Page 1: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Page 2: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 1

A5800_5820X-CMW520-R1211P04 Release Notes Keywords: version information, version changed, unresolved problems and avoidance measures, list of solved problems.

Abstract: This release notes describes the R1211P04 release with respect to hardware and software compatibility, released features and functions, software upgrading, and documentation.

Acronyms:

Acronym Full spelling IRF Intelligent Resilient Framework

AAA Authentication, Authorization and Accounting

ARP Address Resolution Protocol

CMW Comware

DHCP Dynamic Host Configuration Protocol

GVRP GARP VLAN Registration Protocol

IGMP Internet Group Management Protocol

LACP Link Aggregation Control Protocol

MIB Management Information Base

MSTP Multiple Spanning Tree Protocol

RIP Routing Information Protocol

MPLS Multi-protocol Label Switching

VPLS Virtual Private LAN Service

ISSU In-Service Software Upgrade

IRDP ICMP Router Discovery Protocol

NLB Network Load Balance

DCB Data Center Bridge

DCBX DCB Capability Exchange Protocol

COPP Control Panel Policy

Page 3: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 2

Contents

Version information ················································································································· 4 Version number ······················································································································· 4 Version history ·························································································································· 4 Hardware and software compatibility matrix ·············································································· 4 

Restrictions and cautions ········································································································· 6 

Feature list ····························································································································· 6 Hardware features ··················································································································· 6 

A5800 ······························································································································· 6 A5820X ··························································································································· 12 

Software features ··················································································································· 15 

Version updates ··················································································································· 27 Feature updates ···················································································································· 27 Command line updates·········································································································· 28 MIB updates ·························································································································· 28 Configuration changes ··········································································································· 29 

Configuration changes in R1211P04 ·················································································· 29 Configuration changes in R1211P02 ·················································································· 29 Configuration changes in R1211 ························································································ 29 

Open problems and workarounds ·························································································· 29 

List of resolved problems ········································································································ 30 Resolved problems in R1211P04 ······························································································· 30 Resolved problems in R1211P02 ······························································································· 32 Resolved problems in R1211 ···································································································· 34 

Related documentation ········································································································ 34 New feature documentation ·································································································· 34 Documentation set ················································································································ 34 Obtaining documentation ······································································································ 35 

Upgrading software ·············································································································· 35 Upgrading at the Boot menu ·································································································· 36 

Accessing the Boot menu ································································································ 36 XMODEM download through the console port ··································································· 38 TFTP download through an Ethernet port ··········································································· 48 FTP download through an Ethernet port ············································································· 50 

Upgrading at the CLI ·············································································································· 52 Copying files from a USB flash drive ··················································································· 52 FTP download from a server ······························································································ 53 TFTP download from a server ···························································································· 54 

Appendix ····························································································································· 54 Details of Changed CLI Commands in R1211P02 ······································································· 54 

ntp-service broadcast-server ···························································································· 54 ntp-service multicast-server ······························································································ 55 ntp-service unicast-peer ·································································································· 56 ntp-service unicast-server ································································································· 57 

Page 4: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 3

List of Tables

Table 1 Version history ······································································································· 4 

Table 2 Hardware and software compatibility matrix ···························································· 4 

Table 3 Models in the HP A5800 Switch Series ······································································· 6 

Table 4 HP A5800 Switch Series technical specifications ························································ 7 

Table 5 Pluggable component (except the OAP cards) compatibility matrix ························ 10 

Table 6 OAP card compatibility matrix ·············································································· 11 

Table 7 RPS compatibility matrix ······················································································· 12 

Table 8 Models in the HP A5820X Switch Series ··································································· 13 

Table 9 The HP A5820X Switch Series technical specifications ·············································· 13 

Table 10 Pluggable components (except the OAP cards) compatibility matrix ····················· 14 

Table 11 OAP card compatibility matrix ············································································ 15 

Table 12 RPS compatibility matrix ····················································································· 15 

Table 13 Software features of the A5800 series ··································································· 15 

Table 14 Software features of the A5820X series ································································· 22 

Table 15 Feature updates ································································································ 27 

Table 16 Command line updates ····················································································· 28 

Table 17 MIB updates ······································································································ 28 

Table 18 New feature documentation ·············································································· 34 

Table 19 Documentation set ···························································································· 34 

Table 20 Approaches to loading software on the switch ····················································· 35 

Table 21 Boot menu options ···························································································· 37 

Table 22 Description of the TFTP parameters ······································································ 49 

Table 23 Description of the FTP parameters ······································································· 51 

Page 5: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 4

Version information Version number

Comware software, Version 5.20, Release 1211P04

Note: You can see the version number with the command display version in any view. See Note ①.

Version history Table 1 Version history

Version number Last version Release Date Remarks A5800_5820X-CMW520-R1211P04

A5800_5820X-CMW520-R1211P02 2012-02-10 None

A5800_5820X-CMW520-R1211P02

A5800_5820X-CMW520-R1211 2011-08-02 None

A5800_5820X-CMW520-R1211 None 2011-05-04 None

Hardware and software compatibility matrix Table 2 Hardware and software compatibility matrix

Item Specifications Product family A5800/A5820X Series

Hardware platform

HP A5800-24G-PoE+ Switch HP A5800-24G Switch HP A5800-48G-PoE+ Switch with 2 Interface Slots HP A5800-24G-SFP Switch with 1 Interface Slot HP A5800-48G-PoE+ Switch with 1 Interface Slot HP A5800-48G Switch with 1 Interface Slot HP A5820X-14XG-SFP+ Switch with 2 Interface Slots HP A5820X-24XG-SFP+ Switch HP A5800AF-48G Switch HP A5820AF-24XG Switch HP A5800-24G-PoE+ TAA Switch HP A5800-24G TAA Switch HP A5800-48G-PoE+ TAA Switch with 2 Interface Slots HP A5800-24G-SFP TAA Switch with 1 Interface Slot

Page 6: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 5

Item Specifications HP A5800-48G-PoE+ TAA Switch with 1 Interface Slot HP A5800-48G TAA Switch with 1 Interface Slot HP A5820X-14XG-SFP+ TAA Switch with 2 Interface Slots HP A5820X-24XG-SFP+ TAA Switch

Minimum memory requirements 512 MB/1GB

Minimum Flash requirements 512 MB

Boot ROM version Version 215 or higher (Note: Perform the command display version command in any view to view the version information. See Note②)

Host software A5800_5820X-CMW520-R1211P04.bin

iMC version

iMC PLAT 5.0 SP1 (E0101L07) iMC UAM 5.0 SP1 (E0101P03) iMC EAD 5.0 SP1 (E0101P03) iMC NTA 5.0 SP1 (E0101L04) iMC UBA 5.0 SP1 (E0101L04) iMC QoSM 5.0 SP1 (E0101P01)

iNode version iNode PC 5.0 (E0103)

OAA version

Fiber Channel card: 9.0.6.15.0 IPS/AV card: ESS2110P10 Firewall card: R3166P12 High performance wireless AC card: R2107P10 Wireless AC Card: R3111P09

Sample: To display the host software and Boot ROM version of the A5800/A5820X, perform the following:

<HP> display version

HP Comware Platform Software

Comware Software, Version 5.20, Release 1211P04 ------- Note①

Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P.

HP A5800-48G Switch with 1 Interface Slot uptime is 0 week, 0 day, 0 hour, 4 min

utes

HP A5800-48G Switch with 1 Interface Slot with 2 Processors

1024M bytes SDRAM

4M bytes Nor Flash Memory

512M bytes Nand Flash Memory

Config Register points to Nand Flash

Hardware Version is Ver.B

CPLD Version is 003

BootRom Version is 215 ------ Note②

Page 7: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 6

[SubSlot 0] 48GE+4SFP Plus Hardware Version is Ver.B

[SubSlot 1] No Module

Restrictions and cautions None.

Feature list Hardware features A5800 Switch models and technical specifications

Table 3 lists the models in the HP A5800 Switch Series and their alias names used in this document. Table 4 describes the technical specifications.

