Signature: Scale: Date: drg. no.: Drawn: Designed: Description: Job: Client: rev. no. +256-414-599 870 TEL First Floor Website: www. arc-engineers.com Email: [email protected]ARC ENGINEERING P.o Box 26789 Kampala, Uganda MOB +256-752-931 747 ARCHITECTS AND CIVIL ENGINEERING CONSULTANTS Opposite Hotel Equatorial Nomark Building Plot No......... Kyagwe Road +256-712-695 818 NOTES 1. All dimensions to be checked on site, written dimensions to be followed in preference to scaled dimensions. 2. All walls less than 200mm thick to be reinforced with hoop iron at every alternate course. 3. All reinforced concrete work is to be in accordance with structural engineer's details. 4. All sanitary work to be in accordance with M.O.H rules and regulations. 5. Where drain passes under building or driveway area, pipe to be of cast iron or encased in 150mm concrete. 6. All waste pipes and soil pipes are to be in ducts and the bends to have all cleaning eyes accessible from outside. 7. All windows and external glazed doors on ground floor to have burglar proofing to Architect's detail. 8. All door frames to be rebated & moulded & be full width of wall with moulded architrave to detail, provide rubber door stops to all doors. 9. Stair case and lobby doors to be self closing and half hour fire resistant 10. All internal plaster to be two coats steel float finished. 11. All manholes within building area, driveway and parking to have heavy duty air tight covers and double sealed. 12. Provide G.I. 125 x 100 rainwater down pipes and 125 x 100 G.I.box gutter with brackets etc. where shown. 13. All painting to be 3 coats. 14. Lay 1 layer of paving slabs 600 x 600 on sand along the perimeter of building. 15. Samples of fittings, materials etc. to be produced & approved before commencing work. 16. All office windows to have P.C. cills, built in P.V. Pelmet boxes & timber internal window cills & Skirtings. 17. Steel trusses/portal frames & purlins to be painted with 2 coats of oil paint. 18. Fire fighting equipment to be provided and installed by Building Fire Consultants where shown on plan. L.K As shown FEB-2014 Sheet of 02 P.o Box ..........,K'la. ................. ................. L.K AHIMBISIBWE EMMANUEL PROPOSED RESIDENTIAL BUILDING TO BE CONSTRUCTED ON PLOT 1436 , BLOCK 120 BAMBA - KITAGOBWA VILLAGE, KITAGOBWA, WAKISO DISTRICT. 20 x 150 = 3,000 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 RG 1.0m 4.0 m 1.65 m 2.65 m 3.4 m 3.9 m 1.5 m 3.2 m 10.5 m SEPTIC TANK SOAK PIT ENTRANCE / EXIT SLIDING GATE R O A D R E S E R V E L[ ]02 SITE PLAN SCALE 1:150 (On A1) N PARKING LAWN PLOT 1435 16.3 m 17.9 m 25 .0 m 19 .2 m 6.7 m 6.0 m A C C E S S R O A D PLOT 1437 CAR PORT DUCT SHWR TRAY W/C WHB SHWR TRAY W/C WHB Ceramic Tiles DINING ROOM MH MH MH MH gt gt gt W6 pv W5 pv W1 pv W3 pv W1 pv W1 pv D4 pv W6 pv W6 pv W5 pv W5 pv W1 pv W1 pv D4 pv D3 pv D2 pv D4 pv D4 pv D2 pv D2 pv D1 svp gt MH gt R O A D R E S E R V E LAWN LAWN LAWN PAVED WAY PAVED WAY PAVED WAY LAVARATORY LAVARATORY LOUNGE BEDROOM 1 KITCHEN STORE VERANDAH ENTRANCE LOBBY BEDROOM 2 VERANDAH Ceramic tiles f .f Ceramic tiles f .f Ceramic tiles f .f Ceramic tiles f .f Ceramic tiles f .f Ceramic tiles f .f Clay tiles f .f Ceramic tiles f .f Ceramic tiles f .f Clay tiles f .f Broom Finished Screed f .f 01 GROUND FLOOR PLAN
an architectural detailed plan with 4 bedrooms , lounge and kitches
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
- 230mm masonry wall on-690mm x 230mm strip footing on- well compacted earth to S.E's Details
Ground Level - 300.0 mm
Lower Entrance Level + 0.00 mm
1000 mm high M.sbalcony railingsto approval
StaircaseNo. of Risers=20@150mmNo. of Treads=19 @275mmAll to S.E's details
L[ ] 05 SECTIONScale 1:75 (On A1)
F
Upper Ground FloorLevel + 600.0 mm
Ground Level - 300.0 mm
First Floor Level+ 3600.0 mm
Ceiling Level+ 6,600.0 mm
Upper Ground FloorLevel + 600.0 mm
First Floor Level+ 3600.0 mm
Ceiling Level+ 6,600.0 mm
KITCHENKITCHENPATIO
BEDROOM
STAIRCASE
BALCONY
VERANDAH
ROOF CONSTRUCTION DETAILSRoof pitch angle 27o
IT4 Roofing Sheets on50mm x 50mm purlins on100mm x 50mm rafters on100mm x 50mm struts & ties on150mm x 75mm tie beam on75mm x 100mm wall plate To be fixed with hoop irons.225mm x 25mm fascia andbarge boards
