Top Banner
References: Wildanger, D. et al. “Solid Immersion Facilitates Fluorescence Microscopy with Nanometer Resolution and Sub-Ångström Emitter Localization“, Adv. Mater. 24, 309 (2012) Specs: 2-color 2D STED resolution < 30x30 nm (25x25 nm typical) 3D STED resolution < 100x100x100 nm, 80x80x90 nm typical (with easy 3D STED module) Change between objectives (water/ oil/ glycerol immersion) APD detection with highest detection sensitivity (>62% @ 680nm) Pulsed STED laser and time gating Combine with STED @595nm and RESOLFT for up to 6 superresolution channels Pulse / pixel / line / frame interleaved acquisition Abberior multicolor STED @ 775 nm Spectral properties and labels: 488 nm 594 nm 640 nm 775 nm Excitation wavelengths pulsed STED Recommended labels: Abberior STAR 520SXP, Abberior STAR 580, Abberior STAR 635P, Abberior STAR RED, ATTO 647N, ATTO 590, etc. Confocal STED RESCue mode optional Göttfert, F. et al. “Coaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution“, Biophysical J. 105, L01 (2013) Harke, B. et al. “Three-Dimensional Nanoscopy of Colloidal Crystals“, Nano Lett. 8, 1309 (2008) Berning, S. et al. “Nanoscopy in a Living Mouse Brain“, Science 335, 551 (2012) 561nm 520 nm Aberration corrections for 2D and 3D STED
1

Abberior multicolor STED @ 775 nm · References: Wildanger, D. et al. “Solid Immersion Facilitates Fluorescence Microscopy with Nanometer Resolution and Sub-Ångström Emitter Localization“,

Sep 07, 2019

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Abberior multicolor STED @ 775 nm · References: Wildanger, D. et al. “Solid Immersion Facilitates Fluorescence Microscopy with Nanometer Resolution and Sub-Ångström Emitter Localization“,

References:

Wildanger, D. et al. “Solid Immersion FacilitatesFluorescence Microscopy with NanometerResolution and Sub-Ångström EmitterLocalization“, Adv. Mater. 24, 309 (2012)

Specs:

2-color 2D STED resolution < 30x30 nm(25x25 nm typical)

3D STED resolution < 100x100x100 nm,80x80x90 nm typical (with easy 3D STEDmodule)

Change between objectives (water/ oil/ glycerol immersion)

APD detection with highest detection sensitivity(>62% @ 680nm)

Pulsed STED laser and time gating

Combine with STED @595nm and RESOLFTfor up to 6 superresolution channels

Pulse / pixel / line / frame interleaved acquisition

Abberior multicolor STED @ 775 nm

Spectral properties and labels:

488 nm 594 nm 640 nm 775 nm Excitation wavelengths pulsed STED

Recommended labels:

Abberior STAR 520SXP, Abberior STAR 580, Abberior STAR 635P, Abberior STAR RED, ATTO 647N, ATTO 590, etc.

Confocal STED

RESCue mode optional

Göttfert, F. et al. “Coaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution“, Biophysical J.105, L01 (2013)

Harke, B. et al. “Three-Dimensional Nanoscopyof Colloidal Crystals“, Nano Lett. 8, 1309(2008)

Berning, S. et al. “Nanoscopy in a LivingMouse Brain“, Science 335, 551 (2012)

561nm520 nm

Aberration corrections for 2D and 3D STED