ADDM. NO. CC-1-1 ADDENDUM NO. CC-1 . to the PROJECT MANUAL AND DRAWINGS for SOUTHEASTERN COMMUNITY COLLEGE – BUILDING 100 INTERIOR RENOVATIONS SOUTHEASTERN COMMUNITY COLLEGE WEST BURLINGTON, IA DLR GROUP PROJECT NO. 11-14110-70 March 27, 2017 NOTICE TO BIDDERS: The Project Manual and Drawings for the above referenced project are hereby amended as follows: CLARIFICATION The following clarification note should be referred to for all project manuals and project drawings: Clarification: It is the Contractor’s responsibility to see that he has all pertinent information for bidding this project. Because of mass production of the Project Manuals and Drawings, there may be some misplaced or missing pages in the manuals. Should a page or pages be missing from the manuals, please notify DLR Group and those pages will be supplied at no additional charge.” PROJECT MANUAL –VOLUME 1 ITEM NO. 1 DOCUEMNT 004113 – BID FORM – STIPULATED SUM (SINGLE-PRIME CONTRACT) A. Delete Bid Form in its entirety and substitute new Bid Form per Attachment No. 1. ITEM NO. 2 DOCUEMNT 006000 – FORMS B. Attachment – AIA A201, “General and Supplementary Conditions of the Contract for Construction. 1. Clause 9.11.1.1. Delete the word “staring” and replace with “starting” 2. Clause 9.11.1.2. Delete the word “staring” and replace with “starting” ITEM NO. 3 SECTION 011000 – SUMMARY A. Paragraph 11.1.B. Delete paragraph in its entirety, subparagraph 11.1.B.1 to remain, and replace with the following: “ B. On-Site Work Hours: Limit work in the existing building to non-business hours of 5:00 p.m. to 7:00 a.m., Monday through Friday, when disruptive to Owner’s activities. Non-disruptive construction activities can take place from 7:00 a.m. to 5:00 p.m., Monday thru Friday, with Owner’s approval.” ITEM NO. 4 SECTION 012300 – ALTERNATES A. Paragraph 3.1.B. Delete paragraph in its entirety. Architecture Engineering Planning Interiors 1430 Locust Street Suite 200 Des Moines, IA 50309 tel 515/276-8097 www.dlrgroup.com
17

Addm CC-1_BLDG 100_FINAL.pdf

Apr 23, 2023

Download

Documents

Khang Minh
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Addm CC-1_BLDG 100_FINAL.pdf

ADDM. NO. CC-1-1

ADDENDUM NO. CC-1 .

to the

PROJECT MANUAL

AND

DRAWINGS

for

SOUTHEASTERN COMMUNITY COLLEGE – BUILDING 100 INTERIOR RENOVATIONS

SOUTHEASTERN COMMUNITY COLLEGE

WEST BURLINGTON, IA

DLR GROUP PROJECT NO. 11-14110-70 March 27, 2017

NOTICE TO BIDDERS: The Project Manual and Drawings for the above referenced project are hereby amended

as follows:

CLARIFICATION

The following clarification note should be referred to for all project manuals and project drawings:

“ Clarification: It is the Contractor’s responsibility to see that he has all pertinent information for bidding

this project. Because of mass production of the Project Manuals and Drawings, there may be some

misplaced or missing pages in the manuals. Should a page or pages be missing from the manuals, please

notify DLR Group and those pages will be supplied at no additional charge.”

PROJECT MANUAL –VOLUME 1

ITEM NO. 1 DOCUEMNT 004113 – BID FORM – STIPULATED SUM (SINGLE-PRIME CONTRACT)

A. Delete Bid Form in its entirety and substitute new Bid Form per Attachment No. 1.

ITEM NO. 2 DOCUEMNT 006000 – FORMS

B. Attachment – AIA A201, “General and Supplementary Conditions of the Contract for Construction.

1. Clause 9.11.1.1. Delete the word “staring” and replace with “starting”

2. Clause 9.11.1.2. Delete the word “staring” and replace with “starting”

ITEM NO. 3 SECTION 011000 – SUMMARY

A. Paragraph 11.1.B. Delete paragraph in its entirety, subparagraph 11.1.B.1 to remain, and replace with the

following:

“ B. On-Site Work Hours: Limit work in the existing building to non-business hours of 5:00 p.m. to

7:00 a.m., Monday through Friday, when disruptive to Owner’s activities. Non-disruptive

construction activities can take place from 7:00 a.m. to 5:00 p.m., Monday thru Friday, with

Owner’s approval.”

ITEM NO. 4 SECTION 012300 – ALTERNATES

A. Paragraph 3.1.B. Delete paragraph in its entirety.

Architecture Engineering Planning Interiors

1430 Locust Street Suite 200

Des Moines, IA 50309

tel 515/276-8097

www.dlrgroup.com

Page 2: Addm CC-1_BLDG 100_FINAL.pdf

ADDM. NO. CC-1-2

DRAWINGS

ITEM NO. 1 SHEET 0.1 – SYMBOLS AND ABBREVIATIONS

A. General Notes.

1. Note 17 – Revise to “Plan symbol indicates wall type – see sheet A1.1 for description of wall types.

All new wall types are S1, unless noted otherwise on plans” in lieu of “Plan symbol indicates wall

type – See sheet A1.1 for description of wall types”.

ITEM NO. 2 SHEET AD1.1 – DEMOLITION FLOOR/CEILING PLANS

A. Replace sheet in its entirety with attached sheet AD1.1 – DEMOLITION FLOOR/CEILING PLANS

ITEM NO. 3 SHEET CP1.1 – CODE PLAN/PHASING PLAN

A. Replace sheet in its entirety with attached sheet CP1.1 – CODE PLAN/PHASING PLAN

ITEM NO. 4 SHEET A0.1 – ROOM FINISH PLAN AND ELEVATIONS

A. Replace sheet in its entirety with attached sheet A0.1 – ROOM FINISH PLAN AND ELEVATIONS.

ITEM NO. 5 SHEET A0.2 – ELEVATIONS AND ROOM SCHEDULE

A. Add new sheet A0.2 – ELEVATIONS AND ROOM FINISH SCHEDULE, attached.

ITEM NO. 6 SHEET A1.1 – FLOOR PLAN

1. Replace sheet in its entirety with attached sheet A1.1 – FLOOR PLAN.

ITEM NO. 7 SHEET A3.1 – REFLECTED CEILING, FIRST LEVEL – AREA A

A. Replace sheet in its entirety with attached sheet A3.1 – REFLECTED CEILING PLAN, FIRST LEVEL –

AREA A.

ITEM NO. 8 SHEET A9.1 – DOOR AND FRAME SCHEDULE

1. Replace sheet in its entirety with attached sheet A9.1 – DOOR AND FRAME SCHEDULE.

ITEM NO. 9 SHEET MD1.1 – MECHANICAL DEMOLITION, FIRST LEVEL – AREA A

A. DEMO HVAC PLAN KEYED NOTES.

1. NOTE 6. Delete this note in its entirety. Replace with the following:

“6. REMOVE EXISTING FINNED TUBE RADIATOR AND REINSTALL AS NOTED.”

2. NOTE 9. Delete this note in its entirety. Replace with the following:

“9. TESTING AND BALANCING TO BE COMPLETED BY OWNER. REMOVE EXISTING

SUPPLY DIFFUSER AND REINSTALL AS NOTED. DEMOLISH EXISTING FLEX DUCT AND

DUCT TIE IN. PATCH AND SEAL EXISTING SUPPLY AIR MAIN AND PREPARE FOR NEW

WORK.”

Page 3: Addm CC-1_BLDG 100_FINAL.pdf

ADDM. NO. CC-1-3

ITEM NO. 10 SHEET E0.0 – ELECTRICAL SYMBOLS AND ABBREVIATIONS

A. General Systems Notes (Division 27 Work). Note 3. Delete reference to “PATCH CABLES” in Note 3.

(Patch cords shall be included in this contract under Division 27.)

ITEM NO. 11 SHEET ED1.1 – ELECTRICAL DEMOLITION PLAN, FIRST LEVEL – AREA A

A. Modify sheet as shown on attachment ED1.1, dated March 27, 2017.

ITEM NO. 12 SHEET E1.1 – LIGHTING PLAN, FIRST LEVEL – AREA A

A. Add Note 2 to “DL1” fixture in corridor outside of Enrollment Services 301.

ITEM NO. 13 SHEET E2.1 – POWER PLAN, FIRST LEVEL – AREA A

A. Modify sheet as shown on attachment E2.1, dated March 27, 2017.

ITEM NO. 14 SHEET E3.1 – SPECIAL SYSTEMS PLAN, FIRST LEVEL – AREA A

A. Modify sheet as shown on attachment E3.1, dated March 27, 2017.

ITEM NO. 15 SHEET E4.1 – ELECTRICAL SCHEDULES AND DETAILS

A. Modify sheet as shown on attachment E4.1, dated March 27, 2017.

END OF ADDENDUM NO. CC-1

Page 4: Addm CC-1_BLDG 100_FINAL.pdf

BUILDING 100 – INTERIOR RENOVATIONS 11-14110-70 SOUTHEASTERN COMMUNITY COLLEGE WEST BURLINGTON, IOWA BID SET

BID FORM - STIPULATED SUM (SINGLE-PRIME CONTRACT) 004113-1 Attachment No. 1

to Addendum No. CC-1

dated March 27, 2017

SECTION 004113 - BID FORM-STIPULATED SUM (SINGLE-PRIME CONTRACT)

Hall of Sciences Southeastern Community College West Burlington, Iowa Project No. 11-14110-30 Issue Date: March 9, 2017

Bid of ,

o a corporation organized and existing under the laws of the State of Iowa;

o a corporation organized and existing under the laws of the State of ________________________

and is/is not licensed to do business in the State of Iowa as a foreign corporation;

o a partnership consisting of _____________________________________________ , partners; or

o a sole proprietor;

hereinafter called the Bidder.

To: Board of Trustees Southeastern Community College 1500 West Agency Road West Burlington, Iowa 52655

The undersigned acknowledges that he has received and familiarized himself with the following:

Project Manual: Divisions and Sections, as listed by Table of Contents

Drawings: As listed by the sheet index.

Addenda: No. _____________ Dated _______________

No. _____________ Dated _______________

No. _____________ Dated _______________

No. _____________ Dated _______________

No. _____________ Dated _______________

Page 5: Addm CC-1_BLDG 100_FINAL.pdf

BUILDING 100 – INTERIOR RENOVATIONS 11-14110-70 SOUTHEASTERN COMMUNITY COLLEGE WEST BURLINGTON, IOWA BID SET

BID FORM - STIPULATED SUM (SINGLE-PRIME CONTRACT) 004113-2 Attachment No. 1

to Addendum No. CC-1

dated March 27, 2017

The undersigned further acknowledges that he has visited the site and familiarized himself with local conditions affecting the cost of the Work at the place where the Work is to be done.

In submitting this Bid, the undersigned agrees:

1. To furnish all material, labor, tools, expendable equipment, and all utility and transportation services necessary to provide and complete, in a workmanlike manner, all of the Work required for the Building 100 – Interior Renovations Contract in accord with the Bidding Documents prepared by DLR Group inc., for the consideration hereinafter set forth.

2. To hold his Bid open for thirty (30) days after the receipt of Bids and to accept the provisions of the Instructions to Bidders regarding disposition of Bid Security.

3. To enter into and execute a Contract if awarded on the basis of this Bid, to furnish a Performance Bond and a Labor and Material Payment Bond in accord with the General Conditions and General Requirements of this Contract, and to deliver executed Owner-Contractor Agreements and Bonds to the Architect-Engineer within ten (10) days after notification of award, for submittal to the Owner for his approval and acceptance.

4. To substantially complete the Work as specified in Section 011000 “Summary.”

LUMP SUM BASE BID: The undersigned hereby proposes and agrees to provide the foregoing for the Lump Sum of

dollars ($ ). (Amount shall be shown in both words and figures. In case of discrepancy, the amount shown in words will govern.)

ALTERNATES: The above Lump Sum Base Bid may be modified in accord with the following Alternates, which may be accepted by the Owner:

ALTERNATE NO. CC-1: Provide material and labor to add the renovation work required for the Business Office area as indicated on drawings and as specified.

If this Alternate is accepted, add to the Lump Sum Base Bid the sum of

dollars ($ ).

Page 6: Addm CC-1_BLDG 100_FINAL.pdf

BUILDING 100 – INTERIOR RENOVATIONS 11-14110-70 SOUTHEASTERN COMMUNITY COLLEGE WEST BURLINGTON, IOWA BID SET

BID FORM - STIPULATED SUM (SINGLE-PRIME CONTRACT) 004113-3 Attachment No. 1

to Addendum No. CC-1

dated March 27, 2017

The undersigned has attached the required Bid Security and other items required in the Instructions to Bidders.

In submitting this Bid, it is understood that the right to reject any and all Bids and to waive irregularities in the bidding has been reserved by the Owner.

Dated this _____________________________________ day of ________________________, 20_____

________________________________________________ Name of Bidder

________________________________________________ Address of Bidder

________________________________________________ Authorized Officer

________________________________________________ Area Code/Telephone Number

END OF DOCUMENT 004113

Page 7: Addm CC-1_BLDG 100_FINAL.pdf

EXISTING TO REMAIN

EXISTING TO REMAIN

22

1

14

2

5

6

4

2

3

2

7

2

2

2

2

2 2

1

2

2

1

22

1222222

18

SUPPORTCENTER

101

TESTING/DISABILITY

106

RECEPTION

105

HI-SET TESTING

104

ADMIN. ASST.

114

V.P. OFSTUDENTSERVICES

113TESTING

107

ADVOCATE

112

TEST./DISABILITY

108

STOR

109

CORR

102

CORR

103

VOC. REHAB

111

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR

110

2

PAYROLL

205

CONTROLLER

204

PURCHASINGAGENT

203

BUSINESSOFFICE

201

ACCOUNTANT

202

OFFICE

302 OFFICE

303

OFFICE

304

STOR

305

OFFICE

206

OFFICE

307

OFFICE

309

OFFICE

310

CONFERENCE

312

OFFICE

313

OFFICE

314

OFFICE

315

OFFICE

316

OFFICE

317

ENROLLMENTSERVICES

301

STOR

308

1

WORK IN BUSINESS OFFICE ISPART OF ALTERNATE NO. CC-01

31170

282

14

170

14

36

A1.1

28340

170

27

170

15

1-C

1-C1-

C1-C

1-C

1-C

1-C

1-C

1-C

1-C

1-C 1-C

1-C1-C

1-C

1-C

1-C

1-C

1-C

1-C

1-C

1-C

2-FB

2-FB

2-F

B

2-FB

2-F

B

2-FB

2-F

B

2-FB2-FB

FE

FE

FE

FE

EXISTING GWB ON WESTSIDE OF WALL EXTENDS 6"ABOVE EXISTING CEILING.INSTALL NEW GWB UP TO

EXISTING DECK TO THENORTH OF EXISTING 2-FBWALL TO THE EXTEND OF

DIMENSION SHOWN. TIE INTO NEW 2-FB WALL EXTEND

ING EAST.

10' -

10

3/8" 31

CP1.1

- COMBINED OCCUPANT LOAD AT A GIVEN EXIT DOOR. (SUM OF THESE EQUALS TOTAL OCCUPANT LOAD)

(THE CAPACITY OF DOORS ARE DETERMINED AS FOLLOWS:CLEAR OPENING WIDTH IN INCHES DIVIDED BY 0.2THE CAPACITY OF STAIRS ARE DETERMINED AS FOLLOWS:WIDTH IN INCHES DIVIDED BY 0.3)

- COMBINED OCCUPANT LOAD AT A GIVEN DOOR OR STAIR

- TOTAL EXIT CAPACITY OF DOOR(THE CAPACITY OF DOORS ARE DETERMINED AS FOLLOWS:CLEAR OPENING WIDTH IN INCHES DIVIDED BY 0.2)

WALL SEPARATION LEGEND

SYMBOL LEGEND

- OCCUPANCY LOAD####

0

0 - TOTAL EXIT CAPACITY OF DOOR OR STAIR

0

0

WALL FIRE RATING TYPEC = CORRIDORFB = FIRE BARRIER

WALL HOURLY FIRE RATING

1 = 1 HOUR2 = 2 HOUR

1-HOUR CORRIDOR SEPARATION

A. 1-HOUR FIRE RESISTIVE VERTICAL (FLOOR TO ROOF DECK) FIRE PARTITION CONSTRUCTION WITH1/3 HOUR (20 MINUTE) LABELED AUTOMATIC-CLOSING OR SELF-CLOSING SMOKE AND DRAFT CONTROLDOOR ASSEMBLY. AUTOMATIC-CLOSING DOORS SHALL HAVE SMOKE DETECTOR ACTIVATED (S-D-A)MAGNETIC HOLD OPEN DEVICES. FIRE/SMOKE DAMPERS ARE REQUIRED AT ALL DUCT PENETRATIONSWITH OPENINGS SERVING THE "CORRIDOR AND ADJACENT USE" ROOM. OPENINGS OTHER THAN DOORSOR DUCTS SHALL HAVE FIXED GLAZING OF 3/4 HOUR (45 MINUTE) LISTED AND LABELED 1/4 INCH GLASSPANELS WITH A MAXIMUM SIZE OF 1,296 SQ. IN. AND A MAXIMUM SIDE OF 54" SET IN 3/4 HOUR LABELEDSTEEL FRAMES. SIDELIGHTS AND TRANSOM LIGHTS ADJACENT TO A CORRIDOR DOOR AND INTEGRALWITH THE OVERALL FRAME SHALL HAVE THE SAME 3/4 HOUR LISTED AND LABELED 1/4 GLASS PANELSBUT SET IN 20 MINUTE LABELED STEEL FRAMES. ALL S-D-A AUTOMATIC-CLOSING DOORS AND SMOKEDAMPERS SHALL BE ACTIVATED, BY ACTUATION OF ANY FIRE ALARM DEVICE, WHEN REQUIRED, ANDPOWER FAILURE.B. DOORS MAY HAVE UP TO 1,296 SQ. IN. LABELED 1/4 INCH GLASS PANELS WITH A MAXIMUM SIDEDIMENSION OF 54 INCHES. GASKETS ARE REQUIRED AT HEADS AND JAMBS OF ALL DOORS WHENLOCATED IN CORRIDOR WALLS.C. SEAL AROUND ALL DUCTS WITHOUT FIRE AND/OR SMOKE DAMPERS, PIPES AND CONDUITPENETRATIONS WITH UL CLASSIFIED FIRE STOP SYSTEM (SAFING INSULATION AND SEALANT). FIREAND/OR SMOKE DAMPERS AT DUCT PENETRATIONS SHALL BE MOUNTED AND SEALED IN WALL WITHFACTORY FABRICATED SLEEVES AND PERIMETER MOUNTING ANGLES. SEAL TOP OF WALL TO FLOOROR ROOF DECK WITH UL CLASSIFIED FIRESTOP SYSTEM (SAFING AND INSULATION).

