Top Banner
Adult & Paediatric Speciality Laryngoscope Blades Sterile Single-Use
4

Adult & Paediatric Speciality Laryngoscope Blades Sterile ... · Eliminates back-glare. Reduction in the shoulder and block height reduces the risk of dental trauma and provides ...

May 30, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Adult & Paediatric Speciality Laryngoscope Blades Sterile ... · Eliminates back-glare. Reduction in the shoulder and block height reduces the risk of dental trauma and provides ...

Adult & Paediatric Speciality Laryngoscope Blades

Sterile Single-Use

Page 2: Adult & Paediatric Speciality Laryngoscope Blades Sterile ... · Eliminates back-glare. Reduction in the shoulder and block height reduces the risk of dental trauma and provides ...

Reduced Shoulder and Block HeightImproved access and greater field of view.

Symmetrical Focussed Light SpreadDirect illumination of the glottic area.

Lateralised Light BundleUnrestricted line of sight.

Shrouded Light Bundle and Non-reflective Coating Eliminates back-glare.

Reduction in the shoulder and block height reduces the risk of dental trauma and provides additional space to manoeuver the blade to obtain the best view.

Reduced Shoulder and Block HeightLess risk of dental damage.

Non-touch Hinge MechanismProtection from blade tip contaminatingthe handle.

All Metal One-piece BladeNo breakable plastic block.

Rounded Tip and EdgesReduces risk of soft tissue damage.

Sterile PackedFree from contamination.

BriteBlade Pro lightspread

Traditional lightspread

Excellent Visualisation

Reduced Profile

Speciality Adult & Paediatric Sterile All Metal Single-Use Fibre Optic Laryngoscope Blades

Typical overall height reduction is up to 25% in straight blades.

BriteBlade Pro blade Traditional blade

25%Reduction

Page 3: Adult & Paediatric Speciality Laryngoscope Blades Sterile ... · Eliminates back-glare. Reduction in the shoulder and block height reduces the risk of dental trauma and provides ...

MILLER SEWARD ROBERTSHAW WIS-HIPPLE

040-00-04000 Size 000 10

040-720N Size 00 10

040-720 040-00-1101 Size 0 10

040-721 040-00-0810 040-00-1110 040-00-1210 Size 1 10

040-00-1215 Size 1.5 10

040-00-0820 Size 2 10

POLIO KESSEL PHILLIPS

040-741 Size 1 10

040-742 Size 2 10

040-673 040-683 Size 3 10

040-674 040-684 Size 4 10

Polio

Miller

Kessel

Seward

Phillips

Robertshaw

Wis-Hipple

Speciality Paediatric Blades

Speciality Adult Blades

Page 4: Adult & Paediatric Speciality Laryngoscope Blades Sterile ... · Eliminates back-glare. Reduction in the shoulder and block height reduces the risk of dental trauma and provides ...

040-813BritePro Max LED Standard Handle

1

040-814BritePro Max LED Mini Handle

1

040-815BritePro Max LED Stubby Handle

1

040-310 BritePro Solo Handle 20

040-309 BritePro Solo Mini Handle 20

040-03-0000 BritePro Solo Stubby Handle 20

FC3446 | 012018

Flexicare Medical Limited. Cynon Valley Business Park, Mountain Ash, CF45 4ER, UK.

+44 (0)1443 474222+44 (0)1443 474647 [email protected] www.flexicare.com

BritePro Max LED BritePro Max Reusable Handles use the latest LED technology to deliver a bright white light for a clearer view of the larynx and a true visualisation of tissue structures.

TM

The Complete Solution Single-Use BritePro Solo helps eliminate cross-contamination, and eradicate reprocessing costs and performance issues associated with reprocessing reusable laryngoscopes.

BriteBlade and BritePro are registered trade marks of Flexicare Medical Ltd.