Industrial ETHERNET HIRSCHMANN Industrial ETHERNET Automation and Network Solutions DS 280 720-844-02-1203 HIRSCHMANN. The Industrial ETHERNET and CONNECTOR Company. Edition 2 Germany Hirschmann Electronics GmbH & Co. KG Automation and Network Solutions Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Postfach 1649 D-72606 Nürtingen Tel. +49-71 27-14-14 80 Fax +49-71 27-14-14 95/-14 96 E-mail: [email protected]http://www.hirschmann.com Hirschmann Competence Center Stuttgarter Straße 45-51 D-72654 Neckartenzlingen Tel. +49-71 27-14-19 81 Fax +49-71 27-14-15 51 E-mail: [email protected]http://www.hicomcenter.com China Hirschmann Electronics Pte Ltd Shangai Office Room 828, Summit Center 1088 west Yan An Road Shangai 200052 P.R. China Tel. +86-21-62 07-66 37 Fax +86-21-62 07-68 37 E-mail: [email protected]For all other countries please dial Tel. +49-7127-14-16 20 Contact address see Hirschmann Germany. Switzerland Hirschmann Electronics GmbH & Co. KG, Neckartenzlingen Zweigniederlassung Uster Seestrasse 16 CH-8610 Uster Tel. +41-1-9 05 82 82 Fax +41-1-9 05 82 89 E-mail: [email protected]France Hirschmann Electronics S.A.S. 2, rue des Charpentiers F-95330 Domont Tel. +33-1-39 35 01 00 Fax +33-1-39 35 01 02 E-mail: [email protected]UK Hirschmann Electronics Ltd. 4303 Waterside Centre Solihull Parkway Birmingham Business Park Birmingham West Midlands B37 7YN Tel. +44-1 21-3 29-50 00 Fax +44-1 21-3 29-50 01 E-mail: [email protected]Netherlands Hirschmann Electronics B.V. Pampuslaan 170 1382 JS WEESP Postbus 92 NL-1380 AB Weesp Tel. +31-2 94-4 62-5 91 Fax +31-2 94-4 62-5 54 E-mail: [email protected]Hirschmann. Solutions for communication. Spain Hirschmann Electronics S.A. Calle Trespaderne, 29 Edificio Barajas I, 2 a Planta E-28042 Madrid Tel. +34-91-7 46 17 30 Fax +34-91-7 46 17 35 E-mail: [email protected]Hungary Hirschmann Electronics Kft. Rokolya u. 1-13 H-1131 Budapest Tel. +36-1-3 49 41 99 Fax +36-1-3 29 84 53 E-mail: [email protected]USA Hirschmann Electronics Inc. 20440 Century Boulevard, Suite 150 Germantown, MD 20874 Tel. +1-2 40 6 86 23 00 Fax +1-2 40 6 86 35 89 E-mail: [email protected]Singapore Hirschmann Electronics Pte. Ltd. 2 International Business Park #11-02/03 The Strategy Singapore 609930 Tel. +65 63 16 77 97 Fax +65 63 16 77 77 E-mail: [email protected]Regarding the details in this catalog: Alterations may have been made to the product after the editorial deadline for this publication, namely 01.12.2003. The manufacturer reserves the right to alter the construc- tion and form, manufacture different shades and amend the scope of delivery during the delivery period insofar as the alterations and differences are acceptable to the Buyer while allowing for the Seller’s interests. Insofar as the seller or the manufacturer uses signs or numbers to mark the order or the ordered item, no rights may be derived from this alone. The illustrations may also contain accessories and special equipment which are not part of the mass-produced scope of delivery. Color differences are attributable to technical aspects of the printing process. This publication may also contain types and support services that are not made available/rendered in some countries. The information/details in this publication merely contain general descriptions or performance factors which, when applied in an actual situation, do not always correspond with the described form, and may be amended by way of the further development of products. The desired performance factors shall only be deemed binding if these are expressly agreed on conclusion of the contract. This catalog will be used internationally. However, comments on statutory, legal and fiscal provisions and effects only apply to the Federal Republic of Germany at the time of the editorial deadline for this publication. Please consult your pertinent seller about the provisions and effects that apply to your country, and regarding the latest binding version. DS 280 720-844 · Edition 2 · Printed in Germany · USt-IdNr.: 145355915
74
Embed
a Industrial ETHERNET - AB-MICRO · Transceiver, Hubs, Switches and Gateways for Industry Page 12 Contents Modular Industrial Switches Page 46 MS3124-4 MS2108-2 MACH 3005 MACH 3001
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Industrial ETHERNET
HIR
SC
HM
AN
NIn
du
strialETH
ERN
ETA
uto
ma
tion
an
d N
etw
ork
So
lutio
ns
DS
28
0 7
20
-84
4-0
2-1
20
3
HIRSCHMANN. The Industrial ETHERNET and CONNECTOR Company.
Alterations may have been made to the product after the editorial deadline for this publication, namely 01.12.2003. The manufacturer reserves the right to alter the construc-
tion and form, manufacture different shades and amend the scope of delivery during the delivery period insofar as the alterations and differences are acceptable to the Buyer
while allowing for the Seller’s interests. Insofar as the seller or the manufacturer uses signs or numbers to mark the order or the ordered item, no rights may be derived from
this alone. The illustrations may also contain accessories and special equipment which are not part of the mass-produced scope of delivery. Color differences are attributable
to technical aspects of the printing process. This publication may also contain types and support services that are not made available/rendered in some countries.
The information/details in this publication merely contain general descriptions or performance factors which, when applied in an actual situation, do not always correspond
with the described form, and may be amended by way of the further development of products. The desired performance factors shall only be deemed binding if these are
expressly agreed on conclusion of the contract. This catalog will be used internationally. However, comments on statutory, legal and fiscal provisions and effects only apply
to the Federal Republic of Germany at the time of the editorial deadline for this publication. Please consult your pertinent seller about the provisions and effects that apply to
your country, and regarding the latest binding version.
Port type and quantity 4 x 10BASE-TX, TP cable, RJ45 sockets 4 x 100BASE-TX, TP cable, RJ45 sockets 1 x 10BASE2, CX cable, BNC socket,1 x 10BASE-FL, MM cable, ST (BFOC) sockets,2 x 10BASE-T, TP cable, RJ45 sockets
Type RH1-TP RH2-TX RH1-CX (NAVY)
Order No. 943 639-002 943 657-002 943 701-002 More Interfaces
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 2300 m,
10 dB link budget at 850 nm,A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 3100 m,13 dB link budget at 850 nm,A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
Coaxial (CX) 0 -185 m Network size - cascadibility
Propagation equivalent TP port <-> TP port: 190 m port <-> port: 240 m Path variability value TP port <-> TP port: 4 BT port <-> port: 3BT Path delay value 92 BT (Class 2 Repeater) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 130 mA max. 270 mA max. 300 mA Service
Diagnostics LEDs (power, data, link status),signal contact/Fault relais (24 V DC / 1 A)
LEDs (power, data, link status, error),signal contact/fault relais (24 V DC / 1 A)
LEDs (power, data, link status, error),signal contact/fault relais (24 V DC / 1 A)
Redundancy
Redundancy functions redundant 24 V power supply Redundant 24 V power supply redundant 24 V power supplyAmbient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 40 mm x 125 mm x 80 mm 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 129 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 530 g 240 g 340 g Protection class IP 30 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) FM 3611 Class 1 Div 2 FM 3611 Class 1 Div 2 (3012523) FM 3810 FM 3810 (3012523) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
1716
Industrial ETHERNETRail Hubs
Rai
lFa
mil
y Product description
Description Industrial ETHERNET Rail Hub,Ethernet (10 Mbit/s),HIPER-Ring for high network availability
Port type and quantity 2 x 10BASE-FL, MM cables, ST (BFOC) sockets,3 x 10BASE-T, TP cables, RJ45 sockets
Type RH1-TP/FL
Order No. 943 613-002 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 5-pin Network size - length of cable
Twisted pair (TP) 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 2300 m,
10 dB link budget at 850 nm,A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 3100 m,13 dB link budget at 850 nm,A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
Coaxial (CX)Network size - cascadibility
Propagation equivalent TP port <-> TP port: 190 mTP port <-> F/O port: 390 mF/O port <-> F/O port: 260 m
Path variability value TP port <-> TP port: 3 BTTP port <-> F/O port: 6 BTF/O port <-> F/O port: 3 BT
Path delay valuePower requirements
Operating voltage 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 270 mA Service
Diagnostics LEDs (power, data, link status, collision)signal contact (24V DC / 1 A)
Redundancy
Redundancy functions redundant 24 V power supply, HIPER-Ring Ambient conditions
Operating temperature 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 80 mm x 140 mm x 85 mm Mounting DIN Rail 35 mm Weight 900 g Protection class IP 30 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) FM 3611 Class 1 Div 2 FM 3611 Class 1 Div 2 (3012523) FM 3810 FM 3810 (3012523) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
1918
Industrial ETHERNETRail Transceiver
Rai
lFa
mil
y Product description
Description Industrial ETHERNET media converter,10BASE-FL multimode and 10BASE-T
Industrial ETHERNET media converter,100BASE-FX-Multimode and 100BASE-TX
Industrial ETHERNET media converter 100BASE-FX-single mode and 100BASE-TX
Port type and quantity 1 x 10BASE-FL, MM cables, ST (BFOC) sockets,1 x 10BASE-T, TP cable, RJ45 socket
1 x 100BASE-FX, MM cables, SC sockets,1 x 100BASE-TX, TP cable, RJ45 socket
1 x 100BASE-FX, SM cables, SC sockets,1 x 100BASE-TX, TP cable, RJ45 socket
Type RT1-TP/FL RT2-TX/FX RT2-TX/FX-SM
Order No. 943 633-002 943 658-002 943-658-032 More Interfaces
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 2600 m,
11 dB link budget at 850 nm,A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
0 - 5000 m,8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 3400 m,14 dB link budget at 850 nm,A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 - 32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Network size - cascadibility
Propagation equivalent 100 m Path variability value 1 BT Path delay value 84 BT (Class 2 Repeater) 84 BT (Class 2 Repeater) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC Max. 105 mA max. 240 mA max. 240 mA Service
Diagnostics LEDs (power, data, link status),signal contact (24 V DC / 1 A)
LEDs (power, data, link status),signal contact (24 V DC / 1 A)
LEDs (power, data, link status),signal contact (24 V DC / 1 A)
Redundancy
Redundancy functions redundant 24 V power supply redundant 24 V power supply redundant 24 V power supplyMechanical construction
Dimensions (W x H x D) 40 mm x 134 mm x 80 mm 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 520 g 230 g 230 g Protection class IP 30 IP 20 IP 20 Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +75 °C -25 °C to +75 °C -25 °C to +75 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 1 kV (line/earth), 0.5 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) FM 3611 Class 1 Div 2 FM 3611 Class 1 Div 2 (3012532) FM 3810 FM 3810 (3012532) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15662-00HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
2120
Industrial ETHERNETRail Gateways
Rai
lFa
mil
y Product description
Description Rail Gateway for data transfer between ETHERNET and serial devices
Port type and quantity 1 x 10/100Base-T, TP cable, RJ45 socket, auto-negotiation,1 x RS232 or RS422 or RS485, Sub-D plug, 9-pin
Type RG2-1TX
Order No. 943 758-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 5-pin Network size - length of cable
Twisted pair (TP) 0 - 100 m Serial (RS232, RS422, RS485) 0 - 30 m Power requirements
Operating voltage 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 210 mA Service
Management serial interface, web interface Diagnostics LEDs (serial port, Ethernet status and device status) Configuration integrated program for serial configuration via MS Windows and UnixOther services supported IP protocols (TCP, SNMP, UDP, ARP, BOOTP, DHCP) Redundancy
Redundancy functions redundant 24 V power supplyAmbient conditions
Operating temperature 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm Weight 430 g Protection class IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 1 kV (line/earth), 0.5 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 10 V (150 kHz - 80 MHz) EMC emitted immunity
EN 55022 EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 in preparation Hazardous locations cUL 1604 Class 1 Div 2 in preparation Safety of information technology equipment cUL 60950 in preparation Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual, software, manual on CD-ROM Accessories to order separately rail power supply RPS 30, RPS 60 and RPS 120
23
HMI Router Router
MACH 3002 MACH 3002
HTTP PBX OFC HMI Eng Database HTTP Router
radio link
radio link
MACH 3005MACH 3005
HMI IP-Tel Block Controler
IP-Tel PLC Gate Way
RS2-FX/FX RS2-FX/FX
IP-Tel ABA ABS DIV
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
PLCPLC
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
RS2-FX/FX
22
Quality with a value for money.Rail switches excel not only on ETHERNET, but also on cost optimization.
