Top Banner
Accommodation module including helideck for 50 persons Technical specification
24

Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

May 11, 2018

Download

Documents

phamdang
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

Accommodation module including helideck for 50 persons

Technical specification

Page 2: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

2

BRIEF DESCRIPTION

4-level accommodation module for 50 persons

Complete steel structure. Total weight of module is approx. 551 tonnes

Dimensions (LxBxH): 20.8 m x 10.8 m x 20,3 m (excl stairways/platform)

15 cabins for 2 persons (12,2/9,25 m2)*

5 cabins for 4 persons (13,9/10 m2)*

Aluminium Helicopter deck on top of module designed for Sikorsky S-61N

Fully equipped

Classified as “SAFE AREA”

Classification and verification by Lloyds Register

* = gross/nett cabin area

The accommodation module is completely outfitted, ready to use and includes a

top mounted helideck. It is designed and built for 50 persons but can be modified

on request. This technical specification describes the scope of delivery of the

complete accommodation module.

Page 3: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

3

General

Design criteria

The design of the module is based on the following international rules, regulations and specifications:

SOLAS – consolidated edition 2004

NMD regulations for Mobile Offshore Units

Lloyd’s Register of Shipping; MOU

International Maritime Organisation (IMO) 1982 ed.

IMO Resolution A.486 (XII)

International Electrical Code (IEC)

DNV-OS-C101 (Structural only)

Purpose specific criteria for oa HVAC, Safety design philosophy, Living Quarter and Helicopter-deck specification, General design and outfitting.

Classification

Classification and verification by Lloyds Register The accommodation module is classified as a ”SAFE AREA”. The full envelop of the accommodation module is fire rated for a hydrocarbon free environment.

Geometry

The footprint of the Accommodation module (excluding walkways and landing platform) is 20.8 m x 10.8 m. The lay down area adds another 8 metres to the length. Height from base to top of 4th level is 15.1m. Overall height including Helicopter deck is 20.3 m from base. The module is designed to be supported on minimum four points; footprint 12,0 m x 10,5 m. The total weight of the module is 551 metric tons.

General Layout

The module comprises of four accommodation levels. The lowest level has a lay-down area for two 10 feet containers. On the roof level are located a plant room and a LER. On top of that is an aluminium helicopter deck. Two stair towers are fitted, one on each side of the module. All utility connections are located at the bottom of the utility shaft and in the control room/LER, allowing for easy hook-up of systems. Levels 2 and 3 are dedicated for cabins while levels 1 and 4 are arranged for galley/ messroom and recreation, offices, control room.

Documentation

The accommodation module will be delivered with complete as-built documentation package including oa drawings, test reports, certificates, weight report, Installation & Operation Manual.

Accommodation module

Page 4: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

4

Structural

General

The accommodation module is designed and constructed as a four level building with a plant room and LER at roof level. The helideck support structure is an integrated part of the module’s skeleton. Two exterior stair towers are provided from 1st level to helideck level. Roof and lay down area are provided with railing. Primary steel is S335 J2G3 and secondary steel S235 J2 (with appropriate certification). Accommodation is fully welded by qualified welders and approved welding procedures. 10% (random) MPI is executed on major beams.

Helideck

The helicopter deck is constructed from seawater resistant aluminium and has an octagonal shape inscribed in a circle of 22.2 meter. It is fitted with safety netting and a drain gutter around its perimeter. The support structure is constructed of hot rolled carbon steel beams. Helideck is certified for a Sikorsky S61N.

Lifting arrangement

The accommodation module and helideck can be lifted as one module. The 551 tonnes module is lifted from lifting points at the top of the accommodation structure (roof). The aluminium helideck is executed with hatches to accommodate access for the lifting gear. Lifting columns and eyes are 100% MPI tested.

Protective coating

All steel is blasted to SA 2½ and coated in shop primer. External steel is coated with 3-layer system; internal steel is coated with a 1-layer system.

Accommodation construction with exterior stair tower

Helideck with support structure

Lifting of module from quayside with floating crane

Page 5: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

5

Architectural

General specification

Inside of bulkheads and decks are provided with insulation and applied with interior wall panels where applicable. Floors (steel or insulated tiles) are applied with levelling screed and finished with either vinyl or seamless epoxy (in wet areas). All rooms are provided with a cassette type false ceiling system. Windows are welded marine type and provided with roller blinds or curtains. Internal stairway reaching from 1st to 4th level provided with st.st. handrail on both sides.

