(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2000 No Conditioner or Vane Upstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart. 2 SECTION METER TUBES SIZE UL (44D) DL (4.5D +24”) 2 7'-10" 3'-0" 3 11'-4" 3'-6" 4 14'-13" 4'-0" 6 22'-4" 4'-6" 8 29’-5” 5'-0" 10 36’-12” 6'-0" 12 43’-13” 6'-6" 14 48’-3” 7'-0" 16 55’-0” 8'-0" 18 62’-0” 8'-6" 20 69’-0” 9'-6" 24 83’-0” 10'-8" 19 – Tube Bundle LSV Upstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart. 2 SECTION METER TUBES W/ VANES SIZE UPSTREAM DOWNSTREAM VANE LOCATION VL 2* 5'-0" 3'-0" 3 7'-5" 4'-0" 3'-8" 4 9'-9" 4'-0" 4'-10" 6 14'-8" 5'-0" 7'-1" 8 19'-8" 5'-0" 9'-6" 10 24'-10" 6'-0" 12'-0" 12** 29'-8" 7'-0" 13'-5-1/2" / 15'- 2-1/2"
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2000
No Conditioner or VaneUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.
19 – Tube Bundle LSVUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
2 section tubes 3 Section tubes
3 SECTION METER TUBES WITH FLANGED TYPE VANESSIZE UPSTEAM
LENGTHTOTAL
INLET SPOOL including vane flange(s), 3 gaskets and 1/2" spacer
Note: Minimum Length Upstream for TOL/HC is 36” from Profiler or Vane inlet.
(MIN) STANDARD METER TUBE LENGTHS PER AGA/API 14.3 - 2002
No Conditioner or VaneUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 44D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.
19 – Tube Bundle LSVUpstream lengths (UL) are based on the largest expected published I.D. for a given size and rounded up to nearest inch at 29D. Downstream lengths exceed the minimum recommended minimum length. All downstream lengths (DL) are complete with (2) each 1/2" and (1) 3/4" threadolet or coupling, spaced 6” apart.
*2" vanes are not available at this time, in any schedule. See Profiler for 2" sizes**12" and larger have 2 setscrews. Numbers shown are to 1st, then to 2nd setscrew
3 SECTION METER TUBES WITH FLANGED TYPE VANESSIZE UPSTEAM
LENGTHTOTAL
INLET SPOOL including vane flange(s), 3 gaskets and 1/2" spacer