Expand your horizons with Rail switches
by Hirschmann: the large cascading depth
allows a flexible planning as well as adap-
tation to the geographical conditions of
your automation solutions – the distance
between individual installation segments
may be up to 100 kilometers. Quick instal-
lation on a top hat rail, high network and
installation accessibility with HIPER-Ring
and redundant 24 V power supply – our
Rail switches have everything. There is
also an indicator contact with which the
device status can be captured extremely
easily.
We have a switch for every diverse need,
from the simplest application to the most
complex diagnostic functions, and de-
signed as a mission-critical switch from
the very beginning. How does that benefit
you? With reassuringly high network
accessibility: you will not be disturbed by
electromagnetic interference fields, high
operating temperatures, mechanical
stresses or even the interruption of a con-
nection.
• There is a specific switch for
every application in view of the
segmentation within our Rail
switch product family.
• Networks with optimum price
per port ratio: 5 and 8 port
switches without management
function.
• Network management/diagno-
sis or highly accessible net-
works: RS2 XX/XX switches
with management functions.
• For real-time, deterministic
applications there are no
alternatives to Rail switches!
RS2-16M RS2-FX/FX RS2-4TX EEC RS2-TX SPIDER 5TX
2524
Industrial ETHERNETUnmanaged Rail Switches
Rai
lFa
mil
y Product description
Description unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 5 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 5 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, MM cable, MTRJ socket
Type SPIDER 5TX RS2-5TX RS2-5TX/FX
Order No. 943 824-001 943 732-002 943 732-102 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 3-pin / no signal contact 1 plug-in terminal block, 5-pin / no signal contact 1 plug-in terminal block, 5-pin / no signal contactV.24 interfaceStandby portNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Line - / star topology any Any anyRing structure (HIPER-Ring)Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 120 mA max. 130 mA max. 180 mA Service
ManagementDiagnostics LEDs (power, link status, data, data rate, error) LEDs (power, link status, data, error) LEDs (power, link status, data, error)
ConfigurationSecurityOther services
Redundancy
Redundancy functions redundant 24 V power supply redundant 24 V power supplyAmbient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -40 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 25 mm x 100 mm x 78.5 mm 40 mm x 145 mm x 80 mm 40 mm x 145 mm x 80 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 110 g 520 g 520 g Protection class IP 30 IP 20 IP 20 Mechanical stability
IEC 60068-2-27 shock 15 g, 11 ms duration, 18 shocks 15 g, 11 ms duration, 18 shocks 15 g, 11 ms duration, 18 shocksIEC 60068-2-6 vibration 3.5 mm, 3 Hz - 9 Hz, 10 cycles, 1 octave/min.;
EN 61000-4-2 electrostatic discharge (ESD) 4 kV contact discharge, 8 kV air discharge 4 kV contact discharge, 8 kV air discharge 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 1 kV (line/earth), 0.5 kV (line/line), 1 kV data line power line: 1 kV (line/earth), 0.5 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz) 10 V (150 kHz - 80 MHz) 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) Germanischer LloydScope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
2726
Industrial ETHERNETUnmanaged Rail Switches
Rai
lFa
mil
y Product description
Description unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 4 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100Base-FX, MM cable, SC sockets
4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cable, SC sockets
3 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, MM cables, SC sockets
Type RS2-4TX/1FX RS2-4TX/1FX-SM RS2-3TX/2FX
Order No. 943 754-001 943 770-001 943 752-002 More Interfaces
Line - / star topology any any anyRing structure (HIPER-Ring)Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 200 mA max. 200 mA max. 250 mA Service
ManagementDiagnostics LEDs (power, link status, data, error),
signal contact / fault relais (24 V DC / 1 A) LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
ConfigurationSecurityOther services
Redundancy
Redundancy functions redundant 24 V power supply redundant 24 V power supply redundant 24 V power supplyAmbient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 320 g 320 g 320 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharche EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
2928
Industrial ETHERNETUnmanaged Rail Switches
Rai
lFa
mil
y Product description
Description unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 3 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, SM cables, SC sockets
8 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type RS2-3TX/2FX-SM RS2-TX RS2-4TX EEC
Order No. 943 753-002 943 686-003 943 819-001 More Interfaces
Line - / star topology any any anyRing structure (HIPER-Ring)Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC power supply (-25% to +30%) Current consumption at 24 V DC max. 250 mA max. 290 mA max. 180 mA Service
ManagementDiagnostics LEDs (power, link status, data, error),
signal contact / fault relais (24 V DC / 1 A) LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
ConfigurationSecurityOther services
Redundancy
Redundancy functions redundant 24 V power supply redundant 24 V power supply redundant 24 V power supplyAmbient conditions
Operating temperature 0 °C to +60 °C 0°C to +60°C -40 °C to +70 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -40 °C to +85 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 320 g 230 g 300 g Protection class IP 20 IP20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (linie/earth), 1 kV (linie/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
3130
Industrial ETHERNETUnmanaged Rail Switches
Rai
lFa
mil
y Product description
Description unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, MM cable, SC sockets
4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cable, SC sockets
3 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, MM cables, SC sockets
Type RS2-4TX/1FX EEC RS2-4TX/1FX-SM EEC RS2-3TX/2FX EEC
Order No. 943 773-001 943 774-001 943 771-001 More Interfaces
Line - / star topology any any anyRing structure (HIPER-Ring)Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 220 mA Max. 220 mA max. 230 mA Service
ManagementDiagnostics LEDs (power, link status, data, error),
signal contact / fault relais (24 V DC / 1 A) LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
LEDs (power, link status, data, error),signal contact / fault relais (24 V DC / 1 A)
ConfigurationSecurityOther services
Redundancy
Redundancy functions redundant 24 V power supply redundant 24 V power supply redundant 24 V power supplyAmbient conditions
Operating temperature -40 °C to +70 °C -40 °C to +70 °C -40 °C to +70 °CStorage/transport temperature -40 °C to +85 °C -40 °C to +85 °C -40 °C to +85 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 320 g 320 g 320 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
3332
Industrial ETHERNETUnmanaged Rail Switches
Rai
lFa
mil
y Product description
Description unmanaged Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 3 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, SM cables, SC sockets
Type RS2-3TX/2FX-SM EEC
Order No. 943 772-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 5-pin V.24 interfaceStandby portNetwork size - length of cable
Line - / star topology anyRing structure (HIPER-Ring)Power requirements
Operating voltage 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 230 mA Service
ManagementDiagnostics LEDs (power, link status, data, error),<br>
signal contact / fault relais (24 V DC / 1 A)
ConfigurationSecurityOther services
Redundancy
Redundancy functions fedundant 24 V power supplyAmbient conditions
Operating temperature -40 °C to +70 °CStorage/transport temperature -40 °C to +85 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 111 mm Mounting DIN Rail 35 mm Weight 320 g Protection class IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, 19" installation frame
3534
Industrial ETHERNETManaged Rail Switches
Rai
lFa
mil
y Product description
Description managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 5 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-TX, TP cables, RJ45 sockets, auto-polarity
5 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, MM cables, SC sockets
5 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, MM cables, ST (BFOC) sockets
Type RS2-TX/TX RS2-FX/FX RS2-FX/FX (ST)
Order No. 943 654-600/700 943 653-600/700 943 716-600/700 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 5-pin 1 plug-in terminal block, 5-pin 1 plug-in terminal block, 5-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socket 1 x RJ11 socketStandby port 1 x RJ45 socket 1 x RJ45 socket 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
0 - 5000 m,8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC Max. 400 mA max. 375 mA max. 375 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 850 g 850 g 850 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
Description managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch, store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 5 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, SM cables, SC sockets
5 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cable, 1300 nm, SC sockets,1 x 100BASE-FX, SM cable, 1550 nm, SC sockets
5 x 10/100Base-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100Base-FX, SM cables, 1500nm, SC sockets
Type RS2-FX-SM/FX-SM RS2-FX-SM/FX-LH RS2-FX-LH/FX-LH
Order No. 943 655-600/700 943 747-600/700 943 748-600/700 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 5-pin 1 plug-in terminal block, 5-pin 1 plug-in terminal block, 5-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socket 1 x RJ11 socketStandby port 1 x RJ45 socket 1 x RJ45 socket 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µmMultimode fiber (MM) 62.5/125 µmSingle mode fiber (SM) 9/125 µm 0 - 32.5 km,
16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
0 - 32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, CD = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km,7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
24 - 86.6 km,7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Network size - cascadibility
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 375 mA max. 375 mA max. 375 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 850 g 850 g 850 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203860) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Germanischer Lloyd (15 662 - 00 HH) Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
Description managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 16 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 15 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, MM cables, SC sockets
15 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cables, SC sockets
Type RS2-16M RS2-16M 1MM SC RS2-16M 1SM SC
Order No. 943 788-001 943 789-001 943 790-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socket 1 x RJ11 socketStandby port 1 x RJ45 socket 1 x RJ45 socket 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 5000 m, 8 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m, 11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 - 32.5 km, 16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 500 mA max. 550 mA max. 550 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 650 g 650 g 650 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation Hazardous locations cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation Safety of information technology equipmentGermanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
Description managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 15 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cables, 1550 nm, SC sockets
14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, MM cables, SC sockets
14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, MM cables, SC sockets1 x 100BASE-FX, SM-cables, SC sockets
Type RS2-16M 1LH SC RS2-16M 2MM SC RS2-16M 1MM SC/1 SM SC
Order No. 943 791-001 943 792-001 943 793-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socket 1 x RJ11 socketStandby port 1 x RJ45 socket 1 x RJ45 socket 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 5000 m, 8 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km 0 - 5000 m, 8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m, 11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
0 - 4000 m, 11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 - 32.5 km, 16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km, 7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Network size - cascadibility
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 550 mA max. 600 mA max. 600 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 650 g 650 g 650 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation Hazardous locations cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation Safety of information technology equipmentGermanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
Description managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, MM cables, SC sockets1 x 100BASE-FX, SM-cables, 1550 nm, SC sockets
14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, SM-cables, SC sockets
14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,1 x 100BASE-FX, SM cables, 1300 nm, SC sockets1 x 100BASE-FX, SM-cables, 1550 nm, SC sockets
Order No. 943 794-001 943 795-001 943 796-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socket 1 x RJ11 socketStandby port 1 x RJ45 socket 1 x RJ45 socket 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 5000 m, 8 dB link budget at 1300 nm,
A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m, 11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 - 32.5 km, 16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km
0 - 32.5 km, 16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km, 7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
24 - 86.6 km, 7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Network size - cascadibility
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 600 mA max. 600 mA max. 600 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, standby, redundancy manager),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 650 g 650 g 650 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation cUL 508 (E175531) in preparation Hazardous locations cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation cUL 1604 Class 1 Div 2 (E203960) in preparation Safety of information technology equipmentGermanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Germanischer Lloyd (15 662 - 00 HH) in preparation Scope of delivery and accessories
Scope of delivery device, terminal block, operating manual device, terminal block, operating manual device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
Description managed Industrial ETHERNET Rail Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
Port type and quantity 14 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity,2 x 100BASE-FX, SM-cables, 1550 nm, SC sockets
Type RS2-16M 2LH SC
Order No. 943 797-001 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin V.24 interface 1 x RJ11 socketStandby port 1 x RJ45 socketNetwork size - length of cable
Twisted pair (TP) 0 - 100 m Multimode fiber (MM) 50/125 µmMultimode fiber (MM) 62.5/125 µmSingle mode fiber (SM) 9/125 µmSingle mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km, 7 - 29 dB link budget at 1550 nm,
A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Network size - cascadibility
Line - / star topology anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) Current consumption at 24 V DC max. 600 mA Service
Management serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, standby, redundancy manager),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 110 mm x 131 mm x 111 mm Mounting DIN Rail 35 mm Weight 650 g Protection class IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) in preparation Hazardous locations cUL 1604 Class 1 Div 2 (E203960) in preparation Safety of information technology equipmentGermanischer Lloyd Germanischer Lloyd (15 662 - 00 HH) in preparation Scope of delivery and accessories
Scope of delivery device, terminal block, operating manualAccessories to order separately rail power supply RPS 30, RPS 60 or RPS 120, terminal cable, HiVision network management,
An invoice without any gray areas. With MICE you order only what you need.
