ADVANCE GRP Series 125A Switched Interlocked socket outlets
ADVANCE GRP Series 125A
Switched Interlocked socket outlets
2
With switch-disconnector
With contactor
With switch-disconnector and fuse
With fuse and switch
With molded case circuit breaker with
thermal magnetic trip unit
With molded case circuit breaker with
thermal magnetic and residual current
release trip units
> VERSIONS WITH MECHANICAL INTERLOCK
> VERSIONS WITH ELECTRICAL INTERLOCK
EN 60309-1
Plugs, socket outlets and couples for industrial purposes.
Part 1: general requirements.
EN 60309-2
Plugs, socket outlets and couples for industrial purposes.
Part 2: dimensional interchangeability requirements for pin
and contact-tube accessories of harmonised configurations.
EN 60309-4
Plugs, socket-outlets and couplers for industrial purposes.
Part 4: Switched socket-outlets
and connectors with or without interlock.
IEC 61241-0 / EN 61241-0
Electrical apparatus for use
in the presence of combustible dust.
Part 0: General requirements.
IEC 61241-1 / EN 61241-1
Electrical apparatus for use
in the presence of combustible dust.
Part 1: Protection by enclosures 'tD'.
> SWITCHED INTERLOCKED SOCKET OUTLETS > REFERENCE STANDARDS
ADVANCE GRP Series 125A
Scame offers products suitable for installation into
environments under potential risk of explosion identified as
Zone 22 and that enter into the field of application for the
ATEX Directive (European Directive 94/9/CE).
> PRODUCTS FOR USE IN A POTENTIALYEXPLOSIVE ENVIRONMENT
3
Via Costa Erta 15 Parre BG ITALY
D O N O T O P E N W H E N E N E R G I Z E D
I N P R E S E N C E O F E X P L O S I V E A T M O S P H E R E
I I 3 D
5 0 3 . 1 2 5 8 7 - FC o d .
S C A M E A T E X 0 2
I P 6 6 T 9 0 ° C
E x t D A 2 2
3P+N+ - 125A - 6h / 346-415V~
Rated current: 125A
Rated voltage: 100÷690V~
Frequency: 50÷60Hz
Insulating voltage: 500/690V~
Protection degree: IP66
Operating temperature
according to the
reference standard: -25°C+40°C
Max. operating
temperature: 60°C
Self-extinguishing GW test: 850°C/960°C
Self-extinguishing UL94: V0
Material: Thermoset
IK degree at 20°C: IK10
Cable inlets: Top side max 3xM63
Bottom side max 2xM63
Switch-disconnectors: ABB OT 160
Fuse: NH00
Thermal magnetic protection: Molded case circuit breaker
ABB Tmax T1B (16kA) with
thermal magnetic trip unit
TMD (adjustable thermal
threshold 0,7…1 x In fixed
magnetic threshold 10 x In)
Thermal-magnetic and Molded case circuit breaker
residual current protection: ABB Tmax T1B (16kA) with
thermal magnetic trip unit
TMD (adjustable thermal
threshold 0,7…1 x In fixed
magnetic threshold 10 x In) +
residual current release trip
units RC221/1 (adjustable
residual current trip 0,03 - 0,1
- 3A and time limit for non-trip
instantaneous)
Version with contactor: Contactor CL09 GE POWER
CONTROL
Colour: Grey RAL7037
> TECHNICAL CHARACTERISTICS > EX CLASSIFICATION
Rated current
(A)
125A 25 70
Socket outlets
Min Max
16 50
Plugs
Min Max
ResistantLimited
ResistanceResistant
NotResistant
ResistantLimited
ResistanceLimited
ResistanceLimited
ResistanceLimited
ResistanceResistant Resistant
AD
VA
NCE G
RP S
erie
s 1
25A
> WIRING OPERATIONSWiring capacity of the terminals (mm2)
> BEHAVIOUR WITH CHEMICAL AND ATMOSPHERIC AGENTS
Atex Code: II 3D
Ex Protection type: Ex tD A22 IP66 T90°C
Operating Temperature
Range: -25°C +60°C
Maximum permissible
surface temperature: T90°C
Switched socket outlets with
interlock degree of Protection: IP66
Plugs - degree of Protection: IP66/IP67
Impact Resistance: 7J
Switched socket outlets with
interlock material: Thermoset
Plugs material: Thermoplastic
Interlocked switch sockets
outlets CE certificate: SCAME ATEX 02
Plugs CE certificate: SCAME ATEX 03
Saline solution
Acids
Concentrated Diluted Concentrated Diluted Hexane Benzol Acetone Alcohol
Bases SolventsMineraloil
UV rays
For specific substances please contact our technical service
4
> APPLICATION EXAMPLES
ADVANCE GRP Series 125A
5
> TECHNICAL DATA SWITCH DISCONNECTORS
Rated insulation voltage Ui
Rated impulse withstand voltage Uimp
Thermal current Ith
Thermal current Ithe
AC21A Resistite loads, inludingmoderate overloads
AC22AMixed resistite and inductive loads,including moderate overloads
AC23ASwitching off motor loads or otherhighly inductive loads(3 phase/3 pole)
DC21AResistite loads, includingModerate overloads
DC22AMixed resistite and inductive loads,including moderate overloads
Conditional short-circuit current
General applications - Single-phase and Three-phase
AC motor, all-pole interruption - Single-phase
AC motor, B, C, D, all-pole interruption - Three-phase
