” ⅞”Outlet diameter inch 1⅜” 1⅜” 1⅜” 1⅜” 1⅜” 1⅜”WeightShipping weight BLN / - kg 971 983 1.013 1.043 1.066 1.142Shipping weight ELN kg 1.001 1.013 1.043 1.073 1.096 1.172DimensionsLength mm 2.555 2.555 2.555 2.555 3.155 3.155Width mm 1.095 1.095 1.095 1.095 1.095 1.095Height mm 2.185 2.185 2.185 2.185 2.185 2.185
AQVC STD/HSE 85-140 ELN 85 95 105 115 125 140Cooling capacity1 kW 89 99,4 108,7 116,6 131,6 147,2Power input1 kW 26,8 31,3 34,3 37,5 39,8 45,2Sound power level2 dB(A) 82 82 82 82 86 86Sound pressure level at 10 m3 dB(A) 50 50 50 50 54 54
AQVC HT 85-140 85 95 105 115 125 140Cooling capacity1 kW 95 106,8 117,7 127 137,2 153,8Power input4 kW 23,9 27,4 29,8 32,3 37,1 42,1Sound power level2 dB(A) 95 95 95 95 95 95Sound pressure level at 10 m3 dB(A) 63 63 63 63 63 63
Physical features
AQVC 85-140 85 95 105 115 125 140
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit122
Condensing unitSyScroll 140-360 Air EVO RE
Technical features 9 sizes Cooling capacity from 165 to 394,5 kW 4 versions:
STD (Standard) EC (Inverter Fans) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
Two refrigerant circuits 4 Scroll compressors E-Coating coil treatment as standard
SyScroll 140-360 Air EVO REEvaporating temperature °C from +3 to +15
Ambient
- °C from +5 to +48L °C from +0 to +46S °C from -14 to +44EC-HT °C from -18 to +50
Power supply V/Ph/Hz 400/3/50 (Nominal)
165-395 kW
Air cooled R410A
Scroll
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box as standard Compressors jackets (standard as Super Low Noise) Fan speed control standard Overload protection for compressors Power factor corrector capacitors Sequence phases control as standard Softstarter Unit protection grilles
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
123
Technical performance
SyScroll 140-360 Air EVO RE 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 165,0 193,4 216,3 250,3 288,4 312,7 337,2 361,2 394,5Input power2 kW 40,6 50,4 54,1 66,1 74,2 81,4 87,5 91,1 103,4Sound power level3 dB(A) 90 90 92 92 93 93 94 95 95Sound pressure level at 10 m4 dB(A) 58 58 60 60 61 61 62 63 63
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature.2 Input power (only compressors).3 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
SyScroll 140-360 Air EVO RE L 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 165,0 193,4 216,3 250,3 288,4 312,7 337,2 361,2 394,5Input power2 kW 42,5 52,8 56,2 69,3 77,6 85,3 91,9 95,3 108,6Sound power level3 dB(A) 85 85 87 87 88 88 89 90 90Sound pressure level at 10 m4 dB(A) 53 53 55 55 56 56 57 58 58
SyScroll 140-360 Air EVO RE S 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 166,6 195,6 218,2 252,8 291,2 315,9 340,5 364,4 398,4Input power2 kW 45,7 56,7 60,0 75,6 84,2 93,0 100,4 103,5 118,6Sound power level3 dB(A) 79 79 82 82 83 83 85 86 86Sound pressure level at 10 m4 dB(A) 47 47 50 50 51 51 53 54 54
SyScroll 140-360 Air EVO RE HT 140 170 200 230 260 280 300 330 360Nominal cooling capacity1 kW 166,6 195,6 218,2 252,8 291,2 315,9 340,5 364,4 398,4Input power2 kW 40,1 49,8 53,6 65,2 73,3 80,2 86,3 89,9 101,9Sound power level3 dB(A) 92 92 94 94 96 96 97 98 98Sound pressure level at 10 m4 dB(A) 60 60 62 62 64 64 65 66 66
Physical features
Water Connections (Evaporator)Type To be brazed
Refrigerant In connections inch 1 5/8” 1 5/8” 1 5/8” - 2 1/8”
1 5/8” - 2 1/8”
1 5/8” - 2 1/8”
1 5/8” - 2 1/8” 2 1/8” 2 1/8” 2 1/8”
Refrigerant Out connections inch 7/8” 7/8” 7/8” - 1 1/8”
7/8” - 1 1/8”
7/8” - 1 1/8”
7/8” - 1 1/8” 1 1/8” 1 1/8” 1 1/8”
WeightShipping weight kg 1.107 1.150 1.598 1.695 1.875 1.875 2.364 2.433 2.445DimensionsLength mm 4.000 4.000 3.500 3.500 3.500 3.500 4.550 4.550 4.550Width mm 1.100 1.100 2.150 2.150 2.150 2.150 2.150 2.150 2.150Height mm 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600 2.600
SyScroll 140-360 Air EVO RE 140 170 200 230 260 280 300 330 360
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit124
VLC 604-804 604 704 804Evaporating temperature °C from +3 to +15
Air temperatureBLN °C from -5 to +471 from -5 to +471 from 0 to +461
LN/ELN °C from -5 to +451 from -5 to +451 from 0 to +441
HT °C from -18 to +491 from -18 to +491 from -18 to +481
Power supply V/Ph/Hz 400/3/50 (Nominal)
VLC 904-1204 904 1004 1104 1204Evaporating temperature °C from +3 to +15
Air temperatureBLN °C from 0 to +461 from 0 to +461 from 0 to +451 from 0 to +451
LN/ELN °C from 0 to +451 from 0 to +441 from 0 to +421 from 0 to +421
HT °C from -18 to +491 from -18 to +481 from -18 to +471 from -18 to +471
Power supply V/Ph/Hz 400/3/50 (Nominal)
1 At high pressure 40,5 bar.
Condensing unitVLC 604-1204
Technical features 7 sizes Cooling capacity from 174 to 347 kW 4 versions:
STD (Standard) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions: BLN (Basic Low Noise) LN (Low Noise) ELN (Extra Low Noise)
Two refrigerant circuits 4 scroll compressors (tandem) E-Coating coil treatment as standard
174-347 kW
Air cooled R410A
Scroll
Accessories and options Automatic circuit breaker BMS interface Compressors acoustic box (standard) Compressors jackets (standard on ELN) Fan speed control (-18°C) Overload protection for compressors Power factor corrector capacitors Sequence phases control (standard) Sofstart Unit protection grilles
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
125
VLC STD/HPF 604-1204 BLN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 174,0 199,0 224,0 258,0 283,0 315,0 347,0Power input1 kW 52,5 63,0 69,0 79,0 83,0 98,0 112,0Sound power level2 dB(A) 93 93 93 94 94 95 95Sound pressure level at 10 m3 dB(A) 61 61 61 62 62 63 63
Technical performance
VLC STD 604-1204 LN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 169,0 194,0 218,0 251,0 272,5 301,0 330,0Power input1 kW 55,0 66,0 73,0 83,0 88,0 104,0 121,0Sound power level2 dB(A) 87 87 87 88 88 89 89Sound pressure level at 10 m3 dB(A) 55 55 55 56 56 57 57
VLC STD 604-1204 ELN 604 704 804 904 1004 1104 1204Cooling capacity1 kW 164,5 188,5 211,0 244,0 264,5 292,0 319,0Power input1 kW 57,0 69,0 76,5 86,5 91,5 108,0 127,0Sound power level2 dB(A) 83 83 83 84 84 85 85Sound pressure level at 10 m3 dB(A) 51 51 51 52 52 53 53
VLC HT 604-1204 604 704 804 904 1004 1104 1204Cooling capacity1 kW 176,0 201,0 226,5 261,0 286,5 318,0 353,0Power input1 kW 51,5 62,0 68,0 77,5 81,0 95,0 109,0Sound power level2 dB(A) 99 99 99 100 100 100 100Sound pressure level at 10 m3 dB(A) 67 67 67 68 68 68 68
Physical features
Refrigerant connectionInlet diameter inch ⅞” ⅞” ⅞” 1⅛” 1⅛” 1⅛” 1⅛”Outlet diameter inch 1⅝” 1⅝” 1⅝” 2⅛” 2⅛” 2⅛” 2⅛”WeightShipping weight BLN / LN kg 1.300 1.490 1.615 1.700 1.825 1.910 1.920Shipping weight ELN kg 1.335 1.525 1.650 1.735 1.865 1.950 1.960Shipping weight - kg 1.330 1.520 1.645 1.740 1.865 1.950 1960DimensionsLength mm 3.300 4.300 4.300 4.300 4.300 4.300 4.300Width mm 1.100 1.100 1.100 1.100 1.100 1.100 1.100Height mm 2.300 2.300 2.300 2.300 2.300 2.300 2.300
VLC 604-1204 604 704 804 904 1004 1104 1204
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature.2 Sound levels are at fully loaded conditions. Sound power level values refers to ISO 3744 standard. 3 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit126
SyScroll 240-360 Air RE 240 270 290 320 360
Ambient temp.
Air temp. cooling
- °C from +10 to +45L °C from +7 to +43S °C from -14 to +43HT-HPF °C from -18 to +47
Minimum capacity step % 31 33 30 27 23Power supply voltage1 V/Ph/Hz 400/3/50 (Nominal)
SyScroll 420-660 Air RE 420 470 540 590 660
Ambient temp.
Air temp. cooling
- °C from +10 to +45L °C from +7 to +43S °C from -14 to +43HT-HPF °C from -18 to +47
Minimum capacity step % 31 33 30 27 23Power supply voltage1 V/Ph/Hz 400/3/50 (Nominal)
1 Voltage 400V +/- 10%.
Condensing unitSyScroll 240-660 Air RE
Technical features 10 sizes Cooling capacity from 267,5 to 726,7 kW 3 versions:
STD (Standard) HT (High Temperature) HPF (High Pressure Fans)
3 acoustic versions: - (Basic Low Noise) L (Low Noise) S (Super Low Noise)
Two refrigerant circuits 3/4/5/6 Scroll compressors Microchannel coils E-Coating coil treatment as standard
267-727 kW
Air cooled R410A
Scroll
Accessories and options Automatic circuit breaker BMS interface Coils treatments Compressors acoustic box (standard) Compressors jackets (standard) Overload protection for compressors Power factor corrector capacitors Pressostatic fan speed control (standard) Sequence phases control (standard) Softstart Unit protection grilles
Operating limits (to be confirmed with SysofAC - www.sysoftac.com)
Condensing unit |
COND
ENSI
NG U
NIT
127
SyScroll 240-360 Air RE - 240 270 290 320 360Nominal cooling capacity1 kW 267,5 303,1 330,7 349,9 403,2Input power2 kW 76,8 92,8 95,4 103,8 119,0Sound power level3 dB(A) 93 93 94 94 94Sound pressure level at 10 m4 dB(A) 61 61 62 62 62
Technical performance
SyScroll 240-360 Air RE L 240 270 290 320 360Nominal cooling capacity1 kW 256,7 288,7 316,7 333,9 385,4Input power2 kW 80,9 98,4 100,6 109,6 125,8Sound power level3 dB(A) 88 88 89 89 90Sound pressure level at 10 m4 dB(A) 56 56 57 57 58
SyScroll 240-360 Air RE S 240 270 290 320 360Nominal cooling capacity1 kW 236,4 262,0 262,0 304,4 352,6Input power2 kW 89,2 109,2 109,2 120,7 139,2Sound power level3 dB(A) 85 86 87 87 88Sound pressure level at 10 m4 dB(A) 53 54 55 55 56
Physical features
Refrigerant connection
Refrigerant In connections inch 1 5/8” - 2 1/8”
1 5/8” - 2 1/8”
1 5/8” - 2 1/8”
1 5/8” - 2 1/8” 2 1/8”
Refrigerant Out connections inch 7/8” - 1 1/8”
7/8” - 1 1/8”
7/8” - 1 3/8”
7/8” - 1 3/8”
1 1/8” - 1 3/8”
WeightShipping weight kg 1.670 1.671 1.790 1.802 2.185DimensionsLength mm 3.500 3.500 3.500 3.500 4.550Width mm 2.150 2.150 2.150 2.150 2.150Height mm 2.600 2.600 2.600 2.600 2.600
SyScroll 240-360 Air RE 240 270 290 320 360
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature.2 Input power (only compressors).3 Sound power levels in full load condition refer to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Condensing unit128
SyScroll 420-660 Air RE - 420 470 540 590 660Nominal cooling capacity1 kW 466,2 518,8 594,9 650,4 726,7Input power2 kW 138,4 148,6 170,6 182,7 204,9Sound power level3 dB(A) 95 95 96 96 97Sound pressure level at 10 m4 dB(A) 63 63 64 64 64
SyScroll 420-660 Air RE L 420 470 540 590 660Nominal cooling capacity1 kW 444,8 495,9 567,7 621,5 693,4Input power2 kW 146,1 157,0 180,1 193,1 216,4Sound power level3 dB(A) 91 91 91 92 92Sound pressure level at 10 m4 dB(A) 59 59 59 59 59
SyScroll 420-660 Air RE S 420 470 540 590 660Nominal cooling capacity1 kW 405,5 453,6 517,5 568,1 632,2Input power2 kW 161,0 173,5 198,4 213,1 238,3Sound power level3 dB(A) 88 89 89 90 90Sound pressure level at 10 m4 dB(A) 56 57 57 57 57
Refrigerant connection
Refrigerant In connections inch 2 1/8” 2 1/8” - 2 5/8”
2 1/8” - 2 5/8” 2 5/8” 2 5/8”
Refrigerant Out connections inch 1 3/8” 1 3/8” 1 3/8” 1 3/8” 1 3/8”
WeightShipping weight kg 2.296 2.747 2.860 3.237 3.333DimensionsLength mm 4.550 5.600 5.600 6.650 6.650Width mm 2.150 2.150 2.150 2.150 2.150Height mm 2.600 2.600 2.600 2.600 2.600
SyScroll 420-660 Air RE 420 470 540 590 660
Technical performance
Physical features
1 Data refers to 7°C leaving chilled water temperature and 35°C condenser air temperature.2 Input power (only compressors).3 sound power levels in full load condition refer to ISO 3744 standard.4 Sound pressure levels refer to ISO 3744 standard, parallelepiped shape.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
Condensing unit |
COND
ENSI
NG U
NIT
129
Keep it cool.With Systemair Air Conditioning system.
COND
ENSI
NG U
NIT
| Residential Heat Pump 130
Residential Heat Pump
Aquascop HT V2 5,4-15,6 kW R407C Cascade ScrollPage 132
Aquascop HT split 5,4-15,6 kW R407C Cascade ScrollPage 136
Residential Heat Pump |
RESI
DENT
IAL
HEAT
PUM
P
131
Product Range Capacity COP Flow Rate Acoustic Power
Size - outdoor unit (LxHxW) mm
Aqua
scop
HT
V2 Aquascop HT V2 12.6 6,3 kW (A7°C/W35°C) 4,12 1.030 l/h 67dB(A) 1.457 x 1.308 x 516
Aquascop HT V2 14.7 7,4 kW (A7°C/W35°C) 4,25 1.370 l/h 67dB(A) 1.457 x 1.308 x 516
AquascopHT V2 18.9 9,0 kW (A7°C/W35°C) 4,28 1.580 l/h 67dB(A) 1.457 x 1.308 x 516
Aqua
scop
HT
SPL
IT Aquascop HT SPLIT 12.6 6,3 kW (A7°C/W35°C) 4,12 1.030 l/h 65dB(A) 1.457 x 1.308 x 516
Aquascop HT SPLIT 14.7 7,4 kW (A7°C/W35°C) 4,25 1.370 l/h 65dB(A) 1.457 x 1.308 x 516
Aquascop HT SPLIT 18.9 9,0 kW (A7°C/W35°C) 4,28 1.580 l/h 65dB(A) 1.457 x 1.308 x 516
Selection guide High Temperature Residential Heat Pump
| Residential Heat Pump 132
Monobloc unit High temperature heat pumpAquascop HT V2
Technical features Ideal for renovations as well as for new construction Water outlet temperature up to 65°C without external backup Ideal for boiler replacement Constant operation at +65°C with -20°C outdoors Heating capacity from 5,4 to 15,6 kW Systemair patented “dual-stage” cascading compressors A single refrigerant fluid (preloaded up to 20 m) Electronic expansion valve and flow meter Low noise level Three-speed circulator pump Dual-zone management
Product Advantages Very high performance, COP up to 4,28 SCOP class A++ Very low noise level No refrigerant links to be made Information screen with eight lines of text in French with
diagnosis assistance New “antifreeze” evaporator, 2 hours without defrosting
(no 4-mm fins) Inverter fans Easy maintenance Possibility of installing several heat pumps in cascade
(upon request)
Main accessories and options 6 kW electric heater 140-litre buffer tank / mixing tank 300-litre domestic hot water tank kit
Operating limits
SYSTEMAIR
PATENTED[ ]
5,4-15,6 kW R407C
10
15
20
25
30
35
40
45
50
55
60
65
70
-15- 10 -5 05 10 15 20-20-25 25
Double étage - mini retour d'eau
Double étage - maxi départ d'eau
Mono étage - maxi départ d'eau
MONO ÉTAGE
Outside temperature °C
Double stage – water return min.
DOUBLE STAGE
SINGLE STAGE
Double stage – water starting max.
Single stage – water starting max.
Wat
er fl
ow s
etpo
int (
°C)
Decanting filter (sludge pot) Dual-zone kit for radiators and floor (without valve) Hydraulic connection kit with three-way valve Hydraulic connection kit without three-way valve Plate exchanger & circulator pump kit for domestic hot water,
top outlet (sensor supplied for installation) Plate exchanger & circulator pump kit for domestic hot water,
bottom outlet (sensor supplied and installed) Programmable and communicating ambient thermostat Remote wireless ambient sensor Shock-absorbing support feet Shut-off valve with pressure tap Three-phase starting intensity limiter (STD on single-phase) Three-way valve alone for domestic hot water management
or boiler backup Water filter
Cascade scroll
CE STANDARD
LO WTEMPERATURE
HEATER
LOW-TEMPERATURE
RADIATOR
BOILER REPLACEMENT
BOILER BACKUP
BI-ZONE DOMESTIC HOT WATER
WATER PROGRAMME
PATENTED
R407C FLUID OUTDOOR OPERATING
LIMITS IN HEATING MODE
HIGH TEMPERATURE
UP TO 65°C
PRODUCT DEVELOPED AND MANUFACTURED
IN FRANCE
°C-
Residential Heat Pump |
RESI
DENT
IAL
HEAT
PUM
P
133
Physical Data
Electrical Data
AquaScop HT V2 MODELS 12-6 14-7 18-9RefrigerantType R407CHydraulic connectionsWater inlet gas 1" FemaleWater outlet gas 1" FemaleWater flowNominal l/h 1.030 1.370 1.580Minimum l/h 890 1.170 1.340Maximum l/h 1.160 1.530 1.775FansFans (x2) 206 W - 700 rpm - 6000 m3/hSound levelsSound power levels dB(A) 67 67 67
AquaScop HT V2 MODELS 12-6 14-7 18-9SUPPLY VOLTAGE 400 V/3 Ph/50 HzStarting current with limiter A < 60Max. current A 15 16 18SUPPLY VOLTAGE 230 V/ 1 Ph/50 HzStarting current with limiter A < 45Max. current A 28 32 -
Note: Seasonal space heating energy efficiency class according to the Delegated Regulation No. 811/2013 of the European Commission.
Water conditionModels AquaScop HT V2
12-6 14-7 18-9
55°C
35°C
A+A++
A+A++
A+A++
| Residential Heat Pump 134
Performance Data
AquaScop HT V2 models 12-6 14-7 18-9
Outdoor air condition+7 °C / +6 °C WB
Water condition 30/35 °CHeating capacity single-compressor kW 6,30 7,40 8,98Power input kW 1,53 1,74 2,10COP 4,12 4,25 4,28Water condition 45 °CHeating capacity single-compressor kW 5,86 7,93 9,46Power input kW 1,86 2,35 2,67COP 3,15 3,37 3,54Water condition 55 °CHeating capacity dual-compressor kW 5,36 7,22 8,75Power input kW 2,30 2,85 3,27COP with defrost 2,33 2,53 2,68
Outdoor air condition+2 °C / +1 °C WB
Water condition 35 °CHeating capacity dual-compressor kW 10,52 13,26 15,63Power input kW 2,99 3,82 4,39COP with defrost 3,52 3,47 3,56
Outdoor air condition-7 °C / -8 °C WB
Water condition 35 °CHeating capacity dual-compressor kW 8,21 10,89 12,46Power input kW 2,78 3,64 4,11COP with defrost 2,95 2,99 3,03Water condition 55 °CHeating capacity dual-compressor kW 8,57 10,92 12,69Power input kW 3,74 4,63 5,29COP with defrost 2,29 2,36 2,40Water condition 65 °CHeating capacity dual-compressor kW 8,49 10,90 12,25Power input kW 4,45 5,30 5,92COP with defrost 1,91 2,06 2,07
Outdoor air condition-15 °C
Water condition 35 °CHeating capacity dual-compressor kW 7,95 10,44 11,94Power input kW 2,78 3,58 4,04COP with defrost 2,86 2,92 2,96
Outdoor air condition-20 °C
Water condition 55 °CHeating capacity dual-compressor kW 8,03 10,32 11,28Power input kW 3,95 4,73 5,22COP with defrost 2,03 2,18 2,16
AquaScop HT V2 models 12-6 14-7 18-9Nominal water flow m3/h 1.030 1.370 1.580Available hydraulic pressure - High speed kPa 55 48 55Operating limits (outdoor temperature) °C -20Outlet water temperature Min. / Max. °C +25/+65
WB : Wet bulb.