MS2108-2
MS3124-4
MACH 3002 MACH 3002
MACH 3002MACH 3002
MACH 3002
HIPER-RingGigabit ETHERNET
HIPER-RingFast ETHERNET
Rail
RS2
RS2
RS2
MICE
MICE
MICE+RailRS2
RS2
MICE MICE
DualHoming
RedundantCoupling
DualHoming
HIPER-RingFast ETHERNET
HIPER-RingFast ETHERNET
HIPER-RingFast ETHERNET
R-VIP-T R-VIP-T
Monitor Monitor
Video over IP
R-VIP-T
Monitor
Server
Workstation
Printer
RS2
3x Monitors
3x PLC 1+PLC+2 Cameras
1x HMI1x Printer1x PLC
MICE MICE
MICE
Printer
• The modular construction is
economical: you only pay for
what you need.
• A lot of automatic features:
ETHERNET/Fast ETHERNET
recognition, auto negotiation,
autoconfiguration,
autocrossing, VLAN, RSTP,
SNTP and many more.
• Standard supported: 10BASE-T,
10BASE-FL, 100BASE-TX and
100BASE-FX.
• Connections for twisted pair
cable, multimode fiber optic
cable or single-mode fiber optic
cable, PoF, HCS, AUI and
M12 connectors.
• Operating reliability is a top
priority: heat is removed via
heat sinks.
Industry specific, flexible, economical and
future proof – expect nothing less from
your ETHERNET switches. If you want to
put together the functions and connec-
tions for your individual application in a
cost-optimized manner, it’s no problem for
the intelligent MICE modular system!
The modular platform also has a long-
term orientation: MICE switches and
media modules offer you a high degree of
flexibility and are perfectly adapted to the
increasing network demands of the future.
In addition, the platform guarantees
accessibility over a long period of time.
Commissioning is made easier by large
label fields and smart functions such as
autoconfiguration and autocrossing.
And like all industrial ETHERNET products
by Hirschmann the worldwide market
leader, all the members of our MICE
product family can be slotted onto the top
hat rail in no time, are capable of
redundant power supply and support the
HIPER-Ring. Because only installations
that run around the clock can ensure your
success.
4948
Industrial ETHERNETSwitches
MIC
E Product description
Description MICE, modularer, managed Industrial EHTERNET Switchstore and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
MICE, modularer, managed Industrial EHTERNET Switch,store and forward switching mode,Ethernet (10 Mbit/s) and Fast-Ethernet (100 Mbit/s)
expansion backplane with 2 slots for MS3124-4 MICE Switch
Port type and quantity up to 8 ports possible via media modules, 2 slots integrated in back panel (8 ports)
up to 24 ports possible via media modules,4 slots integrated on backplane (16 ports),2 additional slots via MB-2T expansion backplane (8 ports)
2 slots integrated on backplane(8 ports possible via media modules)
Type MS2108-2 MS3124-4 MB-2T
Order No. 943 717-003 943 746-001 943 733-002 More Interfaces
Power supply/signaling contact 1 plug-in terminal block, 6-pin 1 plug-in terminal block, 6-pin V.24 interface 1 x RJ11 socket 1 x RJ11 socketNetwork size - cascadibility
Line - / star topology any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 24 V DC (-25% to +30%) 24 V DC (-25% to +30%) Current consumption at 24 V DC 330 mA (not including media modules) 460 mA (not including media modules) Power consumption 8 W (not including media modules) 11 W (not including media modules) 0 WService
Management serial interface, web interface SNMP v1/v2/v3, HiVision serial interface, web interface SNMP v1/v2/v3, HiVision Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, error,
redundancy manager, ring port, LED test),signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, error, redundancy manager, ring port, LED test),
signal contact / fault relais (24 V DC / 1 A), RMON (statistics, history, alarms, events), port mirroring.
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3xprioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Redundancy
Redundancy functions HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
HIPER-Ring (ring structure), RSTP (rapid spanning tree protocol), redundantnetwork/ring coupling, dual homing, redundant 24 V power supply
Ambient conditions
Operating temperature 0 °C to +55 °C 0 °C to +60 °C 0 °C to +55 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 120 mm x 134 mm x 99 mm 275 mm x 134 mm x 140 mm 79 mm x 134 mm x 22 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 1 kg 1.9 kg 150 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery Device, terminal block, operating manual Device, terminal block, operating manualAccessories to order separately ML-MS2/MM labels, auto-configuration adapter (ACA 11),
HiVision network management, terminal cable, 19" installation frame, rail power supply RPS 30, RPS 60 or RPS 120
Description media module for MICE Switches (MS...),10BASE-T and 100BASE-TX
media module for MICE Switches (MS...),10BASE-FX multi-mode F/O
media module for MICE Switches (MS...),100BASE-FX multi-mode F/O
Port type and quantity 4 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 4 x 100BASE-FX, MM cable, MTRJ sockets 2 x 100BASE-FX, MM cable, SC sockets
Type MM2-4TX1 MM2-4FXM3 MM2-2FXM2
Order No. 943 722-001 943 721-001 943 718-001 AvailabilityNetwork size - length of cable
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 0.8 W 7 W 3.4 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +50 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 77 mm 38 mm x 134 mm x 77 mm 38 mm x 134 mm x 77 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 170 g 170 g 170 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
5352
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-FX single-mode F/O
media module for MICE Switches (MS...),10BASE-FL multi-mode F/O
media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX multi-mode F/O
Port type and quantity 2 x 100BASE-FX, SM cable, SC sockets 2 x 10BASE-FL, MM cables, ST (BFOC) sockets 2 x 100BASE-FX, MM cables, MTRJ sockets,2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type MM2-2FXS2 MM2-2FLM4 MM2-2FXM3/2TX1
Order No. 943 719-001 943 734-001 943 720-001 AvailabilityNetwork size - length of cable
10 dB link budget at 850 nm,A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
0 - 5000 m,8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 3100 m,13 dB link budget at 850 nm,A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 - 32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver)Power requirements
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 3.4 W 2.6 W 3.4 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 77 mm 38 mm x 134 mm x 77 mm 38 mm x 134 mm x 77 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 170 g 170 g 170 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1 kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
5554
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-FX multi-mode F/O, POF and HCS
media module for MICE Switches (MS...),10BASE-FL multi-mode F/O
media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX single mode F/O
Port type and quantity 2 x 100BASE-FX, MM cables, ST sockets 4 x 10BASE-FL, MM cables, ST (BFOC/) sockets 2 x 100BASE-FX, SM cables, SC sockets2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
Type MM2-2FXP4 MM3-4FLM4 MM3-2FXS2/2TX1
Order No. 943 842-001 943 760-001 943 762-001 Availability Q1 2004 Network size - length of cable
14 dB link budget at 650 nm,A = 10 dB/km, 3 dB reserve, B = 17 MHz x km
0 - 2300 m,10 dB link budget at 850 nm,A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 75 m,22 dB link budget at 650 nm,A = 160 dB/km, 3 dB reserve, B = >10 MHz x km, low-NA-POF
0 - 3100 m,13 dB link budget at 850 nm,A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
Single mode fiber (SM) 9/125 µm 0 -32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver)Power requirements
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 3,4 W 5 W 3.4 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +55 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 77 mm 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 170 g 180 g 180 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
5756
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX multi-mode F/O
media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX single mode F/O
media module for MICE Switches (MS...),100BASE-FX multi-mode F/O
Port type and quantity 2 x 100BASE-FX, MM cables, SC sockets2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
1 x 100BASE-FX, SM cables, SC sockets3 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
4 x 100BASE-FX, MM cable, SC sockets
Type MM3-2FXM2/2TX1 MM3-1FXL2/3TX1 MM3-4FXM2
Order No. 943 761-001 943 763-001 943 764-001 AvailabilityNetwork size - length of cable
Twisted pair (TP) 0 -100 m 0 -100 m Multimode fiber HCS (MM) 50/125 µmMultimode fiber POF (MM) 980/1000 µmMultimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
0 - 5000 m,8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µmSingle mode fiber (LH) 9/125 µm (long haul transceiver) 24 -86.6 km,
7 - 29 dB link budget at 1550 nm,A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Power requirements
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 3.4 W 3.4 W 7 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 180 g 180 g 180 g Protection class IP20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
5958
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX multi-mode F/O
media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX single mode F/O
media module for MICE Switches (MS...),100BASE-FX single mode F/O
Port type and quantity 3 x 100BASE-FX, MM cables, SC sockets1 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
1 x 100BASE-FX, SM cables, SC sockets3 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
4 x 100BASE-FX, SM cables, SC sockets
Type MM3-1FXM2/3TX1 MM3-1FXS2/3TX1 MM3-4FXS2
Order No. 943 839-001 943 838-001 943 838-001 AvailabilityNetwork size - length of cable
Twisted pair (TP) 0 -100 m 0 -100 m Multimode fiber HCS (MM) 50/125 µmMultimode fiber POF (MM) 980/1000 µmMultimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 -32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
0 -32.5 km,16 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver)Power requirements
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 5 W 5 W 7 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +55 °C 0 °C to +55 °C 0 °C to +55 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 180 g 180 g 180 g Protection class IP 20 IP 20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) in preparation Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
6160
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-TX and 100BASE-FX multi-mode F/O
media module for MICE Switches (MS...),100BASE-FX multi-mode F/O
media module for MICE Switches (MS...),10HDX in accordance AUI
Port type and quantity 2 x 100BASE-FX, MM cables, ST sockets2 x 10/100BASE-TX, TP cables, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity
4 x 100BASE-FX, MM cables, ST sockets 2 x AUI SUB-D 15 poles, male
Type MM3-2FXM4/2TX1 MM3-4FXM4 MM3-2AUI
Order No. 943 837-001 943 835-001 943 840-001 Availability Q1, 2004 Network size - length of cable
Twisted pair (TP) 0 -100 m 50 m Multimode fiber HCS (MM) 50/125 µmMultimode fiber POF (MM) 980/1000 µmMultimode fiber (MM) 50/125 µm 0 - 5000 m,
8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
0 - 5000 m,8 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
0 - 4000 m,11 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 3.4 W 7 W 3,5 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) SQE and DTE Power via ManagementLEDs (power, data, LED test)
Ambient conditions
Operating temperature 0 °C to +55 °C 0 °C to +55 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 118 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 180 g 180 g 180 g Protection class IP20 IP20 IP20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) in preparation Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels ML-MS2/MM labels
6362
Industrial ETHERNETModules
MIC
E Product description
Description media module for MICE Switches (MS...),100BASE-TX
media module for MICE Switches (MS...),100BASE-FX multi-mode F/O, POF and HCS
Port type and quantity 2 x 10/100BASE-TX, TP cables, M12 sockets (D code), auto-crossing, auto-negotiation, auto-polarity
2 x 100BASE-FX, MM cables, ST sockets
Type MM3-4TX5 MM3-4FXP4
Order No. 943 841-001 943 842-001 Availability Q1, 2004 Q1 2004 Network size - length of cable
Operating voltage power supply via the backplane of the MICE switch power supply via the backplane of the MICE switch Power consumption 1 W 3,4 WService
Diagnostics LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test) LEDs (power, link status, data, 100 Mbit/s, auto-negotiation, full duplex, ring port, LED test)
Ambient conditions
Operating temperature 0 °C to +55 °C 0 °C to +55 °CStorage/transport temperature -25 °C to +70 °C -25 °C to +70 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 38 mm x 134 mm x 118 mm 38 mm x 134 mm x 77 mm Mounting DIN Rail 35 mm DIN Rail 35 mm Weight 180 g 170 g Protection class IP20 IP 20 Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A FCC CFR47 Part 15 Class A EN 55022 EN 55022 Class A EN 55022 Class A Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) in preparation Germanischer Lloyd (43 109-02 HH) in preparation Scope of delivery and accessories
Scope of delivery module, operating manual module, operating manualAccessories to order separately ML-MS2/MM labels ML-MS2/MM labels
6564
Industrial ETHERNETLabelling sheet
MIC
E Product description
Description lables for MICE switches (MS2...) andMICE media modules (MM)
labels for MICE switches (MS3...)
