Top Banner
a cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory Care & Sleep Medicine epoc ® blood analysis:
50

A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Mar 29, 2015

Download

Documents

Regan Bracey
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

a cost-effective point of care solution for the entire healthcare enterprise1

November 20101. A Patient-centred Approach. June 2009 Advance For Respiratory Care & Sleep Medicine

epoc® blood analysis:

Page 2: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Contents:

• System components• Test card analytes• Features and benefits• Sample requirements• How to perform a test• Wireless capabilities

• Operational specifications

• QC requirements• Navigating through the

reader screens• Quality Controls

Page 3: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® System

• epoc® Host Mobile Computer

• epoc® Reader

• epoc® BGEM Test Card

Page 4: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® System:

epoc® Data Manager (server-based)

Page 5: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Host Components

•Touch screen for navigation, using stylus•Barcode scanner•Battery-powered for portability

Page 6: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Test Cards: Smartcard Technology

TEST CARD - BOTTOM

Measurement region

Sensor module: sensor surface

valve

Blood waste chamber

Sealed calibrator reservoir

Sample entry port

TEST CARD - TOP

Sensor module: contact surface

Test Panel type

Bar Code

Page 7: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® BGEM Test Card Analytes

Page 8: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Test Menu – Calculated Values

Page 9: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Test Cards

• Easy to use• Room temperature storage• ~92uL WB sample• Integrated calibration and quality checks• Results in about 30 seconds after patient sample addition• Bar-coded for error-free panel identification, lot number,

expiry and inventory records• 12 analyte capacity on one test card

Page 10: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Reader Components

Page 11: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

• Host:• Integrated, modular barcode scanner

• Wireless Communication - Bi-directional communication with epoc Data Manager &

Readers via Wi-Fi and Bluetooth

• Flexible epoc Host Software:

–Reference and critical ranges by sample type

–Respiratory and vent parameters

–Automated Critical result handling

–Automated Reporting (read back)

–Operator / Patient / QC lockouts

Features

Page 12: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

• Reader:• Patient test time of ~30 seconds • Automated, internal equivalent QC• No maintenance• Offers portable or fixed functionality • A/C Power or Rechargeable Battery• Sensor electronics:

• Amperometric- measures current• Conductometric- measures conductivity• Potentiometric- measures voltage

• Bluetooth technology built-in

Features

Page 13: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

• epoc Data Management (EDM) software:• Web-based (accessible via any network)

• Manages the entire epoc system (reports, inventory management, can be interfaced)

Features

Page 14: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Sample requirements

• >92 µL sample (non-volumetric)• Whole blood

• Arterial, venous, capillary

• Syringes or evacuated tubes for sample collection• Evacuated tubes not recommended for ABGs

• Without anticoagulant or with lithium, sodium, or balanced heparin

• Must use balanced heparin if analyzing iCa

• epoc Care-Fill capillary tubes with balanced heparin (90 µL)

Page 15: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Test Process:• Scan operator ID and enter password• Insert test card into reader to start calibration (165 sec)• Data entry (scan patient ID, enter patient temp, vent data,

etc.)• Collect blood sample (whole blood from arterial, venous or

capillary sources)• Introduce sample into card (within 5 min of calibration)• View result (after 30-second test time)• Transmit result to EDM and LIS via WiFi (1-2 seconds)

Page 16: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Wireless Communication

EPOC™ Web-basedData Manager

Remote workstation

LIS / HIS Existing Wi-Fi Access Points

Page 17: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Operational Specifications

• Operation: AC or rechargeable battery• Operating temperature: 15° to 30° C• Relative humidity: 85% non-condensing• Barometric pressure: 400 – 825 mmHg• Operation on fully-charged battery: ~50

cards• Time to recharge Reader: ~4 hours

Page 18: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

QC requirements

• Verification of Newly Received Test Cards• Cards shipped to Australia with temperature monitors

• Verification of Reader Performance• When a connection between the Reader and the

Host is established, an electronic self-check is performed.

• If the connection is still established after 8 hours, the Host will disconnect from the Reader. Upon reconnect, another self-check will be performed.

• Every device is calibrated prior to specimen testing, eliminating the need for daily controls.

• External controls are run when a new lot is started and every 30 days thereafter or as required.

Page 19: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Navigating through the Reader Screens

Page 20: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Log In and Start Up Screens

• Start Up Screen –upon reset of Host (initiates program, reads files & configures software)

Page 21: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Main Reader Screen

• ‘Lock’ icon (dedicated readers always listed)• EDM Sync appears only when Host configured to EDM (exchange info)

Page 22: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Indicators

Page 23: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Navigation

• Lightly press stylus on Reader icon or list for menu

• Tap for selection

Page 24: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Reader Screen

• Print not enabled during test• Save button enabled after test complete. Info entered after test saved.• Close Reader connection button – cancel test and close connection

Page 25: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

epoc® Host Application User Interface

• Tool bar (Bottom of screen)• Screens (Bottom – Connected Readers + Open Test Record)• Multiple Pages (Upper left- Tabs. Greyed out=Not for Use)

Page 26: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Test Pages

•2nd ID•Hemodilution (hematocrit correction)

•Sample (Unknown, arterial, venous, mixed venous, cord, capillary)

•Temp (patient body temp for pH, pCO2 & pO2 corrected values)

•Test Selection (Select all, Clear all, Gases, Electrolytes)

•Test in Progress (progress bar)•Test Results (Measured, Calculated,Corrected)

Page 27: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Additional Test Information Pages

Page 28: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Additional Test Information Pages cont.