Residential Heat Pump |
RESI
DENT
IAL
HEAT
PUM
P
135
Bouygues ChallengerGuyancourt, France
Site: BuildingProduct: Water source heat pump SYSHRWApplication: Air conditioning
| Residential Heat Pump 136
Split unitHigh temperature heat pumpAquascop HT split
Technical features Ideal for renovations as well as for new construction Water outlet temperature up to 65°C without external backup Ideal for boiler replacement Constant operation at +65°C with -20°C outdoors Heating capacity from 5,4 to 15,6 kW Systemair patented “dual-stage” cascading compressors A single refrigerant fluid (preloaded up to 20 m) Electronic expansion valve and flow meter
Low noise level Three-speed circulator pump Dual-zone management
Product Advantages Very high performance, COP up to 4,28 SCOP class A++ Aesthetics and aluminium finish Very low noise level
Compact wall unit (700x400x260) Weight of 30 kg only for the indoor unit, can be installed by
one person working alone Fluid connections on the bottom surface Cover removable by a quarter turn for immediate access
Information screen with eight lines of text in French with diagnosis assistance
New “antifreeze” evaporator, 2 hours without defrosting (no 4-mm fins) Inverter fans No risk of frost for the water, and no need to add glycol
to the installation Easy maintenance Possibility of installing several heat pumps in cascade (upon
request)
SYSTEMAIR
PATENTED[ ]
5,4-15,6 kW R407C
Operating limits
10
15
20
25
30
35
40
45
50
55
60
65
70
-15- 10 -5 05 10 15 20-20-25 25
Double étage - mini retour d'eau
Double étage - maxi départ d'eau
Mono étage - maxi départ d'eau
MONO ÉTAGE
Outside temperature °C
Double stage – water return min.
DOUBLE STAGE
SINGLE STAGE
Double stage – water starting max.
Single stage – water starting max.
Wat
er fl
ow s
etpo
int (
°C)
Main accessories and options 6 kW electric heater 140-litre buffer tank / mixing tank 300-litre domestic hot water tank kit Decanting filter (sludge pot) Dual-zone kit for radiators and floor (without valve) Hydraulic connection kit with three-way valve
Hydraulic connection kit without three-way valve Plate exchanger & circulator pump kit for domestic hot water,
top outlet (sensor supplied for installation) Plate exchanger & circulator pump kit for domestic hot water,
bottom outlet (sensor supplied and installed) Programmable and communicating ambient thermostat Remote wireless ambient sensor Shock-absorbing support feet Shut-off valve with pressure tap Three-phase starting intensity limiter (STD on single-phase) Three-way valve alone for domestic hot water management
or boiler backup Water filter
Cascade scroll
CE STANDARD
LO WTEMPERATURE
HEATER
LOW-TEMPERATURE
RADIATOR
BOILER REPLACEMENT
BOILER BACKUP
BI-ZONE DOMESTIC HOT WATER
WATER PROGRAMME
PATENTED
R407C FLUID OUTDOOR OPERATING
LIMITS IN HEATING MODE
HIGH TEMPERATURE
UP TO 65°C
PRODUCT DEVELOPED AND MANUFACTURED
IN FRANCE
°C-
Residential Heat Pump |
RESI
DENT
IAL
HEAT
PUM
P
137
* Depending on system configuration, the indoor unit can be separately powered or powered from the outdoor unit (one upstream general protection only).
Electrical Data
AquaScop HT Split models 12-6 14-7 18-9RefrigerantType R407CRefrigerant connectionsGas refrigerant piping (0 to 25 meters) inch 5/8Liquid refrigerant piping (0 to 25 meters) inch 3/8Gas refrigerant pipings (0 to 45 meters) inch 3/4Liquid refrigerant piping (0 to 45 meters) inch 1/2FansFans (x2) 206 W - 700 rpm - 6000 m3/hSound levelsOutdoor unit sound power levels dB(A) 65 65 65
Physical Data
AquaScop HT Split models 12-6* 14-7* 18-9Refrigerant connectionsGas line inch 5/8Liquid line inch 3/8Hydraulic connectionsInlet water gas 1" female / Rotating nutOutlet water gas 1" female / Rotating nutWater flowNominal l/h 1.030 1.370 1.580Minimum l/h 890 1.170 1.340Maximum l/h 1.160 1.530 1.775Sound levelsIndoor unit sound power levels dB(A) 41 41 41
* Indoor unit is common for outdoor units 12-6 and 14-7.
AquaScop HT Split models 12-6 14-7 18-9POWER SUPPLY 400 V/3 Ph/50 HzStarting current with limiter A < 60Max. current - Outdoor unit only A 12,2 13,2 15,2Max. current. - Outdoor unit + Indoor unit + Accessories* A 15,5 16,5 18,5POWER SUPPLY 230 V/ 1 Ph/50 HzStarting current with limiter A < 45Max. current - Outdoor unit only A 25,7 27,2 -Max. current - Outdoor unit + Indoor unit + Accessories* A 29 30,5 -
AquaScop HT Split models 12-6 14-7 18-9POWER SUPPLY 230 V/ 1 Ph/50 HzMax. current - Indoor unit only A 1,8 1,8 1,8Max. current - Indoor unit + Accessories A 3,3 3,3 3,3
Note: Seasonal space heating energy efficiency class according to the Delegated Regulation No. 811/2013 of the European Commission.
Water conditionModels AquaScop HT Split
12-6 14-7 18-9
55°C
35°C
A+A++
A+A++
A+A++
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
| Residential Heat Pump 138
Performance Data
AquaScop HT Split models 12-6 14-7 18-9
Outdoor air condition+7 °C / +6 °C WB
Water condition 30/35 °CHeating capacity single-compressor kW 6,30 7,40 8,98Power input kW 1,53 1,74 2,10COP 4,12 4,25 4,28Water condition 45 °CHeating capacity single-compressor kW 5,74 7,77 9,27Power input kW 1,86 2,35 2,67COP 3,09 3,31 3,47Water condition 55 °CHeating capacity dual-compressor kW 5,25 7,08 8,58Power input kW 2,30 2,85 3,27COP with defrost 2,28 2,48 2,62
Outdoor air condition+2 °C / +1 °C WB
Water condition 35 °CHeating capacity dual-compressor kW 10,31 13,00 15,32Power input kW 2,99 3,82 4,39COP with defrost 3,45 3,40 3,49
Outdoor air condition-7 °C / -8 °C WB
Water condition 35 °CHeating capacity dual-compressor kW 8,21 10,89 12,46Power input kW 2,78 3,59 4,05COP with defrost 2,95 3,03 3,08Water condition 55 °CHeating capacity dual-compressor kW 8,40 10,71 12,44Power input kW 3,74 4,63 5,29COP with defrost 2,25 2,31 2,35Water condition 65 °CHeating capacity dual-compressor kW 8,33 10,69 12,01Power input kW 4,45 5,30 5,92COP with defrost 1,87 2,02 2,03
Outdoor air condition-15 °C
Water condition 35 °CHeating capacity dual-compressor kW 7,79 10,24 11,71Power input kW 2,78 3,58 4,04COP with defrost 2,80 2,86 2,90
Outdoor air condition-20 °C
Water condition 55 °CHeating capacity dual-compressor kW 7,87 10,12 11,06Power input kW 3,95 4,73 5,22COP with defrost 1,99 2,14 2,12
WB : Wet bulb.
AquaScop HT Split models 12-6 14-7 18-9Nominal water flow m3/h 1.030 1.370 1.580Available hydraulic pressure - High speed kPa 55 48 55Operating limits (outdoor temperature) °C -20Outlet water temperature Min. / Max. °C +25/+65
Residential Heat Pump |
RESI
DENT
IAL
HEAT
PUM
P
139
Tunnel EuralpinSaint Martin la Porte, France
Site: Tunnel excavationProduct: Air cooled chiller Syscroll 590 AIR COApplication: Water cooled system for excavation
Norengros buildingNorway
Site: BuildingProduct: Air cooled chiller SysAqua 190 Application: Air conditioning
| Water Terminals140
Water Terminals
Hawair 1,0-3,9 kW 1,4-4,1 kWPage 156
SysQuare 1,4-9,6 kW 1,1-14,0 kW Motor EC Pages 152 to 155
DUCTYS 0,8-6,7 kW 0,7-7,1 kW Motor ECPage 158
Selection guide water terminals units Fan Coil units
Product Family Cooling Capacity * Acoustic Flow rate* Pressure FanSize (with cabinet
- without feet) (LxWxH)
SysC
oil C
omfo
rt
SCC10 2,1 kW NR 30 at MS 108-417 m³/h 0-30 Pa AC/EC 766 x 477 x 225
SCC20 2,4 kW NR 34 at MS 98-413 m³/h 0-30 Pa AC/EC 766 x 477 x 225
SCC30 3,1 kW NR 36 at MS 185-570m³/h 0-30 Pa AC/EC 951 x 477 x 225
SCC40 4,2 kW NR 32 at MS 170-678 m³/h 0-30 Pa AC/EC 1136 x 477 x 225
SCC50 5,0 kW NR 38 at MS 203-816 m³/h 0-40 Pa AC/EC 1321 x 477 x 225
SCC60 5,2 kW NR 41 at MS 245-912 m³/h 0-40 Pa AC/EC 1506 x 477 x 225
SCC70 6,9 kW NR 37 at MS 417-1.028 m³/h 0-40 Pa AC/EC 1321 x 477 x 225
SCC80 8,8 kW NR 44 at MS 685-1.398 m³/h 0-40 Pa AC/EC 1508 x 578 x 225
SysCoil Comfort 0,5-9,6 kW 0,6-13,6 kW Motor ECPages 144 to 151
* EC fan / 2-pipe version
ErP2018
ErP2018 NEW
NEW ErP2018
ErP2018
VH 4,1-21,9 kW 4,7-29,6 kW Motor EC Pages 160 to 163
New
ErP2018
All Systemair terminal units are ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281.
Available from September 2018
Water Terminals |
WAT
ER TE
RMIN
ALS
141
Water cassettes
Product Family Cooling Capacity * Acoustic Flow rate * Pressure FanSize
(casing + Irys diffuser) (LxWxH)
SysQ
uare
SQ20 2,4 kW NR 27 at MS 360-659 m³/h 0 Pa AC/EC 595 x 595 x 341
SQ30 4,0 kW NR 30 at MS 320-734 m³/h 0 Pa AC/EC 595 x 595 x 341
SQ40 4,7 kW NR 34 at MS 486-900 m³/h 0 Pa AC/EC 595 x 595 x 341
SQ50 6,1 kW NR 26 at MS 529-979 m³/h 0 Pa AC/EC 849 x 849 x 352
SQ60 7,2 kW NR 32 at MS 500-1.159 m³/h 0 Pa AC/EC 849 x 849 x 352
SQ70 9,6 kW NR 38 at MS 601-1.598 m³/h 0 Pa AC/EC 849 x 849 x 352
Selection guide water terminals units
Highwall units
Product Family Cooling Capacity Acoustic Flow rate Pressure Fan Size (LxWxH)
Haw
air
HAW007-A 1,7 kW NR 36 at MS 282-360 m³/h 0 Pa AC 845 x 275 x 180
HAW009-A 2,4 kW NR 39 at MS 367-551 m³/h 0 Pa AC 845 x 275 x 180
HAW0018-A 3,5 kW NR 43 at MS 532-680 m³/h 0 Pa AC 940 x 298 x 200
HAW0022-A 3,9 kW NR 46 at MS 617-850 m³/h 0 Pa AC 940 x 298 x 200
Ducted units
Product Family Cooling Capacity * Acoustic * Flow rate * Pressure FanSize - configuration : rectangular return and
discharge (LxWxH)
DUCT
YS
DT10 2,0 kW NR 30 at MS 127-464 m³/h 0-100 Pa EC 631 x 633 x 223
DT15 2,1 kW NR 32 at MS 255-491 m³/h 0-100 Pa EC 631 x 733 x 223
DT20 2,7 kW NR 35 at MS 360-599 m³/h 0-100 Pa EC 631 x 833 x 223
DT25 3,2 kW NR 34 at MS 448-642 m³/h 0-100 Pa EC 631 x 933 x 223
DT40 6,7 kW NR 34 at MS 347-1034 m³/h 0-100 Pa EC 653 x 1.233 x 223
Product Family Cooling Capacity * Acoustic * Flow rate * Pressure FanSize - configuration : rectangular return and
discharge (LxWxH)
VH
VH07 5,6 kW NR 34 at MS 703-1126 m³/h 0-150 Pa AC/EC 698 x 1.200 x 250
VH15 13,3 kW NR 40 at MS 990-2845 m³/h 0-150 Pa AC/EC 798 x 1.380 x 375
VH18 13,9 kW NR 40 at MS 990-2845 m³/h 0-150 Pa AC/EC 798 x 1.380 x 375
VH21 17,0 kW NR 40 at MS 990-2845 m³/h 0-150 Pa AC/EC 798 x 1.380 x 375
VH24 19,0 kW NR 44 at MS 2023-2845 m³/h 0-150 Pa AC/EC 798 x 1.500 x 450
VH27 21,9 kW NR 44 at MS 2023-2845 m³/h 0-150 Pa AC/EC 798 x 1.500 x 450
* EC fan / 2-pipe version
* 2-pipe version
* AC fan / 2-pipe version
| Water Terminals142
Wide range of ready-to-install control systems.
Fin coils for efficient and hygienic solution.
EC fan available.
A Large Rangeof EFFICIENT, RELIABLE and FLEXIBLE units!
Many efficient and intuitive ways to control your unit(s).
A wide range of accessories and options.
Robust units - Monobloc drain pan.
Water Terminals |
WAT
ER TE
RMIN
ALS
143
A large range of terminal units dedicated to energy saving and comfort
Low consumption solution with: High efficiency fan motor
High level of energy performance with mainly Energy class A or B
Same thermal performance as with AC fan motor
Silence Optimized fan speed staging for new low noise versions Reinforced acoustical insulation Profiled air diffuser
Factory facilities dedicated to flexibility and quality
Many factory-mounted options or accessories: Control Valve Air diffuser Condensate drain pump
Products fully customized to satisfy your requirements: Choice of service side for hydraulic and electric connection Version with or without cabinet On-board control
100% units are tested electrically and acoustically.
All Terminals Unitsare according to Eurovent standard.
ErP2018
All Systemair terminal units are ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281.
| Water Terminals144
Fan coil unitsCooling and heatingSysCoil Comfort
Technical features Cooling Capacity from 0,7 to 8,1 kW Heating Capacity from 0,7 to 10,3 kW 8 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configurations Universal installation units (vertical or ceiling exposed)
with cabinet
Product Advantages Ease of installation Harmonious and aesthetic RAL 9003 painted cabinet design Streamlined design and elaborate finish enabling
harmonious integration 5-speed AC fan motor(s) Very low operating acoustical levels Airflow rate between 95 and 1.397 m³/h
Main accessories and options 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump Electrical heater Feet kit + grid between feet Front air intake with removable grid Front/Back/Floor air intake with manual damper Fuse holder G3 filter Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/MRC/BRC remote controls for SysLogic*
0,7-8,1 kW 0,7-10,3 kW
HOTELS OFFICES
WRC remote control
Operating limits
ErP20182018
SysCoil ComfortEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
NEW versions with improved acoustic performances!
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Available from September 2018
Water Terminals |
WAT
ER TE
RMIN
ALS
145
Technical features
With G2 filter.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 The sound pressure levels are based on (NR) characteristics of a room having volume of 100 m3 with reverberation of 0,5 seconds.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysCoil Comfort
(with cabinet)
SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80
S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 0,72/1,00/1,45 0,74/1,24/1,68 1,00/1,98/2,5 1,2/2,4/3,18 1,72/3,16/4,63 2,71/4,55/5,82 3,41/6,14/7,27 4,63/6,08/8,13
Sensible capacity kW 0,53/0,77/1,16 0,55/0,93/1,3 0,82/1,52/1,9 0,82/1,77/2,34 1,24/2,23/3,27 1,9/3,3/4,47 2,37/4,44/5,57 3,41/4,57/6,29
Water flow l/h 124/172/250 127/213/289 172/341/430 206/413/547 296/544/798 466/784/1003 587/1058/1252 798/1048/1400
Water pressure drop kPa 10,7/19,5/39,2 1,8/3,9/6,3 3,2/10,2/15,4 5,4/17,1/28 7,5/22,8/46,9 13,9/37,4/60,2 4,8/15,4/21,5 11,9/19,3/32,5
Heating 2
Heating capacity kW 0,7/1,1/1,54 0,72/1,17/1,66 1,05/1,96/2,62 1,17/2,28/3,1 1,72/3,3/4,54 1,91/3,22/4,3 3,49/6,22/7,36 4,95/6,8/9,9
Water flow l/h 121/189/265 124/202/286 181/338/451 202/393/534 296/568/782 329/555/741 601/1071/1268 853/1171/1705
Water pressure drop kPa 7,1/15,2/27,9 1,8/3,6/6,2 3,5/10/16,7 5,2/15,7/26,8 5,6/18,8/34,5 11,7/31,2/54,3 5/15,8/22 13,4/23,5/46,7
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 0,66/0,92/1,3 0,63/1,12/1,56 0,96/1,9/2,4 1,13/2,25/3 1,65/3,03/4,34 2,6/4,39/5,61 3,34/5,92/6,93 4,5/5,92/8,01
Sensible capacity kW 0,48/0,7/1,03 0,47/0,84/1,2 0,79/1,46/1,83 0,76/1,66/2,21 1,19/2,15/3,07 1,82/3,18/4,28 2,32/4,27/5,23 3,3/4,44/6,19
Water flow l/h 114/159/225 109/192/268 165/327/414 194/388/517 284/522/748 449/756/967 575/1019/1193 775/1020/1380
Water pressure drop kPa 8,3/15,2/29,0 1,5/3,4/5,6 3/9,5/14,4 7,2/22,3/36,8 4,2/12,8/25,1 10,3/27,7/44,5 5,9/17,9/24,4 19,3/31,1/53,6
Heating 3
Heating capacity kW 0,65/0,99/1,35 0,75/1,15/1,44 1,34/1,91/2,24 1,32/2,22/2,79 2,03/3,21/4,06 2,01/3,08/3,87 3,7/4,97/5,86 5,66/8,06/10,30
Water flow l/h 56/85/117 65/99/124 116/165/193 114/191/241 175/276/349 173/265/333 318/428/505 487/695/888
Water pressure drop kPa 1,2/2,0/3,1 <1/1,5/2,3 3/5,2/6,6 5,8/14/21,1 5,8/12,6/19,2 7,2/14,3/21,1 36,1/60,1/80,3 18,7/35,1/54,8
Sound LevelsGlobal sound power level dB(A) 33/40/49 31/43/50 30/45/52 30/44/51 34/46/56 38/51/58 43/56/61 50/55/64
Global sound pressure level 4 dB(A) 23/33/43 27/37/43 21/34/42 23/35/42 20/38/47 23/43/52 33/46/51 40/43/55
NR 4 dB(A) 19/30/38 22/33/39 16/29/37 19/30/38 16/34/41 19/40/48 28/41/46 38/41/51
Fan(s)
Number 1 1 1 2 2 2 2 3
Air flow - 2 pipes m³/h 111/190/283 105/179/265 138/274/390 173/357/499 263/486/716 350/640/933 480/893/1064 660/936/1397
Air flow - 4 pipes m³/h 95/168/253 89/161/241 132/263/369 162/335/467 242/466/671 334/614/885 470/859/1012 634/905/1370
Filter G2
Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz
Motor Absorbed Power - 2 pipes W 13/24/36 10/18/29 16/37/45 15/37/56 28/55/72 37/75/105 53/100/147 90/112/188
Motor Absorbed Power - 4 pipes W 13/24/36 10/18/28 16/37/44 15/37/55 28/54/70 37/74/104 53/99/145 90/112/188
Electrical heater (max.) W 500 500 500/1000 1250/2500 1250/2500 1250/2500 1000/2000 1500/3000
Water ConnectionsType Female gas threaded
2 pipes or 4 pipes “cooling” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’
4 pipes “heating” inch 1/2’’
Weight and DimensionsWeight kg 19 19 22,5 29 32 37 37 52
Dimensions (LxWxH) without feet mm 766x477x225 766x477x225 951x477x225 1136x477x225 1321x477x225 1506x477x225 1321x577x225 1508x578x225
| Water Terminals146
Fan coil unitsCooling and heatingSysCoil Comfort EC
Technical features Cooling Capacity from 0,5 to 9,6 kW Heating Capacity from 0,6 to 13,6 kW 8 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configurations Universal installation units (vertical or ceiling exposed)
with cabinet
Product Advantages Ease of installation Harmonious and aesthetic RAL9003 painted cabinet design Streamlined design and elaborate finish enabling harmonious
integration Low energy consumption EC fan(s) Very low operating acoustical levels Airflow rate between 91 and 1.548 m³/h
Main accessories and options 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump ECoSpeed3 board for EC fan(s)* Electrical heater Feet kit + grid between feet Front air intake with removable grid Front/Back/Floor air intake with manual damper Fuse holder G3 filter Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/MRC/BRC remote controls for SysLogic*
HOTELS OFFICES
0,5-9,6 kW EC Motor
0,6-13,6 kW
WRC remote control
Operating limits
ErP20182018
SysCoil Comfort ECEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
NEW versions with improved acoustic performances!