Table 3 Models in the HP A5800 Switch Series

Product code HP description Alias

JC101A A5800-48G-PoE+ Switch with 2 Interface Slots A5800-48G-PoE+ (2 slots)

JG242A A5800-48G-PoE+ TAA Switch with 2 Interface Slots A5800-48G-PoE+ TAA (2 slots)

JC105A A5800-48G Switch with 1 Interface Slot A5800-48G (1 slot)

JG258A A5800-48G TAA Switch with 1 Interface Slot A5800-48G TAA (1 slot)

JC104A A5800-48G-PoE+ Switch with 1 Interface Slot A5800-48G-PoE+ (1 slot)

JG257A A5800-48G-PoE+ TAA Switch with 1 Interface Slot A5800-48G-PoE+ TAA (1 slot)

JC100A A5800-24G Switch A5800-24G

JG255A A5800-24G TAA Switch A5800-24G TAA

JC099A A5800-24G-PoE+ Switch A5800-24G-PoE+

JG254A A5800-24G-PoE+TAA Switch A5800-24G-PoE+TAA

JC103A A5800-24G-SFP Switch with 1 Interface Slot A5800-24G-SFP (1 slot)

JG256A A5800-24G-SFP TAA Switch with 1 Interface Slot A5800-24G-SFP TAA (1 slot)

JG225A A5800AF-48G Switch A5800AF-48G

Page 8: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 7

Table 4 HP A5800 Switch Series technical specifications

Item

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

Dimensions (H × W × D)

86.1 × 440 × 465 mm (3.39 × 17.32 × 18.31 in)

43.6 × 440 × 367 mm (1.72 × 17.32 × 14.45 in)

43.6 × 440 × 427 mm (1.72 × 17.32 × 16.81 in)

43.6 × 440 × 660 mm (1.72 × 17.32 × 25.98 in)

43.6 × 440 × 367 mm (1.72 × 17.32 × 14.45 in)

43.6 × 440 × 427 mm (1.72 × 17.32 × 16.81 in)

43.6 × 440 × 427 mm (1.72 × 17.32 × 16.81 in)

Weight ≤ 18 kg (39.68 lb)

≤ 6.5 kg (14.33 lb)

≤ 8.5 kg (18.74 lb)

≤ 12.2 kg (26.90 lb)

≤ 6.0 kg (13.23 lb)

≤ 8 kg (17.64 lb)

≤ 8.5 kg (18.74 lb)

Console ports

1, on the front panel

1, covered by the logo plate on the front panel

1, covered by the logo plate on the front panel

1, on the rear panel

1, on the front panel

1, on the front panel

1, covered by the logo plate on the front panel

Management Ethernet ports

N/A N/A N/A 1, on the rear panel

N/A N/A 1, on the rear panel

USB ports (full speed)

1, on the front panel

1, covered by the logo plate on the front panel

1, covered by the logo plate on the front panel

1, on the rear panel

1, on the front panel

1, on the front panel

1, covered by the logo plate on the front panel

10/100/1000Base-T Ethernet ports

48, PoE 48 48, PoE 48 24 24, PoE N/A

100/1000Base-X SFP ports

4 N/A N/A N/A N/A N/A 24

SFP+ ports N/A

4 4 6 4 4 4

You can plug an SFP+ transceiver module, SFP transceiver module or SFP+ cable into an SFP port. An SFP port plugged in with an SFP+ cable can be used to connect IRF devices.

Page 9: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 8

Item

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

Expansion interface card slots

2, on the front panel

1, on the rear panel

1, on the rear panel N/A

1, on the rear panel

1, on the rear panel

1, on the front panel

OAP card slots 1 N/A N/A N/A N/A N/A N/A

Fan tray slots

1, hot swapping

N/A Fixed fans are used.

N/A Fixed fans are used.

2, hot swapping

N/A Fixed fans are used.

N/A Fixed fans are used.

1, hot swapping

PoE module slots 1 N/A N/A N/A N/A N/A N/A

Power supply slots

2, hot swapping

N/A N/A 2, hot swapping

N/A N/A 2, hot swapping

AC-input voltage

Rated voltage: 100 VAC to 240 VAC, 50 or 60 Hz Max voltage: 90 VAC to 264 VAC, 47 or 63 Hz

DC-input voltage

Rated voltage: • 300

W at –48 VDC to –60 VDC

• 750 W at –54 VDC to –57 VDC

N/A N/A

Rated voltage: –40 VDC to –60 VDC

N/A N/A

Rated voltage: –48 VDC to –60 VDC

RPS DC-input voltage

Rated voltage: –52 VDC to –55 VDC

Rated voltage: 10.8 VDC to 13.2 VDC

Rated voltage: –52 VDC to –55 VDC

N/A

Rated voltage: 10.8 VDC to 13.2 VDC

Rated voltage: –52 VDC to –55 VDC

Rated voltage: –52 VDC to –55 VDC

Page 10: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 9

Item

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

Minimum power consumption

DC: 94 W AC: 96 W

102 W DC: 107 W AC: 131 W

105 W 67 W DC: 64 W AC: 85 W

DC: 58 W AC: 67 W

Maximum power consumption

Single DC output: 227 W Dual DC outputs: 237 W Single AC output: 714 W (425 W for PoE output) Dual AC outputs: 1147 W (740 W for PoE output)

163 W

DC: 973 W (740 W for PoE output) AC: 673 W (370 W for PoE output)

AC: 130 W DC: 130 W

105 W

DC: 870 W (740 W for PoE output) AC: 598 W (370 W for PoE output)

DC: 136 W AC: 146 W

Operating temperature

0°C to 45°C (32°F to 113°F)

Operating humidity 10% to 90%, non condensing

Hardware compatibility matrixes Interface cards, OAP cards, PoE modules, power supplies, and redundant power systems (RPSs) must be purchased separately. When you purchase or install these components, check that they are compatible with the switch.

You must separately purchase two fan trays for the A5800AF-48G switch. All other A5800 switches come with fixed fans or a fan tray installed.

Page 11: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 10

Table 5 Pluggable component (except the OAP cards) compatibility matrix

Card/module

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

Hot swappable power supply options

PSR300-12A (JC087A) Yes No No No No No No

PSR300-12D1 (JC090A) Yes No No No No No No

PSR750-A (JC089A) Yes No No No No No No

HP A5830/A5820/A5800 650W AC power supply (JC680A)

No No No Yes No No No

HP A5830/A5820/A5800 650W DC power supply (JC681A)

No No No Yes No No No

PSR150-A (JD362A) No No No No No No Yes

PSR150-D (JD366A) No No No No No No Yes

Hot swappable fan tray options

LSW1FAN (JC096A) Yes No No No No No No

LSWM1FANSC (JC682A) No No No Yes No No No

LSWM1FANSCB (JC683A) No No No Yes No No No

LSW1BFAN (JC098A) No No No No No No Yes

Interface card options

LSW1SP4P0 (JC091A) Yes Yes Yes No Yes Yes Yes

LSW1SP2P0 (JC092B) Yes Yes Yes No Yes Yes Yes

LSW1GP16P0 Yes Yes Yes No Yes Yes Yes

Page 12: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 11

Card/module

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

(JC095A)

LSW1GT16P (JC094A) Yes Yes Yes No Yes Yes Yes

Hot swappable PoE module options

LSW148POEM (JC097B)

Yes only for the A5800-48G-PoE+ (2 slots)

No No No No No No

LSW148POEM (JG260A)

Yes only for the A5800-48G-PoE+ TAA (2 slots)

No No No No No No

NOTE: The HP A5830/A5820/A5800 650W AC power supply and the HP A5830/A5820/A5800 650W DC power supply are referred to as the 650W AC power supply and the 650W DC power supply throughout this installation guide.

Table 6 OAP card compatibility matrix

Switch LSWM1FW10 (JD255A)

LSWM1WCM10 (JD441A)

LSWM1WCM10 (JG261A)

LSWM1WCM20 (JD443A)

LSWM1WCM20 (JG262A)

A5800-48G (1 slot) No No No Yes No

A5800-48G-PoE+ (1 slot) No No No Yes No

A5800-48G-PoE+ (2 slots) Yes Yes No Yes No

A5800AF- 48G No No No No No

A5800-24G No No No Yes No

A5800-24G-P No No No Yes No

Page 13: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 12

Switch LSWM1FW10 (JD255A)

LSWM1WCM10 (JD441A)

LSWM1WCM10 (JG261A)

LSWM1WCM20 (JD443A)

LSWM1WCM20 (JG262A)

oE+

A5800-24G-SFP (1 slot) No No No Yes No

A5800-48G-PoE+ TAA (1 slot)

No No No No Yes

A5800-48G-PoE+ TAA (2 slots)

No No Yes No Yes

A5800-48G TAA (1 slot) No No No No Yes

A5800-24G-PoE+ TAA No No No No Yes

A5800-24G-SFP TAA (1 slot)

No No No No Yes

A5800-24G TAA No No No No Yes

NOTE: You install the LSWM1WCM20 (JD443A, JG262A) card in the expansion interface card slot and all other OAP cards in the OAP card slot.

Table 7 RPS compatibility matrix

RPS

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800AF-48G

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A-RPS1600 (JG136A) Yes No Yes No No Yes Yes

A-RPS800 (JD183A) Yes Yes No No Yes No Yes

A5820X Switch models and technical specifications

Table 8 lists the models in the HP A5820X Switch Series and the alias that they are referred to in this document. Table 9 describes the technical specifications.

