Acoustic Plaster Ceilings Product Data Sheet 228 Sound Absorption 100 mm / 400 mm Back of tile laminated with Acoustic fleece AV 2010 Sound Absorption α w = 0,80 Sound Absorbing Classification B Single number rating acc. ASTM C 423: SAA = 0,76 Classification acc. ASTM E 1264: NRC = 0,75 Ceiling Void: 400 mm Back of tile laminated with Acoustic fleece AV 2010 + Glass wool sound protection board SSP 1, 30 mm Sound Absorption α w = 0,90 Sound Absorbing Classification A Single number rating acc. ASTM C 423: SAA = 0,86 Classification acc. ASTM E 1264: NRC = 0,85 Ceiling Void: 400 mm Back of tile laminated with Acoustic fleece AV 2010 Sound Absorption α w = 0,75 Sound Absorbing Classification C Single number rating acc. ASTM C 423: SAA = 0,72 Classification acc. ASTM E 1264: NRC = 0,70 Ceiling Void: 100 mm Back of tile laminated with Acoustic fleece AV 2010 + Glass wool sound protection board SSP 1, 30 mm Sound Absorption α w = 0,95 Sound Absorbing Classification A Single number rating acc. ASTM C 423: SAA = 0,88 Classification acc. ASTM E 1264: NRC = 0,90 Ceiling Void: 100 mm Ultra-acoustic panel 12/25R DLV (round) Sound Absorption Value defined in accordance with DIN EN ISO 354 Sound Absorption evaluated in accordance with DIN EN ISO 11654 Thickness of the Board: d = 12,5 mm Density: 6,5 kg/m 2 Perforated Area: 33,9 % Building Material Classification according DIN 4102: A2, “non combustible” Fire performance according DIN EN 13501: A2-s1, d0 System setup: Covered with plaster carrier fleece and finished with a coating of VoglToptec ® acoustic plaster Nano SF Range of use: Creation of sound-absorbing areas Frequency in [Hz] 125 250 500 1000 2000 4000 Sound Absorption coefficient αp 0,50 0,75 0,70 0,80 0,80 0,85 Frequency in [Hz] 125 250 500 1000 2000 4000 Sound Absorption coefficient αp 0,30 0,75 0,95 0,95 0,90 0,90 Frequency in [Hz] 125 250 500 1000 2000 4000 Sound Absorption coefficient αp 0,15 0,45 0,80 0,90 0,75 0,80 Frequency in [Hz] 125 250 500 1000 2000 4000 Sound Absorption coefficient αp 0,55 0,80 0,80 0,95 1,00 0,95 Sound Absorption coefficient α s Sound Absorption coefficient α s Sound Absorption coefficient α s Sound Absorption coefficient α s Industriestrasse 10, 91448 Emskirchen, Phone +49(0)9104-825-0, Fax +49(0)9104-825-250, [email protected] Phone +49(0)9104-825-121, Fax +49(0)9104-825-252, [email protected] Vogl Deckensysteme GmbH Order service 11/ 14 Frequency in [Hz] Frequency in [Hz] Frequency in [Hz] Frequency in [Hz]
1

Acoustic Plaster Ceilings - Vogl Deckensysteme · Acoustic Plaster Ceilings Product Data Sheet 228 Sound Absorption 100 mm / 400 mm Back of tile laminated with Acoustic fleece AV

Sep 24, 2019

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Acoustic Plaster Ceilings - Vogl Deckensysteme · Acoustic Plaster Ceilings Product Data Sheet 228 Sound Absorption 100 mm / 400 mm Back of tile laminated with Acoustic fleece AV

Acoustic Plaster Ceilings Product Data Sheet 228 Sound Absorption 100 mm / 400 mm

Back of tile laminated withAcoustic fleece AV 2010 Sound Absorption αw = 0,80Sound Absorbing Classification B

Single number rating acc. ASTM C 423: SAA = 0,76Classification acc. ASTM E 1264: NRC = 0,75

Ceiling Void: 400 mm

Back of tile laminated withAcoustic fleece AV 2010 +Glass wool sound protection board SSP 1, 30 mm Sound Absorption αw = 0,90Sound Absorbing Classification A

Single number rating acc. ASTM C 423: SAA = 0,86Classification acc. ASTM E 1264: NRC = 0,85

Ceiling Void: 400 mm

Back of tile laminated withAcoustic fleece AV 2010 Sound Absorption αw = 0,75Sound Absorbing Classification C

Single number rating acc. ASTM C 423: SAA = 0,72Classification acc. ASTM E 1264: NRC = 0,70

Ceiling Void: 100 mm

Back of tile laminated withAcoustic fleece AV 2010 +Glass wool sound protection board SSP 1, 30 mm Sound Absorption αw = 0,95Sound Absorbing Classification A

Single number rating acc. ASTM C 423: SAA = 0,88Classification acc. ASTM E 1264: NRC = 0,90

Ceiling Void: 100 mm

Ultra-acoustic panel 12/25R DLV (round)

● Sound Absorption Value defined in accordance with DIN EN ISO 354● Sound Absorption evaluated in accordance with DIN EN ISO 11654

Thickness of the Board: d = 12,5 mmDensity: 6,5 kg/m2

Perforated Area: 33,9 % Building Material Classification according DIN 4102: A2, “non combustible” Fire performance according DIN EN 13501: A2-s1, d0

System setup:Covered with plaster carrier fleece and finished with a coating of VoglToptec® acoustic plaster Nano SF

Range of use:Creation of sound-absorbing areas

Frequency in [Hz] 125 250 500 1000 2000 4000

Sound Absorption coefficient αp 0,50 0,75 0,70 0,80 0,80 0,85

Frequency in [Hz] 125 250 500 1000 2000 4000

Sound Absorption coefficient αp 0,30 0,75 0,95 0,95 0,90 0,90

Frequency in [Hz] 125 250 500 1000 2000 4000

Sound Absorption coefficient αp 0,15 0,45 0,80 0,90 0,75 0,80

Frequency in [Hz] 125 250 500 1000 2000 4000

Sound Absorption coefficient αp 0,55 0,80 0,80 0,95 1,00 0,95

Sou

nd A

bsor

ptio

n co

effic

ient

αs

Sou

nd A

bsor

ptio

n co

effic

ient

αs

Sou

nd A

bsor

ptio

n co

effic

ient

αs

Sou

nd A

bsor

ptio

n co

effic

ient

αs

Industriestrasse 10, 91448 Emskirchen, Phone +49(0)9104-825-0, Fax +49(0)9104-825-250, [email protected] +49(0)9104-825-121, Fax +49(0)9104-825-252, [email protected]

Vogl Deckensysteme GmbHOrder service11/ 14

Frequency in [Hz]

Frequency in [Hz]

Frequency in [Hz]

Frequency in [Hz]