Page 1: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP
Page 2: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

PRODUCT REGISTRATIONSAd-Tech Medical Instrument Corporation is proud to be an FDA and ISO registered company. Unless

REFERENCESAd-Tech has over 100 medical journal articles that represent the use of our products. Please contact Ad-Tech to receive a reprint. Please note that the authors do not present a commercial description.

otherwise stated, all products within this catalog meet the regulatory requirements of the FDA, the Therapeutic Products Directorate of Canada and the Medical Device Directive of the European Union. Our subdural, depth and sphenoidal electrodes have governmental clearance to be placed in the body for up to 30 days. To determine the regulatory status of Ad-Tech products in any country, or to receive a copy of the applicable indication for use statements, please contact Ad-Tech or your local Ad-Tech distributor.

MKTG-3006, Rev. O© 2011

WELCOME!Welcome to Ad-Tech’s catalog of products for the surgical treatment of epilepsy and for neurosurgery. We wish to thank you for your support and for choosing Ad-Tech.

MR CONDITIONALAd-Tech tested an assortment of electrodes in a Siemens Trio (actively sheilded whole body 3T magnet). In accordance with ASTM F2052-02 Standard Text Method for measurement of Magnetically Induced Displacement Force on Medical Devices in the Magnetic Resonance Environment (2003). For a more complete MR report, contact your Ad-Tech representative.

Page 3: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

TABLE OF CONTENTS

0 0 8 6

Cables, Blocks,Placement Instruments & Guides

DEPTH ELECTRODE PLACEMENT KITS & ACCESSORIESDepth Electrode Placement Kits ...................................................................................................................... 24Depth Electrode Cannulas ............................................................................................................................... 24Depth Electrode Anchor Bolts ......................................................................................................................... 25Disposable Drill Kits ......................................................................................................................................... 25Passing Needles .............................................................................................................................................. 26

SPHENOIDAL ELECTRODESSphenoidal Electrodes ..................................................................................................................................... 26

SUBPIAL TRANSECTORSSubpial Transector ........................................................................................................................................... 27

ELECTRODE CONNECTION SYSTEMSElectrode Cable Splitter Box ............................................................................................................................ 27Lightweight Electrode Connection Systems .................................................................................................... 28

DISPOSABLE BRAIN BIOPSY NEEDLES & ELECTRODE ACCESSORIESDisposable Brain Biopsy Needles ................................................................................................................... 30Brain Biopsy Needle Guides ............................................................................................................................ 30Disposable Reducing Guide Kits ..................................................................................................................... 30

CRANIAL NERVE MONITORING ELECTRODESIntraoperative Cranial Nerve Electrodes .......................................................................................................... 31

IVES SCALP ELECTRODESCT Compatible Scalp Electrodes ..................................................................................................................... 32Subdermal Wire Electrodes ............................................................................................................................. 33

GENERAL INFORMATIONProduct Registrations & References.................................................................................................................. 2

PageSUBDURAL ELECTRODESContoured Subdural Grid Electrodes ................................................................................................................. 4Single-Tail Subdural Grid Electrodes ................................................................................................................. 5Perpendicular-Tail Subdural Grid Electrodes ..................................................................................................... 6Multi-Strip & Split-Grid Subdural Electrodes...................................................................................................... 7Subdural Grid Electrodes .................................................................................................................................. 8Temporal Lobe Subdural Grid Electrodes ........................................................................................................ 10“L” & “T” Shaped Subdural Strip & Grid Electrodes .......................................................................................... 11Subdural Strip Electrodes ................................................................................................................................ 12Narrow-Body Subdural Strip Electrodes .......................................................................................................... 133D Style Subdural Strip Electrodes ................................................................................................................. 13Macro-Micro Strip Electrodes .......................................................................................................................... 14Dual-Sided Interhemispheric Subdural Strip & Grid Electrodes ...................................................................... 15

DEPTH & FORAMEN OVALE ELECTRODESMacro-Micro Depth Electrodes ........................................................................................................................ 19Behnke Fried Depth Electrodes ....................................................................................................................... 20Foramen Ovale Electrodes .............................................................................................................................. 21Spencer® Probe Depth Electrodes .................................................................................................................. 22

EPIDURAL SPINAL & INTRAOPERATIVE MAPPING ELECTRODESIntraoperative Monitoring Subdural Strip Electrodes ....................................................................................... 16Intraoperative Monitoring Electrodes with Attached Cables ............................................................................ 17Intraoperative Mapping Electrode System ....................................................................................................... 18Epidural Spinal Electrodes .............................................................................................................................. 18

All specifications and claims are subject to change without notice.All products may be covered by one or more of the following USA Patents:5,375,594 - 6,004,262 - 6,415,168 - 6,629,900 - 6,656,1526,671,534 - 7,134,919 - 7,241,283 - 7,255,686 - 7,277,7427,322,954 - 7,425,142 - 7,465,292 - 7,536,215 - 7,607,224

7,608,064Foreign Patents and Patents Pending

* Subpial Transectors, Cranial Nerve Electrodes, and Ives Scalp Electrodes are NOT CE Marked.

Page 4: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

4

CABRIO® TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Block Qty

FG64C-SP10X-0C6 8 x 8, 4 tails LTM contoured grid L-SRL-64BDIN L-DCL-64BDIN DC-16X (4)FG64C-SP10X-0CB 8 x 8, single-tail LTM contoured grid

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

® EPILEPSY/LTM CONTOURED SUBDURAL GRID ELECTRODES� Contoured shape may provide more fl exibility to conform to the brain. Contact Ad-Tech to inquire if your favorite

electrodes can also be contoured� Numbered, platinum contacts, 4.0 mm diameter with a 2.3 mm exposure� May be used with the single-tail passing needles: (see page 26)� 10 mm contact spacing standard, additional spacing available � Sterile; single-use only

19

57 58 60 61 62 63

80 mm

80 mm

6459

2 3 4 5 6 7

10 11 12 14 15

17 18 19 20 21 22 23

25 26 27 28 29 30 31

33 34 35 36 37 38 39

41 42 43 44 45 46 47 48

49 52 53 54 55 565150

816

2432

40

12.1 mm

Electrodes are shown with the exposed

contact surfaces facing DOWN .80 mm

FG64C-SP10X-0CB64-contact, single-tail LTM contoured grid

80 mm

2 3 4 5 6 7

10 11 12 13 14 15

17 18 19 20 21 22 23

25 26 27 28 29 30 31

33 34 35 36 37 38 39

41 42 43 44 45 46 47 48

49 52 53 54 55 565150

816

2432

40

1

64

957 58 6059 61 62 63 64

1

FG64C-SP10X-0C664-contact, 4-tails LTM contoured grid

1.5 mm

375 mm

64

13

0 0 8 6

Cables & Blocks

190.5mm

RoTecTM

L-RTL-64BDIN Cable

66 mm long

2 mm inner diameter

3 mm outer diameter

Page 5: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 5

RoTecTM

Cable

60 mm long

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40

41 42 43 44 45 46 47 48

49 52 53 54 55 56

57 58 60 61 62 63

2 3 4 5 6 8

9 10 11 12 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 31 32

2 3 4 5

6 7 8 9

13 15

16 17 20

38 mm

90 mm

80 mm

38 mm

60 mm

0.7 mm

Endview

10 mm

90 mm

IG20C-SP10X-0TB20-contact, single-tail LTM grid

IG64C-SP10X-0TB64-contact, single-tail LTM grid

7

12

18 19

51

101.5 mm

6459

13 14

14

® EPILEPSY/LTM SINGLE-TAIL SUBDURAL GRID ELECTRODES� Tails terminate in standard confi gurations (uses TECH-ATTACH, CABRIO OR RoTec cables)� Numbered, platinum contacts 4.0 mm diameter with 2.3 mm exposure� May be used with the single-tail passing needles: (see page 26)� Single-tail construction reduces the number of tunnels� 60 cm tail length� Sterile; single-use only

111.5 mm

2.1 mm

2.1 mm

IG32C-SP10X-0TB32-contact, single-tail LTM grid

Platinum marker(typical)

CABRIO® TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Block Qty

IG20C-SP10X-0TB 4 x 5 LTM grid L-SRL-20DIN L-RTL-20DIN L-DCL-20DIN DC-10X (2)IG32C-SP10X-0TB 4 x 8 LTM grid L-SRL-32BDIN L-RTL-32BDIN L-DCL-32BDIN DC-16X (2)IG64C-SP10X-0TB 8 x 8 LTM grid L-SRL-64BDIN L-RTL-64BDIN L-DCL-64BDIN DC-16X (4)