Page 14: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 13

Table 8 Models in the HP A5820X Switch Series

Product code HP description Alias

JG219A HP A5820AF-24XG Switch A5820AF-24XG

JC102A HP A5820X-24XG-SFP+ Switch A5820X-24XG-SFP+

JG243A HP A5820X-24XG-SFP+ TAA-compliant Switch A5820X-24XG-SFP+ TAA

JC106A HP A5820X-14XG-SFP+ Switch with 2 Interface Slots A5820X-14XG-SFP+ (2 slots)

JG259A HP A5820X-14XG-SFP+ TAA Switch with 2 Interface Slots A5820X-14XG-SFP+ TAA (2 slots)

Table 9 The HP A5820X Switch Series technical specifications

Item A5820AF-24XG A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

Dimensions (H × W × D) 43.6 × 440 × 660 mm (1.72 × 17.32 × 25.98 in)

43.6 × 440 × 427 mm (1.72 × 17.32 × 16.8 in)

86 × 440 × 467 mm (3.39 × 17.32 × 18.39 in)

Weight ≤ 11.2 kg (24.69 lb) ≤ 8.5 kg (18.74 lb) ≤ 17 kg (37.48 lb)

Console ports 1 1 1

Management Ethernet ports 1 1 N/A

USB ports 1 1 1

10/100/1000Base-T Ethernet ports 2 4 4

SFP+ ports 24 24 14

Expansion interface card slots N/A N/A 2, front panel

OAP card slots N/A N/A 1, rear panel

Fan tray slots 2, rear panel 1, rear panel 1, rear panel

Power supply slots 2, rear panel 2, rear panel 2, rear panel

AC-input voltage Rated voltage: 100 VAC to 240 VAC, 50 or 60 Hz Max voltage: 90 VAC to 264 VAC, 47 or 63 Hz

DC-input voltage

Rated voltage: –40 VDC to –60 VDC Max voltage: –40 VDC to –72 VDC

Rated voltage: –48 VDC to –60 VDC Max voltage: –40.5 VDC to –72 VDC

Rated voltage: –48 VDC to –60 VDC Max voltage: –40.5 VDC to –72 VDC

Minimum power consumption 135 W

AC: 128 W DC: 124 W

AC: 105 W DC: 103 W

Page 15: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 14

Item A5820AF-24XG A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

Maximum power consumption

AC: 205 W DC: 205 W

AC: 185 W DC: 176 W

AC: 245 W DC: 241 W

Operating temperature 0ºC to 45ºC (32°F to 113°F)

Operating humidity 10% to 90%, noncondensing

Hardware compatibility matrix Interface cards, OAP cards, power supplies, and RPSs must be purchased separately. When you purchase or install these components, check that they are compatible with the switch.

You must separately purchase two fan trays for the A5820AF-24XG switch. All other A5820X switches come with a fan tray installed.

Table 10 Pluggable components (except the OAP cards) compatibility matrix

Cards/modules A5820AF-24XG A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

Hot swappable power supply options HP A5830/A5820/A5800 650W AC power supply (JC680A) Yes No No

HP A5830/A5820/A5800 650W DC power supply (JC681A) Yes No No

PSR300-12A (JC087A) No Yes Yes

PSR300-12D1 (JC090A) No Yes Yes

Fan tray options

LSW1BFAN (JC098A) No Yes No

LSW1FAN (JC096A) No No Yes

LSWM1FANSC (JC682A) Yes No No

LSWM1FANSCB (JC683A) Yes No No

Interface card options

LSW1SP4P0 (JC091A) No No Yes

LSW1SP2P0 (JC092B) No No Yes

NOTE: The HP A5830/A5820/A5800 650W AC power supply and the HP A5830/A5820/A5800 650W DC power supply are referred to as the 650W AC power supply and the 650W DC power supply throughout this installation guide.

Page 16: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 15

Table 11 OAP card compatibility matrix

Switch LSWM1FW10 (JD255A)

LSWM1WCM10 (JD441A)

LSWM1WCM10 (JG261A)

LSWM1WCM20 (JD443A)

LSWM1WCM20 (JG262A)

A5820AF-24XG No No No No No

A5820X-24XG-SFP+ No No No No No

A5820X-24XG-SFP+ TAA No No No No No

A5820X-14XG-SFP+ (2 slots)

Yes Yes No Yes No

A5820X-14XG-SFP+ TAA (2 slots)

No No Yes No Yes

NOTE: You install the LSWM1WCM20 (JD443A or JG262A) card in the expansion interface card slot and all other OAP cards in the OAP card slot.

Table 12 RPS compatibility matrix

RPS A5820AF-24XG A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A-RPS800 (JD183A) No Yes Yes

A-RPS1600 (JG136A) No Yes Yes

Software features Table 13 Software features of the A5800 series

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

Switching capacity (full duplex)

284 Gbps 256 Gbps 208 Gbps 256

Gbps

Packet forwarding rate (whole system)

211.3 Mpps 190.5 Mpps 154.8 Mpps 190.5

Mpps

Page 17: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 16

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

Forwarding mode Store and forward

IRF

Ring topology Chain topology MAD for BFD/LACP/ARP ISSU

Link aggregation

Aggregation of GE ports Aggregation of 10 GE ports Static link aggregation Dynamic link aggregation An IRF fabric supports up to 128 aggregation groups, and each group supports up to eight GE ports or eight 10 GE ports. NLB

Flow control IEEE 802.3x flow control and back pressure

Jumbo frame With a maximum size of 10000 bytes

MAC address table

32K MAC addresses 1K static MAC addresses Blackhole MAC addresses Limit to the number of MAC addresses learned on a port

VLAN

Port-based VLANs (4094 VLANs) QinQ and selective QinQ Voice VLAN Protocol-based VLANs MAC-based VLANs IP subnet-based VLANs GVRP Super VLAN

VLAN mapping One-to-one VLAN mapping Many-to-one VLAN mapping Two-to-two VLAN mapping

ARP

16K entries 1K static entries Gratuitous ARP Standard proxy ARP and local proxy ARP ARP source suppression

Page 18: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 17

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

ARP detection (based on DHCP snooping entries/802.1X security entries/static IP-to-MAC bindings) Multicast ARP

ND 8K entries 1K static entries

VLAN virtual interface 1K

DHCP

DHCP client DHCP snooping DHCP relay agent DHCP server DHCPv6 client DHCPv6 snooping DHCPv6 relay agent DHCPv6 server

UDP helper Supported

DNS Dynamic domain name resolution Dynamic domain name resolution client IPv4/IPv6 addresses

IPv4 route

4K static routes RIP v1/2: up to 4K IPv4 routes OSPF v1/v2: up to 16K IPv4 routes BGP: up to 16K IPv4 routes ISIS: up to 16K IPv4 routes 256 equal-cost routes, each having 8 next hops at most Routing policy VRRP Policy based routing IRDP

IPv6 route

2K static routes RIPng: up to 2K IPv6 routes OSPF v3: up to 8K IPv6 routes BGP4+ for IPV6: up to 8K IPv6 routes ISIS for IPV6: up to 8K IPv6 routes

Page 19: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 18

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

256 equal-cost routes, each having 8 next hops Routing policy VRRP Policy routing

URPF Reverse route check strict mode and loose mode

MCE IPv4/IPv6

BFD

OSPF/OSPFv3 BGP/BGP4 IS-IS/IS-ISv6 PIM/IPM for IPv6 Static route MAD

Tunnel

IPv4 over IPv4 tunnel IPv4 over IPv6 tunnel IPv6 over IPv4 manual tunnel IPv6 over IPv4 6to4 tunnel IPv6 over IPv4 ISATAP tunnel IPv6 over IPv6 tunnel GRE tunnel

MPLS MPLS VPLS

IPv4 multicast

IGMP snooping v1/v2/v3 Multicast VLAN Multicast VLAN+ IGMP v1/v2/v3 PIM-DM PIM-SM PIM-SSM MSDP MBGP PIM BI-DIR Multicast VPN Multicast over MCE Mulitcast over MCE over tunnel

Page 20: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 19

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

IPv6 multicast

MLD snooping v1/v2 MLD v1/v2 PIM-DM/SM/SSM/BI-DIR for IPv6 IPv6 multicast VLAN IPv6 multicast VLAN+ MBGP for IPv6