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Available from September 2018
Water Terminals |
WAT
ER TE
RMIN
ALS
147
Technical features
With G2 filter.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 The sound pressure levels are based on (NR) characteristics of a room having volume of 100 m3 with reverberation of 0,5 seconds.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysCoil Comfort EC
(with cabinet)
SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80
S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 0,62/1,22/2,07 0,64/1,38/2,36 0,86/2,06/3,09 1,34/2,94/4,19 1,34/3,97/4,98 1,98/4,45/5,24 2,69/5,85/6,9 5,1/6,45/8,8
Sensible capacity kW 0,51/1,05/1,85 0,49/1,12/1,91 0,64/1,61/2,4 0,95/2,1/3,0 1,05/3/3,7 1,35/3,51/4,02 2,01/4,31/5,22 3,69/4,75/6,61
Water flow l/h 107/210/356 110/237/406 148/354/532 230/506/722 231/685/858 341/767/903 463/1008/1189 879/1111/1516
Water pressure drop kPa 8,2/28,2/76,9 1,5/4,6/11 5,0/20,5/42,1 6,4/24,4/46,3 4,9/35,1/53,9 7,7/35,8/49,1 3/14/19,4 14,1/21,4/37,6
Heating 2
Heating capacity kW 0,68/1,28/2,19 0,68/1,49/2,5 0,84/1,81/2,8 1,08/2,36/4,13 1,33/4,14/4,9 1,44/3,58/4,22 3,09/5,77/7,12 5,15/6,73/9,77
Water flow l/h 117/220/377 117/257/431 145/312/482 186/407/711 229/713/844 248/617/727 532/994/1226 887/1159/1683
Water pressure drop kPa 6,7/19,9/53,4 1,6/5,3/12,2 4,4/15,5/33,3 1,6/16,6/45 3,6/28,9/39,9 7/38,2/52,4 4/13,6/20,6 14,4/23,1/45,6
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 0,53/1,07/1,9 0,56/1,19/2,18 0,68/1,83/2,84 1,19/2,65/3,95 1,23/3,63/4,62 1,78/4,11/4,94 2,48/5,47/6,59 4,96/6,21/9,55
Sensible capacity kW 0,43/0,92/1,69 0,43/0,96/1,76 0,49/1,43/2,21 0,85/1,9/2,83 0,97/2,75/3,45 1,18/3,21/3,83 1,86/4,03/4,96 3,58/4,57/7,21
Water flow l/h 92/185/327 97/206/375 117/315/490 205/457/681 212/625/796 306/707/851 427/942/1136 855/1070/1644
Water pressure drop kPa 2,4/8,4/24,8 1,3/3,7/9,7 1,8/8,9/19,5 7,9/29,6/60,1 2,5/17,9/28,2 5/24,3/34,8 3,3/15,3/22,2 22,8/33,9/73,9
Heating 3
Heating capacity kW 0,62/1,12/1,79 0,75/1,24/1,88 1,39/2,02/2,55 1,67/2,81/3,77 2,21/3,35/4,08 1,41/3,1/3,68 3,46/4,8/5,7 6,42/8,47/13,60
Water flow l/h 54/96/154 65/107/162 120/174/220 144/242/324 190/288/352 122/267/317 298/413/491 553/729/1170
Water pressure drop kPa <1/1,6/3,8 <1/1,7/3,9 3,2/5,6/8,2 8,6/21,3/36,2 6,7/13,6/19,5 4,2/14,5/19,4 32,4/56,4/76,4 23,3/38,2/91,5
Sound LevelsGlobal sound power level dB(A) 34/47/60 34/47/60 31/50/59 29/44/52 30/51/57 32/54/58 40/54/59 51/56/64
Global sound pressure level 4 dB(A) 20/36/52 26/38/51 22/39/51 19/34/41 17/42/48 20/45/47 27/42/50 39/42/48
NR 4 dB(A) 17/30/46 18/36/45 18/36/48 <16/32/38 <16/38/43 <16/41/45 23/37/46 34/44/46
Fan(s)
Number 1 1 1 2 2 2 2 3
Air flow - 2 pipes m³/h 108/228/417 98/234/413 185/384/570 170/412/678 203/645/816 245/737/912 417/827/1028 685/927/1398
Air flow - 4 pipes m³/h 91/199/379 84/200/380 155/346/526 148/369/627 185/587/755 205/668/845 390/777/969 660/884/1548
Filter G2
Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz
Voltage V 2/5/10 2/5/10 2/6/10 2/5/10 2/7/10 2/7/10 4/8/10 3/4.1/6.4
Motor Absorbed Power - 2 pipes W 5/11/41 5/13/41 4/16/41 2/13/43 2/24/46 2/30/54 11/44/77 23/42/108
Motor Absorbed Power - 4 pipes W 5/11/39 5/13/40 4/15/40 2/15/42 2/23/44 2/28/52 11/43/74 22/41/116
Electrical heater (max.) W 500 500 500/1000 1250/2500 1250/2500 1250/2500 1000/2000 1500/3000
Water ConnectionsType Female gas threaded
2 pipes or 4 pipes “cooling” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’
4 pipes “heating” inch 1/2’’
Weight and DimensionsWeight kg 19 19 22,5 29 32 37 37 52
Dimensions (LxWxH) without feet mm 766x477x225 766x477x225 951x477x225 1136x477x225 1321x477x225 1506x477x225 1321x577x225 1508x578x225
| Water Terminals148
Fan coil unitsCooling and heatingSysCoil Comfort
Technical features Cooling Capacity from 0,7 to 8,1 kW Heating Capacity from 0,7 to 10,3 kW 8 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configurations Universal installation units (vertical or ceiling exposed)
without cabinet
Product Advantages Ease of installation Streamlined design and elaborate finish enabling
harmonious integration 5-speed AC fan motor(s) Very low operating acoustical levels Airflow rate between 95 and 1.397 m³/h
Main accessories and options 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump Discharge/return plenum with duct Electrical heater Front air intake Front/Back/Floor air intake with manual damper Fuse holder G3 filter Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC remote controls for SysLogic*
HOTELS OFFICES
0,7-8,1 kW 0,7-10,3 kW
WRC remote control
ErP20182018
Operating limitsSysCoil ComfortEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
NEW versions with improved acoustic performances!
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Available from September 2018
Water Terminals |
WAT
ER TE
RMIN
ALS
149
Technical features
With G2 filter and without plenum.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 The sound pressure levels are based on (NR) characteristics of a room having volume of 100 m3 with reverberation of 0,5 seconds.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysCoil Comfort
(without cabinet)
SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80
S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 0,72/1,00/1,45 0,74/1,24/1,68 1,00/1,98/2,5 1,2/2,4/3,18 1,72/3,16/4,63 2,71/4,55/5,82 3,41/6,14/7,27 4,63/6,08/8,13
Sensible capacity kW 0,53/0,77/1,16 0,55/0,93/1,3 0,82/1,52/1,9 0,82/1,77/2,34 1,24/2,23/3,27 1,9/3,3/4,47 2,37/4,44/5,57 3,41/4,57/6,29
Water flow l/h 124/172/250 127/213/289 172/341/430 206/413/547 296/544/798 466/784/1003 587/1058/1252 798/1048/1400
Water pressure drop kPa 10,7/19,5/39,2 1,8/3,9/6,3 3,2/10,2/15,4 5,4/17,1/28 7,5/22,8/46,9 13,9/37,4/60,2 4,8/15,4/21,5 11,9/19,3/32,5
Heating 2
Heating capacity kW 0,7/1,1/1,54 0,72/1,17/1,66 1,05/1,96/2,62 1,17/2,28/3,1 1,72/3,3/4,54 1,91/3,22/4,3 3,49/6,22/7,36 4,95/6,8/9,9
Water flow l/h 121/189/265 124/202/286 181/338/451 202/393/534 296/568/782 329/555/741 601/1071/1268 853/1171/1705
Water pressure drop kPa 7,1/15,2/27,9 1,8/3,6/6,2 3,5/10/16,7 5,2/15,7/26,8 5,6/18,8/34,5 11,7/31,2/54,3 5/15,8/22 13,4/23,5/46,7
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 0,66/0,92/1,3 0,63/1,12/1,56 0,96/1,9/2,4 1,13/2,25/3 1,65/3,03/4,34 2,6/4,39/5,61 3,34/5,92/6,93 4,5/5,92/8,01
Sensible capacity kW 0,48/0,7/1,03 0,47/0,84/1,2 0,79/1,46/1,83 0,76/1,66/2,21 1,19/2,15/3,07 1,82/3,18/4,28 2,32/4,27/5,23 3,3/4,44/6,19
Water flow l/h 114/159/225 109/192/268 165/327/414 194/388/517 284/522/748 449/756/967 575/1019/1193 775/1020/1380
Water pressure drop kPa 8,3/15,2/29,0 1,5/3,4/5,6 3/9,5/14,4 7,2/22,3/36,8 4,2/12,8/25,1 10,3/27,7/44,5 5,9/17,9/24,4 19,3/31,1/53,6
Heating 3
Heating capacity kW 0,65/0,99/1,35 0,75/1,15/1,44 1,34/1,91/2,24 1,32/2,22/2,79 2,03/3,21/4,06 2,01/3,08/3,87 3,7/4,97/5,86 5,66/8,06/10,30
Water flow l/h 56/85/117 65/99/124 116/165/193 114/191/241 175/276/349 173/265/333 318/428/505 487/695/888
Water pressure drop kPa 1,2/2,0/3,1 <1/1,5/2,3 3/5,2/6,6 5,8/14/21,1 5,8/12,6/19,2 7,2/14,3/21,1 36,1/60,1/80,3 18,7/35,1/54,8
Sound LevelsGlobal sound power level dB(A) 33/40/49 31/43/50 30/45/52 30/44/51 34/46/56 38/51/58 43/56/61 50/55/64
Global sound pressure level 4 dB(A) 23/33/43 27/37/43 21/34/42 23/35/42 20/38/47 23/43/52 33/46/51 40/43/55
NR 4 dB(A) 19/30/38 22/33/39 16/29/37 19/30/38 16/34/41 19/40/48 28/41/46 38/41/51
Fan(s)
Number 1 1 1 2 2 2 2 3
Air flow - 2 pipes m³/h 111/190/283 105/179/265 138/274/390 173/357/499 263/486/716 350/640/933 480/893/1064 660/936/1397
Air flow - 4 pipes m³/h 95/168/253 89/161/241 132/263/369 162/335/467 242/466/671 334/614/885 470/859/1012 634/905/1370
Filter G2
Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz
Motor Absorbed Power - 2 pipes W 13/24/36 10/18/29 16/37/45 15/37/56 28/55/72 37/75/105 53/100/147 90/112/188
Motor Absorbed Power - 4 pipes W 13/24/36 10/18/28 16/37/44 15/37/55 28/54/70 37/74/104 53/99/145 90/112/188
Electrical heater (max.) W 500 500 500/1000 1250/2500 1250/2500 1250/2500 1000/2000 1500/3000
Water ConnectionsType Female gas threaded
2 pipes or 4 pipes “cooling” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’
4 pipes “heating” inch 1/2’’
Weight and DimensionsWeight kg 13 13 15,5 22 24 28 29 43
Dimensions (LxWxH) mm 509x430x220 509x430x220 694x430x220 879x430x220 1064x430x220 1249x430x220 1064x530x220 1320x530x220
| Water Terminals150
Fan coil unitsCooling and heatingSysCoil Comfort EC
Technical features Cooling Capacity from 0,5 to 9,6 kW Heating Capacity from 0,6 to 13,6 kW 8 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configurations Universal installation units (vertical or ceiling exposed) without
cabinet
Product Advantages Ease of installation Streamlined design and elaborate finish enabling harmonious
integration Low energy consumption EC fan(s) Very low operating acoustical levels Airflow rate between 91 and 1.548 m³/h
Main accessories and options 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump Discharge/return plenum with duct ECoSpeed3 board for EC fan(s)* Electrical heater Front air intake Front/Back/Floor air intake with manual damper Fuse holder G3 filter Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC remote controls for SysLogic*
HOTELS OFFICES
WRC remote control
0,5-9,6 kW EC Motor
0,6-13,6 kW
ErP20182018
Operating limitsSysCoil Comfort ECEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
NEW versions with improved acoustic performances!
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Available from September 2018
Water Terminals |
WAT
ER TE
RMIN
ALS
151
Technical features
With G2 filter and without plenum.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 The sound pressure levels are based on (NR) characteristics of a room having volume of 100 m3 with reverberation of 0,5 seconds.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysCoil Comfort EC
(without cabinet)
SCC10 SCC20 SCC30 SCC40 SCC50 SCC60 SCC70 SCC80
S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 0,62/1,22/2,07 0,64/1,38/2,36 0,86/2,06/3,09 1,34/2,94/4,19 1,34/3,97/4,98 1,98/4,45/5,24 2,69/5,85/6,9 5,1/6,45/8,8
Sensible capacity kW 0,51/1,05/1,85 0,49/1,12/1,91 0,64/1,61/2,4 0,95/2,1/3,0 1,05/3/3,7 1,35/3,51/4,02 2,01/4,31/5,22 3,69/4,75/6,61
Water flow l/h 107/210/356 110/237/406 148/354/532 230/506/722 231/685/858 341/767/903 463/1008/1189 879/1111/1516
Water pressure drop kPa 8,2/28,2/76,9 1,5/4,6/11 5,0/20,5/42,1 6,4/24,4/46,3 4,9/35,1/53,9 7,7/35,8/49,1 3/14/19,4 14,1/21,4/37,6
Heating 2
Heating capacity kW 0,68/1,28/2,19 0,68/1,49/2,5 0,84/1,81/2,8 1,08/2,36/4,13 1,33/4,14/4,9 1,44/3,58/4,22 3,09/5,77/7,12 5,15/6,73/9,77
Water flow l/h 117/220/377 117/257/431 145/312/482 186/407/711 229/713/844 248/617/727 532/994/1226 887/1159/1683
Water pressure drop kPa 6,7/19,9/53,4 1,6/5,3/12,2 4,4/15,5/33,3 1,6/16,6/45 3,6/28,9/39,9 7/38,2/52,4 4/13,6/20,6 14,4/23,1/45,6
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 0,53/1,07/1,9 0,56/1,19/2,18 0,68/1,83/2,84 1,19/2,65/3,95 1,23/3,63/4,62 1,78/4,11/4,94 2,48/5,47/6,59 4,96/6,21/9,55
Sensible capacity kW 0,43/0,92/1,69 0,43/0,96/1,76 0,49/1,43/2,21 0,85/1,9/2,83 0,97/2,75/3,45 1,18/3,21/3,83 1,86/4,03/4,96 3,58/4,57/7,21
Water flow l/h 92/185/327 97/206/375 117/315/490 205/457/681 212/625/796 306/707/851 427/942/1136 855/1070/1644
Water pressure drop kPa 2,4/8,4/24,8 1,3/3,7/9,7 1,8/8,9/19,5 7,9/29,6/60,1 2,5/17,9/28,2 5/24,3/34,8 3,3/15,3/22,2 22,8/33,9/73,9
Heating 3
Heating capacity kW 0,62/1,12/1,79 0,75/1,24/1,88 1,39/2,02/2,55 1,67/2,81/3,77 2,21/3,35/4,08 1,41/3,1/3,68 3,46/4,8/5,7 6,42/8,47/13,60
Water flow l/h 54/96/154 65/107/162 120/174/220 144/242/324 190/288/352 122/267/317 298/413/491 553/729/1170
Water pressure drop kPa <1/1,6/3,8 <1/1,7/3,9 3,2/5,6/8,2 8,6/21,3/36,2 6,7/13,6/19,5 4,2/14,5/19,4 32,4/56,4/76,4 23,3/38,2/91,5
Sound LevelsGlobal sound power level dB(A) 34/47/60 34/47/60 31/50/59 29/44/52 30/51/57 32/54/58 40/54/59 51/56/64
Global sound pressure level 4 dB(A) 20/36/52 26/38/51 22/39/51 19/34/41 17/42/48 20/45/47 27/42/50 39/42/48
NR 4 dB(A) 17/30/46 18/36/45 18/36/48 <16/32/38 <16/38/43 <16/41/45 23/37/46 34/44/46
Fan(s)
Number 1 1 1 2 2 2 2 3
Air flow - 2 pipes m³/h 108/228/417 98/234/413 185/384/570 170/412/678 203/645/816 245/737/912 417/827/1028 685/927/1398
Air flow - 4 pipes m³/h 91/199/379 84/200/380 155/346/526 148/369/627 185/587/755 205/668/845 390/777/969 660/884/1548
Filter G2
Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz - 230V / 1~ / 60Hz
Voltage V 2/5/10 2/5/10 2/6/10 2/5/10 2/7/10 2/7/10 4/8/10 3/4.1/6.4
Motor Absorbed Power - 2 pipes W 5/11/41 5/13/41 4/16/41 2/13/43 2/24/46 2/30/54 11/44/77 23/42/108
Motor Absorbed Power - 4 pipes W 5/11/39 5/13/40 4/15/40 2/15/42 2/23/44 2/28/52 11/43/74 22/41/116
Electrical heater (max.) W 500 500 500/1000 1250/2500 1250/2500 1250/2500 1000/2000 1500/3000
Water ConnectionsType Female gas threaded
2 pipes or 4 pipes “cooling” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’
4 pipes “heating” inch 1/2’’
Weight and DimensionsWeight kg 13 13 15,5 22 24 28 29 43
Dimensions (LxWxH) mm 509x430x220 509x430x220 694x430x220 879x430x220 1064x430x220 1249x430x220 1064x530x220 1320x530x220
| Water Terminals152
Chilled water cassettes Cooling and heating SysQuare
Technical features Cooling Capacity from 1,4 to 8,6 kW Heating Capacity from 1,1 to 12,8 kW
5 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configuration Cassette
Product Advantages 3-speed AC fan motor Very low operating acoustical levels Easy and quick access, by simply removing the front grille All connections: water, electrical, condensate drain and air
vent cock are located at the same side Galvanized steel sheet with thermal and acoustical insulation,
avoiding condensation on the casing and providing good sound attenuation
Cleanable synthetic-type air filter Electrical box easily accessible, outside of the unit Easy access to the valves installed outside of the unit Fresh air intake connection available Air distribution in adjacent room available Integrated condensate drain lift 3 top pump Irys360 & 180 metallic diffuser available for better aesthetic
and air distribution
HOTELS OFFICES
WRC remote control
1,4-8,6 kW 1,1-12,8 kW
Main accessories and options 2 way or 3 way valves Auxiliary drain pan Electrical heater Fresh air kit Infrared control system IR remote control Modbus communication board for SysLogic* Plastic or metallic IRYS COANDA diffusers (mandatory) SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC wall mounted remote control for Syslogic*
SysQuareEntering water temperature from 2 to 80 °CIndoor air temperature from 5 to 32 °C
Operating limits
NEWErP20182018
IRYS COANDA 180180° air diffusionIRYS COANDA
diffusers
IRYS COANDA 360360° air diffusion
For a unique design & a strong coanda effect
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Water Terminals |
WAT
ER TE
RMIN
ALS
153
Technical features
With G1 filter.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 Information data considering an hypothetical sound attenuation of the room and installation of -9 dB(A).
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysQuareSQ20 SQ30 SQ40 SQ50 SQ60 SQ70
S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 1,54/1,76/2,35 1,88/2,86/3,96 2,78/3,46/4,65 3,35/4,42/6,05 3,69/5,44/7,16 4,03/6,45/8,57Sensible capacity kW 1,28/1,46/1,95 1,41/2,16/3,01 2,10/2,64/3,57 2,58/3,44/4,67 2,66/4,03/5,37 2,95/4,81/6,40Water flow l/h 265/303/404 323/493/683 478/597/801 576/762/1042 636/937/1233 695/1111/1476Water pressure drop kPa 5,5/6,8/10,9 4,4/8,5/14,4 7,8/11,2/18,3 8,3/13/21,9 4,2/7,5/11,5 6,4/13/20,5
Heating 2Heating capacity kW 1,92/2,17/2,74 1,94/3,15/3,68 3,16/3,92/5,28 3,80/5,08/6,84 3,85/6,26/8,51 4,38/7,95/10,30Water flow l/h 331/374/472 334/543/634 544/675/909 655/875/1178 663/1078/1466 754/1369/1771Water pressure drop kPa 6,4/7,7/10,9 4,5/9,3/11,8 7,8/10,8/17,4 8,6/13,5/21,8 4,3/8,9/14,4 6,7/16,8/25,6
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 1,35/1,50/1,97 1,99/2,70/3,35 2,54/3,27/3,97 - 2,96/4,94/6,60 3,16/5,98/7,51Sensible capacity kW 1,18/1,36/1,84 1,49/2,11/2,62 2,04/2,55/3,20 - 2,31/3,78/5,08 2,53/4,64/5,88Water flow l/h 232/25/359 342/465/576 437/563/683 - 511/851/1137 543/1030/1294Water pressure drop kPa 7,5/8,9/13,6 5,2/8,3/11,6 7,5/11,2/15,3 - 6,4/13,9/22,2 7/18,9/27,5
Heating 3
Heating capacity kW 1,09/1,27/1,67 3,10/4,40/5,46 4,32/5,00/5,80 - 5,28/7,79/10,00 6,43/10,10/12,80Water flow l/h 94/109/144 267/379/470 372/431/500 - 455/671/865 554/867/1100Water pressure drop kPa 15/19/30,2 8,1/14/19,9 13,9/17,6/22,5 - 4,7/8,2/12,1 6,2/12,1/17,7
Sound Levels - 2 pipesSound power level dB(A) 36/40/49 35/47/53 42/48/57 35/40/49 38/46/54 40/52/59Sound pressure level 4 dB(A) 27/31/40 26/35/44 33/39/48 26/31/40 29/37/45 31/43/50NR 4 dB(A) 23/27/35 20/30/39 28/34/43 21/26/35 22/32/40 25/38/50Sound Levels - 4 pipesSound power level dB(A) 36/40/49 35/47/53 42/48/57 - 38/46/54 40/52/59Sound pressure level 4 dB(A) 27/31/40 26/35/44 33/39/48 - 29/37/45 31/43/50NR 4 dB(A) 23/27/35 20/30/39 28/34/43 - 22/32/40 25/38/45
Fan
Number 1Air flow m³/h 360/450/659 320/504/734 486/626/900 529/720/979 500/824/1159 601/1080/1447Filter G1Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz
Motor Absorbed Power - 2 pipes W 25/35/58 17/34/58 38/58/99 28/41/66 34/61/88 44/92/125Motor Absorbed Power - 4 pipes W 25/35/58 17/34/58 38/58/99 - 34/61/88 44/92/125Electrical heater W 1380 2300 2300 2760 2760 2760 Water ConnectionsType Female gas threaded2 pipes or 4 pipes “cooling” inch 3/4’’ 3/4’’ 3/4’’ 1’’ 1’’ 1’’4 pipes “heating” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’Weight and DimensionsWeight (without valve) kg 14,8 16,5 16,5 37,1 37,1 39,6
Dimensions - LxWxH(with metallic diffusers)
IRYS COANDA 180 mm 595x595x353 595x595x353 595x595x353 849x849x366 849x849x366 849x849x366IRYS COANDA 360 mm 595x595x341 595x595x341 595x595x341 849x849x358 849x849x358 849x849x358
Dimensions - LxWxH(with plastic grid) mm 720x720x334 720x720x334 720x720x334 960x960x339 960x960x339 960x960x339
| Water Terminals154
Chilled water cassettes Cooling and heating SysQuare EC
Technical features Cooling Capacity from 1,4 to 9,4 kW Heating Capacity from 1,1 to 14,0 kW 5 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configuration Cassette
Product Advantages Low energy consumption EC fan Very low operating acoustical levels Easy and quick access, by simply removing the front grille All connections: water, electrical, condensate drain and air
vent cock are located at the same side Galvanized steel sheet with thermal and acoustical insulation,
avoiding condensation on the casing and providing good sound attenuation
Cleanable synthetic-type air filter Electrical box easily accessible, outside of the unit Easy access to the valves installed outside of the unit Fresh air intake connection available Air distribution in adjacent room available Integrated condensate drain lift 3 top pump Irys360 & 180 metallic diffuser available for better aesthetic
and air distribution
HOTELS OFFICES
Main accessories and options 2 way or 3 way valves Auxiliary drain pan ECoSpeed3 board for EC fan(s)* Electrical heater Fresh air kit Infrared control system IR remote control Modbus communication board for SysLogic* Plastic or metallic IRYS COANDA diffusers (mandatory) SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC wall mounted remote control for Syslogic*
1,4-9,6 kW Motor EC
1,1-14,0 kW
SysQuare ECEntering water temperature from 2 to 80 °CIndoor air temperature from 5 to 32 °C
Operating limits
NEW
ErP20182018
WRC remote control
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
IRYS COANDA 180180° air diffusionIRYS COANDA
diffusers
IRYS COANDA 360360° air diffusion
For a unique design & a strong coanda effect
Water Terminals |
WAT
ER TE
RMIN
ALS
155
Technical features
With G1 filter.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 Information data considering an hypothetical sound attenuation of the room and installation of -9 dB(A).