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

30

1

1

50

10mm

1

64

1

32

1

20

600 mm

60 mm long

66 mm long

2 mm inner diameter

3 mm outer diameter

2 mm inner diameter3 mm outer diameter

2 mm inner diameter3 mm outer diameter

Page 6: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

6

80 mm

FG64C-SP10X-0D164-contact, 4-tails @ 90o from ctr LTM grid

Platinum marker(typical)

FG64C-SP10X-00664-contact, 4-tails @ 90o from center,

tails positioned close together LTM grid

375 mm

Side view: FG64C-SP10X-0D1 & FG64C-SP10X-006

1

64

1

64

80 mm

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40

41 42 43 44 45 46 47 48

49 52 53 54 55 56

57 58 60 61 62 63

51

6459

50

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40

41 42 43 44 45 46 47 48

49 52 53 54 55 56

57 58 60 61 62 63

51

6459

50

® EPILEPSY/LTM PERPENDICULAR-TAIL SUBDURAL GRID ELECTRODES� Perpendicular tail design may allow for a smaller craniotomy� Numbered, platinum contacts, 4.0 mm contacts with 2.3 mm exposure� Sterile; single-use only� Also available, contoured and slit

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

1.5 mm

10mm

10 mm

RoTecTM

Cable CABRIO® TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Block Qty

FG64C-SP10X-0D1 8 x 8, 4-tails, 90o-ctr LTM grid L-SRL-64BDIN L-RTL-64BDIN L-DCL-64BDIN DC-16X (4)FG64C-SP10X-006 8 x 8, 4-tails, 90o-ctr LTM grid2

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.2 The tails on this grid are positioned close to its center.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

0 0 8 6

Cables & Blocks

Page 7: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 7

® EPILEPSY/LTM MULTI-STRIP & SPLIT-GRID SUBDURAL ELECTRODES� Markers as shown� Sterile; single use only� Platinum contacts, 4.0 mm diameter with a 2.3 mm exposure� Multi-strip and split-grid construction reduces the number of tunnels� May be used with the single-tail passing needles (see page 26)� 37.5 cm tail length

HG32A-SP05X-00032-contact, 2-tails split-grid LTM grid

1

32

GG_ _ _-SP10X-100 SeriesMulti-strip LTM subdural electrode series

(GG48A-SP10X-100 shown)130 mm4

1

2

3

Platinum numbermarker (typical)

1

LastLast contact

(typical)

Contact #1(typical)

Electrodes are shown with the exposed contact surfacesfacing DOWN.

1.5 mm

Platinum marker(typical)

1 2 3 4 5 6 7 8

9

10 11 12 13 14 15 16

45 mm

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

20 mm

57 mm

10 mm

5 mm

64 mm

8 m

m

RoTecTM

Cable No. of Contact CABRIO® TECH-ATTACH® ComponentsCatalog Number Description1 Contacts Spacing Cable Cable Block QtyGG32A-SP10X-100 4 x 1 x 8, 2-tails 32 10 L-SRL-32BDIN L-RTL-32BDIN L-DCL-32BDIN DC-16X (2)GG48A-SP10X-100 4 x 1 x 12, 4-tails 48 10 L-SRL-48DDIN L-RTL-48DDIN L-DCL-48DDIN DC-12X (4)HG32A-SP05X-000 2 x 2 x 8, 2-tails 32 5 L-SRL-32BDIN L-RTL-32BDIN L-DCL-32BDIN DC-16X (2)

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.� Please contact your Ad-Tech representative for alternative designs or other special requirements

Page 8: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

8

® EPILEPSY/LONG TERM MONITORING (LTM) SUBDURAL GRID ELECTRODES� Epilepsy/LTM subdural electrodes are for monitoring/mapping the cortical surface for the surgical treatment of epilepsy� Numbered, platinum or stainless steel contacts, 4.0 mm diameter with 2.3 mm exposure� Sterile; single-use only� Please contact your Ad-Tech representative for alternative designs or other special requirements (ie: 5mm spacing)

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

FG08A-SP10X-0008-contact, 1-tail LTM grid

375 mm

40 mm

1.5 mm

1 81 2 3 4

5 6 7 8

18 mm

FG16A-SP10X-000 & FG16A-SS10X-00016-contact, 1-tail LTM grid

80 mm

18 mm 1 161 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

10 mm

0.7 mm

Endview

FG20C-SP10X-000 & FG20C-SS10X-00020-contact, 2-tails LTM grid

50 mm

38 mm

1

20

1 2 3 4 5

6 7 8 9 10

11 12 13 14 15

16 17 18 19 20

Platinum marker(typical)

FG32C-SP10X-000 & FG32C-SS10X-00032-contact, 2-tails LTM grid

80 mm

38 mm

10mm

1

32

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

� All electrodes can be manufactured contoured and slit upon request

No. of Contact CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Contacts Material Cable Cable Cable Block Qty

FG08A-SP10X-000 2 x 4, 1-tail LTM grid 8 platinum L-SRL-8DIN FG16A-SP10X-000 2 x 8, 1-tail LTM grid 16 platinum L-SRL-16BDIN FG20C-SP10X-000 4 x 5, 2-tails LTM grid 20 platinum L-SRL-20DIN FG32C-SP10X-000 4 x 8, 2-tails LTM grid 32 platinum L-SRL-32BDIN

L-RTL-8DINL-RTL-16BDINL-RTL-20DINL-RTL-32BDINL-RTL-16BDINL-RTL-20DINL-RTL-32BDIN

FG16A-SS10X-000 2 x 8, 1-tail LTM grid 16 stainless L-SRL-16BDIN FG20C-SS10X-000 4 x 5, 2-tails LTM grid 20 stainless L-SRL-20DIN FG32C-SS10X-000 4 x 8, 2-tails LTM grid 32 stainless L-SRL-32BDIN

L-DCL-8DIN DC-8X (1)L-DCL-16BDIN DC-16X (1)L-DCL-20DIN DC-10X (2)L-DCL-32BDIN DC-16X (2)L-DCL-16BDIN DC-16X (1)L-DCL-20DIN DC-10X (2)L-DCL-32BDIN DC-16X (2)

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

0 0 8 6

Cables & Blocks

Page 9: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 9

FG48G-SP10X-00048-contact, 3-tails LTM grid

80 mm

60 mm

1

48

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40

41 42 43 44 45 46 47 48

® EPILEPSY/LONG TERM MONITORING (LTM) SUBDURAL GRID ELECTRODES

80 mm375 mm

80 mm

FG64D-SP10X-000 & FG64D-SS10X-00064-contact, 8-tails LTM grid

FG64C-SP10X-000 & FG64C-SS10X-00064-contact, 4-tails LTM grid

1

64

1

64

1 2 3 4 5 6 7 8

10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 38 39 40

41 42 43 44 45 46 47 48

49 52 53 54 55 56

57 58 60 61 62 63

51

6459

50

1 2 3 4 5 6 7 8

9 10 11 12 13 14 15 16

17 18 19 20 21 22 23 24

25 26 27 28 29 30 31 32

33 34 35 36 37 38 39 40

41 42 43 44 45 46 47 48

49 52 53 54 55 56

57 58 60 61 62 63

51

6459

50

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

1.5 mm

37

9

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

No. of Contact CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Contacts Material Cable Cable Cable Block Qty

FG48G-SP10X-000 6 x 8, 3-tails LTM grid 48 platinum L-SRL-48BDIN FG64C-SP10X-000 8 x 8, 4-tails LTM grid 64 platinum L-SRL-64BDIN FG64D-SP10X-000 8 x 8, 8-tails LTM grid 64 platinum L-SRL-64DIN FG64C-SS10X-000 8 x 8, 4-tails LTM grid 64 stainless L-SRL-64BDIN

L-RTL-48BDINL-RTL-64BDINL-RTL-64DINL-RTL-64BDINL-RTL-64DINFG64D-SS10X-000 8 x 8, 8-tails LTM grid 64 stainless L-SRL-64DIN

L-DCL-48BDIN DC-16X (3)L-DCL-64BDIN DC-16X (4)L-DCL-64DIN DC-8X (8)L-DCL-64BDIN DC-16X (4)L-DCL-64DIN DC-16X (8)