1. All dimensions to be checked on site, writtendimensions to be followed in preference to scaleddimensions.
2. All walls less than 200mm thick to bereinforced with hoop iron at every alternatecourse.
3. All reinforced concrete work is to be inaccordance with structural engineer's details.
4. All sanitary work to be in accordance withM.O.H rules and regulations.
5. Where drain passes under building or drivewayarea, pipe to be of cast iron or encased in150mm concrete.
6. All waste pipes and soil pipes are to be inducts and the bends to have all cleaning eyesaccessible from outside.
7. All windows and external glazed doors onground floor to have burglar proofing toArchitect's detail.
8. All door frames to be rebated & moulded & befull width of wall with moulded architrave to detail,provide rubber door stops to all doors.
9. Stair case and lobby doors to be self closingand half hour fire resistant
10. All internal plaster to betwo coats steel float finished.
11. All manholes within building area, driveway andparking to have heavy duty air tight covers anddouble sealed.
12. Provide G.I. 125 x 100rainwater down pipes and 125 x100 G.I.box gutter withbrackets etc. where shown.
13. All painting to be 3 coats.
14. Lay 1 layer of paving slabs600 x 600 on sand along theperimeter of building.
15. Samples of fittings,materials etc. to be produced& approved before commencingwork.
16. All office windows to haveP.C. cills, built in P.V. Pelmetboxes & timber internal windowcills & Skirtings.
17. Steel trusses/portalframes & purlins to be paintedwith 2 coats of oil paint.
18. Fire fighting equipment tobe provided and installed byBuilding Fire Consultants whereshown on plan.
L.K
As shown
FEB-2014
Sheet of 02
P.o Box ..........,K'la.
................. .................
L.K
AHIMBISIBWE EMMANUEL
PROPOSED RESIDENTIAL BUILDING TO BE CONSTRUCTED ONPLOT 1436 , BLOCK 120 BAMBA - KITAGOBWA VILLAGE,
KITAGOBWA, WAKISO DISTRICT.
150
2,80
015
0
150
2,80
015
0
3,10
0
1503,000
1503,000
150
6,450
150
2,80
015
03,
100
6,450150
3,000150
3,000150
500 1,200 500 900250
900 500 1,200 500
D2 pv
W4-A pv
D2 pv
W4-A pv
SCALE 1:75 (On A1) GROUND FLOOR PLAN- Servant's Quaters
S.Q 1S.Q 1Ceramic tiles f.fCeramic tiles f.f
Scale 1:100 (On A1)
L[ ] FRONT ELEVATION- S.qScale 1:100 (On A1)
L[ ] TYPICAL SIDE ELEVATION- S.q
2,80
095
0
900
1,50
020
020
0
2,510
ROOF CONSTRUCTION DETAILSRoof pitch angle 27o
IT4 Roofing Sheets on50mm x 50mm purlins on100mm x 50mm rafters on100mm x 50mm struts & ties on150mm x 75mm tie beam on75mm x 100mm wall plate To be fixed with hoop irons.225mm x 25mm fascia andbarge boards