Page 1
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Aggregate Testing - 2017 Test List
Aggregate Mechanical and Physical Testing
No. 4-8-02-1994 Appendix B
Drying Shrinkage
BS 812: Part 124
UKAS
300mm Shear Box
Apparent Bulk Density of Filler
Horizontal Permeability Inc. PSD
Alkali Reactivity - Mortar bar method (16 day)
Polished Stone Value (PSV) EN 1097-8
UKAS
BS 1377: Part 7 &SHW Volume 1 Clause 639 -
Granular MaterialCohesive Material (per loading)
BS EN 1097-3
Aggregate Abrasion Value (AAV)Aggregate Crushing Value (ACV)
Petrographic Examination Fine
BS812 - 104BS812 - 104
EN 933-5
Aggregate Impact Value - Dry (AIV)Aggregate Impact Value - Soaked (AIV)
Petrographic Examination Coarse Petrographic Examination Fine
Granular Material
ITP 1 (Based on BS812-104)
Alkali Silica Reactivity (Concrete Prism Method) BS 812: Part 123
Angle of Internal Friction & Adhesion
AccreditationDescription Method
ASTM C1260
SHW Volume 1 Clause 636 - Angle of Internal Friction & Adhesion300mm Shear Box
BS EN 1097-8: Annex ABS 812: Part 110
Constituent MaterialsDicalcium Silicate Disintegration
Compaction Fraction
Drying Shrinkage
BS EN 933-11
Iron Disintegration EN 1744-1
including Annex B
UKAS
extra over per day
Frost Susceptibility
Bond Work IndexBulk Density & Void (Loose & Compacted)
with Reinforcing Elements SuppliedCohesive Material (per loading)extra over per day
EPRI Report CS3612:FGD
BS 812: Part 112BS 812: Part 112
BS 1377: Part 7 &
UKASUKAS
EN 1097-3
UKAS
UKASUKAS
UKAS
UKAS
UKAS
EN 1097-1: Annex A
UKAS
Water Industries Spec.
Micro Deval (MDRB)
Laboratory Dry Density & Optimum Water Content
Micro Deval (Wet or Dry)
UKAS
EN 1097-2: Annex A
Flakiness Index
EN 1097-1 UKAS
UKAS
UKAS
DTP HA 41/90 UKAS
UKAS
EN 933-1
ITP 1 (Based on BS812-104)
UKAS
EN 933-10 UKASParticle Size Distribution (Air-Jet Sieving)
Petrographic Examination Coarse
in Coarse AggregatePercentage of Shells in Coarse Aggregate EN 933-7 UKAS
UKASPercentage Crushed & Broken Surfaces
Resistance to Thermal Shock EN 1367-5Resistance to Freezing & Thawing EN 1367-1 UKAS
Petrographic Examination EN 932-3
Petrographic Examination (ASR) ASTM C289-94
Sand Equivalent EN 933-8 UKASShape Index EN 933-4 UKASShale Content BGSC Report CR/03/281N
Moisture Content BS 812: Part 109Particle Density & Water Absorption EN 1097-6 UKASParticle Density of Filler EN 1097-7 UKAS
EN 13450Particle Length of Rail Ballast
Particle Size Distribution (Sieving Method)Particle Size Distribution (Sedimentation) BS 812: Part 103
Loss on Ignition
Los Angeles Coefficient (LA)
Los Angeles Coefficient (LARB)
Horizontal Permeability Inc. PSD & OMC/MDD
EN 933-3
EN 1097-2
EN 13286-4
EN 1744-1
EN 1744-1ASTM C157EN 1367-4
Immediate Bearing Index (IBI) BS EN 13286-47
Sonnenbrand Test (Visual Examination) BS EN 1367-3
UKAS
UKAS
Page 2
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Aggregate Testing - 2017 Test List
Aggregate Mechanical and Physical Testing (Continued…)
Hydraulically bound mixtures
Aggregate Chemical Testing
Magnesium Sulphate
Methylene Blue EN 933-9
Preparation of Eluates by Leaching Aggregatesincludes Ph and ConductivitySodium Sulphate SoundnessTotal Sulphur ContentTotal Neutralising ValueWater Soluble ChlorideWater Soluble SulphateWater Soluble Sulphate
Salt for Spreading on Highways
Cube Compressive strength Age up to 28 Days @ 40°CCube Compressive strength Age up to 28 Days BS EN 13286-41
BS EN 13286-41
Magnesium Sulphate (DWFS Specifications) DWFS (012, 013 & 049) - 1st Fraction UKAS
Cohesion EN ATS 97-1-2016 Annex C