Page 10: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

10

CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Cable Block Qty

FG35D-SP10X-Z00 Right temporal lobe LTM grid L-SRL-35DIN L-RTL-35DIN L-DCL-35DIN DC-11X (1)FG35E-SP10X-Z00 Left temporal lobe LTM grid DC-12X (2)

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

® EPILEPSY/LTM TEMPORAL LOBE SUBDURAL GRID ELECTRODES� Right and left electrodes are designed for the temporal and sub-temporal cortex� Numbered, platinum contacts, 4.0 mm diameter wih 2.3 mm exposure� Sterile; single-use only

60 mm

FG35E-SP10X-Z0035-contact, left temporal lobe LTM grid

1

3 5

19 20

13 14

7 8

1 2

34 35

31 32 33

28 29 30

25 26 27

21 22 23 24

15 16 17 18

10 11 12

4 5 6

93

30 mm

10mm

FG35D-SP10X-Z0035-contact, right temporal lobe LTM grid

375 mm

1

3 5

19 20

13 148

1 2

34 35

31 32 33

28 29 30

25 26 27

21 22 23 24

15 16 18

10 11 12

4 5 63

80 mm

40 mm

10 mm

7 9

17

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

Platinum marker(typical)

1.5 mm

0 0 8 6

Cables & Blocks

Page 11: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 11

CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Cable Block Qty

MS08L-SP10X-A00 Reversed “L” shaped LTM strip L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)MS08I-SP10X-B00 “L” shaped LTM strip MS08L-SP10X-E00 Curved, reversed “L” LTM strip MS08I-SP10X-F00 Curved “L” shaped LTM strip MS08R-SP10X-C00 “T” shaped LTM strip FG08C-SP10X-000 “T” shaped LTM grid

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

® EPILEPSY/LTM “L” & “T” SHAPED SUBDURAL STRIP & GRID ELECTRODES� Numbered, platinum contacts with platinum markers as shown, 4.0 mm diameter with a 2.3 mm exposure� “L” and “T” shapes offer you different tail-exit options� 37.5 cm tail length� Sterile; single-use only

0.7 mm

Endview

MS08L-SP10X-A008-contact, reversed

“L” shaped LTM strip

MS08I-SP10X-B008-contact, “L” shaped LTM strip

1

8

1

8

MS08R-SP10X-C008-contact, “T”

shaped LTM strip

81mm

81 38mm

20 mm

35

71

46

82

FG08C-SP10X-0008-contact, “T”

shaped LTM grid

81

MS08I-SP10X-F008-contact, curved “L” shaped LTM strip

1

8MS08L-SP10X-E008-contact, curved reversed “L”

shaped LTM strip

Platinum marker(typical)

1

8

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

8 7 6 5 4 3 2 11 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8 8 7 6 5 4 3 2 1

32

14

76

58

1.5 mm

10 mm

78 mm

8 mm

Page 12: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

12

Contact Contact CABRIO® RoTec® TECH-ATTACH® ComponentsCatalog Number Description1 Material Spacing Cable Cable Cable Block Qty

TS02R-SP10X-000 1 x 2 LTM strip platinum 10 L-SRL-2DIN L-RTL-2DIN L-DCL-2DIN DC-2X (1)TS04R-SP10X-000 1 x 4 LTM strip platinum 10 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)TS04R-SP15X-000 1 x 4 LTM strip platinum 15 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)TS06R-SP10X-000 1 x 6 LTM strip platinum 10 L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)TS08R-SP10X-000 1 x 8 LTM strip platinum 10 L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)TS10R-SP10X-000 1 x 10 LTM strip platinum 10 L-SRL-10DIN L-RTL-10DIN L-DCL-10DIN DC-10X (1)TS12R-SP10X-000 1 x 12 LTM strip platinum 10 L-SRL-12BDIN L-RTL-12BDIN L-DCL-12BDIN DC-12X (1)TS04R-SS10X-000 1 x 4 LTM strip stainless 10 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)TS04R-SS15X-000 1 x 4 LTM strip stainless 15 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)TS06R-SS10X-000 1 x 6 LTM strip stainless 10 L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)TS08R-SS10X-000 1 x 8 LTM strip stainless 10 L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)

50 mm

65 mm

70 mm

110 mm

130 mm

TS04R-SP10X-000 & TS04R-SS10X-0004-contact LTM strip

TS12R-SP10X-00012-contact LTM strip

TS04R-SP15X-000 & TS04R-SS15X-0004-contact LTM strip (15 mm spacing)

TS08R-SP10X-000 & TS08R-SS10X-0008-contact LTM strip

TS10R-SP10X-00010-contact LTM strip

15 mm

90 mm

35 mmTS02R-SP10X-000

10 mm

1.5 mm

Contact #1(typical)

375 mm

1 12

1 10

1 8

1 6

1 4

1 4

1 2

TS06R-SP10X-000 & TS06R-SS10X-0006-contact LTM strip

8 mm

0.7 mmend view

® EPILEPSY/LONG TERM MONITORING SUBDURAL STRIP ELECTRODES� 8 mm width � Thin and fl exible � Sterile; single-use only� Platinum or stainless steel contacts, 4.0 mm diameter with a 2.3 mm exposure� Non-numbered with reinforcement, designed for long-term monitoring applications

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

2-contact LTM strip(commonly used as a reference)

0 0 8 6

Cables & Blocks

Page 13: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 13

® EPILEPSY/LTM NARROW-BODY SUBDURAL STRIP ELECTRODES� 4.0 mm contact diameter with reduced contact exposure (1.8 mm), may aid during electrode removal� Non-numbered with reinforcement, designed for long-term monitoring applications� Platinum contacts � Thin and fl exible � Sterile; single-use only � 6 mm width

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

0.7 mmend view

® EPILEPSY/LTM 3D STYLE SUBDURAL STRIP ELECTRODES� Large, indented 6.0 mm diameter contacts with 4.0 mm diameter exposed recording area� Numbered, platinum contacts

cross-section view of 3D style contact

End

0.7 mm

view

CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Cable Block Qty

TS04R-AP10X-0W6 1 x 4 narrow-body strip L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)TS06R-AP10X-0W6 1 x 6 narrow-body strip L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)TS08R-AP10X-0W6 1 x 8 narrow-body strip L-SRL-8DIN L-RTL-6DIN L-DCL-8DIN DC-8X (1)

Electrodes areshown with the

exposed contactsurfaces facing

DOWN .

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Cable Block Qty

MS04R-IP10X-000 1 x 4 large, 3D style strip L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)MS06R-IP10X-000 1 x 6 large, 3D style strip L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)MS08R-IP10X-000 1 x 8 large, 3D style strip L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)MS10R-IP10X-000 1 x 10 large, 3D style strip L-SRL-10DIN L-RTL-10DIN L-DCL-10DIN DC-10X (1)

1 2 3 4 5 6 7 8

95 mmMS08R-IP10X-000

8-contact, 3D style LTM strip

1 8

9 10

105 mm

1 8

MS10R-IP10X-00010-contact, 3D style LTM strip

1 2 3 4 5 6 7 8

MS06R-IP10X-0006-contact, 3D style LTM strip

1 6

1 2 3 4 5 6

75 mm

1 4

2 3

55 mm

4

MS04R-IP10X-0004-contact, 3D style LTM strip

8.5 mm 1

1.5 mm375 mm10 mm

6 mm

90 mmTS08R-AP10X-0W6

8-contact, narrow-body LTM strip

1 8

1 6

70 mmTS06R-AP10X-0W6

6-contact, narrow-body LTM strip

10 mm

TS04R-AP10X-0W6 4-contact, narrow-body LTM strip

50 mm

Contact #1(typical) 375 mm

1 4

1.5 mm

Page 14: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

14

® MACRO/MICRO STRIP ELECTRODES

Catalog Number1 Description Macro Tail Cables2

QG20C-SP10X-000 20 contact macro-micro strip, 4 macro, 16 micro L-SRL-4DIN, L-RTL-4DIN or L-DCL-4DIN QG26A-SP10X-000 26 contact macro-micro strip, 6 macro, 20 micro L-SRL-6DIN, L-RTL-6DIN or L-DCL-6DIN QG36B-SP10X-000 36 contact macro-micro strip, 8 macro, 28 micro L-SRL-8DIN, L-RTL-8DIN or L-DCL-8DIN

� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

5 11 17

1915

137

9

6 12 18

2016

148

10

QG20C-SP10X-00020-contact, macro-micro strip

1 2 3 41 4

5 20

QG26A-SP10X-00026-contact, macro-micro strip

1 2 3 4 5 6

1

19

6

26

7 18

2324

11

17

1915

13

7

92622

21 25

12

18

2016

14

8

10

QG36B-SP10X-00036-contact, macro-micro strip

1 2 3 4 5 6 7 8

1

9

25

8

24

36

25 29 3326 30 34

13

19

2117

15

9

1128 32 3624

23 27 31 35

14

20

2218

16

10

12

Many cable options are available for the micro recording tails. Contact your Ad-Tech representative to dis-cuss these options.