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
SysQuare ECSQ20 SQ30 SQ40 SQ50 SQ60 SQ70
S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 *
Capacities - 2 pipes
Cooling 1
Total cooling capacity kW 1,55/1,78/2,38 1,89/2,88/3,99 2,80/3,50/4,69 3,36/4,44/6,09 3,71/5,48/7,22 4,06/6,50/9,58Sensible capacity kW 1,29/1,49/1,98 1,42/2,18/3,04 2,13/2,67/3,61 2,60/3,46/4,72 2,68/4,07/5,44 2,98/4,86/7,15Water flow l/h 267/306/409 325/497/688 481/604/808 579/765/1050 640/944/1243 700/1119/1649Water pressure drop kPa 5,6/6,9/11,2 4,4/8,6/14,6 7,9/11,4/18,6 8,4/13,1/22,2 4,3/7,6/11,7 6,4/13,1/24,6
Heating 2Heating capacity kW 1,92/2,17/2,74 1,94/3,15/3,68 3,16/3,92/5,28 3,80/5,08/6,84 3,85/6,26/8,51 4,38/7,95/11,0Water flow l/h 331/374/472 334/543/634 544/675/909 655/875/1178 663/1078/1466 754/1369/1900Water pressure drop kPa 6,4/7,7/10,9 4,5/9,3/11,8 7,8/10,8/17,4 8,6/13,5/21,8 4,3/8,9/14,4 6,7/16,8/28,8
Capacities - 4 pipes
Cooling 1
Total cooling capacity kW 1,36/1,52/2,00 2,00/2,70/3,37 2,57/3,23/4,01 - 2,99/4,98/6,64 3,19/6,04/7,93Sensible capacity kW 1,19/1,39/1,86 1,50/2,04/2,64 2,06/2,59/3,29 - 2,33/3,82/5,12 2,57/4,69/6,28Water flow l/h 234/262/344 344/464/581 442/556/690 - 516/858/1144 549/1041/1366Water pressure drop kPa 7,6/9,1/14 5,2/8,2/11,7 7,6/10,9/15,5 - 6,5/14,1/22,4 7,2/19,2/30,1
Heating 3
Heating capacity kW 1,09/1,27/1,67 3,10/4,40/5,46 4,32/5,00/5,80 - 5,28/7,79/10,00 6,43/10,10/14,00Water flow l/h 94/109/144 267/379/470 372/431/500 - 455/671/865 554/867/1205Water pressure drop kPa 15/19/30,2 8,1/14/19,9 13,9/17,6/22,5 - 4,7/8,2/12,1 6,2/12,1/20,5
Sound Levels - 2 pipesSound power level dB(A) 36/40/49 35/47/53 42/48/57 35/40/49 38/46/54 40/52/59Sound pressure level 4 dB(A) 27/31/40 26/35/44 33/39/48 26/31/40 29/37/45 31/43/50NR 4 dB(A) 23/27/35 20/30/39 28/34/43 21/26/35 22/32/40 25/38/45Sound Levels - 4 pipesSound power level dB(A) 36/40/49 35/44/53 42/48/57 - 38/46/54 40/52/59Sound pressure level 4 dB(A) 27/31/40 26/35/44 33/39/48 - 29/37/45 31/43/50NR 4 dB(A) 23/27/35 20/30/39 28/34/43 - 22/32/40 25/38/45
Fan
Number 1Air flow m³/h 360/450/659 320/504/734 486/626/900 529/720/979 500/824/1159 601/1080/1598Filter G1Electrical Data
Power supply V/Ph/Hz 230V / 1~ / 50Hz
Voltage V 2/6/10 2/6/10 2/6/10 2/6/10 2/6/10 2/6/10Motor Absorbed Power - 2 pipes W 9/13/29 7/14/32 13/22/57 7/12/25 9/23/25 11/40/115Motor Absorbed Power - 4 pipes W 9/13/29 7/14/32 13/22/57 - 9/23/46 11/40/115Electrical heater W 1380 2300 2300 2760 2760 2760 Water ConnectionsType Female gas threaded2 pipes or 4-pipe “cooling” inch 3/4’’ 3/4’’ 3/4’’ 1’’ 1’’ 1’’4 pipes “heating” inch 1/2’’ 1/2’’ 1/2’’ 1/2’’ 3/4’’ 3/4’’Weight and DimensionsWeight (without valve) kg 14,8 16,5 16,5 37,1 37,1 39,6
Dimensions - LxWxH(with metallic diffusers)
IRYS COANDA 180 mm 595x595x353 595x595x353 595x595x353 849x849x366 849x849x366 849x849x366IRYS COANDA 360 mm 595x595x341 595x595x341 595x595x341 849x849x358 849x849x358 849x849x358
Dimensions - LxWxH(with plastic grid) mm 720x720x334 720x720x334 720x720x334 960x960x339 960x960x339 960x960x339
| Water Terminals156
High wall chilled water units Cooling and heating Hawair
Technical features Cooling Capacity from 1,0 to 3,9 kW Heating Capacity from 1,4 to 4,1 kW
4 sizes
Version 2-Pipes
Configuration High Wall
Product Advantages 3-speed AC fan motor Aesthetic design suitable for residential and hotel applications
Silent unit for optimum customer comfort Delivered with IR control (RC7 remote control included) and
with or without Integrated 3-way valve. Choice between IR or wall-mounted thermostat Coil with hydrophilic fins to improve the condensate flow
Light unit for easy installation Very easy servicing through removable front plate Cleanable synthetic-type air filter
Indoor unit compatible with all Systemair chilled water production units
Main options and accessories 2 way or 3 way valve ON/OFF Modbus communication board for SysLogic* SysLogic controller (other electromechanical or electronic control
systems also available)* WRC/BRC wall mounted remote control for SysLogic*
HOTELS
1,0-3,9 kW 1,4-4,1 kW
HawairEntering water temperature from 5 to 60°CIndoor air temperature from 6 to 40°C
Operating limits
ErP20182018
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
WRC remote control
Water Terminals |
WAT
ER TE
RMIN
ALS
157
Technical features
With G1 filter.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.
HAWAIR(without valve / 2 Pipes)
HAW007-A HAW009-A HAW018-A HAW022-AS2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 * S2 / S3 / S4 *
Capacities
Cooling 1
Cooling capacity kW 1,00 / 1,34 / 1,67 1,57 / 1,69 / 2,43 2,81 / 2,95 / 3,54 2,92 / 3,11 / 3,89Sensible capacity kW 0,72 / 0,97 / 1,20 1,21 / 1,32 / 1,87 2,12 / 2,26 / 2,74 2,27 / 2,48 / 3,11Water flow l/h 172 / 231 / 287 270 / 291 / 418 483 / 508 / 609 502 / 535 / 669Water pressure drop kPa 18,5 / 24,9 / 30,9 25 / 27/ 40 38,1 / 41,3 / 55,6 31,1 / 33,7 / 45,2
Heating 2
Heating capacity W 1,42 / 1,62 / 1,72 1,57 / 1,88 / 2,53 2,73 / 3,01 / 3,69 2,91 / 3,49 / 4,07Water flow l/h 245 / 279 / 296 270 / 324 / 436 470 / 518 / 636 501 / 601 / 701Water pressure drop kPa 17,7 / 23,3 / 26,5 24,8 / 30,2 / 41,9 34,8 / 40,2 / 54,9 34,6 / 50,7 / 69,7
Sound levelsSound power level dB(A) 45 / 49 / 51 47 / 52 / 57 49 / 53 / 56 53 / 57 / 63Sound pressure level 3 dB(A) 30 / 33 / 35 32 / 36 / 40 39 / 41 / 43 39 / 43 / 48NR 3 dB(A) 32 / 36 / 38 34 / 39 / 44 40 / 43 / 46 43 / 46 / 50FanNumber 1 1 1 1Air flow m³/h 282 / 321 / 360 367 / 413 / 551 532 / 592 / 680 617 / 709 / 850Electrical dataPower supply V/Ph/Hz 230V / 1~ / 50HzMotor Absorbed Power W 39 / 42 / 62 45 / 47 / 59 45 / 50 / 55 50 / 55 / 70Water connectionsType Gas female threadedConnections inch 1/2” 1/2” 1/2” 1/2”Dimensions and WeightDimensions (LxWxH) mm 845 x 275 x 180 845 x 275 x 180 940 x 298 x 200 940 x 298 x 200Weight kg 11 11 13 13
HAWAIR(with valve / 2 Pipes)
HAW009AV HAW022AVS2 / S3 / S4 * S2 / S3 / S4 *
Capacities
Cooling 1
Cooling capacity kW 0,92 / 1,16 / 1,25 2,01 / 2,31 / 2,75Sensible capacity kW 0,61 / 0,92 / 1,07 1,51 / 1,66 / 1,97Water flow l/h 158 / 200 / 215 346 / 397 / 473Water pressure drop kPa 30,8 / 39,4 / 42,6 29,7 / 35,5 / 44,8
Heating 2
Heating capacity W 1,04 / 1,22 / 1,57 2,23 / 2,56 / 3,01Water flow l/h 179 / 210 / 270 384 / 441 / 518Water pressure drop kPa 30,4 / 39,5 / 60,1 30,5 / 49,2 / 80,3
Sound levelsSound power level dB(A) 47 / 52 / 47 54 / 58 / 62Sound pressure level 3 dB(A) 32 / 36 / 40 39 / 43 / 48NR 3 dB(A) 27 / 31 / 37 34 / 37 / 41FanNumber 1 1Air flow m³/h 150 / 250 / 400 290 / 400 / 600Electrical dataPower supply V/Ph/Hz 230V / 1~ / 50HzMotor Absorbed Power W 40 / 40 / 45 55 / 60 / 65Water connectionsType Gas female threadedConnections inch 1/2” 1/2”Dimensions and WeightDimensions (LxWxH) mm 845 x 275 x 180 940 x 298 x 200Weight kg 11 13
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Water Terminals158
Pressure ductable fan coil units Cooling and heating DUCTYS
Technical features Cooling Capacity from 0,8 to 6,7 kW Heating Capacity: from 0,7 to 7,1 kW
5 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configuration Ceiling concealed
Product Advantages Low energy consumption EC fan (ECoSpeed3 board included) Very low height (223 mm) Ease of installation and maintenance Many aeraulic configurations** Static pressure available up to 100 Pa Very low operating acoustical levels Selection of hydraulic and electric service side Configuration flexibility thanks to modular conception
Main options and accessories 2-way or 3-way ON/OFF valve Circuit breaker Condensate drain pump Electrical heater Fresh air intake Fuse holder G2/G3 filter Many airflow configurations ** Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC wall mounted remote control for SysLogic*
OFFICES
WRC remote control
** Many aeraulic configurations
I configurations J configuration
Rectangular return and discharge
Rectangular return and circular discharge
Circular return and discharge
L configuration
U configuration
Circular return and discharge
Circular return and discharge
Circular return and discharge
0,8-6,7 kW
0,7-7,1 kW
Motor EC
DUCTYSEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
Operating limits
ErP20182018
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Water Terminals |
WAT
ER TE
RMIN
ALS
159
Technical features
DUCTYS (EC motor / rectangular return and discharge)
DT10 DT15 DT20 DT25 DT40S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 *
Capacities - 2 Pipes
Cooling 1
Cooling capacity kW 0,84 / 1,65 / 2,04 1,39 / 1,88 / 2,06 1,83 / 2,42 / 2,74 2,42 / 2,77 / 3,2 2,4 / 4,94 / 6,66Sensible capacity kW 0,78 / 1,5 / 1,87 1,16 / 1,6 / 1,96 1,46 / 1,92 / 2,21 1,96 / 2,24 / 2,63 1,8 / 4,1 / 6,13Water flow l/h 144 / 285 / 351 239 / 324 / 355 315 / 416 / 472 416 / 477 / 551 413 / 851 / 1148Water pressure drop kPa 3,1 / 8,8 / 12,4 6,1 / 9,3 / 10,5 9,5 / 15,5 / 19,5 15,9 / 20,5 / 26,8 8,2 / 29,7 / 51,7
Heating 2
Heating capacity kW 0,72 / 2,1 / 2,85 1,45 / 2,07 / 2,55 2,07 / 2,47 / 2,59 2,58 / 3,02 / 3,39 2,4 / 5,1 / 7,06Water flow l/h 123 / 363 / 491 250 / 357 / 439 357 / 425 / 446 444 / 520 / 584 413 / 878 / 1216Water pressure drop kPa 2,5 / 13,1 / 22,0 6,5 / 10,6 / 14,3 11,9 / 16,1 / 17,6 17,9 / 24,1 / 29,9 8,2 / 31,4 / 57,6
Capacities - 4 Pipes
Cooling 1
Cooling capacity kW 0,81 / 1,59 / 1,94 1,34 / 1,78 / 2,18 1,78 / 2,38 / 2,74 2,19 / 2,69 / 2,94 2,22 / 4,76 / 6,37Sensible capacity kW 0,75 / 1,43 / 1,78 1,11 / 1,52 / 1,73 1,42 / 1,9 / 2,22 1,73 / 2,16 / 2,39 1,77 / 4,02 / 5,63Water flow l/h 139 / 274 / 335 231 / 306 / 375 306 / 410 / 472 377 / 463 / 506 382 / 821 / 1097Water pressure drop kPa 2,9 / 8,3 / 11,5 5,8 / 8,5 / 11,4 9,1 / 15,1 / 19,5 13,3 / 19,4 / 22,9 7,2 / 27,8 / 47,5
Heating 3
Heating capacity kW 0,8 / 2,19 / 2,96 1,79 / 2,54 / 2,88 2,6 / 3,02 / 3,12 3,58 / 3,99 / 4,47 2,64 / 5,05 / 6,61Water flow l/h 69 / 189 / 255 154 / 219 / 248 224 / 260 / 269 308 / 344 / 385 227 / 435 / 569Water pressure drop kPa 1,8 / 7,4 / 11,9 4 / 7,5 / 9,4 7,3 / 10,9 / 11,9 14,8 / 18,6 / 23,4 3,5 / 37,3 / 74,3
Sound levels - 2 PipesSound power Return + Radiated 4 dB(A) - 44 / 55 / 60 46 / 57 / 61 50 / 55 / 61 42 / 58 / 68Sound power Discharge 4 dB(A) - 41 / 52 / 58 50 / 57 / 61 50 / 56 / 61 34 / 54 / 70Sound pressure 5 dB(A) <16 / 35 / 38 26 / 37 / 42 31 / 40 / 44 33 / 39 / 44 23 / 39 / 52NR 5 <16 / 30 / 33 21 / 32 / 37 26 / 35 / 39 28 / 34 / 39 18 / 34 / 47Sound levels- 4 PipesSound power Return + Radiated 4 dB(A) - 44 / 55 / 60 46 / 57 / 61 50 / 55 / 61 43 / 58 / 68Sound power Discharge 4 dB(A) - 41 / 52 / 58 50 / 57 / 61 50 / 56 / 61 38 / 54 / 70Sound pressure 5 dB(A) <16 / 35 / 38 26 / 37 / 42 31 / 40 / 44 33 / 39 / 44 24 / 39 / 52NR 5 <16 / 30 / 33 21 / 32 / 37 26 / 35 / 39 28 / 34 / 39 19 / 34 / 47FanNumber 1Air flow - 2 Pipes 4 m³/h 126 / 415 / 564 255 / 383 / 491 360 / 501 / 599 448 / 541 / 642 347 / 848 / 1293Air flow - 4 Pipes 4 m³/h 116 / 390 / 532 228 / 351 / 452 331 / 467 / 560 413 / 503 / 602 319 / 802 / 1228External static pressure - 2 pipes Pa 0 22/50/82 26/50/72 34/50/70 8/50/116External static pressure - 4 pipes Pa 0 21/50/83 25/50/72 34/50/72 8/50/117Electrical dataPower supply V / Ph / Hz 230V / 1~ / 50Hz-60HzVoltage V 2 / 7,35 / 10 3,8 / 6 / 8,2 4,8 / 7,1 / 8,9 3,1 / 3,9 / 4,9 2,1 / 5,5 / 10Motor Absorbed Power - 2 Pipes W 7 / 23 / 41 11 / 29 / 56 19 / 50 / 70 25 / 41 / 64 10 / 62 / 197Motor Absorbed Power - 4 Pipes W 7 / 23 / 40 10 / 28 / 53 18 / 47 / 67 26 / 41 / 69 10 / 60 / 188Electrical heater W 500 600 / 1000 600 / 1000 1000 / 2000 1250 / 2500Water connectionsType Gas Female threadedCooling inch 1/2" 1/2" 1/2" 1/2" 3/4"Heating inch 1/2" 1/2" 1/2" 1/2" 1/2"Dimensions and WeightDimensions without drain pan (LxWxH) - Rect-rect mm 631 x 633 x 223 631 x 733 x 223 631 x 833 x 223 631 x 933 x 223 653 x 1233 x 223
Weight kg 14 16 18 20 19
With G2 (DT15/DT20/DT25) or G3 (DT10/DT40) filter and with Rect. inlet/outlet plenums.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 According to Eurovent 6/10 (Airflow test method) and 8/12 (Sound test method).5 Informative data, considering an hypothetical sound attenuation of the room and installation of 20 dB. Please add 2dB for a non-ducted configuration.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Water Terminals160
High static pressure ductable fan coil units Cooling and heating VH
Technical features Cooling Capacity from 4,1 to 21,9 kW Heating Capacity from 4,7 to 29,6 kW 6 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configuration Ceiling concealed
Product Advantages 5-speed AC fan motor Ease of installation and maintenance High static pressure available up to 220 Pa Very low operating acoustical levels in low speeds Selection of hydraulic and electric service side Configuration flexibility thanks to modular conception Various air intake configuration: rectangular or duct
connections
Main options and accessories 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump Double skin insulation Electrical heater Fresh air intake Fuse holder
4,1-21,9 kW 4,7-29,6 kW
FACTORY
G3/G4 filter Many air inlet and air outlet configurations Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC wall mounted remote control *
WRC remote control
ErP20182018
VHEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
Operating limits
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Water Terminals |
WAT
ER TE
RMIN
ALS
161
Technical features
VH(Circular return and discharge (3x Ø200) for VH07, Rectangular return and discharge from VH15 to VH27)
VH07 VH15 VH18 VH21 VH24 VH27
S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S3 / S5 * S1 / S2 / S3 * S1 / S2 / S3 *
Capacities - 2 Pipes
Cooling 1
Cooling capacity kW 4,42 / 5,31 / 5,58 6,89 / 11,5 / 13,3 6,31 / 11,5 / 13,9 7,07 / 13,7 / 17 14,8 / 46,7 / 19 16,4 / 18,9 / 21,9
Sensible capacity kW 3,14 / 3,97 / 4,25 5,05 / 9,2 / 11,2 4,94 / 9,48 / 11,9 4,93 / 9,94 / 12,5 10,7 / 12,3 / 14,2 11,4 / 13,3 / 15,5
Water flow l/h 762 / 915 / 962 1187 / 1979 / 2289 1087 / 1979 / 2391 1218 / 2357 / 2928 2546 / 2873 / 3268 2820 / 3250 / 3766
Water pressure drop kPa 27,4 / 39,3 / 43,4 7,9 / 19,9 / 26,1 6,8 / 19,6 / 27,6 8,4 / 28,8 / 43,4 14,7 / 18,3 / 23,2 13,6 / 17,6 / 23,1
Heating 2
Heating capacity kW 4,7 / 6,4 / 7,76 6,6 / 12 / 15,5 7,2 / 14 / 18 6,95 / 13,9 / 17,8 15 / 17,4 / 20,9 15,4 / 17,9 / 21,5
Water flow l/h 810 / 1102 / 1337 1137 / 2067 / 2670 1240 / 2411 / 3100 1197 / 2394 / 3064 2584 / 2997 / 3600 2653 / 3083 / 3703
Water pressure drop kPa 24,1 / 43,4 / 63,1 5,8 / 16,8 / 26,8 6 / 16,2 / 24,2 10,7/24,2/32,9 10,9 / 14 / 19,3 10,3 / 13,3 / 18,4
Capacities - 4 Pipes
Cooling 1
Cooling capacity kW 4,05 / 4,83 / 5,07 6,38 / 10,1 / 11,3 6,77 / 11,2 / 12,8 7,74 / 14,4 / 17,4 13,7 / 15,3 / 17,1 14,8 / 16,8 / 19,1
Sensible capacity kW 2,86 / 3,57 / 3,8 4,77 / 8,43 / 10,1 5,02 / 9,14 / 11,1 5,46 / 10,6 / 13,2 10,2 / 11,7 / 13,3 10,7 / 12,3 / 14,2
Water flow l/h 697 / 833 / 874 1098 / 1739 / 1945 1165 / 1928 / 2203 1333 / 2478 / 2994 2357 / 2632 / 2942 2546 / 2890 / 3286
Water pressure drop kPa 31 / 43 / 47 5,7 / 13,5 / 16,7 6,8 / 17,4 / 22,4 10,9 / 35,2 / 50,7 15,3 / 18,8 / 23,3 13,5 / 17 / 21,6
Heating 3
Heating capacity kW 5,5 / 7 / 7,7 9,6 / 17 / 21 9,7 / 17,1 / 21 9,7 / 17,1 / 21 10,9 / 15,2 / 17,33 18,5 / 25 / 29,6
Water flow l/h 474 / 603 / 663 827 / 1464 / 1809 835 / 1473 / 1809 835 / 1473 / 1809 1664 / 2219 / 2563 1593 / 2153 / 2549
Water pressure drop kPa 9,1 / 13 / 15,1 33,3 / 91,3 / 134 20,6 / 55,5 / 80,5 20,6 / 55,5 / 80,5 70,9 / 111 / 141 40,6 / 64,1 / 83,6
Sound levels
Sound power Return + Radiated 4 dB(A) 54 / 60 / 63 52 / 66 / 72 54 / 66 / 74 52 / 66 / 72 65 / 69 / 73 65 / 69 / 73
Sound power Discharge 4 dB(A) 53 / 59 / 62 52 / 64 / 71 52 / 64 / 71 52 / 64 / 71 64 / 67 / 72 64 / 67 / 72
Sound pressure 5 dB(A) 33 / 39 / 42 31 / 45 / 51 31 / 45 / 51 31 / 45 / 51 44 / 48 / 52 44 / 48 / 52
NR 5 27 / 34 / 37 27 / 40 / 47 27 / 40 / 47 27 / 40 / 47 40 / 44 / 48 40 / 44 / 48
Fan
Number 1
Air flow - 2 Pipes 4 m³/h 703 / 974 / 1126 990 / 2110 / 2845 990 / 2110 / 2845 990 / 2110 / 2845 2023 / 2425 / 2944 2023 / 2425 / 2944
Air flow - 4 Pipes 4 m³/h 583 / 834 / 969 990 / 2110 / 2845 990 / 2110 / 2845 990 / 2110 / 2845 2023 / 2425 / 2944 2023 / 2425 / 2944
External static pressure - 2 pipes Pa 26/50/67 11/50/91 11/50/91 11/50/91 35/50/74 35/50/74External static pressure - 4 pipes Pa 24/50/68 11/50/91 11/50/91 11/50/91 35/50/74 35/50/74
Electrical data
Power supply V / Ph / Hz 230V / 1~ / 50Hz-60HzMotor Absorbed Power W 132 / 182 / 222 180 / 421 / 675 180 / 421 / 675 180 / 421 / 675 420 / 530 / 673 420 / 530 / 673Electrical heater (max.) W 2000 3000 3000 3000 3000 3000
Water connections
Type Gas Female threaded Gas Male threaded
Cooling - 2 pipes inch 1/2" 1" 1 1/4" 1 1/4” 1 1/4” 1 1/4”
Cooling - 4 pipes inch 1/2” 1” 1” 1” 1 1/4” 1 1/4”
Heating inch 1/2" 3/4" 3/4" 3/4” 3/4” 3/4”
Dimensions
Rect-rect (LxWxH) mm 698 x 1200 x 250 798 x 1380 x 375 798 x 1380 x 375 798 x 1380 x 375 798 x 1500 x 450 798 x 1500 x 450
Circ-circ (LxWxH) mm 1014 x 1200 x 250 - - - - -
Weight
Rect-rect kg 42 63 65 67 76 80
Circ-circ kg 48 - - - - -
With G3 filter and inlet/outlet plenums (3x⌀200 for VH07, rect. from VH15 to VH27).* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 According to Eurovent 6/10 (Airflow test method) and 8/12 (Sound test method).5 Informative data, considering an hypothetical sound attenuation of the room and installation of 21 dB.
