outputs to EN442ABUNAcode width height no. of projection tappings c/c Btu/hr watts
mm mm tubes mm mm Δ 50˚C Δ 50˚CSON1 164 1800 4 86-98 70 616 180SON2 236 1800 6 86-98 145 886 260SON3 308 1800 8 86-98 215 1156 339SON4 380 1800 10 86-98 290 1426 418
Dual fuel factory fitted. Wall fixed 1⁄2" tappings facing down. Suitable for any hot water system.Towel rail accessories can be purchased for this product.
outputs to EN442ANGARA tappings width c/c tappings optional
code width height projection wall to centre vertical tubes c/c additional Btu/hr wattsmm mm mm mm mm mm towel rail Δ 50˚C Δ 50˚C
Tube size: Frame = 31.75mm; cross tubes = 25.4mm. Sealed electric, code becomes ERR plus size.Wall fixed, 1⁄2" tappings. Painted units suitable for closed circuit applications only. Plated units suitable for any hot water system.Chrome outputs reduce by approximately 35%. Actuals available on request.
Dual fuel factory fitted. Wall fixed 1⁄2" tappings facing down. Suitable for any hot water system.*Approx output - NPD.
HEATER KITsize heater kit heater kit
ref white ref chrome1/45 to 3 MHK300 MHK2004/45 to 6 MHK300 MHK2007/45 to 9 MHK500 MHK500
20628 spec pages:Layout 1 6/2/08 11:43 Page 1
Sp
ecifica
tion
s5
7outputs to EN442AWE
width height tappings width c/c tappings tappings pipe centres code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr watts
mm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚CB27/1 693 955 140 114 610 550 110 450* 761 223B27/2 845 955 140 114 762 702 110 602* 935 274B27/3 997 955 140 114 914 854 110 754* 1109 325B27/4 1150 955 140 114 1067 1007 110 907* 1286 377
Dual fuel factory fitted. Tube size: 31.75mm. Floor mounted, integral wall stays, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
B30 693 991 221 N/A 610 550 110 450* 1109 325
Dual fuel factory fitted. Tube size: 31.75mm. Floor mounted, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
outputs to EN442CAYUTAcode width height projection tappings c/c Btu/hr watts
mm mm mm mm Δ 50˚C Δ 50˚CCNT1 700 1344 208-218 660 2992 877
Dual fuel factory fitted. Wall fixed 1⁄2" tappings facing down. Suitable for any hot water system.
20628 spec pages:Layout 1 6/2/08 11:43 Page 2
58
Sp
ecifica
tion
soutputs to EN442CHAMPLAIN
tappings wall width c/c tappings face tappings floor pipe centrescode width height projection to centre vertical tube to face to centre for valves Btu/hr watts radiator
mm mm mm mm mm mm Δ 50˚C Δ 50˚C h x wADA1 676 931 205 105 645 576 110 469 1320 387 500 x 455
code width height projection of c/c side Btu/hr watts4 column mm mm mm sections mm Δ 50˚C Δ 50˚C12-4060 600 600 170 12 600 3402 99716-4060 800 600 170 16 800 4537 133020-4060 1000 600 170 20 1000 5671 1662
Other sizes are available, please refer to Design Radiators technical guide.Wall fixed, 1⁄2" tappings. Closed circuit applications only.
outputs to EN442COLUMN Bench Seatcode width height projection number of tappings c/c Btu/hr watts
4 column mm mm mm sections mm Δ 50˚C Δ 50˚C23-05-6180 2150 472 365 5 407 6196 181623-06-6180 2150 522 365 6 457 7230 2119
inc. seat inc. seat inc. seatOther sizes are available, please refer to Design Radiators technical guide.Floor mounted, 1⁄2" tappings. Closed circuit applications only.
outputs to EN442COLUMN Verticalnumber tappings
code width height projection of c/c side Btu/hr wattsmm mm mm sections mm Δ 50˚C Δ 50˚C
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Tube size: 31.75mm. Floor mounted, integral wall stays, 3⁄4" internal tappings. Suitable for any hot water system.*Using MYSON valves.
outputs to EN442CUBANGOcode width height no. of projection tappings c/c Btu/hr watts
mm mm tubes mm mm Δ 50˚C Δ 50˚CCAN1/5 600 1190 5+5 86-98 500 1092 320CAN1/7 600 1190 7+3 86-98 500 1092 320CAN2/5 600 1800 5+5 86-98 500 1426 418CAN2/7 600 1800 7+3 86-98 500 1426 418
Dual fuel factory fitted. Wall fixed 1⁄2" tappings facing down. Suitable for any hot water system.Towel rail accessories can be purchased for this product.