Broadcast/multicast/unicast storm control

in port rate percentage in pps in bps

MSTP

STP/RSTP/MSTP STP root guard BPDU guard STP TC snooping

RRPP RRPP protocol Multi-instance RRPP

Smart Link Up to 26 groups Multi-instance Smart Link

Monitor link Supported

QoS/ACL

Restriction of the rates at which a port sends and receives packets, with a granularity of 8 kbps. Packet redirection CAR, with a granularity of 8 kbps. Global CAR (including aggregation CAR and hierarchical CAR) Eight output queues for each port Per-port and per-queue Queue scheduling algorithms, including SP, WDRR, WFQ, and SP + WDRR. 802.1p and DSCP re-mark Packet filtering at Layer 2 through Layer 4; flow classification based on source MAC address, destination MAC address, source IP (IPv4/IPv6) address, destination IP (IPv4/IPv6) address, port, protocol, and VLAN. Time range WRED Traffic shaping User profile COPP

Page 21: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 20

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

HQoS

Mirroring Traffic mirroring Port mirroring Multiple mirror observing ports

Remote mirroring Remote port mirroring (RSPAN/ERSPAN)

Security

Hierarchical management and password protection of users AAA authentication RADIUS authentication HWTACACS SSH 2.0 Port isolation Port security MAC address authentication IP-MAC-port binding IP source guard HTTPS SSL PKI Portal EAD Boot ROM access control (set Boot ROM password recovery)

OAA

IPS Firewall Anti virus Wireless access

802.1X

Up to 2,048 users Port-based and MAC address-based authentication Guest VLAN Trunk port authentication 802.1X-based dynamic QoS/ACL/VLAN assignment

Traffic Management

IPFIX (NetStream) sFlow

Software download and upgrade

XModem FTP

Page 22: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 21

Feature

A5800-48G-PoE+ (2 slots)/A5800-48G-PoE+ TAA (2 slots)

A5800-48G (1 slot)/A5800-48G TAA (1 slot)

A5800-48G-PoE+ (1 slot)/A5800-48G-PoE+ TAA (1 slot)

A5800-24G/A5800-24G TAA

A5800-24G-PoE+/A5800-24G-PoE+TAA

A5800-24G-SFP (1 slot)/A5800-24G-SFP TAA (1 slot)

A5800AF-48G

TFTP

Management

Configuration at the command line interface Remote configuration through Telnet Configuration through Console port SNMP RMON alarm, event and history recording IMC NMS Web-based network management System log Hierarchical alarms HGMPv2 NTP PoE Power supply alarm function Fan and temperature alarms BIMS zero configuration

Maintenance

Debug information output Ping and Tracert NQA Track Remote maintenance through Telnet Virtual cable test 802.1ag 802.3ah DLDP File download and upload through USB port Auto power down EEE

Page 23: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 22

Table 14 Software features of the A5820X series

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

Switching capacity (full duplex)

488 Gbps

Packet forwarding rate (whole system) 363 Mbps

Forwarding mode Store-forward and cut-through

IRF

Ring topology Chain Topology MAD of BFD/LACP/ARP ISSU

Link aggregation

Aggregation of GE ports Aggregation of 10-GE ports Static link aggregation Dynamic link aggregation An IRF fabric supports up to 128 aggregation groups, and each group supports up to eight GE ports or eight 10-GE ports NLB

Flow control IEEE 802.3x flow control and back pressure

Jumbo Frame Supports a maximum frame size of 10000 bytes

MAC address table

32K MAC addresses 1K static MAC addresses Blackhole MAC addresses Limit to the number of MAC addresses learned on a port

VLAN

Port-based VLANs (4094 VLANs) QinQ and selective QinQ Voice VLAN Protocol-based VLANs MAC-based VLANs IP subnet-based VLANs GVRP Super VLAN

VLAN mapping One-to-one VLAN mapping Many-to-one VLAN mapping Two-to-two VLAN mapping

ARP 8K entries 1K static entries Gratuitous ARP

Page 24: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 23

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

Standard proxy ARP and local proxy ARP ARP source suppression ARP detection (based on DHCP snooping entries/802.1x security entries/static IP-to-MAC bindings) Multicast ARP

ND 4K entries 1K static entries

VLAN virtual interface 1K

DHCP

DHCP client DHCP snooping DHCP relay agent DHCP server DHCPv6 client DHCPv6 snooping DHCPv6 relay agent DHCPv6 server

UDP Helper Supported

DNS Dynamic domain name resolution Dynamic domain name resolution client IPv4/IPv6 addresses

IPv4 route

4K static routes RIP v1/2: up to 4K IPv4 routes OSPF v1/v2: up to 12K IPv4 routes BGP: up to 12K IPv4 routes ISIS: up to 12K IPv4 routes 256 equal-cost routes, each having 8 next hops at most Routing policy VRRP Policy based routing IRDP

IPv6 route

2K static routes RIPng: up to 2K IPv6 routes OSPFv3: up to 6K IPv6 routes BGP4+: up to 6K IPv6 routes ISISv6: up to 6K IPv6 routes 256 equal-cost routes, each having 8 next hops at most Routing policy VRRP

Page 25: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 24

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

Policy based routing

URPF Strict mode and loose mode

MCE IPv4/IPv6

BFD

OSPF/OSPFv3 BGP/BGP4 IS-IS/IS-ISv6 PIM/IPM for IPv6 Static route MAD

Tunnel

IPv4 over IPv4 tunnel IPv4 over IPv6 tunnel IPv6 over IPv4 manual tunnel IPv6 over IPv4 6to4 tunnel IPv6 over IPv4 ISATAP Tunnel IPv6 over IPv6 tunnel GRE tunnel

IPv4 multicast

IGMP snooping v1/v2/v3 Multicast VLAN Multicast VLAN+ IGMP v1/v2/v3 PIM-DM PIM-SM PIM-SSM MSDP MBGP PIM BI-DIR Multicast over MCE Mulitcast over MCE over Tunnel

IPv6 multicast

MLD snooping v1/v2 MLD v1/v2 PIM-DM/SM/SSM/BI-DIR for IPv6 IPv6 multicast VLAN IPv6 multicast VLAN+ MBGP for Ipv6

Broadcast/multicast/unicast storm control

In port rate percentage In pps In bps

MSTP STP/RSTP/MSTP

Page 26: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 25

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

STP root guard BPDU guard STP TC snooping

RRPP RRPP protocol Multi-instance RRPP

Smart link Up to 26 groups Multi-instance Smart Link

Monitor link Supported

QoS/ACL

Restriction of the rates at which a port sends and receives packets, with a granularity of 8 kbps. Packet redirection CAR, with a granularity of 8 kbps. Global CAR (including aggregation CAR and hierarchical CAR) Eight output queues for each port Per-port and per-queue queue scheduling algorithms, including SP, WDRR, WFQ, and SP + WDRR 802.1p and DSCP re-mark Packet filtering at Layer 2 through Layer 4; flow classification based on source MAC address, destination MAC address, source IPv4/IPv6 address, destination IPv4/IPv6 address, port, protocol, and VLAN. Time range WRED Traffic shaping User profile COPP

Mirroring Traffic mirroring Port mirroring Multiple mirror observing ports

Remote mirroring Remote port mirroring (RSPAN/ERSPAN)

Security

Hierarchical management and password protection of users AAA authentication RADIUS authentication HWTACACS SSH 2.0 Port isolation Port security MAC address authentication IP-MAC-port binding IP source guard

Page 27: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 26

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

HTTPS SSL PKI Portal EAD Boot ROM access control (Set Boot ROM password recovery)

Data Center Feature PFC DCBX

OAA

IPS Firewall Anti virus Wireless access FC

802.1X

Up to 2,048 users Port-based and MAC address–based authentication Guest VLAN Trunk port authentication 802.1X-based dynamic QoS/ACL/VLAN assignment

Software download and upgrade

XModem FTP TFTP

Management

Configuration at the command line interface Remote configuration through Telnet Configuration through Console port SNMP RMON alarm, event and history recording IMC NMS Web-based network management System log Hierarchical alarms HGMPv2 NTP Power supply alarm function Fan and temperature alarms BIMS zero configuration

Maintenance Debug information output Ping and Tracert NQA

Page 28: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 27

Feature A5820X-14XG-SFP+ (2 slots)/A5820X-14XG-SFP+ TAA (2 slots)

A5820X-24XG-SFP+/A5820X-24XG-SFP+ TAA

A5820AF-24XG

Track Remote maintenance through Telnet Virtual cable test 802.1ag 802.3ah DLDP File download and upload through USB port Auto power down EEE

Version updates Feature updates

Table 15 Feature updates

Item Description

A5800_5820X-CMW520-R1211P04

Hardware feature updates

New features: None Deleted features: None

Software feature updates

New features: None Deleted features: None Modified features: None

A5800_5820X-CMW520-R1211P02

Hardware feature updates

New features: None Deleted features: None

Software feature updates

New features: 1. Support NTP Version 4. Deleted features: None Modified features: None