Layout

The layout of the accommodation is as described below. Please find attached layouts and inventory list for more details.

Level 1

Locker room male Locker rooms with 52 steel lockers, benches, hand wash basin, one shower, a urinal and two toilets

Locker room Female Locker room with 10 steel lockers, a bench, hand wash basin, one shower and one toilet.

Tea Room Tea room (12 m2) with benches, a phone booth and a Kitchenette.

Mess Room Mess room (45 m2) with 4 off 6-person tables, a serving counter, lockable cupboard and overhead screen.

Janitor Janitor room with a sink (and tap) and a rack with shelving.

Galley Fully equipped Galley (35 m2), equipment as detailed in inventory list.

Dry Store & Cold Room / Freezer Fitted with Aluminium shelving

Locker Room Male

Mess Room

Galley

Freezer Room

Page 6: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

6

Level 2

Laundry Laundry room (12,0 m2) with oa washing machine, tumble dryer, ironing board, washing bin and shelves

Fitness Fitness area (12 m2) with fitness equipment.

Linen Store Linen store room (4 m2) with steel shelving.

Fireman’s Outfit store In corridor next to stairway.

10 x 2-Persons Cabins 10 off 2-person cabins (9,25 m2 excl bathroom), each cabin fitted with a double bunk bed, a desk (1.4 x 0.6 m) with chair, an easy chair, a cupboard, a locker for immersion suit and a bathroom.

Level 3

Health Office Health office (14,7 m2) with desk, chair, bathroom, cupboard, inflatable bath, medicine cupboard, examining couch and file cabinet

5 x 4-person cabin 5 off 4-person cabins (10 m2 excl bathroom), each cabin fitted with two double beds (top is fold-away), a desk (1.4 x 0.6 m) with chair, an easy chair, a cupboard, a locker for immersion suit and a bathroom.

5 x 2-person cabin 5 off 2-person cabins (9,25 m2 excl bathroom), each cabin fitted with a double bunk bed, a desk (1.4 x 0.6 m) with chair, an easy chair, a cupboard, a locker for immersion suit and a bathroom.

Linen Store Linen store room (4 m2) with steel shelving.

Fireman’s Outfit store In corridor next to stairway.

2-person cabin

3D topview of 2 person cabin

Health office

4-person cabin

Page 7: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

7

Level 4

Recreation Day room Recreation day room (31 m2) with couches, easy chairs, coffee table, TV cupboard with TV / DVD / Stereo, book shelves with internet desk, phone booth and kitchenette with sink and mixing tap

Recreation Smokers Day room Recreation smokers day room (25 m2) with couches, easy chairs, coffee table, TV cupboard with TV / DVD / Stereo, book shelves with internet desk, phone booth and kitchenette with sink and mixing tap

Control Room L-shaped Control room (60 m2) with false floor (500 mm). Room is not outfitted at present.

Heli Lounge / Office Office area (12 m2) with two desks with chair, two file cabinets and a Cupboard for PSP.

Office 1 Office area (12 m2) with two desks with chair, a file cabinet and a white board.

Office 2 Office area (12 m2) with a corner desk with chair, a meeting table with six chairs, video conferencing system and white board.

Toilets Two separate toilets in the corridor.

Recreation day room

Control room with false floor

Heli lounge / office

Office / meeting room

Page 8: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

8

Safety & Fire Protection

Fire main system

A hose reel system is fitted throughout the accommodation at all levels. Two hose reels per level and two hose reels for the helicopter deck. Fire water is to be externally supplied.

Fire & Smoke detecting system

On every level fire detectors and smoke detectors are installed

Portable extinguishers

Various classes A, B and C, (weights from 5 to 12kg) portable extinguishers are distributed throughout the module. For the helicopter deck 2 off 10 kg CO² extinguishers are provided.

Galley hood protection system

A R102 system is installed in the galley hood.

Safety Signs

Safety signs (in the English language) and overall safety plan are installed inside the accommodation module. Corridors have fluorescent safety striping on low level.

Safety equipment

The module is fitted with the following safety equipment: Stretcher / 4 off Fireman outfit’s / Supplement for firemen’s outfit / Helicopter deck rescue kit / First aid box / 4 off Eye wash bottles / Fire blankets.