TWO LAYER APPLICATION

CL

MECHANICAL/ELECTRICAL CONTRACTOR TO PROVIDE FIRESTOPPING MATERIALSAT ALL MECHANICAL/ELECTRICAL PENETRATIONS THROUGH RATED WALLS, ASPER PROJECT MANUAL

1.

FOR 10" MAX DIA. PIPE THROUGHA GWB WALL.

2.

NOTE:

FIRE BARRIER WRAP STRIP

STEEL HOSE CLAMP

FIRE-RATED GWB ASSEMBLY

METAL STUD

FIRE BARRIER CAULK

16 SWG STEEL TIE WIRE

1" THICK CYLINDRICAL GLASSFIBER INSUL. 6" MIN. LENGTHUL SYSTEM NO. WL2005

MIN. 30 GAUGE METAL SLEEVE

PLASTIC PIPE OR CONDUIT

OPTION - A

3" T

YP

.

ONE LAYER APPLICATION

CL

1"

2 1/

2"1"

TWO LAYER APPLICATION

OPTION - B

ONE LAYER APPLICATION

1"

1" S

LIP

JO

INT

MIN

. CO

AT

ING

OV

ER

LAP

PE

R M

AN

UF

. RE

Q'M

TS

MIN. COATING OVERLAPPER MANUF. REQ'MTS

FIRE-RATED, ACOUSTICAL RATED, AND WALLS IN ROOMS WITH EXPOSED STRUCTURE

16 GA. RECEIVER CHANNELCONT. W/ 2 1/2" MIN. LEGSNO CONNECTION BETWEENCHANNEL AND STUDS BELOW

SCREW BETWEEN STUDS

BOTTOM OF METAL ROOFDECK OR PRE-CAST FLOOR/

CEILING SLAB

SLIP PLANE

STABILIZE STUDS AT TOPW/ CONT. CHANNEL AND

BRIDGE CLIP AT EACH STUD

METAL STUD WALL FRAMING@ 16" O.C., TYP. SEE WALLTYPE OF SIZE AND GAUGE

OF STUDS

INSULATION, SOUNDATTENTUATION BLANKETS @SOUND WALLS

GWB COVER PIECE(S),SCRIBE TO CONFORM TOTHE SHAPE OF THE METALDECK W/ SLIP REQUIREMENTS

GWB, SEE WALL TYPE FORTHICKNESS AND NUMBEROF LAYERS

SOUND ATTENUATIONBLANKETS, WHERE OCCURS

METAL STUD WALL FRAMING@ 16" O.C., TYP. SEE WALLTYPE OF SIZE AND GAUGE

OF STUDS

STABILIZE STUDS AT TOPW/ CONT. CHANNEL AND

BRIDGE CLIP AT EACH STUD

DECK OR PRE-CAST FLOOR/CEILING SLAB

SOUND ATTENUATIONBLANKETS, WHERE OCCURS

GWB, SEE WALL TYPE FORTHICKNESS AND NUMBEROF LAYERS

MINERAL WOOL CUT TOSHAPE OF DECK FLUTESAND SLIP JOINT

3/16" x 1 5/8" SCREWS @36" MAX

FIRE-RESISTIVE SPRAY COATINGAS SPECIFIED

SEALANT

STUD WALL SLIP CONNECTION DETAILS

PENETRATION FIRESTOP

SCALE: NO SCALE

BUILDING DATA:

NAME OF PROJECT: SOUTHEASTERN COMMUNITY COLLEGE - BLDG 100 INT. RENOVATIONSADDRESS: 1500 WEST AGENCY ROADPROPOSED USE: COMMUNITY COLLEGECODE ENFORCEMENT JURISDICTION: CITY OF WEST BURLINGTON

OCCUPANCY GROUP: BUSINESSMIXED USE: UNSEPARATEDAUTOMATIC SUPPRESSION: NONECONSTRUCTION TYPE: TYPE HT

FIRE RESISTANCE FOR BUILDING ELEMENTS: HOURSSTRUCTURAL FRAME 0BEARING WALLS - EXTERIOR 0BEARING WALLS - INTERIOR 0NON-BEARING WALLS - EXTERIOR 0NON-BEARING WALLS - INTERIOR 0FLOOR CONSTRUCTION 0ROOF CONSTRUCTION 0

BUILDING HEIGHT: 1-STORY

LIFE SAFETY SYSTEMS EMERGENCY LIGHTING AND EXIT SIGNAGEFIRE ALARM SYSTEM, NFPA 72AUTOMATIC SPRINKLER SYSTEM, NFPA 13

EXITING REQUIREMENTS DEAD END CORRIDOR - MAXIMUM CONDITION 50 FEETCOMMON PATH OF TRAVEL MAX. DISTANCE 100 FEETMAXIMUM TRAVEL DISTANCE 250 FEET

EGRESS WIDTH FACTOR PER OCCUPANT: .15 INCHES PER PERSON

APPLICABLE CODES:

THE BUILDING SYSTEMS WILL BE DESIGNED IN ACCORDANCE WITH THE CURRENT APPLICABLE CODES AS FOLLOWS:

THE CITY OF WEST BURLINGTON, IOWA HAS ADOPTED THE FOLLOWING CODES:

2009 INTERNATION BUILDING CODE (IBC)2009 INTERNATION EXISTING BUILDING CODE (IEBC)2009 INTERNATIONAL PLUMBING CODE (IPC)2009 NATIONAL ELECTRIC CODE (NEC)2009 INTERNATIONAL MECHANICAL CODE (IMC)2009 INTERNATIONAL FIRE CODE (IFC)

STATE CODES:

IOWA STATE BUILDING CODE, IAC 661 - CHAPTER 301 (2009)(APPLICABLE ONLY FOR STATE OWNED CONSTRUCTION PROJECTS, PROJECTS FUNDED WITH STATE FUNDS, AND WHERE LOCAL JURISDICTIONS HAVE FORMALLY ADOPTED)

STATE OF IOWA ACCESSIBILITY RULES AND REGULATIONS, IAC - CHAPTER 301 (2009)STATE OF IOWA FIRE SAFETY RULES IAC 661 - CHAPTER 200 (2009)STATE OF IOWA BUILDING THERMAL AND LIGHTING EFFICIENCY STANDARDS IAC 661 - CHAPTER 303AMERICANS WITH DISABILITIES ACT (ADA)

APPLICABLE UNDER TITLE II AS A PUBLIC ENTITY, WHICH SPECIFICALLY REFERS TO ANY STATE OR LOCAL GOVERNMENTSERVICES. THEREFORE, A SCHOOL IS CONSIDERED A "PUBLIC ENTITY".

AMERICANS WITH DISABILITIES ACT ACCESSIBILITY GUIDELINES FOR BUILDING AND FACILITIES - 2010 (ADA)(THESE REGULATIONS ARE ENFORCED BY THE U.S. JUSTICE DEPARTMENT)

PHASE 1

PHASE 2

PHASE 3

PHASE 1 - BUSINESS OFFICE (IF ALTERNATE NO. CC-01 IS TAKEN):CONSTRUCTION START: 16 MAY 2017SUBSTANTIAL COMPLETION: 20 JUNE 2017

PHASE 2 - ENROLLMENT OFFICE:CONSTRUCTION START: 16 MAY 2017SUBSTANTIAL COMPLETION: 20 JULY 2017

PHASE 3 - SUPPORT CENTER:CONSTRUCTION START: UPON COMPLETION OF PHASE 1 (IF ALT. NO. CC-1 IS TAKEN), OTHERWISEUPON COMPLETION OF PHASE 2.SUBSTANTIAL COMPLETION: 01 OCTOBER 2017

LEVEL 01100' - 0"

6"

CEILING ASSCHEDULED

EXISTINGCEILING

EXSTING GWB EXSTENDTO 6" ABOVE CEILING.

THIS SIDE ONLY.

ADD NEW GWBUP TO EXISTING

DECK

EXISTING ROOFDECK

EXISTING GWB EXTENDS TOUNDERSIDE OF EXISTINGSTRUCTURAL DECK

PAYROLL205

ADD 2 NEW LAYERS OF 5/8"GWB FROM FLOOR TOUNDERSIDE OF ROOF DECK.SEE WALL TYPES ON SHEETA1.1 (TYPE S5)

CP1.1

35

SEAL AROUND ALLPENETRATIONS TOMAINTAIN 2HR RATING

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

Rev

isio

ns

3/2

7/2

017 4

:09:5

1 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

CO

DE

PLA

N / P

HA

SIN

G P

LA

NCP1.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

NORTHSCALE: 1/8" = 1'-0"

CODE PLANSCALE: 1" = 1'-0"CP1.1

35 FIRE STOP DETAIL

Applicable Codes

NORTHSCALE: 1/16" = 1'-0"

PHASING PLAN

ADD-1

ADD-1

ADD-1

SCALE: 3/4" = 1'-0"CP1.1

31 SECTION AT 2HR FIRE BARRIER

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

ADD-1

Page 8: Addm CC-1_BLDG 100_FINAL.pdf

BUSINESSOFFICE

201

ACCOUNTANT

202

CONTROLLER

204

ENROLLMENTSERVICES

301

OFFICE

303

OFFICE

304

OFFICE

206

OFFICE

307

STOR

308

OFFICE

309

OFFICE

310

CONFERENCE

312

OFFICE

313

OFFICE

314

OFFICE

315

OFFICE

316

OFFICE

317

OFFICE

302

11' - 10 1/2"

11' -

6"

EXISTING TO REMAIN

EXISTING TO REMAIN

WORK IN BUSINESS OFFICE ISPART OF ALTERNATE NO. CC-01

4 5 12

1

7

7

1

1

1

4

4

4 5 4 5

1

1

6

1

6

6

1

1

1 1

6

2

1

1

13

6

4 11

10

9

8

8

6

11' - 0"

6

14

15

16

39' - 7 1/2"

1718

EXISTING BEAMOVERHEAD

EXISTING BEAMOVERHEAD

EXISTING BEAMOVERHEAD

EXISTING BEAMOVERHEAD

31

CP1.1

EXISTING CASEWORKTO BE REMOVED BY

OWNER

5

19

19

1

DEMOLITION NOTES

A. DEMOLITION GENERAL NOTES APPLY TO ALL DEMOLITIONSHEETS.

B. COORDINATE DEMOLITION AND PHASING EFFORTS WITHARCHITECT AND OWNER'S REPRESENTATIVES. EVERY EFFORTOPERATIONS AND TO PROVIDE BUILDING USER'S SAFETY.EXCESSIVE NOISE OR VIBRATION SHALL BE PRE-APPROVED ANDCOORDINATED WITH OWNER'S REPRESENTATIVE.

C. COORDINATE WITH THE OWNER ANY PRE-APPROVED DISRUPTIONAND VERIFICATION OF SERVICE WITHIN THE EXISTING BUILDINGSO AS TO MINIMIZE THE DISRUPTION OF SERVICE.

D. CONSTRUCT TEMPORARY CONSTRUCTION PARTITIONS WITHINEXISTING BUILDING WHICH OFFER A ONE-HOUR ENCLOSURE TOISOLATE DEMOLITION AND CONSTRUCTION WORK FROM GENERALPUBLIC AND AS DEEMED NECESSARY BY OWNER AND CODEOFFICIAL HAVING JURISDICTION. COORDINATE LOCATIONS WITHOWNER AND MAINTAIN MEANS OF EGRESS THROUGHOUT THEWORK.

E. VERIFY EXISTING CONDITIONS, DIMENSIONS, AND ELEVATIONSAND NOTIFY ARCHITECT OF DISCREPANCIES.

F. REMOVE EXISTING WALLS, DOORS, MILLWORK, PLUMBINGFIXTURES, CEILINGS, SOFFITS, MARKERBOARDS, ETC. IN THEIRENTIRETY AND AS REQUIRED TO EXECUTE DEMOLITION ANDCONSTRUCTION WORK DESCRIBED ON THE DRAWINGS.

G. THE OWNER SHALL RESERVE THE RIGHT TO SALVAGE ANYMATERIALS.

H. PROVIDE PROTECTION FOR EXISTING BUILDING MATERIALS ANDEQUIPMENT FROM DAMAGE DUE TO DEMOLITION ORCONSTRUCTION-RELATED INCIDENT PERFORMED UNDER THISCONTRACT.

I. REPAIR OR REPLACE ITEMS DAMAGED AS A RESULT OFDEMOLITION OR CONSTRUCTION TO MATCH EXISTING FINISH AND/OR CONDITION.

J. EXISTING MATERIALS SHALL NOT BE REUSED UNLESS NOTEDOTHERWISE OR AS AUTHORIZED BY ARCHITECT.

K. VERIFY AND MAINTAIN LOCATION OF EXISTING POWER,COMMUNICATION AND DATA CABLES TO PREVENT INTERRUPTIONOF SERVICE.

L. PATCH FLOOR, WALL AND CEILING PENETRATIONS RESULTINGFROM REMOVAL OR REROUTING OF NEW OR EXISTING PIPING,DUCTWORK, CONDUIT, ETC. AS REQUIRED TO MAINTAIN FIRESEPARATIONS. MATCH FINISH OF NEW OR EXISTING ADJACENTSURFACES.

M. CAP DISCONNECTED MECHANICAL PIPING LINES WITHIN WALL ORFLOOR. PATCH AND FINISH AS REQUIRED TO MATCH NEW OREXISTING ADJACENT SURFACES.

N. SEE MECHANICAL AND ELECTRICAL DRAWINGS AND NOTES FORFURTHER SEQUENCING AND SCOPE OF WORK.

O. ALL ASBESTOS/HAZARDOUS MATERIALS ABATEMENT REQUIREDTO COMPLETE SCOPE OF WORK WILL BE COMPLETED BY THEOWNER PRIOR TO THE START OF CONSTRUCTION ACTIVITIES IN ASEQUENCED AREA. THE CONTRACTOR SHALL IMMEDIATELYNOTIFY THE OWNER/ARCHITECT-ENGINEER IF ADDITIONALABATEMENT IS REQUIRED TO COMPLETE THE SCOPE OF WORKDESCRIBED IN THE CONTRACT DOCUMENTS.

APPLIES TO ALL DEMOLITION SHEETS

REMOVE DOOR AND/OR WINDOW IN ITS ENTIRETY. PATCH ANDPREPARE ADJACENT SURFACES FOR INSTALLATION OF NEW WORK,IF NECESSARY. SALVAGE AND RETURN ALL DOORS AND DOORHARDWARE TO OWNER.

REMOVE AND SALVAGE WINDOW, FRAMING, GLAZING IN ITSENTIRETY FOR REINSTALLATION AT NEW LOCATION (SEE FLOORPLAN ON SHEET A1.1 - FLOOR PLAN). PATCH AND PREPAREADJACENT SURFACES TO MATCH EXISTING OR PREPARE FORINSTALLATION OF NEW WORK, IF NECESSARY.

NOT USED.

REMOVE CEILING, LIGHTING, CONTROLS AND ASSOCIATEDELECTRICAL AND MECHANICAL ITEMS AS REQUIRED FORINSTALLATION OF NEW WORK. COORDINATE WITH MECHANICAL ANDELECTRICAL SHEETS.

REMOVE FLOOR COVERING, ASSOCIATED MATERIAL AND WALL BASEIN THEIR ENTIRETY. PATCH AND PREPARE FLOOR TO RECEIVE NEWFINISH.

REMOVE WALL, OR PORTION OF WALL, IN ITS ENTIRETY TO THEEXTENT SHOWN. FOR NEW CLEAR OPENINGS, REMOVE WALL TOHEIGHT OF NEW OPENING OR ADJACENT DOOR/WINDOWTEMPORARILY SHORE OPENINGS/STRUCTURE AS NECESSARY.

REMOVE EXISTING CASEWORK/COUNTERTOPS (BASE AND UPPERS)AND ASSOCIATED ITEMS. COORDINATE REMOVAL OFMECHANICAL/ELECTRICAL ITEMS FOR CAPPING AND TERMINATIONS.PATCH WALL AND FLOOR TO MATCH ADJACENT SURFACES.

REMOVE MARKERBOARD/TACKBOARD/SMART BOARDS/TACKSTRIPS/TV BRACKETS/WALL MOUNTED ITEMS AND RETURN TOOWNER. PATCH WALLS TO MATCH ADJACENT SURFACES FOR NEWFINISH.

CAREFULLY REMOVE, SALVAGE AND REUSE EXISTING POWER POLESAT EXISTING SYSTEMS FURNITURE, AS REQUIRED. COORDINATEWITH ELECTRICAL.

