Top Banner
ACTIVE STABILIZATION ® ---------- LAPIDUS IMPLANT SYSTEM
8

ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

Jun 07, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

AC TIVESTABILIZ ATION®

- - - - - - - - - -

L A P I D U S I M P L A N T S Y S T E M

Page 2: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

O V E R V I E W

A C T I V E S T A B I L I Z A T I O N®

The Active Stabilization® System is the only hybrid plating system to replace static compression with dynamic

continuous compression. It is designed to address the most challenging foot & ankle procedures.

Active Stabilization®Bending & Rotational Stability Continuous Compression

P R O D U C T F E A T U R E S

Two distinct plate options

Plate and clip designed with 10˚ contour to match

patient anatomy

3x more effective at maintaining compression than a

traditional plate and cross screw*

Sterile recoverable instrumentation with EcoSMART®

*data on file

A NEW ERA IN BONE FIXATION

Page 3: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

I N S T R U M E N T A T I O NActive Stabilization® comes with sterile packed stainless steel instrumentation. Inserters are pre-loaded with implants

for each surgery.

Inserter Drill Guide Tamp

R O T A T I O N A L S T A B I L I T YThe Active Stabilization® system has

higher rotational stability compared

to a plate and cross screw.

COMPETITIVE PLATE + CROSS SCREW

Z-PLATE + CLIP 3.3

8.4

ROTATIONAL STABILIT Y AT 15°

VS.

TO

RQ

UE

(N

-M)

9

8

7

6

5

4

3

2

1 Cup Reamer

G A P R E C O V E R Y The Active Stabilization® system

presented full gap recovery, while

the plate with no clip did not

recover fully.

GAP AFTER LOADING WITH NO CLIP

GAP AFTER LOADING WITH CLIP

Active Stabilization® 4-Hole Plate + Clip

PL

AN

TA

R G

AP

(M

M)

4-Hole Plate + No Clip

1

2

3

4

5

6

7

1.56

0.00

VS.

T E S T I N G D A T A

Page 4: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

S P E C I F I C A T I O N S

NON-LOCKING LOCKING

SIZE RANGE 8-30mm* 8-30mm*

SIZE OPTION 3.0 & 3.5mm 3.0 & 3.5mm

*2mm increments

L Z - P L A T EAlpha, 18 and Beta, 18

L C - P L A T EAlpha, 18 and Beta, 18

S C R E W SNon-locking

18 x 18 18 x 20

INTERAXIS LENGTH 18mm 18mm

LEG LENGTH 18mm 20mm

REAMER SIZE 3.2mm 3.2mm

MAX CLIP THICKNESS 2.7mm 2.7mm

LEG WIDTH 1.8mm 1.8mm

CATALOG 7118-1818KT-C 7118-2020KT-C

H I M A X™ - C C L I P S

31.80

10º CONTOUR 10º CONTOUR

44.16

ALPHA, 18 BETA, 18

ACCEPTABLE CLIP SIZE 18 18

SLOT LENGTH / CLIP SIZE 18 18

OVERALL LENGTH 31.8 31.8

THICKNESS 1.7 1.7

CATALOG 7100-LZ18-A 7100-LZ18-B

ALPHA, 18 BETA, 18

ACCEPTABLE CLIP SIZE 18 18

SLOT LENGTH / CLIP SIZE 18 18

OVERALL LENGTH 44.16 44.16

THICKNESS 1.7 1.7

CATALOG 7100-LC18-A 7100-LC18-B

Page 5: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

A

B

CD E

F

G

HI

I N S T R U M E N T S I N C L U D E D I N E A C H K I TInstrumentation is packaged in sterile kits for efficiency

and convenience. After surgery, the instrumentation is

returned to CrossRoads® via the EcoSMART® Instrument

Recovery Service providing a significant cost savings

over typical disposable reusable instrument kits.

A Driver Handle F Driver Bits (2)

B Plate Bender (2) G Fixation Pins (2)

C 2.5mm Reamer H Locking Drill Guide (2)

D 2.0mm Reamer I Non-Locking Drill Guide

E Depth Gauge Probe

I N S T R U M E N T A T I O N

L O A N E R K I T S

C L I P S• 1 each, (18x18 Kit)

• 1 each, (18x20 Kit)

• 2 each Single Pack, (18x18,18x20)

P L A T E S• 2 each, Lapidus Z Alpha

• 2 each, Lapidus Z Beta

• 2 each, Lapidus C Alpha

• 2 each, Lapidus C Beta

• 1 each, Plate Instrument Kits

Page 6: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

L A P I D U S P L A T E S U R G I C A L T E C H N I Q U E

S T E P 0 1Plate SelectionAfter temporary fixation is applied,

trial to determine best anatomic fit.

Note: Trial with sterile plates.

S T E P 0 2Temporary FixationOnce plate is selected, use provided

fixation pins to secure plate and

confirm proper location.

S T E P 0 3Clip PreparationUse provided drill guide to prepare

holes for the HiMAX™-C Clip.

LC-PLATE

LC-PLATE

LC-PLATE LZ-PLATE

LZ-PLATE

LZ-PLATE

Page 7: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

S T E P 0 4Clip PlacementInsert HiMAX™-C Clip through the

plate and tamp flush.

S T E P 0 5Screw PlacementStarting with the most distal hole,

prepare screw holes and fill with

appropriate length non-locking

screws using non-locking drill guide.

Repeat until all holes are filled.

Note: Non-locking screws are recommended

LC-PLATE

LC-PLATE

LZ-PLATE

LZ-PLATE

*Patents Issued

Page 8: ACTIVE STABILIZATION - CrossRoads Extremity€¦ · LAPIDUS PLATE SURGICAL TECHNIQUE STEP 01 Plate Selection After temporary fixation is applied, trial to determine best anatomic

6055 Primacy Parkway, Suite 140, Memphis, Tennessee 38119

(901) 221-8406 | [email protected] | crextremity.com LA0319 REV A

A C T I V E S T A B I L I Z A T I O N . C O M