Helicopter deck foam system

A helicopter deck AFFF-foam system is installed. A twin agent 250 kg dry powder and 250 litres of concentrated foam are located near the helideck. (As per NMD)

Fire hose reel and fire detector in corridor

AFFF foam system near helideck

Stairway with st.st. handrailing and fluorescent striping

Page 9: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

9

HVAC

Design Conditions

The HVAC system is designed for the following conditions: Summer Outside: +35º C / 70% RH Inside: +29º C / 50% RH Inside: +29º C / 50% RH (Galley-Laundry) Winter Outside: -20º C / 0% RH Inside: +20º C / 50% RH Inside: +25º C / 50% RH (Health room) Inside: +20º C / 60% RH (Galley-Laundry) (At a relative wind speed of 12 m/sec) The temperatures are controlled by local humidity- and heat-controllers. Fresh air amount for HVAC in accommodation is 50%, 30m³/hr per person (according NMD rules). The maximum outside air temperature for cooling air for the condensers is +35º C

Noise levels

Noise level of unit as per IMO resolution A,468(XII) at 70 DBa

Air Handling Unit

The Air handling unit (AHU) for the HVAC system is located on the roof of the module in the plant roomn with evaporator/ACCU unit outside. AHU make/type is Heinen&Hopman SALOR.

AHU evaporator/ACCU-unit on accommodation roof

AHU in plant room on accommodation roof

Page 10: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

10

Piping Systems

General specification

All systems have flanged ends at the bottom of the utility shaft for hook up purposes. All galvanised systems are hot-dip galvanised to EN ISO 1461. All pipes are concealed as much as practical. The following major piping systems are installed:

Potable hot and cold water system

Systems are executed as ring systems with branches to the various users. All pipes and fittings from soldered copper and insulated. Hot and cold water are to be externally supplied.

Sewage system

Consists of two systems; Black-water which serves the toilets and Grey-water for all other systems and facilities. Pipes and fittings from U-PVC materials. Flanged hook-up point is galvanised steel.

Helicopter deck Drain System

Helicopter deck gutter is connected to galvanised steel drain pipe running outside the module.

Fire main system

Comprising of hose reel system and helicopter deck fire system, see Safety & Fire Protection

Intermediate deck of utility shaft

Bathroom in cabin

Page 11: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

11

Electrical & Instrumentation

General

Power, HVAC, lighting and small power installations are based on incoming (emergency-) power supply of 440 Volt, 3 phase, 60 Hertz. No UPS is foreseen. See attached single line diagram and load list for distribution panels and electrical details. Distribution panels are located in the plant room on the roof.

Cable trays

Cable trays and support systems are made of hot dip galvanised steel.

Fire & gas detection system

All detectors, alarm sounders, flash lights, manual call points, telephones, PA/GA equipment are installed and terminated at interface junction box at the bottom of utility shaft or loose to the control room.

Telecom- / Data- / Alarm-installations

PA speakers, RTV- and telephone sockets are installed. No Data sockets, network provisions or central antenna system is foreseen.

Lighting and small power installation

Lighting and small power installation is installed throughout the module, comprising of normal lighting fixtures, emergency lighting fixtures (with battery back-up) and required lighting switches / socket outlets External lighting provided at staircases and walkway at 4th level with termination at interface junction box.

Helicopter deck lighting

Helideck lighting system consists of 6 floodlights and 25 perimeter lights.

Navigation lighting

No navigation lights are foreseen on the module.

Distribution panels in plant room

Telephone hood in recreation day room

Lighting and emergency lighting in Messroom

Page 12: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

Attachments

Layout Level 1

Layout Level 2

Layout Level 3

Layout Level 4

Layout Roof Level

Lifting plan

Framing plan

P&ID Grey and Black water

P&ID Firewater

P&ID Potable water

Single line diagram

Electrical Load List

Page 13: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 14: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 15: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 16: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 17: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 18: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 19: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 20: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 21: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 22: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 23: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can
Page 24: Accommodation module including helideck for 50 persons · DNV-OS-C101 (Structural only) Purpose specific criteria for oa HVAC, Safety ... The accommodation module and helideck can

ELECTRICAL LOADLIST POWER DISTRIBUTON 440V AC THREE PHASE