REMOVE EXISTING EXHAUST FAN, ACCESSORIES AND CONTROLS.COORDINATE WITH MECHANICAL. PATCH AND REPAIR EIFS ONEXTERIOR SIDE TO MATCH ADJACENT SURFACE. PATCH AND REPAIRGWB ON INTERIOR TO MATCH ADJACENT SURFACES AND PREPARETO RECEIVE NEW FINISH.

REMOVE AND RE-INSTALL EXISTING CEILINGS AS NECESSARY FORTHE INSTALLATION OF NEW MECHANICAL/PLUMBING/FIREPROTECTION/ELECTRICAL ITEMS. REPLACE ANY DAMAGED CEILINGTILES TO MATCH ADJACENT TILES. CUT OPENINGS IN EXISTINGTILES AS REQUIRED FOR INSTALLATION OF NEW ITEMS.

REMOVE WALLS ONLY IF ADD ALTERNATE IS TAKEN.

EXISTING VENDING MACHINES TO BE RELOCATED BY OWNER

CAREFULLY REMOVE WALL DISPLAY AND RETURN TO OWNER.

CAREFULLY REMOVE CASEWORK AND RETURN TO OWNER.

EXISTING DESK TO BE MOVED. SEE SHEET A1.1-FLOOR PLAN FORNEW LOCATION WITHIN ENROLLMENT OFFICE. EXISTING VERTICALPOWER POLE TO BE REUSED IN NEW LOCATION. PATCH AND REPAIREXISTING CARPET AND CEILING, AS NEEDED, TO MATCH EXISTING.

REMOVE RECEPTION DESK AND ASSOCIATED POWER POLE IN ITSENTIRETY AND RETURN TO OWNER. PATCH CARPET AS REQUIRED TOMATCH EXISTING.

REMOVE UPPER CABINETS AND RETURN TO OWNER. PATCH ANDREPAIR WALL BEHIND CABINETS AS NEEDED.

CAREFULLY REMOVE AND SAVE EXISTING CEILING AND GRID, ASNEEDED. RE-INSTALL CEILING AND GRID BACK TO SAME LOCATIONUPON COMPLETION OF WORK.

DEMOLITION PLAN KEY NOTES

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Rev

isio

ns

3/2

7/2

017 4

:09:4

9 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

DE

MO

LIT

ION

FLO

OR

/CE

ILIN

G P

LA

NS

AD1.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

NORTHSCALE: 1/8" = 1'-0"

DEMOLITION PLAN

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

Page 9: Addm CC-1_BLDG 100_FINAL.pdf

52A/ A0.1

43C

/ A0.

1

52B/ A0.1

43A/ A

0.1

A0.142

44A

43B

44B/ A0.151/ A

0.1

SUPPORTCENTER

101

RECEPTION

105

BUSINESSOFFICE

201

HI-SET TESTING

104

44C/ A

0.1

EXISTING LVT

EXISTING LVT

LVT-1

A0.1

54B

53/ A0.1

54A

/ A0.

1

55

LVT D

IRECTIO

N

EXISTING LVT

LVT-1

56/ A

0.1

WIN

DOW /W

ALL G

RAPHIC T

BD

P-2

P-2

P2

P2

P2P2

P2

P2 WITH WALL GRAPHIC-TBD

CG

CGCG

CG

CG

CG

CG

CGCG

CG

CGCG

CG

CG

CGCG

CG CG CG

CGCG

WINDOW GRAPHIC-TBD

WINDOW GRAPHIC-TBD

WALL GRAPHIC-TBD

WALLGRAPHIC-TBDWALL GRAPHIC-TBD

ENROLLMENTSERVICES

301

TESTING/DISABILITY

106

ADMIN. ASST.

114

TESTING

107

V.P. OFSTUDENTSERVICES

113

ADVOCATE

112

CORR

103

CORR

102

TEST./DISABILITY

108

STOR

109

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR

110

VOC. REHAB

111

ACCOUNTANT

202

PAYROLL

205

CONTROLLER

204

PURCHASINGAGENT

203

46

A0.1

31

CP1.1

1/ A0.2

MATCH EXISTING LVT/PATTERN TOEXISTING FLOORING

MATCH EXISTING CPT/PATTERN TO EXISTING FLOORING

MATCH EXISTING LVT/PATTERNTO EXISTING FLOORING

ADD-1

ADD-1

OFFICE

317

OFFICE

316

OFFICE

315

OFFICE

314

OFFICE

313

CONFERENCE

312

VEST

311

OFFICE

310OFFICE

309

STOR

308

OFFICE

307

OFFICE

206

STOR

305OFFICE

304

OFFICE

303

OFFICE

302

CG

P2

MATCH EXISTING FIELD PAINT

ADD-1

FINISH MATERIALS LIST

CARPETCPT-1 PATCRAFT 10K MODULAR

STYLE: 10510COLOR: 00510, INTERVALSIZE: 24"X24"INSTALLATION METHOD: QUARTERTURNEDADHESIVE: PRESSURE SENSITIVE ADHESIVE.

LUXURY VINYL TILELVT-1: MOHAWK COMMERCIAL FLOORING

GLOBAL ENTRY, MORIKATO - LVT FLOORINGCOLOR: 853, AKASHI CHESTNUTUNDERLAYMENT: NONE

RUBBER BASERB-1: JOHNSONITE

4" COVED RUBBER BASECOLOR: 32, PEBBLECPT-1 LOCATION

RESILIENT MOLDING ACCESSORIES:REDUCERS, ADAPTORS, ETC IN VINYL OR RUBBER TOACCOMMODATE FLOORING MATERIALS ENCOUNTERED. USECOLORS TO MATCH WALL BASE PER ROOM.

PAINT:P-1: SHERWIN WILLIAMS

PRO MAR 200 ZERO VOCCOLOR: 7006, EXTRA WHITE

P-2: MATCH EXISTING RED PAINT

P-3: SHERWIN WILLIAMSPRO MAR 200 ZERO VOCCOLOR: 7043, WORLDY GRAY

PLASTIC LAMINATEPL-1 WILSONART

STYLE: 4877-38, GREY MESH

PL-2 NEVAMARSTYLE: VA5001T, TEXTURED, THRUCOLOR-HPL, SERENESTARDOM

QUARTZQT-1 ZODIAQ: CLOUD WHITE 3CMADD-1

ADD-1

2' -

6"

3' -

6"

TRANSACTION PL-2

COUNTERTOP, PL-2

PL-1 1/8" REVEAL,PAINT BLACK

25

A0.1

15

A0.1

ADD-1

2' -

6"

3' -

6"

MOBILE PEDISTAL

COUNTERTOP, PL-2

TRANSACTION PL-2

PL-1 WITH REMOVABLE PANEL TO ACCESS ELEC.MOBILE PEDISTAL

25

A0.1

2' -

6"

3' -

6"

HI-SET TESTING BEYOND WINDOWS

2' -

6"

2' -

6"

2' -

0"

7' -

0"

TRANSACTION TOP, PL-2

PL-1

35

A0.1 PRINTER (NIC)

FIELD VERIFY GROMMITLOCATION WITH EQUIPMENT

ADD-1

2' -

0"

7' -

0"

2' -

6"

2' -

6"

EXTERIOR WINDOW

DUST PANEL LOWER CASEWORK PL-1

COUNTERTOPW/BACKSPLASH, PL-2

MULTI-FUNCTION COPIER (NIC)

PRINTER (NIC)UPPER CASEWORK, PL-1

45

A0.1

ADD-1

FIELD VERIFY GROMMITLOCATION WITH EQUIPMENT

2' -

6"

3' -

6"

MOBILE FILE (NIC)

COUNTERTOPW/BACKSPLASH,PL-2

TRANSACTION, QT-1

LOWERCASEWORK, PL-1

45

A0.1

ADD-1

ADD-1

VERIFY GROMMITSWITH EQUIPMENT

ADD-12'

- 6

"

3' -

6"

1 HR RATED COUNTER SHUTTER.BASIS OF DESIGN: CORNELLALARMGARD ERC 11SMOKESHIELD ROLLING COUNTERFIRE SHUTTER

COUNTERTOP W/BACKSPLASH, PL-2

TRANSACTION, QT-1

PL-135

A0.1

EXISTING CASEWORKRELOCATED (NIC)

PRINTER (NIC)

FIELD VERIFY GROMMITLOCATION WITH EQUIPMENT

ADD-1

ADD-1

2'-0" DEEP CLEAR CABINETS, PL-17' - 6"

12" DEEP CLEAR CABINETS, PL-110' - 6"

MICROWAVE (NIC)

COFFEE (NIC)

TOASTER (NIC)

UNDERCOUNTER REFRIGERATOR (NIC)

2' -

2"

2' -

0"

COUNTERTOPW/BACKSPLASH, PL-2

45

A0.1

2' -

10"

7' -

0"

ADD-1

4' - 0"

51

A1.1

41

A1.1 42

A1.1

52

A1.1

SLIDING CLEAR TEMPEREDGLASS, LOCKABLE

HM FRAME - PAINTP-2

6' -

2"

1' -

0"

51

A1.1

OPPADJUSTABLEGLASS SHELVING

2' -

6"

COUNTERTOPW/BACKSPLASH, PL-2

LOCKED PAPER STORAGE

PRINTER (NIC)45

A0.1

35

A0.1

ADD-1

TRANSACTION, PL-2

PL-1

1/8"REVEALS, PAINT BLACK

25

A0.1

COUNTERTOP BEYOND

ADD-1

ADD-1

TRANSACTION, PL-2

COUNTERTOP, PL-2

PL-1

1/8" REVEAL, PAINT BLACK

15

A0.1

25

A0.1

ADD-1

COUNTERTOP, PL-2

TRANSACTION, PL-2

PL-1, WITHREMOVABLE PANELSTO ACCESS ELEC.

25

A0.1

VERIFY LOCATION OFGROMMITS WITH EQUIPMENT

ADD-1

TRANSACTION, PL-2

COUNTERTOP, PL-2

PL-1 WITHREMOVABLE PANELSTO ACCESS ELEC.

15

A0.1

25

A0.1

COUNTERTOP, PL-2

3' -

4"

56B

A0.1

3"ADD-1

UN

O IN

CA

SE

WO

RK

ELE

VA

TIO

NS

SE

E E

LEV

AT

ION

SS

EE

ELE

VA

TIO

NS

SE

E E

LEV

AT

ION

S

2' - 0"

RESILIENT BASE

COUNTERTOP AND BACKSPLASH, SEEELEVATIONS FOR FINISH MATERIALAND LOCKING PREFERENCE

MDF CABINET

ADJUSTABLE SHELF

ADJUSTABLE SHELF

SEE ELEVATIONS

2" VALANCE AT CABINETS WHERELIGHTING IS PROVIDED, FINISH TOMATCH CABINET AT FACE

ADD-1

OUTLETS PER ELECTRICAL

LAMINATE WORKSURFACE

PLASTIC LAMINATE TRANSACTIONTOP, NO EXPOSED SURFACES

LAMINATE FACE, SEE ELEVATIONS

4" RESILENT BASE, APPLIEDDIRECTLY TO 1/4" PLYWOOD

3/4" PLYWOOD WITH LAMINATE FACE

2"GROMMET PLACED 4'-0" OC, STARTING 2'-0" FROM PLAN WEST EDGE, CLEAR OFMTL BRACKET.

3 5/8" MTL STUDS @ 16" O.C.

2' - 0"

TACK BOARD

A & M HARDWARE, WHITE STANDARD18" X 18" BRACKET ON PLYWD

BLOCKING

ADD-1

LAMINATE WORKSURFACE, SEEELEVATIONS

GWB, PAINT

2' - 0"

SE

E E

LEV

AT

ION

S

BASE

A & M HARDWARE, WHITE STANDARD18" X 18" BRACKET ON PLYWD

BLOCKING

BACKSPLASH ASINDICATED ON ELEVATIONS

CORDINATE LOCATION OF GROMMETSWITH OWNERS EQUIPMENT

ADD-1

LEVEL 01100' - 0"

HM DISPLAYCASE FRAME,PAINTED PT-2

52

A1.1

52

A1.1

SIM

52

A1.1

SIM

CLEARTEMPEREDGLASS

OUTLETS PER ELECTRICAL

LAMINATE WORKSURFACE

LAMINATE FACE ON 3/4" PLYWD

4" RESILENT BASE,APPLIED DIRECTLYTO 1/4" PLYWOOD

3 5/8" MTL STUDS @ 16" O.C.

2' - 11"

A & M HARDWARE, WHITE STANDARD18" X 18" BRACKET ON PLYWD

BLOCKING

ADD-1

WALL TYPE PER PLAN

PLASTIC LAMINATE,3/4" PLYWOOD

1 1/2" x 1 1/2" STEEL TUBE24" VERTICAL LEG 18"HORIZONTAL LEG FASTEN TOMETAL STUDS @ 16" O.C.

FASTEN WITH #10SCREW @ 6" O.C.

SE

E E

LEV

AT

ION

S

WALL FINISH, PER SCHEDULE

ADD-1

WINDOW TYPE PER PLAN

PLASTIC LAMINATE

1 1/2" x 1 1/2" STEEL TUBE24" VERTICAL LEG18" HORIZONTAL LEGFASTEN TO METAL STUDS@ 16" O.C.

3"

ADD-1

ADD-1

GROMMET PLACED CENTERED OFCOUNTER, CLEAR OF STEEL TUBE.

ADD-1

ADD-1

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Rev

isio

ns

3/2

7/2

017 4

:09:4

5 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

RO

OM

FIN

ISH

PLA

N A

ND

ELE

VA

TIO

NS

A0.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

NORTHSCALE: 1/8" = 1'-0"

FINISH FLOOR PLAN

SCALE: 1/4" = 1'-0"A0.1

43A RECEPTION FRONTSCALE: 1/4" = 1'-0"A0.1

43B RECEPTION-WORKSURFACESCALE: 1/4" = 1'-0"A0.1

44A RECEPTION - TRANSACTION

SCALE: 1/4" = 1'-0"A0.1

42 RECEPTION-STORAGE

SCALE: 1/4" = 1'-0"A0.1

51 BUSINESS OFFICE STORAGE

SCALE: 1/4" = 1'-0"A0.1

44B BUSINESS OFFICE - WORK SURFACESCALE: 1/4" = 1'-0"A0.1

43C BUSINESS OFFICE-BREAK AREA

SCALE: 1/4" = 1'-0"A0.1

52A DISPLAY CASESCALE: 1/4" = 1'-0"A0.1

52B STUDENT COLLEGE ACCESS STATION

SCALE:A0.1

31 CASHIER WINDOW

SCALE:A0.1

41 ENROLLMENT ENTRY

SCALE:A0.1

21 ENROLLMENT-FROM EAST

SCALE:A0.1

11 SUPPORT CENTER ENTRY

SCALE: 1/4" = 1'-0"A0.1

53 WORKSTATION-NORTHSCALE: 1/4" = 1'-0"A0.1

54A WORKSTATION-EASTSCALE: 1/4" = 1'-0"A0.1

54B WORKSTATION-SOUTHSCALE: 1/4" = 1'-0"A0.1

55 WORKSTATION-WESTSCALE: 1/4" = 1'-0"A0.1

56 STANDING HT. COUNTER

SCALE: 1" = 1'-0"A0.1

45 TYP. BASE CABINET W/ UPPER

SCALE: 1" = 1'-0"A0.1

25 RECEPTION DESK - SECTION

SCALE: 1" = 1'-0"A0.1

35 DESK WORKSURFACE

FIRE RATED COUNTER SHUTTER

SCALE: 1/4" = 1'-0"A0.1

44C DISPLAY CASE

SCALE: 1" = 1'-0"A0.1

15 LOWER RECEPTION COUNTER

SCALE: 1" = 1'-0"A0.1

46 TYP. WALL MOUNTED COUNTER

SCALE: 1" = 1'-0"A0.1

56B TYP. WALL MOUNTED COUNTER

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

ADD-1 ADD-1

ADD-1

ADD-1

ADD-1

Page 10: Addm CC-1_BLDG 100_FINAL.pdf

ROOM FINISH SCHEDULE GENERAL NOTES

A. ALL GYPSUM WALLBOARD BULKHEADS SHALL BE PAINTED P-1 UNLESS OTHERWISE NOTED.

B. NOT ALL FLOOR AND WALL FINISHES ARE NOTED ON THEINTERIOR FINISH PLANS, SEE ELEVATIONS, DETAILS, ANDROOM FINISH SCHEDULE.

C. CEILING HEIGHTS, AS NOTED ON THE REFLECTED CEILINGPLANS, ARE MEASURED FROM THE FINISH FLOOR OF THEROOM.

D. CONTRACTOR SHALL FURNISH AND INSTALL WALL BASEAROUND CASEWORK AND MILLWORK.

E. WHERE FLOOR FINISH CHANGES FROM ONE ROOM TOANOTHER, SET JOINT OF THE MATERIALS AT THE CENTER OFTHE COMMUNICATING DOOR.

F. SEE REFLECTED CEILING PLANS FOR CEILING TYPES ANDHEIGHT.

G. CONTRACTOR SHALL FIELD VERIFY FLOORING CONDITIONSAND QUANTITIES PRIOR TO BID.

H. FLOOR PATTERN LOCATIONS ARE APPROXIMATE. MINORADJUSTMENTS MAY BE MADE FOR LAYOUT AND TO MINIMIZEWASTE AS LONG AS THE DESIGN INTECT IS MAINTAINED.

I. FOR FLOOR TILE PRODUCTS, ADJUST LAYOUT ASNECESSARY TO AVOID USING CUT WIDTHS THAT EQUAL LESSTHAN ONE-HALF OF A TILE AT ROOM PERIMETER.