A5800_5820X-CMW520-R1211

Hardware feature updates

New features: None Deleted features: None

Software feature updates

New features: None Deleted features: None Modified features: None

Page 29: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 28

Command line updates Table 16 Command line updates

Item Description

A5800_5820X-CMW520-R1211P04

New commands None

Removed commands None

Modified commands None

A5800_5820X-CMW520-R1211P02

New commands None

Removed commands None

Modified commands

1. ntp-service unicast-server 2.ntp-service unicast-peer 3.ntp-service broadcast-server 4.ntp-service multicast-server Version parameter changed: the ranges from 1 to 3 in previous version and the ranges from 1 to 4 in R1211P02 Refer to Details of Changed CLI Commands in R1211P02

A5800_5820X-CMW520-R1211

New commands None

Removed commands None

Modified commands None

MIB updates Table 17 MIB updates

Item MIB file Module Description

A5800_5820X-CMW520-R1211P04

New

hh3c-if-ext.mib HH3C-IF-EXT-MIB Added hh3cIfIsPoe

hh3c-ntp.mib HH3C-NTP-MIB Added hh3cNTPSysPollSec

Added hh3cNTPSysClockSec Added hh3cNTPServerIP

Modified None None None

Page 30: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 29

Item MIB file Module Description

A5800_5820X-CMW520-R1211P02 New None None None

Modified None None None

A5800_5820X-CMW520-R1211 New None None None

Modified None None None

Configuration changes Configuration changes in R1211P04

None

Configuration changes in R1211P02 None

Configuration changes in R1211 None

Open problems and workarounds LSD50925

• First found-in version: A5800_5820X-CMW520-R1211 • Description: Issue the display interface MTunnel command. The displayed “maximum

transmit unit” is 1460 which is different from the actual value. • Workaround: None.

LSD60159 • First found-in version: A5800_5820X-CMW520-R1211 • Description: Configure a hybrid port to remove the VLAN tag of traffic from VLANs

other than VLAN 1. Use IMC to view the port list of the configured VLANs. The hybrid port is not displayed.

• Workaround: None.

LSD50222 • First found-in version: A5800_5820X-CMW520-R1211 • Description: Use an IRF fabric as a PE. The local CE can communicate with the remote

CE over a CCC connection through the master device but not a slave device.

Page 31: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 30

• Workaround: Connect the CE to the master device.

List of resolved problems Resolved problems in R1211P04 LSD65853

• First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Configuring a very long password for web account used by cluster. • Description: Exception occurs and device reboots.

ZDD04769 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: The device acts as the source DR and the downstream device

enable/disable PIM-SM continuously. • Description: Exception occurs and device reboots.

ZDD04754 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: The device runs as a DHCP server and there are a lot of client with

conflictive addresses. • Description: The CPU usage ratio will become high for a long time.

ZDD04724 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: LDP session is kept in a vibration state by an unstable interface. • Description: Exception occurs and device reboots.

LSD64220 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Deploy sFlow in the device. • Description: The port information in sFlow packet is 32 bit, it should be 64 bit.

LSD65092 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Get or set RPINGMib to operate NQA through SNMP. • Description: Result in DISMAN-PING-MIB::pingResultsOperStatus fails and cannot be

restored, the device reboots occasionally.

ZDD04358 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Build Martini MPLS L2VPN with CISCO'S device, and configure master and

backup PW, when PW switchover happens on CISCO'S device.

Page 32: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 31

• Description: LDP session shaking.

LSD65472 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Device receives HTTP packets, which may be sent by some test software,

such as Avalanche. • Description: Memory will leak.

LSD64598 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Enable debugging switch for VTY, execute the free user vty command. • Description: Exception occurs.

LSD66815 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: On the A5820X Series, apply more than 25 ACL rules based on port range. • Description: Starting from 25th rule, the ACL function is not correct.

LSD66490 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Enable loopback-detection function and set loopback-detection action. • Description: After some specific configuration, the log of loopback-detection action is

different from the value configured.

LSD65841 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Enable Link-aggregation LACP traffic-redirect-notification, all traffic flow on

the master device of the IRF, reboots master, device rejoin the IRF. • Description: L2 forwarding was interrupted about 1ms.

LSD68572 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Upgrade software from R1110P05/R1211 toR1211P02. • Description: Special sub-card LSWM1WCM10 changes to LSWM1FW10.

LSD65758 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Insert old 3Com SFP transceivers. • Description: There is some checksum error information.

LSD65746 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: Configure switch IRF member ID to 10, set up BFD connection, then

shutdown the ports which BFD session running. • Description: BFD session is still up and cannot restore normally.

Page 33: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 32

HWD35697 • First found-in version: A5800_5820X-CMW520-R1211P02 • Condition: When the switch of HP TAA power up, insert the POE sub-card without

firmware. • Description: POE function fails.

LSD68690 • First found-in version: A5800_5820X-CMW520-R1206 • Condition: If there is some signal noise on the input clock of 10GE port, which may be

caused by voltage DIP. • Description: The 10GE port's link status is not stable occasionally.

LSD67497 • First found-in version: A5800_5820X-CMW520-R1206 • Condition: Multicast VPN is enabled in the following network. For network Private 1,

Dev A is a PE device. For network Private 2 and Dev B, Dev A is a P device. Dev A can receive private PIM RP and NBR information from uplink device.

• Description: Dev A doesn’t pass private PIM RP/NBR information to downlink PE Dev B,

which causes the downlink PE not able to see PIM RP and NBR information within the VPN.

Resolved problems in R1211P02 LSD63054

• First found-in version: A5800_5820X-CMW520-R1211 • Condition: The switch sends a sFlow packet that have a "sampled_header" structure

for a sampled packet. • Description: The sFlow packet also includes the sampled_ipv4 and sampled_ethernet

structures for the same packet.

LSD63203 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: In two-to-two VLAN mapping. • Description: The remark service-vlan-id command fails to take effect in the inbound

direction of the customer-side port.

Page 34: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 33

ZDD04235 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: repeatly BGP routing shaking under a large number of routing table at a

long time. • Description: device reboots.

LSD61915 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Start up device with AC card (LSWM1WCM20) inserted. • Description: The ports of AC card (LSWM1WCM20) are not UP.

LSD62780 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Using NLB Feature in MCE application. • Description: the packet cannot be forwarded correctly.

LSD62622 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Using SNMP to get sFlow sampler of specific interface. • Description: Get Fail.

LSD62416 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: deploy auto-config on device, and the configuration file contains “save

force” command. • Description: the “save force” command does not take effect.

LSD59864 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: Using BIMS to manage irf device. • Description: The BIMS system shows multi-device in the management user interface.

ZDD04271 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: In specific network, the device created a large number of abnormal LSP

and LDP LSP resource will be exhausted by these LSP. So the normal LDP LSP does not measure up.

• Description: The normal LSP cannot setup.

ZDD04176 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: there is ARP attack, and the source MAC address is fixed, but the sender ip

in ARP packet does not hold the same network address with incoming vlan interface. • Description: the anti-ARP attack function does not take effect.

Page 35: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 34

ZDD04163 • First found-in version: A5800_5820X-CMW520-R1211 • Condition: the device is connected with a specific IP Phone and executed the

“display lldp” command. • Description: there is illegal character in the output of chasis field.

Resolved problems in R1211 First release

Related documentation New feature documentation

Table 18 New feature documentation

Feature Document title None None

For information about other features, see Documentation set.

Documentation set Table 19 Documentation set

Document title Version HP A5820 Switch Series Installation Guide 5W100

HP A5800 Switch Series Installation Guide 5W100

HP A5820 & A5800 Switch Series Command References 5W100

HP A5820 & A5800 Switch Series Configuration Guides 5W100

HP PSR150-A & PSR150-D Power Supplies User Guide 5PW100

HP PSR300-12A & PSR300-12D1 Power Supplies User Guide 5PW100

HP A5830/A5820/A5800 650W AC (JC680A) & 650W DC (JC681A) Power Supplies User Guide 5PW100

HP PSR750-A Power Supply User Guide 5PW100

HP LSW1FAN & LSW1BFAN Fan Assembly Installation 5W100

Page 36: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 35

Document title Version HP LSWM1FANSC & LSWM1FANSCB Fan Assembly Installation 5W100

HP OAP Cards User Guide 5PW100

HP LSW148POEM PoE Module User Guide 5PW100

HP A5820 & A5800 Switch Series Interface Cards User Guide 5PW100

Hot Swappable Power Supply Ordering Guide for HP A5800-48G-PoE+ Switch with 2 Interface Slots

6W100

Obtaining documentation For the latest documentation, visit the HP website, www.hp.com, and select the Support & Drivers. • Select Product Support & Troubleshooting. • Enter product name/number OR select the automatic product name/number

detection OR select a product category. • From the product page, choose Manuals to see the documentation associated with

your product.