Accelerated Swelling test BS EN 13286-49
Description
Method Accreditation
Voids Ratio EN ATS 97-1-2016 Annex F
EN 1097-5 UKASWet Attrition BS 812: 1951
Thermal Expansion (Manufacture Prisms)
Ten Per Cent Fines Value (Dry)
Sonnenbrand Test Inc. Strength Testing (AIV)Sonnenbrand Test Inc. Strength Testing (LA)
BS EN 1367-3
BS 812: Part 111 UKAS
Sonnenbrand Test (Mass Loss)
Thermal Expansion on 150mm Lump RockTen Per Cent Fines Value (Soaked) BS 812: Part 111 UKAS
Voids of Dry Compacted FillerWater Solubility EN 1744-1 UKASWater Content
UKAS
BS EN 1367-3BS EN 1367-3
BS 812-118
EN 1744-1BS 6463-102
EN 1744-1 UKAS
BS 1438 UKASEN 1744-1 UKAS
Microbial Activity Index TRL Report 54Organic Contaminators (by mortar method) EN 1744-1
Rate per additional fraction
In-House Method SO71 Based on CUR 33UKAS
UKAS
Methylene Blue (Bentonite Content)
EN 1367-2 including Annex B UKAS
EN 1367-2 Annex C UKASRate per additional fraction
Lightweight Contaminators EN 1744-1 UKAS
Magnesium Sulphate
Fulvo Acid Content EN 1744-1 UKASHumus Content EN 1744-1 UKAS
UKASUKAS
UKASCalcium Carbonate EquivalentCalcium Carbonate Reference
Carbonate Content - Volumetric Method BS 7755
BS EN 196-2BS EN 196-2
Acid Soluble Sulphides
Description Method Accreditation
Acid Soluble Chloride
BS 812: Part 119
BS EN 1744-1: Clause 13 UKAS
UKASUKAS
BS EN 1744-5: Volhard Method
Acid Soluble Sulphate
Slag Expansion BRE In-House MethodThermal Resistivity / Conductivity on Cement Bound Sand ASTM D5334
BS EN 1744-1: Clause 12
Description
UKAS
Description Method Accreditation
BS EN 13286-40
Acid Soluble Material
Soluble Sulphate Content BS 3247 UKAS
Grading of Salt BS 3247 UKASMoisture Content BS 3247
Mixing and Preparation (per mixture) BS EN 13286 UKASDirect tensile strength
Method Accreditation
Coefficient of linear expansion SHW CL 871
Chloride Content BS 3247 UKAS
Matter Insoluble in Water BS 3247 UKAS
Modulus of Elasticity (per specimen) BS EN 13286-43
EN 1744-3
UKAS
UKAS
Page 3
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Bituminous Testing - 2017 Test List
BS EN 12697 Series of Tests
Binder Drainage (Schellenberg Method)Binder Drainage (Basket Method)
Saturating Ageing Tensile Test BS EN 12697-45
Bituminous DesignsMethod Accreditation
Marshall Test (Stability & Flow)(loads from 1 to 25 kN)
per specimenBS EN 12697-35 UKAS
UKAS
Amount of Foreign Matter
BS EN 12697-35
UKAS
BS EN 12697-25
Hot Sand Test BS EN 12697-37 UKAS
SMA Mix Design (5 points)
Resistance to Fatigue
Indirect Tensile Strength (loads from 1 to 25 kN) per
specimenBS EN 12697-23 UKAS
Wheel Tracking (per 200mmø Core)BS EN 12697-22
BS EN 12697-3UKAS
UKAS
UKAS
BS EN 12697-32
Binder & Grading - Binder directly determined, using
bottle rotation machine, bucket centrifuge type 1 and
volume calculation
Air Voids
Bulk Density
BS EN 12697-11: Static
Binder Recovery (Rotary Evaporation)
UKAS
BS EN 12697-5 UKAS
BS EN 12697-3BS EN 1426
Laboratory Mixing per 2KG
Binder Recovery (Rotary Evaporation) / Penetration /
Softening PointUKAS
UKAS
Binder & Grading - Binder determined by difference,
using bottle rotation machine and pressure filter
BS EN 12697-1: Procedure 1 &UKASBS EN 12697-2
BS EN 12697-2
BS EN 12697-24
Resistance to de-icing fluids
AccreditationDescription Method
BS EN 1427
Maximum Density - Volumetric Procedure A
BS EN 12697-1: Procedure 1 UKAS
UKAS
Cyclic Compression - Method A
Indirect Tensile Stiffness Modulus (IT-CY) (loads from 0 to
10 kN)
Stone Mastic Asphalt Mix Design does not include
aggregate testing or additional bituminous testing.