For a precise selection and more technical information
www.sysoftac.com
Sysoft AC
| Water Terminals162
High static pressure ductable fan coil units Cooling and heating VH EC
Technical features Cooling Capacity from 6,6 to 19,9 kW Heating Capacity from 5,9 to 21,4 kW 5 sizes
Versions 2-Pipes 2-Pipes/2-Wires 4-Pipes
Configuration Ceiling concealed
Product Advantages Low energy consumption EC fan Ease of installation and maintenance High static pressure available up to 220 Pa Very low operating acoustical levels in low speeds Selection of hydraulic and electric service side Configuration flexibility thanks to modular conception Various air intake configuration: rectangular or duct
connections
Main options and accessories 2-way or 3-way ON/OFF valves Auxiliary drain pan Circuit breaker Condensate drain pump Double skin insulation ECoSpeed3 board for EC fan Electrical heater Fresh air intake
6,6-19,9 kW
5,9-21,4 kW
FACTORY
Fuse holder G3/G4 filter Many air inlet and air outlet configurations Modbus communication board for SysLogic* Suspension kit SysLogic controller (other electromechanical or electronic
control systems also available)* WRC/BRC wall mounted remote control *
WRC remote control
ErP20182018
VH ECEntering water temperature from 5 to 90 °CIndoor air temperature from 5 to 32 °C
Operating limits
New EC versions
Motor EC
ERP 2018 compliant following COMMISSION REGULATION (EU) No2016/2281 * see pages 164-165 for more details
Water Terminals |
WAT
ER TE
RMIN
ALS
163
Technical features
VH EC(Rectangular return and discharge)
VH15 VH18 VH21 VH24 VH27
S1 / S2 / S3 * S1 / S2 / S3 * S1 / S2 / S3 *2 Pipes : S2 / S3 / S4 *4 Pipes : S1 / S3 / S4 *
Capacities - 2 Pipes
Cooling 1
Cooling capacity kW 7,93 / 10,1 / 11,1 8,98 / 11,7 / 12,8 9,79 / 12,7 / 13,9 14,1 / 16,1 / 17,6 15,8 / 18,1 / 19,9
Sensible capacity kW 6,08 / 8,05 / 8,9 6,71 / 9,02 / 10 7,14 / 9,55 / 10,6 10,8 / 12,4 / 13,7 11,7 / 13,6 / 15,1
Water flow l/h 1366 / 1744 / 1905 1547 / 2010 / 2207 1686 / 2182 / 2393 2425 / 2766 / 3024 2722 / 3120 / 3420
Water pressure drop kPa 10,1 / 15,8 / 18,5 12,6 / 13,1 / 14,6 15,3 / 24,9 / 29,6 13,4 / 17,1 / 20,1 12,8 / 16,4 / 19,3
Heating 2
Heating capacity kW 8,66 / 11,7 / 13 9,48 / 13,1 / 14,6 9,99 / 14,1 / 15,8 15,1 / 17,6 / 19,5 16,4 / 19,1 / 21,4
Water flow l/h 1492 / 2011 / 2232 1633 / 2255 / 2520 1721 / 2428 / 2728 2608 / 3026 / 3365 2824 / 3297 / 3689
Water pressure drop kPa 9,3 / 15,9 / 19,3 8,9 / 14,6 / 17,4 16,7 / 25,5 / 29,5 11 / 14,2 / 17,1 11,5 / 15 / 18,3
Capacities - 4 Pipes
Cooling 1
Cooling capacity kW 6,57 / 8,21 / 8,91 7,4 / 9,26 / 10 8,92 / 11,3 / 12,4 9,51 / 14 / 15,2 10,2 / 15,3 / 16,8
Sensible capacity kW 5,2 / 6,76 / 7,43 5,7 / 7,48 / 8,24 6,66 / 8,75 / 9,64 7,13 / 11 / 12,1 7,52 / 11,8 / 13,1
Water flow l/h 1131 / 1415 / 1536 1275 / 1594 / 1730 1536 / 1952 / 2128 1638 / 2409 / 2624 1749 / 2641 / 2894
Water pressure drop kPa 6 / 9,2 / 10,7 8 / 12,1 / 14,2 14,2 / 22,3 / 26,3 7,7 / 15,9 / 18,7 7 / 14,5 / 17,1
Heating 3
Heating capacity kW 5,85 / 7,45 / 8,13 10 / 12,9 / 14,2 10 / 12,9 / 14,2 8 / 11,9 / 13 7,71 / 11,7 / 12,9
Water flow l/h 504 / 642 / 700 863 / 1112 / 1219 863 / 1112 / 1219 689 / 1026 / 1118 664 / 1010 / 1109
Water pressure drop kPa 14,7 / 21,8 / 25,1 21,8 / 33,8 / 39,6 21,8 / 33,8 / 39,6 20,2 / 34,8 / 39,4 12,2 / 21,2 / 24,2
Sound levels- 2 Pipes
Sound power Return + Radiated 4 dB(A) 56 / 65 / 67 56 / 65 / 67 56 / 65 / 67 67 / 69 / 73 67 / 69 / 73
Sound power Discharge 4 dB(A) 56 / 64 / 65 56 / 64 / 65 56 / 64 / 65 66 / 67 / 72 66 / 67 / 72
Sound pressure 5 dB(A) 35 / 44 / 46 35 / 44 / 46 35 / 44 / 46 46 / 48 / 52 46 / 48 / 52
NR 5 31 / 40 / 42 31 / 40 / 42 31 / 40 / 42 42 / 44 / 48 42 / 44 / 48
Sound levels- 4 Pipes
Sound power Return + Radiated 4 dB(A) 56 / 65 / 67 56 / 65 / 67 56 / 65 / 67 58 / 69 / 73 58 / 69 / 73
Sound power Discharge 4 dB(A) 56 / 64 / 65 56 / 64 / 65 56 / 64 / 65 58 / 67 / 72 58 / 67 / 72
Sound pressure 5 dB(A) 35 / 44 / 46 35 / 44 / 46 35 / 44 / 46 37 / 45 / 52 37 / 45 / 52
NR 5 31 / 40 / 42 31 / 40 / 42 31 / 40 / 42 33 / 44 / 48 33 / 44 / 48
Fan
Number 1
Air flow - 2 Pipes 4 m³/h 1360 / 2044 / 2335 1360 / 2044 / 2335 1360 / 2044 / 2335 2272 / 2700 / 3098 2272 / 2700 / 3098
Air flow - 4 Pipes 4 m³/h 1360 / 2044 / 2335 1360 / 2044 / 2335 1360 / 2044 / 2335 1519 / 2700 / 3098 1519 / 2700 / 3098
External static pressure - 2 pipes Pa 22/50/65 22/50/65 22/50/65 35/50/66 35/50/66External static pressure - 4 pipes Pa 22/50/65 22/50/65 22/50/65 16/50/66 16/50/66
Electrical data
Power supply V / Ph / Hz 230V / 1~ / 50Hz-60Hz
Voltage - 2 Pipes V 2 / 4 / 5 2 / 4 / 5 2 / 4 / 5 4 / 5 / 7 4 / 5 / 7
Voltage - 4 Pipes V 2 / 4 / 5 2 / 4 / 5 2 / 4 / 5 2 / 5 / 7 2 / 5 / 7
Motor Absorbed Power - 2 Pipes W 61 / 172 / 246 61 / 172 / 246 61 / 172 / 246 155 / 237 / 364 155 / 237 / 364
Motor Absorbed Power - 4 Pipes W 61 / 172 / 246 61 / 172 / 246 61 / 172 / 246 57 / 237 / 364 57 / 237 / 364
Electrical heater (max.) W 3000 3000 3000 3000 3000
Water connections
Type Gas Male threaded
Cooling - 2 pipes inch 1" 1 1/4" 1 1/4” 1 1/4” 1 1/4”
Cooling - 4 pipes inch 1” 1” 1” 1 1/4” 1 1/4”
Heating inch 3/4" 3/4" 3/4” 3/4” 3/4”
Dimensions
Rect-rect (LxWxH) mm 798 x 1380 x 375 798 x 1380 x 375 798 x 1380 x 375 798 x 1500 x 450 798 x 1500 x 450
Weight
Rect-rect kg 63 65 67 76 80
With G3 filter and inlet/outlet rect. plenums.* Standard factory set speeds with SysLogic controller.1 According to Eurovent standard. Air: 27°C DB/19°C WB, Water in/out: 7°C/12°C.2 According to Eurovent standard. Air: 20°C, Water in/out: 45°C/40°C.3 According to Eurovent standard. Air: 20°C, Water in/out: 65°C/55°C.4 According to Eurovent 6/10 (Airflow test method) and 8/12 (Sound test method).5 Informative data, considering an hypothetical sound attenuation of the room and installation of 21 dB.
| Water Terminals164
Water Terminal Control
Electro-Mechanical Control
A full range dedicated to your needs
CMV TBMV TRM-VP TRM-FA
System CMV TBMV TRM-VP TRM-FA TAE 20 SYSLOGIC2 Pipes Reversible + valves2 Pipes / 2 Wires + valves2 Pipes / 2 Wires reversible + valves4 Pipes + valvesNo valves (Not recommended)ActionChange over Manual Manual Manual Automatic Manual or automaticFan speed selection Manual Manual Manual Manual Manual or automatic
Fan action Continuous fan1 Cycling fan2 Continuous fan1 Cycling fan2 Continuous1 or cycling fan2
Continuous or cycling fan2
Master/slaves Up to 15 slaves with only one control device
Fan CompatibilityACEC - 3 operating speeds (with ECoSpeed 3 board)EC - 100% controllable via a 0-10V signal
1 Continuous Fan: Fan runs continuously in cooling or heating mode.2 Cycling Fan: Fan stops and starts with temperature demand.
Water Terminals |
WAT
ER TE
RMIN
ALS
165
MB2 - Modbus Board This card allow the connection to
a Modbus communication protocol The MB2 card gives an individual
adress to each fan coil inside the communication bus system
Programmation with parameters
Electronic Control
TAE 20 SYSLOGIC
OR
BRCBasic remote control Fan speed regulation ON/OFF Temperature set point
TAE 20
A full range dedicated to your needs
System CMV TBMV TRM-VP TRM-FA TAE 20 SYSLOGIC2 Pipes Reversible + valves2 Pipes / 2 Wires + valves2 Pipes / 2 Wires reversible + valves4 Pipes + valvesNo valves (Not recommended)ActionChange over Manual Manual Manual Automatic Manual or automaticFan speed selection Manual Manual Manual Manual Manual or automatic
Fan action Continuous fan1 Cycling fan2 Continuous fan1 Cycling fan2 Continuous1 or cycling fan2
Continuous or cycling fan2
Master/slaves Up to 15 slaves with only one control device
Fan CompatibilityACEC - 3 operating speeds (with ECoSpeed 3 board)EC - 100% controllable via a 0-10V signal
WRC / MRCWired remote control Two-way communication Advanced Control Performance Temperature sensor included Display of temperature Selection of the speed Wall mounted (WRC) or mounted
into the unit (MRC)
| Water Source Heat Pumps166
Water Source Heat Pumps
SYSEFTYS 2,1-3,0 kW 2,7-3,6 kW R407C Rotary EC MotorPage 170
SYSCW-AR 1,9-2,7 kW 2,4-3,2 kW R407C Rotary EC MotorPage 172
SYSHRW 5,3-30,0 kW 5,8-38,1 kW R407C Rotary/Scroll EC Motor (upon request)Page 174
N E W !
THEmodels.
VERY HIGH ENERGY
EFFICIENCY
(Très Haute Efficacité
énergétique)
complem
entary range
In line with BREEAM
requirements !
Water Source Heat Pumps |
WAT
ER S
OURC
E HE
AT P
UMPS
167
Product Family Cooling capacity Acoustic Nominal air flow Pressure Fan Size (LxWxH) mm
SYSE
FTYS
FT 2000 2,1 kW NR 32 at MS
451 m³/h at HS
50Pa at HS EC
900x530x240
FT 2500 2,4 kW NR 34
at MS503 m³/h
at HS 900x530x240
FT 3000 3,0 kW NR 37
at MS605 m³/h
at HS 900x530x240
SYSC
W-A
R
CW-AR 07 1,9 kW NR 37
at MS400 m³/h
at HS
0 Pa AC/EC
1.138x251x821*
CW-AR 09 2,1 kW NR 38
at MS460 m³/h
at HS 1.138x251x821*
CW-AR 12 2,7 kW NR 40
at MS510 m³/h
at HS 1.138x251x821*
SYSH
RW
19 5,3 kW NR 42
at MS1.250 m³/h
at HS>50 Pa at HS
AC/EC upon request
900x600x439
27 7,4 kW NR 44
at MS1.185 m³/h
at HS>50 Pa at HS
1.050x660x460
27 THE 7,5 kW NR 44
at MS1.180 m3/h
at HS>50 Pa at HS
30 8,7 kW NR 43
at MS1.490 m³/h
at HS>100 Pa
at HS
30 THE 8,9 kW NR 43
at MS1.500 m3/h
at HS>100 Pa
at HS
36 10,1 kW NR 44
at MS1.580 m³/h
at HS>100 Pa
at HS
36 THE 11,1 kW NR 44
at MS1.580 m3/h
at HS>100 Pa
at HS
1.250x705x513
42 11,4 kW NR 44
at MS2.040 m³/h
at HS>100 Pa
at HS
42 THE 12,5 kW NR 44
at MS2.040 m3/h
at HS>100 Pa
at HS
48 13,0 kW NR 47
at MS2.750 m³/h
at HS>100 Pa
at HS
60 14,3 kW NR 47
at MS2.840 m³/h
at HS>100 Pa
at HS
60 THE 16,7 kW NR 47
at MS2.840 m3/h
at HS>100 Pa
at HS 1.250x705x583
72 17,1 kW NR 48
at MS3.570 m³/h
at HS>100 Pa
at HS 1.250x705x513
72 THE 20,6 kW NR 48
at MS3.800 m3/h
at HS>100 Pa
at HS
1.680x955x77096
21,7 kW NR 56
at HS4.700 m³/h
at HS>100 Pa
at HS
96 THE 24,5 kW NR 56
at MS4.700 m3/h
at HS>100 Pa
at HS
120 30,0 kW NR 57
at HS5.600 m³/h
at HS>200 Pa
at HS
NEW
NEW
Selection guide Water Source Heat Pumps
Ideal solution for refurbishment, and R22 units replacement, as well as for new applications.
Advance scroll technology
Rotary or scroll springs compressor
TECHNOLOGY AND RELIABILITYStantard protective devices: Flow switch/pressostat on hydraulic circuit LP pressure switch Fuse holder
* Standard with cabinet
NEW
NEW
NEW
NEW
NEW
| Water Source Heat Pumps168
Product Advantages
Measurement of the room air temperature Anti-short cycle to protect the compressor Variable sequential start-up function avoiding a power surge Emergency shut-down / stand-by / night setback Automatic HP reset pressure and/or lack of water flowrate Automatic BP reset pressure Default isothermal motor ventilator Anti-freeze safety function Low temperature limit in cooling/heating mode High temperature limit in cooling/heating mode Antifreeze default in cooling mode Managing of motorized water valves
RCX remote control Main functions
LCD operation display START/STOP button Display of the room temperature Operation mode selection button: COOLING, HEATING,
AUTO COOL/HEAT, DRY, FAN Room temperature UP/DOWN buttons Airflow direction MANUAL positioning control /AUTO-CONTROL buttons FAN SPEED and AUTO FAN buttons TIMER SET / CLEAR / UP / DOWN buttons NIGHT button Infrared signal transmitter Master/slaves control up to 10 units with only one remote control
STORM2 Stand-alone control system
Water Source Heat Pumps |
WAT
ER S
OURC
E HE
AT P
UMPS
169
Operating mode • OFF • Comfort • ECO
Function type • Summer • Winter • Ventilation • Auto changeover (adjustment of the automatic
mode according to the setpoint)
Communication • Modbus RTU • BACnet MSTP
Ventilation • Compatibility: 3-speed AC fan motor or EC fan motor • Manual speed (3 levels) • Automatic speed
Setpoint • Extract air temperature • Room thermostat • BMS
Connections: Terminal with removable screw connectorsPower supply: 24V AC 45 65 Hz - 1.6A max (transformer included)Operating temperature: from -40 to 70°C
RoomThermostat
Main functions of the thermostat• ON/OFF• Comfort / ECO modes• Operating mode setting• Setpoint adjustment• Room temperature (OFF)• Ventilation setting (manual or automatic)• Time display and setting• Sum alarm• Zoning (up to 15 units)• Scheduling
Control system with communication protocols
| Water Source Heat Pumps170
SYSEFTYS
Water inlet temperatureCooling
Min 18 °CMax 50°C
HeatingMin 9°CMax 32°C
Air inlet temperatureCooling
Min 21°C db / 15°C wbMax 32°C db / 23°C wb
HeatingMin 15°CMax 25°C
Maximum operating pressure 10 bars*
Water source heat pumpsCooling and heatingSYSEFTYS
Technical features Cooling Capacity from 2,1 to 3,0 kW Heating Capacity from 2,7 to 3,6 kW
Sizes: 3 models, 1 casings
Versions H: Reversible (with or without electrical heating) L: Cooling (with or without electrical heating)
Configuration Horizontal concealed installation
Product Advantages A robust coaxial heat exchanger in presence of loaded water Extended operating limits High energy performances, with EC motor and high COP/EER Stand-alone STORM2 electronic control 1
Coil at the outlet to avoid the installation of a siphon Easy access to components through wide removable panels Many aeraulic and hydraulic configurations to easily replace
units already on site Acoustic insulation and an isolated compressor mounted
on spring for an optimal acoustic comfort Anti-corrosion treated drain pan Low height < 250 mm
Operating limits
HOTELS OFFICES
2,1-3,0 kW R407C
2,7-3,6 kW
Main options and accessories Circuit breaker Control with communication protocols 1
Electrical heater G2/ M1 filter General alarm dry contact Many air inlet/outlet configurations Motorized water valve Quick connector RCX remote control for STORM2 1
Remote for control with communication protocols 1
Room sensor Water flow switch
Rotary
RCX remote control (for STORM2 electronic control)
EC Motor
* Flow switch limit (optional)1 See pages 168-169 for more details.