Type ML-MS2/MM ML-MS3
Order No. 943 767-001 943 768-001 Number of labels
Labels per DIN A 4 sheet per DIN A 4 sheet: 4 labels for 2000-series switches, 12 labels for 2000/3000-series media modules
per DIN A 4 sheet: 4 labels for 3000-series switches
Scope of delivery and accessories
Scope of delivery 10 DIN A4 sheets with labels 10 DIN A4 sheets with labels
66
We do everything – Except compromise. MACH 3000 satisfies our performance and flexibility requirements.
MACH 3005 MACH 3002
R-VIP T R-VIP T
Workstation with VIP Software Server-Farm User TelephoneInterphone
Video over IP
Voice-Ethernet Gateway
R-VIP T R-VIP T
10x Telephone10x Interphone
12 x Video over IP
Voice-ETHERNET Gateway
R-VIP T
23 x User
StationMACH 3002
StationMACH 3002
StationMACH 3002
StationMACH 3002
DEPOMACH 3002
MACH 3005
Control Room – Central Station
MACH 3005
MACH 3000 thereby not only ensures our
own performance requirements but also
brings the idea of convergent networks to
the highest level: it would be difficult to
handle video, voice and data faster or
more reliably.
MACH 3000 has been leading the race for
a long time now. But we are continuously
engaged in enhancing our lead further.
The well-established safety concept of the
Hirschmann HIPER-Ring is again available
to you here with the modular Gigabit
ETHERNET switch as well. For the first
time, you can create complete industrial
networks with redundancy mechanisms
that compensate errors within a fraction
of a second. Our complete range of media
modules makes possible the problem-free
connection of legacy networks – for older
devices as well. MACH 3000 offers the
highest transmission performance, fast
changeover times in four priority classes
through the special industrial router and
simultaneously also protects your existing
investments via Layer 3 switching.
• Error protection through pas-
sive backplane.
• Basic equipment: MACH 3001,
MACH 3002 with two plug-in
slots and MACH 3005 with five
plug-in slots for modular basic
boards, media module, power
supply units and fan module.
• Flexible basic board, to be
equipped with up to four media
modules in all speeds
(10/100/1000 wire speed).
• Standards such as 802.1Q,
802.1D, 802.1p, 802.3x and
support for features such as
port trunking, port mirroring,
multicast (GMRP) and broad-
cast limiting as well as compre-
hensive safety functions.
6968
Industrial ETHERNETChassis
MAC
H 3
000 Product description
Description modular Gigabit Ethernet backbone switch with optional routing,store and forward switching mode,Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s), Gigabit Ethernet (1000 Mbit/s)
modular Gigabit Ethernet backbone switch,store and forward switching mode,Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s), Gigabit Ethernet (1000 Mbit/s)
basic board interface card for MACH 3002/3005
Port type and quantity up to 16 Gigabit ports and up to 64 Ethernet/Fast Ethernet ports up to 40 Gigabit ports and up to 160 Ethernet/Fast Ethernet portsType MACH 3002 MACH 3005 M-BASIC4
Order No. 943 675-001 943 676-001 943 679-320 More Interfaces
Line - / star topology any any anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 230/120 V AC 230/120 V ACCurrent consumption 2.8 A/4 A per M-PSU1 2.8 A/4 A per M-PSU1 Power consumption max. 500 W (using power calculator on www.hirschmann.com) max. 1100 W (using power calculator on www.hirschmann.com) 50 W (using power calculator on www.hirschmann.com) Max. thermal emission 1700 BTU/h (using power calculator on www.hirschmann.com) 3750 BTU/h (using power calculator on www.hirschmann.com) Service
Management serial interface, web interface, SNMPv1 Diagnostics LEDs (BOOT/RUN, MASTER/SLAVE, ERROR),
4 RMON groups simultaneously at each port (statistics, history, alarms, events),port mirroring
Security SNMP security, port security, VLANs 802.1Q Other services prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Protocols protocols: RFC791(IP), RFC792(ICMP), RFC793(TCP), RFC768(UDP), RFC826(ARP),RFC950 Internet standard subnetting procedure with the M-ROUTER module
Max. data rate 16 Gbit/s, 11.9 million packets per second 40 Gbit/s, 29.7 million packets per second Redundancy
Redundancy functions redundant power supply, redundant fan redundant power supply, redundant fan HIPER-Ring (ring structure), spanning tree protokoll STP 802.1D, dual homing, link aggregation
Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% 10% to 90% 10% to 90% Mechanical construction
Dimensions (W x H x D) 482.6 mm x 221 mm x 435.5 mm 482.6 mm x 443.3 mm x 435.5 mm 378 mm x 70 mm x 342 mm Rack units 5 10 Mounting 19" cabinet or table unit 19" cabinet or table unit MACH 3002 / MACH 3005 Weight 13.85 kg 22.65 kg 2.80 kg Protection class IP 30 IP 30 EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 4 kV contact discharge, 8 kV air discharge 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m 10 V/m EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage 2 kV power line, 1 kV data line 2 kV power line, 1 kV data line EMC emitted immunity
FCC CFR47 Part 15 FCC CFR 47 Part 15 FCC CFR 47 Part 15 EN 55022 EN 55022 EN 55022 Approvals
Safety of industrial control equipment cUL 508 (E175531) cUL 508 (E175531) Scope of delivery and accessories
Scope of delivery one basic device, one power supply unit, one fan plug-in, two panels, one non-heatingappliance plug (dt), terminal cable, operating manual
one basic device, one power supply unit, two fan plug-ins, six panels, one non-heating appliance plug (dt), terminal cable, operating manual
basic board, operating manual, manual on CD-ROM
Accessories to order separately HiVision network management software, auto-configuration adapter (ACA 11), fan,power supply unit
Description modular Gigabit switch with optional routing,the basic board is a fixed integrated componentstore and forward switching mode,Ethernet (10 Mbit/s), Fast Ethernet (100 Mbit/s), Gigabit Ethernet (1000 Mbit/s)
Port type and quantity up to 8 Gigabit ports and up to 32 Ethernet/Fast Ethernet portsType MACH 3001
Order No. 943 739-001 More Interfaces
Amount of module slots 4 Basic-board slotsV.24 interface 1 x RJ11 socketPower supply socket for PSU1+ redundant 24 V DC connection, PSU2 and PSU3, max. 10 A Network size - cascadibility
Line - / star topology anyRing structure (HIPER-Ring) 50 (reconfiguration time < 0.5 sec.) Power requirements
Operating voltage 230/120 V AC or 24 V DC ( -25% to +30%) Current consumption 0.9 A/1.8 A (230/120 V AC) or 7.5 A (24 V DC) Power consumption max. 220 W (using power calculator on www.hirschmann.com) Max. thermal emission 750 BTU/h (using power calculator on www.hirschmann.com) Service
Management serial interface, web interface, SNMPv1 Diagnostics LEDs: Integrated power supply unit (PSU1),
24 V DC connections (PSU2, PSU3),integrated fans (FAN1 to FAN4),integrated basic board (BOOT/RUN, MASTER/SLAVE, ERROR),4 simultaneous RMON groups at each port (statistics, history, alarms, events),port mirroring
Security SNMP security, port security, VLANs 802.1Q Other services prioritization (IEEE 802.1D/p), VLAN (802.1Q), multicast (IGMP snooping/querier, GMRP),
broadcastlimiter, SNTP (simple network time protocol), flow control IEEE 802.3x
Protocols protocols: RFC791(IP), RFC792(ICMP), RFC793(TCP),RFC768(UDP), RFC826(ARP),RFC950 Internet standard subnetting procedure with the M-ROUTER module
Max. data rate 8 Gbit/s, 5.9 million packets per second Redundancy
Redundancy functions red. 24 V DC power supply, fan, HIPER-Ring (ring structure),spanning tree protokoll STP 802.1D, dual homing, link aggregation
Ambient conditions
Operating temperature 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °CRelative humidity (non-condensing) 20% to 90% Mechanical construction
Dimensions (W x H x D) 482.6 mm x 88.1 mm x 515 mm Rack units 2 Mounting 19" cabinet or table unitWeight 8.5 kg Protection class IP 30 EMC interference immunity
EN 61000-4-2 electrostatic discharge (ESD) 4 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage 2 kV power line, 1 kV data line EMC emitted immunity
FCC CFR47 Part 15 FCC CFR 47 Part 15 EN 55022 EN 55022 Approvals
Safety of industrial control equipment cUL 508 (E175531) Scope of delivery and accessories
Scope of delivery one basic device including power supply unit and fan, three panels mounted,one non-heating appliance power plug (dt), terminal cable, manual on CD-ROM
Accessories to order separately HiVision network management software, auto-configuration adapter (ACA 11), fan,power supply unit
7372
Industrial ETHERNETMedia modules
MAC
H 3
000 Product description
Description media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
Port type and quantity 4 x 10BASE-FL, MM cables, ST (BFOC) sockets 8 x 10BASE-T/100BASE-TX, TP cable, RJ45 socket, auto-negotiation, auto-polarity 8 x 100BASE-FX, MM cable, MTRJ socketsType M-ETH 4MM-ST M-FAST 8TP-RJ M-FAST 8MM-MT
Order No. 943 704-021 943 680-001 943 681-001 Network size - length of cable
Twisted pair (TP) 0 to 100 m Multimode fiber (MM) 50/125 µm 0 - 2300 m
10 dB link budget at 850 nmA = 3 dB/km, 3 dB reserve, B = 400 MHz x km