Associate fuse size for conditionalshort-circuit current - Type gG
Rated short-circuit making capacity Icm
Wire
AC3 Squirrel-cage motor: starting,switching off motor during running (3 phase/ 3 pole)
Nominal current rating Ie
Short-circuit
protection
Permissible wire
range
Rated current UL
Rated short-time withstand current Icw (s)
125A
750
750
12
200
-
200
-
160
200
-
160
135
125
80
-
-
160(*)
4000
Vac
Vdc
400V
500V
690V
A
A
A
kV
A
A
400V
500V
690V
A
A
A
400V
500V
690V
A
A
A
300V A
250V
600V
A
A
160(*)
-
A
400V
690V
A
A
24
30
1200
500V
kA
kA
kA
600V A 125
7,5
20
40
75
100
120V
240V
240V
480V
600V
Hp
Hp
Hp
Hp
Hp
10-70
8-1/10
mm2
AWG
(*) 2+2 poles in series
AD
VA
NCE G
RP S
erie
s 1
25A
6
Ample space for
easy wiring
Outdoor wall
fastening
Under-plate cable
runway
Switch-
disconnector with
mechanical lock
that can be
accessorized with
auxiliary contacts
Punched marks for
easy closure of the
cover
BOTTOM VIEW TOP VIEW
Threaded metal
inserts
Easily extractable
bottom plate
Possibility to
assemble
microswitch
Module in high-
temperature glass-
fibre filled
engineering
polymer
Possible entry from
bottom side (input-output also)
Self-centering punch
marks to facilitate drilling
ADVANCE GRP Series 125A
7
Double mechanical
lock and metal
levers
Single-piece
waterproof gasket
Rating on metal
plate
Lockable
Switch
in position 0
and 1
High-strength
material with
superior UV and
chemical
resistance
Captive stainless
steel closing
screws
Cover entirely
separate from the
base for easy
installation
An electronic device controls the status of the interlocked socket, monitoring the electrical
functionality:
- operation of the signalling and control card is guaranteed even when the load is not
connected;
- indicates that the fuses are not open and all the phases are present (indicator light on);
- indicates that the socket outlet is powered correctly (indicator light on);
- signals the interruption of one or more fuses (indicator light flashing);
- signals the absence of a phase (indicator light flashing)*;
- indicates that the socket outlet is not powered (indicator light off).
* for single-phase products in the event of phase/ neutral loss LED signaling appears off.
Residual current
release trip units
test push button
AD
VA
NCE G
RP S
erie
s 1
25A
8
> MECHANICALLY INTERLOCKED SOCKET OUTLETS - IP66
2P+E 125A 50/60 200-205V 6 1 503.12583-M
3P+E 125A 50/60 380-415V 6 1 503.12586-M
3P+N+E 125A 50/60 346-415V 6 1 503.12587-M
2P+E 125A 50/60 200-205V 6 1 503.12583-F
3P+E 125A 50/60 380-415V 6 1 503.12586-F
3P+N+E 125A 50/60 346-415V 6 1 503.12587-F
2P+E 125A 50/60 200-205V 6 1 503.12583-RM
3P+E 125A 50/60 380-415V 6 1 503.12586-RM
3P+N+E 125A 50/60 346-415V 6 1 503.12587-RM
2P+E 125A 50/60 200-205V 6 1 503.12583-FS
3P+E 125A 50/60 380-415V 6 1 503.12586-FS
3P+N+E 125A 50/60 346-415V 6 1 503.12587-FS
2P+E 125A 50/60 200-250V 6 1 503.12583
3P+E 125A 50/60 380-415V 6 1 503.12586
3P+N+E 125A 50/60 346-415V 6 1 503.12587
Plug Hz Volt Colour
Plug Hz Volt Colour
Hz Volt Colour
Hz Volt Colour
h
h
h
Plug
Hz Volt ColourPlug
Plug
h
h
Description
Description
Description
Description
Description
Switch-
disconnector
Switch-
disconnector
and fuse (*)
Fuse (*)
and switch
Molded case
circuit breaker
with thermal
magnetic trip unit
Molded casecircuit breaker withthermal magneticand residual currentrelease trip units
(*) Fuses not included Pack Quantity.
ADVANCE GRP Series 125A
9
> COMPLEMENTARY PRODUCTS - OPTIMA-EX SERIES - PLUGS IP66/IP67
> ACCESSORIES
> ELECTRICALLY INTERLOCKED SOCKET OUTLETS - IP66
1NO+1NC 4x4 mm2 579.0125
2P+E 125A 50/60 200-205V 6 1 503.12583-T
3P+E 125A 50/60 380-415V 6 1 503.12586-T
3P+N+E 125A 50/60 346-415V 6 1 503.12587-T
2P+E 125A 50/60 200-250V 6 1 218.EX12533
3P+E 125A 50/60 380-415V 6 1 218.EX12536
3P+N+E 125A 50/60 346-415V 6 1 218.EX12537
Plug Hz Volt Colour
Terminals Contacts
h
Hz Volt Colour hPlug
Description
Description
Description
Plugs
Microswitch kit 400V 10A
(microswitch + terminal block)
Contactor (*)
(*) Microswitch already provided.
Contactor operated by microswitch.
For products with mechanical interlock.
AD
VA
NCE G
RP S
erie
s 1
25A
10
> DIMENSIONS
(Dimensions in mm)
ADVANCE GRP Series 125A
11
(Dimensions in mm)
Switch-disconnector Switch-disconnector and fuse Fuse and switch
Molded case circuit breaker with
thermal magnetic trip unit
Molded case circuit breaker with
thermal magnetic and residual
current release trip units
Contactor
AD
VA
NCE G
RP S
erie
s 1
25A
ScameOnLine
SCAME PARRE S.p.A.
VIA COSTA ERTA, 15
24020 PARRE (BG) ITALY
TEL. +39 035 705000
FAX +39 035 703122
www.scame.com
ZP00738-G
B-2