BS EN 12697-41
Defence Works for Airfields Specification 049
BS EN 12697-43
BS 13108-5 & PD6691 Annex D UKAS
Water Sensitivity - Method A Water Sensitivity - Method B BS EN 12697-12
Resistance to Fuel
BS EN 12697-42
Permeability of Bitumen Specimen (Vertical)
Percentage Refusal Density: Per CoreBS EN 12697-9
BS EN 12697-11: Rolling Bottle
Determination of particle loss of porous asphalt BS EN 12697-17
BS 594987:2010- Annex H
Defence Works for Airfields Specification 012 UKAS
UKAS
BS EN 12697-18
UKAS
Procedure A -DryProcedure B - Dry
HRA Surface Course Design ProtocolHRA Asphalt Mix Design (loads 1 to 25 kN) does not
include aggregate testing or additional bituminous
Defence Works for Airfields Specification 013
Description
Procedure C - Sealed Specimen
BS EN 12697-8
BS EN 12697-26 Annex C UKAS
Set of 10 Specimens
UKASAffinity between aggregate & bitumen
Procedure D -Dimensions
UKAS
BS EN 12697-6:Procedure A - Dry
Permeability of Bitumen Specimen (Horizontal)BS EN 12697-19 UKAS
Procedure B - SSD
BS EN 12697-12 UKAS
UKAS
Specimen preparation by roller compactor BS EN 12697-33 UKAS
Marshall Asphalt Mix Design (loads 1 to 25 kN) does not
include aggregate testing or additional bituminous
DWFS Specification 049
Page 4
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Bituminous Testing - 2017 Test List
Other Bituminous Tests
Water & Binder Content of Bituminous Emulsion BS 434: Part 1 1984 Appendix F
Delta Ring & Ball BS EN 13179-1 UKAS
BBA HAPAS Appendix A.2
TPH / PAH / Phenol & Leachate
Indirect Fatigue Tensile test DD ABF: 1995
Photographs and description of asphalt Inc. PAK Marker
(per core)
Photographs and description of asphalt cores
Viscosity
Binder & Grading - Thermoplastic RoadBS 3262: Part 1: 1989
BS EN 12697-36 + In-House Method(per core)
BS EN 12697-36 + In-House Method
Bitumen Number of added Filler
Markings Inc. Glass Bead Content
Penetration Test (Bitumen)BS EN 1427: 2000
AccreditationDescription
BS EN 1426: 2000 UKASUKAS
BS 598: Part 110: 1998
BS EN 13179-2
UKAS
BS434: Part 1: 1984
Documented in house method UKAS
Water Sensitivity - Thin Surfacing Layer
BBA HAPAS Appendix A.5 2013
Softening Point
Resistance to permanent deformation
Method
Wheel Tracking (per 200mmø Core)
Resistance to permanent deformation (VRLAT) :Per Core
UKAS
Appendix G
UKAS
Sensitivity to fuelSensitivity to fuel
Based on BS DD 226: 1996(RLAT): Per Core
Torque Bond Strength
BBA HAPAS Appendix A.5 2011 UKAS
Documented in house method Based on TRL PA PA3287/97 and BS DD 226:
1996UKAS
BBA HAPAS Appendix A.3
Page 5
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Concrete Testing - 2017 Test List
BS 1881 Tests
BS 1881-201: BRE IP 6/81
BS EN 12390 Tests
Miscellaneous Concrete/Mortars
Method of testing Cement & Water used in Concrete
EN 196-3
BS EN 772 Masonry Tests
Strength (for water used in concrete) EN 1008/BS EN 196-1
BS EN 1008Setting Times (for water used in concrete)
Chemical Analysis
Initial Setting Time; Initial and Final Setting Time
EN 196-3
Original Mix Proportions (Screed/Mortar Mixes)
of Mortar (delivered)