0 - 5000 m 8 dB link budget at 1300 nmA = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m 11 dB link budget at 1300 nmA = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Power consumption 8 W (using power calculator on www.hirschmann.com) 10 W (using power calculator on www.hirschmann.com) 16 W (using power calculator on www.hirschmann.com) Service
ManagementDiagnostics LS/DA LED - link status / data, each port LS/DA LED - link status / data, each port LS/DA LED - link status / data, each portProtocolsMax. data rate 4 x 100 Mbit/s FDX 8 x 100 Mbit/s FDX 8 x 100 Mbit/s FDXAmbient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% 10% to 90% 10% to 90% Mechanical construction
Dimensions (W x H x D) 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm Mounting MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 Weight 0.21 kg 0.19 kg 0.24 kg Scope of delivery and accessories
Description media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
Port type and quantity 2 x 100BASE-FX, MM cable, SC sockets 2 x 100BASE-FX, SM cable, SC sockets 2 x 100BASE-FX, SM cable, SC socketType M-FAST 2MM-SC M-FAST 2SM-SC M-FAST 2LH-SC
Order No. 943 682-001 943 683-001 943 749-001 Network size - length of cable
8 dB link budget at 1300 nm A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 4000 m 11 dB link budget at 1300 nm A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 0 -32.5 km 16 dB link budget at 1300 nm A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver) 24 - 86.6 km 7 - 29 dB link budget at 1550 nm A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
Power requirements
Power consumption 7.5 W (using power calculator on www.hirschmann.com) 7.5 W (using power calculator on www.hirschmann.com) 7.5 W (using power calculator on www.hirschmann.com) Service
ManagementDiagnostics LS/DA LED - link status / data, each port LS/DA LED - link status / data, each port LS/DA LED - link status / data, each portProtocolsMax. data rate 2 x 100 Mbit/s FDX 2 x 100 Mbit/s FDX 2 x 100 Mbit/s FDXAmbient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% 10% to 90% 10% to 90% Mechanical construction
Dimensions (W x H x D) 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm Mounting MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 Weight 0.13 kg 0.13 kg 0.13 kg Scope of delivery and accessories
Description media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic boardof the MACH 3002/3005
Port type and quantity 2 x 1000BASE-TX, TP cable, RJ45 socket, auto-negotiation, auto-polarity 2 x 1000BASE-SX, MM cable, SC sockets 1 x 1000Base-LX, MM and SM cables, SC socketType M-GIGA 2TP-RJ M-GIGA 2SX-SC M-GIGA 1LX-SC
Order No. 943 741-001 943 684-001 943 685-001 Network size - length of cable
Twisted pair (TP) 0 to 100 m Multimode fiber (MM) 50/125 µm 2 - 500 m
8.5 dB link budget at 850 nm A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
2 - 1100 m with F/O adapter in accordance with IEEE 802.3z,8.5 link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 2 - 275 m 8.5 dB link budget at 850 nm A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
2 - 550 m with F/O adapter in accordance with IEEE 802.3z,8.5 link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 2 m - 13.75 km,8.5 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver)Power requirements
Power consumption 12 W (using power calculator on www.hirschmann.com) 10 W (using power calculator on www.hirschmann.com) 8.5 W (using power calculator on www.hirschmann.com) Service
ManagementDiagnostics LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each port LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each port LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each portProtocolsMax. data rate 1 Gbit/s FDX. 1 Gbit/s FDX. 1 Gbit/s FDXAmbient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% 10% to 90% 10% to 90% Mechanical construction
Dimensions (W x H x D) 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm Mounting MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 Weight 0.10 kg 0.14 kg 0.13 kg Scope of delivery and accessories
Description media module for installation in the MACH 3001 or the M-BASIC4 basic boardof the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
media module for installation in the MACH 3001 or the M-BASIC4 basic board of the MACH 3002/3005
Port type and quantity 2 x 1000BASE-LX, SM cable, SC socket 1 x 1000BASE-LX, SM cable, SC sockets 2 x 1000BASE-LX, SM cable, SC socketsType M-GIGA 2LX-SC M-GIGA 1LH-SC M-GIGA 2LH-SC
Order No. 943 737-001 943 742-001 943 743-001 Network size - length of cable
Twisted pair (TP)Multimode fiber (MM) 50/125 µm 2 - 1100 m with F/O adapter in accordance with IEEE 802.3z,
8.5 link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
Multimode fiber (MM) 62.5/125 µm 2 - 550 m with F/O adapter in accordance with IEEE 802.3z,8.5 link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
Single mode fiber (SM) 9/125 µm 2 m - 13.75 km,8.5 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Single mode fiber (LH) 9/125 µm (long haul transceiver) 16.6 -56.6 km5 -20 dB link budget at 1550 nmA = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm x km)
16.6 -56.6 km 5 -20 dB link budget at 1550 nm A = 0.3 dB/km, 3 dB reserve, D = 19 ps/(nm*km)
Power requirements
Power consumption 10 W (using power calculator on www.hirschmann.com) 8.5 W (using power calculator on www.hirschmann.com) 10 W (using power calculator on www.hirschmann.com) Service
ManagementDiagnostics LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each port LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each port LEDs SYNC - synchronous, LS link status, DO - data out, DI - data in, each portProtocolsMax. data rate 1 Gbit/s FDX. 1 Gbit/s FDX 1 Gbit/s FDX. Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% 10% to 90% 10% to 90% Mechanical construction
Dimensions (W x H x D) 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm 86 mm x 55 mm x 205 mm Mounting MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 MACH 3001 / M-BASIC4 Weight 0.14 kg 0.13 kg 0.14 kg Scope of delivery and accessories
Operating temperature 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% Mechanical construction
Dimensions (W x H x D) 86 mm x 55 mm x 205 mm Mounting MACH 3001 / M-BASIC4 Weight 0.10kg Scope of delivery and accessories
Scope of delivery module, operating manual
8382
Industrial ETHERNETAccessories
MAC
H 3
000 Product description
Description plug-in power supply for MACH 3002 and MACH 3005 basic devices. fan plug-in for MACH 3002 and MACH 3005 basic device,two redundant fans including monitoring unit
Type M-PSU1 M-AIR2
Order No. 943 677-001 943 678-001 More Interfaces
Voltage input non-heating appliance socketPower requirements
Operating voltage 230/120 V AC, self-adjusting 48 V DCInput frequency 47-63 HzCurrent consumption
230 V 585 W115 V 400 WActivation current typ. < 25 A at 265 V AC and cold startNominal power
230 V 585 W115 V 400 WService
Diagnostics LEDs (power P1 and P2) LEDs (FAN 1 and FAN 2) Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 90% (non condensing) 10% to 90% (non condensing) Mechanical construction
Dimensions (W x H x D) 126 mm x 71 mm x 342 mm 48 mm x 210 mm x 345 mm Mounting plug-in device Plug-in device Weight 2.26 kg 1.54 kg Scope of delivery and accessories
Scope of delivery power supply unit, operating manual and non-heating appliance plug (dt) fan, operating manual
84
Firsthand information. The GES Workgroup switch brings data processing to a cutting edge.
GES-24-PlusGES-24FX
GES-24TP Plus
GES-24TP Plus
Hub
GES-24TP Plus
Workgroup
Workgroup
Server
Workstation
Workgroup 2x Server
Workgroup
Performance characteristics such as the
optional power supply unit, the operation
of two management modules or link
aggregation, contribute to a significant
increase in the redundancy of the device.
And through continuous development,
Hirschmann offers you state-of-the-art
performance for challenging applications
of today and tomorrow.
Data is a material with a short expiration
date and should therefore be processed
as quickly, flexibly and securely as possible.
In order to obtain this reusable material
called information, a user must be able
to obtain the maximum throughput even
with complex multimedia applications.
However that is no longer all in today’s
world: standardized VLANs, data priori-
tizing and multicard functions are also as
much in demand today. To ensure that your
investment is protected, a high modularity
is also required. There is a system in the
market that satisfies all these expectations,
the GES workgroup switch.
• Three plug-in slots for optimum
extension with uplink module,
stack/uplink module as per
choice and management module.
• Up to six GES-24 TP Plus are
cascadable to one stack.
• The maximum per stack: 144 TP
10/100 or 100 Mbit/s FO ports
and with six uplink modules up
to 12 uplink ports.
• Only one management module
per stack required.
• Comprehensive management
over SNMP, standard browser,
Telnet and BootP support.