Page 29: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Screens when Running a Patient Sample

Calibration process takes approx. 165 secs

Page 30: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Screens when Running a Patient Sample cont.

Page 31: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Timing of Sample Introduction

• After calibration, message displayed to insert sample• Bar indicates time remaining• Sample must be introduced within 5mins

Page 32: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Screens when Running a Patient Sample cont.

Page 33: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Critical Values Action

• Reporting of critical range failure

• On screen at the time of event

• Simple drop-down menu• Simplifies reporting• Assures compliance• Unique feature• Requested by customer

Page 34: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Basis for epoc® Measurements

Potentiometric – Measures voltage• Ion selective electrodes

• Sodium• Potassium• Ionized calcium• pH• pCO2

• Nernst equation is used to convert the voltage into the assay values

• epoc measures either current, voltage, or conductance

Amperometric – Measures current• pO2• Glucose

Conductometric – Measures conductivity• Hematocrit

Page 35: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Quality Controls

Page 36: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Overview• Reader/Host Quality Controls

Barcode Scanner

Thermal System

Operating Environment

iQC

• Test Card Quality ControlsCard Temperature Monitors

Verification of card shipment

• External Liquid Quality Controls• What QCs do I run

• How often

• How to run controls

36

Page 37: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Reader/Host Quality Control

Barcode Scanner

Section 5.12: Barcode Scanner 37

Page 38: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Reader/Host Quality Control

Thermal System

Section 5.13: Thermal System 38

Page 39: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Reader/Host Quality Controls

Operating Environment• Temperature

Internal ambient temperature monitor

15°C – 30°C

• Atmospheric pressure

Internal barometric pressure sensor400 – 825 mmHg

• Relative humidity

Electronic QC checks leakage current

Humidity must be <85% at 30°C

Section 5.14: Operating Environment 39

Page 40: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Reader/Host Quality Controls

3 phases of Internal QC testing (iQC)

• InitialisationPerformed upon connection and at start of test

before calibration

• In-CalibrationPerformed after the calibrator is delivered to the

sensor array

•During Sample MeasurementMonitor procedure and sample integrity

Section 11.6.2: Overview of epoc System Internal QC (iQC) 40

Page 41: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Test Card Quality Controls

Section 4.2.2: Shipping Controls as shipped from Canada. 41

Card Temperature Monitors

Page 42: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Verification of Card Shipment

From each lot analyse 2 levels of fluid controls in duplicate on any verified reader.

Section 9.2.1: Verification of newly Received Test Cards 42

Page 43: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Control Fluids•Bio-Rad Liquichek Blood Gas Plus EGL

• Level 1 and Level 3• Used for BGEM

•Eurotrol BGEM• Level 1 and Level 3• Used for BGEM

•Mission Diagnostics Hematocrit• Level A and Level B• Used for Hematocrit

Section 9.2.3: Control Fluids 43

Page 44: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

FrequencyAs per verification of card shipment:

• With each shipment cards must be analysed in duplicate with 2 levels on any verified reader.

(Take average, compare to Value Assignment Datasheets)

In keeping with any accrediting

bodies, federal, state/territory

guidelines

AACB WP, AACB QC/QA Draft Guidline (April ‘10) 44

Page 45: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Precautions• Follow manufacturer's storage instructions• Allow equilibration (4 hours min)

• For Blood Gas QC• Handle fluid carefully• Once opened analyse immediately • Multiple tests only if using multiple readers

• Hematocrit QC• Not gas sensitive

45Section 9.4: Aqueous Fluid Handling

Page 46: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Procedure

Tests must be run as ‘QA test’QA test results are stored separately from Blood Test Results in epoc Data Manager.

• Shake ampoule - 5 to 10 secs• Hold at tip and at bottom with forefinger and thumb• Tap, if necessary• Snap ampoule off at neck• Immediately transfer into syringe• Transfer into test card

46Section 9.4.6: Procedure

Page 47: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Procedure (con’t)

Recommendations•1mL or 3mL sterile syringe•16-20 gauge blunt (drawing up) needles

•Draw 1mL from bottom of ampoule

•If air bubble present, do not invert syringe

47Section 9.4.7: Procedure

Page 48: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Value Assignment Datasheet

• Contain Target values, ranges.

• Never use values/ranges from pack insert

48Section 9.5: Value Assignment Datasheet

Page 49: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

External Liquid Quality Controls

Value Assignment Datasheet

49Section 9.5: Value Assignment Datasheet

Page 50: A cost-effective point of care solution for the entire healthcare enterprise 1 November 2010 1. A Patient-centred Approach. June 2009 Advance For Respiratory.

Thank you.

50