probing@hot temperature a new thermal approach to probing 

accuracy

Harald BergerWalter Seitz

Klemens ReitingerRobert Stoiber

Page 2: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Content• Introduction• Present Solutions• Thermal Approach• Measurement of Temperature and Displacement• Concept of dynamic thermal shielding (DTS)• Temperature Measurement w and w/o DTS• Feedback of DTS to wafer• Displacement Measurements w and w/o DTS• DTS in production environment• Outlook• Summary

2H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 3: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Introduction• You cannot beat physics

• probing at high temperatures generates a very high amount of heat energy

• main problem is drift of X/Y/Z position

• Detailed explanation of these values and a model to explain these drifts are well known [Berger/Seitz, SWTW 2013]

3H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 4: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Present Solutions

4

Methode Action Advantage DisadvantageOptical realignment correcting the drift very accurate; no

investmenttime consuming; thermal disbalancewhile realignment; nocontrol betweenrealignments

Pre soaking accelerates reaching a balanced situation

no investment time consuming;

Pre-heating of probecard and / or headplate

accelerates reaching a balanced situation

faster than just soaking; not onlyprobecard effected

time consuming; static, non localsolution; cost of invest

mathematical prediction

Contol of position bytemperature sensorsan math. methodes

Local, no time loss uncertainty remains (no controlling, no monitoring)

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 5: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Present Solutions

5

Methode Action Advantage DisadvantagePassive shielding prevents heat soaking

for a certain timefew investment Static, non local;

retarding but not solving

Cooling of probe card prevent heat soakingof probecard

Instant effect, no time lost; high invest

Static, non local

“thermal design” of probecard

Fit the design to hightemperature use

Intrinsic solution, noothercountermeasures

compromise to otherPC features;expensive materials; high invest

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 6: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Measurement of Temperature and Displacement

6

20

25

30

35

40

45

50

55

60

0 1 2 3 4 5 6 7 8 9 10

°C

time (min)

Process of Temperature

T1 no cooling

T2 no cooling

T3 no cooling

T1 cooling

T2 cooling

T3 cooling

‐160

‐140

‐120

‐100

‐80

‐60

‐40

‐20

00 1 2 3 4 5 6 7 8 9 10

deform

ation  (µ

m)

time (min)

Process of Displacement

cooling

no cooling

T1

T3

T2

ProbecardChuck +200°C, -0,2mm under needle

stakes Air cooling70 l/min

µm Measurement Unit

Measure baseplate

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 7: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Measurement of Temperature and Displacement

7

20

25

30

35

40

45

50

55

60

0 1 2 3 4 5 6 7 8 9 10

°C

time (min)

Process of Temperature

T1 no cooling

T2 no cooling

T3 no cooling

T1 cooling

T2 cooling

T3 cooling

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 8: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Measurement of Temperature and Displacement

8

‐160

‐140

‐120

‐100

‐80

‐60

‐40

‐20

00 1 2 3 4 5 6 7 8 9 10

deform

ation  (µ

m)

time (min)

Process of Displacement

cooling

no cooling

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 9: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Concept of dynamic thermal shielding (DTS)

9

Air entry

Air exit

Enlargement ofcooler

Fixture of DTS

Probecard Center TBD

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 10: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Temperature Measurement  w/o DTS

10H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Temperature distribution on Probecard with +165°C Chuck at rear position

Page 11: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Temperature Measurement  w/o DTS

11H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Temperature distribution on Probecard with +165°C Chuck at rear position

Page 12: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Temperature Measurement  w DTS

12H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Temperature distribution on Probecard with +165°C Chuck at rear position

Page 13: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Temperature Measurement  w DTS

13H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Temperature distribution on Probecard with +165°C Chuck center position (no delay)

Page 14: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Feedback of dynamic thermal shielding (DTS) to wafer

14H. Berger, W. Seitz, K. Reitinger, R. Stoiber

static

dynamic

T(chuck) = 175°C

Page 15: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

15H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 16: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

16H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 17: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Number of realignments necessary:

17

Dimension Probecard w/o cool shield

Probecard w cool shield

X 23 3

Y 14 6

Z 34 4

sum 71 13

H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 18: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Outlook:

• Thermal stabilizing of ceramic head will result in further improvement

• Docking of probecard has to be simplified for production

18H. Berger, W. Seitz, K. Reitinger, R. Stoiber

Page 19: a new thermal approach to probing accuracy - · PDF filea new thermal approach to probing accuracy Harald Berger ... no time loss uncertainty remains ... Measurement of Temperature

Summary:• Stable thermal equilibrium reached by cool shield

• Accuracy improved by factors

• Especially fast changes of heat source can be completely compensated

• Effort for realignment can be reduced dramatically

19H. Berger, W. Seitz, K. Reitinger, R. Stoiber