Upgrading software You can access the Boot menu or CLI to download system software and Boot ROM images to Flash memory by using XMODEM, TFTP, or FTP.

Table 20 Approaches to loading software on the switch

Approach Section

Upgrading at the Boot menu

XMODEM download through the console port

TFTP download through an Ethernet port

FTP download through an Ethernet port

Upgrading at the CLI

Copying files from a USB flash drive

FTP download from a server

TFTP download from a server

The system software and Boot ROM images for the HP A5800 and A5820X Switch Series are packaged in a .bin file. You can download this file to upgrade both Boot ROM and system software, or upgrade only Boot ROM.

The Boot ROM image in the .bin package file comprises a basic section and an extended section. The basic section is the minimum boot image. The extended section enables the Boot ROM to bootstrap the system and upgrade system software.

Page 37: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 36

IMPORTANT: When upgrading Boot ROM, upgrade both sections to ensure the functionality of the entire system.

NOTE: • For the A5800-24G-SFP (1 slot), A5800-24G-SFP TAA (1 slot), A5800AF-48G,

A5820AF-24XG, A5820X-24XG-SFP+, and A5820X-24XG-SFP+ TAA switches, HP recommends that you use the management Ethernet port to download image files. Thisport can work even if all network ports have failed.

• You download files through the management Ethernet port in the same way as througha common Ethernet network port. This document uses a common Ethernet network portas an example.

Upgrading at the Boot menu Accessing the Boot menu

Power on the switch (for example, an HP A5800AF-48G switch), and you can see the following information: Starting......

********************************************************************************

* *

* HP A5800AF-48G Switch BOOTROM, Version 212 *

* *

********************************************************************************

Copyright (c) 2010-2011 Hewlett-Packard Development Company, L.P.

Creation Date : Feb 23 2011,15:47:03

CPU Clock Speed : 750MHz

Memory Size : 1024MB

Flash Size : 512MB

CPLD Version : 005

PCB Version : Ver.A

Mac Address : 00E058778800

Press Ctrl-B to enter Extended Boot menu...0

When “Press Ctrl-B to enter Extended Boot menu” appears, press Ctrl + B within five seconds. Please input BootRom password:

Page 38: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 37

NOTE: • The system by default starts up in normal (full) mode, and you must press Ctrl + B within

five seconds to enter the Boot menu. In fast startup mode, you must press Ctrl + B withinone second to enter the Boot menu.

• If you fail to press Ctrl + B within the time limit, the system starts decompressing files, andyou must restart the switch to access the Boot menu.

At the prompt, enter the Boot ROM password (no password is required by default) to access the Boot menu: BOOT MENU

1. Download application file to flash

2. Select application file to boot

3. Display all files in flash

4. Delete file from flash

5. Modify BootRom password

6. Enter BootRom upgrade menu

7. Skip current system configuration

8. Set BootRom password recovery

9. Set switch startup mode

0. Reboot

Enter your choice(0-9):

Table 21 Boot menu options

Item Description

1. Download application file to flash

Download a .bin software package file to Flash memory. You can choose this option to upgrade both system software and Boot ROM.

2. Select application file to boot Select the software package file to boot.

3. Display all files in flash Display all files in Flash memory.

4. Delete file from flash Delete files from Flash memory.

5. Modify BootRom password Modify the Boot ROM password.

6. Enter BootRom upgrade menu Access the Boot ROM update menu. You can choose this option to separately upgrade Boot ROM.

7. Skip current system configuration

Start the switch with the default empty configuration. This is a one-time operation and does not take effect at the next reboot. You use this option when you forget the console login password.

8. Set BootRom password recovery Disable or enable the Boot ROM password recovery function. By default, Boot ROM recovery is enabled. You can disable this function to protect system security.

9. Set switch startup mode Set the switch in normal (full) or fast startup mode. The system by default starts up in normal (full) mode, and you must press Ctrl + B within five seconds to enter the Boot

Page 39: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 38

Item Description menu. In fast startup mode, you must press Ctrl + B within one second to enter the Boot menu.

0. Reboot Restart the switch.

NOTE: The procedure of upgrading Boot ROM is the same as upgrading system software. This guide takes upgrading Boot ROM as an example.

XMODEM download through the console port You can connect a PC or terminal to the console port to download files to the switch by using XMODEM. XMODEM supports 128-byte data packets and provides the reliability mechanisms including checksum, CRC, and retransmissions (up to 10).

Setting terminal parameters Run a terminal emulator program on the console terminal, for example, a PC.

The following are the required terminal settings: • Bits per second—9,600 • Data bits—8 • Parity—None • Stop bits—1 • Flow control—None • Emulation—VT100

Follow these steps to set terminal parameters, for example, on a Windows XP HyperTerminal:

Step1 Select Start > All Programs > Accessories > Communications > HyperTerminal, and in the Connection Description dialog box that appears, type the name of the new connection in the Name text box and click OK.

Page 40: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 39

Figure 1 Connection description of the HyperTerminal

Step2 Select the serial port to be used from the Connect using drop-down list, and click OK.

Figure 2 Set the serial port used by the HyperTerminal connection

Step3 Set Bits per second to 9600, Data bits to 8, Parity to None, Stop bits to 1, and Flow control to None, and click OK.

Page 41: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 40

Figure 3 Set the serial port parameters

Step4 Select File > Properties in the HyperTerminal window.

Page 42: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 41

Figure 4 HyperTerminal window

Step5 Click the Settings tab, set the emulation to VT100, and click OK in the Switch Properties dialog box.

Page 43: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 42

Figure 5 Set terminal emulation in Switch Properties dialog box

Upgrading Boot ROM Perform the following tasks to upgrade Boot ROM by using XMODEM through the console port: 1. Access the Boot menu, and enter 6 or press Ctrl + U to enter the Boot ROM update

menu: 1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

IMPORTANT: Always select option 1 to upgrade the entire Boot ROM. You can use option 2 or option 3 only under the guidance of an HP engineer.

2. Enter 1 at the Boot ROM update menu to set the protocol parameters. 1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

Page 44: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 43

0. Return to boot menu

Enter your choice(0-3):

3. Enter 3 to set the XMODEM download baud rate. Please select your download baudrate:

1.* 9600

2. 19200

3. 38400

4. 57600

5. 115200

0. Return

Enter your choice (0-5):

4. Select an appropriate download rate, for example, enter 5 to select 115200 bps. Download baudrate is 115200 bps

Please change the terminal's baudrate to 115200 bps and select XMODEM protocol

Press enter key when ready

NOTE: Typically the size of a .bin file is over 10 MB. Even at a baud rate of 115200 bps, the download takes tens of minutes.

5. Set the serial port on the terminal to use the same baud rate and protocol as the console port. If you select 9600 bps as the download rate for the console port, skip this task.

Step1 Select Call > Disconnect in the HyperTerminal window to disconnect the terminal from the switch.

Figure 6 Disconnect the terminal from the switch

Step2 Select File > Properties. In the Properties dialog box, click Configure (see Figure 7 ), and then select 115200 from the Bits per second drop-down list box (see Figure 8 ).

Page 45: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 44

Figure 7 Properties dialog box

Page 46: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 45

Figure 8 Modify the baud rate

Step3 Select Call > Call to reestablish the connection.

Figure 9 Reestablish the connection

NOTE: The new settings can take effect only after you reestablish the connection.

6. Upload the software package file from the terminal to the switch.

Step1 After establishing a connection between the terminal and the switch, press Enter in the HyperTerminal window. Now please start transfer file with XMODEM protocol.

If you want to exit, Press <Ctrl+X>.

Loading ...CCCCCCCCCC

Step2 Select Transfer > Send File in the HyperTerminal window (see Figure 10 ), and click Browse in the pop-up dialog box (see Figure 11 ) to select the source file (for example, update.bin), and select Xmodem from the Protocol drop-down list.

Page 47: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 46

Figure 10 Transfer menu

Figure 11 File transmission dialog box

Step3 Click Send. The following dialog box appears:

Figure 12 Send the application file using XMODEM

7. Upgrade Boot ROM on the switch.

When the terminal displays the following prompt, enter Y to update the basic Boot ROM section: Loading ...CCCC Done!

Page 48: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 47

Will you Update Basic BootRom? (Y/N):Y

When the terminal displays the following prompt, enter Y to update the extended Boot ROM section: Updating Basic BootRom...........Done!

