www.brainproducts.com Brain Products is proud to present actiCAP, another ground- breaking development aimed at raising EEG & ERP research to the next level. actiCAP combines active electrodes with a new type of integrated noise subtraction circuits delivering even lower noise levels than any other „normal“ active electrodes achieve. But that‘s not all: actiCAP can be connected to nearly any existing research EEG amplifier system. All of our amplifiers as well as most of our competitors’ amplifiers will work with actiCAP. If you decide to switch from passive to active electrodes you will no longer be forced to exchange your entire recording system. Simply keep your existing hardware, and the acquisition and analysis software you are used to working with and add the actiCAP to reduce your preparation time e.g. for 64 channels down to 5 minutes. The third generation of active electrodes Enlighten your Research Recording EEG the progressive way
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
ww
w.b
rain
pro
du
cts
.co
m
Brain Products is proud to present actiCAP, another ground-
breaking development aimed at raising EEG & ERP research
to the next level. actiCAP combines active electrodes with a
new type of integrated noise subtraction circuits delivering
even lower noise levels than any other „normal“ active
electrodes achieve.
But that‘s not all: actiCAP can be connected to nearly any
existing research EEG amplifier system. All of our amplifiers
as well as most of our competitors’ amplifiers will work with
actiCAP. If you decide to switch from passive to active electrodes
you will no longer be forced to exchange your entire recording
system. Simply keep your existing hardware, and the
acquisition and analysis software you are used to working with
and add the actiCAP to reduce your preparation time e.g. for 64
channels down to 5 minutes.
The third generation of active electrodes
Enlighten your ResearchRecording EEG the progressive way
Technical Specification:
Classification MDD 93/42/EEC, Class IIa
Patient Safety Protection class II, EMC tested, Type BF (DIN EN IEC 60601)
Safety requirements:
The third generation of active electrodes
actiCAP control software
ww
w.b
rain
pro
du
cts
.co
m
Amplification 1 (Tolerance < 0,001%)
Input impedance > 200 MOhm
Bandwith DC - 5000 Hz
Noise < 2 µV p.p. (0.1 - 35 Hz)
Dynamic range ±1000 mV
Impedance measurement frequency
30 Hz
Impedance working range 1 to 120 kOhm
Impedance display LED at electrode(colors: red, yellow, green)
Worldwide Caution:Limited by United States Law to Investigational Use. ID in accordance with 801.1 For research use only.
ISO 13485:2007
MDD 93/42/EEC
Components:actiCAP control box, Electrode sets (16-/32-/64-/96-/ 128-channel sets), Ground/reference electrode, Cap with holders, USB cable, Batteries & charger, Amplifier connection cable and adapter, acti-CAP control software, Manual