www.abb.com/utilitycommunications Basic Options – 670: FE Version – 675: GbE Version – 677: 16 x Ports GbE Version Power over Ethernet Option (PoE) – P: PoE (Slot 1 & 2 need to be of „T“ Type; PS need to be of „H / Z“ type) – E: No PoE Mounting Option – R: Ports on rear side – E: Ports on front side Gigabit Ethernet (GbE) Option – CP: 2 x GbE Combo Ports – GP: 4 x GbE SFP cages – GT: 4 x 10/100/1000 BaseT Ports – GS: 2 x GbE SFP cages & 2 10/100/1000 BaseT Ports – EE: No GbE Ports (AFS670/677) Port Options – T: 2 x Ports 10/100BaseT – D: 2 x Ports FE SC, MM (8 dB) – F: 2 x Ports FE SC, SM (16 dB) – I: 2 x Ports FE SC, SM, Long haul (7-29 dB) – K: 2 x Ports FE SC, SM, extra Long haul (14-47 dB) – A: 2 x Ports FE ST, MM (8 dB) – B: 2 x Ports FE ST, SM (16 dB) – S: 2 x SFP cages – U: 2 x Ports FE MTRJ, MM (8 dB) – V: 2 x Ports FL ST, MM (9.5 dB) – M: 2 x Ports FE M12 connector – E: Slot empty Temperature Options – N: Temperature range 0°C – 60°C – P: Temperature range -40°C – 85°C – Z: Temperature range -40°C – 85°C incl. Conformal coating Power Supply Options – L: Low voltage PS (9,6–60VDC), spring clamps – H: High Voltage PS (77–320VDC, 90–265VAC), spring clamps – Y: Low Voltage PS (9,6–60VDC), connector – Z: High Voltage PS (77–320VDC, 90–265VAC), connector – E: No redundant PS Future Option – X: Default Firmware Option – Firmware release Management Ports – USB Port for CRA (Configuration Recovery Adapter) – V.24 Port for Management – 2 x Alarm Switchover Contacts (230VAC, 2A) Protection Features IEEE802.1w Rapid Spanning Tree Protocol (RSTP) IEC62439 Media Redundancy Protocol (MRP) E-MRP Enhanced MRP E-MRP Performance: Ring with < 10 Devices: Switch over time < 10ms Ring with < 100 Devices: Switch over time < 40ms Redundant coupling of several E-MRP rings is supported. Network topo- logy consisting of a main ring and subrings is also supported (up to 4 subring ports per device). Each device supports multiple protection proto- cols (e.g. E-MRP on port 1 & 2, MRP on port 3 & 4). For more details please refer to the AFS user manual. Utility grade Switch IEC61850 approved IEEE1613 approved EMC/ EMI EN61000-4-2 (ESD): 8kV contact discharge,15kV air discharge EN61000-4-3: 35Vpp/m (80–2700 MHz); 1kHz, 80% AM EN61000-4-4 (Burst): 4kV power line, 4kV signal- und data line EN61000-4-5 (Surge): power line: 2kV (line/earth),1kV (line/ line) EN61000-4-12: 2,5kV line/earth,1kV line/line (1MHz) EN61000-4-16: 30V; 50Hz continous; 300V, 50Hz 1s IEEE C37.90 HV impulse ±5 kV line/earth IEEE C37.90.1 Burst ±4 kV, damped vibr. ±2.5 kV line/earth, ±1 kV line/line IEEE C37.90.2 Electromagnetic field 80 - 1000 MHz 35 v/m (peak) IEEE C37.90.3 ESD; contact discharge ±8 kV; air discharge ±15 kV Mechanical Tests IEC60068-2-27 Shock: 15g,11ms duration,18 Shocks IEC60068-2-6 Vibration: 1mm, (2–13,2Hz), 90min.; 0,7g, (13,2–100Hz), 90min.; 3,5 mm, (3–9Hz),10 cycles, 1 octave/ min.; 1g, (9–150Hz),10 cycles,1 octave/min. Applicable Standards IEEE802.1d MAC Bridges IEEE802.1D/p Port Priority IEEE802.1D Switching, GARP, GMRP, Spanning Tree (Supported via 802.1S implementation) IEEE802.1Q-1998 Virtual Bridged Local Area Networks (VLAN Tagging, Port Based VLANs, GVRP) IEEE802.1x Port Authentication IEEE802.1AB Topology Discovery (LLDP) IEEE802.3 – 2002 Ethernet IEEE802.3ac VLAN Tagging IEEE802.3ad Link Aggregation IEEE802.3af Power over Ethernet (PoE) IEEE1588 Precision Time Protocol (PTP) Radius Centralized Password Management RMON Remote Monitoring SNMP V1/V2/V3 Simple Network Management Protocol SNTP Simple Network Time Protocol Available SFPs Normal Temperature Range 0°C – 60°C FAST SFP-MM LC: FE, MM, 1310nm, 0-8dB FAST SFP-SM LC: FE, SM, 1310nm, 0-13dB FAST SFP-LH LC: FE, SM, 1550nm, 10-29dB FAST SFP-SM+ LC: FE, SM, 1310nm, 10-29dB SFP-SX LC: GbE, MM, 850nm, 0-7.5dB SFP-LX LC: GbE, MM, 1310nm, 0-11dB SFP-LH LC: GbE, SM, 1550nm, 6-22dB SFP-LH+ LC: GbE, SM, 1550nm, 13-32dB Extended Temperature Range -40°C – 85°C FAST SFP-LH LC EEC: FE, SM, 1550nm, 10-29dB FAST SFP-MM LC EEC: FE, MM, 1310nm, 0-8dB FAST SFP-SM LC EEC: FE, SM, 1310nm, 0-13dB FAST SFP-SM+ LC EEC: FE, SM, 1310nm, 10-29dB SFP-LH LC-EEC: GbE, SM, 1550nm, 6-22dB SFP-LX LC EEC: GbE, MM, 1310nm, 0-11dB SFP-SX LC EEC: GbE, MM, 850nm, 0-7.5dB A F S 6 7 5 - E R G T T T S U D A E E E E E E N Z Z X 0 5 . 0 1 1KHA - 001 138 - SEN - 01.10 - Printed in Switzerland © ABB Switzerland Ltd, January 2010. The right to modifications or deviations due to technical progress is reserved. ABB FOX Switch (AFS) Family for utility applications AFS670 / AFS675 Overview Electrical Port Options 10/100 BaseT M12 connector Ports on rear side Ports on front side SFP cage MTRJ connector Optical Port Options SC connector ST connector For ABB internal use only!