Flexural & Compressive Strength
Compressive strength of Cylinders BS EN 12390-3 UKAS
EN 1008/BS EN 196-3
UKAS
BS EN 12504-1
UKAS
Documented In House Method
Accreditation
BS 4551: Part 2
EN 196-1EN 196-2
Accreditation
UKAS
UKAS
UKAS
Concrete Cubes - (delivered) per cube
Secant Modulus of Elasticity in Compression
Method
BS EN 12390-7
Accreditation
UKAS
BS EN 12390-13
Chemical Testing of water found in concrete
AccreditationDescription Method
BS EN 12390-2 and
Sulphates in Concrete
Static Modulus of Elasticity
BS EN 13892-2
Trial Mixes
Soundness
Depth of Carbonation
Cement Type (OPC, SRC or HA)
Strength
Linear Coefficient of Thermal Expansion (Concrete or
Aggregate Prism)
Description
Examining cores
BS 1881: Part 125BS 1881-121
Air Content - water column method BS EN 12350-7: Clause 4
Compressive Strength including coring
BS EN 12390-5
Flexural & Compressive Strength
Depth of penetration of water under pressure
In-house Test Method
BS EN 12504-1
UKAS
BS 1881-124
Cement Content / Original Mix Proportions
UKAS
Description Method
Resistivity BS 1881-201 UKAS
Compressive Strength -
Flexural Strength of Beams
BS 1881: Part 124Chloride Content - Titriometric method BS 1881: Part 124 UKASChloride Content - Potentiometric method BS 1881: Part 124
UKAS
Method
UKAS
Compressive Strength concrete core delivered
Description
BS EN 12504-1
of Screed (delivered)BS EN 1015-11
BS EN 12390-3
Tensile splitting strength BS EN 12390-6 UKASBS EN 12390-8
Hardened Density of Concrete
Description Method Accreditation
Compressive Strength:Air dried for 14 days BS EN 772: Clause 7.3.2
BS EN 772: Clause 7.3.5
Dried in oven for 24 hours BS EN 772: Clause 7.3.2
Oven dried @ 105oC BS EN 772: Clause 7.3.3
Oven dried @ 70oC BS EN 772: Clause 7.3.3Conditioned to 6% moisture content BS EN 772: Clause 7.3.4Conditioning by Immersion
Cellular/Hollow Units:
Net and Gross Density:
Thermal Properties (Solid Blocks Only) BS EN 1745
BS EN 772-16Solid Units:
Determination of Flatness: BS EN 772-20BS EN 772-14Moisture Movement:
Hollow/Cellular Units: BS EN 772-13Solid Units: BS EN 772-13Determination of Dimension:
Including Final Set
Setting Time :- Initial
Water Absorption by Capillary
BS EN 772-16
BS EN 722-11
Page 6
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Rock and Slate Testing - 2017 Test List
ISRM Rock Tests
CIRIA Rock Tests
SLATE Tests
Rock Armour Tests
Miscellaneous Rock Tests
(set of 10) 1:1 Ratio
Sulphur Dioxide Exposure
Slip Resistance using Pendulum Tester BS EN 14231
BS EN 12326-2Unpolished Slip Resistance Value
Flexural Strength under concentrated load BS EN 12372
BS EN 14157
BS EN 12371
Abrasion Resistance
BS EN 1936
Accreditation
UKAS
Point Load Index Set of 10
Water Absorption at Atmospheric pressure BS EN 13755
Frost Resistance (48 cycles)
Description Method
ISRM GuidelinesDensity ISRM Guidelines
UKAS
Real Density, Apparent Density and total Open Porosity
Brazil Tensile Strength
Porosity
Point Load Test 1 Test Only ISRM Guidelines
Deformability in Uniaxial Compression ISRM Guidelines
CIRIA Specification
CIRIA Specification
Failure Load in BendingPetrographic