Water Source Heat Pumps |
WAT
ER S
OURC
E HE
AT P
UMPS
171
Technical features
1 Nominal cooling capacities based on entering air temperature of 27 °C dry bulb, 19 °C wet bulb with entering water temperature of 30 °C.2 Nominal heating capacities based on entering air temperature of 20 °C dry bulb, 15 °C wet bulb with entering water temperature of 20 °C.3 Power input at nominal conditions (compressor + fan at high speed).4 Electric heating coil is available for SH & RH versions.5 Nominal currents are given at +/- 5%.6 Starting currents are given at +/- 10%.7 Following EN14511.* Informative data, considering an hypothetical sound attenuation of the room and installation of 21 dB.** Flow switch limit (optional).
SYSEFTYS 2000 2500 3000Total cooling capacities 1 W 2.057 2.405 2.983Sensible cooling capacities 1 W 1.686 1.983 2.346Heating capacities 2 W 2.706 2.997 3.558COP compressor 2 4,12 4,17 4,30EER compressor 1 3,88 4,13 3,85COP 7 3,84 3,82 3,85EER 7 3,65 3,71 3,39Fan Nominal air flow m³/h 451 503 605Power motor W 65 66 105Air filter - Number / Efficiency 1 / G2 (optional)Hydraulic circuitNumber of heat exchanger 1Maximum water pressure bar 10**Nominal water flow l/h 419 456 623Water pressure drop at nominal water flow kPa 11 13 23Water pressure drop at nominal water flow with valve kPa 27 30 44Hydraulic connections - Inlet/Outlet inch Male ISO G 1/2’’ INTCondensate outlet - External Ø mm 16Refrigerant circuitNumber of circuit 1Compressor Type RotaryElectrical dataElectrical power supply V / Ph / Hz 230V / 1~ / 50HzPower input - Cooling mode 3 W 595 648 879Power input - Heating mode 3 W 722 785 932Electric heating coil - Number/Capacity 4 -/W 1/1.200 1/1.600 1/2.000Compressor nominal current 5 A 2,8 3,0 4,0Compressor starting current 6 A 16 16 18,9Sound levels (LS/MS/HS)Sound Power - Return + Radiated dB(A) 55/57/59 56/58/60 56/58/62Sound Power - Discharge dB(A) 53/55/56 54/56/58 58/61/65Sound Pressure* dB(A) 34/36/38 35/37/40 37/40/44NR* dB(A) 30/32/34 31/34/36 34/37/42 WeightWeight - Operating kg 48 48 48 Dimensions Dimensions (LxWxH) mm 900x530x240 900x530x240 900x530x240
| Water Source Heat Pumps172
SYSCW-AR
Water inlet temperatureCooling
Min 23°CMax 42°C
HeatingMin 12°CMax 34°C *
Return Air temperatureCooling
Min 21°C db/15°C wbMax 32°C db/23°C wb
HeatingMin 15°CMax 27°C
Maximum operating pressure 10 bars **
Water source heat pumpsCooling and heating SYSCW-AR
Operating limits
Technical features Cooling Capacity from 1,9 to 2,7 kW Heating Capacity from 2,4 to 3,2 kW 3 sizes
Versions H: Reversible
VC: standard with cabinet VCL: low height with cabinet VN: standard without cabinet VNL: low height without cabinet
Configurations Vertical console cabinet Vertical concealed without cabinet
Product Advantages A coaxial heat exchanger robust in presence of loaded water
control Many hydraulic and electrical available configurations High efficiency vertical units with high COP Design and elaborate finish enabling harmonious integration Low consumption EC fan motor or 3-speed AC fan motor Stand-alone STORM2 electronic control with RCX remote control1
Brazed stainless steel plate heat exchanger for improved efficiency
Easy access to components through a front panel Ease of installation through selection of service side Direct access to Schrader valves (HP & LP) Flow switch for antifreeze protection Anti-corrosion treated drain pan
HOTELS OFFICES
1,9-2,7 kW R407C
2,4-3,2 kW Rotary
Main options and accessories Bottom return air with feet Control with communication protocols 1
EC fan General remote alarm contact Left hydraulic and electrical connexions FTG grille for cabinet Remote for control with communication protocols1
Remote thermostat mounted Thermal overload
EC Motor
RCX remote control (for STORM2 electronic control)
* 32°C for SYSCW-AR 07 in low speed** Flow switch limit1 See pages 168-169 for more details.
Water Source Heat Pumps |
WAT
ER S
OURC
E HE
AT P
UMPS
173
SYSCW-AR 07 09 12Total cooling capacity1 W 1.942 2.136 2.743Sensible cooling capacity1 W 1.526 1.775 2.340Heating capacity2 W 2.431 2.542 3.156COP 7 3,56 3,74 3,49EER 7 3,41 3,52 3,25Fan Airflow (LS/MS/HS) m³/h 250/340/400 340/400/460 400/460/510Motor power W 75 75 75Air filter - Number/Efficiency 1/G2Hydraulic circuitNumber of plate heat exchanger Nbr 1Maximum water pressure bar 10*Nominal water flow l/h 428,4 478,8 615,6
Water pressure drop at nominal water flow kPa 5 3,4 12
Hydraulic connections - inlet/outlet inch ISO G 1/2” INTCondensate outlet - external ø mm 15x20Refrigerant CircuitNumber of circuit 1Compressor Type RotaryElectrical DataPower supply V/Ph/Hz 230V / 1~ / 50HzPower input (cooling mode)3 W 598 647 892Power input (heating mode)3 W 710 720 954Compressor nominal current4 A 2,8 3 4Compressor starting current5 A 16 16 18,9Sound Levels (LS/MS/HS)Sound power level dB(A) 49/50/51 50/51/53 51/53/54Sound pressure level6 dB(A) 41/42/43 42/43/45 43/45/46NR6 dB(A) 36/37/38 37/38/40 38/40/41Dimensions with feet (LxWxH)Standard with cabinet (CAR) mm 1.138 x 251 x 821Low height with cabinet (CARB) mm 1.323 x 251 x 683Standard without cabinet (NU) mm 1.086 x 229 x 769Low height without cabinet (NUB) mm 1.184,5 x 229 x 624WeightWithout cabinet / with cabinet kg 55/70 58/73 60/75
Technical features
1 Nominal cooling capacities based on: entering air temperature of 27°C DB/19°C WB, with entering water temperature of 30°C.2 Nominal heating capacities based on: entering air temperature of 20°C DB/15°C WB, with entering water temperature of 20°C.3 Absorbed power (compressor + fan) at nominal conditions.4 Nominal currents are given at +/- 5%.5 Starting currents are given at +/- 10%.6 Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.7 Following EN14511.* Flow switch limit.
| Water Source Heat Pumps174
SYSHRW 19-72 96-120
Water inlet temperatureCooling
Min 18°C 20°CMax 44°C 48°C
HeatingMin 13°CMax 34°C
Return Air temperatureCooling
Min 21°C db/15°C wbMax 38°C db/28°C wb 38°C db/28°C wb
HeatingMin 15°CMax 27°C 25°C
Maximum operating pressure 16 bars*
Water source heat pumpsCooling and heatingSYSHRW
Technical features Cooling Capacity from 5,3 to 30,0 kW Heating Capacity from 5,8 to 38,1 kW
10 sizes Versions THE: Very High Energy Efficiency
H: Reversible (with or without electrical heating) L: Cooling (with or without electrical heating)
Configuration Horizontal concealed installation
Product Advantages A heat exchanger with brazed stainless steel plates
High efficiency horizontal units with high COP/EER With the new THE models, each size of the SYSHRW range is
now in line with BREEAM requirements :- SFP < 750 W/m3/s (SFP 2 cat. according to EN13779)- COP > 4,2- EER > 4,0
Stand-alone STORM2 electronic control with RCX remote control1 Extended operating limits G2/M1 filter Compressor mounted on anti-vibration rubber pads Easy access to components through wide removable panels In-line or perpendicular air blowing
Operating limits
SHOPPING CENTERS
5,3-30,0 kW R407C
5,8-38,1 kW Rotary/Scroll
Differential pressure switch for antifreeze protection Bi-flow thermostatic expansion valve Anti-corrosion treated drain pan
Float-type safety system to protect against condensate overflow
Main options and accessories Electrical heater General alarm dry contact
Main switch ModBus Communication interface board for STORM2 Motorized water valve
Room sensor
EC Motor (upon request)
N E W ! THEmodels.
VERY HIGH ENERGY
EFFICIENCY
(Très Haute Efficacité
énergétique)
complem
entary range
In line with BREEAM
requirements !
RCX remote control (for STORM2 electronic control)
* Shut off valve limit (optional)1 See pages 168-169 for more details.
Water Source Heat Pumps |
WAT
ER S
OURC
E HE
AT P
UMPS
175
Technical features
1 Nominal cooling capacities based on : entering air temperature of 27 °C dry bulb, 19 °C wet bulb with entering water temperature of 30°C.2 Nominal heating capacities based on : entering air temperature of 20 °C dry bulb, 15 °C wet bulb with entering water temperature of 20°C.3 Absorbed power (compressor + fan) at nominal conditions.4 Electric heating coil is an optional feature available for SH & RH versions.5 Nominal currents are given at +/- 5%.6 Starting currents are given at +/- 10%.7 Following EN14511.8 Shut off valve limit (optional).
SYSHRW 19 27 27THE 30 30
THE 36 36 THE 42 42
THE 48 60 60 THE 72 72
THE 96 96 THE 120
Total cooling capacities 1 W 5.278 7.419 7.320 8.691 8.710 10.138 11.060 11.366 12.500 12.965 14.344 16.700 17.174 20.600 21.743 24.500 29.951
Sensible cooling capacities 1 W 4.257 5.824 5.600 6.315 6.676 7.278 9.070 8.849 9.542 10.051 10.988 13.900 13.536 17.700 17.986 19.500 24.413
Heating capacities 2 W 5.826 8.342 9.252 9.759 9.960 11.036 12.200 14.422 14.450 14.904 16.147 18.800 21.500 22.600 26.637 28.500 38.109
COP compressor 2 4,20 3,97 4,30 3,78 4,80 3,63 4,38 4,35 5,02 4,5 3,81 4,49 3,59 4,21 3,75 4,51 4,28
EER compressor 1 4,00 3,93 4,18 3,85 4,45 3,86 4,44 3,81 4,43 4,2 3,52 4,96 3,48 4,62 3,94 4,75 4,18
COP 7 4,40 3,69 4,21 3,50 4,30 3,38 4,28 3,84 4,36 4,25 3,33 4,20 3,15 4,23 3,54 4,46 4,25
EER 7 4,20 3,72 4,00 3,77 4,15 3,77 4,31 3,44 4,00 4,03 3,23 4,44 3,26 4,74 3,84 4,61 4,21
Fan
Nominal air flow m³/h 1.250 1.190 1.180 1.490 1.500 1.580 1.580 2.040 2.040 2.750 2.840 2.840 3.570 3.800 4.700 4.700 5.600
Motor Power W 450 450 230 950 400 950 418 950 601 1.500 1.500 911 1.500 820 1.100 796 1.500
Air filters - Number / Efficiency 2 / G2
Hydraulic circuit
Number of plate heat exchanger 1
Maximum water pressure bar 16 8
Nominal water flow l/h 921 1.540 1.620 1.764 1.800 2.030 2.306 2.592 2.600 2.822 3.348 3.550 3.924 4.300 4.860 4.960 6.408
WPD at nominal water flow kPa 13 17 13 23 20 25 21 33 28 34 40 35 61 50 55 55 80,5
WPD at nominal water flow with valve kPa 16 23 16 33 28 39 30 55 42 60 77 63 112 87 133 130 250
Hydraulic connections - Inlet / Outlet inch ISO G 3/4” INTISO G 1”1/4
ISO G 3/4” INT
ISO G 1”1/4
Condensate outlet - External Ø mm 19 22
Refrigerant circuit
Number of circuit 1
Compressor Type Rotary Scroll
Electrical data
Electrical power supply V / Ph / Hz
230V / 1~ / 50Hz ±10%
400V / 3~ / 50Hz +Neutral
Power input - Cooling mode 3 W 1.557 2.118 1.981 2.658 2.357 3.044 2.909 3.584 3.423 4.200 4.989 4.278 6.280 5.279 6.316 5.954 8.547
Power input - Heating mode 3 W 1.611 2.332 2.382 2.983 2.475 3.460 3.203 3.920 3.479 4.300 5.150 5.098 7.347 6.188 7.895 7.115 10.224
Electrical heating coil - Number/Capacity 4 -/W
2/1.500+750
1/3.750
1/3.750
1/3.750
1/3.750
1/4.500
1/4.500
1/5.500
1/5.500
1/6.500
1/7.500
1/7.500
1/9.000
1/9.000
1/13.000
1/13.000
1/16.000
Compressor nominal current 5 A 6,6 3,7 3,7 4,5 4,5 5,4 5,4 5,7 5,7 7,0 7,5 7,5 15 15 15,9 15,9 19,6
Compressor starting current 6 A 33,0 32,0 32,0 40,0 40,0 46,0 46,0 51,5 51,5 54,0 65,5 65,5 101 101 111 111 118
Sound levels (see Test room pattern)
Lw radiated casing only (LS) dB(A) 51 54 54 53 53 53 53 54 54 55 55 55 57 55 70 70 72
Lw radiated casing only (MS) dB(A) 54 56 56 54 54 56 56 56 56 59 59 59 60 59 69 69 69
Lw radiated casing only (HS) dB(A) 58 57 57 57 57 58 58 58 58 63 63 63 63 62 68 68 70
Weight
Weight of the unit (approx.) kg 85 100 112 115 115 120 133 133 135 140 144 149 150 253 255 259 280
Dimensions
Length mm 900 1.050 1.050 1.050 1.050 1.050 1.250 1.250 1.250 1.250 1.250 1.250 1.250 1.680 1.680 1.680 1.680
Width mm 600 600 705 705 705 705 705 705 705 705 705 705 705 955 955 955 955
Height mm 439 460 460 460 460 460 513 513 513 513 513 583 513 770 770 770 770
NewNew
NewNew
NewNew
New
(*) Unit suspended at 1 meter from ground.(**) 1,5 meter long acoustic duct.
| Rooftop 176
Rooftop
HAN 13-31 kW 12,1-30,5 kW R410A ScrollPage 178
Rooftair 31,8-48,7 kW 33,5-51,8 kW R410A ScrollPage 180
SysAer 48,1-219,1 kW 50,7-214,4 kW R410A EC MotorPage 182
ErP20182018
Non ERP compliant
ErP20182021
2021Ready.
Minimum ηsh to be Ecodesign compliant
Minimum ηsc to be Ecodesign compliant
EcodesignAir to Air Rooftop
ErP2018
COMMISSION REGULATION (EU) No2016/2281
100
110
120
130
140
150
2015 2016 2017 2018 2019 2020 2021 2022
ηsc / ηsh
138
115Jan.
2018
125Jan.
2021
117
Jan. 2021
years
Rooftop |
ROOF
TOP
177
Product Family Cooling Capacity Nominal airflow
Static pressure
Acoustic Power
Size (LxHxW - mm)
HAN
HAN 13 13,0 kW 2.640
m3/h 100 Pa 74 dB(A)
1.345 x 905 x 1.320
HAN 15 14,5 kW 2.940
m3/h 170 Pa 75 dB(A)
1.345 x 905 x 1.320
HAN 17 16,8 kW 3.190
m3/h 160 Pa 75 dB(A)
1.345 x 905 x 1.320
HAN 19 18,9 kW 3.860
m3/h 210 Pa 78 dB(A)
1.345 x 905 x 1.320
HAN 25 25,4 kW 4.780
m3/h 240 Pa 82,4 dB(A)
1.445 x 1.320 x 1.420
HAN 31 31,0 kW 5.530
m3/h 250Pa 82,7 dB(A)
1.445 x 1.320 x 1.420
Roof
tair
RTL/RTH 30 32,7 kW 5.500
m3/h 250 Pa 83 dB(A)
2.484 x1.450 x 1.877
RTL/RTH 40 43,1 kW 7.650
m3/h 250 Pa 85 dB(A)
2.484 x1.450 x 1.877
RTL/RTH 50 48,7 kW 9.200
m3/h 250 Pa 88 dB(A)
2.484 x1.450 x 1.877
SysA
er
SR.H.EC 55 48,1 kW 9.700
m3/h 220 Pa 81.5 dB(A)
3.250 x 1.800 x 2.030
SR.H.EC 65 61,0 kW 11.500
m3/h 220 Pa 85 dB(A)
3.250 x 1.800 x 2.030
SR.H.EC 80 76,7 kW 14.300
m3/h 225 Pa 82 dB(A)
3.250 x 1.800 x 2.030
SR.H.EC 95 92,3 kW 17.500
m3/h 240 Pa 83 dB(A)
3.740 x 2.110 x 2.285
SR.H.EC 105 107,8 kW 19.200
m3/h 240 Pa 85,4 dB(A)
3.740 x 2.110 x 2.285
SR.H.EC 120 116,3 kW 21.500
m3/h 240 Pa 87,4 dB(A)
3.740 x 2.110 x 2.285
SR.H.EC 140 137,9 kW 25.500
m3/h 240 Pa 91,3 dB(A)
3.740 x 2.110 x 2.285
SR.H.EC 160 160,1 kW 28.000
m3/h 240 Pa 90,5 dB(A)
5.505 x 2.110 x 2.285
SR.H.EC 190 191,2 kW 30.000
m3/h 240 Pa 91,5 dB(A)
5.505 x 2.110 x 2.285
SR.H.EC 210 212,6 kW 32.000
m3/h 240 Pa 93,7 dB(A)
5.505 x 2.110 x 2.285
Selection guide Rooftop
| Rooftop 178
Cooling modeTemperature before inner coil (wet bulb) °C from +12 to +26Outdoor temperature °C from -10 to +46Heating modeTemperature before inner coil (dry bulb) °C from +10 to +27Outdoor temperature °C from -10 to +18
Rooftop unitsCooling and heatingHAN
Technical features Cooling Capacity from 13 to 31 kW Heating Capacity from 12,1 to 30,5 kW Sizes: 6
Product Advantages Refrigerant: R410A A coaxial heat exchanger robust in presence of load Weather resistant casing with external panels and drain pan
coated with powder-based epoxy paint colour RAL 7040 Base rail with forklift slots to facilitate transportation and
handling. Technical compartment independent from airstreams allowing
service works to be performed without disturbing the unit operation
High efficiency scroll compressor with crankcase heater Condenser coils with hydrophilic coated fins to improve
removal of water droplets during defrost cycles Standard microprocessor-based control by CAC controller
Main options and accessories Air filter Electrical heater Kit remote control With/without low ambient option
13-31 kW R410A
12,1-30,5 kW Scroll
Operating limits
Non ERP compliant
Rooftop |
ROOF
TOP
179
Performance HAN 13 HAN 15 HAN 17 HAN 19 HAN 25 HAN 31Total cooling capacity1 kW 13,0 14,5 16,8 18,9 25,4 31,0Effective power input in cooling mode1 kW 4,5 4,9 6,1 6,5 8,3 10,0EER total1 2,88 2,95 2,8 2,9 2,95 3,1Total heating capacity1 kW 12,1 14,2 15,8 19,0 24,2 30,5Effective power input in heating mode1 kW 4,3 4,6 5,7 6,0 8,8 9,5COP1 2,8 3,1 2,7 3,1 2,8 3,2Electrical power supplySupply voltage V/Ph/Hz 400V/3~N/50HzMaximum operating intensity A 16 17 20 21 29 30Total starting intensity A 70 69 79 107 119 126RefrigerantType R410ANumber of refrigeration circuits 1 1 1 1 1 1CompressorsType ScrollNumber 1 1 1 1 1 1Power reduction stages % 0-100%Inner coilType Copper tubes & aluminum finsNumber of rows 3 3 3 4 4 4Front surface m2 0,57 0,57 0,57 0,57 0,94 0,94Inner fan
Type Centrifugal / Direct Centrifugal / Belt - variable pitch pulley
Number 1 1 1 1 1 1Air flow rate Nominal m3/h 2.640 2.940 3.190 3.860 4.780 5.530Motor power kW 0,6 0,75 0,75 1,1 1,1 1,5Outer coilType Copper tubes & aluminum finsNumber of rows 2 2 2 3 3 3Front surface m² 1,16 1,16 1,16 1,16 2,14 2,14Outer fanType PropellerNumber 1 1 1 1 1 1Diameter mm 610 610 610 610 710 710Air flow rate Nominal m3/h 9000 9000 9000 9000 12000 12000Motor power kW 0,49 0,49 0,49 0,49 0,90 0,90Acoustic dataSound power level (configuration A) dB(A) 78,2 79,3 79,3 82,6 85,6 86,4Sound power level (configuration B) * dB(A) 74,0 75,0 75,0 78,0 82,4 82,7Dimensions and WeightLength mm 1.345 1.345 1.345 1.345 1.445 1.445Width mm 1.320 1.320 1.320 1.320 1.420 1.420Height mm 905 905 905 905 1.320 1.320Weight kg 219 223 223 243 320 343