1 - 38.1 Micron 2 - Tech-Attach cables require appropriate connector block

10 mm

8 mm

55 mm

75 mm

95 mm

� Manufactured with 50 or 38 Micron Platinum irridium wire� 4.0mm contact diameter� Numbered Platinum contacts � Thin and fl exible � Sterile; single-use only � 8 mm width ��Contact your Ad-Tech Representative for alternative designs or other special requirements ��Used with single tail passing needles � 37.5 cm tail length

0 0 8 6

Cables & Blocks

Page 15: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 15

10 mm

DS08A-SP10X-0008-contact, dual-sided LTM strip

DS12A-SP10X-00012-contact, dual-sided LTM strip

375 mm

75 mm

55 mm

Contact #8

Contact #1Contact #12

Side 1

Side 1

Side 2

Side 2

10 mm

1 12

1 82

2 2

Platinum marker

CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Cable Cable Cable Block Qty

DS08A-SP10X-000 1 x 4 dual L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)DS12A-SP10X-000 1 x 6 dual L-SRL-12BDIN L-RTL-12BDIN L-DCL-12BDIN DC-12X (1)DG20A-SP10X-U00 2 x 5 angled, dual L-SRL-20DIN L-RTL-20DIN L-DCL-20DIN DC-10X (2)DG32A-SP10X-V00 2 x 8 curved, dual L-SRL-32BDIN L-RTL-32BDIN L-DCL-32BDIN DC-16X (2)

1 Each electrode requires either the CABRIO, RoTec, or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

Side 2

Contact #32

2

25 mm

85 mm

10mm

10 mm

Contact #1

2

1

3 2

Contact #2

DG32A-SP10X-V0032-contact, dual-sided LTM grid

DG20A-SP10X-U0020-contact, dual-sided LTM grid

Contact #20

Side 1Side 2

End

0.9 mm

view 50 mm

10mm

20mm

10 mmPlatinum numbermarker (typical)

2 2

1

2 0

Contact #1

® EPILEPSY/LTM DUAL-SIDED INTERHEMISPHERIC SUBDURAL ELECTRODES� Mirror-imaged contacts on both sides of the electrode � Platinum & number markers as shown� Sterile; single-use only� Platinum contacts, 4.0 mm diameter with a 2.3 mm exposure

Electrodes areshown with the

exposed contactsurfaces facing

UP .

Contact #1

1.5 mm

2

Contact #2

Side 1

Page 16: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

16

® INTRAOPERATIVE MONITORING (IOM) SUBDURAL STRIP ELECTRODES

Contact CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Material Cable Cable Cable Block Qty

IS04R-SP10X-000 1 x 4 IOM strip platinum L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)

IS06R-SP10X-000 1 x 6 IOM strip platinum L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)

IS08R-SP10X-000 1 x 8 IOM strip platinum L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)

IS04R-SS10X-000 1 x 4 IOM strip stainless L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)

IS06R-SS10X-000 1 x 6 IOM strip stainless L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)

IS08R-SS10X-000 1 x 8 IOM strip stainless L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)

� Intraoperative monitoring electrodes feature numbered contacts, greater visibility of the recording surface and greater fl exibility of the electrode contact area

� Platinum or stainless steel numbered contacts, 4.0 mm diameter with a 2.3 mm exposure� Sterile; single-use only

Electrodes are shown with the

exposed contact surfaces facing

DOWN.

95 mmIS08R-SP10X-000 & IS08R-SS10X-000

8-contact IOM strip

1 2 3 4 5 6 7 8 1 8

75 mmIS06R-SP10X-000 & IS06R-SS10X-000

6-contact IOM strip

1 2 3 4 5 6

1 6

8 mm

55 mmIS04R-SP10X-000 & IS04R-SS10X-000

4-contact IOM strip

375 mm

1 2 3 4

End

0.7 mm

view

10 mm

1.5 mm

1 4

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

0 0 8 6

Cables & Blocks

Page 17: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 17

® IOM ELECTRODES WITH ATTACHED CABLES��6mm platinum or stainless steel indented contacts, 4 mm exposure, with 1.8 m attached cable� Sterile; single-use only� One-piece, easy to use

MS04N-IS10X-0JF 1 x 4 large, 3D style stainless steel strip with attached cableMS06N-IS10X-0JF 1 x 6 large, 3D style stainless steel strip with attached cableMS08N-IS10X-0JF 1 x 8 large, 3D style stainless steel strip with attached cable

1.5 mm safety socket

Connection Method

Catalog Number Description

MS04N-IP10X-0JF 1 x 4 large, 3D style platinum strip with attached cableMS06N-IP10X-0JF 1 x 6 large, 3D style platinum strip with attached cableMS08N-IP10X-0JF 1 x 8 large, 3D style platinum strip with attached cableFG08N-IP10X-0JF 2 x 4 large, 3D style platinum grid with attached cable

FG08N-IS10X-0JF 2 x 4 large, 3D style stainless steel grid with attached cable

MS04N-IP10X-0JF4-contact, IOM strip with attached cable

1 2 3 4

11.5 mm

2

3

4

MS04N-IS10X-0JF

8

MS08N-IP10X-0JF8-contact, IOM strip with attached cable

1 2 3 4 5 6 7 8

11.5 mm

2

3

4

5

6

7

MS08N-IS10X-0JF

MS06N-IP10X-0JF6-contact, IOM strip with attached cable

1 2 3 4 5 6

11.5 mm

2

3

4

5

6

MS06N-IS10X-0JF

cross-section view of 3D style contact

55 mm

75 mm

95 mm

8.5 mm

Page 18: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

18

� The intraoperative mapping electrode system provides an alternative design for intraoperative monitoring� Clover-leaf electrode shape stabilizes the electrode contact on the brain� Stainless steel numbered contacts, 6.0 mm diameter with 4.0 mm exposure, 3D style� Sterile; single-use only

Catalog Number Description

VG04A-IS00X-0KG 4-contact mapping electrode, numbered 1 - 4 VG04A-IS00X-0KH 4-contact mapping electrode, numbered 5 - 8

��VG-series electrodes do not require any additional cabling to interface with standard EP monitoring equipment.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

® INTRAOPERATIVE MAPPING ELECTRODE SYSTEM

Electrodes are shown with the exposed contact surfacesfacing DOWN.

VG04A-IS00X-0KG & VG04A-IS00X-0KH4-contact mapping electrode

175 m

m

2 m

1.5 mm safety socketMethod1

Connection

Pre-attached 1.5 mm safety sockets

1.2 mm

1.1 mm 15 mm

Stylet

2 m

CEDL-2PDINX-101 & CEDL-3PDINX-1002-contact spinal & 3-contact spinal (with stylet)

Placement Catalog Number Block Qty1CEDL-2PDINX-101 2-contact spinal electrode w/ pre-attached lead 16 ga. Tuohy Needle + stylet

® EPIDURAL SPINAL ELECTRODES

1.5 mm safety socketMethod1

Connection

120 dots 10 mm apart beginning 10 mm from #2 center. 100 mm mark should be a ring

CEDL-3PDINX-100 3-contact spinal electrode w/ pre-attached lead 16 ga. Tuohy Needle + stylet

� For intraoperative monitoring of evoked potential (EPs) of the descending pathway during spinal surgery� 2 or 3 platinum contacts� Sterile; single-use only� 16 gauge tuohy needle 0.044 inch/1.1176 mm in diameter� CEDL-Series electrodes do not require any additional cabling, 1.5 mm safety sockets attached� Attached 2 meter cable

0 0 8 6

Cables & Blocks

Page 19: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 19

No. of No. ofCatalog Number Description Macro Contacts Micro ContactsMM15A-SP05X-000 Kawasaki Macro-Micro Amygdala 6 9MM14A-SP05X-000 14 contact Macro-Micro depth 6 8MM01B-SP75X-000 28 contact Macro-Micro depth 4 24

� Contact your Ad-Tech rep for product details, alternative designs, and connection information.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

® EPILEPSY/LTM MACRO-MICRO DEPTH ELECTRODES��For simultaneous macro and micro recordings of the deep brain structures.� Sterile; single-use only� Platinum contacts

MM15A-SP05X-000

450 mm

MM01B-SP75X-000

370 mm

440 mm

Many cable options are available for the micro recording tails. Contact your Ad-Tech represen-tative to discuss these options.

