Top Banner
The organizers of this symposium express our deepest thanks to Prof. Alec Marantz and MIT Department of Linguistics and Philosophy for offering to use this lecture room for this symposium and for helping us to make various arrangements for this symposium. We also thank VMS medtech for their courtesy in providing lunch and refreshments. Acknowledgements
35

Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Apr 04, 2018

Download

Documents

duongcong
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

The organizers of this symposium express our deepest thanks toProf. Alec Marantz and MIT Department of Linguistics andPhilosophy for offering to use this lecture room for this symposium and for helping us to make various arrangements for this symposium.

We also thank VMS medtech for their courtesy in providing lunch and refreshments.

Acknowledgements

Page 2: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Comparison between adaptive and non-adaptive spatial filter performances

Kensuke Sekihara1, Maneesh Sahani2, Srikantan S. Nagarajan3

1Department of Engineering, Tokyo Metropolitan Institute of Technology2Keck Center for Integrative Neuroscience, University of California, San Francisco

3Department of Radiology, University of California, San Francisco

Spatial filtering in BiomagnetismSatellite Symposium of Biomag 2004Boston, August, 2004

Page 3: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

This talk compares the adaptive spatial filters such as minimum-variance spatial filter with the minimum-norm-based tomographic reconstruction methods, by formulating them as non-adaptive spatial filters.

•Bias in the reconstructed source location in the absence or presence of noise.

•Spatial resolution.

•Influence of source correlation.

Performance measures:

Page 4: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

( )

( ) data vector: (t) =

( )

1

2

M

b t

b t

b t

⎡ ⎤⎢ ⎥⎢ ⎥

• ⎢ ⎥⎢ ⎥⎢ ⎥⎣ ⎦

b

Definitions

data covariance matrix: ( ) ( )Tb t t• =R b b

= [ , ,

source magnitude: ( , )

source orientation: ( ) ( ) ( ) ( )]

• Tx y z

s t

,t ,t ,t ,t

r

r r r rη η ηη

( ) 1b t( ) 2b t ( ) Mb t

Page 5: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

y

x

sx

l1x l2

x l3x

lMx

z

y

x

l1z l2

z l3z lM

z

z sz

y

x

l1y l2

y l3y lM

y

z sy

|sx|=|sy|=|sz|=1

( ) ( ) ( )

( ) ( ) ( )( ) =

( ) ( ) ( )

1 1 1

2 2 2

( )

, ( ) ( ) ( )

( )

x y z

xx y z

y

zx y zM M M

l l l

l l l

l l l

η

η

η

⎡ ⎤⎡ ⎤⎢ ⎥⎢ ⎥⎢ ⎥

= ⎢ ⎥⎢ ⎥⎢ ⎥⎢ ⎥⎢ ⎥⎢ ⎥ ⎣ ⎦

⎣ ⎦

r r rr

r r rL r l r L r r

rr r r

Sensor lead field

Page 6: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Spatial filter for bioelectromagnetic source reconstruction

2

( , ) ( , ) ( ) ( , ) ( )

ˆmax ( , ) max ( , ) ( , )

= ≈⇑

= =η η

r w r η b w r η b

η r w r η R w r η

T Topt

Topt b

s t t t

s t

Scalar spatial filter

ˆ ˆ ˆ ˆ[ ( ), ( ), ( )] ( , ) [ ( ), ( ), ( )] ( )T Tx y z x y zs s s s t t= =r r r η r w r w r w r b

Vector spatial filter

The spatial filter incorporate the 3D vector nature of sources

Page 7: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Adaptive spatial filter

Non-adaptive spatial filter

is data independent( )w r

is data dependent( )w r

Page 8: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

( ) ( )1N N, ,⎡ ⎤= ⎣ ⎦L L r L r

Then TN N=G L L

Gram matrix is usually calculated by introducing pixel grid jG r

jr

Define Gram matrix =: ( ) ( )T d∫G G L r L r r

Define composite lead field matrixfor all pixel locations such that

Gram Matrix

Page 9: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Non-adaptive spatial filters

1( ) ( )−=w r G l r

Minimum-norm (Hamalainen)

Weight normalized minimum norm (Dale et al.)

1 2( ) ( )/ ( ) ( )T− −=w r G l r l r G l r

sLORETA (Pasucual-Marque)

1 1( ) ( )/ ( ) ( )T− −=w r G l r l r G l r

( ) ( ) opt=l r L r η

Page 10: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

1 1( ) ( )/[ ( ) ( )]Tb b− −=w r R l r l r R l r subject to ( ) 1min T

b =⇐ T

ww R w w l r

Adaptive spatial filters

Minimum variance

Minimum variance with normalized lead field

1 1( ) ( )/[ ( ) ( )]Tb b− −=w r R l r l r R l r subject to ( ) ( )min T

b⇐ =T

ww R w w l r l r

Weight-normalized minimum variance (Borgiotti-Kaplan)

1 2( ) ( )/ ( ) ( )Tb b− −=w r R l r l r R l r subject to 1min T

b =⇐ T

ww R w w w

( ) ( )/ ( )=l r l r l r

Page 11: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Bias of estimated source locations

We first take a look at the bias of reconstructed source locations for these adaptive and non-adaptive spatial filters.