1 Following EN14511, including fan correction.* Nominal airflow - High speed fan - Without air filter.
Technical features
| Rooftop 180
Cooling modeTemperature before inner coil (wet bulb) °C from +12 to +26Outdoor temperature °C from -10 to +46Heating modeTemperature before inner coil (dry bulb) °C from +10 to +27Outdoor temperature °C from -10 to +18
Rooftop units Cooling and heating Rooftair - RTH/RTL
Technical features Cooling Capacity from 31,8 to 48,7 kW Heating Capacity from 33,5 to 51,8 kW 3 sizes 2 Versions : RTH (cooling and heating), RTL (Cooling only)
Product Advantages Refrigerant: R410A Airflow range: from 5.500 to 9.200 m³/h Insulation: 25 mm Glasswool Refrigeration circuit: cooling only or heat pump version
designed to satisfy comfort and commercial applications with scroll compressors for higher efficiency with better resistance to liquid return and less vibration
Crankcase heater on each compressor to eliminate refrigerant migration and improve start up in winter
Refrigerant brazing, fittings, and indoor coil headers are assembled in one technical compartment to ease service without disturbing unit operation Weatherproof technical compartment independent from the
airflow with a natural ventilation of the electrical board to stop overheating in summer. All electric cables and wires are protected
Main options and accessories Aeraulic configurations Control options Double skin insulation Stainless steel drain pan Electrical heater or hot water coil Indoor / outdoor coil Epoxy or copper-copper fins Filters (G4 / G4+F6 / G4+F7) Low ambient kit Anti vibration mount Moisture eliminator on fresh air Softstarter Coil guards Main blower Epoxy Air pressure switch Clogged filter Smoke sensor Remote room sensor Roof curb
31,8-48,7 kW R410A
33,5-51,8 kW Scroll
ErP20182018
Operating limits
Rooftop |
ROOF
TOP
181
Performances - RTL (cooling only) RT 30 RT 40 RT 50Nominal refrigeration power 1 kW 32,7 43,1 48,7Absorbed nominal power 1 kW 11,40 13,80 15,80EER total 1 2,87 3,12 3,08Energy efficiency class (EER) 1 B A APdesignC 2 3 kW 32,7 43,1 48,7SEER 2 3 3,17 3,43 3,37ηsc
2 3 124 134 132Performances - RTH (reversible) Nominal refrigeration power 1 kW 31,8 41,9 47,2Absorbed nominal power 1 kW 11,4 13,8 15,7EER total 1 2,8 3,0 3,0Energy efficiency class (EER) 1 C B BPdesignC 2 3 kW 31,8 41,9 47,2SEER 2 3 3,1 3,3 3,3ηsc
2 3 120 130 128Nominal heating power 1 kW 33,5 44,3 51,8Absorbed nominal power 1 kW 10,2 12,2 14,3COP 1 3,3 3,6 3,6Energy efficiency class (COP) 1 B A APdesignH 2 3 kW 30,0 40,0 49,0SCOP 2 3 3,0 3,1 3,1ηsh
2 3 116 120 119Electrical power supplySupply voltage 400V - 3ph + N - 50HzMaximum operating intensity A 42 46 57Max. Start intensity A 104 132 179RefrigerantType R410ANumber of refrigeration circuits 1CompressorsType ScrollNumber 2Power reduction stages % 0-50-100Inner coilType Copper tubes & aluminum finsNumber of rows 3 3 3Front surface m² 1,17 1,60 1,60Inner fanType Forward curved centrifugalNumber 1Air flow rate Nominal m3/h 5.500 7.650 9.200Motor power kW 1,5 1,5 2,5Outer coilType Copper tubes & aluminium finsNumber of rows 2 2 2Front surface m² 1,92 3,00 3,00Outer fanType PropellerNumber 2 2 2Diameter mm 610 610 610Air flow rate Nominal m3/h 16.000 16.000 16.000Motor power kW 1,40 1,40 1,40Acoustic dataPower level (lwo) dB(A) 83 85 88Dimensions and WeightLength mm 2.484 2.484 2.484Width mm 1.877 1.877 1.877Height mm 1.450 1.450 1.450Weight (without option) kg 600 650 700
Technical features
1 Following EN 14511 2018.2 Following EN 14825 2017. 3 Following COMMISSION REGULATION (EU) No2016/2281 for comfort application chillers.
| Rooftop 182
Rooftop units Cooling and heatingSysAer - SR.H / SR.L
Technical features
Cooling capacity from 48,1 to 219,1 kW Heating capacity from 50,7 to 214,4 kW Casings: 3 Sizes: 10 2 Versions: H (Cooling and Heating) or L (Cooling only)
Product Advantages Refrigerant: R410A Energy class A Ecodesign step 2 ready High efficiency heat exchanger 3 different energy recovery systems (RECO, TRECO or FRECO) All seasons kit Outdoor coil protection grid 2 independent circuits & frigorific insulated box Many air inlet/outlet configurations Double skin as a standard AC/EC Plug Fans for supply and extract air Removable drain pan Leak detection according to BREEAM standard Advanced control system Easy installation & maintenance Thought for transportation (every size fits in a container)
Main options and accessories
Aeraulic configurations All seasons kit EC plug fans Gas burner Sides, Top or Bottom supply/return air 2 filter stages (G4+F7/F9 flat type) High pressure fans Hot water coil or Electric Heater 2 Dampers mixing section / Freecooling /
IAQ (indoor air quality control) Food Refrigeration Heat Recovery
(FRECO energy recovery system) Return fan & 3 Dampers
(RECO energy recovery system) Return fan & 3 Dampers & Heat Recovery
(TRECO energy recovery system)
48,1-219,1 kW R410A
50,7-214,4 kW EC fans
Energy recovery systems
FRECO - Food refrigeration energy RECOveryIn supermarkets, FRECO technology allows our rooftop units to recover the heat generated out from the condensers of the cooling systems.
Additionnal heating capacity
Mixed air T° = 20°C +60%Mixed air T° = 0°C +130%
Water +30% Glycol 45/40°C
RECO - Standard energy RECOvery (3 Dampers)Energy recovery on the exhaust air
TRECO - Thermodynamic energy RECOvery (3 Dampers)Active energy recovery between the exhaust air and the fresh air using dedicated thermodynamic system
Pc EER Ph COP
3 dampers + RECO 30% fresh air +1% +2% +7% +4%
3 dampers + RECO 60% fresh air +2% +4% +14% +8%
Pc EER Ph COP
3 dampers + TRECO 20% fresh air +21% 0% +20% +3%
3 dampers + TRECO 60% fresh air +20% -2% +21% +4%
According to EUROVENT
According to EUROVENT
ErP20182021
2021Ready.
Cooling modeTemperature before inner coil (wet bulb) °C from +12 to +26Outdoor temperature °C from -10 to +50Heating modeTemperature before inner coil (dry bulb) °C from +10 to +27Outdoor temperature °C from -10 to +18
Operating limits
Rooftop |
ROOF
TOP
183
Technical featuresPerformances - SR.L.EC (cooling only) SR55.EC SR65.EC SR80.EC SR95.EC SR105.EC SR120.EC SR140.EC SR160.EC SR190.EC SR210.ECVentilationNominal refrigeration power 1 kW 49,57 62,81 78,99 95,13 111,08 119,87 142,09 164,98 197,06 219,12Absorbed nominal power 1 kW 15,81 19,46 23,23 30,66 33,56 37,10 47,09 51,19 60,61 71,54EER total /Energy efficiency class (EER) 1 3,13/A 3,23/A 3,40/A 3,10/A 3,31/A 3,23/A 3,02/A 3,22/A 3,25/A 3,06/APdesignC 2 3 kW 49,57 62,81 78,99 95,13 111,08 119,87 142,09 164,98 197,06 219,12SEER 2 3 3,57 3,58 3,74 3,54 3,66 3,57 3,52 3,91 3,94 3,71ηsc
2 3 140 140 147 138 143 140 138 154 154 145Performances - SR.H.EC (reversible) Nominal refrigeration power 1 kW 48,12 60,95 76,67 92,34 107,81 116,34 137,88 160,10 191,21 212,60Absorbed nominal power 1 kW 15,81 19,46 23,23 30,66 33,56 37,10 45,69 51,19 60,61 70,47EER total /Energy efficiency class (EER) 1 3,04/A 3,13/A 3,30/A 3,01/A 3,21/A 3,14/A 3,02/A 3,13/A 3,15/A 3,02/APdesignC 2 3 kW 48,12 60,95 76,67 92,34 107,81 116,34 137,88 160,10 191,21 212,60SEER 2 3 3,53 3,52 3,63 3,52 3,55 3,52 3,52 3,80 3,82 3,65ηsc
2 3 138,15 137,98 142,23 137,81 139,17 137,83 137,67 148,92 149,82 143,15Nominal heating power 1 kW 50,65 59,65 76,63 90,66 106,95 117,10 148,70 157,90 187,31 214,37Absorbed nominal power 1 kW 14,81 17,49 21,77 26,59 30,38 34,14 42,85 46,17 54,29 62,68COP 1 / Energy efficiency class (COP) 1 3,42/A 3,41/A 3,52/A 3,41/A 3,52/A 3,43/A 3,47/A 3,42/A 3,45/A 3,42/APdesignH 2 3 kW 48,00 58,00 67,00 85,00 100,00 112,00 145,00 155,00 180,00 210,00SCOP 2 3 3,20 3,22 3,22 3,23 3,22 3,21 3,20 3,19 3,23 3,19ηsh 2 3 125,00 126,00 126,00 126,00 126,00 125,00 125,00 125,00 126,00 125,00Electrical power supplySupply voltage 400V / 3~ +N / 50HzMaximum operating intensity A 46,30 57,60 74,60 83,80 89,80 103,00 123,00 157,80 161,80 178,60Start intensity (without soft starter) A 156,10 175,00 184,60 225,80 276,80 290,00 347,00 266,80 303,80 365,60Start intensity (with soft starter) A 69,96 85,68 113,60 125,40 139,20 152,40 185,40 198,10 203,40 228,00Refrigerant Type R410ANumber of refrigeration circuits 2 2 2 2 2 2 2 2 2 2 CompressorsType ScrollNumber 2 2 2 2 2 2 2 4 4 4Mounting type Single Tandem
Power reduction stages % 0/50/100 0/50/100 0/50/100 0/50/100 0/50/100 0/50/100 0/50/100 0/25/50/75/100
0/25/50/75/100
0/25/50/75/100
Crankcase heater W 2 x 70 2 x 70 2 x 70 2 x 70 2 x 70 2 x 70 2 x 120 4 x 70 4 x 70 2 x 70 - 2 x 120
Inner coilType Copper tubes & aluminum finsNumber of rows 3 3 4 3 4 4 4 4 6 6Front surface m² 1,50 1,80 2,25 2,25 3,24 3,24 3,24 3,24 3,24 3,24Inner fanType Backward curved centrifugalNumber 4 1 1 2 2 2 2 2 2 2 2
Air flow rate 4
Minimum m3/h 7.760 9.200 11.440 14.000 15.600 17.200 20.400 24.000 25.400 27.500Nominal m3/h 9.700 11.500 14.300 17.500 19.500 21.500 25.500 28.000 30.000 32.000Maximum m3/h 11.640 13.800 17.160 21.000 23.400 25.800 30.600 33.600 36.000 38.400
Motor power kW 3,5 5,7 5,8 7 7 11,4 11,4 13,5 13,5 13,5Outer coilType Copper tubes & aluminum finsNumber 2 2 3 2 3 3 3 2 3 3Front surface m² 0,76 1,01 1,01 1,50 1,50 1,50 1,50 2,70 2,70 2,70Outer fanType AxialNumber 2 2 2 2 2 2 2 4 4 4Diameter mm 630 710 710 800 800 800 800 800 800 800Air flow rate Nominal m3/h 9.800 13.000 13.000 20.000 20.000 20.000 20.000 15.500 15.500 20.500Motor power kW 0,62 0,94 0,94 1,65 1,65 1,65 1,65 0,84 0,84 1,65Acoustic dataRadiated power level db(A) 81,5 85 82 83 85,4 87,4 91,3 90,5 91,5 93,7Dimensions and Weight
LengthTotal mm 3.250 3.250 3.250 3.740 3.740 3.740 3.740 5.505 5.505 5.505Floor mm 2.895 2.895 2.895 3.295 3.295 3.295 3.295 5.050 5.050 5.050
Width mm 2.030 2.030 2.030 2.285 2.285 2.285 2.285 2.285 2.285 2.285Height mm 1.800 1.800 1.800 2.110 2.110 2.110 2.110 2.110 2.110 2.110Weight (without option) kg 1.085 1.155 1.225 1.470 1.685 1.805 1.855 2.350 2.555 2.705
1 Following EN 14511 2018.2 Following EN 14825 2017.
Sysoft AC - For a precise selection and more technical information : www.sysoftac.com
3 Following COMMISSION REGULATION (EU) No2016/2281 for comfort application chillers.4 EC standard fans.
| Close Control 184
Close control units
SysTemp P Direct expansion 7-100 kWChilled water 10-160 kWPage 185
SysTemp G Direct expansion 50-100 kWChilled water 43-170 kWPage 188
TMC 5-116 kWPage 192
SysTemp R Direct expansion 8-30 kWChilled water 20-35 kWPage 190
Close Control |
CLOS
E CO
NTRO
L
185
Direct Expansion and Chilled Water Close control unitsSysTemp P
7-100 kW Direct Expansion 10-160 kW Chilled water
The P Series close control air conditioners have constructional and operating characteristics suitable for environments where thermal loads of a sensitive nature prevail.
Although optimised for data centers, the technical characteristics of the P series make these units suitable for various types of special applications, such as metrology laboratories, TV produc-tion studios, recording and conservation rooms for musical instru-ments, museums and archives, control rooms in power stations and railway junctions. In addition, their application proves ideal for various industrial sectors: optics, electronics, electromedical equipment, production of electrical or electronic equipment, production of musical instruments, etc.
P series air conditioners offer:
Temperature and humidity close control. A high delivered cooling capacity to footprint ratio, which
makes it easier to design the environments to be air condi-tioned.
Very high values of energy efficiency, which translate into lower CO2 emissions into the environment, and in particularly low operating costs.
High flexibility of use, thanks to the wide range of accessories which can be selected.
Technical features Very high EER (Energy Efficiency Ratio) Limited footprint Dark gray RAL 7024 metal structure Panels with thermo-acoustic insulation Electrical panel complete with control and safety devices SySmart control microprocessor with graphic display G4-class efficiency air filters with dirty filter alert Return air temperature sensor Supply air temperature sensor Electronic EC fans R410A scroll compressors Electronic expansion valves with SysDrive system Three-way control valves Unit shutdown system for the presence of fire RS485 Modbus® RTU slave card
Available accessories
Direct expansion: Brushless DC compressors with inverter regulation Power supply line for remote condenser Power supply line with speed regulator for remote condenser Condensing regulation with 0-10V signal for remote condenser
with EC fans LT Kit for operation with low temperature outside air with remote
condenser Oversize liquid receiver Check valves on the supply and liquid pipes Water-cooled condenser Water-cooled condenser with a condensing temperature control
valve HT Kit for operation at high condensing temperatures
Chilled water: Two-way control valves Inlet and outlet water temperature sensors Energy valve kit
Other accessories: Heating accessories Humidification accessories Mechanical and structural accessories Electrical accessories Regulation accessories
| Close Control 186
Air Conditioners with downflow air supply
ST UPU: Chilled water air conditioners with downflow air supply
Notes:(1) Performance refers to: R410A refrigerant; con-
densing temperature 45°C; incoming air 24°C-45%Rh; water 7/12°C; external static pressure 30 Pa. The declared performance does not take into account the heat generated by fans, which must be added to the system thermal load.
(2) EER (Energy Efficiency Ratio) = total cooling capac-ity / compressors power consumption + fans pow-er consumption (air cooled condensers excluded).
(3) Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010.
Standard version with top air intake and downflow air supply, with stand for raised floors.
Version with top air intake and front air supply through air distribution plenum with adjustable grilles.
Version with top air intake and front air supply through front panel.
ST UPU 10 20 30 50 80 110 160 220PerformanceTotal cooling capacity 1 kW 10,1 18,2 32,4 43,6 66,8 80,2 121,9 160,3
Sensible cooling capacity kW 9,4 15,7 29,8 38,1 62,1 72,0 109,7 144,0EER 2 30,6 26,0 25,1 20,8 25,0 23,1 22,2 23,1
Air flow rate m3/h 2.200 3.200 7.400 8.200 15.400 17.000 26.000 34.000Noise level 3 dB(A) 51 57 59 63 61 62 65 65
Dimensions and weightsWidth mm 750 750 860 860 1.750 1.750 2.640 3.495
Depth mm 601 601 880 880 880 880 880 880Height mm 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990
Net weight kg 115 160 225 240 340 360 540 700Two Sources
ST UPA 71 141 211 251 301 302 361 422 461 512 662 852 932PerformanceTotal cooling capacity 1 kW 7,8 14,8 21,4 26,4 33,2 31,1 37,9 43,7 47,9 54,7 68,2 85,9 94,2Sensible cooling capacity kW 7,5 13,6 21,4 25,7 32,0 31,1 37,9 43,7 47,4 53,0 65,2 73,0 85,4EER 2 3,68 3,34 3,30 3,25 3,08 3,24 3,42 3,36 3,50 3,35 3,15 3,20 3,58Air flow rate m3/h 2.200 3.200 7.000 7.000 8.700 8.700 14.500 14.500 14.500 14.500 17.900 17.900 20.700Noise level 3 dB(A) 51 57 57 58 62 61 60 60 60 60 63 64 62Dimensions and weightsWidth mm 750 750 860 860 1.410 1.410 1.750 1.750 1.750 1.750 2.300 2.300 2.640Depth mm 601 601 880 880 880 880 880 880 880 880 880 880 880Height mm 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990Net weight kg 150 205 260 285 360 385 440 485 450 500 640 660 860Free CoolingTwo Sources
ST UPA: Direct expansion air conditioners with downflow air supply and aircooled or watercooled condensers
Close Control |
CLOS
E CO
NTRO
L
187
ST OPA 71 141 211 251 301 302 361 422 461 512 662 852 932PerformanceTotal cooling capacity 1 kW 7,8 14,8 21,4 26,4 33,2 31,1 37,9 43,7 47,9 54,7 68,2 85,9 94,2Sensible cooling capacity kW 7,5 13,6 21,4 25,7 32,0 31,1 37,9 43,7 47,4 53,0 65,2 73,0 85,4EER 2 3,77 3,46 3,37 3,29 3,18 3,35 3,50 3,42 3,57 3,40 3,26 3,29 3,63Air flow rate m3/h 2.200 3.200 7.000 7.000 8.700 8.700 14.500 14.500 14.500 14.500 17.900 17.900 20.700Noise level 3 dB(A) 51 57 56 57 60 59 59 59 59 59 62 62 61Dimensions and weightsWidth mm 750 750 860 860 1.410 1.410 1.750 1.750 1.750 1.750 2.300 2.300 2.640
Depth mm 601 601 880 880 880 880 880 880 880 880 880 880 880Height mm 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990 1.990
Net weight kg 150 205 260 285 360 385 440 485 450 500 640 660 860Free CoolingTwo Sources
Air Conditioners with upnflow air supply
ST OPA: Direct expansion air conditioners with upflow air supply and aircooled or watercooled condensers
ST OPU: Chilled water air conditioners with upflow air supplyNotes:(1) Performance refers to: R410A refrigerant; con-
densing temperature 45°C; incoming air 24°C-45%Rh; water 7/12°C; external static pressure 30 Pa. The declared performance does not take into account the heat generated by fans, which must be added to the system thermal load.
(2) EER (Energy Efficiency Ratio) = total cooling capac-ity / compressors power consumption + fans power consumption (air cooled condensers ex-cluded).
(3) Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010.
ST OPU 10 20 30 50 80 110 160 220PerformanceTotal cooling capacity 1 kW 10,1 18,2 32,4 43,6 66,8 80,2 121,9 160,3
Sensible cooling capacity kW 9,4 15,7 29,8 38,1 62,1 72,0 109,7 144,0EER 2 36,0 33,0 28,0 24,4 27,8 28,0 27,1 28,0
Air flow rate m3/h 2200 3200 7400 8200 15400 17000 26000 34000Noise level 3 dB(A) 51 57 58 61 60 61 63 64
Dimensions and weightsWidth mm 750 750 860 860 1750 1750 2640 3495
Depth mm 601 601 880 880 880 880 880 880Height mm 1990 1990 1990 1990 1990 1990 1990 1990
Net weight kg 115 160 225 240 340 360 540 700Two Sources
Standard version with front air intake and upflow air supply.
Version with front air intake and sup-ply, through air distribution plenum with adjustable grilles.
Version with air intake from the bottom, stand for raised floor, blind front panel and upflow air supply.
| Close Control 188
Direct Expansion and Chilled Water Close control unitsSysTemp G
50-100 kW Direct Expansion 43-170 kW Chilled water
G series close control air conditioners have constructional and operating characteristics suitable for meeting the design criteria of the latest generation data centers.When designing air conditioning systems for large data centers, the need for electrical cable housing and the enormous air volumes re-quired to cool down the servers have made it essential to increase the height of raised floors up to the current 550/1,000-millimeter level. A large space below the air conditioner for the installation of an adjustable stand has thus created. It was therefore decided to use this large space to house supply fans.Without increasing the footprint of the machine, and only exploit-ing space where it is provided, great advantages have been obtained:
With the same air conditioner footprint, it has been possible to increase the front section of the coil by about 40-50% by reducing the pressure drop on the air side, and thus the fan energy consumption.