MM14A-SP05X-000

38 Micron

50 Micron

38 Micron

1.3 mm

Page 20: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

20

0.04 mm

450 mmw/ 2 cm wires

from tipof Lumen

WB08R-SP00X-0008-contact micro-wire bundle(7 recording & 1 reference contacts)

Stylet

270 mm

Contact #1

BF08R-SP05X-0008-contact macro depth

8

® EPILEPSY/LTM BEHNKE FRIED DEPTH ELECTRODES� For simultaneous macro and micro contact recordings� 8-contact macro recording outer body with 8-contact micro recording inner wire bundle� Platinum contacts� Sterile; single-use only

1

Contact Contact TECH-ATTACH® ComponentsCatalog Number Description1 Size2 Spacing Cable Block

BF08R-SP05X-000 8-contact macro-depth 1.6/1.3 5.0 mm L-DCL-8DIN includedWB08R-SP00X-000 8-contact micro-depth 0.04 dia. N/A CLW-8DIN-264

(7 recording & 1 reference)

1 Each electrode requires the TECH-ATTACH or wire bundle cable as indicated. A special, slotted connector block that connects the macro contacts to the TECH-ATTACH cable is included with each BF-series electrode.

2 Overall length of the contact followed by its diameter (mm).3 Micro wires extend 2 cm past the tip; trim to desired length prior to use.4 Cable is 6 feet long and terminates in 1.5 mm safety socket.

Connection site for macro contacts

Connection site for micro contacts

Macro-Micro Electrode Shown Assembled

Close-up view ofmicro contacts3

1.3 mm 5.0 mm

1.6 mm

38 Micron

� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

0 0 8 6

Cables & Blocks

Page 21: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 21

1.0 mm

2.4 mm

5 mm

1 4

FO04K-SP05X-0004-contact FO; 5 mm spacing

® EPILEPSY/LTM FORAMEN OVALE ELECTRODES� For lateralizing/localizing the epileptic foci for the surgical treatment of epilepsy� One-piece body construction� 1.0 mm body diameter� Sterile; single-use only

� Includes two 17 gauge (0.04 inch/1.016 mm) needles for placement� Uses FO-style TECH-ATTACH connection systems� 2.4 mm long, platinum contacts

ConnectorsCatalog Number Description1 Cable Crimper

FD03K-SS05X-000 3-contact FO set, with 5mm contact spacing and introducing needles L-3-FODIN 712-N712-N Crimping tool. Used with all sphenoidal electrode kit or sets and/or with all foramen ovale electrodes with non-crimped connectors.

TECH-ATTACH® ComponentsCatalog Number Description1 Cable BlockFO04K-SP05X-000 4-contact FO set FO-LDC-4DIN includedFO06K-SP10X-000 6-contact FO set FO-LDC-6DIN included

� Stainless steel contacts� 0.50 mm body diameter� 2.0 mm long contacts

� Requires crimping of pins to electrode wire after placement� Sterile; single-use only

FD03K-SS05X-0003-contact FO; 5 mm spacing

300 mm

2.0 mm Connectorsrequire

crimping0.50 mm

5 mm1

2

3

300 mm10 mm

1

Contact #1

FO06K-SP10X-0006-contact FO; 10 mm spacing

6

711-LWKDINX Lead wire set. 6 feet (1.8 m) long. Includes one orange and one yellow wire. 1.5 mm safety sockets. Sterile; single-use only.

1 Each FO-series electrode set includes two foramen ovale electrodes, two 17 gauge (0.04 inch/1.016 mm diameter) introducing needles and two TECH-ATTACH connector blocks. Each set requires the cable indicated. Sterile; single-use only.

The FD03K-SS05X-000 electrode set includes two foramen ovale electrodes, eight pin connectors, two 18 gauge (0.036 inch/0.9144 mm diameter), introducing needles and two 19 gauge (0.03 inch/0.962 mm diameter) introducing needles. It requires the cable and crimper indicated.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

� Each set requires leadwire set

Page 22: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

22

® EPILEPSY/LTM SPENCER® PROBE DEPTH ELECTRODES� For monitoring/mapping subsurface levels of the brain during the surgical treatment of epilepsy� One-piece body construction� Platinum contacts

� Numbered label and 19 cm marker� Sterile; single-use only

10 mm

5 mm

Contact #1(typical)

390 mm

SD06R-SP05X-0006-contact depth; 5 mm spacing

SD06R-SP10X-0006-contact depth; 10 mm spacing

1

6

10 mm

5 mm

Stylet

1.5 mm

380 mm

SD04R-SP05X-0004-contact depth; 5 mm spacing

SD04R-SP10X-0004-contact depth; 10 mm spacing

141.1

mm

2.4 mm

400 mm

10 mm

5 mmSD08R-SP05X-0008-contact depth; 5 mm spacing

SD08R-SP10X-0008-contact depth; 10 mm spacing

1

8

� Colored band� Stay fl ange

Contact Body Contact CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number Description1 Size2 Diameter Spacing Cable Cable Cable Block Qty

SD04R-SP05X-000 4-contact depth 2.4/1.1 1.1 5 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)SD04R-SP10X-000 4-contact depth 2.4/1.1 1.1 10 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)SD06R-SP05X-000 6-contact depth 2.4/1.1 1.1 5 L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)SD06R-SP10X-000 6-contact depth 2.4/1.1 1.1 10 L-SRL-6DIN L-RTL-6DIN L-DCL-6DIN DC-6X (1)SD08R-SP05X-000 8-contact depth 2.4/1.1 1.1 5 L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)SD08R-SP10X-000 8-contact depth 2.4/1.1 1.1 10 L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.2 Overall length of the contact followed by its diameter (mm).� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

3 mm

17 mm

33 mm

27 mm

53 mm

37 mm

73 mm

0 0 8 6

Cables & Blocks

Page 23: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 23

® EPILEPSY/LTM SPENCER® PROBE DEPTH ELECTRODES

420 mm

5 mmSD12R-SP05X-00012-contact depth; 5 mm spacing

1

12

1.1 mm

2.4 mm

Contact Body Contact CABRIO® RoTec™ TECH-ATTACH® ComponentsCatalog Number1 Description Size2 Diameter Spacing Cable Cable Cable Block Qty

SD10R-SP05X-000 10-contact depth 2.4/1.1 1.1 5 L-SRL-10DIN L-RTL-10DIN L-DCL-10DIN DC-10X (1)SD12R-SP05X-000 12-contact depth 2.4/1.1 1.1 5 L-SRL-12BDIN L-RTL-12BDIN L-DCL-12BDIN DC-12X (1)MD01R-SP00X-000 1-contact depth 2.4/1.1 1.1 N/A N/A N/A 711-LWKDINX [6´ (1.8m) long]

AD04R-SP10X-000 4-contact AXIEM™ depth3,4 1.3/2.0 2.0 10 L-SRL-4DIN L-RTL-4DIN L-DCL-4DIN DC-4X (1)AD08R-SP05X-000 8-contact AXIEM™ depth3,4 1.3/2.0 2.0 5 L-SRL-8DIN L-RTL-8DIN L-DCL-8DIN DC-8X (1)

1 Each electrode requires either the CABRIO, RoTec or the TECH-ATTACH cable and the quantity of individual connector blocks as indicated.2 Overall length of the contact followed by its diameter (mm).3 AXIEM™ is a trademark of Medtronic.4 Pending mark approval.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

1.1 mm

MD01R-SP00X-0001-contact depth

2.4 mm

Connects to 711-LWKDINX lead wire

Stylet

330 mm

380 mm

10 mm

AD04R-SP10X-0004-contact, large diameter AXIEM™ depth; 10 mm spacing

AD08R-SP05X-0008-contact, large diameter AXIEM™ depth; 5 mm spacing

14

1

85 mm

2.0 mm

380 mm

1.3 mm

5 mmSD10R-SP05X-00010-contact depth; 5 mm spacing

1

10

410 mm

3 mm 48 mm

57.5 mm

Page 24: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

24

® DEPTH ELECTRODE PLACEMENT KITS

� Leksell Stereotactic System® & StealthStation® are registered trademarks of Elekta & Medtronic/Sofamor-Danek respectively. CRW™ and NaviVision™ are trademarks of Radionics & BrainLab.

� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

� For placement of depth electrodes with stereotactic or frameless systems

Catalog Number Description

DPK1-LEKN-PN Depth electrode placement kit - Leksell® frames. For use with passing needles (see p. 26). Non-sterile; reusable. Sterilize via autoclave. Includes guide blocks, drill sleeve guide, cannula sleeve guide, and ruler.

DPK1-LEKN-AB Depth electrode placement kit - Leksell® frames. For use with anchor bolts (see p. 26). Non-sterile; reusable. Sterilize via autoclave.

Drill sleeve guide -For Leksell® or CRW™30 cm ruler - For Leksell® or CRW™

Anchor bolt removal wrench - For Leksell® or CRW™ Cannula sleeve guide - For Leksell® or CRW™

DPK1-CRWN-PN Depth electrode placement kit - CRW™ frames. For use with passing needles (see p. 26). Non-sterile; reusable. Sterilize via autoclave. Includes guide blocks, drill sleeve guide, cannula sleeve guide, and ruler.

Guide blockCRW™ frames

Depth Electrode Placement Kits - for Leksell® or CRW™ Stereotactic System® Frames

Products to work with Medtronic StealthStation®

Catalog Number Catalog Number Usage

2SCK1-240X SNG-AX Sterile; reusable Resterilize via autoclave

Needle guide - StealthStation®Two-piece slotted cannula

Products to work with BrainLab Navigation™ System

Catalog Number Catalog Number Usage

2SCK1-240X BLNG-2X Sterile; reusable Resterilize via autoclave

Needle guide - NaviVision™Two-piece slotted cannula

240 mm

240 mm

2.11 mm

2.11 mm

Guide blocksLeksell® frames

Anchor bolt placement wrench withguide block for Leksell® or CRW™ frames

® DEPTH ELECTRODE CANNULAS

Catalog Number Description Diameter “D” Length “L” Units

2SCK1-190X Two-piece slotted cannula, sterile 2.11 mm 190 mm 2 Per Box2SCK1-240X Two-piece slotted cannula, sterile 2.11 mm 240 mm 2 Per BoxSCSG-90-2.18N Slotted Cannula sleeve guide, non-sterile 6.3 mm 90 mm

� For placement of depth electrodes with stereotactic or frameless systems� Reusable, resterilize via autoclave

Two-piece slotted cannulaCatalog No. 2SCK1-190X or 2SCK1-240X

“L”“D”

Cannula sleeve guideCatalog No. SCSG-90-2.18N

“D”

“L”

10 mm

DPK1-CRWN-AB Depth electrode placement kit - CRW™. For use with anchor bolts (see p. 26). Non-sterile; reusable. Sterilize via autoclave.

0 0 8 6

Anchor BoltsPassing NeedlesDisposable Drills

PlacementInstruments

� Guide tube accepts standard SD series depth electrodes only

Page 25: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 25

® DEPTH ELECTRODE ANCHOR BOLTS� For placement of depth electrodes with stereotactic or frameless systems� Sterile; single-use only

Catalog No. BABK1-LX

“D”

“L”

Catalog Number Diameter “D” Length “L” Units

BABK1-SX - Use with SD depth electrodes 2.7 - 4.7 mm taper 15 mm 3 Per BoxBABK1-MX - Use with SD depth electrodes 2.7 - 4.7 mm taper 21 mm 3 Per BoxBABK1-LX - Use with SD depth electrodes 2.7 - 4.7 mm taper 25 mm 3 Per Box LSBK1-AX-04 - Use with RD depth electrodes 2.5 mm 24 mm 3 Per BoxLSBK1-AX-05 - Use with SD depth electrodes 2.5 mm 24 mm 3 Per BoxLSBK1-AX-06 - Use with BF, LD or MM depth electrodes 2.5 mm 24 mm 3 Per BoxLSBK1-BX-04 - Use with RD depth electrodes 2.5 mm 14 mm 3 Per BoxLSBK1-BX-05 - Use with SD depth electrodes 2.5 mm 14 mm 3 Per BoxLSBK1-BX-06 - Use with BF, LD or MM depth electrodes 2.5 mm 14 mm 3 Per Box

� Made from titanium

® DISPOSABLE DRILL KITS� Includes two drills, two drills stop and two adjustment wrenches� For drilling cranial holes using a stereotactic frame � Stainless steel construction� Sterile, single-use only � 30 cm long

Bone drill & drill stop

Drill stop wrench

“D”“30 cm”

DDK2-2.8-30X 2.8 mm 2 Per BoxDDK2-3.2-30X 3.2 mm 2 Per Box

DDK2-2.4-30X 2.4 mm 2 Per Box

Catalog Number Diameter “D” Units

� Individually packaged, 3 per box

Page 26: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

26

® EPILEPSY/LTM SPHENOIDAL ELECTRODES� Supplied as kits (two electrodes, two introducing needles & two lead wires) � Two needle lengths available (2.0 inch & 2.75 inches long - 51 mm & 70 mm long)� 0.011 inch (0.28 mm) stainless steel or 0.007 inch (0.18 mm) platinum wire, 30 cm in length; un-insulated 3-4 mm tip� 21 gauge (0.033 inch/0.84 mm) needle; other introducing needles available upon request� Sterile; single-use only

Pre-crimped inter-connector pins

Pre-crimped connector

Wire loaded outside needle body

“L”

30 cm

1 Each sphenoidal electrode kit includes two sphenoidal electrodes, two 21 gauge introducing needles and two lead wires. Sterile; single-use only. � Manufactured in U.S.A. All dimensions are approximate. Drawings are not to scale. Consult price sheets for current pricing.

® PASSING NEEDLES� For tunneling the electrode wire carriers or “tails” away from the surgical site� Sterile; single-use only

� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

Single-tail passing needleCatalog No. LPNK1-10X

“L”

“D”

Passing needle - side viewshown with obturator removed

Passing needle - top viewshown with obturator inserted

Catalog No. APNK1-3.5X

“L”

Bent single-tail passing needleCatalog No. BPNK1-10X or BPN2K1-10X

15o

Catalog Number Description Diameter “D” Length “L” Units

APNK1-3.5X Passing needle 13 gauge (2.4 mm) 3.5 inch (8.9 cm) 5 Per BoxLPNK1-10X Single-tail passing needle 0.25 inch (6.4 mm) 10 inch (25.4 cm) 2 Per BoxBPNK1-10X Bent single-tail passing needle 0.25 inch (6.4 mm) 10 inch (25.4 cm) 2 Per BoxBPN2K1-10X Bent single-tail passing needle 0.20 inch (5.1 mm) 10.25 inch (26 cm) 2 Per Box

� LPNK1-10X and BPNK1-10X are for 3 or more tails. BPNK2-10X are for 2 tails.

Catalog Electrode Inter-Connector Wire Wire Needle lengthNumber Description1 Material Pin Style Location Diameter Dimension “L”

711-1DINX-01 Sphenoidal electrode kit stainless steel pre-crimped outside needle 0.011 in (0.28 mm) 2.75 in (70 mm)711-1DINX-05 Sphenoidal electrode kit stainless steel pre-crimped outside needle 0.011 in (0.28 mm) 2.00 in (51 mm)

711-1PDINX-01 Sphenoidal electrode kit platinum pre-crimped outside needle 0.007 in (0.18 mm) 2.75 in (70 mm)711-1PDINX-05 Sphenoidal electrode kit platinum pre-crimped outside needle 0.007 in (0.18 mm) 2.00 in (51 mm)

0 0 8 6

Cables & Blocks

Page 27: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 27

® ELECTRODE CABLE SPLITTER BOX

Catalog Number DescriptionCLW-32DIN-CSB 32-channel electrode cable splitter box with cables� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

� Ad-Tech’s new cable splitter box accepts up to 32 channels of input and then splits the signal into two separate 32 channels of output

� Includes input sockets for references and grounds� Uses standard 1.5 mm female connectors (inputs & outputs)

® SUBPIAL TRANSECTORS� Lightweight & disposable� Two different 0.55 mm diameter tip styles (dull & sharp)� Sterile; single-use only

* Ad-Tech’s Subpial Transectors are NOT CE Marked

CatalogNumber Description1

MST-D03X MST handle with pre-attached dull tip. Box of three individually sterilized units.MST-S03X MST handle with pre-attached sharp tip. Box of three individually sterilized units.1 All tips have a wire diameter of 0.55 mm. The bent distal portion of all tips is approximately 5 mm long. Sterile; single-use only.