8786
Industrial ETHERNETSwitches
Wo
rkg
rou
p S
wit
ch G
ES
Product description
Description switch,store and forward switching mode,half duplex (HDX) and full duplex (FDX)
switch,store and forward switching mode,full duplex (FDX)
switch,store and forward switching mode,half duplex (HDX) and full duplex (FDX)
Port type and quantity 24 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation 24 x 100BASE-FX, MM cable, MTRJ sockets 4 x 10/100BASE-TX, TP cables, RJ45 sockets,1 x 100BASE-FX, MM cables, SC sockets
Type GES-24TP Plus GES-24FX IS1-TX/FX
Order No. 943 693-015 943 756-005 More Interfaces
V.24 interface outband management connection via V.24 outband management connection via V.24 943 738-001 Network size - length of cable
Twisted pair (TP) 0 - 100 m 0 - 100 m Multimode fiber (MM) 50/125 µm 0 - 2000 m,
6 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
0 - 2000 m,8db link budget at 1300 nm
Multimode fiber (MM) 62.5/125 µm 0 - 2000 m, 9 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
0 - 2000 m,11db link budget at 1300 nm
Network size - cascadibility
Line - / star topology any any anyPower requirements
Operating voltage min. 100 V, max. 240 V, input frequency: 47 to 63 Hz min. 100 V, max. 240 V, input frequency: 47 to 63 Hz wide-range input: 85-264 VAC 50 ... 60 HzCurrent consumption max. 80 W max. 80 W max. 2.7 WService
Security port security, VLAN port security, VLAN Other services prioritization prioritization basic filtering services in accordance with IEEE 802.1D Redundancy
Redundancy functions spanning tree,link aggregation,redundant power supply
spanning tree,link aggregation, redundant power supply
Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -40 °C to +70 °C -40 °C to +70 °C -20 °C to +80 °CRelative humidity (non-condensing) 5% to 95% 5% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 440 mm (=19") x 64 mm (=1.5 HU) x 285 mm 440 mm (=19") x 64 mm (=1.5 HU) x 285 mm 151 mm x 80 mm x 36 mm Mounting 19" cabinet or table unit 19" cabinet or table unit cable ductWeight 4.82 kg 4.82 kg 500 g Protection class IP 20 IP 20 IP 30 EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 FCC CFR47 Part 15 EN 55022 EN 55022 EN 55022 EN 55022 EMC interference immunity
EN 50082-1 EN 50082-1 EN 50082-1 EN 50082-1 Approvals
Safety of information technology equipment cUL 60950 cUL 60950 cUL, FCC Class B Scope of delivery and accessories
Scope of delivery device, operating manual device, operating manual device, operating manual, strain relief for the power cord Accessories to order separately redundant power supply GESXM-RED1 redundant power supply GESXM-RED1
8988
Industrial ETHERNETModules
Wo
rkg
rou
p S
wit
ch G
ES
Product description
Description management module for GES-24TP Plus management module for GES-24FX Fast ETHERNET fiber uplink module for GES-24TP-Plus and GES-24FX,half duplex (HDX) and full duplex (FDX)
Port type and quantity 1 x 100BASE-FX, SM cable, SC socketsType GESXM-MGMT-2G GESXM-MGMT-FX GESXM-01FX-SM
Order No. 943 693-115 943 756-115 943 693-305 More Interfaces
11 dB link budget at 1300 nm,A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Power requirements
Current consumption max. 2 W max. 2 W max. 10.6 WService
Diagnostics RMON 1-3 and 9, port mirroring RMON 1-3 and 9, port mirroring Configuration SNMP,
Telnet,WWW-Browser via HTTP,BOOTP/DHCP
SNMP,Telnet,WWW-Browser via HTTP,BOOTP/DHCP
Security VLAN (partially in accordance IEEE 802.1Q) VLAN (partially in accordance IEEE 802.1Q) Redundancy
Redundancy functions link aggregation,spanning tree protocol
link aggregation,spanning tree protocol
Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -40 °C to +70 °C -40 °C to +70 °C -40 °C to +70 °CRelative humidity (non-condensing) 5% to 95% 5% to 95% 5% to 95% Mechanical construction
Dimensions (W x H x D) 122.5 mm x 90.7 mm x 27.4 mm 122.5 mm x 90.7 mm x 27.4 mm 122.5 mm x 90.7 mm x 27.4 mm Mounting plug-in device plug-in device plug-in device Scope of delivery and accessories
Scope of delivery module module module
9190
Industrial ETHERNETModules
Wo
rkg
rou
p S
wit
ch G
ES
Product description
Description Fast ETHERNET fiber uplink module for GES-24TP-Plus and GES-24FX,half duplex (HDX) and full duplex (FDX)
Gigabit ETHERNET uplink module for GES-24TP-Plus and GES-24FX,half duplex (HDX) and full duplex (FDX)
Gigabit ETHERNET uplink module for GES-24TP-Plus and GES-24FX,half duplex (HDX) and full duplex (FDX)
Port type and quantity 2 x 100BASE-FX, MM cable, SC socket 1 x 1000BASE-LX, SM cable, SC socket 1 x 1000BASE-SX, MM cable, SC socketType GESXM-02FX-MM GESXM-GIGA-LX GESXM-GIGA-SX
Order No. 943 693 205 943 693-505 943 693-405 More Interfaces
6 dB link budget at 1300 nm,A = 1 dB/km, 3 dB reserve, B = 800 MHz x km
2 - 550 m with F/O adapter in accordance with IEEE 802.3z,3 dB link budget at 1300 nm,A = 1 dB/km, 2.5 dB reserve, B = 800 MHz x km
2 - 550 m,4 dB link budget at 850 nm,A = 3 dB/km, 2.5 dB reserve, B = 400 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 2000 m, 9 dB link budget at 1300 nm, A = 1 dB/km, 3 dB reserve, B = 500 MHz x km
2 - 550 m with F/O adapter in accordance with IEEE 802.3z,3 dB link budget at 1300 nm,A = 1 dB/km, 2.5 dB reserve, B = 500 MHz x km
2 - 275 m, 3 dB link budget at 850 nm, A = 3.2 dB/km, 2 dB reserve, B = 200 MHz x km
Single mode fiber (SM) 9/125 µm 2 - 5 km, 5 dB link budget at 1300 nm, A = 0.4 dB/km, 3 dB reserve, D = 3.5 ps/(nm x km)
Power requirements
Current consumption max. 10.6 W max. 2.4 W max. 2.4 WService
DiagnosticsConfiguration
SecurityRedundancy
Redundancy functions
Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -40 °C to +70 °C -40 °C to +70 °C -40 °C to +70 °CRelative humidity (non-condensing) 5% to 95% 5% to 95% 5% to 95% Mechanical construction
Dimensions (W x H x D) 122.5 mm x 90.7 mm x 27.4 mm 122.5 mm x 90.7 mm x 27.4 mm 122.5 mm x 90.7 mm x 27.4 mm Mounting pug-in device plug-in device plug-in device Scope of delivery and accessories
Scope of delivery module module module
9392
Industrial ETHERNETModules
Wo
rkg
rou
p S
wit
ch G
ES
Product description
Description Gigabit ETHERNET uplink module for GES-24TP-Plus and GES-24FX,half duplex (HDX) and full duplex (FDX)
stack module for connecting multiple GES-24TP Plus or GES-24FX to a stack
Port type and quantity 1 x 10/100/1000BASE-T, TP cable, RJ-45 socketType GESXM-GIGA-1T GESXM-STACK
Operating temperature 0 °C to +50 °C 0 °C to +50 °CStorage/transport temperature -40 °C to +70 °C -40 °C to +70 °CRelative humidity (non-condensing) 5% to 95% 5% to 95% Mechanical construction
Dimensions (W x H x D) 122.5 mm x 90.7 mm x 27.4 mm 122.5 mm x 90.7 mm x 27.4 mm Mounting plug-in device plug-in device Scope of delivery and accessories
Scope of delivery module stack cable (32 cm) for connecting two stack modules
9594
Industrial ETHERNETAccessories
Wo
rkg
rou
p S
wit
ch G
ES
Product description
Description redundant power supply for GES-24TP Plus and GES-24FXType GESXM-RED1
Order No. 943 693-705 Power requirements
Operating voltage 100/240 V ACInput frequency 50/60 HzCurrent consumption
230 V max. 5 A Output data
230 V max. 3.3 V DC at 30 A,max. 5 V DC at 9 A max,max. 12 V DC at 0.7 A max
Service
Diagnostics LED (power) Ambient conditions
Operating temperature 0 °C to +55 °CStorage/transport temperature -40 °C to +85 °CRelative humidity (non-condensing) 20% to 90% Mechanical construction
Dimensions (W x H x D) 222.8 mm x 91 mm x 45 mm Mounting plug-in device Weight 1800 g EMC interference immunity
EN 50082-1 EN 50082-1 EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 EN 55022 EN 55022 Approvals
Safety of information technology equipment cUL 60950 Scope of delivery and accessories
Scope of delivery power supply unit, operating manual, power cable, connection cable to switch,rack mounting set, screwdriver
97
MACH 3002
MACH 3002 MACH 3005
MACH 3005
HIPER-RingGigabit ETHERNET
HiVision
HIPER-RingFast ETHERNET
RS2FX/FX
RS2FX/FX
RS2FX/FX MICE
MICE
96
Network managementor how to work your way to success.HiVision and HiOPC for diagnosis and configuration: everything on screen, everything under control.
HiVision
• Result monitoring with con-
figurable transmission of
results by e-mail, SMS or as
a reference window.
• Integration of OEM devices over
standard MIB’s.
• OPC interface for connection to
SCADA systems.
• Port manager for easy configur-
ation of any number of connec-
tions for comprehensive load
and error analysis.
• Auto discovery for an immediate
overview of all SNMP-enabled
devices.
• Realistic representation of
devices with high-quality
graphic images.
The world of industrial data networks is
becoming increasingly more complex –
and whoever wants to maintain an overall
view of the situation needs to have an
intelligent network management system
that can keep pace with the rapid progress
in hardware and software development.
Obviously usability should not be neglected
in this regard. Diagnosis software must
therefore do more than master standards:
Hirschmann’s HiVision allows you to view
the configuration of any number of con-
nections. With this wide overview, you can
carry out comprehensive load and error
analyses yourself. The graphic, interactive
HiVision user interface as well as the
photorealistic device representation make
your work especially straightforward, easily
understandable, and other convenient
additions to the software increase the
enormous utility value during daily use.
HiOPC is a high-performance gateway
between SNMP and OPC that integrates
network management seamlessly in all
SCADA systems. All SNMP data become
available over an OPC interface.
HiOPC
9998
Industrial ETHERNETHiVision
Net
wo
rkM
anag
emen
t Product description
Description network management software license network management software license network management software license Type HiVision 6.2 PC Based Enterprise HiVision 6.2 PC Based Enterprise-Update HiVision 6.2 PC Based Industrial Line
Order No. 943 471-300 943 471-305 943 471-350 Version full version update full version Configuration
Configuration functions - autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
- autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
- autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
Diagnostics
Diagnostic functions - monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- integrated OPC Server HiControl in Windows Version:
easy integration in SCADA applications of device status and the reason for status change
- long-run monitoring with SNMP monitor include log function
- monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- integrated OPC Server HiControl in Windows Version:
easy integration in SCADA applications of device status and the reason for status change
- long-run monitoring with SNMP monitor include log function
- monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- integrated OPC Server HiControl in Windows Version:
easy integration in SCADA applications of device status and the reason for status change
- long-run monitoring with SNMP monitor include log function
Modules and supported components
Modules and components MACH 3000, GRS, Foundry Networks FastIron series, MultiMIKE, ALS/GLS, HiWay hubs and switches
Processor Pentium 200 or above (Pentium III recommended) Pentium 200 or above (Pentium III recommended) Pentium 200 or above (Pentium III recommended) RAM Linux and Windows stand-alone: at least 64 MB, 128 MB (recommended)
Windows - HP OpenView: at least 28 MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
Linux and Windows stand-alone: at least 64 MB, 128 MB (recommended) Windows - HP OpenView: at least 28 MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
Linux and Windows stand-alone: at least 64 MB, 128 MB (recommended) Windows - HP OpenView: at least 28 MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
Hard disk space 80 MB free 80 MB free 80 MB free Recommended resolution 1024 x 768 1024 x 768 1024 x 768 Network ETHERNET network with TCP/IP protocol stack ETHERNET network with TCP/IP protocol stack ETHERNET network with TCP/IP protocol stackScope of delivery and accessories
Scope of delivery printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
101100
Industrial ETHERNETHiVision
Net
wo
rkM
anag
emen
t Product description
Description network management software license network management software license network management software license Type HiVision 6.2 PC Based Industrial Line-Update HiVision 6.2 HPUX Enterprise HiVision 6.2 HPUX Enterprise-Update
Order No. 943 471-355 943 471-400 943 471-405 Version update full version update Configuration
Configuration functions - autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
- autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
- autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of Product-Specific Modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center Value Added Products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON Alarms and Events- integrated SNMP MIB Browser - easy Configuration of MACH 3000 Router Redundancy
Diagnostics
Diagnostic functions - monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- integrated OPC Server HiControl in Windows Version:
easy integration in SCADA applications of device status and the reason for status change
- long-run monitoring with SNMP monitor include log function
- monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- easy integration in SCADA applications of device status and
the reason for status change - long-run monitoring with SNMP monitor include log function
- monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- easy integration in SCADA applications of device status and
the reason for status change - long-run monitoring with SNMP monitor include log function
Browser Internet Explorer 4.0 or higher, Java runtime environment 1.3.1 is also installed
e.g. Netscape 4.7 java runtime environment on CD
e.g. Netscape 4.7 java runtime environment on CD
Supported SCADA systems OperateIT (ABB), PVSSII (ETM), iFix (Intellution), RS View (Rockwell),WinCC (Siemens), InTouch (Wonderware),all OPC AE 1.0 clients (Alarm and Event) andOPC DA 2.0 clients (Data Access)
OPC is not supported by HPUX
Hardware requirements
Processor Pentium 200 or above (Pentium III recommended) RAM Linux and Windows stand-alone: at least 64 MB, 128 MB (recommended)
Windows - HP OpenView: at least 28 MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
at least 128MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
at least 128MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
Hard disk space 80 MB free 80 MB free 80 MB free Recommended resolution 1024 x 768 1024 x 768 1024 x 768 Network ETHERNET network with TCP/IP protocol stack ETHERNET network with TCP/IP protocol stack ETHERNET network with TCP/IP protocol stackScope of delivery and accessories
Scope of delivery printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
103102
Industrial ETHERNETHiVision
Net
wo
rkM
anag
emen
t Product description
Description network management software license network management software license Type HiVision 6.2 HPUX Industrial Line HiVision 6.2 HPUX Industrial Line-Update
Order No. 943 471-450 943 471-455 Version full version update Configuration
Configuration functions - autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
- autodiscovery of all ICMP and SNMP devices. - save devices in a devicelist- export of all tables to ASCII files- import of product-specific modules. Users can build their own
modules for unknown devices.additional support: ANS Competence Center value added products
- multi-device-configuration: multiple configuration of devices, e.g. software update - multi-port-manager: multiple configuration of ports from different devices. - configuration of all Hirschmann components including network wide VLANs
and user groups.- trap history for whole network and single devices. - satus propagation seperately configurable for device, card,
port, power supplies, fans & chassis. - configuration of RMON alarms and events- integrated SNMP MIB browser - easy configuration of MACH 3000 router redundancy
Diagnostics
Diagnostic functions - monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- easy integration in SCADA applications of device status and
the reason for status change - long-run monitoring with SNMP monitor include log function
- monitoring of ICMP- and SNMP devices- detailled view of devices health - alarm and event protocol including definition of event-actions
like messagebox, eMail, SMS or start of any program - configurable status configuration - multi-port-analyzer for network wide port diagnostic and utilization control- assignment of MAC-Address to IP-Address- easy integration in SCADA applications of device status and
the reason for status change - long-run monitoring with SNMP monitor include log function
Browser e.g. Netscape 4.7 java runtime environment on CD
e.g. Netscape 4.7 java runtime environment on CD
Supported SCADA systems OPC is not supported by HPUX OPC is not supported by HPUX
Hardware requirements
ProcessorRAM at least 128MB, 256 MB (recommended)
HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
at least 128MB, 256 MB (recommended) HiVision requires approximately 50 MB free RAM. A further 200 kB of RAM are required foreach detected agent. The network management unit also requires RAM for the operatingsystem and any additional applications such as OpenView.