J. VERIFY LOCATIONS OF GROMMETS IN COUNTERTOPS WITHOWNER'S EQUIPMENT.

K. DECORATIVE FILM OVERLAY-COORDINATE FILM WITHCOLLEGE FOR COLOR AND FONT. ADD-1

ADD-1

FINISH SPECIFICATION NOTES

FLOOR NOTES:

F1. SUPPORT CENTER TO BE CPT-1

F2. MATCH NEW FLOOING WITH EXISTING FLOORING, ASREQUIRED.

WALL NOTES:

W1. MATCH NEW PAINT WITH EXISTING PAINT, AS REQUIRED.

W2. MATCH NEW RESILIENT WALL BASE WITH EXISTING WALL BASE, AS REQUIRED, PER TYPE OF FLOORING.

CEILING NOTES:

C1. SEE REFLECTED CEILING PLANS FOR CEILING ACCENTPAINT COLORS AND LOCATIONS.

C2. MATCH NEW ACP CEILING WITH EXISTING ACP CEILING, ASREQUIRED.

C3. PROVIDE 4" BATT INSULATION ABOVE CEILING TILE

MISCELLANEOUS NOTES:

M1. PART OF ALTERNATE NO. CC-1

DECORATIVE FILM OVERLAY

(DF-1): TRANSLUCENT, DIMENSIONALLY STABLE, CAST PVCFILM, 2-MIL-(0.05-MM-) MINIMUM THICKNESS, WITH PRESSURE-SENSITIVE, CLEAR ADHESIVE BACK FOR ADHERING GLASS ANDRELEASEABLE PROTECTIVE BACKING.

1. MANUFACTURERS: SUBJECT TO COMPLIANCE WITHREQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THEFOLLOWING:

A. 3M. B. AVERY DENNISON GRAPHICS C. FDC GRAPHIC FILMS, INC. D. ORAFOL

2. COLOR: WHITE, GRAY, AND BLACK

3. APPLY DECORATIVE FILM OVERLAY MATERIAL SQUARELYALIGNED TO GLASS EDGES, UNIFORMLY SMOOTH, AND FREEFROM TEARS, AIR BUBBLES, WRINKES, AND ROUGH EDGES, INSINGLE SHEET COMPLETELY THE BACK FACE OF CLEANGLASS, ACCORDING TO MANUFACTURER'S WRITTENINSTRUCTIONS, INCLUDING SURFACE PREPARATION ANDAPPLICATION TEMPERATURE LIMITATIONS.

A. INSTALL DECOREATIVE FILM ON INTERIOR, #4 SURFACEOF BOTTOM PANE GLASS PANELS ON FRAME

2' -

10"

DUST PANEL2' - 6" 1' - 0"F

PL-2 WITH BACKSPLASH

45

A0.1

DEORATIVE FILM OVERLAY-GLAZING - TWO SIDED, 3-SHADES OF GRAY & GWB-3-COLORS

DECORATIVE FILM OVERLAY OVERGLAZING, TWO SIDED, 3 SHADES OF GRAY

DECORATIVE FILM OVERLAY OVERGLAZING, TWO SIDED, 3 SHADES OF GRAY

DECORATIVE FILM OVERLAY OVER GLAZING, THREE COLORS, DIFFERENT SIZE FONTS. DECORATIVE FILM OVERLAY OVER GLAZING, THREE COLORS, DIFFERENT SIZE FONTS.

DECORATIVE FILM OVERLAY OVER GWB,P-2 (SEE FLOOR PLAN), MASCOT TO BEBLACK AND FONT TO BE WHITE,COORDINATE WITH SCC STANDARDS.

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Rev

isio

ns

3/2

7/2

017 4

:09:4

5 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

ELE

VA

TIO

NS

& R

OO

M F

INIS

H S

CH

ED

ULE

A0.2

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

ROOM FINISH SCHEDULE

ROOM

NAME FLOOR FINISH BASE FINISH

WALL

COMMENTSNUMBER MATERIAL NORTH EAST SOUTH WEST

101 SUPPORT CENTER CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1,C1

102 CORR CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

103 CORR CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

104 HI-SET TESTING CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1, C3

105 RECEPTION CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

106 TESTING/ DISABILITY CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1, C3

107 TESTING CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1, C3

108 TEST./ DISABILITY CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1, C3

109 STOR CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

110 STUDENT SUPPORT ADVOCATE/ DISABILITY COORDINATOR CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

111 VOC. REHAB CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

112 ADVOCATE CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

113 V.P. OF STUDENT SERVICES CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

114 ADMIN. ASST. CPT-1 RB-1 GWB P-3 P-3 P-3 P-3 F1

201 BUSINESS OFFICE CPT RB GWB EXIST EXIST EXIST EXIST F2, W1, W2, C1, & C2

202 ACCOUNTANT EXIST EXIST EXIST EXIST EXIST EXIST

203 PURCHASING AGENT EXIST EXIST EXIST EXIST EXIST EXIST

204 CONTROLLER EXIST EXIST EXIST EXIST EXIST EXIST

205 PAYROLL EXIST EXIST EXIST EXIST EXIST EXIST

206 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

301 ENROLLMENT SERVICES CPT RB GWB EXIST EXIST EXIST EXIST F2, W1, W2, C1, & C2

302 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

303 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

304 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

305 STOR EXIST EXIST EXIST EXIST EXIST EXIST

307 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

308 STOR EXIST EXIST EXIST EXIST EXIST EXIST

309 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

310 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

311 VEST EXIST EXIST EXIST EXIST EXIST EXIST

312 CONFERENCE EXIST EXIST EXIST EXIST EXIST EXIST

313 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

314 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

315 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

316 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

317 OFFICE EXIST EXIST EXIST EXIST EXIST EXIST

ADD-1

SCALE: 1/4" = 1'-0"A0.2

1 ENROLLMENT STORAGE

NO SCALEA0.2

4 ENROLLMENT-EASTNO SCALEA0.2

5 ENROLLMENT-WEST

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

NO SCALEA0.2

3 SUPPORT CENTER

NO SCALEA0.2

2 BUSINESS OFFICE_CASHIER

ADD-1

Page 11: Addm CC-1_BLDG 100_FINAL.pdf

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR

110

STOR

109

VOC. REHAB

111

ADVOCATE

112

V.P. OFSTUDENTSERVICES

113

TESTING

107

HI-SET TESTING

104

SUPPORTCENTER

101

ADMIN. ASST.

114

OFFICE

303

OFFICE

304

ENROLLMENTSERVICES

301 OFFICE

206

OFFICE

307

STOR

308

OFFICE

309

OFFICE

310VEST

311

CONFERENCE

312

OFFICE

313

OFFICE

314

OFFICE

315

OFFICE

316

OFFICE

317

EXISTING TO REMAIN

EXISTING TO REMAIN

BUSINESSOFFICE

201

CONTROLLER

204

PAYROLL

205

ACCOUNTANT

202

PURCHASINGAGENT

203

TEST./DISABILITY

108

TESTING/DISABILITY

106

STOR

305

REUSE EXISTING HMWINDOW FROM FRONT

ENTRY

3' - 0" 18' - 3 3/4"

OFFICE

302

13' - 7 5/16" 7' - 7 5/16" 12' - 2 3/4"12' - 4 7/8" 3' - 6"

11' - 9 7/8"

11 3/8"

6' - 10 3/4"

3' -

6 1

1/16

"3'

- 8

3/8

"8'

- 1

1 1/

4"15

' - 7

3/8

"

16' - 9 1/8" 13' - 5 5/8"

14' -

7 3

/16"

15' -

3 9

/16"

28' -

5 5

/8"

7' -

6 7

/8"

5' -

1 1

3/16

"

10' - 9 7/8" 5' - 4 7/8" 13' - 7 5/8"

EQ

EQ

45.00°

11' -

9"

4' - 10 1/2" 5' - 2 3/8"

RECEPTION

105

CORR

102

CORR

103

104

101B

106

113

107

108

109

110 111

103

112

4 3/8"

2' - 1 5/8"

11' -

5 3

/8"

201B

201A

203

204

205

TRANSACTIONCOUNTER

3' - 0

"

7' -

11

1/4"

11' -

1 7

/8"

DISPLAY CASEWORK IN BUSINESS OFFICE IS

PART OF ALTERNATE NO. CC-01

36

A1.1

10' -

3 1

/8"

6' - 0

1/8

"8' - 2 1/4"

107A

113A

106

104

107B

101A

201

301B

301C 301D

301E

312

107C

101A

301301A

101B

16' -

5"

EQ

EQ

15' - 8"

3' -

11

3/4"

202

45.00°

S3

S2

S2

S2

S2

S2

S2 S2S2

S2

18' -

8 5

/8"

S4

S2

S2S2S3

S3

S3

S2

S2

S2

S2

S2

S2

4' - 8 3/4"

3' -

0"

6' -

3 1

1/16

"

2' - 5 7/8"

1' -

0 3

/16"

5' -

7 3

/8"

3' - 2 1/8"

1' -

3 1

/8"

21' -

0"

4' - 6" 7' - 8 5/8"

EQ

EQ

11' -

4 3

/8"

5' - 9 3/8"

3' - 2 1/8"

45.00°

FE

FE

FE

FE

4' - 1

1 1/2

"

3' - 6 1/8"

9' - 4 1/8"

2' - 2"

5' - 5 5/8"

2' - 11 1/2"

4' - 0"

6' - 1

1/4

"

6' - 1

1/4

"

6' - 11 1/2"

2' - 11 1/4"

3' - 6"3' - 2 1/8"

1' -

11

5/16

"

135.00°

135.00°

5' - 1 3/4"

1' -

5"

CG

CG

CG

CG

CGCG

CG CG

CG

CG

CG CGCG

CG

CG

CG

CG

CG

CGCG

S4

S3

S5

S3S3

31

CP1.1

CG

CG

ELEVATIONE

BOTTOM CONN SILL/JAMB DETF

CBULK HEAD DET

BA

F

E

HEADER/JAMB STUD DETHEADER DET

BA

TRACK

MET WALL STUDS

TYPE S-12PAN HEAD SCREWS@ 16" OC

HEADER:MIN REQUIREMENTS2-362S162-33FOR SPAN < 9'-02-600S162-33FOR 9'-0 < SPAN < 14'-0

6"X20 GA GUSSET PLEACH SIDE W/ 2 SCREWSPER STUD ABOVE & BELOWHEADER AND @ 2'-0 OC

HEADER

EXTEND WEB OFHEADER MEMBERSAND PROVIDE 2 SCREWSPER STUD, EACH SIDE

STIFFENER STUDS1 STUD @ OPENINGS < 6'-02 STUDS @6'-0 < OPENINGS < 13'-0

BRG STUDS6" TRACK T&B

2-600S162-33FOR SPAN < 14'-0

4-3/16"DIAX4"SCREW ANCHORS

MAS WALL

SILL MEMBER TRACK@ OPENING < 9'-0TRACK & STUD MEMBER@ 9'-0 < OPENING < 12'-0

JAMB STUDSSEE HEAD/JAMBDET FOR STUDS

6"X20 GAGUSSET PLEACH SIDESILL MEMBERAND @ 2'-0

CLIP ANGLE W/ 2SCREWS INEACH LEG

METAL WALL STUDSSEE PLANS FOR SIDE,GAGE, AND SPACING

3/16" DIA X 1 1/4"SCREW ANCHORS@ 2'-8 0CPROVIDE 2 FASTENERS@ EDGE OF OPENINGS

TRACK

TYPE S-12 PANHEADED SCREWS (TYP)

WINDOWOPNG

DOOROPNG

PROVIDE 6"X20 GA GUSSET PLEACH SIDE W/ 2 SCREWS PERMEMBER @ 2'-0 OC AT BUILT-UPSILL MEMBERS@ 9'-0 < OPENING < 12'-0

(@ CEILING BULKHEAD)

6" RECEIVE TRACKW/ 2" FLANGES

2-#12 SCREWSEACH SIDE

D

CRIPPLE STUDS ABOVE HEADERTOP TRACK

BA

CRIPPLE STUDS BELOWSILL TRACK

S1 3 5/8" MTL STUDSGWB EA SIDEMIN STC 48

3 5/8" MTL STUDSGWB EA SIDEMIN STC 48UL DESIGN U419 AT 1 HOUR RATED

3 5/8" MTL STUDSGWB ONE SIDE ONLY

3 5/8" MTL STUDS2 LAYERS GWB EA SIDEMIN STC 48UL DESIGN U419 AT 2 HOUR RATED

EXISTING WALLCONTRACTOR TO VERIFY GWB GOES TO DECK, BOTH SIDESADD 2 LAYERS GWB TO ACCESSIBLE SIDEUL DESIGN U408

S2

S3

S4

20 GA STL STUD@ 16" O.C.

BATT INSULATION

GWB

FLOOR LINE

S5

MISCELLANEOUS ROUGH CARPENTRY:

GENERAL: BLOCKING OR NAILERSDETAILS: FOR ITEMS OF DIMENSIONAL LUMBER SIZE, PROVIDE CONSTRUCTION OR NO. 2 GRADE LUMBER WITH 19 PERCENTMAXIMUM MOISTURE CONTENT AND ANY OF THE FOLLOWING SPECIES:

HEM-FIR (NORTH); NLGAMIXED SOUTHERN PINE; SPIBSPRUCE-PINE-FIR; NLGAHEM-FIR; WCLIB, OR WWPASPRUCE-PINE-FIR (SOUTH); NELMA, WCLIB, OR WWPA

FOR CONCEALED BOARDS, PROVIDE LUMBER WITH 19 PERCENT MAXIMUM MOISTURE CONTENT AND ANY OF THEFOLLOWING SPECIES AND GRADES:

MIXED SOUTHER PINE, NO. 2 GRADE; SPIBHEM-FIR OR HEM-FIR (NORTH), CONSTRUCTION OR 2 COMMON GRADE; NLGA, WCLIB, OR WWPASPRUCE-PINE-FIR (SOUTH) OR SPRUCE-PINE-FIR, CONSTRUCTION OR COMMON GRADE; NELMA, NLGA, WCLIB, OR WWPA

FASTENERS: PROVIDE ALL FASTENERS OF SIZE AND TYPE NECESSARY FOR CONSTRUCTION PER THE CONTRACTDOCUMENTS.

SEALANT:

MANUFACTURER: BASF BUILDING SYSTEMS OR TREMCOTYPE: LATEX JOINT SEALANT, ACRYLIC LATEX OR SILICONIZED ACRYLIC LATEX, ASTM C 834, TYPE OP, GRADE NF.TESTING: FOR JOINTS WITH DISSIMILAR SUBSTRATES, VERIFY ADHESION TO EACH SUBSTRATE SEPARATELY; EXTEND CUTALONG ONE SIDE, VERIFYING ADHESION TO OPPOSITE SIDE. REPEAT PROCEDURE FOR OPPOSITE SIDE.BACKING: CYLINDRICAL SEALANT BACKING, ASTM C 1330TAPE: POLYETHYLENE TAPE OR OTHER PLASTIC TAPE RECOMMENDED BY SEALANT MANUFACTURER.PRIMER: AS RECOMMENDED BY MANUFACTURER.CLEANERS: AS RECOMMENDED BY MANUFACTURER.MASKING TAPE: NON-STAINING, NON-ABSORBENT MATERIAL COMPATIBLE WITH JOINT SEALANTS AND SURFACES ADJACENTTO JOINTS.

FIRE EXTINGUISHER:

TYPE: MULTIPURPOSE DRY CHEMICAL, UL-RATED 4-A:60-B:C, 10 LB NOMINAL CAPACITY, WITH MONOAMMONIUM PHOSPHATE-BASED DRY CHEMICAL IN ENAMELD STEEL CONTAINER, WALL MOUNT TYPE.

GYPSUM WALLBOARD:

MANUFACTURER: AMERICAN GYPSUM, CERTAINTEED CORP, GEORGIA PACIFIC GYPSUM LLC, LAFARGE NORTH AMERICA, USGCORPORATION, NATIONAL GYPSUM COMPANY, TEMPLE-INLAND.GENERAL: COMPLY WITH ASTM C 1396/C 1396MTYPE: WALLS - TYPE X, 5/8", LONG EDGES: TAPERED CEILINGS - 1/2", LONG EDGES: TAPERED

1 HR RATED CEILING - 1" LINER PANEL

CORNER GUARDS AND END WALL GUARDS (CG)

SURFACE MOUNTED, RESILIENT, PLASTIC CORNER GUARDS: ASSEMBLY CONSISTING OF SNAP-ON PLASTIC COVER INSTALLEDOVER CONTINUOUS RETAINER; INCLUDING MOUNTING HARDWARE; FABRICATED WITH 90-DEGREE AND CUSTOM ANGLES TOMATCH WALL CONDITIONS.

1. BASIS OF DESIGN PRODUCT: CONSTRUCTION SPECIALTIES, INC (C/S GROUP); ACROVYN SURFACE CORNER GUARDS SSM-20 SERIES, OR A COMPARABLE PRODUCT BY ONE OF THE FOLLOWING:

A. AMERICAN FLOOR PRODUCTS CO., INC.B. ARDEN ARCHITECTURAL SPECIALTIES, INC.C. BALCO, INC.D. IPC DOOR AND WALL PROTECTION SYSTEMS; DIVISION OF INPRO CORPORATION.E. KOROGARD WALL PROTECTION SYSTEMS; DIVISION OF RFJ INTERNATIONAL CORPORATION.F. PAWLING CORPORATION.

2. COVER: EXTRUDED RIGID PLASTIC, MINIMUM 0.078 INCH (2MM) WALL THICKNESS:A. PROFILE: NOMINAL 2" (50MM) LONG LEG AND 1/4" (6MM) CORNER RADIUS.B. HEIGHT: 4'-0" (1.2M).C. COLOR AND TEXTURE: AS SELECTED BY ARCHITECT FROM MANUFACTURER'S FULL RANGE.