Page 12: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Resolution kernel

( ) ( ) ( ) ( ) ( ) ( )

( )= (( )

)T

T

' s ' d 's ' s ' d '

ˆ'

s,

= ∫→ = ∫

b l r r rr w r l r r r

r w br

rrR⇑

Resolution kernel analysis

1 1 1ˆ( ') ( ' ) ( ) ( , ') ( ' ) ' ( , )δ δ= − ⇒ = − =∫r r r s r r r r r r r rs dR R

No location bias Resolution kernel peaks at r1

1 1 1( , ) ( , )>R Rr r r r

A single source at 1r

Page 13: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

The condition: 1 1 1( , ) ( , )>R Rr r r r

The source at has lead field vector 1 1: ( )=r f f L r η

Minimum-norm

Weight normalized minimum norm

sLORETA

1 1− −>fG f lG f ( ( ) )=l L r ηopt

1 1

2 2T T

− −

− −>

fG f lG ff G f l G l

1 1 1 2( )( ) ( )T− − −>fG f l G l lG f

Schwartz inequality valid because G is a positive definite matrix

Non-adaptive spatial filters

Page 14: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

The condition: 1 1 1( , ) ( , )>R Rr r r r

Minimum-variance

Minimum variancewith normalized lead field

Weight-normalizedminimum variance

2

cos( , ) 11 [1 cos ( , )]α

<+ −

f l fl l f

Adaptive spatial filters

2

cos( , ) 11 [1 cos ( , )]α

<+ −

l fl f

2

cos( , ) 11 ( 2)[1 cos ( , )]α α

<+ + −

l fl f

022 21 0( / ) ( ), cos( , ) 1

T

Mα σ σ= > ≤ = ≤l f

f l ff l

Page 15: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

148-channel sensor array

single sources

y (cm)z

(cm

)0-5 5

-5

-10

-15

Page 16: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Minimum norm(normalized leadfield)

Minimum norm

Weight normalized minimum norm

sLORERA

Minimum variance

Minimum variance(normalized lead field)

Reconstruction results of this single source

The cross mark indicates the source location

Page 17: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Effect of noise on location bias

Condition for no location bias:

2 22 2 2 21 1 1 0 1 1 1 0( , ) ( ) ( , ) ( )σ σ σ σ+ > +R Rr r w r r r w r

noise power, signal power, input SNR: 22 2 2 20 1 1 0: : ( / )σ σ α σ σ= f

sLORETA:

wh ere 2

1

2 1

1

2

2

[1 ( )/ ] cos ( , | )( )

( )1,[1 ( )/ ( , )]

r lf w r

rr

r rf ΩΩ α

Ω α−+

< =+

GR

Minimum variance with normalized lead field

2

1 11 [1 cos ( , )]α

<+ − l f

Page 18: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

sLORETAMinimum-variance

(normalized lead field)

2

1 11 [1 cos ( , )]α

<+ − l f

(148)Mα =

4 (592)Mα =

8 (1184)Mα =

Page 19: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Spatial resolution comparison

When there is no location bias, the mail-lobe width of the kernelcan be a measure of spatial resolution.

Point spread function: 1 1 1( ) ( , )/ ( , )φ = R Rr r r r r

sLORETA: 11

1 1( ) cos( , | )( )

( )( )

T

T Tφ

− −

− ==l G f

f G f l Gf G

lr l

Minimum variance: 2[1 cos ( ,cos( , )( )

1 )]αφ =

+ − lff

lr

Because α is a large value, this part causes a rapid decay of the point spread function

Page 20: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

sLORETAMinimum-variance

Point spread functionz

(cm

)

y (cm)0-5 5

-5

-10

-15

Page 21: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Reconstruction experiments when two sources exist

sLORETAMinimum-variance

(normalized lead field)Source distance

4.2cm

2.1cm

1.4cm

input SNR: Mα =

Page 22: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Source correlation influence for adaptive spatial filters

1

1

[ ]( ) ( )

[ ]pqT S

p qppS

−=R

w r l rR

source covariance matrix, :the element of 1 1: [ ] ( , )pqS SSp q− −R R R

( ) ( )Tpqp q δ=w r l r

When sources are correlated with the th source,Q p1

11

[ ]( , ) ( , ) ( , )

[ ]

Q pqSp qp q ppS

s t s t s t−

−=

= + ∑R

r r rR

spatial-filter output leakages from other correlated sources

(Sources are uncorrelated)

(Sources are partially correlated)