Hard disk space 80 MB free 80 MB free Recommended resolution 1024 x 768 1024 x 768 Network ETHERNET network with TCP/IP protocol stack ETHERNET network with TCP/IP protocol stackScope of delivery and accessories
Scope of delivery printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
printed manual (German and English) fax form for licensing CD-ROM with multilingual product version online documentation Acrobat reader and java runtime environment
105104
Industrial ETHERNETHiOPC
Net
wo
rkM
anag
emen
t Product description
Description Software licence for HiOPC network management and analysis software suite to integrateSNMP data into OPC applications.
Software licence for HiOPC network management and analysis software suite to integrateSNMP data into OPC applications. Extended functional range in comparison with HiOPCBasic, e.g. ICMP support ("ping")
Type HiOPC 1.0 Licence HiOPC Expert 3.0 Licence
Order No. 943 775-105 943 775-105 Version full version full version Configuration
Configuration functions - integrating SNMP data into OPC applications- pre-built tag databases for Hirschmann devices- auto-discovery
- integrating SNMP data into OPC applications- pre-built tag databases for Hirschmann devices- auto-discovery
Diagnostics
Supervision and Control - monitoring and operation without any knowladge of SNMP- monitoring of all status such as e.g. network status, link, power supply, fan ...- ICMP ("ping") support- SNMP trap support- dataviewer and communicator
- monitoring and operation without any knowladge of SNMP- monitoring of all status such as e.g. network status, link, power supply, fan ...- ICMP ("ping") support- SNMP trap support- dataviewer and communicator- network analyst- MIB template generator
Modules and supported components
Modules and components every SNMP and ICMP-device every SNMP and ICMP-device Software requirements
Operating system Windows NT 4.0 SP5, Windows 2000 Windows NT 4.0 SP5, Windows 2000 Minimum requirement for Hirschmann agents SNMP or ICMP SNMP or ICMPSupported SCADA systems any OPC-client application,
any OPC-client application,Wonderware inTouch,Cimplicity HMI,Intellution iFix,Siemens WinCC,Iconics,Allen Bradley RSView
Supported SCADA systems any OPC-client application,Wonderware inTouch,Cimplicity HMI,Intellution iFix,Siemens WinCC,Iconics,Allen Bradley RSView
any OPC-client application,Wonderware inTouch,Cimplicity HMI,Intellution iFix,Siemens WinCC,Iconics,Allen Bradley RSView
Hardware requirements
Processor Pentium 100 MHz minimum Pentium 100 MHz minimum RAM 64 MB RAM 64 MB RAM Hard disk space 10 MB free 10 MB free Network IEEE 802.3 compliant Ethernet networks with SNMP manageable devices IEEE 802.3 compliant Ethernet networks with SNMP manageable devicesScope of delivery and accessories
Scope of delivery to download from Internet (7MB zip), online help,evalution version of the expert version with complete functionality for one IP adress
to download from Internet (7MB zip), online help,evalution version with complete functionality for one IP adress
107106
Industrial ETHERNETPower supply
Syst
em A
cces
sori
es
Product description
Description 24 V DC DIN rail power supply unit 24 V DC DIN rail power supply unit 24 V DC DIN rail power supply unitType RPS 30 RPS 60 RPS 120
Order No. 943 662-003 943 662-001 943 662-011 More Interfaces
Voltage input 1 terminal block, 3-pin 1 terminal block, 3-pin 1 terminal block, 3-pin Voltage output 1 terminal block, 5-pin 1 terminal block, 4-pin 1 terminal block, 4-pin Power requirements
Operating voltage 230 V selector switch 230 V/115 V selector switch 230 V/115 VInput data
230 V 100 to 240 V AC; 47 to 63 Hz or85 to 375 V DC
176 to 264 V AC; 47 to 63 Hz or160 to 375 V DC
176 to 264 V AC; 47 to 63 Hz or210 to 375 V DC
115 V - 85 to 132 V AC; 47 to 63 Hz 85 to 132 V AC; 47 to 63 HzCurrent consumption
230 V max. 0,35 A at 296 V AC max. 0.7 A at 264 V AC max. 1,4 A at 264 V AC115 V - max. 1.3 A at 264 V AC max. 2,6 A at 264 V ACActivation current < 36 A at 240 V AC and cold start < 25 A at 264 V AC and cold start < 15 A at 264 V AC and cold startOutput data
Output voltage 24 V DC (-0,5%, +0,5%) 24 V DC (-1%, +5%) 24 V DC (-1%, +5%) Output current
230 V 1,3 A at 100 - 240 V AC 2.5 A at 176 - 264 V AC2.5 A at 160 - 375 V DC
5 A at 176 - 264V AC5 A at 210 - 375 V DC
115 V - 85 to 132 V AC; 47 to 63 Hz 5 A at 85 - 132 V ACService
Diagnostics LED (power, DC ON) LED (power, goes out at U out < 12 V) LED (power, goes out at U out < 12 V) Redundancy
Redundancy functions power supply units can be connected in parallel power supply units can be connected in parallel power supply units can be connected in parallelAmbient conditions
Operating temperature -10 °C to +70 °C (from 60 °C derating) -10 °C to +70 °C (from 60 °C derating) -10 °C to +70 °C (from 60 °C derating) Storage/transport temperature -25 °C to +85 °C -25 °C to +85 °C -25 °C to +85 °CRelative humidity (non-condensing) max. 95% without condensation 10 to 90 % 10 to 90 % Mechanical construction
Dimensions (W x H x D) 45 mm x 75 mm x 98 mm 50 mm x 125 mm x 103 mm 65 mm x 125 mm x 103 mm Mounting DIN Rail 35 mm DIN Rail 35 mm DIN Rail 35 mm Weight 230 g 460 g 620 g Protection class IP 20 IP 20 IP 20 EMC interference immunity
EN 50082-1 EN 61000-6-2 (includes EN 55024) EN 50082-1 EN 50082-1 EN 50082-2 EN 61000-6-2 (includes EN 55024) EN 50082-2 EN 50082-2 EMC emitted immunity
EN 50081-1 EN 50081-1 EN 50081-1 EN 50081-1 EN 50081-2 EN 50081-2 EN 50081-2 EN 50081-2 Approvals
Safety of industrial control equipment cUL 508 (E 198865) cUL 508 (E 198865) cUL 508 (E 198865) Safety of information technology equipment cUL 60950 (E 137006) cUL 60950 (E 137006) cUL 60950 (E 137006) Scope of delivery and accessories
Scope of delivery rail power supply,description and operating manual
rail power supply, description and operating manual
rail power supply, description and operating manual
109108
Industrial ETHERNETAdapter cable
Syst
em A
cces
sori
es
Product description
Description The ACA 11 auto-configuration adapter saves the configuration data of the connected switch.It enables managed switched to be easily comissioned and quickly replaced.
Terminal cable for configuring managed rails, MICE and MACH switches via the RS232 interface of the switch in connection with terminal software.
Type ACA 11 Terminal cable
Order No. 943 751-001 943 301-001 More Interfaces
To the RS232 interface on the switch RJ11 connector RJ11 connector To the RS232 interface on the PC or notebook Sub-D connector, 9-pin Power requirements
Operating voltage via the RS232 interface on the switch Service
Diagnostics writing to ACA, reading from ACA, writing/reading not OK; (display using LEDs on the switch)
dialog window on the PC or notebook
Configuration via the RS232 interface of the switch and via SNMP/Web Ambient conditions
Operating temperature 0 °C to +60 °C 0 °C to +60 °CStorage/transport temperature -25 °C to +70 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 90 mm x 27 mm x 12 mm Mounting plug-in module Weight 35 g 210 g Protection class IP 40 Cable length 31.5 cm 500 cm Mechanical stability
EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge EN 61000-4-3 electromagnetic field 10 V/m EMC emitted immunity
EN 55022 EN 55022 Approvals
Safety of industrial control equipment cUL 508 (E175531) Hazardous locations cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 1950 (E168643) Germanischer Lloyd Germanischer Lloyd (43 109-02 HH) Scope of delivery and accessories
Scope of delivery device, operating manual device, operating manual
111110
Industrial ETHERNETMounting accessories
Syst
em A
cces
sori
es
Product description
Description installation rack for 19" cabinet, 8 units wide and 4 units high
wall mounting device for fastening the mini transceiver to the wall or cabinet
Type 19" DIN Rail Adapter Wall Mounting Device for Mini Transceivers
Order No. 943 766-001 943 426-001 Mechanical construction
Dimensions (W x H x D) 481 mm (usable 427 mm) x 177 mm x 179 mm 72 mm x 10 mm x 21 mm Mounting 19" rack or cabinet wall or cabinetWeight 1 kg 100 g Scope of delivery and accessories
Scope of delivery 19" installation rack and operating manual 5 mounting device, each with 2 screws
113
112
There is no alternative to safety.The R-VIP T video system: your eyes and ears.
Location 3
Location 1
LAN
Location 2
LAN
R-VIP T
R-VIP T
R-VIP T
R-VIP T
R-VIP T
WAN
Workstation
Workstation
Camera
Workstation
Camera
Workstation
Camera
Camera
Camera
R-VIP T
More security is not a luxury but a basic
necessity wherever a lot of people come
together in confined spaces, such as air-
ports, railway stations, subways and
heavily frequented traffic thoroughfares.
On the other hand, industry wants to
monitor and document manufacturing
processes without interruption, in order to
ensure a constant product quality. And in
all these complex fields of application,
Hirschmann is laying down more stan-
dards – in the video system R-VIP T, we
have thought of everything in terms of
functionality, temperature range, con-
struction type and suitability for industry.
