Top Banner
Adam Para, October 14, 2005 First look at PFA/clustering with RPC- based calorimeter Progress Report
15

Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Dec 15, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Adam Para, October 14, 2005

First look at PFA/clustering with RPC-

based calorimeter

Progress Report

Page 2: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Step 1: Gas calorimetry

GEANT 3.21 modeling Hadron shower simulation

(GCALOR+GFLUKA) consistent with MINOS test calorimeter

2 cm iron, 1x1 cm2 readout pads

Pad multiplicity = 1 + with p =

2,5,10,20,50,100 GeV/c, 1000events at each momentum• Significant non—linearity of

the response (~20% @ 100 GeV)

• Large constant term (~10%) for the energy resolution

• Why ?

Page 3: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Gas calorimetry ctnd• 20 GeV:

• E/E 0.132, or

• E/E=0.59/√E

• Fairly gaussian response

• 2 GeV (‘low energy’):

• long tail towards higher response

•It is caused by particles traversing long distance before the interaction

•Expect very large difference in the response to charged and neutral particles

• 100 GeV (‘high energy’):

• long tail towards low energies

• caused by multiply hit cells inside EM showers

• saturation leads to degradation of energy (constant term, non-linearity)

Page 4: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

PFA: what do we want?

PFA Challenge:

• identify and discard all red/green points

•Identify and count all blue points

Chief (?) difficulties:

• identify ‘blue’ cluster in the midst of the red/green one

•Properly identify the disconnected red cluster (a.k.a. ‘fragment’)

Page 5: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

PFA: is it obviously impossible?

Yes? Hadrons impact the calorimeter at ~ 10 cm distance Hadronic shower has transverse dimension of ~40-50 cm Hadronic showers are extremely irregular, they do not

follow ‘shower profile’

No? Hadronic showers are extremely irregular, they do not

follow ‘shower profile’ Shower develops in 3 dimensions. ALL displays are

projections on 2D plane and they convey unnecessarily pessimistic picture

Although to contain the shower energy one needs a ‘cylinder’ ~40-50 cm, L=100 cm for any particular hadron shower this cylinder is very sparsely occupied. Example: such a cylinder contains ~8,000 readout cells, 1 x 1 cm2. Only ~ 1000 of them are hit. Occupancy is ~12%

Page 6: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

PFA Challenge: develop a metric in the hit cells space

which optimizes the separation of ‘charged hadron cluster’ from ‘neutral hadron clusters’

Figure of merit: minimize fluctuations of the energy in the clusters classified as ’neutral hadrons’ about the true energy of the neutral hadrons

Auxiliary information: momentum and spatial position of charged hadrons, possibly energy deposition in the hit cell

Page 7: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

First try: cartesian distance

Find trees of hits with close proximity, d<dcut

Here the example of 20 GeV charged pion, dcut=5 cm

‘Objetcs’ found: Clusters Single points

Page 8: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Cartesian distance, typical example

20 GeV + dcut = 20 cm

Page 9: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Total energy of the ‘main cluster’

High energy showers are more collimated, hit cells are closer

Page 10: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

“Fragments” multiplicity and energy

Energy of the ‘second’ cluster

(~10 hits = 1 GeV)

Total number of clusters found

Page 11: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

Leftovers: single hits

‘free floating’ single hits are probably harmless, there are so few of them that they will not lead to accidental cluster formation

Ignoring scattered single one modifies the effective energy calibration (1-2% effect) but induced non-linearity of the response is minimal.

Page 12: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

This was the simplest choice. Metric closest to ones intuition, but surely not the optimal one.

‘Improvement’: showers are cigars rather than spheres as pt of particles produced in hadronic interaction is limited to ~ 300 MeV/c.

Transverse distance between cells less likely than the longitudinal one

2 2 20.05cutd x y z

Page 13: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

‘Transverse metric’ I

Significant improvement: better energy containment in the main cluster, smaller secondary cluster

Page 14: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.

‘Transverse metric’ II

Significant improvement: fewer secondary clusters, fewer left-over cells

Page 15: Adam Para, October 14, 2005 First look at PFA/clustering with RPC-based calorimeter Progress Report.