Top Banner
Date: 09.03.14 File: SWINCC_08e.1 SIMATIC HMI Siemens AG 2007. All rights reserved. © SITRAIN Training for Automation and Industrial Solutions Sistema de Relatórios (Report Designer)
19
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.1

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Sistema de Relatórios (Report Designer)

Page 2: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.2

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Objetivos

- Relatório “Message Sequence”

- Relatório “Message Archive”

- Relatório de Valor Medido

- “Screenshot” de tela (x,y)

- Fornecedor CSV

- Documentação

- Relatório de Usuário

Page 3: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.3

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Paleta de Objetos do Report Designer

Page 4: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.4

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Report Designer

print job do Message sequence report

Nome do print job Nome do layout

F=File (Arquivo) P=Print (Impressão)RP=Report (Relatório)

Page 5: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.5

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Configurando e selecionando um “Print Job” Saída de Impressão para:-impressora-arquivo-outra impressora

Page 6: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.6

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Mensagens Online (Lista de Alarmes) usando Layout de Página

Double-click

-Aqui você defineo formato da mensagempor exemplo

Relatório

Report DesignerLayout de Página

Page 7: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.7

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

“Message Sequence Report” usando Layout de Impressora de Linhas

Impressoras usadas: matricial ou jato de tinta (laser não!), na porta paralela do servidor.

Alarm Logging

Nota: “Message Sequence Report“ deve estar selecionado na lista de inicialização do WinCC!

Page 8: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.8

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Arquivo de Mensagens 1/2

Page 9: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.9

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Arquivo de Mensagens 2/2

100\ significa que as últimas 100 mensagens serão impressas.

Page 10: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.10

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Valor Medido (Curvas) 1/4

Page 11: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.11

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Valor Medido (Curvas) 2/4

Page 12: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.12

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Valor Medido (Curvas) 3/4

Layout

Shortcut menu

Page 13: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.13

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Valor Medido (Curvas) 4/4

Menu de atalho

-Cor da Curva-Escala do eixo y

Page 14: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.14

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Valor Medido (Tabelas)

Page 15: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.15

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

“Foto” (Screenshot) de uma Área da Tela

{#pragma code("prtscrn.dll")BOOL PrtScreenPart (ULONG left, ULONG top, ULONG width, ULONG height);#pragma code()

ULONG ObenX,ObenY,Breite,Hoehe;

ObenX=GetLeft(lpszPictureName,"Control1"); ObenY=GetTop(lpszPictureName,"Control1");Breite=GetWidth(lpszPictureName,"Control1");Hoehe=GetHeight(lpszPictureName,"Control1");

PrtScreenPart (ObenX,ObenY,Breite,Hoehe+80);}

80

“Screenshot” de umaàrea específica da tela

Page 16: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.16

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Fornecedor CSV

arquivos .CSV são criados com Excel

Runtime

Page 17: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.17

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Documentação dos Dados de Configuração 1/2

Page 18: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.18

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Documentação dos Dados de Configuração 2/2

Page 19: A d swincc08_reportdesigner_pt

Date: 09.03.14File: SWINCC_08e.19

SIMATIC HMISiemens AG 2007. All rights reserved.©

SITRAIN Training for Automation and Industrial Solutions

Relatório de Usuário - Print Preview

.emf

“Hardcopy” do Objeto