Top Banner
AERO Sound absorbing ventilator. AEROMAT 100 Window systems Door systems Comfort systems ASSEMBLY AND OPERATING INSTRUCTIONS
12

AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

May 17, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

AERO

Sound absorbing ventilator.

AEROMAT 100

Window systems

Door systems

Comfort systems

ASSEMBLY ANDOPERATING INSTRUCTIONS

Page 2: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

2

AEROMAT 100 Installation and operating instructions

03.2020

Contents

Target group of this documentation ................................................................................................................................................ 3Correct use ...................................................................................................................................................................................... 3Safety notices .................................................................................................................................................................................. 3Installation ....................................................................................................................................................................................... 4Mains supply ................................................................................................................................................................................... 4Unit function .................................................................................................................................................................................... 5Operation ........................................................................................................................................................................................ 6Maintenance ................................................................................................................................................................................... 7Cleaning .......................................................................................................................................................................................... 7Accessories ..................................................................................................................................................................................... 9Technical specifications ................................................................................................................................................................10Dimensions ....................................................................................................................................................................................10Feedback on documentation ........................................................................................................................................................10

Page 3: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

Installation and operating instructions AEROMAT 100

03.2020 3

Target group of this documentation

This documentation is intended for use by specialists only. All work described in this document is to be performed by experienced professionals with training and practice in the installation, commissioning and maintenance of ventilation units. Safe and proper assembly of this unit is not possible without expert knowledge.

Correct use

• The AEROMAT 100 is intended for installation in the exterior windows/walls of permanent structures in accordance with our installation and design documents as well as the specifications of our assembly instructions and is only suitable for the ventilation of enclosed rooms.

• Do not use the AEROMAT 100 in environments with corrosive or explosive atmospheres (dust, vapour or gas).

• Use the AEROMAT 100 only with genuine accessories from SIEGENIA.

• Observe the safety regulations for operating electrical equipment and, if necessary, for ladders, steps and work overhead or at certain heights.

• Use the AEROMAT 100 only when it is in a technically sound condition.

• Do not modify the unit's components in any way.

• Ventilation openings must be kept free and must not be blocked by other equipment, furniture or objects.

• Please do not put any objects on top of the unit.

• In the event of a fault, only have the AEROMAT 100 repaired by experienced specialists with training and practice in the repair of ventilation units.

• Any use of this product that is not in accordance with its correct use, or any adaptation of or modification to the product and its associated components for which the express consent of SIEGENIA has not been obtained, is strictly prohibited. SIEGENIA accepts no liability whatsoever for any material losses or injury to people caused by failure to comply with this stipulation.

Safety notices

Type DK

• This unit can be used by children aged 8 and above as well as by people with physical, sensory or mental difficulties or with a lack of experience and knowledge as long as they are supervised or have been instructed in how to use the unit safely and understand the resulting risks. Children must not play with the unit. Cleaning and user maintenance must not be carried out by children without supervision.

• Electrically operated unit. Risk of fatal injury from electric shock or fire. To prevent personal injury or damage to property, always comply with the following instructions:

- Work on a 230 V AC mains power supply may only be performed by a qualified electrician.

- If the mains connection cable for the unit is damaged, it must be replaced by SIEGENIA, the company's customer service department, or similarly qualified personnel in order to prevent personal injury or damage to property.

- All-pole safety isolation is required if the customer is routing the network connection cable.

- All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regulations (e.g. VDE 0100) and any relevant country-specific requirements.

- Relevant country-specific regulations must be strictly followed for all work carried out on the voltage supply system or house wiring system.

- Should a solid object or any liquid get inside the unit, stop operation immediately and disconnect the AEROMAT 100 from the mains power supply: Check whether the AEROMAT 100 is damaged If necessary, repair work can be performed by experienced professionals

Page 4: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

4

AEROMAT 100 Installation and operating instructions

03.2020

Installation

Prerequisites for installation

• The position from which the outdoor air is drawn in must be selected in such way that any nearby emission sources have as little impact as possible on the quality of the air being drawn in.

• Installation options:Installation in glazing rebate

AEROMAT100

Installation in impost

AEROMAT100

Installation sequence

1. Carefully remove AEROMAT 100 from the packaging. We recommend placing the unit on a soft surface (e.g. cardboard or blanket) during installation.

2. Close the fan flap to prevent contamination (e.g. dust) from entering the unit during installation.

3. Install the AEROMAT 100 in its intended installation position and seal it in accordance with the installation directives applicable on site.

