A PDMS DIFFUSION PUMP FOR ON-CHIP FLUID HANDLING IN MICROFLUIDIC DEVICES. Mark A. Eddings and Bruce K. Gale. Department of Bioengineering, University of Utah, Salt Lake City, UT. Department of Mechanical Engineering, University of Utah, Salt Lake City, UT. MicroTAS 2006, pp. 44-46. 陳睿鈞. - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
A PDMS DIFFUSION PUMP FOR ON-CHIP FLUID HANDLING IN
MICROFLUIDIC DEVICES
Mark A. Eddings and Bruce K. Gale
Department of Bioengineering, University of Utah, Salt Lake City, UT
Department of Mechanical Engineering, University of Utah, Salt Lake City, UT
MicroTAS 2006, pp. 44-46
陳睿鈞
Outline
Introduction Fabrication Results and Discussion Conclusion References
Introduction Fabrication Results and Discussion Conclusion References
Introduction Fabrication Results and Discussion Conclusion References
Flow Rate Characterization
atmp
T
t
ppPA
dt
dV 76
273
)( 12
device
Variables : p2 : feed pressure
A : diffusion area
equation :
with a CCD camera
t : thickness of the membrane
Comparing Theoretical Data With Experimental Data
Low aspect ratios and high aspect ratios. Diffusion area was changed by membrane elongation and
contact to the channel ceiling.
FEA results for membrane deflection in microchannels of aspect ratios 2 and 10
low high
Fluid Handling Fluid was easily manipulated through turns in cross
intersections and filling dead-end channels and chambers.
1
2
3
4
5
6
device
Three different fluids, red, green and blue, filling dead-end chambers.
Conclusion
The gas permeation pump provides a novel and convenient method for manipulating fluids within microfluidic devices.
Rapid dead-end channel filling and flow rates in the 200 nl·min-1 range have been demonstrated.
No need high frequency valve operation and significantly higher total chip areas.
Pumping and valving can be performed using one control line for pressure and one for the vacuum.
one control line
Marc A. Unger, 2000
three control lines
References Mark A Eddings and Bruce K Gale, “A PDMS-based gas permeation pump for
on-chip fluid handling in microfluidic devices”, J. Micromech. Microeng. 16 (2006) 2396–2402.
Marc A. Unger, Hou-Pu Chou, Todd Thorsen, Axel Scherer, Stephen R. Quake, “Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography”, SCIENCE VOL 288 7 APRIL 2000, 113-116.
D. Duffy, J. McDonald, O. Schueller, G. Whitesides, “Rapid Prototyping of Microfluidic Systems in Polydimethylsiloxane”, Anal. Chem. 70, pp. 4974-4984.
K. Hosokawa, K. Sato, N. Ichikawa, M. Maeda, “Power-free PDMS microfluidic devices for gold nanoparticle-based DNA analysis”, Lab chip 2004, Vol. 4, pp.181–185.
Daniel A. Bartholomeusz, Ronald W. Boutté, and Joseph D. Andrade, “Xurography: Rapid Prototyping of Microstructures Using a Cutting Plotter”, 2005 J. Microelectromech. Syst. 14 1364–74.