We have also thought about your budget:
simply use your existing data networks for
transmission of video, audio and control
signals worldwide and also make service
budget savings through audiovisual
remote maintenance.
• Local video and audio transmis-
sion over ETHERNET and global-
ly over Internet/ISDN for
reduced failure and downtime in
the manufacturing process.
• Configurable relay and telecom-
munications contact.
• 10/100 Mbit/s ETHERNET port
and RS232/RS422/RS485 data
interface for controllable cam-
eras.
• Redundant 24 V voltage supply.
• Multicast capability.
• Integrated video ring memory
and movement detection.
• Pan, tilt and zoom control.
• Web enabled.
HiOPC
115114
Industrial ETHERNETR
ail
Vide
o Product description
Description video, audio and control signal transmission via EthernetType R-VIP T
Video resolution in pixels MJPEG 704 x 576, 2CIF 704 x 288, CIF 352 x 288, QCIF 176 x 144 Frame rate
Frame rate per second up to 30 picturesMore Interfaces
LAN interface RJ-45, FastEthernet 10/100BASE-T, auto-negotiation, auto-polarityLAN data rate 10 kBit/s to 1 MBit/sVideo interface BNC, 75 Ohm, 1 VssAudio interface jack plug, 3.5 mm Audio input -32 dBm to +5.7 dBm adjustable Audio output -10 dBm to 0 dBm, 600 Ohm Serial interface RS232 / RS422 / RS485, bi-directional, SUB-D 9-pin Control connections
Control input via plug terminal block, buttons/switchesControl output (relay contact) via plug-in terminal block, max. 40 V, 0.8 A Power requirements
Operating voltage 24 V DC (19.2 to 32 V), connection option for redundant power supplyCurrent consumption 380 mA Power consumption 9.5 WService
Error signal contact configurable alarms: video, motion, power supply, switch input,Ethernet link
Redundancy
Redundancy functions power supplyAmbient conditions
Operating temperature 0 °C to +55 °CStorage/transport temperature -20 °C to +70 °CRelative humidity (non-condensing) 10% to 90% (non condensing) Mechanical construction
Dimensions (W x H x D) 47 mm x 135 mm x 128 mm Mounting DIN Rail 35 mm Weight 420 g Protection class IP 20 Mechanical stability
IEC 60068-2-27 shock 15 g (11 ms) IEC 60068-2-6 vibration 3.5 mm (3 Hz -9 Hz), 10 cycles, 1 octave/min.,
1g (9 Hz -150 Hz), 10 cycles, 1 octave/min.
EMC interference immunity
EN 61000-4-3 electromagnetic field 10 V/m (80 - 1000 MHz) EN 61000-4-4 fast transients (burst) 2 kV power line, 1 kV data line EN 61000-4-5 surge voltage Power line: 2 kV (line/earth), 1 kV (line/line), 1kV data line EN 61000-4-6 Conducted Immunity 3 V (10 kHz - 150 kHz), 10 V (150 kHz - 80 MHz) EN 61000-4-2 electrostatic discharge (ESD) 6 kV contact discharge, 8 kV air discharge EMC emitted immunity
FCC CFR47 Part 15 FCC CFR47 Part 15 Class A EN 55022 EN55022 Class A Approvals
Safety of industrial control equipment cUL508 Safety of information technology equipment cUL 60950 Scope of delivery and accessories
Scope of delivery video transmitter, CD with VIP-SW 1 decoder software, video manager software,VIPActiveX browser applet, operating manuals
Accessories to order separately decoder software, VIP-SW 4, rail power supply RPS 30, RPS 60, RPS 120
Rai
lVi
deo
Product description
Description multimedia-decoder software for Windows NT and Windows 95/98/2000/XPType VIP-SW 4
Order No. 943 713-005Technical data
Communication video, audio and data communication via ISDN, LAN (TCP/IP), GSM and modemsimultaneously
Compatibility fully compatible with ITU-T standard H.320 (or later)Image display can be switched between full screen quadrant display and
observation mode (background display)
Archiving automatic recording of video sequences and snapshots on the hard disk; log bookprovides connection history; the archived images and video sequences can be converted into common formats (e.g. AVI)
Remote control peripherals, such as e.g. pan, tilt drives can be controlled remotelyConfiguration, remote maintenance, and administration in administrator operating mode after password verificationSystem requirementsPC PC Pentium II ab 600 MHzRAM 64 MByteOperating system Windows 95/98/2000/XP/NT 4.0 or higherGraphics card PCI or AGPNetwork card standardISDN optionalSound card optional
Scope of delivery and accessories
Scope of delivery 1 CD mit Decodersoftware VIP-SW 4, Browser-Applet VIP Active X, BedienungsanleitungVIP-(A)V … und Bedienungsanleitung VIP-SW 4
Life without long cables.Transceivers by Hirschmann shorten the path to the network.
116 KTDE-V Mini-OTDE-BFOC
It is particularly in the office management
sector that the traffic control technology
and our daily industrial life are all becom-
ing increasingly networked – this is where
we have a multitude of cables. And that
not only causes us headaches, but in the
case of cables, it costs money as well.
However, there are a number of safe alter-
natives for difficult environmental condi-
tions over long distances and for the high-
est fail-safety: Hirschmann’s mini- and
standard transceivers that allow the direct
connection of PCs, workstations and
peripheral devices. In all situations where
companies cannot afford unproduct-ive
processes in the network, or cannot
afford network outages at all. Hirschmann
transceivers are designed for worst-case
conditions and satisfy the highest CE
classification and conform to the strict
guidelines as per VDE, ANSI, ISO and
IEEE. And that guarantees you the best
values for investment protection: MTBF
calculations confirm the high accessibility.
• Direct connection of terminal
devices to 10 Mbit/s CSMA/CD-
LAN as per the IEEE 802.3 stand-
ard.
• Mini transceiver for coaxial,
fiber optic or twisted pair tech-
nology.
• Standard transceivers with
‘vampire tap’.
• Externally accessible switches
for SQE/heartbeat test and sta-
tus/diagnosis LED’s, integrated
jabber protect function offer
protection for long-term net-
work accessibility.
KY
DE
EC
FL
4
UY
DE
MIK
E
MICE
TP
Mini-UTDE
Mini-OTDE
Mini-OTDE
PLC
COAX
FO
KTDE-VWork station
PLC
Work station
119118
Industrial ETHERNETTr
ansc
eive
r Product description
Description ETHERNET transceiver for coaxialtransceiver interface (AUI) in accordance with IEEE 802.3 and ISO/IEC 8802-3, coaxial interface (10BASE5) in accordance with IEEE 802.3
ETHERNET transceiver for coaxialtransceiver interface (AUI) in accordance with IEEE 802.3coaxial interface (10Base2) in accordance with IEEE 802.3can be plugged into AUI socket
ETHERNET transceiver for fiber-optictransceiver interface (AUI) in accordance with IEEE 802.3optical interface (10BASE-FL) in accordance with IEEE 802.3can be plugged into AUI socket
Port type and quantity 1 x 10BASE5, coaxial cable, vampire terminal (piercing tap) 1 x AUI port with Sub-D plug, 15-pin
1 x 10BASE2, coaxial cable, BNC socket, 1 x AUI port with Sub-D plug, 15-pin
1 x 10BASE-FL, MM cable, ST (BFOC) socket, 1 x AUI port with Sub-D plug, 15-pin
Type KTDE-V Mini-KTDE-BNC Mini-OTDE-BFOC
Order No. 943 258-001 943 331-001 943 303-022 More Interfaces
Power supply/signaling contact via AUI port via AUI port via AUI portNetwork size - length of cable
Transceiver cable (AUI cable) 0 -50 m 0 -50 m 0 -50 m Twisted pair (TP)Multimode fiber (MM) 50/125 µm 0 - 2600 m
11 dB link budget at 850 nm A = 3 dB/km, 3 dB reserve, B = 400 MHz x km
Multimode fiber (MM) 62.5/125 µm 0 - 3400 m 14 dB link budget at 850 nm A = 3.2 dB/km, 3 dB reserve, B = 200 MHz x km
Coaxial (CX) 0 -500 m 2.5 -185 m Network size - cascadibility
Propagation equivalent 205 m 210 m 100 m Power requirements
Operating voltage 10 - 16 V DC 10 - 16 V DC 11.28 -15.75 V DCCurrent consmption at 12 V DC (no signal) 250 mA 250 mA 80 mA Service
Diagnostics LEDs (power, data, collisions) LEDs (power, data, collisions, link status, APX) LEDs (power, data, collisions, link status) Ambient conditions
Operating temperature 0 °C to +50 °C 0 °C to +45 °C 0 °C to +45 °CStorage/transport temperature -25 °C to +85 °C -20 °C to +80 °C -20 °C to +80 °CRelative humidity (non-condensing) 10% to 95% 10% to 95% 10% to 95% Mechanical construction
Dimensions (W x H x D) 100 mm x 33 mm x 92 mm 44 mm x 21 mm x 100 mm 44 mm x 21 mm x 91 mm Mounting vampire terminal plug-in module plug-in module Weight 480 g 160 g 160 g Protection class IP 50 in installed state IP 50 IP 50 EMC interference immunity
EN 50082-1 EN 50082-1, EN 50082-1 EN 50082-2 EN 50082-2 EN 50082-2 EN 50082-2 EMC emitted immunity
EN 55022 EN 55022 EN 55022 EN 55022 Approvals
Hazardous locations cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) cUL 60950 (E168643) cUL 60950 (E168643) FM 3611 Class 1 Div 2 FM 3611 Class 1 Div 2 (3005636) FM 3810 FM 3810 (3005636) Scope of delivery and accessories
Scope of delivery device device device Accessories to order separately wall mounting device for mini transceiver wall mounting device for mini transceiver
121120
Industrial ETHERNETTr
ansc
eive
r Product description
Description ETHERNET transceiver for twisted pair,transceiver interface (AUI) in accordance with IEEE 802.3,twisted pair interface (10Base-T) in accordance with IEEE 802.3, auto-partitioning/reconnec-tion function, can be plugged into AUI socket
Port type and quantity 1 x 10BASE-T, TP cable, RJ45 socket,1 x AUI port with Sub-D plug, 15-pin
Type Mini-UTDE-RJ45
Order No. 943 270-002 More Interfaces
Power supply/signaling contact via AUI portNetwork size - length of cable
Operating voltage 11.28 to 15.75 V DCCurrent consmption at 12 V DC (no signal) 60 mA Service
Diagnostics LEDs (power, data, collisions, link status, APX) Ambient conditions
Operating temperature 0 °C to +50 °CStorage/transport temperature -20 °C to +80 °CRelative humidity (non-condensing) 10% to 95% Mechanical construction
Dimensions (W x H x D) 44 mm x 21 mm x 82 mm Mounting plug-in module Weight 160 g Protection class IP 50 EMC interference immunity
EN 50082-1 EN 50082-1 EN 50082-2 EN 50082-2 EMC emitted immunity
EN 55022 EN 55022 Approvals
Hazardous locations cUL 1604 Class 1 Div 2 (E203960) Safety of information technology equipment cUL 60950 (E168643) FM 3611 Class 1 Div 2 FM 3611 Class 1 Div 2 (3005636) FM 3810 FM 3810 (3005636) Scope of delivery and accessories
Scope of delivery device Accessories to order separately wall mounting device for mini transceiver
Get to know the ropes more easily.Hirschmann Competence Center: understanding technology is technology controlled.