3. RETAINER: MINIMUM 0.060 INCH (1.5MM) THICK, 1 PIECE, EXTRUDED ALUMINUM.4. TOP AND BOTTOM CAPS: PREFABRICATED, INJECTION MOLDED PLASTIC; COLOR MATCHING COVER; FIELD ADJUSTABLE FOR CLOSE ALIGNMENT WITH SNAP-ON COVER.

GWB/METAL STUDWALL, SEE PLANFOR WALL TYPE

CORNER GUARD (CG-1) CORNER GUARD (CG-2)

CORNER GUARD

GWB/METAL STUDWALL, SEE PLANFOR WALL TYPE

END WALL GUARD

5 3/4"

5 3/

4"

1/4" FIXED CLEARTEMPERED GLASS

HM FRAME BELOW

2"

HM FRAME, PAINT PT-2

SHIM AND SEALANT,BOTH SIDES

1/4" SLIDING CLEARTEMPERED GLASS

SEE PLANS FOR WALLTYPE

2"

HM FRAME, PAINTED, PT-2

1/4" FIXED CLEARTEMPERED GLASS

WHITEMELAMINE

5 3/4"

2"

SEE PLANS FORWALL TYPE

1/4" SLIDING CLEARTEMPERED GLASS

HM FRAME,PAINTED, PT-2

SEE PLANS FORWALL TYPE

SLIDING GLASS DOOR TRACK SYSTEMBASIS OF DESIGN: KNAPE & VOGT

ROLL-EZY BALL BEARING TRACKSYSTEM

WHITE MELAMINE

LEVEL 01100' - 0"

2' -

10"

2' -

6"

CASHIER'S DESK

10" MAX

PLAMTRANSACTION

COUNTER

FIRE RATED COUNTER SHUTTER

3' -

6"

TRANSACTIONWINDOW

BASIS OF DESIGN:CR LAURENCE

1 HR RATED PLAM SILL

CEILING ASOCCURS

SEE PLAN FOR WALL TYPE

CEILING AS OCCURS

VERTICAL TRACK BEYOND

A0.1

35

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

Rev

isio

ns

3/2

7/2

017 4

:09:4

6 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

FLO

OR

PLA

NA1.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

NORTHSCALE: 1/8" = 1'-0"

FLOOR PLAN

SCALE: 1" = 1'-0"A1.1

54 METAL STUD DETAILSWALL TYPES

SCALE: 1 1/2" = 1'-0"A1.1

43 CORNER GUARD

SCALE: 1 1/2" = 1'-0"A1.1

42 DETAILSCALE: 1 1/2" = 1'-0"A1.1

41 DETAIL

SCALE: 1 1/2" = 1'-0"A1.1

52 DETAILSCALE: 1 1/2" = 1'-0"A1.1

51 DETAIL

SCALE: 3/4" = 1'-0"A1.1

36 SECTION AT TRANSACTION WINDOW

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

Page 12: Addm CC-1_BLDG 100_FINAL.pdf

EXISTING TO REMAIN

EXISTING TO REMAIN

ACCOUNTANT

202CONTROLLER

204

PAYROLL

205

ENROLLMENTSERVICES

301

OFFICE

303

OFFICE

304

OFFICE

206

OFFICE

307

STOR

308

OFFICE

309

OFFICE

310

CONFERENCE

312

OFFICE

313

OFFICE

314

OFFICE

315

OFFICE

316

OFFICE

317

APC

9' - 0"

APC

9' - 0"

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR

110

STOR

109

VOC. REHAB

111

TESTING

107

ADVOCATE

112

V.P. OFSTUDENTSERVICES

113

ADMIN. ASST.

114

SUPPORTCENTER

101

HI-SET TESTING

104

TESTING/DISABILITY

106

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

GWB

7' - 8"

TEST./DISABILITY

108

APC

9' - 0"

PURCHASINGAGENT

203

BUSINESSOFFICE

201

GWB

7' - 8"

APC

9' - 0"

APC

9' - 0"

OFFICE

302

GWB

7' - 8"

CORR

102

APC

9' - 0"

GWB

7' - 8"

APC

9' - 0"

APC

9' - 0"

APC

9' - 0"

WORK IN BUSINESS OFFICE ISPART OF ALTERNATE NO. CC-01

201C

41

A3.1

TYP

41

A3.1

TYP

42

A3.1

DASHED LINE IS LINE OFEXISTING 1 HR RATEDCORRIDOR WALL ABOVE.

44

A3.1

42

A3.1

44

A3.142

A3.1

44

A3.145

A3.1

45

A3.1

45

A3.1

135.00°

5' - 4

1/2

"

90.00°

1' - 6

"

2' - 0"

1' - 6

"

2' - 0"

1' - 6

" 1' - 6"3'

- 2"

1' - 6"

135.00°

DASHED LINE IS LINE OFEXISTING 1 HR RATEDCORRIDOR WALL ABOVE.

135.00°

44

A3.1

GWB

7' - 8"

PAINT P-1

PAINT P-1

PAINT P-1

PAINT P-2

PAINT P-1

AT SUPPORT CENTER:CONTRACTOR TO CONFIRM IF

EXISTING WALL IS HUNG FROMUNDERSIDE OF DECK, OR BEARING

ON FLOOR.

31

CP1.1

PAINT EXISTINGSTRUCTURAL BEAMS P-3

TO MATCH WALLS, TYP

EXISTING CEILING TO REMAIN IN CORRIDOR.PATCH AND REPAIR, AS NEEDED, DUE TONEW CONSTRUCTION

EXISTING CEILING TO REMAIN INENROLLMENT OFFICES. PATCH AND REPAIR,AS NEEDED, DUE TO NEW CONSTRUCTION

REFLECTED CEILING PLAN NOTES:

A. REFLECTED CEILING PLAN GENERAL NOTES APPLY TO ALLREFLECTED CEILING PLAN SHEETS.

B. ALL CEILING GRIDS/PANELS SHALL BE CENTERED IN EACHROOM UNLESS NOTED OTHERWISE.

C. CEILING HEIGHTS ARE AS NOTED ON THE REFLECTEDCEILING PLAN UNLESS NOTED OTHERWISE.

D. ALL ELECTRICAL FIXTURES, SPEAKERS, SMOKE ANDTHERMAL DETECTORS, MECHANICAL GRILLES, SPRINKLERHEADS, ETC.. SHALL BE CENTERED BETWEEN CEILINGGRIDS UNLESS NOTED OTHERWISE. SPRINKLER HEADSSHALL BE WITHIN A 3" RADIUS CENTERED BETWEENCEILING GRIDS.

E. IN ACOUSTICAL CEILING PANELS WITH SCORE IN THECENTER, CENTER DEVICES REFERENCED IN NOTED, INONE HALF OF THE TILE. DO NOT LOCATE ON THE SCORE.FOR APC WITH MULTIPLE SCORED PATTERNS,COORDINATE LOCATION WITH ARCHITECT.

F. PROVIDE SUSPENSION SYSTEM AROUND ELECTRICALFIXTURES, MECHANICAL GRILLES, DIFFUSERS, ETC. ATACOUSTICAL PANEL CEILINGS.

G. ALL DIMENSIONS ON REFLECTED CEILING PLANS AREACTUAL AND ARE TO THE FOLLOWING UNLESS NOTEDOTHERWISE:

H. 1. FACE OF FINISHED WALLI. 2. FACE OF FINISHED BULKHEADSJ. 3. CENTERLINE OF COLUMNSK. 4. CENTERLINE OF TEES

EXISTING 2'x2' ACP CEILING

2'X2' ACP CEILING TILE, OR MATCH EXISTING

GWB CEILING

1 HR RATED CEILING - AER 09038

CEILING LEGEND

CEILING SPECIFICATIONS

ACOUSTICAL CEILING PANELS:MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE PRODUCTS BY ONE OF THE FOLLOWING:

1. ARMSTRONG WORLD INDUSTRIES, INC; FINE FISSURED NO.1732

2. CERTAINTEED CORP; FINE FISSURED HHF-1543. USG INTERIORS, INC; RADAR CLIMAPLUS 2220

CLASSIFICATION: PROVIDE PANELS COMPLYING WITH ASTM E 1264FOR TYPE, FORM, AND PATTERN AS FOLLOWS:

1. TYPE AND FORM: TYPE III, MINERAL BASE WITH PAINTEDFINISH;

FORM 2, WATER FELTED.2. PATTERN: CE (PERFORATED, SMALL HOLES AND LIGHTLYTEXTURED).

COLOR: WHITELR: NOT LESS THAN 0.85 FOR WHITE COLOR.NRC: NOT LESS THAN 0.55CAC: NOT LESS THAT 35.EDGE/JOINT DETAIL: ANGLED TEGULARTHICKNESS: 5/8" (16MM)MODULAR SIZE: 24" X 24" (610MM X 610MM)

METAL SUSPENSION SYSTEM:MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE PRODUCTS BY ONE OF THE FOLLOWING:

1. ARMSTRONG WORLD INDUSTRIES, INC; PRELUDE XL2. CERTAINTEED CORP; CLASSIC STAB SYSTEM3. CHICAGO METALLIC CORPORATION; SEISMIC 12004. USG INTERIORS; DONN BRAND SUSPENSION SYSTEMS, DX

WIDE-FACE, CAPPED, DOUBLE WEB, STEEL SUSPENSION SYSTEM:MAIN AND CROSS RUNNERS ROLL FORMED FROM COLD-ROLLEDSTEEL SHEET; PREPAINTED, ELECTROLYTICALLY ZINC COATED, ORHOT-DIP GALVANIZED ACCORDINT TO ASTM A 653/A 653M, NOT LESSTHAN G30 (Z90) COATING DESIGNATION; WITH PREFINISHED 15/16"(24MM) WIDE METAL CAPS ON FLANGES.

1. STRUCTURAL CLASSIFICATION: INTERMEDIATE DUTY SYSTEM.2. END CONDITION OF CROSS RUNNERS: OVERRIDE (STEPPED) OR BUTT-EDGE TYPE.3. FACE DESIGN: FLAT, FLUSH4. CAP MATERIAL: STEEL COLD-ROLLED SHEET5. CAP FINISH: WHITE

METAL EDGE MOLDINGS AND TRIM:ROLL-FORMED, SHEET METAL EDGE MOLDINGS AND TRIM: TYPE ANDPROFILE INDICATED, OR, IF NOT INDICATED, MANUFACTURER'SSTANDARD MOLDINGS FOR EDGES AND PENETRATIONS THATCOMPLY WITH SEISMIC DESIGN REQUIREMENTS; FORMED FROMSHEET METAL OF SAME MATERIAL, FINISH, AND COLOR AS THATUSED FOR EXPOSED FLANGES OF SUSPENSION SYSTEM RUNNERS.

1. PROVIDE MANUFACTURER'S STANDARD EDGE MOLDINGS THAT FIT ACOUSTICAL PANEL EDGE DETAILS AND SUSPEN- SION SYSTEMS INDICATED AND THAT MATCH WIDTH AND CONFIGURATION OF EXPOSED RUNNERS, UNLESS OTHER- WISE INDICATED.2. FOR CIRCULAR PENETRATIONS OF CEILING, PROVIDE EDGE MOLDINGS FABRICATED TO DIAMETER REQUIRED TO FIT PENETRATION EXACTLY.

ACOUSTICAL SEALANT:PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE ONE OF THE FOLLOWING:

1. ACOUSTICAL SEALANT FOR EXPOSED AND CONCEALED JOINTS:

A. PECORA CORPORATION; AC-20 FTR ACOUSTICAL AND INSULATION SEALANTB. USG CORPORATION; SHEETROCK ACOUSTICAL SEALANT.

2. ACOUSTICAL SEALANT FOR CONCEALED JOINTS:A. HENKEL CORPORATION; OSI PRO-SERIES SC-175 ACOUSTICAL SOUND SEALANT.B. PECORA CORPORATION; AIS-919.C. TREMCO, INC; TREMCO ACOUSTICAL SEALANT.

EXISTING 2'x4' ACP CEILING

FINISH CEILINGAS SCHEDULED

3 5/8" x 20GA METAL STUD BRACING @32" O.C.

3 5/8" x 20GA METAL STUDS @ 16" O.C.

5/8" GWB

SUSP APC

FINISH CEILINGAS SCHEDULED

EXTRUDED ALUM EXP JT CLOSURE

ALLOW TO SLIP

SUSP APC

FACE OF WALL

EXTRUDED ALUM EXP JT CLOSURE

ALLOW TO SLIP

CEILING AS SCHEDULED

MAINTAIN EXISTING 1 HR RATEDCORRIDOR WALL ABOVE. DEMOWALL, AS NEEDED, TOACCOMMODATE NEW RUNNERCHANNEL, BOX BEAM, ETC.

1 HR RATED HORIZONTAL MEMBRANE - AER 09038-1" GWB LINER PANEL-5/8" GWB-2 1/2" C-H STUD, 24" O.C.-J-RUNNER STUD

CEILING AS OCCURS

CEILING LEVEL7'-8" AFF

CEILING AS OCCURS

NEW GWB

NEW BOX BEAM ASREQUIRED

AT SUPPORT CENTER:CONTRACTOR TO CONFIRM IF

EXISTING WALL IS HUNG FROMUNDERSIDE OF DECK, OR BEARING

ON FLOOR.

CO

NT

RA

CT

OR

TO

VE

RIF

Y

1 HR RATED HORIZONTAL MEMBRANE - AER 09038-1" GWB LINER PANEL

-5/8" GWB-2 1/2" C-H STUD, 24" O.C.

-J-RUNNER STUD

CEILING LEVEL7'-8" AFF

1 HR RATED CORRIDOR WALL -SEE PLANS FOR WALL TYPE

CEILING AS OCCURS

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Rev

isio

ns

3/2

7/2

017 4

:09:4

8 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

RE

FLE

CT

ED

CE

ILIN

G P

LA

N, F

IRS

T L

EV

EL -

AR

EA

AA3.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

NORTHSCALE: 1/8" = 1'-0"

REFLECTED CEILING PLAN

SCALE: 1 1/2" = 1'-0"A3.1

42 DETAILSCALE: 1 1/2" = 1'-0"A3.1

43 DETAILSCALE: 1 1/2" = 1'-0"A3.1

41 DETAILSCALE: 1 1/2" = 1'-0"A3.1

44 DETAILSCALE: 1 1/2" = 1'-0"A3.1

45 DETAIL

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

ADD-1

ADD-1

ADD-1ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

Page 13: Addm CC-1_BLDG 100_FINAL.pdf

A CB

6" 2' - 0" 6"

8"2'

- 8

"8"

2' -

0"

1' -

0"

SE

E S

CH

ED

SEE SCHED SEE SCHED SEE SCHED

1

2" TYP

7' -

2"

SEE SCHEDULE

2" TYP

7' -

2"

SEE SCHED 1' - 4"

4"

2 3

2"

3' -

7"

2"2'

- 1

"

2"

1' -

0"

2"

2' - 6"

2"

2' - 6"

2"

SEE SCHED

2"

2' - 6"

2"

2' - 6"

2"

7' -

2"

4"6'

- 8

"2"

7' -

2"

2"

1' - 2"

2"

SEE SCHED

2"

1' - 2"

2"

4

CTG

FRG FRG FRG FRG

CTG CTG

FRG FRG FRG FRG

5

SIL

L H

EIG

HT

3' -

6"

T.O

. OP

EN

ING

3' -

8"

1' -

11

1/2"

CEILING LINE

FIRE RATED COUNTER SHUTTER

PROVIDE PADLOCKABLESLIDEBOLT AND HASP

COUNTER HEIGHT

T.O. WINDOW

2"

3' -

10"

2"

2"

3' - 8"

2"

4' - 0"

2"3'

- 1

0"2"

1 2

2"

EQ 2" EQ 2" EQ 2" EQ 2" EQ 2" EQ 2" EQ

2"

21' - 0"

2"

2' -

1"

2"

3' -

7"

2"

3

2"

2' - 6" 2" 2' - 6"

2"

5' - 6"

4 5

2"

2' -

1"

2"

3' -

7"

2"

2"2' - 6"

2"

2' - 10"

1' -

0"

6' -

2"

3' -

0"

4' -

2"

3' -

0"

4' -

2"

1' -

0"

6' -

2"

3' -

6"

3' -

6"

2"

2"3' - 8"

2"

4' - 0"

CTG CTG CTG CTG CTG CTGCTGFRGS

FIRE RATED WINDOW/WALL ASSEMBLY -SEE SPECIFICATION ABOVE

TRANSACTION WINDOW

FIRE RATED SILLBY OTHER

CTG

FRG FRG

FRGFRG

FRG

FRG

3' -

5"

DOOR AND WINDOW FRAME SCHEDULE GENERAL NOTES

A. ALL HOLLOW METAL FRAMES SHALL BE FILLED SOLID WITH MINERAL WOOL.B. ALL FRAMES SHALL BE INSTALLED WITH 1/4" SHIM AND SEALANT AROUND

PERIMETER OF FRAME UNLESS NOTED OTHERWISE.C. PROVIDE SMOKE GASKET AT ALL RATED DOORS AND FRAMES.D. DIMENSIONS OF ALL OPENINGS SHALL BE FIELD VERIFIED PRIOR TO FABRICATIONE. GLASS TYPES FOR DOORS ARE INDICATED IN NOTES COLUMNS OF DOOR AND

FRAME SCHEDULE OR IN SPECIFICATIONS. GLASS TYPES FOR FRAMES AREINDICATED ON FRAME ELEVATIONS OR IN SPECIFICATIONS.

F. OVERHEAD COILING COUNTER DOOR WIDTH AND HEIGHT DIMENSIONS INDICATED INDOOR AND FRAME SCHEDULE REPRESENT FURNISHED OPENING SIZE.CONTRACTOR TO COORDINATE EXACT SIZE OF DOOR WITH MANUFACTURER.