4. Check AEROMAT 100 for cleanliness prior to starting it up. If necessary, thoroughly clean the unit as described in our operating instructions.

Mains supply

The AEROMAT 100 Type DK is connected to the 230 V AC mains power supply using an external switch.

Exposed electrical components. Risk of fatal injury from electric shock or fire.

› Work on a 230 V AC mains power supply may only be performed by a qualified electrician.

› All work on the 230 V AC mains power supply must be carried out in compliance with the current German VDE regulations (e.g. VDE 0100) and any relevant country-specific requirements.

› Switch off or unscrew the fuses.

Important: If the AEROMAT 100 Type DK is connected directly to the 230 V AC mains power supply, a mains isolator must be installed by the customer.

PE1234

S1

PENL1

bluebrownblack

(ventilator open)

Page 5: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

Installation and operating instructions AEROMAT 100

03.2020 5

Unit function

Pressure differential operation

• The room is ventilated as the indoor and outdoor air pressures are equalised (pressure differential). As this happens, the air normally flows from outside into the room.

• The air flow into the room varies as the wind pressure changes with the weather.

Unit types

Depending on its version, the AEROMAT 100 is delivered with a left or right-hand operating lever. On the respective opposite side, there is a small screw for the pressure setting of the fan flap.

Use/Unit properties Type D Type DK

1

3

2

Pressure setting of the fan flap (Item 1)

Fan flap (Item 2)

The airflow is regulated using the operating lever.-

Electric fan flap (Item 2)The airflow is regulated via an external switch. (for possible switch types, see the "Accessories" chapter).

-

Operating lever (Item 3)

The airflow can be continuously set using the operating lever.Attention! Units with electric fan flaps cannot be operated manually via the operating lever.

( )

Pressure differential operationThe room is ventilated as the indoor and outdoor air pressures are equalised. Normally, air flows from outside into the room. Depending on the weather conditions, the wind pressure increases the air flow into the room.

Volume flow limiter (optional accessories)For limiting the air flow at changing and high differential pressure.

Rod operating device (optional accessories)We recommend to use the rod operating device starting at an installation height of 1.80 m or higher (see the "Rod operating device" and "Accessories" chapters). Do not use any inappropriate auxiliary materials to operate the unit.

-

Sound absorption against external noise

Weather grille protects against direct snow and rainfall

Aluminium casing anodised or powder-coated, PVC face plates

Thermal separation (low heat transfer via the casing)

Page 6: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

6

AEROMAT 100 Installation and operating instructions

03.2020

Operation

AEROMAT 100 Type D

1. Open the fan flap

2. Close the fan flap

1. 2.

AEROMAT 100 Type DK

1. Open the fan flap (operating lever opens automatically)

2. Close the fan flap (operating lever closes automatically)

Öffnen

Schliessen 2.

1.

Page 7: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

Installation and operating instructions AEROMAT 100

03.2020 7

Maintenance

If you notice that the ventilator does not close properly or is difficult to open because the compression strength of the fan flap is not correct, you can adjust the compression strength by means of a small screw on the front panel of the unit.

• Slightly turn the screw into the desired direction using an appropriate screwdriver. (+ = increase the compression strength; - = decrease the compression strength)

-+

Besides cleaning it, the AEROMAT 100 does not need any further maintenance. If any malfunctions arise, please contact SIEGENIA.

Cleaning

Cleaning the unit!

› Switch off all poles of the mains cable.

› If required, clean the outer parts of the AEROMAT 100's casing using a suitable cloth, which has been moistened with a mild soap sud or washing-up liquid.

› Never use cleaning agents that are aggressive or contain solvents, as these may damage the surface of the unit.

› When cleaning the unit, prevent liquid from entering the casing.

› Never clean the unit with a high-pressure cleaner or steam-jet cleaner.

Page 8: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

8

AEROMAT 100 Installation and operating instructions

03.2020

Cleaning the front panel and sealing plate

1. Close the fan flap

2. Lift and remove lid using a flathead screwdriver

2.

1.

3. Lift front panel using a flathead screwdriver

4. Pull out front panel and sealing plate from behind and pull off of the operating lever

3.4.

5. Lift-off sealing plate and front panel to clean

6. Remove foamed lining, if necessary

7. Make sure that the operating rod (a) does not slip out not of the sealing plate's profile

8. After cleaning, reassemble in the reverse order

5.

6.

a

Page 9: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

Installation and operating instructions AEROMAT 100

03.2020 9

Accessories

Please indicate the desired lengths for all accessory items (see order form AEROMAT 100).