Updating extended BootRom? (Y/N):Y

When the Boot ROM upgrade is completed, the terminal displays the following information: Updating extended BootRom.........Done!

Please change the terminal's baudrate to 9600 bps, press ENTER when ready.

8. If you are using a download rate other than 9600 bps, restore the baud rate of the serial port on the terminal to 9600 bps. If the baud rate is 9600 bps, skip this step.

9. Press any key to return to the Boot ROM update menu and enter 0. On the Boot menu that appears, enter 0 to restart the switch so the updated image can take effect. The following is the Boot ROM update menu:

1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

Upgrading system software To upgrade system software, enter 1 at the Boot menu, and the following menu appears: 1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):3

Enter 3 to set the XMODEM parameters for downloading the software package file.

The subsequent procedure is the same as loading Boot ROM images, except that you must set the attribute of the file as main, backup, or none to complete the file loading. Writing flash..................................................................

................Done!

Please input the file attribute (Main/Backup/None) M

Done!

NOTE: • The switch always attempts to boot first with the main file, and if the attempt fails for

example, because the main file is not available, the switch tries to boot with the backup file. A file with the none attribute is just stored in Flash memory for backup and you must change its attribute to make it usable at reboot.

• If a file with the same attribute as the file you are loading is already in the Flash memory,the attribute of the old file changes to none after the new file becomes valid.

• The switch automatically updates Boot ROM when loading system software.

Page 49: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 48

TFTP download through an Ethernet port The switch can work as a TFTP client to download files from a TFTP server.

Upgrading Boot ROM 1. Connect an Ethernet port (for example, GigabitEthernet 1/0/25) of the switch to the

server and connect the console port of the switch to a PC (see Figure 13 ).

Figure 13 Load software using TFTP/FTP through Ethernet port

NOTE: • The PC and the TFTP/FTP server can be co-located. • The A5800 and A5820X switches do not come with any TFTP server program, and you

must install one yourself.

2. Run the TFTP server program on the server and specify the source file path. 3. Run a terminal emulator program on the PC, power on the switch, access the Boot

menu, and enter 6 to access the following Boot ROM update menu: 1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

4. Enter 1 to upgrade the entire Boot ROM and access the following protocol parameter setting menu:

Bootrom update menu:

1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):

5. Enter 1 to set the TFTP parameters. Load File Name :update.bin

Server IP Address :10.10.10.2

Local IP Address :10.10.10.3

Gateway IP Address :

Page 50: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 49

Table 22 Description of the TFTP parameters

Item Description Load File Name : Name of the file to be downloaded (for example, update.bin)

Server IP Address : IP address of the TFTP server (for example, 10.10.10.2)

Local IP Address : IP address of the switch (for example, 10.10.10.3)

Gateway IP Address : IP address of the gateway (in this example, no gateway is required because the server and the switch are on the same subnet)

NOTE: If the switch and the server are on different subnets, you must specify a gateway address for the switch.

6. Enter all required parameters. Loading........................................................................

...............................................................................

................................Done!

Will you Update Basic BootRom? (Y/N):Y

Enter Y at the prompt to upgrade the basic Boot ROM section. Updating Basic BootRom...........Done!

Updating extended BootRom? (Y/N):Y

Enter Y at the prompt to upgrade the extended Boot ROM section.

When the upgrade is completed, the following information appears: Updating extended BootRom.........Done!

7. Press any key to return to the Boot ROM update menu, enter 0 to return to the Boot menu, and enter 0 to restart the switch from the Boot menu so the upgraded Boot ROM can take effect.

Press enter key when ready

1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

Upgrading system software To upgrade switch software, enter 1 at the Boot menu to access the following menu: 1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):3

Enter 1 to set the TFTP parameters.

The subsequent procedure of is the same as upgrading Boot ROM, except that you must set the attribute of the file as main, backup, or none to complete the file loading.

Page 51: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 50

Writing flash..................................................................

................Done!

Please input the file attribute (Main/Backup/None) M

Done!

NOTE: • If a file with the same attribute as the file you are loading is already in the Flash memory,

the attribute of the old file changes to none after the new file becomes valid. • The switch automatically updates Boot ROM when loading system software.

FTP download through an Ethernet port The switch can work as an FTP server or FTP client to download files through an Ethernet port. This section uses the switch as an FTP client to describe the procedure.

Upgrading Boot ROM

NOTE: When upgrading Boot ROM, the switch can work only as an FTP client.

1. Connect an Ethernet port (GigabitEthernet 1/0/25, for example) of the switch to the server and connect the console port of the switch to a PC (see Figure 13 ).

2. Run an FTP server program on the server, configure an FTP username and password, and specify the source file path.

3. Run a terminal emulator program on the PC, power on the switch, access the Boot menu, and enter 6 to access the following Boot ROM update menu:

1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

4. Enter 1 to upgrade the entire Boot ROM and access the following protocol parameter setting menu:

Bootrom update menu:

1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):

5. Enter 2 to set the FTP parameters. Load File Name :update.bin

Server IP Address :10.10.10.2

Local IP Address :10.10.10.3

Gateway IP Address :0.0.0.0

Page 52: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 51

FTP User Name :5800

FTP User Password :123

Table 23 Description of the FTP parameters

Item Description Load File Name : Name of the file to be downloaded (for example, update.bin)

Server IP Address : IP address of the FTP server (for example, 10.10.10.2)

Local IP Address : IP address of the switch (for example, 10.10.10.3)

Gateway IP Address : IP address of the gateway (in this example, no gateway is required because the server and the switch are on the same subnet)

FTP User Name Username for accessing the FTP server, which must be the same as configured on the FTP server.

FTP User Password Password for accessing the FTP server, which must be the same as configured on the FTP server.

NOTE: If the switch and the server are on different subnets, you must specify a gateway address for the switch.

6. Enter all required parameters. Will you Update Basic BootRom? (Y/N):Y

Enter Y at the prompt to upgrade the basic Boot ROM section. Updating Basic BootRom...........Done!

Updating extended BootRom? (Y/N):Y

Enter Y at the prompt to upgrade the extended Boot ROM section.

When the upgrade is completed, the following information appears: Updating extended BootRom.........Done!

7. Press any key to return to the Boot ROM update menu, enter 0 to return to the Boot menu, and enter 0 to restart the switch from the Boot menu so the upgraded Boot ROM can take effect.

Press enter key when ready

1. Update full BootRom

2. Update extended BootRom

3. Update basic BootRom

0. Return to boot menu

Enter your choice(0-3):

Upgrading system software To upgrade switch software, enter 1 in the Boot menu to access the following menu: 1. Set TFTP protocol parameter

2. Set FTP protocol parameter

3. Set XMODEM protocol parameter

0. Return to boot menu

Enter your choice(0-3):3

Page 53: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 52

Enter 2 to set the FTP parameters.

The subsequent procedure is the same as upgrading Boot ROM, except that you must set the attribute of the file as main, backup, or none to complete the file loading. Writing flash..................................................................

................Done!

Please input the file attribute (Main/Backup/None) M

Done!

NOTE: • If a file with the same attribute as the file you are loading is already in the Flash memory,

the attribute of the old file changes to none after the new file becomes valid. • The switch automatically updates Boot ROM when loading system software.

Upgrading at the CLI You can remotely download Boot ROM and system software images at the CLI.

Copying files from a USB flash drive Every A5800 or A5820X switch has a USB port on its front panel so you can copy software package files from a USB flash drive.

Follow these steps to copy a software package file from a USB flash drive and upgrade Boot ROM and system software:

Step1 Plug the USB flash drive in the USB port of the switch.

Step2 Copy the software package file (for example, update.bin) to the Flash memory of the switch. <HP> cd flash:

<HP> copy usba:/update.bin update.bin

Step3 Remove the USB flash drive, and load the Boot ROM image. <HP> bootrom update file update.bin slot 1

This command will update bootrom file on the specified board(s), Continue? [Y/

N]:y

Now updating bootrom, please wait...

Step4 Load the system software image and specify the file as the main file at the next reboot. <HP> boot-loader file update.bin slot 1 main

This command will set the boot file of the specified board. Continue? [Y/N]:y

The specified file will be used as the main boot file at the next reboot on slot 1!

<HP> display boot-loader

Slot 1

The current boot app is: flash:/update.bin

The main boot app is: flash:/update.bin

The backup boot app is: flash:/update.bin

<HP> reboot

Page 54: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 53

NOTE: • You must reboot the switch with the reboot command to complete the upgrade.

Before that, save the configurations you have made to avoid data loss. • If Flash memory is insufficient, load the Boot ROM image first and delete useless files to

free up Flash memory before you load the system software image. • Avoid power failure during the loading process.