20628 spec pages:Layout 1 6/2/08 11:43 Page 3
Sp
ecifica
tion
s5
9
outputs to EN442DÉCOR H11tappings
code width height projection c/c side Btu/hr wattsmm mm mm mm Δ 50˚C Δ 50˚C
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr watts h x wmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C mm
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ50˚C
Tube size: frame = D shape 40x30mm; cross tube = oval 30x20mm. Sealed electric, code becomes ECM plus size.Wall fixed, 1⁄2" tappings. Painted units suitable for closed circuit applications only. Plated units suitable for any hot water system.Chrome outputs reduce by approximately 35%. Actuals available on request.
ELECTRARADheat
code height length projection weight outputsmm mm mm kg watts
Dual fuel factory fitted. Projection: dependent upon wall stays. Wall to centre of tapping: dependent upon wall stays. Tube size: S2/1 to S2/3 = 25.4mm; S2/4 to S2/6 = 31.75mm. Floor mounted, wall stays optional extra, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves. **Approx output - NPD.
INNOKO Curvedcode width height projection rated
mm mm mm wattsPETCL 450 500 95 40PETCR 450 500 95 40
Left hand and right hand options available.
INNOKO Straightcode width height projection rated
mm mm mm wattsPETSL 450 500 84 40PETSR 450 500 84 40
Left hand and right hand options available.
outputs to EN442INTERLUDEcode width height projection tappings c/c Btu/hr watts
mm mm mm mm Δ 50˚C Δ 50˚CINT1 500 530 108-123 447 1007 295INT2 500 905 108-123 447 1604 470INT3 500 1605 108-123 447 2788 817
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Tube size: B24/1 to B24/3 = 25.4mm; B24/4 to B24/6 = 31.75mm.Floor mounted, integral wall stays, 3⁄4" internal tappings. Suitable for any hot water system.*Using MYSON valves. **Approx outputs - NPD.
20628 spec pages:Layout 1 6/2/08 11:43 Page 7
outputs
outputs
outputs
KICKSPACE® Central Heatingunit unit unit grille grille watts watts Btu/hr Btu/hr watts watts Btu/hr Btu/hr
code width height depth height width Δ 60˚C Δ 60˚C Δ 60˚C Δ 60˚C Δ 50˚C Δ 50˚C Δ 50˚C Δ 50˚Cmm mm mm mm mm normal boost normal boost normal boost normal boost
Grille finishes: white, brown, black, brushed stainless steel, chrome, aluminium.Low voltage models have a transformer that reduces the power supply from 240 Volts to 12 Volts. Ideal for 'wet' area installations such as bathrooms. Connects to your central heating system. Fits in a plinth.For full details please refer to the Fan Convector technical guide.
KICKSPACE® Electricunit unit unit grille grille
code width height depth height width watts wattsmm mm mm mm mm normal boost
Grille finishes: white, brown, black, brushed stainless steel, chrome, aluminium. *Brown or white only. For full details please refer to the Fan Convector technical guide.
KICKSPACE® Duounit unit unit grille grille watts watts Btu/hr Btu/hr watts watts Btu/hr Btu/hr
code width height depth height width Δ 60˚C Δ 60˚C Δ 60˚C Δ 60˚C Δ 50˚C Δ 50˚C Δ 50˚C Δ 50˚Cmm mm mm mm mm normal boost normal boost normal boost normal boost
500Duo 321 93 321 101 496 1043 1340 3560 4572 835 1083 2849 3695Grille finishes: white, brown, black, brushed stainless steel, chrome, aluminium.NB: 500Duo model on electric mode gives a 1kW output. For full details please refer to the Fan Convector technical guide.
Sp
ecifica
tion
s6
3
outputs to EN442KIELDERwidth height width c/c tappings tappings pipe centres
code over flange over flange vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Projection: dependent upon wall stays. Wall to centre of tapping: dependent upon wall stays. Tube size: 31.75mm. Floor mounted, wall stays optional extra, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
outputs to EN442KASAItappings
code width height projection face to face Btu/hr wattsmm mm mm mm Δ 50˚C Δ 50˚C
Tube size: Frame = 31.75mm; cross tubes = 25.4mm. Sealed electric, code becomes EMR plus size.Wall fixed, 1⁄2" tappings. Painted units suitable for closed circuit applications only. Plated units suitable for any hot water system.Chrome outputs reduce by approximately 35%. Actuals available on request.