Designation Material no. Use

Flush switch AF1, single, white 128032Type DK

Surface-mounted casing for switch AF1, white 149027

Rod operating device, white (RAL 9016)aer.gestaenge Type D

Rod operating device, silver (EV 1)

Aluminium profile 20 x 20 x 2 mm, white (RAL 9016)aer.winkel 20x20x2 Type D and DK

Aluminium profile 20 x 20 x 2 mm, silver (EV 1)Stop profile, white (RAL 9016)

aer.anschlagprofil Type D and DKStop profile, silver (EV 1)

Rod operating device (optional)

The ventilator is operated used a sliding button (a) on the rod. You can slide the button up or down manually. The sliding button’s "Open" and "Close" positions (or intermediate positions) correspond to the position of the operating lever on the unit.

The rod is mounted on the same door or window element in which the ventilator is mounted. If the ventilator is mounted in a moveable window sash, for example, it is essential to also attach the rod to the same sash profile.

Assembling the rod in three steps

Note: Depending on the assembly situation, the pin (b) and the clip (c) must be shortened.

1. Insert pin

- Open the fan flap of the AEROMAT 100, thus moving the operating lever into the upper position. Insert the provided pin (b) in the intended bore hole in the operating lever of the AEROMAT 100.

2. Adjust the rod

- The sliding button (a) of the rod must be in the upper position ("Open").

- Insert the front groove of the clip (c) into the pin (b) that is fixed above the AEROMAT 100. Push the rod against the existing profile and hold the rod with one hand.

- Now move the sliding button (a) from "Open" to "Close" and adjust the rod in such way that the fan flap closes and opens completely.

3. Secure the rod

- Directly screw the rod with wooden or self-tapping countersunk screws (provided on-site) into the existing screw holes in the adjusted position. The screw holes have the following dimensions: Ø screw hole = 3.7 mm Ø counterbore = 7.2 mm

ø 5 mm

a

b c

Page 10: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

10

AEROMAT 100 Installation and operating instructions

03.2020

Technical specifications

Specification for a AEROMAT 100 Type D/Type DK

Ventilator length (in mm increments) 508 - 3000 mmSound absorption (Rw1.9) 42 dB 39 dBSound absorption in accordance with DIN EN ISO 20140-10 (Dn,e,w) 49 dB 46 dB

Air throughput (approx.) at pressure ofmeasured with ventilator of 1,200 mm and with weather grille 911 HW/HS

2 Pa4 Pa5 Pa7 Pa8 Pa

10 Pa20 Pa

9 m³/h13 m³/h14 m³/h17 m³/h18 m³/h20 m³/h35 m³/h

13 m³/h18 m³/h21 m³/h25 m³/h27 m³/h30 m³/h43 m³/h

Electrical connection 230 V~ / max. 0.01 A (Type DK only)

Protection class I (Type DK only)

U-value (calculated in accordance with ISO 6946) 1.68 W/m²KCable outlet on the operating side of the ventilator, unit cable approx. 1.5 mSurface EV1 silver or RAL 9016 white coated (RAL special colours on request)

Dimensions

*Stop profile (accessory for glazing rebate fitting)

100

mm

140 mm

18,5 mm18

mm 5 mm

*

Feedback on documentation

We welcome your comments and suggestions on how to improve our documentation. Please email your comments to [email protected].

Page 11: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean
Page 12: AERO - downloads.siegenia.com · 4. Pull out front panel and sealing plate from behind and pull off of the operating lever 3. 4. 5. Lift-off sealing plate and front panel to clean

Contact your dealer:

Head O� ce:Industriestraße 1–357234 WilnsdorfGERMANY

Phone: +49 271 3931-0Telefax: +49 271 [email protected]

SIEGENIA worldwide:

Austria Phone: +43 6225 8301

Belarus Phone: +375 17 3143988

Benelux Phone: +31 85 4861080

China Phone: +86 316 5998198

France Phone: +33 3 89618131

Germany Phone: +49 271 39310

Great Britain Phone: +44 2476 622000

Hungary Phone: +36 76 500810

Italy Phone: +39 02 9353601

Poland Phone: +48 77 4477700

Russia Phone: +7 495 7211762

South Korea Phone: +82 31 7985590

Switzerland Phone: +41 33 3461010

Turkey Phone: +90 216 5934151

Ukraine Phone: +38 044 4054969

You can fi nd address details for our

international sites at: www.siegenia.com

H47

.FEN

S014

EN/2