Calcium Carbonate Content BS EN 12326-2
Dimensional Tolerances
BS EN 12326-2
Drop Test Breakage Index
AccreditationDescription Method
Freeze Thaw
ISRM Guidelines
Description Method
Slates with less than 20% CaCo3
CIRIA Rock manual section 3.8 Box 3.20
Wet Dynamic Crushing ValueMill Abrasion Index
Fracture Toughness CIRIA Specification
ISRM Guidelines
Accreditation
CIRIA Specification
UKAS
Unconfined Compressive Strength of
UKAS
Thermal Cycle BS EN 12326-2 UKAS
BS EN 12326-2BS EN 12326-2 UKASBS EN 12362-2
(set of 10) 1:1 Ratio - includes coring
Cerchar Abrasitivity In House Method
Accreditation
Method
BS EN 1926
Description
BS EN 13383
Accreditation
Water Absorption
Youngs Modulus ISRM Guidelines
Description
Determination of Uniaxial Compressive Strength BS EN 1926
Deformability in UCS ASTM Guidelines
Slake Durability ISRM Guidelines
Length to Thickness RatioParticle Density and Water AbsorptionDetermination of Uniaxial Compressive Strength
BS EN 13383
Rock Cores 2.5:1 Ratio
Resistance to Breakage Mass Distribution BS EN 13383
ISRM Guidelines
BS EN 1341
Non-Carbonate carbon Content BS EN 12326-2
Method
Page 7
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Soil Testing - 2017 Test List
BS 1377 Soil Mechanical and Physical Testing
BS 1377: Part 5: 1990
BS 1377 Soil Chemical Testing
Calcium Carbonate Content
Accreditation
Methylene Blue Value on BES In-house Method SO71: July 2009
Dry Method (Top and Bottom) UKAS
BS 1377: Part 3:1990 Clause 10 BS 1377-3: 1990
BS 1377: Part 3: 1990: Clause 3
UKASTRRL Contractor Report 54
Pulverisation BS EN 13286-48
UKAS
Saturated Moisture Content
Consolidated Drained/Undrained Triaxial
(Multistage Same Price)
BS 1377-8
BS 1377: Part 9: 1990 Clause 2.4 UKAS
AccreditationDescription Method
extra over per dayShear Vane
Method
Shear Box Interface Testing (1mm/min)ASTM D5321
extra over per day
Shear Box Interface Testing (Slow test per loading)
Resistivity
BS 1377: Part 3: 1990
PH Value BS 1377: Part 3: 1990Organic Matter Content
UKAS
UKAS
UKAS
UKAS
UKAS
UKAS
Extra charge per day for each day
Microbial Index
K.H.Head Manual of SoilFalling Head Permeability
ASTM D5321
Calculated as reciprocal of Resistivity
(3 specimens) Per specimen - up to 1 day
BS 1377: Part 2: Clause 3.3
Description
UKASUKAS
UKAS
UKAS
Accelerated Permeability in a Triaxial Cell: Environment Agency R & DUp to 4 days Technical Report P1-398/TR/2 UKAS
BS 1377: Part 2: 1990
Dispersion
UKASUp to four (4) days
UKASParticle Size Distribution (Washing and Sieving)
over four days
Laboratory Testing, Volume 2
UKAS
Open Container Method
Plasticity Index BS 1377: Part 2: 1990
Undrained Shear StrengthUndrained Triaxial (3x U38)
UKAS
Chloride Ion Content BS 1377: Part 3: 1990
Particle Size Distribution (Sedimentation) BS 1377: Part 2: 1990
BS 1377: Part 6: 1990
Shear Box - 60mm or 100mm BS 1377: Part 7:1990: Clause 4
Triaxial Permeability:
BS 1377: Part 2: 1990
BS 1377: Part 2: 1990
Electrical Conductivity of Soil
Redox Potential
BS 1377: Part 2: 1990Plastic Limit
Particle Size Distribution (Dry Sieving)
BS 1377: Part 7: 1990
