Top Banner
AERIS SMARTHUB TM
3

Aeris SmartHUB Feb17

Feb 02, 2022

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Aeris SmartHUB Feb17

Aeris smArthubtm

Page 2: Aeris SmartHUB Feb17

smArthubtm reAL time OPtimisAtiONAND Asset mANAGemeNt

Centralised asset management

Optimises compressor operation with real-time

dynamic demand management

Real time monitoring,control and optimisation

Reduce operating costsand electricity usage

Better temperature controland occupant comfort

Plug and play technology can be retrofi tted to most air conditioning

and refrigeration equipment

3G/4G - wi-fi , connections

Anytime, anywhere access on any device

smArthubtm reAL time

COmPressOr OPtimisAtiON AND

Asset mANAGemeNt LeADs the WAY

Aeris SmartHUB™ combines real time monitoring, control

and dynamic compressor optimisation to deliver

measurable, instant and long lasting results

– providing signifi cant energy effi ciency, demand

management, performance, tracking and cost control for

your assets. $

smartHuB

Air CONDitiONiNG

rEFriGErAtED DisPLAY CAsEs

COOL rOOM / rEFriGErAtiON

LiGHtiNG

MEtEriNG

BOiLEr

rEFriGErAtED trANsPOrt

localise your global assets

Monitor, control and optimise your assets with Aeris SmartHUB

sOLAr PANELs (MONitOriNG)

Page 3: Aeris SmartHUB Feb17

reAL time CONtrOL AND/Or OPtimisAtiONWith Aeris smArthubtm

The proprietary Aeris SmartHUB™ combines multiple device, ‘internet of things’ functionality into one easy to install and use form factor. With 2 way communication allowing real-time system control, optimization, measurement, verification and reporting alongside our pioneering compressor optimization algorithm.

Choose from 3 configurations for your device or assets

Options include :(a) 24/7 time control(b) Temperature control(c) On/off functionality(d) I/O functionality for external devices (sensors)(e) Up to 2 stage Heat / 2 Stage Cool(f) RS 232, 485 / Modbus Interface

Aeris Environmental LtdPh : +61 2 8344 1315

Fax : +61 2 9697 0944Email : [email protected]

www.aeris.com.au

Thailand

87/30 Modern Towrn Building, 2nd Floor, Tower B

Sukhumvit Road 63 (Ekkamai) Khlongton Nua,

Wattana, Bangkok 10110

New South Wales Head Office

5/26-34 Dunning Avenue,

Rosebery, NSW 2018

Queensland

2/53 Metroplex Ave,

Murarrie, QLD 4172

AustrALiA

iNtErNAtiONAL

Singapore

Unit 01-47 Bartley Biz Centre,

15 Kaki Bukit Road 4,

Singapore 417808

Europe

11, St Francis, Triq Ta-Gawdieri,

San Gwann, SGN1740,

Malta

USA

1209 Kingsley Court

Lower Gwynedd,

PA. 19002

Middle-East

Sajaya Building-B Block 202,

PO Box 232821,

Al Qusais, Dubai, UAE

01/17

Benefits• Cost effective and cash positive solution with innovative commercial structure.• Generates actionable and measurable data, insight and savings.• Asset level solution allowing targeted reporting, control and optimisation.• Retrofit solution bringing cutting edge internet of things compatibility to existing and aged

plant.• Compatible with most air conditioning, refrigeration, building management and control

brands and technologies.• Can act as a primary or secondary (asset level) controller.• Compatible with all major third party sensor types and communication languages/protocols.• Securely sits on existing corporate communication networks or can be independent (3G/4G

- wi-fi etc).• Generates significant energy efficiency and demand management by better matching the

heat load using real-time dynamic compressor optimization algorithms.• Significantly extends asset life cycle and brings down total cost of ownership.• Reduce carbon and increase environmental footprint through efficient assets.• Can simultaneously communicate with electrical meter, water meter, boilers, variable speed

drives and other equipment.

standalone Device or Asset Controller Controller + Optimisation(HVAC or refrigeration)

inverter unit Optimisation

(a) All options included in 1, plus(b) The ability to optimise and reduce

energy consumption(c) Optimise demand management(d) Provide I/O visualisation of data &

Functionality

(a) All options included in 1, plus(b) Optimisation of demand management

1 2 3

input mA or mV Ct1 reading

Ct2 reading

Ct2 reading

AO 1 (4-20mA)

AO 1 (4-20mA)

AO 1 (4-20mA)

AO 1 (4-20mA)

AO 3 (0-10VDC)

AO 3 (0-10VDC)

AO 4 (0-10VDC)

AO 4 (0-10VDC)

Compressor 1 Control in Via N/C

Compressor 2 Control in Via N/C

Compressor 1Control Out Via CMN

Compressor 2Control Out Via CMN

N/O

N/O

N/O

N/O

N/C

N/C

CMN

CMN

input mA or mV

input mA or mV

input mA or mV

input mA or mV

input mA or mV

input mA or mV

input mA or mV

Di From Compressor Contactor 1

Di From Compressor Contactor 1

Di From Compressor Contactor 2

Di From Compressor Contactor 2

Di/Ai 3

Di/Ai 3

Di/Ai 4

Di/Ai 4

rs232 input

rs232 input

rs485 input

rs485 input

Modbus

Modbus

110/220VAC + 12VDC +

110/220VAC - 12VDC -

GsM sD CArD