suite 500 2815 coliseum centre drive charlotte, north carolina 28217 t] 704.379.1919 f] 704.379.1920 www. adw architects.com Addendum #1 July 26, 2018 Re: Addendum No. 1 Pilot Mountain State Park Visitor Center 1792 Pilot Knob Park Road Pinnacle, NC 27043 ADW Job No. 16088 These clarifications constitute Addendum No. 1 and considered part of the Bid Documents. General Contractor shall see that their sub-contractors are in full receipt of the information contained herein. General Clarifications: 1.) Mailed bids will not be accepted. Bids are to be hand delivered to the Pilot Mountain State Park Visitors Center attention Matt Windsor at 1792 Pilot Knob Park Road, Pinnacle, NC 27043. 2.) The GC is to maintain the existing park entry road clean of mud, dirt & debris due to construction activities by washing or sweeping as needed or as directed by the Park Superintendent. 3.) The GC is to coordinate with the Park Superintendent any deliveries or construction activities that occur Friday before a Holiday weekend 4.) See attached pre-bid meeting attendance list for July 25 th , 2018. Project Manual: 1.) Section 00 01 01 Table of Contents. a. See attached revised Table of Contents which includes a listing of items in divisions 00, 01 & 03. 2.) Section 01 23 00 Alternates: a. Part 2-Products: Item 2.02-Alternate No. 2: Add storage room #108 to receive Epoxy Floor. 3.) Section 06 18 00 prefabricated Structural Wood: Section 1.02 part C-manufacturers: Add Timber Systems, 162 S. Saginaw Street, Lapeer, MI (810) 245-6212 Contact Kristin Riedel as an approved manufacturer. 4.) Section 07 27 26 Fluid-Applied Membrane Air Barriers: Part 2.3 A item 1: Add TK-Airmax 2104 Vapor Permeable Air Barrier and TK-Climate Tech by TK products Construction Coatings as an acceptable manufacturer and products. 5.) Section 12 21 14 Horizontal wood blinds: The following rooms are to receive horizontal wood blinds: Multi-purpose #105 (3-windows Type E)
13
Embed
Addendum #1 - North Carolina Pilot Mountain New... · Addendum #1 . July 26, 2018 . Re: Addendum No. 1. Pilot Mountain State Park Visitor Center . 1792 Pilot Knob Park Road . Pinnacle,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
suite 500 2815 coliseum centre drive charlotte, north carolina 28217 t] 704.379.1919 f] 704.379.1920 w w w . a d w a r c h i t e c t s . c o m
Addendum #1 July 26, 2018 Re: Addendum No. 1 Pilot Mountain State Park Visitor Center 1792 Pilot Knob Park Road
Pinnacle, NC 27043 ADW Job No. 16088
These clarifications constitute Addendum No. 1 and considered part of the Bid Documents. General Contractor shall see that their sub-contractors are in full receipt of the information contained herein.
General Clarifications:
1.) Mailed bids will not be accepted. Bids are to be hand delivered to the Pilot Mountain State Park Visitors Center attention Matt Windsor at 1792 Pilot Knob Park Road, Pinnacle, NC 27043.
2.) The GC is to maintain the existing park entry road clean of mud, dirt & debris due to construction activities by washing or sweeping as needed or as directed by the Park Superintendent.
3.) The GC is to coordinate with the Park Superintendent any deliveries or construction activities that occur Friday before a Holiday weekend
4.) See attached pre-bid meeting attendance list for July 25th, 2018. Project Manual:
1.) Section 00 01 01 Table of Contents. a. See attached revised Table of Contents which includes a listing of items in divisions 00,
01 & 03.
2.) Section 01 23 00 Alternates: a. Part 2-Products: Item 2.02-Alternate No. 2: Add storage room #108 to receive Epoxy
Floor.
3.) Section 06 18 00 prefabricated Structural Wood: Section 1.02 part C-manufacturers: Add Timber Systems, 162 S. Saginaw Street, Lapeer, MI (810) 245-6212 Contact Kristin Riedel as an approved manufacturer.
4.) Section 07 27 26 Fluid-Applied Membrane Air Barriers: Part 2.3 A item 1: Add TK-Airmax 2104 Vapor Permeable Air Barrier and TK-Climate Tech by TK products Construction Coatings as an acceptable manufacturer and products.
5.) Section 12 21 14 Horizontal wood blinds: The following rooms are to receive horizontal wood
blinds: Multi-purpose #105 (3-windows Type E)
Page 2 of 2 a d w a r c h i t e c t s
Multi-purpose #106 (3-windows Type E) Open office #111 (2-windows Type D) Superintendent #112 (1-window Type D) Retail #103 (3-windows Type E)
Drawings:
1.) Cover sheet A000: a. Delete C504 from the drawing list. This sheet does not exist in the civil drawings. b. Alternates: Alternate #2-add storage room #108 to receive epoxy floor system.
2.) C100:
a. Sheet Index: Delete sheet C504 from index.
3.) C200: a. Delete reference to alternate #2 at patio area. Patio area will be in the base bid.
4.) S100:
a. See attached sheet S100 for footing revision along grid C1.
5.) S200: a. See attached sheet S200 for top of wall revisions along grid 7.
6.) S503:
a. See attached sheet S503 for revisions to detail 3/S503.
Exhibit Drawings:
1.) See attached revised sheet CW-3 of the exhibit drawings. The beam that bisects the displays has been changed to a plywood beam wrapped in veneer to match Glulam beams.
End of Addendum #1 Cc: \File
SECTION 00 01 10 – TABLE OF CONTENTS
SCO ID# 16-14418-01A 00 01 10 - 1
PILOT MOUNTAIN VISITOR CENTER Pinnacle, NC ADW Project Number: 16088.00
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS Section 00 01 01 - Project Title Page Section 00 01 10 - Table of Contents Section 00 01 11 - Professional Seals Page Section 00 01 15 - List of Drawings Section 00 11 13 - Advertisement for Bids Section 00 21 19 - Notice to Bidders Section 00 31 32 - Geotechnical Data Section 00 31 33 - Pilot Mountain Visitor Center Geotech Report Section 00 72 00 - Instruction to Bidders & General Conditions Section 00 73 00 - Supplementary General Conditions Section 00 74 00 - Guidelines for MBE Participation in State Construction Projects
- Form of Proposal - MBE Contractor List and Affidavits A thru E - Form of Bid Bond - Form of Construction Contract Checklist - Form of Construction Contract - Form of Performance Bond - Form of Payment Bond - Sheet for attaching Power of Attorney - Sheet for attaching Insurance Certificates - Form of Approval of the Attorney General and the Office of State
Budget and Management
END OF SECTION 00 01 10
CDRevisions
Notes
PIL
OT
MO
UN
TAIN
STA
TE P
AR
KP
INN
AC
LE, N
C
334.500
4.000
12.000 12.000 12.000
60.000 67.000 77.000
4.000
4.000
78.000
34.500 60.000 48.000 48.000 36.000 36.000 36.000
SECTION 3&5CENTERWALL-1
CW-3
6/20/2018 DMH6/28/2018 DMH
PLYWOOD BEAM WRAPPED IN VENEER (specified to match GLULUM BEAMS)
ARTIFACT CASES WITH ADJUSTABLE SHELVING BLACK, OR TEMPERED GLASS SHELVES•1/4" THICK TEMPERED GLASS GLAZING ON OUTSIDE OF CASE•ACCESS BY TAKING OFF TOP AND BOTTOM LAMINATED PANELS•