Sub Clause 4:
BS 1377: Part 7: 1990
Extra Charge per day after 4 days
Particle Density - Small Pyknometer BS 1377: Part 2: 1990
Moisture Content
Pin Hole Method
UKASParticle Density - Gas Jar BS 1377: Part 2: 1990 UKAS
OMC/MDD (2.5kg, 4.5kg or
BS 1377: Part 5:1990: Clause 3
Minimum Density
UKASMCV/Moisture Content Relationship BS 1377: Part 4: 1990 Test 5.5
UKAS
MCV Single Point BS 1377: Part 4: 1990 Test 5.4
BS 1377: Part 4: Clause 7: 1990
UKASMaximum Density BS 1377: Part 4: 1990
Core Cutter Density
Wet Method Inc. Swelling
California Bearing Ratio (Laboratory)
Constant Head Permeability
Compaction Vibrating Hammer (@ NMC) BS 1377: Part 4: 1990 UKAS
Extra Charge per day after 5 days
UKAS
Dry Method (Top) UKAS
Liquid Limit - Cone Penetrometer
UKAS
BS 1377: Part 2: 1990
Initial Consumption of lime BS 1924-2
Multistage Triaxial BS 1377: Part 7: 1990 Clause 9BS 1377: Part 4: 1990
Oedometer Consolidation (up to 5 days)
BS 1377: Part 4:1990Vibrating Hammer Method
Page 8
Celtest Company Limited. Registered in Wales and England 1533370. Vat No. 352-5034-81
Trefelin Bangor Gwynedd LL57 4LH T +44 (0)1248 355269 F +44 (0)1248 351563 E postmaster celtest.com W www.celtest.com@
0494
Soil Testing - 2017 Test List
BS 1377 Soil Chemical Testing (Continued…)
BS 1377: Part 3: 1990
Topsoil Analysis Topsoil AnalysisTopsoil Analysis (Contamination Assessment)Topsoil Analysis (Contamination Assessment)
Calculation only - Test 2 & 4 mustbe carried out
Miscellaneous Tests
PCM
Chromium VI
WAC (10 day t/a) BS EN 12457 Part 3
WAC including interpretation (10 day t/a) BS EN 12457 Part 3WAC (6 day t/a) BS EN 12457 Part 3WAC including interpretation (6 day t/a) BS EN 12457 Part 3
Rates are NET and subject to VAT
Description Method Accreditation
Alkali ContentAngle of Repose (Slope Stability) In-House
Acid Soluble Sulphate
Total Petroleum Hydrocarbons (TPH'S)
Transportable Moisture Limit IMSBC CDE 2012Total Silica In-house
XRD including Pyrite
BRE Special Digest
XRD
Banded Total Petroleum Hydrocarbons (TPH'S)
Polyaromatic Hydrocarbons (Total PAH's)Speciated PAH
Total Organic Carbon
Tar Content of Asphalt Arisings (TPH C10-C40 & PAH
Speciated)In -house Standard
Sulphide and Hydrogen Sulphide Standard Text Book
GC/MS ScanHeavy Metals Suite
Full ICRCL Contamination SuiteFull ICRCL Contamination Suiteincluding EA Leachate
CLEA Suite
Electrical Conductivity of Water BS EN 27889: 1993Dangerous Substances
Calorific ValueChemical Oxides Analysis (XRF)
Asbestos Identification
Asbestos QuantificationGravimetric
Oxidisable Sulphides
Total Reduced Sulphur TRRL Report 447 Test 3
TRRL Report 447 Test 2TRRL Report 447 Test 1
Total Potential Sulphate
Water Soluble Sulphate
TRRL Report 447 Test 4
BS 1377: Part 3: 1990Gravimetric Method
Total Sulphur
Sulphate content of soil and ground water
BS 3882 (including interpretation)
BS 1377
Sulphate content of soil and ground water BS 1377: Part 3: 1990Ion exchange Method
UKAS
In House Method
AccreditationDescription Method
BS 3882BS 3882 (including interpretation)
ResistivityWenner Probe
Suspended SolidsBS 3882