3 14 5 6 7 8

9 10 11 112 13 14 15 16

17 18 19 120 21 22 23 24

25 26 27 128 29 30 31 32

REF

GND

A

REF

GND

B

REF

GND

INPUT

OUTPUT

OUTPUT1 2

1.8 m

1.8 m

Attached cableAttached cable

Sharp tip

MST-S03X

®

Dull tip

MST-D03X

®

Page 28: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

28

® LIGHTWEIGHT ELECTRODE CONNECTION SYSTEMS� Lightweight and Flexible

®

Lightweight CABRIO Connection System

Catalog Terminal Dimension Cable DiameterNumber Description1 Confi guration “L” “A”

L-SRL-4DIN 4-contact lightweight CABRIO connector/cable 1 terminal of 4 34 mm 2.21 mmL-SRL-6DIN 6-contact lightweight CABRIO connector/cable 1 terminal of 6 44 mm 2.67 mmL-SRL-8DIN 8-contact lightweight CABRIO connector/cable 1 terminal of 8 54 mm 2.67 mmL-SRL-10DIN 10-contact lightweight CABRIO connector/cable 1 terminal of 10 64 mm 3.23 mmL-SRL-12BDIN 12-contact lightweight CABRIO connector/cable 1 terminal of 12 94 mm 3.76 mmL-SRL-16BDIN 16-contact lightweight CABRIO connector/cable 1 terminal of 16 94 mm 3.76 mmL-SRL-20DIN 20-contact lightweight CABRIO connector/cable 2 terminals of 10 64 mm 2 x 3.23 mmL-SRL-32BDIN 32-contact lightweight CABRIO connector/cable 2 terminals of 16 94 mm 2 x 3.76 mmL-SRL-48BDIN 48-contact lightweight CABRIO connector/cable 3 terminals of 16 94 mm 3 x 3.76 mmL-SRL-64BDIN 64-contact lightweight CABRIO connector/cable 4 terminals of 16 94 mm 4 x 3.76 mm

CABRIOCABRIOCABRIOConnection System

14 mm

Side view

Pivot

“L” Terminal block(transparent)

Lightweight cable

1.8 m

12.5 mm

Connector body(blue)

1.5 mm safety (DIN) socket

1.5 mm

35 mm“A”

Lightweight RoTec Connection System

Catalog Terminal Dimension Cable DiameterNumber Description1 Confi guration “L” “A”

L-RTL-4DIN 4-contact lightweight RoTec connector/cable 1 terminal of 4 35 mm 2.21 mmL-RTL-6DIN 6-contact lightweight RoTec connector/cable 1 terminal of 6 35 mm 2.67 mmL-RTL-8DIN 8-contact lightweight RoTec connector/cable 1 terminal of 8 45 mm 2.67 mmL-RTL-10DIN 10-contact lightweight RoTec connector/cable 1 terminal of 10 55 mm 3.23 mmL-RTL-12BDIN 12-contact lightweight RoTec connector/cable 1 terminal of 12 65 mm 3.76 mmL-RTL-16BDIN 16-contact lightweight RoTec connector/cable 1 terminal of 16 85 mm 3.76 mmL-RTL-20DIN 20-contact lightweight RoTec connector/cable 2 terminals of 10 55 mm 2 x 3.23 mmL-RTL-32BDIN 32-contact lightweight RoTec connector/cable 2 terminals of 16 85 mm 2 x 3.76 mmL-RTL-48BDIN 48-contact lightweight RoTec connector/cable 3 terminals of 16 85 mm 3 x 3.76 mmL-RTL-64BDIN 64-contact lightweight RoTec connector/cable 4 terminals of 16 85 mm 4 x 3.76 mm

Connection System

1.5 mm safety (DIN) socket

1.5 mm

Lightweight cable

“A” 35 mm

Connector body(Blue)

Terminal block(transparent)

� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

� Lightweight Cabrio, RoTec and TECH-ATTACH cables are supplied with 1.5 mm safety sockets. Where not prohibited by law, alternative termination options are available upon request. Non-sterile; sterilize via EtO (EO) or Sterrad.

“L”

15 mm

� 1.8 m (6 feet) length - additional cable lengths available� Quick disconnect option available

Copyright @d-Tech Medical 2011

Cables & Blocks

Page 29: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 29

Lightweight TECH-ATTACH Connection System

Catalog Terminal Dimension Cable Diameter Number2 Description1 Confi guration “L” “A”

L-DCL-4DIN 4-contact lightweight TECH-ATTACH cable 1 terminal of 4 34 mm 2.21 mm L-DCL-6DIN 6-contact lightweight TECH-ATTACH cable 1 terminal of 6 44 mm 2.67 mm L-DCL-8DIN 8-contact lightweight TECH-ATTACH cable 1 terminal of 8 54 mm 2.67 mm L-DCL-10DIN 10-contact lightweight TECH-ATTACH cable 1 terminal of 10 64 mm 3.23 mm L-DCL-12BDIN 12-contact lightweight TECH-ATTACH cable 1 terminal of 12 66 mm 3.76 mm L-DCL-16BDIN 16-contact lightweight TECH-ATTACH cable 1 terminal of 16 94 mm 3.76 mm L-DCL-20DIN 20-contact lightweight TECH-ATTACH cable 2 terminals of 10 64 mm 2 x 3.23 mm L-DCL-32BDIN 32-contact lightweight TECH-ATTACH cable 2 terminals of 16 94 mm 2 x 3.76 mm L-DCL-48BDIN 48-contact lightweight TECH-ATTACH cable 3 terminals of 16 94 mm 3 x 3.76 mm L-DCL-64BDIN 64-contact lightweight TECH-ATTACH cable 4 terminals of 16 94 mm 4 x 3.76 mm

Connection System

Cable1.8 m

1.5 mm safety (DIN) socket

35 mm

Lightweight cable

“A”

“L”

1.5 mm

®

�Lightweight CABRIO and TECH-ATTACH cables are supplied with 1.5 mm safety sockets. Where not prohibited by law, alternative termination options are available upon request. Non-sterile; sterilize via EtO (EO) or Sterrad.� All lightweight TECH-ATTACH cables require the use of disposable connector blocks. �Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

TECH-ATTACH Disposable Connector Blocks (Box of 10)

CatalogNumber Description Used with Lightweight TECH-ATTACH Cable DC-2X 2-contact block L-DCL-2DINDC-3X 3-contact block L-DCL-3DINDC-4X 4-contact block L-DCL-4DIN DC-5X 5-contact block L-DCL-5DINDC-6X 6-contact block L-DCL-6DIN DC-8X 8-contact block L-DCL-8DIN, -16DIN, -32DIN, -48DIN & -64DIN DC-10X 10-contact block L-DCL-10DIN, -20DIN & -40BDIN DC-11X 11-contact block L-DCL-35DINDC-12X 12-contact block L-DCL-12BDIN, -24BDIN, -35DIN & -48DDIN DC-16X 16-contact block L-DCL-16BDIN, -32BDIN, -48BDIN & -64BDIN

® DISPOSABLE CONNECTOR BLOCKS� Disposable, sterile

��All TECH-ATTACH connector blocks are packaged in sets of two with fi ve sets per box. Sold by box of ten only. Sterile; single-use only.� Manufactured in U.S.A. All dimensions are approximate. All drawings are not to scale. Consult price sheets for current pricing.

Page 30: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

30

BRAIN BIOPSY NEEDLE GUIDES� For guiding brain biopsy needles using stereotactic or frameless systems� High quality & low cost

Catalog Number Units Description

11980 1 Per Box DAPII brain biopsy needle guide housing. Requires a guide sphere assembly (see below). Screw mount. Placed through a standard 1.0 - 1.5 cm burr hole. Non-sterile; sterilize via autoclave.

11980-02X 2 Per Box Guide sphere assembly. Used with biopsy needles without barium sleeves. Sterile; single-use only.

11980-PW 1 Per Box Placement wrench. Used to insert or remove the DAPII needle guide. Non-sterile; sterilize via autoclave.