FTP download from a server This section uses the topology in Figure 14 as an example. Run FTP server on the management PC at 202.10.10.53, create an FTP username admin and password, specify the source file path, telnet to the switch, and get the software package file (for example, update.bin) from the server.

Figure 14 FTP download from a server

Step1 Get the file to the switch by using FTP. <HP> ftp 202.10.10.53

Trying ...

Press CTRL+K to abort

Connected.

220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user

User(none):admin

331 Give me your password, please

Password:

230 Logged in successfully

[ftp] get update.bin update.bin

[ftp] bye

Step2 Upgrade Boot ROM. <HP> bootrom update file update.bin slot 1

This command will update bootrom file on the specified board(s), Continue? [Y/

N]:y

Now updating bootrom, please wait...

Step3 Load the system software image and specify the file as the main file at the next reboot. <HP> boot-loader file update.bin slot 1 main

This command will set the boot file of the specified board. Continue? [Y/N]:y

The specified file will be used as the main boot file at the next reboot on slot 1!

<HP> display boot-loader

Slot 1

Page 55: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 54

The current boot app is: flash:/update.bin

The main boot app is: flash:/update.bin

The backup boot app is: flash:/update.bin

<HP> reboot

NOTE: • You must reboot the switch with the reboot command to complete the upgrade.

Before that, save the configurations you have made to avoid data loss. • If Flash memory is insufficient, load the Boot ROM image first and delete useless files to

free up Flash memory before you load the system software image. • Avoid power failure during the loading process.

TFTP download from a server The switch can work as a TFTP client to download files from a TFTP server, and the downloading procedure is similar to downloading files through FTP. With these two protocols, the subsequent Boot ROM and system software image loading procedures are the same.

Appendix Details of Changed CLI Commands in R1211P02 ntp-service broadcast-server Syntax

ntp-service broadcast-server [ authentication-keyid keyid | version number ] *

undo ntp-service broadcast-server

View Layer 3 Ethernet port view, VLAN interface view

Default level 3: Manage level

Parameters authentication-keyid keyid: Specifies the key ID to be used for sending broadcast messages to broadcast clients, where keyid ranges from 1 to 4294967295. This parameter is not meaningful if authentication is not required.

version number: Specifies the NTP version, where number is in the range of 1 to 4 and defaults to 3.

Page 56: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 55

Description Use the ntp-service broadcast-server command to configure the device to work in the NTP broadcast server mode and use the current interface to send NTP broadcast packets.

Use the undo ntp-service broadcast-server command to remove the configuration.

By default, the device does not work in any NTP operation mode.

Examples # Configure the device to work in broadcast server mode and send NTP broadcast messages on VLAN-interface 1, using key 4 for encryption, and set the NTP version to 4. <Sysname> system-view

[Sysname] interface vlan-interface 1

[Sysname-Vlan-interface1] ntp-service broadcast-server authentication-keyid 4 version 4

ntp-service multicast-server Syntax

ntp-service multicast-server [ ip-address ] [ authentication-keyid keyid | ttl ttl-number | version number ] *

undo ntp-service multicast-server [ ip-address ]

View Layer 3 Ethernet port view, VLAN interface view

Default level 3: Manage level

Parameters ip-address: Multicast IP address, which defaults to 224.0.1.1.

authentication-keyid keyid: Specifies the key ID to be used for sending multicast messages to multicast clients, where keyid is in the range of 1 to 4294967295. This parameter is not meaningful if authentication is not required.

ttl ttl-number: Specifies the TTL of NTP multicast messages, where ttl-number is in the range of 1 to 255 and defaults to 16.

version number: Specifies the NTP version, where number is in the range of 1 to 4 and defaults to 3.

Description Use the ntp-service multicast-server command to configure the device to work in the NTP multicast server mode and use the current interface to send NTP multicast packets.

Use the undo ntp-service multicast-server command to remove the configuration.

By default, the device does not work in any NTP operation mode.

Examples # Configure the device to work in the multicast server mode and send NTP multicast messages on VLAN-interface 1 to the multicast address 224.0.1.1, using key 4 for encryption, and set the NTP version to 4.

Page 57: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 56

<Sysname> system-view

[Sysname] interface vlan-interface 1

[Sysname-Vlan-interface1] ntp-service multicast-server 224.0.1.1 version 4 authentication-keyid 4

ntp-service unicast-peer Syntax

ntp-service unicast-peer [ vpn-instance vpn-instance-name ] { ip-address | peer-name } [ authentication-keyid keyid | priority | source-interface interface-type interface-number | version number ] *

undo ntp-service unicast-peer [ vpn-instance vpn-instance-name ] { ip-address | peer-name }

View System view

Default level 3: Manage level

Parameters vpn-instance vpn-instance-name: Specifies the MPLS L3VPN to which the symmetric-passive peer belongs, where vpn-instance-name is a case-sensitive string of 1 to 31 characters. If the symmetric-passive peer is on the public network, do not specify this option.

peer-name: Host name of the symmetric-passive peer, a string of 1 to 20 characters.

authentication-keyid keyid: Specifies the key ID to be used for sending NTP messages to the peer, where keyid is in the range of 1 to 4294967295.

priority: Specifies the peer designated by ip-address or peer-name as the first choice under the same condition.

source-interface interface-type interface-number: Specifies the source interface for NTP messages. In an NTP message that the local device sends to its peer, the source IP address is the primary IP address of this interface. interface-type interface-number represents the interface type and number.

version number: Specifies the NTP version, where number is in the range of 1 to 4 and defaults to 3.

Description Use the ntp-service unicast-peer command to designate a symmetric-passive peer for the device.

Use the undo ntp-service unicast-peer command to remove the symmetric-passive peer designated for the device.

By default, no symmetric-passive peer is designated for the device.

Page 58: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 57

NOTE: • To synchronize the PE to a PE or CE in a VPN, provide vpn-instance vpn-instance-name

in your command. • If you include vpn-instance vpn-instance-name in the undo ntp-service unicast-peer

command, the command removes the symmetric-passive peer with the IP address of ip-address in the specified VPN. If you do not include vpn-instance vpn-instance-name in this command, the command removes the symmetric-passive peer with the IP address of ip-address in the public network.

Examples # Designate the device with the IP address of 10.1.1.1 as the symmetric-passive peer of the device, configure the device to run NTP version 4, and specify the source interface of NTP messages as VLAN-interface 1. <Sysname> system-view

[Sysname] ntp-service unicast-peer 10.1.1.1 version 4 source-interface vlan-interface 1

ntp-service unicast-server Syntax

ntp-service unicast-server [ vpn-instance vpn-instance-name ] { ip-address | server-name } [ authentication-keyid keyid | priority | source-interface interface-type interface-number | version number ] *

undo ntp-service unicast-server [ vpn-instance vpn-instance-name ] { ip-address | server-name }

View System view

Default level 3: Manage level

Parameters vpn-instance vpn-instance-name: Specifies the MPLS L3VPN to which the NTP server belongs, where vpn-instance-name is a case-sensitive string of 1 to 31 characters. If the NTP server is on the public network, do not specify this option.

server-name: Host name of the NTP server, a string of 1 to 20 characters.

authentication-keyid keyid: Specifies the key ID to be used for sending NTP messages to the NTP server, where keyid is in the range of 1 to 4294967295.

priority: Specifies this NTP server as the first choice under the same condition.

source-interface interface-type interface-number: Specifies the source interface for NTP messages. In an NTP message that the local device sends to the NTP server, the source IP address is the primary IP address of this interface. interface-type interface-number represents the interface type and number.

version number: Specifies the NTP version, where number is in the range of 1 to 4 and defaults to 3.

Page 59: A5800_5820X-CMW520-R1211P04 Release Notes

A5800_5820X-CMW520-R1211P04 Release Notes

Hewlett-Packard Development Company, L.P. 58

Description Use the ntp-service unicast-server command to designate an NTP server for the device.

Use the undo ntp-service unicast-server command to remove an NTP server designated for the device.

By default, no NTP server is designated for the device.

NOTE: • To synchronize the PE to a PE or CE in a VPN, provide vpn-instance vpn-instance-name

in your command. • If you include vpn-instance vpn-instance-name in the undo ntp-service unicast-server

command, the command removes the NTP server with the IP address of ip-address in the specified VPN. If you do not include vpn-instance vpn-instance-name in this command, the command removes the NTP server with the IP address of ip-address in the public network.

Examples # Designate NTP server 10.1.1.1 for the device, and configure the device to run NTP version 4. <Sysname> system-view

[Sysname] ntp-service unicast-server 10.1.1.1 version 4

© Copyright 2012 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.