LOKOROwidth height wall to centre width c/c output/
code over flange over flange projection of connection vertical tubes ratedmm mm mm mm mm watts
Dual fuel factory fitted. Overall projection: dependent upon wall stays. Wall to centre of tapping: dependent upon wall stays.Tube size: S1/1 to S1/3 = 25.4mm; S1/4 to S1/6 = 31.75mm.Floor mounted, wall stays optional extra, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves. **Approx outputs - NPD.
Sp
ecifica
tion
s6
5
outputs to EN442MADRIGALcode width height projection tappings c/c Btu/hr watts
mm mm mm mm Δ 50˚C Δ 50˚CMAD1 500 1200 103-113 150 3050 894MAD2 600 1200 103-113 150 3661 1073MAD3 500 1800 103-113 150 4511 1322MAD4 600 1800 103-113 150 5411 1586
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Tube size: 31.75mm. Floor mounted, integral wall stays, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
outputs to EN442LUENAcode width height projection tappings c/c Btu/hr watts
mm mm mm mm Δ 50˚C Δ 50˚CNOC1 600 1220 86-98 50 904 265NOC2 600 1790 86-98 50 1723 505
Dual fuel factory fitted. Wall fixed 1⁄2" tappings to left side. Suitable for any hot water system.
20628 spec pages:Layout 1 6/2/08 11:43 Page 10
66
Sp
ecifica
tion
s
outputs to EN442MEDWAYcode width height projection tappings c/c Btu/hr watts
mm mm mm mm Δ 50˚C Δ 50˚CRTM1 500 760 86-98 468 850 249RTM2 500 1190 86-98 468 1375 403RTM3 500 1800 86-98 468 2085 611
Wall fixed 1⁄2" tappings facing down. Suitable for any hot water system.
outputs to EN442MERSEYwidth height tappings width c/c tappings floor to centre pipe centres radiator
code over valve overall projection wall to centre vertical tubes face to face of tapping for valves Btu/hr watts h x wmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C mm
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr watts h x wmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C mm
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Tube size: 31.75mm. Wall fixed, 3⁄4" external tappings. Suitable for any hot water system. *Using MYSON valves. **Approx output - NPD.
PECOS CR1code dimensions
inchCR1 48CR1 60CR1 72CR1 84
PECOS CR3code dimensions
inchCR3 24 DIACR3 30 DIA
All rails are:1" diameter brass tube providing elegance and strength.Optional fixed or adjustable ceiling stays available.Rails for quadrant and pentangle showers available.Special sizes available.
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr watts h x wmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C mm
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr watts h x wmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C mm
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Overall projection: dependent upon wall stays. Wall to centre of tapping: dependent upon wall stays. Tube size: 31.75mm. Floor mounted, wall stays optional extra, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
outputs to EN442TAYwidth height width c/c tappings tappings pipe centres
code over flange over flange vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm Δ 50˚C Δ 50˚C
Dual fuel factory fitted. Overall projection: dependent upon wall stays. Wall to centre of tapping: dependent upon wall stays.Tube size: B22/1 to B22/3 = 25.4mm; B22/4 to B22/6 = 31.75mm. Floor mounted, wall stays optional extra, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves. **Approx outputs - NPD.
20628 spec pages:Layout 1 6/2/08 11:44 Page 16
72
Sp
ecifica
tion
soutputs to EN442THIRLMERE
width height tappings width c/c tappings tappings pipe centres code over flange over flange projection wall to centre vertical tubes c/c floor to centre for valves Btu/hr watts
mm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚CB35/1 540 1302 140 58 457 457 N/A 457* 770 226**B35/2 693 1302 140 58 610 610 N/A 610* 900 264**B35/3 845 1302 140 58 762 762 N/A 762* 1035 303**
Dual fuel factory fitted. Tube size: 31.75mm .Wall fixed, 3⁄4" tappings facing down. Suitable for any hot water system.*Using MYSON valves. **Approx outputs - NPD.
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
code over flange over flange projection wall to centre vertical tubes face to face floor to centre for valves Btu/hr wattsmm mm mm mm mm mm mm mm Δ 50˚C Δ 50˚C
B49 693 1867 140 114 610 550 110 450* 1860 447Dual fuel factory fitted. Tube size: 31.75mmFloor mounted, integral wall stays, 3⁄4" internal tappings. Suitable for any hot water system. *Using MYSON valves.
outputs to EN442WINNEBEGOtappings wall width c/c tappings face tappings floor pipe centres
code width height projection to centre vertical tube to face to centre for valves Btu/hr watts radiatormm mm mm mm mm mm Δ 50˚C Δ 50˚C h x w