*Most Common*Catalog Number Catalog Number Catalog Number Dimension2

“A” = 8 mm “A” = 5 mm “A” = 10 mm Material “L” Units

DBN-08-10X stainless steel 10 cm 1 Per BoxDBN-08-19X DBN-05-19X stainless steel 19 cm 1 Per BoxDBN-08-24X DBN-10-24X stainless steel 24 cm 1 Per BoxMDBN-08-10X MR-conditional 1 10 cm 1 Per BoxMDBN-08-15X MR-conditional 1 15 cm 1 Per BoxMDBN-08-19X MR-conditional 1 19 cm 1 Per Box

® DISPOSABLE BRAIN BIOPSY NEEDLES� Supplied as complete kits (needle, needle stop & aspirator tube with Luer lock; 10 cm models also include a barium sleeve)� Available in standard lengths: 10 cm, 15 cm, 19 cm & 24 cm (custom lengths available)� Inner and outer cannula have polished, rounded closed ends � 14 gauge (0.083 inch/2.11 mm) diameter � Sterile; single-use only� Nominal 5, 8 or 10 mm side cutting window � 304 stainless steel with 1 cm markings� Also available in MR-conditional materials� � For stereotactic-guided procedures� High quality & low cost

1 Contact your Ad-Tech representative for specifi c MR-conditional parameters.2 All reducing guide kits needles are 12 gauge (0.109 inch/2.77 mm) in diameter; with an inner diameter of 0.083 inch/2.11 mm. All other dimensions are as stated.� Manufactured in U.S.A. All dimensions are approximate. Drawings are not to scale. Consult price sheets for current pricing.

Sphere lock

Needle lock

Needle stop

Biopsy needle shown with DAPII needle guide

Needle guidehousing

Guide sphere assembly

� For use with CRW™ stereotactic framesCatalog Number Description2 Length “L” Kit Contents Usage

DRGK1-76-5X Disposable reducing guide kit 76 mm Box of 5 Sterile; single-use onlyDRGK1-116-5X Disposable reducing guide kit 116 mm Box of 5 Sterile; single-use only DRGK1-160-5X Disposable reducing guide kit 160 mm Box of 5 Sterile; single-use only

DISPOSABLE REDUCING GUIDE KITS “L”

Catalog No. DRGK1-76-5X

Catalog No. DRGK1-116-5X

Catalog No. DRGK1-160-5X

“A” 2.11 mm

Cutting edges

CL

Indication arrows aligned:Cutting window is open

End View

Needle stop

“L”

0 0 8 6

Needle Guides &Accessories

Page 31: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 31

CatalogNumber Units Description

CNE1-2KDINX 2 Per Box 2 mm cranial nerve electrode kit

Middle fossa electrode

Recording side

Non-recording side

280 mm

250 mm

Applicator wand

Cueva cranial nerve electrode

® CUEVA INTRAOPERATIVE CRANIAL NERVE ELECTRODES� For direct cranial nerve monitoring during skull base surgeries� Circumferential design, 2.0mm or 3.0mm diameter “C-Shaped” electrode� Supplied in complete sterile kits� Platinum contacts� Easy-to-use applicator, 250 mm long� Highly-consistent amplitude; real-time status� 2.35 mm diameter platinum contact electrode (for the middle fossa approach)� Sterile; single-use only

Cranial nerve electrode lead wire(EEG interface cable)

� Manufactured in U.S.A. All dimensions are approximate. Drawings are not to scale. Consult price sheets for current pricing.

��Each cranial nerve electrode kit includes two 2.0 mm or 3.0 mm cranial nerve electrodes, one 25 cm long applicator wand, and one 6 foot (1.8 m) lead wire terminating in a 1.5 mm safety socket. Sterile; single-use only.

��Each middle fossa electrode kit includes two electrodes, and two 6 foot (1.8 m) lead wires terminating in a 1.5 mm safety socket. Sterile; single-use only. ��All lead wires are 6 feet (1.8 m) long. All lead wires interface with standard EEG/EP amplifi ers using 1.5 mm safety sockets.

CNE1-1SKDINX 2 Per Box Middle fossa electrode kit CNE1-3KDINX 2 Per Box 3 mm cranial nerve electrode kit

* Ad-Tech’s Cranial Nerve Electrodes are NOT CE Marked

Page 32: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

32

® IVES CT COMPATIBLE, NON-FERROUS ELECTRODES� Conductive plastic cup bodies with a low-noise Ag-AgCl coating� Completely non-ferrous� CT compatible� Standard 10 mm diameter cups� Color and length coded wires conform to 10:20 system� Easy connection to harness� Collodion3 for long-term use� Non-sterile; reusable

* Ad-Tech’s Ives CT Compatible, Non-Ferrous Electrodes are NOT CE Marked

Dimension Leadwire LengthCatalog Number Description Material Diameter “L”

IES-CPE-20N 20-contact conductive plastic electrode set1 ABS plastic body 10 mm 15 - 28 cm Ag-AgCl coatingIES-HAR-20N 20-contact EEG interface harness2 1.2 m1 Each conductive plastic electrode set includes one red and one green, color-and length-coded, labeled 10-channel electrode assembly and two replacement (spare) EEG

electrode disks and wires. Non-Sterile; not intended for sterilization, Reusable.2 Each EEG interface harness includes one red and one green, color-coded and labeled 10-channel harness assembly. Non-Sterile; not intended for sterilization, Reusable.3 Use non acetone for removing electrodes.

IES-CPE-20N Conductive Plastic Electrode SetElectrode Placement - 10:20 System

IES-CPE-20N Conductive Plastic Electrode Set& IES-HAR-20N EEG Interface Harness

Actual recording obtained from using the IES-CPE-20N Conductive Plastic Electrode Set

14mm

ElectrodeDisks

10mm

10-Pin FemaleConnector“L” min.

“L” max.

IES-CPE-20N Conductive Plastic Electrode Set

13mm

25mm

IES-HAR-20N EEG Interface Harness

10-Pin MaleConnector

1.5 mm safety (DIN) socket

1.2 m

35 mm

1.5mm

Page 33: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

®

® Telephone: 262.634.1555 [email protected] Toll Free (USA): 800.776.1555 www.adtechmedical.com 33

® IVES SUBDERMAL WIRE ELECTRODES� Silver wire electrodes with a low-noise Ag-AgCl coating� Completely non-ferrous� 25-gauge introducing needles� Color-and length-coded wires conform to 10:20 system� Easy connection to harness� Non-sterile; single-use only

* Ad-Tech’s Ives Subdermal Wire Electrodes are NOT CE Marked

Dimension LengthCatalog Number Description Material Diameter “L”

IES-SWE-10N 10-contact subdermal wire electrode set1 Ag-AgCl wire 0.25 mm 4.5 cmIES-ADT-10N 10-contact adapter kit2 25 gauge 12 - 23 cmIES-HAR-10N 10-contact EEG interface harness3 1.2 m1 Each subdermal wire electrode set includes ten Ag-AgCl wire electrodes, ten introducing needles, and ten needle sheaths. Non-Sterile; sterilize via EtO, Disposable.

Single-Use Only.2 Each adapter kit includes one color- and length-coded, labeled 10-channel electrode assembly. Non-Sterile; not intended for sterilization, Reusable.3 Each EEG interface harness includes one color-coded and labeled 10-channel harness assembly. Non-Sterile; not intended for sterilization, Reusable.� Contact your @D-TECH representative for information on MR testing.

IES-SWE-10N Subdermal Wire Electrode Set

Shown As Supplied(Qty = 10)

Needle Sheath

Electrode

Placement Needle

ComponentsIES-SWE-10N Subdermal Wire Electrode Set& IES-ADT-10N Adapter Kit

Mid

line

Righ

t Sid

eLe

ft Si

de

ElectrodeConnector Pin

1.5 mm safety (DIN) socket

1.2 m

35 mm

10-Pin FemaleConnector“L” min.

“L” max.

45mm

IES-ADT-10N Adapter Kit

13 mm

14mm

1.5mm

IES-HAR-10N EEG Interface Harness

10-Pin MaleConnector

IES-SWE-10NConductive Subdermal Wire Electrode Set

ElectrodeConnector Socket

25mm

IES-SWE-10N Subdermal Wire Electrode SetIES-ADT-10N Adapter Kit

& IES-HAR-10N EEG Interface Harness

Page 34: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP

34

NOTES

ITEMS REGULARLY ORDERED:

Page 35: AdTech ProductCatalog Final2 -  · PDF fileTelephone: 262.634.1555 ® sales@adtechmedical.com Toll Free (USA): 800.776.1555   7 ® EPILEPSY/LTM MULTI-STRIP