Increasing the size of the air filters installed upstream of the cold coil allows a significant reduction in load losses and replacement frequency for maintenance.
Increased efficiency of the fans which, installed in the stand, expel treated air horizontally and completely unobstructed.
Technical feature Very high EER (Energy Efficiency Ratio) Limited footprint Dark gray RAL 7024 metal structure Panels with thermo-acoustic insulation Electrical panel complete with control and safety devices SySmart control microprocessor with graphic display G4-class efficiency air filters with dirty filter alert Return air temperature sensor Supply air temperature sensor Electronic EC fans R410A scroll compressors Electronic expansion valves with SysDrive system Two-way control valves Unit shutdown system for the presence of fire RS485 Modbus® RTU slave card
Available accessories
Direct expansion: Power supply line for remote condenser Power supply line with speed regulator for remote condenser Condensing regulation with 0-10V signal for remote condenser
with EC fans LT Kit for operation with low temperature outside air with
remote condenser Oversize liquid receiver Check valves on the supply and liquid pipes Water-cooled condenser Water-cooled condenser with a condensing temperature control
valve
Chilled water: Two-way control valves Inlet and outlet water temperature sensors HT Kit for operation at high condensing temperatures
Other accessories: Heating accessories Humidification accessories Mechanical and structural accessories Electrical accessories Regulation accessories
Close Control |
CLOS
E CO
NTRO
L
189
Air Conditioners with downflow air supply
ST UGA: Direct expansion air conditioners with downflow air supply and aircooled or water cooled condensers
ST UGA 461 612 932PerformanceTotal cooling capacity 1 kW 49,3 62,2 103,8
Sensible cooling capacity 1 kW 48,2 54,8 103,8EER 2 3,87 3,25 4,07Air flow rate m3/h 9.500 10.000 19.000Noise level 3 dB(A) 57 58 59Dimensions and weightsWidth mm 1.490 1.490 2.390Depth mm 921 921 921Height mm 1.990+550Net weight kg 500 500 720
Notes:1 Performance refers to: R410A refrigerant; condensing temperature 45°C; incoming air 32°C-30%Rh;water 15/20°C; external static pressure 30 Pa, ventilated plenum,
height 1000 mm. The declared performance does not take into account the heat generated by fans, which must be added to the system thermal load.2 EER (Energy Efficiency Ratio) = total cooling capacity / compressors power consumption + fans power consumption (air cooled condensers excluded).3 Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010.
Standard version for data center perimetral installation: The height of the raised floor must be at least 550 mm.
Standard version for data center perimetral installation with raised floor height less than 550 mm. In this case the stand, having a fixed height of 550 mm provided with side clos-ing panels, must be installed above the floor. However, please make sure that the ceiling height allows good air intake.
Version for installation outside the data cent-er, with no raised floor and rear supply line. In this case the stand, having a fixed height of 550 mm, is provided with side closing panels and rear supply grilles. The installation of a plenum with a rear air intake system is op-tional, in the absence of a duct system.
ST UGU: Chilled water air conditioners with downflow air supply
ST UGU 70 150 230 300PerformanceTotal cooling capacity 1 kW 43,3 85,1 124,4 170,2
Sensible cooling capacity 1 kW 43,3 85,1 124,4 170,2EER 2 31,12 32,48 34,65 39,13Air flow rate m3/h 9.500 19.000 28.500 38.000Noise level 3 dB(A) 57 59 61 60Dimensions and weightsWidth mm 1.320 2.220 3.120 4.020Depth mm 921 921 921 921Height mm 1.990+550Net weight kg 400 620 930 1.250
| Close Control 190
Direct Expansion and Chilled Water Close control unitsSysTemp R
8-30 kW Direct Expansion 20-35 kW Chilled water
R series close control air conditioners are built and sized in such a way that they can be installed alongside data center racks In air conditioning systems for large data centers, the adoption of the following design concepts has in fact become an established custom: The racks containing servers are increasingly positioned ac-
cording to the Hot Aisle and Cold Aisle layout. Air temperatures are allowed to rise up to 30-35°C in the hot
aisle and 20-25°C in the cold one, with very low humidity (never above 30%).
Server performance is increasingly on the rise, while server sizes are increasingly reduced. As a result, many more servers can be installed in a rack, so some of these racks can be elimi-nated as they are empty. At the same time, heat dissipation increases, thereby requiring more power from air conditioners. R series air conditioners are designed and built so as to fit into this plant layout perfectly. As a matter of fact:
They exploit the space left free from racks and allow cold air to be distributed as close as possible to servers, that is, where heat is generated.
They feature rear intake from the hot aisle and front supply to the cold aisle with a horizontal flow. The horizontal flow reduces internal pressure drop, with a consequent reduction in the power draw of the fan.
Technical features Very high EER (Energy Efficiency Ratio) Limited footprint Dark gray RAL 7024 metal structure Panels with thermo-acoustic insulation Front and rear accessibility for easy maintenance Cooling, electric and water top/bottom connections Electrical panel complete with control and safety devices SySmart control microprocessor with graphic display G4-class efficiency air filters with dirty filter alert Return air temperature sensor Supply air temperature sensor Electronic EC fans Brushless DC compressors with R410A inverter regulation Electronic expansion valves with SysDrive system Three-way control valves Unit shutdown system for the presence of fire RS485 Modbus® RTU slave car
Available accessories
Direct expansion: Brushless DC compressors with inverter regulation Power supply line for remote condenser Power supply line with speed regulator for remote condenser Condensing regulation with 0-10V signal for remote condenser
with EC fans LT kit for operation with low temperature outside air with
remote condenser Oversize liquid receiver Check valves on the supply and liquid pipes Water-cooled condenser Water-cooled condenser with a condensing temperature control
valve HT Kit for operation at high condensing temperatures
Chilled water: Three-way control valves Inlet and outlet water temperature sensors Energy valve kit
Other accessories: Heating accessories Humidification accessories Mechanical and structural accessories Electrical accessories Regulation accessories
Close Control |
CLOS
E CO
NTRO
L
191
Air Conditioners with horizontal air supply
ST HRA: Direct expansion air conditioners with horizontal
ST HRA 121 231 361PerformanceTotal cooling capacity 1 kW 8,6 19,6 31,4
Sensible cooling capacity kW 8,5 16,4 25,7EER2 2,92 3,19 3,32
Air flow rate m3/h 3.000 6.000 6.800Noise level 3 dB(A) 50 52 54
Dimensions and weightsWidth mm 300 600 600
Depth mm 1.200 1.222 1.222Height mm 1.970 1.985 1.985
Net weight kg 190 215 215Free Cooling
Notes:1 Performance refers to: R410A refrigerant; condensing temperature 45°C; incoming air 30°C-30%Rh; water 14/20°C; external static pressure 30 Pa. The declared
performance does not take into account the heat generated by fans, which must be added to the system thermal load.2 EER (Energy Efficiency Ratio) = total cooling capacity / compressors power consumption + fans power consumption (air cooled condensers excluded).3 Sound levels at a 2 m distance, in a free field, as per UNI EN ISO 3744:2010.
Version for "in row" installation with front and side air supply
ST HRU 20 40PerformanceTotal cooling capacity 1 kW 21,2 31,6
Sensible cooling capacity kW 21,2 31,6EER2 16,0 25,7
Air flow rate m3/h 6.000 9.000Noise level 3 dB(A) 56 61
Dimensions and weightsWidth mm 300 600
Depth mm 1.200 1.222Height mm 1.970 1.985
Net weight kg 120 190Two Sources
ST HRU: Chilled water air conditioners with horizontal supply
| Close Control 192
Remote condensers and dry coolers for Close control unitsTMC
Technical features
Versions for horizontal and vertical installation and with V-shaped structure.
Turbocoil heat exchangers made of hot dipped galvanized metal sheet with copper tubes expanded into aluminium fins
Casing made of galvanised steel, powder coated Epoxy-Polyester RAL 9003 resistant to corrosion
High-efficiency, low-consumption motors, statically and dynamically balanced, with permanently greased bear-ings, in-built overheat protection and integrated protec-tion grilles
Valid for units with direct expansion circuit only.
Available air-cooled condenser and dry cooler accessories
Latest generation EC fans for high-energy savings, reduced noise levels and better regulation of the number
of revolutions Fins coated with ALUPAINT for better aluminium corrosion
protection. (ACC only) Configuration with multiple circuits or sub cooling circuits Vibration-damping kits Electrical panel complete with control, safety devices and
fans wiring The Whisperer silencers Dry and Spray system Water Spray System.
5-116 kW Remote condensers
11-120 kW Dry coolers
Direct Expansion |
DIRE
CT E
XPAN
SION
193
Direct Expansion
XAR 12,3-55 kW R407CPage 194
XAO 8-45,7 kW R407CPage 196
Product Range Capacity Flow rate Sound pressure Size (LxHxW) mm
Air Cooled Models
X 1200 12,3 kW 2.000
m3/h 51dB(A) 890 x 1.540 x 430
X 1900 16,2 kW 3.200
m3/h 56 dB(A) 1.000 x 1.735 x 500
X 2450 19,8 kW 4.500
m3/h 59 dB(A) 1.300 x 1.840 x 600
X 3250 29,0 kW 5.800
m3/h 65 dB(A) 1.530 x 1.830 x 600
X 4650 38,9 kW 9.000
m3/h 61 dB(A) 1.715 x 1.970 x 790
X 6450 55 kW 12.000
m3/h 69 dB(A) 1.980 x 1.970 x 790
Water Cooled Models
CX 25 8 kW 1.500
m3/h 52 dB(A) 800 x 1.280 x 407
X 1200 AO 15 kW 2.000
m3/h 51 dB(A) 890 x 1.540 x 430
X 1900 AO 18,0 kW 3.200
m3/h 55 dB(A) 1.000 x 1.735 x 500
X 2450 AO 23,0 kW 4.500
m3/h 58 dB(A) 1.300 x 1.840 x 600
X 3250 AO 32,4 kW 5.800
m3/h 64 dB(A) 1.530 x 1.830 x 600
X 4650 AO 45,7 kW 9.000
m3/h 60 dB(A) 1.715 x 1.970 x 790
Selection guide Direct Expansion
| Direct Expansion 194
Vertical air cabinetCooling only XAR
Technical features Cooling Capacity: from 12,3 to 55 kW Refrigerant: R407C Size: 6
Configurations Split system
Product Advantages Adjustable base frame Easy installation and maintenance Split system with outdoor condenser fan unit Treated air distribution to premise by plenum or duct network Adjustable available static pressure Temperature control by thermostat Electrical, refrigeration and thermal protection devices
Accessories and options Air distribution duct frame ”All seasons” system (Cooling mode operation) down to
outdoor temperature of -10°C) Electric heater or Hot water coil Fresh air intake Front air distribution plenum High ventilation Outdoor unit - UC Pipe link Remote fault reporting Room thermostat and ON/OFF switch Set of female valves (Mandatory accessories) Total rear intake duct frame Without neutral
Operating limits (for standard unit)
12,3-55 kW
R407C
FACTORY
Minimum temperature
Indoor temperature °CThi 13Tsi 17
Outdoor temperatureWithout TTS °C Tse +19With TTS* °C Tse -10
Maximum temperature
Indoor temperature °CThi 22Tsi 32
Outdoor temperature °C Tse 47
* With “All seasons kit” optionThi : Wet bulb indoor temperatureTsi : Dry bulb indoor temperatureTse : Dry bulb outdoor temperature
UC - Outdoor unit(accessory)
Direct Expansion |
DIRE
CT E
XPAN
SION
195
Technical features
XAR 1200 1900 2450 3250 4650 6450Cooling capacity 1
Nominal cooling capacity W 12.300 16.200 19.800 29.000 38.900 55.000Nominal cooling capacity BTU/hr 42.000 55.300 67.600 99.000 137.000 189.200Air flowNominal treated air m3/h 2.000 3.200 4.500 5.800 9.000 12.000Mini./maxi. treated air m3/h 1.500/2.500 2.500/3.800 3.600/5.400 4.600/7.000 7.200/10.800 9.500/14.500Nominal fresh air (with accessory) m3/h 180 285 420 500 1.300 1.650Available static pressureStandard/Maxi equipment daPa 0/13 0/21 0/20 0/25 0/23 0/29Power input ventilationMini/Maxi equipment W 260/510 380/580 500/1.100 700/1.800 1.600/2.400 3.100/4600Sound pressure indoor unit 2
Normal speed dB(A) 51 56 59 65 61 69Power supplyNominal voltage 400V/3N~/50HzVoltage range V 360/440 360/440 360/440 360/440 360/440 360/440Total power input 1 W 4.808 8.076 8.900 12.630 16.950 24.000
DimensionsDimensions (LxWxH) mm 890x430x1540 1.000x500x1.735 1.300x600x1.840 1.530x600x1.830 1.715x790x1.970 1.980x790x1.970
1 International standard ISO 51.51 conditions.27°C/19°C wet bulb - Outside air : 35°C/24°C wet bulb.Wasted water : inlet + 15°C - Recycled water inlet/outlet : 30°C/35°C.2 Total sound pressure dB(A) (4m) under nominal conditions in a room of 1000m3 (reverberation 0.83s).
Example of outdoor condensing unit (UC) UC 34 UC 54 UC 104 UC 104Compatible with / number of necessary outdoor unit(s) X1200.AR / 1 X1900.AR / 1 X2450.AR / 1
X4650.AR / 2X3250.AR / 1 X6450.AR / 2
Number 1 1 1 2Air flow m3/h 8.600 7.600 14.000 14.000Power input W 530 611 1.222 1.222Sound pressure dB(A) 52 53 56 56
DimensionsDimensions (LxWxH) mm 885x825x840 885x825x840 1.546x885x840 1.546x885x840
| Direct Expansion 196
Vertical water cabinetCooling onlyXAO
Technical features Cooling Capacity: from 8 to 45,7 kW Refrigerant: R407C Size: 6
Configurations Monobloc system
Product Advantages Easy installation and maintenance
Monobloc system Public or recycled water operation Treated air distribution to premise by plenum or duct network Adjustable available static pressure Temperature control by thermostat Electrical, refrigeration and thermal protection devices
Accessories and options Air distribution duct frame Electric heater or Hot water coil Fresh air intake Front air distribution plenum High ventilation ON/OFF switch and room thermostat Pressostatic valve Remote fault reporting Sum heating resistance Total rear intake duct frame Without neutral
Operating limits (for standard unit)
8,0-45,7 kW
R407CFACTORY
Minimum temperature Maximum temperature
Air temperature at evaporator inletBH (°C) 15 23
BS (°C) 21 32
Water temperature (°C) 10 34
BS : Dry bulb temperature (°C)BH : Wet bulb temperature (°C)
Direct Expansion |
DIRE
CT E
XPAN
SION
197
Technical features
XAO X 1200 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AOCooling capacity 1
Nominal cooling capacity W 15.005 18.000 23.000 32.400 45.700Nominal cooling capacity BTU/hr 51.200 61.400 78.500 110.550 157.200Air flowNominal treated air m3/h 2.000 3.200 4.500 5.800 9.000Mini./maxi. treated air m3/h 1.500/2.500 2.500/3.800 3.600/5.400 4.600/7.000 7.200/10.800Nominal fresh air (with accessory) m3/h 180 285 420 500 1.300Available static pressureStandard/Maxi equipment daPa 0/13 0/21 0/20 0/25 0/23Power input ventilationMini/Maxi equipment W 260/510 380/580 500/1.100 700/1.800 1.600/2.400Sound pressure 2
Normal speed dB(A) 51 55 58 64 60Power supplyNominal voltage 400V/3N~/50HzVoltage range V 360/440 360/440 360/440 360/440 360/440Total power input 1 W 4.843 6.616 7.100 9.800 13.900Water circuit 1
Wasted water - Flow L/h 914 950 1.000 1.700 2.800Wasted water - Pressure drop kPa 37 30 22 35 18Recycled water - Flow L/h 3.161 3.050 3.500 5.780 8.300Recycled water - Pressure drop kPa 80 65 45 40 56DimensionsDimensions (LxWxH) mm 890x430x1.540 1.000x500x1.735 1.300x600x1.840 1.530x600x1.830 1.715x790x1.970
1 International standard ISO 51.51 conditions.27°C/19°C wet bulb - Outside air : 35°C/24°C wet bulb.Wasted water : inlet + 15°C - Recycled water inlet/outlet : 30°C/35°C.2 Total sound pressure dB(A) (4m) under nominal conditions in a room of 1000m3 (reverberation 0.83s).
CX CX 25Cooling capacityNominal cooling capacity (Water : 18 °C - Air : 19 °C Wet Bulb) W 8.000Nominal cooling capacity (Water : 18 °C - Air : 19 °C Wet Bulb) BTU/hr 27.300Air flowNominal treated air m3/h 1.500Power input W 245Electrical dataPower supply 230V / 1~ / 50 HZ 400V / 3 N ~ / 50 HZCooling + ventilationNominal input A 12,28 5,28Input Max. A 14,85 6,38aM fuse A 16 8ASE/VDE fuse A 16 10Electric heater + ventilationNominal input A 26 9,6Input Max. A 31 11,61aM fuse A 32 12ASE/VDE fuse A 35 16WeightNet weight kg 125
| HPT Hydrokit198
HPT Hydrokit
Technical features 48 sizes Structurally equipped of tank, expansion tank,
pump, filter, control valves, electrical box 6 volumes of the storage tank from 300 to
2.500 litres 14 different pumps models Two versions:
with one or two water pumps Anti freezer protection
3
2
1
11
6 8
4
7
9
10
12
5
13
1 Tank
2 Circulating pump
3 Expansion tank
4 Pressure gauge
5 On/Off valves
6 Safety valve
7 Automatic air vent valve
8 Air vent valve
9 Make-up valve
10 Automatic make-up unit
11 Electrical board
12 Non-return valve (only on version with 2 pumps)
13 Water storage drain
HPT Hydrokit |
HPT H
YDRO
KIT
199
Pumpmodel
Tank volume Wsb1 Wsb2 F.L.I.F.L.A. F.L.A.
Q MIn H Max Q Max H Min Ve(400/3/50) (230/3/50)
lt kg kg kW A A m3/h кPа m3/h кPа lt
A300 186 216 1,1 2,5 4,3 6 188 24 83 25500 208 238 1,1 2,5 4,3 6 188 24 83 25
В300 188 220 1,5 3,2 5,5 6 220 24 122 25500 210 242 1,5 3,2 5,5 6 220 24 122 25
С300 188 220 1,5 3,4 5,9 10 170 45 61 25500 210 242 1,5 3,4 5,9 10 170 45 61 25
D300 191 225 2,2 4,8 8,3 10 230 45 112 25500 213 247 2,2 4,8 8,3 10 230 45 112 25
E300 194 231 3 5,6 9,7 10 230 45 112 25500 215 253 3 5,6 9,7 10 248 45 137 25
F
750 341 428 3 6,2 10,8 30 191 72 103 251.000 364 455 3 6,2 10,8 30 191 72 103 251.500 513 586 3 6,2 10,8 30 191 72 103 2 x 252.500 565 638 3 6,2 10,8 30 191 72 103 3 x 25
G
750 370 485 5,5 11 — 30 308 84 145 251.000 392 512 5,5 11 — 30 308 84 145 251.500 565 696 5,5 11 — 30 308 84 145 2 x 252.500 613 732 5,5 11 — 30 308 84 145 3 x 25
H
750 373 493 5,5 11 — 48 210 108 137 251.000 396 520 5,5 11 — 48 210 108 137 251.500 569 696 5,5 11 — 48 210 108 137 2 x 252.500 617 740 5,5 11 — 48 210 108 137 3 x 25
I
750 377 501 7,5 14,6 — 48 260 120 180 251.000 400 528 7,5 14,6 — 48 260 120 180 251.500 569 696 7,5 14,6 — 48 260 120 180 2 x 252.500 617 740 7,5 14,6 — 48 260 120 180 3 x 25
L
750 377 501 11 21,2 — 48 342 120 249 251.000 400 528 11 21,2 — 48 342 120 249 251.500 569 696 11 21,2 — 48 342 120 249 2 x 252.500 617 740 11 21,2 — 48 342 120 249 3 x 25
M1.500 628 814 15 28,6 — 48 405 138 288 2 x 252.500 680 866 15 28,6 — 48 405 138 288 3 x 25
О1.500 634 826 15 28,6 — 84 330 180 220 2 x 252.500 686 878 15 28,6 — 84 330 180 220 3 x 25
P1.500 646 850 18,5 34,2 — 84 385 216 220 2 x 252.500 698 902 18,5 34,2 — 84 385 216 220 3 x 25
Q1.500 660 878 22 40,3 — 84 475 180 325 2 x 252.500 712 930 22 40,3 — 84 475 180 325 3 x 25
F.L.I. - Full load power.F.L.A. - Full load current.Q Min - Minimum flow. Q Max - Maximum flow.H Min - Minimum pressure.H Max - Maximum pressure.Wsb1 - Shipping weight with pump.Wsb2 - Shipping weight with two pumps.Ve - Expansion tank capacity.PVe - Tank pressure.PS - Maximum operating pressure.T Min - Minimum water temperature.
PVe PS T Minbar bar °C1,5 3 -10
Technical features
Legend:
www.systemair.com
Syst
emai
r · Ju
ne 2
018
· AIR
CO
NDI
TIO
NIN
G CA
TALO
GUE
GB •
E340
15As
par
t of o
ur o
ngoi
ng p
rodu
ct im
prov
emen
t pro
gram
me,
our
pro
duct
s ar
e su
bjec
t to
chan
ge w
ithou
t prio
r not
ice.
Non
con
trac
tual
pho
tos.
Systemair srlVia XXV Aprile, 2920825 Barlassina (MB) Italy
Tel. +39 0362 680 1Fax +39 0362 680 693
Systemair AC SASRoute de Verneuil 27570 Tillières-sur-Avre France
Tel. +33 02 32 60 61 00Fax +33 02 32 32 55 13