G. FRAME MANUFACTURER SHALL COORDINATE LOCATIONS OF CONCEALED CONDUITAND J-BOXES REQUIRED FOR SECURITY SYSTEM HARDWARE PRIOR TOMANUFACTURING OF HOLLOW METAL FRAMES AND COORDINATE WITH SECURITYHARDWARE AND DEVICES.

H. HM FRAMES TO BE PAINTED. COLOR TO BE DETERMINED.

4" T

YP

SOUND BATT INSULATION

SEE PLAN FOR WALL TYPE

SEALANT BOTHSIDES - TYP

WALL WHERE OCCURS

HM FRAME -FILL SOLIDWITH MINERAL WOOL

HM FRAME - FILL SOLID WITHMINERAL WOOL

SEALANT, BOTH SIDES - TYP

SEE PLAN FOR WALL TYPE

WALL BASE, BOTH SIDES

CONDUIT WHERE APPLIES - TYP

GLASS - SEE FRAME TYPES

REMOVABLE STOP ON LIBRARY SIDE

1' -

0"

STUD WALL - SEE PLANS FOR WALLTYPE

WALL WHERE OCCURS

SEALANT BOTH SIDES - TYP

HM FRAME - FILL SOLID WITH MINERAL WOOL

REMOVABLE STOP WHERE OCCURS

GLASS WHERE OCCURS - SEE FRAMETYPES

HOLLOW METAL DOORS

FIRE-RATED ASSEMBLIES: COMPLYING WITH NFPA 80 AND LISTEDAND LABELED BY A QUALIFIED TESTING AGENCY ACCEPTABLE TOAUTHORITIES HAVING JURISDICTION FOR FIRE-PROTECTION RATINGSINDICATED, BASED ON TESTING AT POSITIVE PRESSURE ACCORDINGTO NFPA 252 OR UL 10C. SMOKE- AND DRAFT-CONTROL ASSEMBLIES:PROVIDE AN ASSEMBLY WITH GASKETS LISTED AND LABELED FORSMOKE AND DRAFT CONTROL BY A QUALIFIED TESTING AGENCYACCEPTABLE TO AUTHORITIES HAVING JURISDICTION, BASED ONTESTING ACCORDING TO UL 1784 AND INSTALLED INCOMPLIANCE WITH NFPA 105. FIRE-RATED, BORROWED-LIGHTASSEMBLIES: COMPLYING WITH NFPA 80 AND LISTED AND LABELEDBY A TESTING AND INSPECTING AGENCY ACCEPTABLE TOAUTHORITIES HAVING JURISDICTION FOR FIRE-PROTECTION RATINGSINDICATED, BASED ON TESTING ACCORDING TO NFPA 257 OR UL 9.

BASIS OF DESIGN MANUFACTURER: STEELCRAFTSUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDEPRODUCTS BY ONE OF THE FOLLOWING:

1. MESKERCORE CONSTRUCTION: MANUFACTURER'S STANDARD KRAFT-PAPERHONEYCOMB, POLYSTYRENE, POLYURETHANE, POLYISOCYANURATE,MINERALBOARD,OR VERTICAL STEEL STIFFENER COREVERTICAL EDGE: BEVELED EDGETOP AND BOTTOM EDGE: CLOSED, 0.053 INCH THICKPERFORMANCE LEVEL: COLD-ROLLED STEEL SHEET, LEVEL 3 ANDPHYSICAL PERFORMANCE LEVEL A (EXTRA HEAVY DUTY), MODEL 2(SEAMLESS) WITHVERTICAL EDGES CONTINUOUSLY WELDED AND AND DRESSEDSMOOTHFACE SHEET THICKNESS: 0.053 INCH

FLUSH WOOD DOORSMANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS,PROVIDE PRODUCTS BY ONE OF THE FOLLOWING:

1. ALGOMA HARDWOODS, INC.2. EGGERS INDUSTRIES3. GRAHAM WOOD DOORS; AN ASSA ABLOY GROUP COMPANY4. MARSHFIELD DOOR SYSTEMS, INC.5. OSHKOSH DOOR COMPANY6. VT INDUSTRIES, INC.

SOURCE LIMITATIONS: OBTAIN FLUSH WOOD DOORS FROM SINGLEMANUFACTURER.

DOOR LAMINATE: FORMICA, FINNISH OAK 118-58 (MATTE FINISH)

HOLLOW METAL FRAMESBASIS OF DESIGN MANUFACTURER: STEELCRAFTFABRICATION: DIE-MITERED CORNERS, FACE WELDED UNLESSOTHERWISE INDICATEDFACE SHEET THICKNESS: 0.053 THICK STEEL SHEETGLAZING: GLASS TYPE (FRG) CLEAR TEMPERED FIRE RATEDGLAZING.

1. THICKNESS: 6.0MM2. FIRE RATING: 45, 120 MIN3. PRODUCT: SAFTIFIRST SUPERLITE I-XL45 OR COMPARABLE PRODUCT

SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE NAMEDPRODUCT OR COMPARABLE PRODUCT BY ONE OF THE FOLLOWING:

1. CURRIES2. CECO3. MESKER

SOURCE LIMITATIONS: OBTAIN ALL COMPONENTS OF HOLLOW METALSYSTEM, INCLUDING FRAMING AND ACCESSORIES, FROM SINGLEMANUFACTURER.

MANUFACTURER STANDARD WARRANTY SHALL APPLY

FIELD VERIFY ALL ROUGH OPENINGS

DOOR SCHEDULE SPECIFIC NOTES

1. CLEAR TEMPERED FIRE RATED GLASS AT SIDE LIGHT2. ONLY REQUIRED IF ALTERNATE NO. CC-1 IS TAKEN3. MAGNETIC HOLD OPEN DOORS, SEE HARDWARE SPECIFICATION. ELECTRICALCONTRACTOR TO PROVIDE POWER AND FIRE ALARM CONNECTIONS.4. OVERHEAD SHUTTER DOOR TO BE OPERABLE TO ALLOW OWNER TO CLOSE AFTERBUSINESS HOURS FOR SECURITY. INCLUDE PADLOCKABLE SLIDE BOLD AND HASP TOLOCK DOOR IN CLOSED POSITION.5. DOORS ON ELECTRONIC HOLD OPEN, SEE HARDWARE SPECIFICATION. ELECTRICALCONTRACTOR TO PROVIDE POWER AND FIRE ALARM CONNECTIONS.6. PAINT FRAME P-2; FOR DOOR A101A PAINT HM DOOR P-27. PAINT FRAME TO MATCH ADJACENT WALL SURFACE.8. PROVIDE SOUND/SMOKE GASKET AT HEAD AND JAMB

GLAZING:

PRODUCTS

1. THICKNESS: WHERE GLASS THICKNESS IS INDICATED, IT IS A MINIMUM. PROVIDE GLASS LITES IN THICKNESSES AS NEEDEDTO COMPLY WITH REQUIREMENTS INDICATED

2. STRENGTH: WHERE FLOAT GLASS IS INDICATED, PROVIDE ANNEALED FLOAT GLASS, KIND HS HEAT-TREATED FLOAT GLASS,OR KIND FT HEAT-TREATED FLOAT GLASS AS NEEDED TO COMPLY WITH PERFORMANCE REQUIREMENTS. WHERE FULLYTEMPERED GLASS IS INDICATED, PROVIDE KIND FT HEAT-TREATED FLOAT GLASS

3. THERMAL AND OPTICAL PERFORMANCE PROPERTIES: PROVIDE GLASS WITH PERFORMANCE PROPERTIES SPECIFIED, ASINDICATED IN MANUFACTURER'S PUBLISHED TEST DATE, BASED ON PROCEDURES INDICATED BELOW:

A. FOR MONOLITHIC GLASS LITES, PROPERTIES ARE BASED ON UNITS WITH LITES 6.0MM THICKB. FOR LAMINATED GLASS LITES, PROPERTIES ARE BASED ON PRODUCTS OF CONSTRUCTION INDICATED

4. FIRE RATED WINDOW AND WALL ASSEMBLY

A. BASIS OF SPECIFICATION (FRGS):

1) FIRE RATED GLAZING: PYROSTOP2) FRAMING SYSTEM: HEAT BARRIER FRAMES; HERMAN FORSTER AG.

5. MANUFACTURERS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE PRODUCTS BY ONE OF THE FOLLOWING

A. FIRE RATED GLAZING:1) PILKINGTON GROUP (DISTRIBUTED BY TECHNICAL GLASS PRODUCTS); PYROSTOP2) SAFTI (DIVISION OF O'KEEFE'S INC.); SUPER LITE II-XL-603)VETROTECH SAINT-GOBAIN NA; SGG SWISSFLAM4) GLAVERBEL, BELGIUM (DISTRIBUTED BY INTER EDGE TECHNOLOGIES); PYROBEL

B. FRAMING SYSTEM1) HERMAN FORSTER AG (SUPPLIED BY TECHNICAL GLASS PRODUCTS); PYROSTOP2) O'KEEFE'S, INC.; GLASS PROTEX (GPX)3) VETROTECH SAINT-GOBAIN NA; VDS FRAMING SYSTEM4) INTER EDGE TECHNOLOGIES; STILE LITE FRAMES

GLASS PRODUCTS

1. FLOAT GLASS: ASTM C 1036, TYPE I, QUALITY-Q3, CLASS I (CLEAR) UNLESS OTHERWISE INDICATED.

2. HEAT-TREATED FLOAT GLASS: ASTM C 1048; TYPE I, QUALITY Q3, CLASS I (CLEAR) UNLESS OTHERWISE INDICATED; OF KIND AND CONDITIONINDICATED.

A. FABRICATION PROCESS: BY HORIZONTAL (ROLLER HEARTH) PROCESS WITH ROLL-WAVE DISTORTION PARALLEL TO BOTTOM EDGE OF GLASS AS INSTALLED UNLESS OTHERWISE INDICATED.B. FOR UNCOATED GLASS, COMPLY WITH REQUIREMENTS FOR CONDITION A.C. FOR COATED VISION GLASS, COMPLY WITH REQUIREMENTS FOR CONDITION C (OTHER COATED GLASS).

FIRE-PROTECTION-RATED GLAZING

1. FIRE-PROTECTION-RATED GLAZING, GENERAL: LISTED AND LABELED BY A TESTING AGENCY ACCEPTABLE TO AUTHORITIESHAVING JURISDICTION, FOR FIRE-PROTECTION RATINGS INDICATED, BASED ON TESTING ACCORDING TO NFPA 252 FOR DOORASSEMBLIES.

2. LAMINATED CERAMIC GLAZING (FRG): LAMINATED GLASS MADE FROM 2 PLIES OF CLEAR, CERAMIC FLOAT GLASS; 5/16"(8 MM) TOTAL NOMINAL THICKNESS; COMPLYING WITH TESTING REQUIREMENTS IN 16 CFR 1201 FOR CATEGORY IIMATERIALS.

A. PRODUCTS: SUBJECT TO COMPLIANCE WITH REQUIREMENTS, PROVIDE ONE OF THE FOLLOWING:1) NIPPON ELECTRIC GLASS CO., LTD (DISTRIBUTED BY TECHNICAL GLASS PRODUCTS); FIRELITE PLUS2) SCHOTT NORTH AMERICA, INC.; LAMINATED PYRAN CRYSTAL3) VETROTECH SAINT-GOBAIN; SGG KERALITE FR-L4) SAFTI FIRST; SUPERLITE

3. FIRE RATED GLAZING FOR FIRE-RATED GLASS AND FRAMING SYSTEM (FRGS): COMPOSED OF MULTIPLE SHEETS OF HIGH VISIBLELIGHT TRANSMISSION GLASS LAMINATED WITH FIRE RESISTIVE INTERLAYERSL

A. PROPERTIES: AS STANDARD WITH MANUFACTURER SPECIFIED FOR FIRE RATED GLAZING:1) THICKNESS: 2 1/8 INCHES2) WEIGHT: 22 LBS.3) FIRE RATING: 120 MINUTES4) IMPACT SAFETY RESISTANCE: ANSI Z97.1 AND CPSC 16CFR1201 (CAT. I AND II)5) STC RATING: UP TO 46 DB

4. LOGO: EACH PIECE OF FIRE-RATED GLAZING SHALL BE LABELED WITH A PERMANENT LOGO INCLUDING NAME OF PRODUCT,MANUFACTURER, TESTING LABORATORY (UL), FIRE RATING PERIOD, SAFETY GLAZING STANDARDS, AND DATE OF MANUFACTURE

5. MATERIALS - STEEL FRAMING FOR FIRE-RATED GLASS AND FRAMING SYSTEMS:

A. STEEL FRAMING SYSTEM 120 MIN:1) STEEL FRAME: PROFILED STEEL TUBING PERMANENTLY JOINED WITH STEEL BOLTS/PINS2) INSULATION: INSULATE FRAMING SYSTEM AGAINST EFFECTS OF FIRE, SMOKE, AND HEAT TRANSFER FROM EITHER SIDE3) STEEL GLASING BEADS: EXTRUDED STEEL BEADS WITH DIMENSIONS RECOMMENDED BY MANUFACTURER TO SECURELY HOLD GLAZING MATERIAL IN PLACE4) FASTENERS: TYPE RECOMMENDED BY MANUFACTURER5) GLAZING ACCESSORIES: LINE GLAZING POCKETS WITH INTUMESCENT TAPE SUPPLIED BY FRAME MANUFACTURER. SET GLASS USING HARDWOOD, CALCIUM SILICATE, OR NEOPRENE SETTING BLOCKS.6) GLAZING COMPOUNDS: GLAZE GLASS WITH APPROVED VINYL SUPPLIED BY MANUFACTURER, CLOSED CELL PVC TAPE, OR PURE SILICONE SEALANT.

WINDOW SCHEDULE SPECIFIC NOTES

1. SEE SPECIFICATION, THIS SHEET, FORSPECIFICATION.2. ONLY REQUIRED IF ALTERNATE NO. CC-1 IS TAKEN3. WINDOW SALVAGED AND REUSED AT NEWLOCATION. PAINT FRAME TO MATCH ADJACENT WALL.4. FRAME TO BE PAINTED P-25. PAINT FRAME TO MATCH ADJACENT WALL SURFACE.

HARDWARE GROUP NO. 01 - COORDINATE WITH ELECTRICALFOR USE ON MARK/DOOR #(S):

101B

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR6 EA HW HINGE 5BB1HW NRP 652 IVE1 EA FIRE EXIT HARDWARE 9949-L-DT-F-06-249-LBL 626 VON1 EA FIRE EXIT HARDWARE 9949-L-F-06-249-LBL 626 VON1 EA RIM CYLINDER 1E72 626 BES2 EA SURFACE CLOSER 4050 EDA 689 LCN2 EA KICK PLATE 8400 10" X 1" LDW B-CS 630 IVE2 EA FIRE/LIFE WALL MAG SEM7850 689 LCN1 EA GASKETING 188S-BK S-BK ZER

OPERATIONAL DESCRIPTIONFREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS.LATCHBOLT RETRACTED BY LEVER UNLESS LOCKED BY KEY. KEY LOCKS ANDUNLOCKS LEVER.FREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS. LEVERALWAYS RIGID, ENTRANCE BY LEVER WHEN LATCHBOLT IS IN RETRACTED POSITION.SELF-CLOSING.MAGNETIC HOLD OPEN IS CONTINUOUSLY ENERGIZED ALLOWING THE DOORS TO BEHELD OPEN UNDER NORMAL BUILDING CONDITIONS. WHEN THE FIRE ALARM ISACTIVATED, POWER TO THE MAGNETIC HOLD OPEN IS DISCONNECTED CAUSING THEDOORS TO CLOSE AUTOMATICALLY.

HARDWARE GROUP NO. 02 - COORDINATE WITH ELECTRICALFOR USE ON MARK/DOOR #(S):

301

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR6 EA HW HINGE 5BB1HW NRP 652 IVE1 EA FIRE EXIT HARDWARE 9950-WDC-L-DT-F-06-LBL 626 VON1 EA FIRE EXIT HARDWARE 9950-WDC-L-F-06-LBL 626 VON1 EA RIM CYLINDER 1E72 626 BES2 EA FIRE/LIFE CLOSER 4040SE *VOLTAGE REQUIRED 689 LCN 2 EA KICK PLATE 8400 10" X 1" LDW B-CS 630 IVE1 EA GASKETING 188S-BK S-BK ZER

OPERATIONAL DESCRIPTIONFREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS. LEVERALWAYS RIGID, ENTRANCE BY LEVER WHEN LATCHBOLT IS IN RETRACTED POSITION.FREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS.LATCHBOLT RETRACTED BY LEVER UNLESS LOCKED BY KEY. KEY LOCKS ANDUNLOCKS LEVER.'SE' CLOSER IS CONTINUOUSLY ENERGIZED ALLOWING THE DOORS TO BE HELD OPENUNDER NORMAL BUILDING CONDITIONS. WHEN THE FIRE ALARM IS ACTIVATED, POWERTO THE 'SE' CLOSER IS DISCONNECTED CAUSING THE DOORS TO CLOSEAUTOMATICALLY.

HARDWARE GROUP NO. 03FOR USE ON MARK/DOOR #(S):

101A

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW NRP 652 IVE1 EA FIRE EXIT HARDWARE 99-L-F-06-SNB 626 VON1 EA RIM CYLINDER 1E72 626 BES1 EA SURFACE CLOSER 4050 SCUSH 689 LCN1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE1 EA GASKETING 188S-BK S-BK ZER

OPERATIONAL DESCRIPTIONFREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS.LATCHBOLT RETRACTED BY LEVER UNLESS LOCKED BY KEY. KEY LOCKS ANDUNLOCKS LEVER.SELF-CLOSING. TEMPLATING ALLOWS SPRING CUSH ARM TO STOP THE DOOR'S SWINGBETWEEN 85 AND 110 DEGREES.