Page 23: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Signal cancellation

11 1 2

2

22 1 2

1

( , ) ( , ) ( ) ( , )

( , ) ( ) ( , ) ( , )

s t s t s t

s t s t s t

α µα

α µα

= −

= − +

r r r

r r r

⇓2 2 2

1 1

2 2 22 2

( , ) (1 ) ( , )

( , ) (1 ) ( , )

s t s t

s t s t

µ

µ

= −

= −

r r

r r

Source power decreases by a factor of 2(1 )µ−⇑

When two correlated sources exist

source correlation coefficient

Page 24: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Reconstruction experiments when two correlated sources exist

sLORETAMinimum-variance

(normalized lead field)Correltioncoefficient

0

0.85

0.98

Page 25: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

sLORETAMinimum-variance (normalized lead field)

Auditory somatosensory response

Page 26: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

sLORETAMinimum-variance (normalized lead field)

Somatosensory response (right median nerve stimulation)

Page 27: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Summary•The resolution kernel analysis validates the previous findings that sLORETA has no location bias. Minimum-variance filter has no location bias, if it is used with normalized lead field.

•Noise may cause the location bias for sLORETA. Minimum-variance spatial filter with normalized lead field has no location bias even in the presence of noise.

•Minimum-variance filter generally has significantly higher spatial resolution than sLORETA.

•Performance of sLORETA is not affected by source correlation.

•High spatial resolution of the minimum-variance filter is demonstrated by the somatosensory and somatosensory-auditory applications.

Page 28: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Summary•The resolution kernel analysis validates the previous findings that sLORETA has no location bias. Minimum-variance filter has no location bias, if it is used with normalized lead field.

•Noise may cause the location bias for sLORETA. Minimum-variance spatial filter with normalized lead field has no location bias even in the presence of noise.

•Minimum-variance filter generally has significantly higher spatial resolution than sLORETA.

•Performance of sLORETA is not affected by source correlation.

•High spatial resolution of the minimum-variance filter is demonstrated by the somatosensory and somatosensory-auditory applications.

Page 29: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Summary•The resolution kernel analysis validates the previous findings that sLORETA has no location bias. Minimum-variance filter has no location bias, if it is used with normalized lead field.

•Noise may cause the location bias for sLORETA. Minimum-variance spatial filter with normalized lead field has no location bias even in the presence of noise.

•Minimum-variance filter generally has significantly higher spatial resolution than sLORETA.

•Performance of sLORETA is not affected by source correlation.

•High spatial resolution of the minimum-variance filter is demonstrated by the somatosensory and somatosensory-auditory applications.

Page 30: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Summary•The resolution kernel analysis validates the previous findings that sLORETA has no location bias. Minimum-variance filter has no location bias, if it is used with normalized lead field.

•Noise may cause the location bias for sLORETA. Minimum-variance spatial filter with normalized lead field has no location bias even in the presence of noise.

•Minimum-variance filter generally has significantly higher spatial resolution than sLORETA.

•Performance of sLORETA is not affected by source correlation.

•High spatial resolution of the minimum-variance filter is demonstrated by the somatosensory and somatosensory-auditory applications.

Page 31: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Summary•The resolution kernel analysis validates the previous findings that sLORETA has no location bias. Minimum-variance filter has no location bias, if it is used with normalized lead field.

•Noise may cause the location bias for sLORETA. Minimum-variance spatial filter with normalized lead field has no location bias even in the presence of noise.

•Minimum-variance filter generally has significantly higher spatial resolution than sLORETA.

•Performance of sLORETA is not affected by source correlation.

•High spatial resolution of the minimum-variance filter is demonstrated by the somatosensory and somatosensory-auditory applications.

Page 32: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Collaborators

Kanazawa Institute of TechnologyHuman Science Laboratory

Dr. Isao Hashimoto

University of MarylandLinguistics and Cognitive Neuroscience Laboratory

Dr. David Poeppel

Massachusetts Institute of Technology,Department of Linguistics and Philosophy

Dr. Alec Marantz

Page 33: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

http://www.tmit.ac.jp/~sekihara/

Visit

The PDF version of this power-point presentation as well as PDFs of my recent publications are available.

Page 34: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

Generate many random dipoles in a volume:

-4 < x < -1, 1< x <4-4 < y < 4

-10 < z < -2

Number of noise random dipoles: 200

The power of noise dipoles is set at

0.005 second source power

or 0.025 second source power

:NP

×

×

Time courses of the noise sources are incoherent to each other.

source planex=0

z

yx8cm

8cm

8cm

Page 35: Acknowledgements - Tokyo Metropolitan University · Spatial filtering in Biomagnetism Satellite Symposium of Biomag 2004 Boston, August, 2004. ... Microsoft PowerPoint - talk_sympo.ppt

sLORETAMinimum-variance

(normalized lead field)

No noise source

Noise source power:0.005

Noise source power:0.025

Violation of the low-rank signal assumption