HARDWARE GROUP NO. 03AFOR USE ON MARK/DOOR #(S):

103

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW NRP 652 IVE1 EA FIRE EXIT HARDWARE 99-EO-F-SNB 626 VON1 EA SURFACE CLOSER 4050 SCUSH 689 LCN1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE1 EA GASKETING 188S-BK S-BK ZER

OPERATIONAL DESCRIPTIONFREE EGRESS AT ALL TIMES. PRESSING PUSH BAR RETRACTS LATCHBOLTS. NOEXTERIOR TRIM.SELF-CLOSING. TEMPLATING ALLOWS SPRING CUSH ARM TO STOP THE DOOR'S SWINGBETWEEN 85 AND 110 DEGREES.

HARDWARE GROUP NO. 04FOR USE ON MARK/DOOR #(S):

109

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW 652 IVE1 EA CLASSROOM LOCK 9K37R15KS3 626 BES1 EA SURFACE CLOSER 4050 REG 689 LCN1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE1 EA WALL STOP WS406/407CCV 630 IVE

ADD GASKETING AS REQUIRED.

OPERATIONAL DESCRIPTIONOUTSIDE LEVER LOCKED AND UNLOCKED BY KEY. INSIDE LEVER ALWAYS UNLOCKED.INSIDE LEVER ALWAYS FREE FOR IMMEDIATE EGRESS.SELF-CLOSING.

HARDWARE GROUP NO. 05FOR USE ON MARK/DOOR #(S):

201A

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW 652 IVE1 EA STOREROOM LOCK 9K37R15KS3 626 BES1 EA SURFACE CLOSER 4050 REG 689 LCN1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE1 EA WALL STOP WS406/407CCV 630 IVE1 EA GASKETING 188S-BK S-BK ZER

ADD GASKETING AS REQUIRED.

OPERATIONAL DESCRIPTIONOUTSIDE LEVER LOCKED AND UNLOCKED BY KEY. INSIDE LEVER ALWAYS UNLOCKED.INSIDE LEVER ALWAYS FREE FOR IMMEDIATE EGRESS.SELF-CLOSING.

HARDWARE GROUP NO. 06FOR USE ON MARK/DOOR #(S):

107 108 110 111 112 202 203 204 205

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW 652 IVE1 EA OFFICE/ENTRY LOCK 9K37R15KS3 626 BES1 EA WALL STOP WS406/407CCV 630 IVE

OPERATIONAL DESCRIPTIONTURN/PUSH-BUTTON LOCKING; PUSHING AND TURNING BUTTON LOCKS OUTSIDE LEVER,REQUIRING USE OF KEY UNTIL BUTTON IS MANUALLY UNLOCKED. PUSH BUTTON LOCKING;PUSHING BUTTON LOCKS OUTSIDE LEVER UNTIL UNLOCKED BY KEY OR BY TURNINGINSIDE LEVER. INSIDE LEVER IS ALWAYS FREE FOR IMMEDIATE EGRESS BY KEY OR BYTURNING INSIDE LEVER. INSIDE LEVER IS ALWAYS FREE FOR IMMEDIATE EGRESS.

HARDWARE GROUP NO. 06AFOR USE ON MARK/DOOR #(S):

104 106 113

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW 652 IVE1 EA OFFICE/ENTRY LOCK 9K37R15KS3 626 BES1 EA OH STOP 90S 630 GLY

OPERATIONAL DESCRIPTIONTURN/PUSH-BUTTON LOCKING; PUSHING AND TURNING BUTTON LOCKS OUTSIDE LEVER,REQUIRING USE OF KEY UNTIL BUTTON IS MANUALLY UNLOCKED. PUSH BUTTON LOCKING;PUSHING BUTTON LOCKS OUTSIDE LEVER UNTIL UNLOCKED BY KEY OR BY TURNINGINSIDE LEVER. INSIDE LEVER IS ALWAYS FREE FOR IMMEDIATE EGRESS BY KEY OR BYTURNING INSIDE LEVER. INSIDE LEVER IS ALWAYS FREE FOR IMMEDIATE EGRESS.

HARDWARE GROUP NO. 07FOR USE ON MARK/DOOR #(S):

201B

EACH TO HAVE:QTY DESCRIPTION CATALOG NUMBER FINISH MFR3 EA HW HINGE 5BB1HW NRP 652 IVE1 EA PASSAGE SET 9K30N15KS3 NO O.S. TRIM 626 BES1 EA SURFACE CLOSER 4050 SCUSH 689 LCN1 EA KICK PLATE 8400 10" X 2" LDW B-CS 630 IVE1 EA GASKETING 188S-BK S-BK ZER

OPERATIONAL DESCRIPTIONNO OUTSIDE TRIM PREP. INSIDE LEVER IS ALWAYS FREE FOR IMMEDIATE EGRESS.SELF-CLOSING. TEMPLATING ALLOWS SPRING CUSH ARM TO STOP THE DOOR'S SWINGBETWEEN 85 AND 110 DEGREES.

OVERHEAD COILINGCOUNTER DOOR ASSEMBLYBASIS OF DESIGN: CORNELLALARMGARD SMOKESHIELDROLLING COUNTER FIRESHUTTER

PLAM COUNTERTOP BELOW

10"

2 1/2"

ALUMINUM FRAMETRANSACTION WINDOWBASIS OF DESIGN: CRLAURENCE

OVERHEAD COILING COUNTERDOOR ASSEMBLYBASIS OF DESIGN: CORNELLALARMGARD SMOKESHIELDROLLING COUNTER FIRESHUTTER

ALUMINUM FRAMETRANSACTION WINDOWBASIS OF DESIGN: CRLAURENCE

QT-2 DOUBLE EASEDEDGE, 3 CM

ADD-12 5/8"

10 1/4"

WALL - SEE PLANSFOR SIZE

CEILING AS SCHEDULED

4"

OVERHEAD COILING COUNTER DOOR ASSEMBLYBASIS OF DESIGN: CORNELL ALARMGARD ERC

11 SMOKESHIELD ROLLING COUNTER FIRESHUTTER

ALUMINUM FRAMETRANSACTION WINDOWBASIS OF DESIGN:CR LAURENCE

SHIM AND SEALANT,BOTH SIDES

Arc

hite

ctu

re E

ngin

eering

P

lan

nin

g In

teriors

©

, D

LR

Gro

up inc., a

n Io

wa c

orp

ora

tio

n, A

LL

RIG

HT

S R

ES

ER

VE

D

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Rev

isio

ns

3/2

7/2

017 4

:09:4

8 P

M

C:\R

evit\1

1-1

4110-7

0_A

R_2016_C

entr

al_

mpollm

annZ

92K

K.r

vt

11-1

4110-7

0

03-0

9-2

017

SC

C-B

UIL

DIN

G 1

00 IN

TE

RIO

R R

EN

OV

AT

ION

S

DO

OR

AN

D F

RA

ME

SC

HE

DU

LE

A9.1

20

17

SO

UT

HE

AS

TE

RN

CO

MM

UN

ITY

CO

LLE

GE

- W

ES

T B

UR

LIN

GT

ON

DOOR AND FRAME SCHEDULE

NUMBER

DOOR PANEL FRAME

FIRE RATING HARDWARE SET

DETAILS

COMMENTSNO. OF PANELS WIDTH HEIGHT THICKNESS MATERIAL GLAZING TYPE DEPTH MATERIAL TYPE HEAD JAMB LEFT JAMB RIGHT SILL

101A 1 3' - 0" 7' - 0" 1 3/4" HM B 5 7/8" HM 3 20 MIN 03 51/A9.1 51/A9.1 51/A9.1 - 6

101B 2 2' - 6" 7' - 0" 1 3/4" HM A 5 3/4" HM 1 120 MIN 01 51/A9.1 51/A9.1 51/A9.1 - 7

103 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 1 20 MIN 03A 43/A9.1 43/A9.1 43/A9.1 7

104 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06A 51/A9.1 51/A9.1 51/A9.1 - 7,8

106 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 4 06A 51/A9.1 51/A9.1 51/A9.1 - 7,8

107 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7,8

108 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7,8

109 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 1 04 51/A9.1 51/A9.1 51/A9.1 - 7

110 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

111 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

112 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

113 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06A 51/A9.1 51/A9.1 51/A9.1 - 7

201A 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 1 20 MIN 05 51/A9.1 51/A9.1 51/A9.1 - 6

201B 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 1 120 MIN 07 51/A9.1 51/A9.1 51/A9.1 - 7

201C 4' - 0" 5' - 6" STL OHD STL - 60 MIN - 55/A9.1 44/A9.1 44/A9.1 45/A9.1 2, 4

202 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

203 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

204 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

205 1 3' - 0" 7' - 0" 1 3/4" WD A 5 3/4" HM 2 06 51/A9.1 51/A9.1 51/A9.1 - 7

301 2 3' - 0" 7' - 0" 1 3/4" WD B 5 3/4" HM 1 20 MIN 02 51/A9.1 51/A9.1 51/A9.1 - 5,6

_WINDOW SCHEDULE_

FRAME

FIRE RATING

DETAILS

COMMENTSNUMBER TYPE MATERIAL DEPTH HEAD JAMB LEFT JAMB RIGHT SILL

101A 3 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

101B 3 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

104 1 HM 5 3/4" - 53/A9.1 53/A9.1 53/A9.1 53/A9.1 5

106 1 HM 5 3/4" 120 MIN 53/A9.1 53/A9.1 53/A9.1 53/A9.1 5

107A 2 HM 5 3/4" - 53/A9.1 53/A9.1 53/A9.1 53/A9.1 5

107B 1 HM 5 3/4" 120 MIN 53/A9.1 53/A9.1 53/A9.1 53/A9.1 5

107C 1 HM 5 3/4" - 45/A9.1 45/A9.1 44/A9.1 45/A9.1 5

113A 1 HM 5 3/4" - 53/A9.1 53/A9.1 53/A9.1 53/A9.1 5

201 5 ALUM 4 7/8" - 55/A9.1 45/A9.1 44/A9.1 44/A9.1 2

301A 4 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

301B 3 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

301C 3 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

301D 3 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

301E 4 HM 5 3/4" 45 MIN 53/A9.1 53/A9.1 53/A9.1 52/A9.1 4

312 - HM 8 1/4" - 53/A9.1 53/A9.1 53/A9.1 53/A9.1 3

DOOR TYPES FRAME TYPES

WINDOW TYPES

SCALE: 1 1/2" = 1'-0"A9.1

51 HEAD/JAMBSCALE: 1 1/2" = 1'-0"A9.1

52 SILL

5 3/4"

SCALE: 1 1/2" = 1'-0"A9.1

53 HEAD/JAMB/SILL

GLAZING SPECIFICATION

DOOR HARDWARE

SCALE: 1 1/2" = 1'-0"A9.1

45 JAMBSCALE: 1 1/2" = 1'-0"A9.1

44 SILL

SCALE: 1 1/2" = 1'-0"A9.1

55 HEAD

AD

D-1

Dat

e 1

AD

DM

. NO

. 1

5 3/4"

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1

ADD-1 ADD-1

ADD-1

ADD-1

ADD-1

Page 14: Addm CC-1_BLDG 100_FINAL.pdf

DEMOLITION NOTES1. ALL WORK DONE IN THIS AREA TO BE UNDER ALTERNATE NO.

CC-1.2. REMOVE ALL EXISITNG LIGHTING IN AREAS WHERE NEW

CEILINGS ARE BEING INSTALLED. REMOVE ALL WIRING BACK TOSOURCE PANEL. EXISTING CONDUIT MAY BE REUSED IF NOTDAMAGED AND IN USABLE CONDITION. REMOVE ALLABANDONED CONDUIT. SEE ARCHITECTURAL PLANS FORLOCATIONS OF NEW CEILINGS.

3. ALL EXISTING CEILING DEVICES LOCATED IN CEILINGS BEINGREMOVED, INCLUDING BUT NOT LIMITED TO, SPEAKERS,WIRELESS ACCESS POINTS, CAMERAS, PROJECTORS, ETC.SHALL BE REINSTALLED IN NEW CEILING OR SHALL BE TURNEDOVER TO THE OWNER. COORDINATE WITH OWNER.

4. REMOVE AND RELOCATE POWER POLES FOR SYSTEMSFURNITURE TO NEW LOCATION OF FURNITURE. SEEARCHITECTURAL PLANS FOR EXACT LOCATIONS.

5. EXISTING LIGHT FIXURES TO BE RELOCATED IN THE EXISTINGCEILING. SEE LIGHTING PLAN FOR LOCATION.

6. EXISTING LIGHT TO REMAIN.7. EXISTING BASEBOARD HEATER TO BE RELOCATED.

DISCONNECT AND RECONNECT TO EXISTING CIRCUIT IN NEWLOCATION. SEE MECHANICAL PLANS.

8. ROUTE EXISTING EXPOSED CONDUIT THAT IS CURRENTLYLOCATED BELOW CEILING ALONG BEAMS TO ABOVE CEILING SOIT IS CONCEALED.

9. REMOVE ALL EXISTING SURFACE MOUNTED RACEWAY IN THISAREA.

ADD 1

1

2 2

2

2

2

2

22

EXISTING PANEL 8R TO REMAIN

EXISITNG PANEL 1R TO REMAINEXISTING PANEL 1L TO REMAIN

3 3

3

3

3 3

3

3

4

5 5 5 5 5 5

2

2 36 6

7

6 6 6

5 5 5

ADD 1

8

8

8

8

9 ADD 1

9

9 9

ADD 1 ADD 1

ADD 1

Arch

itect

ure

Eng

inee

ring

Pla

nnin

g In

terio

rs

©

, DLR

Gro

up in

c., a

n Io

wa

corp

orat

ion,

ALL

RIG

HTS

RE

SER

VED

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Revis

i ons

3/27

/201

7 1:

11:0

2 PM

C:\R

evit\

11-1

4110

-70_

MEP

_201

6_C

entra

l_th

ilton

.rvt

11-1

4110

-70

03-0

9-20

17SC

C-B

UIL

DIN

G 1

00 IN

TER

IOR

REN

OVA

TIO

NS

ELEC

TRIC

AL D

EMO

LITI

ON

PLA

N, F

IRST

LEV

EL -

AREA

AED

1.1

SOU

THEA

STER

N C

OM

MU

NIT

Y C

OLL

EGE

- WES

T BU

RLI

NG

TON

NORTHSCALE: 1/8" = 1'-0"ELECTRICAL DEMOLITION PLAN, FIRST LEVEL - AREA A

ADD

1Da

te 1

Page 15: Addm CC-1_BLDG 100_FINAL.pdf

S

SJ

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR110

STOR109

VOC. REHAB111

ADVOCATE112

V.P. OFSTUDENTSERVICES

113

TESTING107

HI-SET TESTING104

SUPPORTCENTER

101

ADMIN. ASST.114

OFFICE303

OFFICE304ENROLLMENT

SERVICES301

OFFICE206

OFFICE307

STOR308

OFFICE309

OFFICE310VEST

311

CONFERENCE312

OFFICE313

OFFICE314

OFFICE315

OFFICE316

OFFICE317

BUSINESSOFFICE

201

ACCOUNTANT202

PAYROLL205

CONTROLLER204

TESTING/DISABILITY

106

PURCHASINGAGENT

203

TEST./DISABILITY

108

STOR305

AC,22

30

AC23

AC34

3

3

5

5

77

9

9

9

9

11

11

11

11

13

13

2

46

6

8

8

8

810

10

10

13

13

15

15

15

15

7

7

17 17

19

19 19

14 14

14 14

12

12

20

3236 36

25AC

2525

1

2

UNDERCOUNTER

20

3

66"

AC

66"

27

66"

7

AC,24AC,26AC,28

AC,28

OFFICE302

L1

3 5

7

7

CORR102

RECEPTION105

CORR103

1717

6

12

12

21

21

21

25

20

2

2

EXISTING PANEL 1R

38 38

5

29

31

4

AC

AC

40

ADD 1

ADD 1

ACAC AC

6

ADD 1

5AC

ADD 1

3AC

ADD 1

AC19

ADD 1

6AC

6 AC

ADD 1

ADD 1

3333 33

POWER NOTES1. LL WORK DONE IN THIS AREA TO BE UNDER ALTERNATE NO. CC-1.2. CONNECT TO EXISTING CIRCUIT IN THIS ROOM.3. INSTALL EXISTING POWER POLE IN NEW LOCATION TO EXISTING

CIRCUIT. COORDINATE EXACT LOCATION WITH FURNITURELAYOUT.

4. PROVIDE NEW 100/3 BREAKER IN EXISTING PANEL "1R" TO FEEDNEW PANEL "L1". FEEDER SIZE SHALL BE (4) #1AWG AND (1) #6AWG GRND IN 2" CONDUIT.

5. COILING FIRE DOOR. MAKE ALL REQUIRED CONNECTIONS TO FIREALARM SYSTEM AND POWER PANEL L1.

6. RELOCATED BASEBOARD HEATER. CONNECT TO EXISTINGCIRCUIT.

7. INSTALL NEW POWER POLE. DESIGN BASIS: HUBBELL HBLPP10AI.8. PROVIDE POWER TO ELECTRIFIED DOOR HARDWARE. SEE DOOR

HARDWARE SPECIFICATION FOR EXACT REQUIREMENTS.

ADD 1

ADD 1

Arch

itect

ure

Eng

inee

ring

Pla

nnin

g In

terio

rs

©

, DLR

Gro

up in

c., a

n Io

wa

corp

orat

ion,

ALL

RIG

HTS

RE

SER

VED

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Revis

i ons

3/27

/201

7 1:

11:0

0 PM

C:\R

evit\

11-1

4110

-70_

MEP

_201

6_C

entra

l_th

ilton

.rvt

11-1

4110

-70

03-0

9-20

17SC

C-B

UIL

DIN

G 1

00 IN

TER

IOR

REN

OVA

TIO

NS

POW

ER P

LAN

, FIR

ST L

EVEL

- AR

EA A

E2.1

SOU

THEA

STER

N C

OM

MU

NIT

Y C

OLL

EGE

- WES

T BU

RLI

NG

TON

NORTHSCALE: 1/8" = 1'-0"POWER PLAN, FIRST LEVEL - AREA A

ADD

1Da

te 1

Page 16: Addm CC-1_BLDG 100_FINAL.pdf

F15

F15

F15

F30

F15

F15

D D

P P

P

P P

P

P

P

P

P

PP

P

P

P

P

P

P

P

P

P

P

P P

P

P

P

P

F15 S

S

F30

F30

F30

J

STUDENTSUPPORT

ADVOCATE/DISABILITY

COORDINATOR110

STOR109

VOC. REHAB111

ADVOCATE112

V.P. OFSTUDENTSERVICES

113

TESTING107

HI-SET TESTING104

SUPPORTCENTER

101

ADMIN. ASST.114

OFFICE303

OFFICE304

ENROLLMENTSERVICES

301

OFFICE206

OFFICE307

STOR308

OFFICE309

OFFICE310VEST

311

CONFERENCE312

OFFICE313

OFFICE314

OFFICE315

OFFICE316

OFFICE317

BUSINESSOFFICE

201

ACCOUNTANT202

PAYROLL205

CONTROLLER204

TESTING/DISABILITY

106

PURCHASINGAGENT

203

TEST./DISABILITY

108

STOR305

1

2 2

2 2

22

2

2

1 1

2

2

2

2

2

2

2

2

1

1AC

2

2

2

22

2

2

42

2

2 2 3

5

2

3

1

2 2

67

3

1

2

166"

1

0 0

0

0

2

166"

C1 4

C1 4

C1 4

C1

C1

4

4

96"

C1 4

C1 4

C1 4

C1 4

C14

C14

C14

C1 4

66"

5

OFFICE302

CORR102

RECEPTION105

CORR103

AC

AC

AC

6

6

ADD 1

1

ADD 1

ADD 1

C1 4

C14

ADD 1

ADD 1

0

0

ADD 1

ADD 1

ADD 1

SPECIAL SYSTEMS NOTES1. ALL WORK DONE IN THIS AREA TO BE UNDER ALTERNATE NO.

CC-1.2. COORDINATE ROUGH-IN AND VOLTAGE REQUIREMENTS FOR

DOOR HOLD-OPEN DEVICES FURNISHED UNDER DIVISION 8.PROVIDE BOTH POWER, FIRE ALARM CONNECTIONS, ANDOTHER PROVISIONS AS REQUIRED FOR OPERATION. CONNECTTO NEAREST 120V BRANCH CIRCUIT.

3. RELOCATED POWER/DATA POLE.4. CONNECT TO CEILING MOUNTED CAMERA PROVIDED BY

OWNER. COIL 10' OF CABLE SUPPORTED PER SPECIFICATIONS.5. LOCATION OF OWNER PROVIDED EQUIPMENT AND OWNER

PROVIDED EQUIPMENT RACK. CONTRACTOR TO PULL ALLCATEGORY CABLING BACK TO THIS ROOM AND TERMINATE.

6. SMOKE DETECTOR FOR RELEASE OF COILING FIRE DOOR.MOUNT WITHIN 5 FEET OF OPENING.

7. INSTALL NEW POWER POLE. SEE POWER PLANS.

ADD 1

Arch

itect

ure

Eng

inee

ring

Pla

nnin

g In

terio

rs

©

, DLR

Gro

up in

c., a

n Io

wa

corp

orat

ion,

ALL

RIG

HTS

RE

SER

VED

LEGEND NOTESLEGEND NOTES ARE COMMON TO ALLSOME NOTES MAY NOT APPLY TO THIS SHEET

Revis

i ons

3/27

/201

7 1:

11:0

1 PM

C:\R

evit\

11-1

4110

-70_

MEP

_201

6_C

entra

l_th

ilton

.rvt

11-1

4110

-70

03-0

9-20

17SC

C-B

UIL

DIN

G 1

00 IN

TER

IOR

REN

OVA

TIO

NS

SPEC

IAL

SYST

EMS

PLAN

, FIR

ST L

EVEL

- AR

EA A

E3.1

SOU

THEA

STER

N C

OM

MU

NIT

Y C

OLL

EGE

- WES

T BU

RLI

NG

TON

NORTHSCALE: 1/8" = 1'-0"SPECIAL SYSTEMS PLAN, FIRST LEVEL - AREA A

ADD

1Da

te 1

Page 17: Addm CC-1_BLDG 100_FINAL.pdf

LIGHTING FIXTURE SCHEDULE - INTERIOR

PROJECT NAME: SCC-BUILDING 100 INTERIOR RENOVATIONS DLR GROUP PROJECT NUMBER: 11-14110-70

LAMP ELECTRICAL FIXTURE

TYPE APPROVED MFR CATALOG NUMBER (SERIES) WATTS / DRIVER / WATTS

TYPE QTY TYPE BALLAST VOLTS / VA MOUNTING TYPE DESCRIPTION

DL1 PATHWAY 6VLB3040WG-GIW SERIES 6-INCH APERATURE, ALUMINUM SPECULAR CLEAR ALZAK PARABOLIC REFLECTOR

LIGHTOLIER (EQUIVALENT) L M 36W LED DRIVER 277 36 RECESSED 6" WITH DECORATIVE FROSTED GLASS DISC 1" X 1" EQUIVALENT TO "MIRIAM GLASS"

JESCO (EQUIVALENT) 4000K (DIM) / 40 EITHER LED (DESIGN BASIS), GALVANIZED STEEL HOUSING, TOP OR BOTTOM SERVICE,

OMEGA (EQUIVALENT) CRI: 80+ IN GWB DNLT UL LISTED FOR DAMP LOCATIONS, UNIVERSAL MOUNTING BRACKETS, 0-10V 10%

PORTFOLIO (EQUIVALENT) 3000 LM OR GRID WITH DECO DIMMING STANDARD, WIDE DISTRIBUTION (70-75 DEGREES),

GOTHAM (EQUIVALENT) (DESIGN CEILINGS GLASS DISC DELIVERED LUMENS: 2800 (MIN), EFFICACY: 80 LM/W (MIN), POWER: 42 W (MAX).

PRESCOLITE (EQUIVALENT) BASIS) (SEE PLANS SEE SECTION 265100 FOR SPECIAL WARRANTY REQUIREMENTS.

JUNO (EQUIVALENT) FOR CEILING MAX 8" HEIGHT

INTENSE (EQUIVALENT) TYPE)

RL1 WILLIAMS AHT-G-22-LED SERIES CLEAR ACRYLIC PRISMATIC DIFFUSER, STEEL HOUSING, BAKED WHITE ENAMEL

COLUMBIA (EQUIVALENT) L M 43W LED LED 277 43 RECESSED 2' x 2' FINISH PAINTED AFTER FABRICATION, ROOM-SIDE ACCESS TO REPLACEABLE LED

FINELITE (EQUIVALENT) 4000K DIM / 50 GRID HIGH- STRIPS AND DRIVER, HEAT SINK, ACCESSORIES FOR A COMPLETE INSTALLATION.

DAYBRITE (EQUIVALENT) 4000 LM PERFORMANCE DELIVERED LUMENS > 3700 LM, EFFICACY > 86 LM/W, POWER < 50 W, INTEGRAL

CREE (EQUIVALENT) (NOMINAL) LED TROFFER 10KV SURGE PROTECTION, AT 50000 HOURS > LM-70 PER IES TM-21, CRI > 80,

AXIS LIGHTING (EQUIVALENT) POWER FACTOR > 0.95, THD < 20%, 0-10V DIMMING DOWN TO 10%

LITHONIA (EQUIVALENT)

MAXLITE (EQUIVALENT)

DECO (EQUIVALENT)

RL2 WILLIAMS AHT-G-22-LED SERIES CLEAR ACRYLIC PRISMATIC DIFFUSER, STEEL HOUSING, BAKED WHITE ENAMEL

COLUMBIA (EQUIVALENT) L M 64W LED LED 277 64 RECESSED 2' x 2' FINISH PAINTED AFTER FABRICATION, ROOM-SIDE ACCESS TO REPLACEABLE LED

FINELITE (EQUIVALENT) 4000K DIM / 70 GRID HIGH- STRIPS AND DRIVER, HEAT SINK, ACCESSORIES FOR A COMPLETE INSTALLATION.

DAYBRITE (EQUIVALENT) 6000 LM PERFORMANCE DELIVERED LUMENS > 5500 LM, EFFICACY > 88 LM/W, POWER < 70 W, INTEGRAL

CREE (EQUIVALENT) (NOMINAL) LED TROFFER 10KV SURGE PROTECTION, AT 50000 HOURS > LM-70 PER IES TM-21, CRI > 80,

AXIS LIGHTING (EQUIVALENT) POWER FACTOR > 0.95, THD < 20%, 0-10V DIMMING DOWN TO 10%

LITHONIA (EQUIVALENT)

MAXLITE (EQUIVALENT)

DECO (EQUIVALENT)

RL3 MARK (ACUITY) SL4L-4FT-RLP-FL-80CRI-35k REGRESSED DIFFUSER, WHITE POWDER COAT PAINT

COLUMBIA (EQUIVALENT) L M 24W LED LED 277 24 RECESSED 4" x 4'

FINELITE (EQUIVALENT) 3500k FLANGE RECESSED

DAYBRITE (EQUIVALENT) 600 LM/FT SLOT DELIVERED LUMENS > 2400 LM, EFFICACY > 88 LM/W, POWER < 70 W, INTEGRAL

CREE (EQUIVALENT) LED AT 50000 HOURS > LM-70 PER IES TM-21, CRI > 80,

AXIS LIGHTING (EQUIVALENT) WALL WASH

LITHONIA (EQUIVALENT)

MAXLITE (EQUIVALENT)

DECO (EQUIVALENT)

SL1 MARK (ACUITY) SL2L-2FT-FLP-FL 2' 80 CRI, 50,000-HR LIFE, COLOR ROLL STEEL PAINTED WHITE AFTER FABRICATION.

APPROVED MFR (EQUIVALENT) L M LED LED 277 8 RECESSED LED FLUSH ACRYLIC LENS

4000K GYP RECESSED 85+LM/W

400LM/FT LINEAR

X1 PHILIPS ER55LD3 SERIES SINGLE FACE, UNIFORM ILLUMINATION OF RED LETTERS, CONTEMPORARY DIE-

DUAL-LITE SE SERIES L M 2W LED - DUAL 2 UNIVERSAL DIE-CAST CAST ALUMINUM HOUSING, WHITE STENCIL/FACE, WHITE HOUSING, MATTE BAKED-

LITHONIA LE SERIES 120/ / 2 EXIT SIGN ON POWDER-COAT FINISH, FIELD-CONVERTIBLE CHEVRON ARROWS, UNIVERSAL-

BEGHELLI LC SERIES 277 MOUNT, SURGE PROTECTION, NFPA 101 COMPLIANCE, UL LISTED FOR DAMP

LUMAX DCLX SERIES SINGLE LOCATIONS, UL 924, NI-CAD BATTERY, SELF-DIAGNOSTICS.

LIGHTALARMS XD SERIES FACE SEE SPECIFICATIONS FOR MORE INFORMATION.

LIGHTOLIER LD2 SERIES

MULE MD SERIES

EMERGENSEE SEEEXDC SERIES

EM DUAL-LITE EVHC61 SERIES LOW-PROFILE LED EMERGENCY EGRESS LIGHTING UNIT, 6" H x 9" W x 2.5" D,

L M 6W - 277 6 WALL EMERG WHITE HIGH-IMPACT THERMOPLASTIC HOUSING, MAINTENANCE-FREE NICKEL

EGRESS METAL HYDRIDE (NiMH) BATTERY, 90 MINUTE OPERATION, TEST SWITCH,

325 LM/HEAD LTG UNIT STATUS INDICATORS, FULLY ADJUSTABLE DUAL HEADS.

SELF-DIAGNOSTICS

PERFORMANCE REQUIRMENT: MUST PROVIDE 1 FC AVERAGE AND 0.1 FC MINIMUM

FOR 6'-0" WIDE PATH OF EGRESS, 30'-0" MINIMUM SPACING, 7'-10" MOUNTING HEIGHT.

ADD 1

ADD 1

ADD 1

PANEL SCHEDULEPANEL:L1 LOCATION: VOLTS: 208Y/120 PH: 3-Phase W:4-Wire

AMP MAIN BRKR:100 AMP MLO: SCCR: 10,000 MOUNT: SURFACEFED FROM:EXIST. PNL 1R

LOAD CKT P CIR P CIR P CKTLOAD

CIRCUIT DESCRIPTION VA BKR # H # BKRVA CIRCUIT DESCRIPTION

SMOKE DAMPERS, DOOR HOLD-OPENS, COILING FIRE DOOR 500 20 1 1 A 2 1 201000RECEPTACLES: PRINTER 105

RECEPTACLES: 110 800 20 1 3 B 4 1 201000RECEPTACLES: PRINTER 105

RECEPTACLES: 111 800 20 1 5 C 6 1 201000RECEPTACLES: 105

RECEPTACLES: 103, 109, 112 1200 20 1 7 A 8 1 20 800 RECEPTACLES: 104

RECEPTACLES: 107, 108 800 20 1 9 B 10 1 20 600 RECEPTACLES: 104

RECEPTACLES: 107, 108 800 20 1 11 C 12 1 20 800 RECEPTACLES: 101

RECEPTACLES: 107, 108 800 20 1 13 A 14 1 20 800 RECEPTACLES: 106

RECEPTACLES: 107, 108 800 20 1 15 B 16 1 20 SPARE

RECEPTACLES: 113 1000 20 1 17 C 18 1 20 SPARE

RECEPTACLES: 114 800 20 1 19 A 20 1 20 SPARE

RECEPTACLES: CORRIDOR, 301 600 20 1 21 B 22 1 201200RECEPTACLE: MICROWAVE 301 - NOTE 1

RECEPTACLES: PRINTER 301 800 20 1 23 C 24 1 20 800 RECEPTACLE: TOASTER 301 - NOTE 1

RECEPTACLES: CORRIDOR, 301 800 20 1 25 A 26 1 201000RECEPTACLE: COFFEE MAKER 301 - NOTE 1

RECEPTACLE: 1000 20 1 27 B 28 1 20 400 RECEPTACLES: 301 - NOTE 1

RECEPTACLE: 1000 20 1 29 C 30 1 20 800 RECEPTACLE: REFRIGERATOR 301 - NOTE 1

RECEPTACLE: PRINTER 301 1000 20 1 31 A 32 1 201000RECEPTACLE: PRINTER 301 - NOTE 1

RECEPTACLES: 301 600 20 1 33 B 34 1 201000RECEPTACLE: PRINTER 301 - NOTE 1

SPARE 20 1 35 C 36 1 20 400 RECEPTACLES: 301 - NOTE 1

SPARE 20 1 37 A 38 1 20 400 RECEPTACLES: - NOTE 1

SPARE 20 1 39 B 40 1 20 864 COILING FIRE DOOR - NOTE 1

SPARE 20 1 41 C 42 1 20 SPARE

LOAD SUMMARY: CONNECTED FEEDER / SERVICE CALCULATION

LIGHTING 0.00KVA 0.00 KVA (125%)

LARGEST MOTOR 0.00KVA 0.00 KVA (125%)

MOTORS 0.00KVA 0.00 KVA (100%)

RECEPT 15.80KVA 12.90 KVA (10KVA @ 100%, REMAIN @ 50%)

KITCHEN EQUIPMENT 3.80KVA 2.47 KVA (65%)

ELECTRONIC LOADS 2.00KVA 2.00 KVA (100%)

ELECTRIC HEATING 0.00KVA 0.00 KVA (100%)

MISC. 6.36KVA 6.36 KVA (100%)

TOTALS 28KVA 24 KVA HI-PHASE

78AMPS 66 AMPS 73A

NOTES:

1. UNDER ALTERNATE CC-1. BASE BID 20-AMP SINGLE POLE SPARE.

2. FURNISH WITH INTEGRAL SURGE PROTECTION DEVICE (TVSS) PER THE SPECIFICATIONS.

3.

4.

5.

6.

ADD 1

TOGGLE SWITCHRECEPTACLETECHNOLOGY OUTLETFIRE HORN/STROBEPANELBOARD

42"18"18"94"72" TO TOP

DEVICE HEIGHT AFF TO CENTERLINEOF BOX, UNLESSOTHERWISE NOTED

DEVICE MOUNTING HEIGHT SCHEDULE

Arch

itect

ure

Eng

inee

ring

Pla

nnin

g In

terio

rs

©

, DLR

Gro

up in

c., a

n Io

wa

corp

orat

ion,

ALL

RIG

HTS

RE

SER

VED

Revis

i ons

3/27

/201

7 1:

11:0

1 PM

C:\R

evit\

11-1

4110

-70_

MEP

_201

6_C

entra

l_th

ilton

.rvt

11-1

4110

-70

03-0

9-20

17SC

C-B

UIL

DIN

G 1

00 IN

TER

IOR

REN

OVA

TIO

NS

ELEC

TRIC

AL S

CH

EDU

LES

AND

DET

AILS

E4.1

SOU

THEA

STER

N C

OM

MU

NIT

Y C

OLL

EGE

- WES

T BU

RLI

NG

TON

ADD

1Da

te 1